For more information on Pegler Yorkshire visit Heating Controls. Radiator valves with new integral push-fit inlet

Similar documents
Heating Controls Thermostatic and Manual Radiator Valve range

The new Terrier Belmont Thermostatic Radiator Valve range

FLEXIBLE METAL - BENDING THE RULES OF PLUMBING CONNECT WITH CONFIDENCE SEE OUR NEW EXTENDED RANGE OF VALVES -

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

COMPRESSION PLUMBING SOLUTIONS CONNECT WITH CONFIDENCE

Pegler Yorkshire reserve the right to change specifications. 10 Year Guarantee Luxury Taps and Mixers

Male elbow, copper x BSP taper male thread

Union coupling. copper x copper. Cone joint to BS 1010.

Komo Thermostatic Bar Shower. Excluding Shower Kit

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

Price list 1st March 2011

In-line thermostatic mixing valves

Thermostatic Bath Shower Mixer. Without shower kit.

Thermostatic mixing valves. Pegler Yorkshire

ANTI-SCALD THERMOSTATIC MIXING VALVES PUTTING YOU IN CONTROL

Basin Tap. Time delay maximum 2 seconds

Dual Control Thermostatic Bath and Shower Mixer

Code Description Dimensions 4P1061 RUNE CP MONOBLOC DUALFLOW SINK MIXER see image. Operating Pressure (bar)

Basin Mixer. Installation & Aftercare Instructions. Please retain for future reference.

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

BASIN MIXERS INSTALLATION & AFTERCARE INSTRUCTIONS

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

RA2000 Commercial TRVs

Enzo Concealed Shower Mixing Valve

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference

SOLUTIONS GUIDE. For total efficiency

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Thermostatic valves with radiator connection systems

Multilux 4-Eclipse-Set

Installation, Operating and Maintenance Guide

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

Infra Red Thermostatic Wall Mixer

CPC-180-ABNAB. 180 litres, 535mm x 1550mm high

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

M07. Wunda Premium Manifold. Before you start: Check the contents THE BRAND YOU CAN TRUST

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

Intatherm Safe Touch Basin Tap IT1008CP

CONCEALED THERMOSTATIC SHOWER MIXER VALVE installation & aftercare instruction

UB110DNC/L/U/B BASIN MONOBLOC WITH NO POP-UP WASTE BASIN MONOBLOC TALL WITH NO POP-UP WASTE UB112DNC/L/U/B INSTALLATION INSTRUCTIONS

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Flow Solutions Valves for Heating System Control

LOCKSHieLD. ReMOTe ADJUSTeR. MANUAL VALVeS. Belmont commercial radiator valves. Pegler Yorkshire

Mikrotherm. Manual Radiator Valves With presetting

Aquatique. Shower heads. Fixed and adjustable height heads. Aquatique shower kits installation guide page 1

Varsity Concealed Shower System

Installation Instructions & Operating Manual. Heat Exchanger PLEASE READ CAREFULLY BEFORE INSTALLING. Incorrect Installation Will Affect Your Warranty

NEW NEW. Qual-PEX Crimp System. Plumbing and Heating Installation Manual SAFE. Over 45 ye ars serving the Irish Plumbing Industry.

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill

P&HPG5 APRIL Plumbing & Heating Systems. EFFECTIVE: 25th APRIL Product Guide

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Thermostatic valve bodies

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Control valves for floor heating systems. Floor Heating Manifolds

HW3 Handwash Installation and Operating Instructions

Installation Instructions Flute Tap Range

INSTALLATION INSTRUCTION

METRO BASIN MONO MIXER CHR

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

thermostatic valve body with stepless precision presetting

Standard. thermostatic valve body without presetting

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Flipside Handshower and Showerhead Installation and User Guide

Bar valve with fixed and adjustable shower heads. Installation guide. Midas Plus installation instructions Page 1

Plus Bath Shower Mixing Valve CP and PL30020CP

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

Dream DCV. Thermostatic Dual control mixer valve range. Installation guide

Kiko Bath Shower Mixing Valve KK90015CP

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Puro Mini Dual Control Shower Mixer PU90010CP

Kinetic. Logic. Astin. THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions. Please retain for future reference

caleffi hydronic valves page 1 of 12

Inta City Concealed Shower Mixing Valve CT80010CP

PRECISION CONTROL FROM MYSON PLUS

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Installation, Operation & Maintenance Instructions

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

Atmos EasySolar. Installation Instructions for. Sloping roof and flat roof installation with evacuated tube collector

Installation, Operation & Maintenance Instructions

DEFENDER DEFENDER. Models: MD22A OPERATION MANUAL. Full Flow Magnetic Filter

Radiator Valve Program

Telo Shower Mixing Valve TL10016CP

Mixermate Instructions Shower [Product Numbers MS001, MS002, MS003, MS004, MS005, MS006, MS007.]

manifold, for radiators

Installation, Operating and Maintenance Guide

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

YORKEX, KUTERLON & MINIBORE COPPER TUBE

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Say heating. Say Herz. HERZ-Supply Engineering

Installation, Operation & Maintenance Instructions

Transcription:

Heating Controls Radiator valves with new integral push-fit inlet

Heating Controls Radiator valves with new integral push-fit inlet Terrier is a name which should need no introduction to the professional tradesman. For many years, Terrier radiator valves have enjoyed an unrivalled reputation for quality, reliability and their suitability for a wide range of heating applications. Now that reputation is to be further enhanced with the introduction of the new Terrier Push-fit range. The new Terrier Push-fit range has been developed using the wealth of knowledge of push-fit fittings and heating controls technology Pegler Yorkshire has built up over many years to deliver an integrated push-fit radiator product that truly offers the best of both worlds. Designed to meet the requirements of the new build sector, Terrier Push-fit successfully combines product quality and speed of installation, whilst being competitively priced. Speed of installation has been a key consideration and push-fit technology means many fitting complications are removed, greatly saving installation time on site and resulting in significant cost savings. The push element of jointing new Terrier Push-fit is instantaneous and the simple, tool-free jointing action requires no secondary operations in awkward areas, which means there is less chance of damaging chrome pipe as a result. Key features The Terrier Push-fit TRV showing the mm inlet Suitable for use with plain and chrome plated copper tube to BS EN 57 and PEX and PB plastic pipe to BS 7291 Parts 2 and 3 Integrated push-fit ends in mm and 15mm sizes Male ended push-fit elbows and straight connectors available separately Long life gland packing with rising spindle (manual valves only) Maximum water temperature 95 C

Pipe work preparation 1. Select the right size of tube or pipe to be connected to the valve. Ensure ends are clean and free from damage, scores and imperfections. Do not use any additional lubricant or sealing compounds. For copper tube, cut the tube square using a rotary tube cutter wherever possible, and for plastic pipe use pipe shears. Ensure the tube end is round and cut square. Installation instructions 2. Remove any burrs or sharp edges from the external tube end using a T1 Multipurpose tool from the Tectite accessories range. Also ensure the internal bore is deburred and the tube is wiped clean and free of debris. 3a. Where using Tectite- PEX barrier pipe that has been used on a previous installation, cut the tube back to behind the teeth 1. Drain down existing system, connecting a hosepipe to the lowest drain off point available. 2. Apply a suitable PTFE based compound or PTFE tape to the threaded end of the tail. Screw 1 / 2 BSP tail into radiator and tighten using a high quality open ended or adjustable spanner. 3. Connect the valve body to the tail, ensuring that the compression ring is seated centrally and that the tube makes firm contact with the tube stop in the valve body. Tighten nut, first using your fingers and then finish it by giving it a 3/ 4 to 1 turn with a high quality open ended or adjustable spanner. marks, ensuring there are no score marks on the pipe. Insert the correctly sized T66 pipe support liner from the Tectite accessories range fully into the pipe. 3b. If mm annealed copper tube (R2) is being used, ensure a T67 support liner is fully inserted into the tube. 4. Mark the tube/pipe with the correct socket depth using a marker/ pencil and the T1 Multipurpose tool or with a ruler to 23mm for both mm and 15mm valves. 5. When using chrome plated copper tube you must scribe the tube using the T1 tool. Fully insert tube into the T1 and rotate twice whilst firmly pressing the button; check that the tube has been scribed. 4. Remove manual shut off cap and store safely. With the sensor head set to the maximum setting (number 5) position the head so that the setting window can be viewed. Hand tighten the securing ring to fix the head in position. 5. Push the tube/pipe firmly with a slight twisting action until it reaches the tube stop with a positive click. 6. Ensure the depth insertion mark corresponds with the mouth of the inlet, then pull firmly on the tube/pipe to ensure the valve is secure.

PRESSURE DROP ( P) kpa Terrier TRV performance: Flow rate/pressure drop 0 80 60 50 40 30 8 6 5 4 3 2 2ºC OPEN FULL OPEN 1.01.02.02.02.05.06.08 0.1 2 3 4 5 6 8 Flow rates at a differential pressure of 0.1 bar 2K opening FLOW RATE (Q) LITRES/SECOND Full open Kv at 2K open l/s Kg/hr l/s Kg/hr m 3 /hr Maximum acceptable differential pressure valve will shut off p bar 0.053 0.053 0.053 0.053 0.053 0.6 Terrier tube compatibility Chrome plated copper tube Yes Copper tube Yes PEX pipe PB pipe Yes Yes Specification clauses The following specification clauses provide the exact wording required to ensure the correct Terrier product is used for the job. Terrier thermostatic radiator valves specification Thermostatic Radiator Valves (TRV) shall be bi-directional approved to EN 215, with double O ring seals. The TRV will be suitable for installing in the vertical orientation. They will have a push-fit inlet, suitable for jointing to plain or chrome plated copper tube to BS EN 57 or PB and PEX plastic pipe to BS 7291 Parts 2 and 3. Valve bodies manufactured from brass with polished chrome plate finish. Matching hand-wheel, lockshield and drain off lockshield options must be available. TRV s will be suitable for small bore or minibore central heating systems, including combination boilers, working with water pressures of up to bar (non-shock) and a maximum water temperature of 95 C. The thermostatic head will use a low hysteresis wax sensor, supporting a setting range of 7 C to 28 C, there shall be positive shut off when set in the 0 position and frost protection setting of 7 C. They will have a guarantee of 5 years against manufacturing defects and be drawn from the Terrier range from Pegler Yorkshire. Terrier manual radiator valves specification Manual radiator valves shall have a push-fit inlet, suitable for jointing to plain or chrome plated copper tube to BS EN 57 or PB and PEX plastic pipe to BS 7291 Parts 2 and 3. Valve bodies manufactured from brass to BS 2767, with polished chrome plate finish. Obtainable in hand-wheel, lockshield and drain off lockshield patterns, there will be matching thermostatic radiator valves (TRV) options available. They will be suitable for small bore or minibore central heating systems, including combination boilers, working with water pressures of up to bar (non-shock) and a maximum water temperature of 95 C. They will have a guarantee of 5 years against manufacturing defects and be drawn from the Terrier range from Pegler Yorkshire. Guarantee Terrier valves are guaranteed for 5 years against manufacturing defects. To qualify for these guarantees, products must be installed in accordance with our instructions on specified applications.

The new range comprises separate TRV, wheelhead and lockshield valves with integral push-fit mechanisms, or as packs which include a separate straight or elbow with push-fit integral connection. The straight fittings and elbows are also available separately in bow mm push-fit and 15mm sizes. The range can be used with plastic, copper and chrome pipe. ly in mm Flexibility A simple demountable tool has been designed for use with the product, which allows for maximum flexibility in both installation and alignment. This makes Terrier Push-fit the ideal solution should it prove necessary to re-align the pipe work at a later stage. Dimensions Thermostatic Radiator Valves Wheelhead Radiator Valves 1/ 2" x 15mm with mm elbow 60 133 35 50 27 1/ 2" x 15mm with 15mm elbow 60 133 35 53 33 1/ 2" x mm 60 133 35 - - 1/ 2" x 15mm 60 133 35 - - 1/ 2" x 15mm with mm elbow 60 84 34 50 27 1/ 2" x 15mm with 15mm elbow 60 84 34 53 33 1/ 2"xmm 60 84 34 - - 1/ 2"x15mm 60 84 34 - - Lockshield Radiator Valves Drainable Lockshield Radiator Valves 1/ 2" x 15mm with mm elbow 60 87 35 50 27 1/ 2" x 15mm with 15mm elbow 60 87 35 53 33 1/ 2"xmm 60 87 35 - - 1/ 2"x15mm 60 87 35 - - 1/ 2" x 15mm with mm elbow 77 87 35 50 27 1/ 2" x 15mm with 15mm elbow 77 87 35 53 33 1/ 2"xmm 77 87 35 - - 1/ 2"x15mm 77 87 35 - -

Heating Controls Terrier Manual Radiator Valves Integral Push-fit inlet 367PF CPWH Angle pattern wheelhead with elbow 15mm x 1 2" (mm elbow) 15mm x 1 2" (15mm elbow) 367PF CPWH Angle pattern wheelhead 6611 6612 mm x 1 2" 15mm x 1 2" 367PF CPWH Angle pattern wheelhead with elbow 6613 6614 15mm x 1 2" (mm elbow) 15mm x 1 2" (15mm elbow) 367PF CPLS Angle pattern lockshield 6615 6616 mm x 1 2" 15mm x 1 2" 367PF CPDLS Angle pattern drainable lockshield with elbow 6617 6618 15mm x 1 2" (mm elbow) 6619 Terrier Thermostatic Radiator Valves Integral Push-fit inlet TRV PF Thermostatic radiator valve with elbow 15mm x 1 2" (mm elbow) 15mm x 1 2" (15mm elbow) TRV PF Thermostatic radiator valve Terrier Radiator Valve Packs Integral Push-fit inlet 6621 6622 mm x 1 2" 15mm x 1 2" TRV PF & 367PF CPLS Lockshield pack 6623 6624 15mm x 1 2" (mm elbow) 6625 TRV PF & 367PF CPLS Lockshield pack with elbows 15mm x 1 2" (mm elbow) 6626 TRV PF & 367PF CPDLS Drainable lockshield pack with elbows 15mm x 1 2" (mm elbow) 6627 Terrier Integral Push-fit Connectors Elbow connector Use with Compression or Integral Push-fit valve inlet 15 x mm 15mm Straight connector Use with Compression or Integral Push-fit valve inlet SIZE A B C 15 x mm 22.5 23 23 15mm 27.5 30 23 Terrier Accessories 7P 7P12 15 x mm 15mm Release tool Use with Integral Push-fit valve inlet 7P11 7P13 mm 15mm T1 Multipurpose tool Deburring/Depth gauge/scribe, Use with Integral Push-fit valve inlet 5 5 7P14 7P15 N/A 1 7P16 The perfect commercial partnership Our world leading brands For further information, please contact your appropriate sales office Pegler is an expert in the production of Taps, Mixers and Valve products. It boasts an unrivalled track record for integrity, quality, reliability and innovation. Yorkshire is a specialist in the production of metal plumbing and heating fittings. It has an established reputation for manufacturing quality products. www.pegleryorkshire.co.uk UK Northern team Tel: 0870 10281 Fax: 01302 5608 UK Southern team Tel: 0870 10282 Fax: 01302 560458 UK Western team Tel: 0870 10283 Fax: 01302 5609 UK Eastern team Tel: 0870 10282 Fax: 01302 560458 Export Tel: +44 (0) 1302 855656 Fax: +44 (0) 1302 730513 uk.sales@pegler.co.uk export@pegler.co.uk Pegler Limited, St. Catherine's Avenue, Doncaster, South Yorkshire, DN4 8DF. Registered Company No. 01194543. Place of Registration: England. All brand names and logo styles are registered trademarks. LIT.REF: 880112.0408 Maintaining a policy of continual product development, Pegler Yorkshire reserve the right to change specifications, design and materials of products listed in this databook without prior notice.