the new standard in Heat Transfer Equipment Century Series Heat Exchangers

Similar documents
Shell & Tube Heat Exchangers

Shell & Tube Heat Exchangers

Heat Transfer Equipment

Marine Heat Exchangers SALES SERVICE REPAIR

BASCO U-TUBE & TANK IMMERSION HEAT EXCHANGERS. ...world leaders in heat transfer technology

BASCO TYPE ES EXTENDED SURFACE PLATE FIN HEAT EXCHANGERS. ...world leaders in heat transfer technology

SCHMIDT- BRETTEN GASKETED PLATE HEAT EXCHANGERS

SB Series Brazed Plate Heat Exchanger Installation Manual

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

INDUSTRIAL HEAT EXCHANGERS

High Capacity Instantaneous Steam Fired Water Heater

S&T HEAT EXCHANGERS Part II: Main Parts, Conical Transitions, Shell & Heads, Nozzle Design.

SCHMIDT BRAZED PLATE HEAT EXCHANGERS. ...world leaders in heat transfer technology

A formula for success

Packaged Semi-Instantaneous Steam Fired Water Heater

COILS / INDUSTRIAL HEAT EXCHANGERS / NUCLEAR PRODUCTS / AIR COOLERS

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning

SOFTWARE DEVELOPMENT FOR MECHANICAL DESIGN OF SHELL AND TUBE HEAT EXCHANGER

Nuclear Electric Heating

IN THE MARINE INDUSTRY

Immersion Heaters. Screw Plug Immersion Heater

THE COMPANY. TECHNICAL OFFICE AND PRODUCTION UNITS. Our company has two production units:

UltraHeat Plate and Frame Heat Exchangers. Engineered for Excellence

Heat Transfer Equipment Overview Core COPYRIGHT. Types of Heat Exchangers and Their Common Applications in Oil and Gas Processing Facilities

UltraHeat Plate and Frame Heat Exchangers. Engineered for Excellence

Packaged Steam Fired Water Heater

SHELL AND TUBE HEAT EXCHANGERS FOR INDUSTRIAL ONCE-THROUGH COOLING SYSTEMS AND THE OCCURRENCE OF LEAKAGE

Full-line Product Overview

Exchangers. Air-cooled Heat. Exchangers

SECTION PLUMBING EQUIPMENT

Finned Tubular Heaters

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

A Long Experience in Energy Equipment and one Goal: The Customer s satisfaction. Heating Equipment and System

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

FM 517 San Leon, TX Toll Free: Office: (281) Fax: (281)

P-K COMPACT SEMI-INSTANTANEOUS INDIRECT WATER HEATERS

SINCE Heat Exchangers. Plate and Frame FFW AHRI. Shell and Tube W & S. Brazed FFB cat-2016-he

HEAT EXCHANGERS Maximize Thermal Efficiency with LaZerWeld Plate Heat Exchangers. For Industrial Refrigeration

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI.

Hard-hitting Contenders In HVAC Fluid Handling Solutions

Safario Cooling Factory LLC

Explosion-proof Immersion Heater Type D-8660

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y LS BARGE PUMP. Vertical high-flow pump

Module 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

Circulation Heaters Selection Guidelines

MECHANICAL. Product Index Mechanical Product Index

ENERGY, OIL & GAS. astsensors.com macrosensors.com. Transducer & Transmitter Capabilities. Your sensor business partner...

PLATE HEAT EXCHANGERS BETTER BY DESIGN

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Polaris PHEs vs. Shell-and-Tube Exchangers

SECTION AIR COILS

FOR THE PETROLEUM AND RELATED INDUSTRIES

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

ACCU-THERM PLATE HEAT EXCHANGER

Company Info. Quality. Personnel. Cartridge Heaters Strip Heaters. Screw Plugs Heated Tanks. Duct Heaters Flanged Heat. Blower Packages Pump Systems

Goulds 3600 Between-Bearing, Axially-Split, Multi-Stage Pumps. Goulds Pumps

DOLPHIN FRESH WATER SHELL AND TUBE EVAPORATOR

ALLEGHENY BRADFORD CORPORATION

Waste-heat recovery: Weighing in the environmental Factor

DUKE UNIVERSITY DESIGN GUIDELINES

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

SECTION HEATING BOILER FEEDWATER EQUIPMENT

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

APPLICATIONS FOR HVAC SYSTEMS

Checklist Selecting the Proper Flanged Heater

D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

Products & Application

4 route 147, C.P.33 Coaticook, Qc J1A 2S8

University of Delaware

Alfa Laval spiral heat exchangers

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

SHELL AND TUBE HEAT EXCHANGER (STHE) - part b

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

Flanged Immersion Heaters

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

Goulds 3600 Between-Bearing, Axially-Split, Multistage Pumps

Flanged Immersion Heaters

SECTION METERS AND GAGES FOR PLUMBING PIPING

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Flanged Immersion Heaters

First Line of Safety: Farris Engineering

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

STEAM VALVE SUPPLY & SYSTEM DESIGN

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. Open Impeller ASME (ANSI) B73.1 Pump for continuous use in Chemical Process Services

.2 Section Waste Management and Disposal..5 Section Performance Verification of Mechanical Piping Systems.

Secure hydraulic system performance. Smart solutions for cooling and cleaning hydraulic oil

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

DESIGN STANDARDS SECTION 15600

Transcription:

the new standard in Heat Transfer Equipment Century Series Heat Exchangers Pre-engineered & custom-engineered heat exchangers, designed to TEMA specs.

Century Series HEAT Exchangers Design flexibility As the recognized leader in heat exchanger products, systems and technology, ITT Standard has been providing state-of-the-art solutions to heat transfer The Century Series the flexible answer to heat transfer problems. Flexible in design, Century heat exchangers are capable of handling high pressures and temperatures, as well as a wide variety of fluids and gases. Based on a mechanically straightforward design, they offer a virtually limitless array of choices in terms of performance, materials, options and features. ITT Standard is headquartered in one of the largest and best-supported heat exchanger centers in the world. problems for more than 75 years. Century heat exchangers combine choice of options and control of custom design with economies of standardization and production, to give you the precise heat exchanger ITT Century Series heat exchangers are manufactured with the highest standards of quality. ITT Standard was the first North American heat exchanger manufacturer to be certified under ISO 9001 procedures and guidelines. Today, the company is devoted exclusively to the design, engineering and manufacture of shell-andtube, gasketed plate, brazed plate and air-cooled heat exchanger products. ITT Standard heat exchangers are engineered and manufactured by experienced craftsmen who have been devoted to the science of heat transfer not just for years, but for generations. And because we offer such a wide assortment of different heat exchanger designs, we can assure you of getting the optimum heat transfer solution to your specific application, without bias toward any one particular (or proprietary) you need at the lowest cost. Century series heat exchangers can be designed and manufactured to the standards and guidelines of the following: TEMA (Tubular Equipment Manufacturers Association), ASME (American Society of Mechanical Engineers), API (American Petroleum Institute), ABS (American Bureau of Shipping), The Pressure Equipment Directive (97/23/EC), USN (U.S. Navy) and others. At ITT Standard, we work directly with these organizations, and frequently offer our facilities particularly our advanced thermal research laboratory along with our expertise to help set, clarify and implement standards that contribute to the overall strength of the heat transfer industry. Design EXPERIENCE Custom-design flexibility with off-the-shelf economy. The continuous flow of design innovations and refinements, the availability of a variety of new construction materials, and an expanding array of non-traditional applications have made the task of heat exchanger selection more complex than ever before. Engineers are increasingly finding answers to these challenges in the Century series heat exchangers from ITT Standard. This line of products offers a vast range of combinations Our design staff and computerized selection process will help you choose the best heat exchanger for your application. Century Series heat exchangers are manufactured with rugged construction for tough day-to-day operations. product line. in design, performance, materials and options for virtually any heat transfer problem. Whatever the application requires, chances are there s a Century series heat exchanger that s right for the job: Fixed or floating tubesheet, single- or multi-pass, straight or U-tube, fixed tubesheet or removable bundle Steel or stainless, copper or bronze, nickel or exotic alloys, Hastelloy, Monel or titanium High standards of quality are found in every aspect of manufacturing, packaging and shipping. 2 3

CENTURY CPK Series 1 2 1) 2) 3) Shell Carbon steel with a wide variety of nozzle orientations Baffles Carbon steel or brass. Closely fitted to shell and around tubes Tubes Materials: Admiralty, copper, Cu Ni, aluminum brass, carbon steel, stainless steel 3 4 Straight tube, removable bundle, packed floating tubesheet. Single or two pass tube arrangements for maximum efficiency over a wide variety of tube side flow rates. Standard shell sizes from 3 inches through 31 inches in diameter; custom designs up to 60 inches in diameter. Available in horizontal and vertical installations as well as stacked assemblies. Century CPK Standard Design Capabilities TEMA Type AEW or BEW. Can meet TEMA B, C and R, ASME Section VIII Div. 1 U stamp and Floating tubesheet allows differential expansion between the shell and tubes. Maximum tube count per shell diameter. Shell side can be steam or mechanically cleaned. Diameter: 3/8, 5/8, 3/4, 1 Tube pitch: Triangular, square or rectangular. Tubes can be bare or Low-Fin Bundle can be easily replaced or repaired. 4) Tubesheet Carbon steel, Muntz metal, cupro-nickel, naval brass, stainless steel Heat Exchanger SELECTION Selecting the right heat exchanger. Shell Less costly than full internal floating head type construction. Your ITT Standard representative has complete information on Century series and other heat exchanger products to help you meet your particular application requirements. The latest industry standards and computer technology help us provide the most accurate heat transfer calculations. We can use commercial heat transfer programs such as BJAC and HTRI, or programs based upon research from our own heat transfer laboratory for complete, accurate and timely heat transfer ratings. Channel Cover Gasket Channel Packing Rings Floating Tubesheet Telltale Holes Lantern Gland Externally Sealed Floating Tubesheet Both shell side and tube side exposed to packing. Volatile and/or toxic fluids should be avoided. Our advanced thermal research lab is one of the largest and best equipped facilities in the industry. Staffed by a team of experienced chemical, mechanical and metallurgical engineers, it is used to solve heat transfer problems and identify opportunities for product improvement and development. It is also made available to industry groups, to develop standards and guidelines for product design, manufacturing and testing. Century CPK Type AEW Packing limits design pressure and temperature for both shell and tube sides. 4 5 www.ittstandard.com

CENTURY C100 CENTURY C200 C210 TEMA Type AEP or BEP. Can meet TEMA B, C and R, Floating tubesheet allows differential expansion between the shell and tubes. Shell side can be steam or mechanically cleaned. Bundle can be easily repaired or replaced. Less costly than full internal floating head-type construction. Straight tube, removable bundle, outside-packed floating head. Single- or multi-pass tube arrangements for maximum efficiency over a wide variety of tube side flow volumes. Standard shell sizes from 8 inches through 42 inches in diameter; custom designs up to 60 inches in diameter. Available for horizontal or vertical mounting. Century C100 Standard Design Capabilities Straight tube, fixed tubesheet, removable channel or bonnet (C200) or integral channel (C210). Single-or multi-pass tube arrangements for maximum efficiency over a wide variety of tube side flow volumes. An expansion joint can be added to compensate for severe temperature differentials. Standard shell sizes from 5 inches through 42 inches in diameter; custom designs up to 60 inches in diameter. Available for horizontal or vertical mounting. Century C200 and C210 Standard Design Capabilities TEMA Type AEM, BEM or NEN. Can meet TEMA B, C and R, Less costly than removable bundle exchangers. Provides maximum heat transfer surface area per given shell and tube size. Easily interchangeable with designs of various other manufacturers. Tube side can be steam or mechanically cleaned. Only shell side fluids are exposed to packing. Volatile or toxic fluids possible on tube side. Provides large bundle entrance area. Shell side limited to non-volatile and/or non-toxic fluids. Shell side packing limits design pressure and temperature. Century C100 type BEP Outside packed floating head detail Fixed tubesheet detail Century C200 Type BEM Only tube side fluids are exposed to gaskets. Volatile or toxic fluids possible on shell side. Easy accessibility for tube side cleaning and inspection. No packed joints. No provision for differential expansion of tubes and shell without expansion joint. Shell side can be cleaned by chemical means only. Less surface per given shell and tube size than TEMA type AEW or BEW designs. 6 7 www.ittstandard.com

CENTURY C300 C320 CENTURY C400 TEMA Type AEU or BEU. Can meet TEMA B, C and R, U-tube, removable bundle (C300) or suction-heater (open-end shell) construction (C320). Multi-pass tube arrangements for maximum efficiency over a variety of tube side flow volumes. The C320 is much like the C300, but has an open-end shell and special tube layout for tank suction heating applications. Straight tube, internally bolted floating head, pull-through construction with removable bundle. Multi-pass tube arrangements for maximum efficiency over a wide variety of tube side flow volumes. Standard shell sizes from 8 inches through 42 inches in diameter; custom designs up to 60 inches in diameter. TEMA Type AET or BET. Can meet TEMA B, C and R, Standard shell sizes from 5 inches through 42 inches in diameter; custom designs up to 60 inches in diameter. Allows for differential thermal expansion between shell and tubes, as well as between individual tubes. High heat transfer surface area for given shell and tube size. Capable of withstanding thermal shock. The most economical of all shell-and-tube exchangers, and the least expensive of all basic designs. Available for horizontal or vertical mounting. Century C300 and C320 Standard Design Capabilities Century C400 Standard Design Capabilities Bundle can be removed from shell for cleaning or maintenance. Lack of packed joints allows for handling volatile or toxic fluids. Large bundle entrance area. Allows for differential thermal expansion between shell and tubes. Bundle can be pulled without removing floating head cover. Shell side can be steam or mechanically cleaned. Bundle can be removed for shell side cleaning and maintenance. Individual tube replacement is difficult. Cannot be made single-pass on tube side, so true countercurrent flow is not possible. Stationary tubesheet detail Century C300 Type BEU Century C400 Type AET Internal bolted floating head detail Less heat transfer surface area for given shell and tube size than other removable bundle designs. The costliest of all basic types of heat exchanger designs. Gasket leak detection not possible on floating head. Draining tube side is difficult in vertical (head-up) position. Tube side can be cleaned by chemical means only. 8 9 www.ittstandard.com

CENTURY C500 CENTURY SERIES HEAT EXCHANGERS TEMA Type AES or BES. Can meet TEMA B, C and R, Higher heat transfer surface area per given shell and tube size than pull-through designs (AET or BET Types). Allows for differential thermal expansion between the shell and tubes. Lack of packed joints allows for handling volatile and/or toxic fluids. Provides multi-pass tube arrangements. Bundle can be removed for shell side cleaning and maintenance. Shell cover, clamp ring and floating head cover must be removed prior to removing bundle. This results in higher maintenance cost compared to pull-through designs (AET or BET). More costly than fixed tubesheet and U-tube designs. Straight tube, internal clamp split ring, floating head, removable bundle. Multi-pass tube arrangements for maximum efficiency over a wide variety of tube side flow volumes. Standard shell sizes from 6 inches through 42 inches in diameter; custom designs up to 60 inches in diameter. Available for horizontal or vertical mounting. Century C500 Standard Design Capabilities Century C500 Type AES Internal clamp split ring floating head detail Century series heat exchangers are available with a wide range of custom features, design variations, special materials and options to meet virtually any heat transfer requirement. Drawing on more than 75 years of thermal and mechanical design experience and heat transfer expertise, ITT Standard engineers have developed an unequalled range of choices to help you select the precise heat exchanger you need to meet your specific requirements. MATERIALS Standard designs Shells Steel, 304SS, 316SS, 304LSS, 316LSS up to 42-inch diameter. Bonnets/channels Steel, 304SS, 316SS, 304LSS, 316LSS, Cast Iron, Cast Bronze, Ductile Iron. Tubesheets Aluminum Bronze, 90/10 Cu Ni, Muntz, RNB, 304SS, 316SS, 304LSS, 316LSS, Steel. Tubes Carbon Steel, Stainless Steel, Nickel and Nickel Alloys, Titanium and other Alloys. Bare and Lo-Fin Tubing. Capabilities Hydraulic tube expansion Seal and strength welding of tubes to tubesheet Expansion joints (flanged and flued head as well as bellows type) Surface finish analysis Heat transfer test laboratory (4,000 ft2) Helium leak testing Radiographic, ultrasonic and magnetic particle testing (sub-contracted) API oil flushing design capabilities Custom designs Materials Stainless steel(s) (including Alloy 20, 317SS, AL6XN, 904LSS, etc.) Hastelloy Titanium Monel 90/10 CuNi 70/30 CuNi Inconel Incoloy Avesta 254SMO (Note: Weld qualifications may have to be developed.) Diameter Up to 42 inches for standard designs; custom designs up to 60 inches. Length Up to 30 feet for standard steel designs and 21 feet for standard stainless steel designs; custom designs up to 40 feet. Temperature From -20º F (-29º C) up to 650º F (343º C) with standard designs; custom designs from -300º F (-184º C) up to 1000º F (538º C). Weight 30 tons maximum. SPECIFICATIONS ASME Section III N stamp ASME Section VIII Division 1 TEMA Classes B, C and R API ABS US Navy (Mil C-15730) The Pressure Equipment Directive (97/23/EC) Not all options are available on all Century series units; consult your ITT Standard representative or the factory. 10 11 www.ittstandard.com

For more information on this product please contact: Southgate Process Equipment Phone: (770) 345-42 Fax: (770) 594-0036 sales@southgateprocess.com www.southgateprocess.com Formally ITT Standard, American Standard, and Ross

S outhgate Process Equipment, Inc. HEAT TRANSFER AND ENERGY RECOVERY 87 Hickory Springs Industrial Drive Canton, Georgia 30115 Office (770) 345-0010 Fax (770) 345-4299 HEAT EXCHANGERS AND PRESSURE VESSELS STANDARD XCHANGE Commercial and engineered (TEMA) shell and tube heat exchangers. Plate and frame heat (formerly ITT STANDARD) exchangers with various material combinations, gasketed, welded and double wall designs. Brazed plate heat exchangers with standard and customized designs. MUNTERS/ DES CHAMPS Air to air economizers, tubular and plate style for high temperature applications. HEAT EXCHANGER Longitudinally finned hairpin and double pipe heat exchangers, large shell and tube heat exchangers, DESIGN, INC tank heaters and suction heaters. TEMA B, C, and R. INDUSTRIAL HEAT TRANSFER, INC ENERQUIP, LLC ELANCO J D COUSINS, INC. Finned tube heat transfer coils with continuous plate fin design. Many combinations of metals and custom designs. Shell and tube heat exchangers, all stainless steel sanitary designs for pharmaceutical and food applications. Spiral heat exchangers, welded plate and shell, ASME VIII. Large fabricated tanks and shell and tube heat exchangers for chemical, power and general industrial. FABSCO Air cooled forced draft finned tube heat exchangers. ASME VIII and API 661. CIRCLE-S PRODUCTS Dry-Flo moisture separators, coalescers, receivers and dry types in stock and custom sizes. Surge tanks, small tanks and ASME VIII pressure vessels. PACKAGED SYSTEMS & COMPONENTS SPIRAX SARCO, INC. ADVANTAGE ENGINEERING, INC KERR PUMP & SUPPLY ITT NEO-DYN & ITT CONOFLOW Steam control and condensate recovery systems, steam traps, control valves, regulators. Industrial chillers, air and water cooled in complete packaged systems. Standard and custom designs. Cooling Towers, Temperature Control Units, Pump/Reservoirs Systems. Custom designed skid mounted packaged systems with controls, filters, tanks, pumps, heat exchangers, etc. Regulators, transducers, actuators, positioners, temperature switches and pressure switches. GAUMER COMPANY Electric heaters, custom and stock. Immersion, circulation, duct, strip and band heaters. Packaged systems with optional controls. www.southgateprocess.com Phone: (770) 345-0010 Email: sales@southgateprocess.com