SUPERIOR QUALITY HEAT INTERFACE UNITS PUTTING YOU IN CONTROL. Pegler Yorkshire

Similar documents
ANTI-SCALD THERMOSTATIC MIXING VALVES PUTTING YOU IN CONTROL

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

heat interface units A BOILER WITHOUT A FLAME

COMPRESSION PLUMBING SOLUTIONS CONNECT WITH CONFIDENCE

In-line thermostatic mixing valves

Stored Water District Heating Interface Units. Heat Interface Units

THERMAL INTERFACE UNITS. Designed and manufactured in the UK. Designed for performance

Thermostatic mixing valves. Pegler Yorkshire

Herz York Direct Heat Interface Unit

Meibes Heat Interface Unit (HIU) A2RXE Instantaneous Hot Water & Space Heating

FLEXIBLE METAL - BENDING THE RULES OF PLUMBING CONNECT WITH CONFIDENCE SEE OUR NEW EXTENDED RANGE OF VALVES -

T. +44 (0) E.

ModuSat TP. Energy. Heat Interface Units

ModuSat TP. Energy. Heat Interface Units

Contact person Date Reference Page Daniel Månsson P07886C-rev2 1 (14) Energy and bioeconomy

System Design for efficiency using electronic, intelligent HIU s. Neil Parry CIBSE Accredited Heat Network Consultant

Design & Product Guide. Danfoss FlatStations.

SOLAR HEATING SYSTEMS

Where gas is not an option,

T. +44 (0) E.

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

GIACOMINI HEAT INTERFACE UNITS

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

EcoSeries S O L A R H O T WAT E R S O L U T I O N S. Ecological & Economical

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

Contact person RISE Date Reference Page Daniel Månsson P (13) Energy and circular economy

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

Heat Interface Units for decentralised water heating in district heating systems

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

IDEAL LOGIC HEAT INTERFACE UNITS (HIUs) PRODUCT GUIDE.

INTERCYL. INTERNAL EXPANSION EXCELLENCE

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

Sirius FS. Working towards a cleaner future

InTec 2 X HIGH EFFICIENCY BOILERS LOW CARBON SOLUTIONS

New Zealand Sales Hotline: Sales Fax:

Pressure Boosting Solutions

AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously)

EFG ENERGY OPTIMISING SYSTEMS

The Ultimate Solution for Electric Central Heating. Fusion. Comet

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

Maincor Underfloor Heating UNDERFLOOR HEATING SYSTEMS. Introduction. Overview. Tel: Web: Why use Underfloor Heating?

VENTED CYLINDER RANGE

Vented systems explained Performance without compromise Vented System (Gravity Fed) Positive Head Systems

SATK 30 heat interface unit

ADVANCE ECB ELECTRIC COMBINATION BOILER

QUALITY DESIGN. BUILT-IN RELIABILITY. CYLINDERS. The complete range of Warmflow Cylinders.

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

Stainless Steel Unvented Cylinders

maximise the sun s energy with warmflow solar Warmflow Solar

TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

CT range. of shower, bathroom and whole house pumps

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS

Baxi Combi HE Range. Baxi Combi HE. Keeping Britain Warm

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Performance on demand. Eliminate poor mains water pressure and flow problems. with mainsboost

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Solar thermal domestic hot water system

STAINLESSLITE ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

thermocompact High performance system boiler range

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

For more information on Pegler Yorkshire visit Heating Controls. Radiator valves with new integral push-fit inlet

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

Super high efficiency heating and hot water boilers for every type of home and commercial property.

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

the electric heating company ELECTRIC BOILER HANDBOOK

Unvented water heating

Thermostatic Bath Shower Mixer. Without shower kit.

Gas Condensing Boilers

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

ecotec plus New high efficiency condensing combination and system boiler ranges

Amptec. Electric flow boiler

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

Thermostatic bar mixer valve with adjustable head Installation guide

35% Ultra-efficient brazed heat exchangers for your district energy applications. Up to. Brazed Micro Plate heat exchangers

Solar heating systems

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

Link-Up. Solid Fuel Association Guide to Central Heating.

UNDERFLOOR HEATING SYSTEM C SYH ME UNDERFLOOR HEATING SYSTEM. Heating Homes All Around The World.

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Grant Energy Management Control Systems. Includes weather compensation, sequence controllers, low loss headers and zone pumps

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

installation INSTRUCTIONS

The iqe Boiler Range. Combination and System T Boilers.

SMART HOT WATER SOLUTIONS PRODUCT RANGE

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Combined electric boiler and domestic hot water store

SEALED THERMAL STORE

EnergyMasterHP. user guide. Cylinder for use with NIBE heat pump systems. v12 Nu-Heat 2017 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill

POINT OF USE WATER HEATERS

Commercial Hot Water Solutions Ltd.

Transcription:

SUPERIOR QUALITY HEAT INTERFACE UNITS PUTTING YOU IN CONTROL Pegler Yorkshire

Pegler Yorkshire PUTTING YOU IN CONTROL Diverse industry expertise combined with cuttingedge technological innovation mean Pegler Yorkshire s Control solutions help you overcome unique challenges and meet the highest standards in both performance and system aesthetics. PERFORMANCE WITH PRECISION Pegler Yorkshire s Control products enable you to balance precision flow control, energy efficiency and comfort through innovative products and systems that ensure building performance criteria are met and the resulting installation is easy, efficient and economical to operate. Our comprehensive Terrier, Meibes and Ballorex product ranges offer proven energy saving solutions, exceptional accuracy and optimised system performance so, whatever your project or challenge, you can be sure you ll always be in control. GLOBAL EXPERIENCE, COMBINED EXPERTISE With over 100 years of manufacturing and innovation combined with extensive industry knowledge and worldwide market experience, Pegler Yorkshire offers the most advanced and complete Connect & Control systems on a global scale. As one of Britain s largest and most respected manufacturers and suppliers of products for the plumbing and heating industries, Pegler Yorkshire is confident we can provide you with all the controls, connections and support your project requires. For more information visit www.pegleryorkshire.co.uk 2

CONTENTS Pegler Yorkshire is pleased to be associated with several influential industry organisations: ENERGY EFFICIENT SOLUTIONS SUITABLE FOR CENTRALISED BOILER PLANTS Introduction 4 A comprehensive range for all applications 4-5 Service 6 Energy efficiency with improved SAP ratings 7 A TOTAL SUPPORT PACKAGE FOR SPECIFIERS, CONTRACTORS AND FACILITIES MANAGERS Benefits 8 Choosing the best system for your application 9-11 Association of Plumbing and Heating Contractors The UK Copper Board The Bathroom Manufacturers Association The Chartered Institution of Building Services Engineers PRODUCT DETAILS Product focus 12-13 A2 RX Blu-Climate range 14-17 A2 UX Blu-Climate range 18-21 A1 RX Blu-Climate range 22-25 A1 CX Blu-Climate range 26-29 Brass The Brass Page for specifiers, designers, engineers and manufacturers pec CERTIFICATION LTD British Plumbing Employers Council TECHNICAL GLOSSARY 30-31 DISTRICT HEATING SYSTEMS CLIMATE CONTROL 32-33 Thermostatic Mixing Valve Manufacturers Association Construction Products Association The Copper Development Association Scottish and Northern Ireland Plumbing Employers Federation Builders Merchants Federation Institute of Plumbing The UK District Energy Association 3

ENERGY EFFICIENT SOLUTIONS SUITABLE FOR CENTRALISED BOILER PLANTS The Meibes brand and German heritage is renowned for its precision engineering quality and innovative designs that deliver unparalleled performance, efficiency and ease of installation. Meibes Heat Interface Units (HIUs) facilitate the use of centralised systems for space heating and domestic hot water in multi-residential buildings. They are high performing units, engineered with fully tested and approved components, designed to provide optimum performance for end users, while ensuring that they are easy to install and maintain. Pegler Yorkshire also holds a comprehensive range of spares for fast delivery throughout the UK. Meibes HIUs are pre-fabricated units linked to the central heat source(s) via a network of three pipes heating flow and return and a separate potable water feed. A zone valve in each unit, linked to a standard timer and room thermostats, controls the space heating for each apartment. A patented Proportional Modulating (PM) valve intelligently prioritises the requirement for domestic hot water (DHW) over heating, in a similar way to a combi boiler. The Meibes HIUs offered by Pegler Yorkshire have been designed to meet the specific needs of the UK market. For example, Meibes HIUs for the UK are configured for top-entry pipework for ease of installation in ceiling voids A COMPREHENSIVE RANGE FOR ALL APPLICATIONS The breadth of the Meibes HIU range delivers solutions for all types of centralised heating networks serving multi-residential accommodation, ensuring effective control of heating and DHW in apartments and other spaces. The design of HIUs facilitates a balanced system that delivers consistent performance, irrespective of variation in hot water demands or how far the units are from the plant room. TYPICAL APPLICATIONS Private apartments Local Authority accommodation Housing Associations Student accommodation Nurse accommodation Sheltered housing. 4

Whatever the application, Meibes HIU have the authoritative solution DESIGN Performance Pegler Yorkshire has various high performance Meibes HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use and against the overall building requirements. Guidance on network and temperature flow rates can also be provided by the Pegler Yorkshire team. Allocating design space Meibes HIU headline A2 RX Indirect Heating and Domestic Hot Water units are compact in size at only 500mm wide, enabling them to be fitted into minimal cupboard space. This also provides the option to fit them into an appliance space. Further options are also available for direct heating units at 650mm wide. UK solution Pegler Yorkshire ensures that UK experience, system design and installation and practices drive the solution to the product, which is why the Meibes range of HIUs is designed to meet UK needs. As a result there is no need to compromise and adapt to HIU s with a European configuration. BUILD Installation innovation The Meibes HIU range is part of Pegler Yorkshire Connect & Control, which fully recognises the importance of minimising installation costs whilst ensuring the building performs efficiently and optimally. Meibes HIUs were one of the first to be designed with a first fix rail which is available to aid staged installation, supporting the primary network set-up. No special commissioning required Meibes HIUs are designed to remove complications and provide clarity on installation. There is no need to have a specialist for commissioning as the standard installation process requires a competent installer to simply follow the specifier s set-up parameters. Expertise Pegler Yorkshire is one the leading manufacturers of commercial plumbing and heating systems. Our expertise and experience enables contractors to benefit significantly when it comes to project costs, and technical and service support, by using a connect and control system they can trust. 5

ENERGY EFFICIENT SOLUTIONS SUITABLE FOR CENTRALISED BOILER PLANTS SERVICE Guarantee Pegler Yorkshire provides ultimate engineering and performance confidence. Down time can lead to client frustration and experience is the key to a well-managed building project. Meibes HIUs combine high quality components and reliability to deliver a peace of mind proposition which prevents expensive call backs. Service Pegler Yorkshire is committed to providing an after service experience that allows peace of mind for contractors and facility managers. A network of service teams is available with dedicated telephone support lines providing technical advice. 2year guarantee on moving parts 6

ENERGY EFFICIENCY WITH IMPROVED SAP RATINGS Centralised heating systems are becoming increasingly popular for multi-residential properties as they offer a number of key advantages over decentralised systems with individual boilers in each apartment. These include: Improved energy efficiency 11% improvement in SAP ratings (compared to decentralised systems) No gas installation throughout the building No flues in apartments Ease of access to heating plant for maintenance Simple integration of low carbon and renewable heat sources. Energy-saving features of Meibes HIUs Meibes HIUs operate on a no demand-no flow basis, so that when there is no demand for heating or DHW the unit effectively goes into standby. The arrangement minimises the demand on the main network, reduces energy consumption and ensures the apartment is not over-heated. The performance of the units is based on primary flow temperatures of 65 C, enabling use with low carbon heat sources such as heat pumps. The resulting low return water temperatures also help to maximise condensing when condensing boilers are used. To help ensure minimum heat losses from the system, all pipework is pre-insulated to save energy and reduce onsite insulation work. For further energy savings an A-rated pump aligns water flows with heating demand to minimise pump energy consumption. 7

A TOTAL SUPPORT PACKAGE FOR SPECIFIERS, CONTRACTORS AND FACILITIES MANAGERS Meibes HIUs deliver key benefits for all parties in the supply chain, from initial system design through to everyday operation and maintenance. All backed by the expertise and support of Pegler Yorkshire. BENEFITS FOR SPECIFIERS AND DEVELOPERS Lower capital costs Reduced installation time Simpler design of heating systems Simpler pipework systems No hot water storage necessary Improved energy efficiency and SAP rating Facilitates integration of different heat sources All distribution at low pressure and temperature Easier to gain planning consent. BENEFITS FOR CONTRACTORS Ease of installation Faster fix times Ability to separate first and second fix Ease of access to components Annual servicing requirement. BENEFITS FOR FACILITIES/PROPERTY MANAGERS All plant in a single plant room No need to enter apartments for routine maintenance Reduced energy consumption Heat metering for billing residents Ease of renewables inclusion Reduced carbon footprint Reduced annual boiler servicing cost over individual boilers. 8

CHOOSING THE BEST SYSTEM FOR YOUR APPLICATION The Meibes HIU range includes a number of different models for different applications. Use the flow chart below to select the most appropriate model for your project. No. of bathrooms Heating & DHW Heating to be connected to the supply (direct) or Separated via a heat exchanger (indirect)? Direct Heating & DHW DHW requirement for shower/ bath? One Two Meibes HIU A1 RX + Accessories Indirect Heating & DHW DHW requirement for shower/ bath? No. of bathrooms One Two Meibes HIU A2 RX Meibes HIU A2 RX Radiator + Accessories Stored DHW requirement? Instantaneous DHW requirement? Heat Exchanger Type of Emitter? Underfloor DHW requirement for shower/ bath? No. of bathrooms One Two Meibes HIU A2 UX Meibes HIU A2 UX + Accessories No. of bathrooms Cylinder DHW requirement for shower/ bath? One Two Meibes HIU A1 CX + Accessories 9

CHOOSING THE BEST SYSTEM FOR YOUR APPLICATION The comprehensive Meibes HIU range ensures that these units can be used with a range of different system configurations. INDIRECT SYSTEM A2 RX/A2 UX The indirect system provides both indirect space heating and indirect DHW. The system uses twin heat exchange units to supply instantaneous DHW and space heating. The Proportional Modulating Valve operates in the same way as a combi diverter valves. Whenever there is a call for DHW, the PM valve diverts the primary flow through the heat exchanger to generate DHW, using all available energy to support the DHW demand. Typically, this results in the heating circuit being closed for just a few minutes, having minimal impact on occupant comfort. When the DHW demand has been satisfied the primary flow reverts to the space heating system. CENTRAL HEAT GENERATOR Mains water Primary flow Primary return HEAT INTERFACE UNIT (Primary heating separate to apartment circuit) Heating flow Heating return Potable water DHW flow RADIATOR/ UNDERFLOOR HEATING SYSTEM BENEFITS Reduces heat losses Reduces pumped volume around primary circuit Removes peak load issues Protects against variation in flow and return rates between apartments Separate heating circuit Flexible temperature control Low maintenance requirements. DIRECT SYSTEM A1 RX The direct configuration delivers the primary heating direct to the apartment circuit, with indirect DHW. CENTRAL HEAT GENERATOR HEAT INTERFACE UNIT SYSTEM BENEFITS Reduced cost Less space required in apartment Low maintenance requirements. (Primary heating direct to apartment circuit) Mains water Primary flow Primary return Heating flow Heating return Potable water DHW flow HEAT EMITTER INDIRECT FOR CYLINDER SYSTEM A1 CX When using a cylinder system the primary circuit is separate to the secondary circuit, so that hot water is supplied from the cylinder, ensuring hot water is always available. The system incorporates a zone valve which is controlled by standard controls such as a time clock and a room thermostat to switch off the unit when there is no demand, thereby reducing network load. CENTRAL HEAT GENERATOR HEAT INTERFACE UNIT (Using a cylinder system) DHW CYLINDER SYSTEM BENEFITS Simple design Differential pressure control Heat usage metered Hot water reserve in apartment. Mains water Primary flow Primary return Heating flow Heating return Potable water DHW flow HEAT EMITTER 10

A2 RX A1 RX A1 CX A2 UX 11

PRODUCT FOCUS Primary return Primary flow Cold water mains DHW Heating flow Heating return Strainer protects from system debris and prolongs life Strainer protects from system debris and prolongs life Differential Pressure Control Valve improved control, performance and installation Blending valve Pump A-rated pump ensures efficient performance Proportional Modulation Valve gives priority to heating over DHW Heat exchanger (DHW) provides highly efficient performance from a compact unit Heat exchanger (IH) A2 RX HIU 12

FIX RAILS First fix rails allow a faster installation that can be staged to align with progress on other parts of the project. For example, the first fix may be carried out in the early stages, with the HIUs themselves being installed later in the project schedule. This reduces the risk of onsite damage to the HIUs. The first fix rail is secured to the wall in the appropriate position allowing all plumbing connections to be made, pressure tested, flushed and filled. Depending on the nature of the contract, this may also support staged billing for work carried out and products installed. Primary Bypass Module First fix Rail (also available with Primary Bypass Module) FEATURES WRAS approved ball valves Factory sealed flow/ return connections Available with bypass for easy system flushing Fix rail supports primary pipe work testing. HEAT METERS Meibes HIUs can be factory-fitted with optional heat meters, allowing for accurate, measurement of heat energy use in individual apartments. Use of factory-fitted heat meters reduces onsite work and enables optimum use of skilled labour for more complex tasks. Factory-fitted units are pressure tested before delivery to site. Data from the heat meters can be collected manually or via a wired or wireless network. Pre-payment can also be incorporated. FEATURES Heat meter measures the differential between flow and return temperatures MID approved factory fitted ultrasonic heat meters Conforms to EN1434-3;1997 RHI and OMS compliant Common Mbus output into data extraction 10 year battery life Permanent display (shown in kwh). DATA EXTRACTION The most popular form of data extraction from heat meters is an Mbus network connection, which can be pre-fitted to the heat meter. The data extraction unit sends a master signal to slave meters, which then report on energy consumption data. The readings can be sent via email or pulled directly from the data logger. Where required, heat meters can be fitted with radio-based data extraction systems. Available May 2014 FEATURES Ability to consolidate readings from up to 400 meters Allows data extraction to be directly or remotely configured Flexible programming allows meter readings to be time defined Data can be retrieved or sent automatically via email as CSV-file or xml-file SD card as back-up to prevent risk of data loss. 13

PRODUCT DETAILS MEIBES HIU INDIRECT UNIT A2 RX BLU-CLIMATE RANGE 14

MEIBES HIU A2 RX BLU-CLIMATE RANGE The A2 RX is a higher capacity version of the A1 RX, suitable for apartments with two bathrooms. FEATURES & BENEFITS Designed to provide instantaneous Domestic Hot Water and Indirect Heating Compact design 500mm wide Available in 15 and 19 litres per minute of DHW HIU enables secondary heating for radiators High specification Differential Pressure Control Valve Unique trickle bypass to enable unit primed for DHW Available with case with window for viewing heat meter Also available without case for fitting within an existing cabinet First fix rails and bypass option also available Complete with WRAS approved ball valves Top connections for easy contractor access. 687902/687906 A2 RX Blu-Climate HIU range options HIU model With box With heat meter Code Meibes A2 RX Blu-Climate HIU 15 IDH & HW HM Yes Yes 687900 Meibes A2 RX Blu-Climate HIU 15 IDH & HW Yes No 687901 Meibes A2 RX Blu-Climate HIU 15 IDH & HW HM B No Yes 687902 Meibes A2 RX Blu-Climate HIU 15 IDH & HW B No No 687903 Meibes A2 RX Blu-Climate HIU 19 IDH & HW HM Yes Yes 687904 Meibes A2 RX Blu-Climate HIU 19 IDH & HW Yes No 687905 Meibes A2 RX Blu-Climate HIU 19 IDH & HW HM B No Yes 687906 Meibes A2 RX Blu-Climate HIU 19 IDH & HW B No No 687907 A2 RX Blu-Climate HIU accessory options Accessory Code Meibes A2 RX Fix Rail 687550 Meibes A2 RX Fix Rail TP 687551 15

PRODUCT DETAILS MEIBES HIU TECHNICAL & PERFORMANCE DATA A2 RX BLU-CLIMATE RANGE A2 RX Blu-Climate HIU Technical data Description Construction Duty (primary) domestic hot water mode Duty (secondary) domestic hot water Duty (secondary) heating Type Mounting Size (WxDxH, height of the case) Heating system Pipework Plates heat exchanger Casing Primary fluid Secondary fluid heating Secondary fluid domestic hot water Heat Interface Unit for indirect heating and instantaneous domestic hot water Wall mounted 500 x 350 x 750mm 2 pipe flow Fully insulated flexible stainless steel with brass fittings Stainless steel (heat exchanger space heating fully insulated) White powder coated sheet steel cover Low pressure hot water Low pressure hot water Potable hot water service Heat transfer capacity 42kW 50kW Flow rate 0.275 l/s (990 l/h) 0.282 l/s (1,014 l/h) Minimum flow temperature primary 65ºC 65ºC Heat transfer capacity 42kW @ 40K ΔT 50kW @ 40K ΔT Flow rate 15 l/min (0.250 l/s) 19 l/min (0.317 l/s) Fluid temperature in 10ºC 10ºC Fluid temperature out 50ºC 50ºC Blending valve 35-65ºC 35-65ºC Capacity 20kW max. @ 20K ΔT 20kW max. @ 20K ΔT Fluid temperature flow 60ºC @ 65ºC primary flow 60ºC @ 65ºC primary flow Fluid temperature return 40ºC 40ºC Maximum primary pressure 10bar 10bar Pressure Maximum secondary pressure 3bar 3bar Minimum supply water pressure 2bar, maximum 4bar 2bar, maximum 4bar Connections All external connections ¾" ¾" Fittings primary and secondary heating Fittings secondary domestic hot water service Secondary circulation pump Expansion vessel Strainer Sensor pockets Heat meter Differential Pressure Control Valve (DPCV) Primary bypass/trickle bypass Air vents Controls Controls Wilo A rated pump in secondary flow 8 litre fitted in secondary flow On primary flow and secondary return Flow for heat meter Rossweiner HeatSonic M-Bus heat meter with permanent display Factory set at 30kPa (maximum differential pressure 250kPa) Thermostatic bypass between primary flow and return Manual Not pre-fitted externally mounted single channel time switch + roomstat Proportional modulation controlled 16

Dimensions and clearances Hydraulic layout Primary side Secondary side Return Flow Cold water mains Domestic hot/cold water DHW Flow Return 1 3 W 4 2 8 2 5 3 16 6 7 10 15 9 M 12 13 14 P 11 750mm 500mm 350mm Key 1 First fix Rail with connection ball valves (not illustrated) 2 Strainer 3 Provision for test points (½" connection) 4 Heat meter 5 Differential Pressure Control Valve (DPCV) 6 Proportional Modulation Valve (PMV) 7 Plate heat exchanger, DHW 8 Thermostatic blending valve 9 Drain point 10 Thermostatic circulation valve (trickle bypass) 11 Zone valve. Primary side space heating circuit 12 Plate heat exchanger. Space heating 13 Pressure gauge, secondary side 14 Over pressure relief valve, secondary side 15 Expansion vessel 16 Circulator pump, secondary side Flow performance 100 100 90 90 80 80 70 15L of DHW @ 60ºC 70 19L of DHW @ 60ºC Primary flow degrees ºC 60 50 40 15L of DHW @ 50ºC 15L of DHW @ 45ºC Primary flow degrees ºC 60 50 40 19L of DHW @ 50ºC 19L of DHW @ 45ºC 30 30 20 36.43kW/cold water 10ºC 41.61kW/cold water 10ºC 20 46.15kW/cold water 10ºC 52.70kW/cold water 10ºC 10 51.92kW/cold water 10ºC *The primary flow should not exceed 1,000 l/h 10 64.76kW/cold water 10ºC *The primary flow should not exceed 1,000 l/h 0 0 0 500 1000 1500 2000 2500 3000 3500 Primary flow rate l/h* 0 500 1000 1500 2000 2500 3000 3500 Primary flow rate l/h* 17

PRODUCT DETAILS MEIBES HIU INDIRECT UNIT A2 UX BLU-CLIMATE RANGE 18

MEIBES HIU A2 UX BLU-CLIMATE RANGE A2 UX models have been specifically designed for use with underfloor heating. FEATURES & BENEFITS Designed to provide instantaneous Domestic Hot Water and Indirect Heating Compact design 500mm wide Available in 19 litres per minute of DHW HIU enables secondary heating for underfloor heating Integrated thermix module High specification Differential Pressure Control Valve Unique trickle bypass to enable unit primed for DHW Available with case with window for viewing heat meter Also available without case for fitting within an existing cabinet Complete with fix rails Bypass option also available Complete with WRAS approved ball valves Top connections for easy contractor access. Available May 2014 687932 A2 UX Blu-Climate HIU range options HIU model With box With heat meter Code Meibes A2 UX Blu-Climate HIU 19 IDH & HW HM Yes Yes 687930 Meibes A2 UX Blu-Climate HIU 19 IDH & HW Yes No 687931 Meibes A2 UX Blu-Climate HIU 19 IDH & HW HM B No Yes 687932 Meibes A2 UX Blu-Climate HIU 19 IDH & HW B No No 687933 A2 UX Blu-Climate HIU accessory options Accessory Code Meibes A2 RX Fix Rail 687550 Meibes A2 RX Fix Rail TP 687551 19

PRODUCT DETAILS MEIBES HIU TECHNICAL & PERFORMANCE DATA A2 UX BLU-CLIMATE RANGE A2 UX Blu-Climate HIU Technical data Description Construction Duty (primary) domestic hot water mode Duty (secondary) domestic hot water Duty (secondary) heating Type Mounting Size (WxDxH, height of the case) Heating system Pipework Plates heat exchanger Casing Primary fluid Secondary fluid heating Secondary fluid domestic hot water District heating station for indirect heating and instantaneous domestic hot water Wall mounted 500 x 350 x 750mm 2 pipe flow Fully insulated flexible stainless steel with brass fittings Stainless steel (heat exchanger space heating fully insulated) White powder coated sheet steel cover Low pressure hot water Low pressure hot water Potable hot water service Heat transfer capacity 50kW Flow rate 0.282 l/s (1,014 l/h) Minimum flow temperature primary 65ºC Heat transfer capacity 50kW @ 40K ΔT Flow rate 19 l/min (0.317 l/s) Fluid temperature in 10ºC Fluid temperature out 50ºC @ 65ºC primary flow temperature Blending valve 35-65ºC Capacity Fluid temperature flow Fluid temperature return 20kW max. @ 20K ΔT 60ºC @ 65ºC primary flow Max. 40ºC (depends on UFH settings) Maximum primary pressure 10bar Pressure Maximum secondary pressure 3bar Minimum supply water pressure 2bar Maximum supply water pressure 4bar Connections All external connections ¾" Fittings primary and secondary heating Fittings secondary domestic hot water service Secondary circulation pump Expansion vessel Strainer Sensor pockets Test points Heat meter Differential Pressure Control Valve (DPCV) Primary bypass/trickle bypass Air vents Zone valve Controls Controls Thermix underfloor heating module with Grundfos pump and automatic mixer 20-80ºC 12 litre fitted in secondary flow On primary flow and secondary return Flow for heat meter Binder style test points Rossweiner HeatSonic M-Bus heat meter with permanent display Factory set at 30kPa (maximum differential pressure 250kPa) Thermostatic bypass between primary flow and return Manual Fitted with electrical actuator head, max. differential pressure 100 kpa (kvs=1.85) Not pre-fitted externally mounted single channel time switch + roomstat Proportional modulation controlled 20

Dimensions and clearances Hydraulic layout Primary side Return Flow Domestic hot/cold water Secondary side Cold water DHW mains Flow Return 1 3 W 4 2 8 2 5 3 16 6 7 10 15 9 M 12 13 14 P 11 750mm 500mm 350mm Key 1 First fix rail with isolating ball valves 2 Strainer 3 Provision for test points (½" connection) 4 Heat meter 5 Differential Pressure Control Valve (DPCV) 6 Proportional Modulation Valve (PMV) 7 Plate heat exchanger, DHW 8 Thermostatic blending valve 9 Drain point 10 Thermostatic circulation valve (trickle bypass) 11 Zone valve. Primary side space heating circuit 12 Plate heat exchanger. Space heating 13 Pressure gauge, secondary side 14 Over pressure relief valve, secondary side 15 Expansion vessel 16 Underfloor heating, module secondary side (inc. pump mixer) Flow performance 100 100 90 90 80 80 70 15L of DHW @ 60ºC 70 19L of DHW @ 60ºC Primary flow degrees ºC 60 50 40 15L of DHW @ 50ºC 15L of DHW @ 45ºC Primary flow degrees ºC 60 50 40 19L of DHW @ 50ºC 19L of DHW @ 45ºC 30 30 20 36.43kW/cold water 10ºC 41.61kW/cold water 10ºC 20 46.15kW/cold water 10ºC 52.70kW/cold water 10ºC 10 51.92kW/cold water 10ºC *The primary flow should not exceed 1,000 l/h 10 64.76kW/cold water 10ºC *The primary flow should not exceed 1,000 l/h 0 0 0 500 1000 1500 2000 2500 3000 3500 Primary flow rate l/h* 0 500 1000 1500 2000 2500 3000 3500 Primary flow rate l/h* 21

PRODUCT DETAILS MEIBES HIU DIRECT UNIT A1 RX BLU-CLIMATE RANGE 22

MEIBES HIU A1 RX BLU-CLIMATE RANGE The A1 RX unit provides direct heating and instantaneous hot water. FEATURES & BENEFITS Designed to provide instantaneous Domestic Hot Water and Direct Heating Compact design 600mm wide Available in 17 litres per minute of DHW HIU enables differential pressure controlled primary heating for radiators Unique trickle bypass to enable unit primed for DHW Includes heat meter (optional) Also available without case for fitting within an existing cabinet Complete with fix rails and connectors for top connection Complete with WRAS approved ball valves. Top connection Bottom connection A1 RX Blu-Climate HIU range options HIU model With box With heat meter Code Meibes A1 RX Blu-Climate HIU 17 DH & HW HM Yes Yes 687950 Meibes A1 RX Blu-Climate HIU 17 DH & HW Yes No 687951 Meibes A1 RX Blu-Climate HIU 17 DH & HW HM B No Yes 687952 Meibes A1 RX Blu-Climate HIU 17 DH & HW B No No 687953 A1 RX Blu-Climate HIU accessory options Accessory Code Meibes A1 RX Fix Rail (for bottom connection) 687570 Meibes A1 RX Fix Rail (for top connection) 687573 Meibes A1 RX Hose Flush 687571 Meibes A1 RX Water Meter 687572 23

PRODUCT DETAILS MEIBES HIU TECHNICAL & PERFORMANCE DATA A1 RX BLU-CLIMATE RANGE A1 RX Blu-Climate HIU Technical data Description Type Mounting Size (WxDxH, height of the case) Heating system Pipework Apartment substation for direct and instantaneous domestic hot water Wall mounted 600 x 210 x 800mm 2 pipe flow Fully insulated flexible stainless steel with brass fittings Construction Duty (primary) domestic hot water mode Plate heat exchanger Casing Heating fluid Domestic hot water Stainless steel heat exchanger for domestic hot water (non-insulated for fast cool down/insulated if optional sanitary circulation) White powder coated sheet steel cover Low pressure hot water Potable hot water service Heat transfer capacity 46kW Primary flow rate 910 l/h Minimum flow temperature primary 65ºC Flow rate 17 l/min Flow limiter Internal choke disk at cold water inlet Duty (sanitary) Fluid temperature in 10ºC Fluid temperature out 50ºC @ 65ºC primary flow temperature Blending valve 35-65ºC Duty (space heating) Capacity 10kW max. @ 20K ΔT Maximum primary pressure 6bar Pressure Maximum supply water pressure 10bar Optimal supply water pressure 2bar Temperatures Maximum operating temperature 110ºC Connections All external connections ¾" Fittings heating Fittings domestic hot water service Strainer (optional) Sensor pockets Heat meter mounting Heat meter (optional) Differential Pressure Control Valve (optional) Primary bypass/trickle bypass Air vents Zone valve Heating control (optional) Control Water meter mounting (optional) Water meter (optional) Connection (optional) Sanitary circulation (optional) In primary flow inlet and/or space heating return (not LogoComfort Basis 600 plus) Sensor pocket in primary flow for optional heat meter 110mm spool piece in primary return flow Rossweiner HeatSonic M-Bus heat meter with permanent display Mounted in primary flow. Factory set = 30kPa, maximum differential pressure = 250kPa Thermostatic bypass between primary flow and return (adjustable 45-65ºC) Manual In space heating return flow for optional electric actuator head mounting kvs = 1.85 Externally mounted electronic room heating control Proportional flow control with priority switch 110mm spool piece in cold water inlet Rossweiner water meter, M-Bus Second cold water outlet after water meter Sanitary circulation pump Wilo Star-Z Nova (P max = 4.5W) and external time switch 24

Dimensions and clearances Hydraulic layout 4 1 2 13 3 M 5 9 4 6 10 7 12 8 10 800mm 11 Potable water DHW Cold water Primary flow Primary return Heating flow Heating return mains Flow performance 100 90 80 600mm 210mm Key 1 Stainless steel plate heat exchanger 2 Proportional Modulation Valve (PMV) 3 Flow restrictor disc 17 l/min 4 Bleed point 5 Zone valve (space heating control unit optional) 6 Balancer or Differential Pressure Control Valve (DPCV) optional 7 Thermostatic circulation bridge 45...65ºC optional 8 Spool piece for heat meter (L=110mm, 2 x ¾" outer thread) 9 ½" blind plug to be replaced by temp. sensor pocket for flow sensor (heat meter) 10 Strainer 11 Isolating ball valve ¾" female connection optional 12 Male connection/thread spool piece for cold water meter (L=110mm, 2 x ¾" outer thread) optional 13 Blending valve (thermostatic hot water mixing valve) optional 70 17L of DHW @ 60ºC Primary flow degrees ºC 60 50 40 17L of DHW @ 50ºC 17L of DHW @ 45ºC 30 20 10 46.6kW/cold water 10ºC 53.2kW/cold water 10ºC 65.6kW/cold water 10ºC *The primary flow should not exceed 1,000 l/h 0 0 500 1000 1500 2000 2500 3000 3500 Primary flow rate l/h* 25

PRODUCT DETAILS MEIBES HIU INDIRECT UNIT FOR UFH AND CYLINDERS A1 CX BLU-CLIMATE RANGE 26

MEIBES HIU A1 CX BLU-CLIMATE RANGE A1 CX units are for use with a separate hot water cylinder and have the capacity to serve apartments with two bathrooms. FEATURES & BENEFITS Designed to suit projects where stored water is preferred Compatible with pre-plumbed unvented cylinders Complete with heat meter Available with case with window for viewing heat meter Also available without case for fitting within an existing cabinet Includes high specification Differential Pressure Control Valve Top connections for easy contractor access Flow and primary return test points included Built-in strainer for unit. 687972 687974 A1 CX Blu-Climate HIU range options HIU model With box With heat meter Code Meibes A1 CX Blu-Climate HIU 20K DH & HW HM Yes Yes 687970 Meibes A1 CX Blu-Climate HIU 20K DH & HW Yes No 687971 Meibes A1 CX Blu-Climate HIU 20K DH & HW HM B No Yes 687972 Meibes A1 CX Blu-Climate HIU 20K DH & HW B No No 687974 A1 CX Blu-Climate HIU accessory options Accessory Code Meibes A1 CX Fix Rail 687424 Meibes A1 CX Fix Rail and Bypass 687485 27

PRODUCT DETAILS MEIBES HIU TECHNICAL & PERFORMANCE DATA A1 CX BLU-CLIMATE RANGE A1 CX Blu-Climate HIU Technical data Description Construction Duty (primary) Type Mounting Size (WxDxH, height of the case) Heating system Pipework Plate heat exchanger Casing Primary fluid Secondary fluid District heating station to be installed in conjunction with a pre-plumbed unvented cylinder Wall mounted with top or bottom connections 400 x 180 x 500mm 2 pipe flow Fully insulated flexible stainless steel with brass fittings Fully insulated stainless steel White powder coated sheet steel cover with viewing window for the heat meter Low pressure hot water Low pressure hot water Heat transfer capacity 20kW max. @ 30K ΔT (500 l/h) Fluid temperature flow 65ºC @ 70ºC primary flow Fluid temperature return 40ºC Maximum primary pressure 10bar Pressure Maximum secondary pressure 3bar Connections All external connections ¾" female ball valves 4x: optional First fix rail Fittings primary side Strainer Test points Sensor pocket Heat meter Solenoid valve (optional) Differential Pressure Control Valve (DPCV) Air vents Zone valve On primary flow Binder style test points Primary flow temperature sensor for heat meter Rossweiner HeatSonic M-Bus heat meter with permanent display Not pre-fitted fitted via removable spool piece Factory set at 30kPa (maximum differential pressure 250kPa) Manual Fitted with electrical actuator head maximum differential pressure 100kPa (kvs=1.85) 28

Dimensions and clearances Hydraulic layout Secondary side Primary side Return Flow Flow Return 8 8 8 8 1 1 2 5 M W 500mm 3 6 7 4 9 M 400mm 180mm Key 1 Test points 2 Strainer 3 Spool piece for heat meter (L=110mm, 2 x ¾" outer thread) 4 Differential Pressure Control Valve (DPCV) 5 Zone valve 6 Plate heat exchanger 7 Bleed points 8 ¾" ball valves (not illustrated) 9 Solenoid valve (optional) 29

MEIBES HEAT INTERFACE UNIT TECHNICAL GLOSSARY Meibes heat interface unit Features Designed specifically for UK Top entry connections First fix rail All pipework is pre-insulated Integrated Differential Pressure Control Valve (DPCV) Vertically mounted, un-insulated Domestic Hot Water heat exchanger (DHW) Proportional Modulating Valve (PMV) Carbon coated operating rod in PM valve, with ceramic disk Indirect energy supply No demand no flow A-rated pump Blending valve Trickle bypass (included) Performance based on lower primary flow temperatures 65ºC Return temperature limited (RTL) valve Optional factory fitted, heat meter Potable water circuit Warranties Designed for ease of servicing Reduced lifecycle costs Flexible stainless steel pipework Test points Strainers on primary and secondary circuits Vertically mounted insulated heat exchanger for heating circuit Simple, straightforward control wiring Benefits Designed to meet UK requirements to avoid installation and performance issues. Comprehensive spare stocks available in UK. Top entry pipework facilitates pipework runs in ceiling voids for quicker, simpler and more cost effective connection. Enables faster installation and facilitates staged installation to suit the project timetable and contractor s schedule. Also allows earlier primary testing of the main heat network. The first fix rail allows all plumbing connections to be made, pressure tested, flushed and filled before installation of the main unit, thereby reducing risk of damage and supporting staged applications for payment where appropriate. Minimises heat loss for higher energy efficiency, while also improving end user comfort by preventing heat transfer to property during summer. Integrated DPCV make the system self balancing and ensures each unit only draws as much energy/flow as it requires in conjunction with a Proportional Modulating Valve. Results in a simpler design with improved control and less noise. Uninsulated vertical heat exchanger accelerates cooling of DHW heat exchanger through convection and thermal radiation, minimising limescale formation, maintaining high performance and extending life of units. Gives priority to DHW generation over space heating to ensure full DHW performance. Primary flow rates are matched to cold water input. Carbon coating provides self lubricating operation, with ceramic disc removing limescale each time the valve operates to deliver a longer, trouble free, service life. Separates main primary circuit from secondary circuits, ensuring issues in either do not impact on the other. Also provides clear demarcation where different contractors are used for primary and secondary circuit installation. With no demand for hot water or heating the unit is effectively on standby with no flow (see trickle bypass). Minimises demand on main network, reduces energy costs and avoids overheating of space where unit is fitted. The electronic pump is an A-rated Wilo pump which delivers energy-savings due to only using the minimum amount of electricity. Controls maximum temperature of DHW from the heat exchanger at 60ºC. The blend valve allows the temperature to adjust from 60ºC down to 35ºC depending on the application requirement. Ensures that the prime flow is hot when the unit is switched off, ensuring quicker response times for DHW demand and eliminating cold legs in network where HIUs are some distance from the main network. Avoids need for bypasses on risers, thereby simplifying network design. Ensures maximum performance with condensing boilers and supports use of low carbon heat sources (e.g. heat pumps) with lower primary flow temperatures. An optional RTL is available if required to allow the return temperature to be limited. This protects the boiler from excessive temperatures. Allows accurate measurement of individual energy use. Pressure tested and fitted at factory, reducing on site labour and risk. Range of options to suit project requirements ultrasonic or mechanical. M-Bus, radio, manual reading, prepayment. WRAS approved to meet UK requirements and compliant with European Drinking Water directive, in line with Pegler Yorkshire s commitment to highest quality and safety. 2 year warranty on the unit and moving parts such as pump (on selected units). Ease of access to all components ensures annual servicing can be completed quickly and efficiently. Product quality and ease of servicing ensure minimal cost of ownership with sustained high efficiency and performance. Reduces thermal expansion stresses for quieter operation during warm up and cool down. Easier future servicing due to flat face connections. In the unlikely event of a need for component replacement, flexible pipework makes re-connection easier. Allows confirmation of flow pressure and temperature. Help to capture debris from either circuit, thereby protecting heat exchangers and/or other components, as well as extending service life. Strainer cleaning is included in annual servicing. Ensures heating circuit heat exchanger remains at temperature without introducing heat to the unit. Lack of cycling and appropriate water treatments ensure that limescaling is not an issue. External control wiring is similar to a conventional combi boiler and therefore familiar to installers. 30

Indirect system A2 RX/A2 UX Direct system A1 RX Indirect for cylinder system A1 CX 31

DISTRICT HEATING SYSTEMS CLIMATE CONTROL Connect with confidence 1 2 3 Market-leading Cost effective Highly versatile metal push-fit Exceptional performance press-fit for the widest variety of applications. Strong, reliable press-fit with simple, heat-free installation 2 MEIBES BLU-CLIMATE A2 RX HIU Indirect DHW Indirect SH HEAT INTERFACE UNIT 1 5 5 MEIBES BLU-CLIMATE A2 UX HIU 1 Indirect DHW Indirect SH HEAT INTERFACE UNIT MEIBES BLU-CLIMATE A1 RX HIU Indirect DHW Direct SH 1 HEAT INTERFACE UNIT 5 5 4 MEIBES BLU-CLIMATE A1 CX HIU Indirect DHW Indirect SH 1 HEAT INTERFACE UNIT DHW CYLINDER 5 5 MICRO CHP BIOMASS GAS DATA EXTRACTION UNIT Mains water Primary flow Primary return Heating flow Heating return Potable water DHW flow 32

HEAT EMITTER 6 6 5 5 6 DHW flow 3 6 6 UNDERFLOOR HEATING CIRCUIT 6 DHW flow HEAT EMITTER 6 6 5 5 6 DHW flow 6 HEAT EMITTER 6 5 5 6 DHW flow Putting you in control 4 5 6 Commission and system balancing that optimises building system performance Energy-saving radiator valves that maximise comfort Elegantly designed, exceptional quality taps and showers 33

34 NOTES

35

Pegler Yorkshire Follow us on UK ENQUIRIES UK SALES Free Phone: 0800 156 0010 Free Fax: 0808 156 1011 Email: uk.sales@pegleryorkshire.co.uk TECHNICAL HELP Free Phone: 0800 156 0050 Free Fax: 0808 156 1012 Email: tech.help@pegleryorkshire.co.uk BROCHURE HOTLINE Free Phone: 0800 156 0020 Free Fax: 0808 156 1011 Email: info@pegleryorkshire.co.uk INTERNATIONAL ENQUIRIES EXPORT Tel: +44 (0) 1302 855 656 Fax: +44 (0) 1302 730 513 Email: export@pegleryorkshire.co.uk HEAD OFFICE Pegler Yorkshire Group Limited St. Catherine s Avenue, Doncaster, South Yorkshire DN4 8DF, England Tel: +44 (0) 844 243 4400 Fax: +44 (0) 844 243 9870 Email: info@pegleryorkshire.co.uk www.pegleryorkshire.co.uk Registered in England Company No. 00401507 All brand names and logo styles are registered trademarks. Maintaining a policy of continual product development, Pegler Yorkshire reserves the right to change specifications, design and materials of products listed in this publication without prior notice LIT.REF: 880153.03.14