Heating Version 1. Pricelist

Similar documents
Heating 2014 Pricelist

Pricelist. Heating. All seasons Perfect c mfort

Daikin Altherma. : 11, 14, 16 kw. : 11, 14 and 16 kw

The natural. hoice installer leaflet. DAikin Altherma low-temperature heat pump. Preliminary version

Heating. Daikin Altherma Flex Type. Catalogue ALL SEASONS PERFECT C MFORT. Centralised 3-in-1 heating solution with the scope for individuality

Pricelist Heating Prices and technical information for Heating products

The natural. hoice installer leaflet. DAikin Altherma low temperature heat pump

Heating. Pricelist Heating PERFECT C MFORT. Catalogue. All seasons PERFECT C MFORT. Heating. Air Conditioning. Applied Systems.

High temperature hydrobox for VRV

The natural ombination

Daikin UK Price List. Heating and Renewables FEATURING THE NEW GAS CONDENSING BOILER. Update: Valid from 1st January 2017

Daikin Altherma Low Temperature monobloc heat pump

Daikin Altherma hybrid heat pump. The natural combination

The natural fit, all-in-one. Daikin Altherma monobloc heat pump for the installer

All-in-one solution for residential. heating. Keep the technical equipment outside. Only cosiness stays inside. The new Daikin Altherma Monobloc

A +++ R32 Daikin Altherma 3 powered by Bluevolution. Why choose Daikin Altherma 3? 65 C

Daikin Altherma Low Temperature monobloc heat pump

Heating. Catalogue. Climate comfort. All seasons. Heating. Air conditioning. Applied Systems. Refrigeration. Heating - Domestic hot water - Cooling

Heating. Catalogue. Climate comfort. All Seasons. For end users. Heating. Air Conditioning. Applied Systems. Refrigeration

Daikin Altherma 3. Product catalogue Setting the new heat pump standard

Heating. Why choose a Daikin heating system? 20. Products overview 24. Combination tables 26. Options & accessories 74

Daikin Altherma 3. Product catalogue Setting the new heat pump standard

All-in-one comfort for residential applications. Product catalogue Heating

High temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water

Heating. Catalogue. Climate comfort. All seasons. Heating. Air conditioning. Industrial Application. Refrigeration

Daikin Altherma 3 EPGA-D kw

Simply renewable A ++ A +++ ROTEX air-to-water heat pump

Heating - Domestic hot water - Cooling. the intelligent way to comfort

THE HEAT PUMP CHOICE OF PROFESSIONALS

Split Type System. Air to Water Heat Pump

Natural geothermal energy

Do you want a versatile solution

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Simply renewable A ++ A +++ ROTEX air-to-water heat pump

DACA-EEDEN technical data. Engineering Data. DaikinAltherma

Air-to-water heat pump systems

Heating - Domestic hot water - Cooling. THE AIR to WATER HEAT PUMPS

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved.

The Future of Central Heating Today. Air source heat pump systems

Daikin Altherma Selection Report

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

ROTEX Products Prices and specifications 04/2014

Air to water Heat Pump System

EEDEN technical data ERHQ AA

A strong team A ++ A +++ ROTEX gas hybrid heat pump

Heating. Technical Data EEDEN ERRQ-AY1

FREQUENTLY ASKED QUESTIONS

your comfort. our world. Heating Catalogue Energy-efficient & renewable solutions

Daikin Altherma Hybrid Heat Pump

50A KP 70A KP 90A KP 120A KP 150A KP 210A

Prices and technical information for Applied Systems. Pricelist Applied Systems

White paper: New Ecodesign rules and energy labelling for space and water heaters

Heating Range. Next generation of renewable solutions. your comfort. our world. Heating. Ventilation. Integrated Solutions.

Advance Split

Air Conditioners Heating & Cooling

Operation manual. Daikin Altherma Low temperature split EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV

Operation manual. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

Air Conditioners Heating & Cooling

TABLE OF CONTENTS ERSQ-AAY1

HITACHI line up: YUTAKI S 80 Very high water temperature Heat Pump

Air Conditioners Heating & Cooling

Air to water Heat Pump System

NATURAL HEATING MACHINE

Create the right atmosphere with renewables

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

ROTEX air-to-water heat pump powered by Bluevolution The new heat pump generation

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

HEATING HEA TING

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Air-water heat pump. Hydronic terminals. HYDROLution NEW 172 SINGLE HT 176 DUAL HT 178 MINI CHILLER 180 MODULAR CHILLER 182 WARM COIL 184 FAN COIL 186

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

Heat Pump Water Heater Commercial Leaflet 2012

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

Heating Range. Next generation of renewable solutions. your comfort. our world. Heating. Ventilation. Integrated Solutions.

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

A strong team A ++ A +++ ROTEX gas hybrid heat pump

TABLE OF CONTENTS EKHTS-A

Air Conditioners Heating & Cooling

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Heating Range. Energy-efficient and renewable solutions. your comfort. our world.

Oilon Ground Source Heat Pumps

EEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Efficient heating that won t cost the earth

HEAT PUMPS LINE AS AIR TO WATER

WHY A MHI HEAT PUMP?

Produced by the Residential Solution Sales Division. Daikin AC Americas, Inc.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

Europe s first light commercial cassette system using R-32 refrigerant. Our mission The lowest environmental impact

Transcription:

Heating 215 Version 1 Pricelist

Table of contents Daikin Altherma low temperature split NEW! System Introduction 4 Technical Specifications 6 Pricelist 8 Daikin Altherma low temperature monobloc System Introduction 1 Technical Specifications 12 Pricelist 14 Daikin Altherma high temperature System Introduction 16 Technical Specifications 18 Pricelist 2 Daikin Altherma hybrid heat pump System Introduction 22 Technical Specifications 24 Pricelist 25 Flue Gas System 26 Daikin Altherma ground source heat pump System Introduction 28 Technical Specifications 3 Pricelist 31 Daikin Altherma Flex Type System Introduction 32 Technical Specifications 34 Pricelist 36 Daikin heat pump convector System Introduction 38 Technical Specifications 39 Pricelist 39 Daikin solar system System Introduction 4 Technical Specifications 42 Pricelist 43 NOTES The pricelist is valid from 15. April 215. All prior pricelists are not valid anymore. All prices are list prices in Euro and excl. VAT. The Daikin Commercial Terms and Conditions apply (see last page or http://www.daikin-ce.com). We reserve the right for printing errors and model changes. 2

You and your customer have decided to switch to an energy-efficient heating system that produces low CO 2 emissions. Daikin Altherma is a total heating and domestic hot water system based on air source heat pump technology. One that represents a flexible and cost-effective alternative to a fossil fuel boiler. It also has an option for cooling.* The inherent energy-efficiency characteristics of Daikin Altherma make it an ideal solution for reduced energy consumption and low CO 2 emissions. Its high- and low-temperature heating systems provide optimal comfort. Highly energy-efficient heat pumps with advanced compressor technology transform unused and inexhaustible heat from the surrounding air into usable heat, either as part of the overall climate-control system or to heat domestic hot water. Moreover, the system is easy to install. *The Daikin Altherma cooling option is available for low-temperature heating systems (under floor heating system, heat pump convectors). 3

Daikin Altherma low temperature split Best seasonal efficiencies, COP up to 4,2 A2/W35 (according to EN14511) Perfect fit providing the highest savings on running costs and CO 2 emissions. for new builds, as well as for low-energy houses High heat pump efficiencies at all outdoor and water temperatures guarantee low running costs and low CO 2 emissions. High heating capacities enable best efficiencies down to low outside temperature. The electrical back-up heater assistance is no longer required or only very limited. Daikin inverter compressors with high modulation range provide: Higher compressor efficiency in partial load operation. Delivered capacities exactly matching the actual heating demand of the building. Obtaining the capacities needed with minimum energy consumption. Less on/off operation, increasing the operation life cycle of the compressor. Limiting electrical inputs of auxiliary components contribute to the high seasonal efficiencies: Factory-mounted high efficiency circulating pump already qualifying for future regulations (ErP215) with an A-energy label (EEI.23) No standby losses of inverter drive PCB, lowering electricity consumption during standby mode No bottom plate heater needed on 4-8kW class Low-capacity bottom plate heater on 11-16kW class (ERLQ-C series), only operating during defrost cycles. NEW: Optimised unit for low heat loads available The new-build house market in Europe is moving towards smaller heat loads, due to: Growing importance of low-energy houses Strengthened legislation on energy consumption in new residential constructions (e.g. EPBD regulations) Decreasing size of new-build houses EU member states planning to reach their 2-2-2 targets The new Daikin Altherma low temperature is designed to meet the requirements of newly built and low-energy houses characterised by low heat loads. With capacities from 4 to 16kW Daikin Altherma covers 9% of all new built applications. All types of heat emitters are possible: Under-floor heating: 25 C 35 C Heat pump convector: 35 C 45 C Low temperature radiators: 4 C 5 C Daikin Altherma is suitable for all climates, even withstanding severe winter conditions. 4

Daikin Altherma low temperature split Integrated indoor unit: best solution for domestic hot water for installer & customer User interface: high functionalities, easy to use Easiest and fastest installation, domestic hot water tank included Fast installation: the stainless steel domestic hot water tank is included in the unit, with all connections between heat pump module and tank factory made. All hydraulic components are included. Lower installation footprint. Minimised installation space, both in terms of footprint and height: Small footprint with a width of only 6cm and a depth of 74cm The required installation height is less than 2m Sleek design and modern look Best solution for domestic hot water 6 cm heating with high efficiency and high comfort 5% less heat loss compared to a standard insulated tank. High hot water volumes: 3l at 4 C, enough for 6 showers without any electrical assistance. Wall-mounted indoor unit including all hydraulic components. 74 cm Quick and easy commissioning: Quick configuration wizard to guide installer through commissioning process Menu-based navigation to fine-tune the basic parameters Parameters are up- and downloadable from/to PC Actuator test mode to activate all wired components one by one Automatic screed-drying function Room temperature control functionality: The user interface itself is equipped with a temperature sensor and can be directly used as a rom thermostat, resulting in more stable room temperatures, increased efficiency and operation life cycle. User-friendly with intuitive control: The large graphical interface allows an intuitive and self-explanatory menu Provides additional information such as the energy consumption and heat production of the system Graphical screen with backlight Error info On/Off Home Menu back Confirm Navigational buttons 5

Daikin Altherma low temperature split Technical specifications OUTDOOR UNIT ERLQ4CV3 ERLQ6CV3 ERLQ8CV3 Heating capacity Min. kw 1,8 1 1,8 1 1,8 1 Nom. kw 4,4 1 / 3,27 2 6, 1 / 4,58 2 7,4 1 / 5,8 2 Max. kw 5,12 1 8,35 1 1,2 1 Cooling capacity Nom. kw 5, 3 / 4,17 4 6,76 3 / 4,84 4 6,86 3 / 5,36 4 COP nom. 5,4 1 / 4,2 2 4,74 1 / 3,68 2 4,45 1 / 3,53 2 EER nom. 3,37 3 / 2,32 4 3,45 3 / 2,34 4 3,42 3 / 2,29 4 Dimensions Unit H x W x D mm 735x832x37 735x832x37 735x832x37 Operation range Heating Min.~Max. C -25~25-25~25-25~25 Cooling Min.~Max. C 1~43 1~43 1~43 Domestic hot water Min.~Max. C -25~35-25~35-25~35 Sound pressure level* Heating Nom. dba 48 48 49 Cooling Nom. dba 48 49 5 Power supply (phase/voltage) 1~/23V 1~/23V 1~/23V Heating only INDOOR UNIT - WALL MOUNTED EHBH4CB3V EHBH8CB3V EHBH8CB9W Dimensions Unit H x W x D mm 89x48x344 89x48x344 Operation range Heating Water side Min.~Max. C 15~55 15~55 Domestic hot water Water side Min.~Max. C 25~8 25~8 Sound pressure level* Nom. dba 26 26 Power supply (phase/voltage) 1~/23V 1~/23V / 3~/4V Heating & Cooling INDOOR UNIT - WALL MOUNTED EHBX4CB3V EHBX8CB3V EHBX8CB9W Dimensions Unit H x W x D mm 89x48x344 89x48x344 Operation range Heating Water side Min.~Max. C 15~55 15~55 Cooling Water side Min.~Max. C 5~22 5~22 Domestic hot water Water side Min.~Max. C 25~8 25~8 Sound pressure level* Nom. dba 26 26 Power supply (phase/voltage) 1~/23V 1~/23V / 3~/4V Heating only INDOOR UNIT - FLOORSTANDING EHVH4S18CB3V EHVH8S18CB3V EHVH8S26CB9W Dimensions Unit H x W x D mm 1.732x6x728 1.732x6x728 Operation range Heating Water side Min.~Max. C 15~55 15~55 Domestic hot water Water side Min.~Max. C 25~6 25~6 Sound pressure level* Nom. dba 28 28 Power supply (phase/voltage) 1~/23V 1~/23V / 3~/4V Heating & Cooling INDOOR UNIT - FLOORSTANDING EHVX4S18CB3V EHVX8S18CB3V EHVX8S26CB9W Dimensions Unit H x W x D mm 1.732x6x728 1.732x6x728 Operation range Heating Water side Min.~Max. C 15~55 15~55 Cooling Water side Min.~Max. C 5~22 5~22 Domestic hot water Water side Min.~Max. C 25~6 25~6 Sound pressure level* Nom. dba 28 28 Power supply (phase/voltage) 1~/23V 1~/23V / 3~/4V 6

Daikin Altherma low temperature split ERLQ11CV3 / ERLQ11CW1 ERLQ14CV3 / ERLQ14CW1 ERLQ16CV3 / ERLQ16CW1 11,2 1 / 8,56 2 14,5 1 / 1,3 2 16, 1 / 11,1 2 11,38 1 14,55 1 16,1 1 15,5 3 / 11,72 4 16,6 3 / 12,55 4 16,76 3 / 13,12 4 4,6 1 / 3,6 2 4,3 1 / 3,45 2 4,25 1 / 3,35 2 3,32 3 / 2,72 4 2,96 3 / 2,47 4 2,72 3 / 2,29 4 1.345x9x32 1.345x9x32 1.345x9x32-25~35-25~35-25~35 1~46 1~46 1~46-2~35-2~35-2~35 51 51 52 5 52 54 1~/23V / 3~/4V 1~/23V / 3~/4V 1~/23V / 3~/4V EHBH11CB3V EHBH11CB9W* EHBH16CB3V EHBH16CB9W* 89x48x344 89x48x344 25~55 25~55 25~8 25~8 33 33 1~/23V / *3~/4V 1~/23V / *3~/4V EHBX11CB3V EHBX11CB9W* EHBX16CB3V EHBX16CB9W* 89x48x344 89x48x344 15~55 15~55 5~22 5~22 25~8 25~8 33 33 1~/23V / *3~/4V 1~/23V / *3~/4V EHVH11S18CB3V EHVH11S26CB9W* EHVH16S18CB3V EHVH16S26CB9W* 1.732x6x728 1.732x6x728 15~55 15~55 25~6 25~6 33 33 1~/23V / *3~/4V 1~/23V / *3~/4V EHVX11S18CB3V EHVX11S26CB9W* EHVX16S18CB3V EHVX16S26CB9W* 1.732x6x728 1.732x6x728 15~55 15~55 5~22 5~22 25~6 25~6 33 33 1~/23V / *3~/4V 1~/23V / *3~/4V *Measured in 1m distance from the unit. (1) EW 3 C; LW 35 C; ambient conditions: 7 CDB/6 CWB (2) EW 3 C; LW 35 C; ambient conditions: 2 CDB/1 CWB (3) EW 23 C; LW18 C; ambient conditions: 35 C (4) EW 12 C; LW 7 C; ambient conditions 35 C 7

Daikin Altherma low temperature split Pricelist Daikin Altherma is a low temperature, inverter driven air to water split heat pump system. The outdoor unit is connected to the indoor unit (wallmounted or floorstanding) with refrigerant piping. The heat pump system can be used for space heating, space cooling and domestic hot water production. Daikin Altherma Low Temperature Outdoor Unit Inverter Split Heat pump outdoor unit with nominal capacities from 4 to 8 kw. Nominal capacity is measured at A7/W35**. Daikin Altherma 4 kw outdoor unit* ERLQ4CV3 Power Supply 1~ 23V 1.618,- Daikin Altherma 6 kw outdoor unit ERLQ6CV3 Power Supply 1~ 23V 1.699,- Daikin Altherma 8 kw outdoor unit ERLQ8CV3 Power Supply 1~ 23V 2.99,- Daikin Altherma wallmounted indoor unit for heating only applications. Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included. Wallmounted indoor unit 4kW with 3kW BUH* EHBH4CB3V Electrical Backup Heater 1~ 23V 2.483,- Wallmounted indoor unit 6-8 kw with 3kW BUH EHBH8CB3V Electrical Backup Heater 1~ 23V 2.549,- Wallmounted indoor unit 6-8kW with 3-9 kw BUH EHBH8CB9W Electrical Backup Heater 1~ 23V or 3~ 4V 2.678,- Daikin Altherma wallmounted indoor unit for heating & cooling applications. Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included. Wallmounted indoor unit 4kW with 3kW BUH* EHBX4CB3V Electrical Backup Heater 1~ 23V 2.71,- Wallmounted indoor unit 6-8 kw with 3kW BUH EHBX8CB3V Electrical Backup Heater 1~ 23V 2.812,- Wallmounted indoor unit 6-8kW with 3-9 kw BUH EHBX8CB9W Electrical Backup Heater 1~ 23V or 3~ 4V 2.84,- Daikin Altherma Indoor unit (floorstanding with domestic hot water tank) for heating only applications. Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included. Floorstanding indoor unit 4kW with 3kW BUH & 18L Tank* EHVH4S18CB3V Electrical Backup Heater 1~ 23V 3.821,- Floorstanding indoor unit 6-8 kw with 3kW BUH & 18L Tank EHVH8S18CB3V Electrical Backup Heater 1~ 23V 3.923,- Floorstanding indoor unit 6-8kW with 3-9 kw BUH & 26L Tank EHVH8S26CB9W Electrical Backup Heater 1~ 23V or 3~ 4V 4.15,- Daikin Altherma Indoor unit (floorstanding with domestic hot water tank) for heating & cooling applications. Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included. Floorstanding indoor unit 4kW with 3kW BUH & 18L Tank* EHVX4S18CB3V Electrical Backup Heater 1~ 23V 3.891,- Floorstanding indoor unit 6-8 kw with 3kW BUH & 18L Tank EHVX8S18CB3V Electrical Backup Heater 1~ 23V 3.993,- Floorstanding indoor unit 6-8kW with 3-9 kw BUH & 26L Tank EHVX8S26CB9W Electrical Backup Heater 1~ 23V or 3~ 4V 4.233,- Daikin Altherma Low Temperature Outdoor Unit Inverter Split Heat pump outdoor unit with nominal capacities from 11 to 16 kw. Nominal capacity is measured at A7/W35** Daikin Altherma 11 kw outdoor unit ERLQ11CV3 Power Supply 1~ 23V 3.77,- Daikin Altherma 14 kw outdoor unit ERLQ14CV3 Power Supply 1~ 23V 3.677,- Daikin Altherma 16 kw outdoor unit ERLQ16CV3 Power Supply 1~ 23V 3.987,- Daikin Altherma Low Temperature Outdoor Unit Inverter Split Heat pump outdoor unit with nominal capacities from 11 to 16 kw. Nominal capacity is measured at A7/W35**. Daikin Altherma 11 kw outdoor unit ERLQ11CW1 Power Supply 3~ 4V 3.523,- Daikin Altherma 14 kw outdoor unit ERLQ14CW1 Power Supply 3~ 4V 4.164,- Daikin Altherma 16 kw outdoor unit ERLQ16CW1 Power Supply 3~ 4V 4.57,- Daikin Altherma wallmounted indoor unit for heating only applications. Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included. Wallmounted indoor unit 11kW with 3KW BUH EHBH11CB3V Electrical Backup Heater 1~ 23V 2.674,- Wallmounted indoor unit 11 kw with 3-9 kw BUH EHBH11CB9W Electrical Backup Heater 1~ 23V or 3~ 4V 2.853,- Wallmounted indoor unit 16 kw with 3 kw BUH EHBH16CB3V Electrical Backup Heater 1~ 23V 2.942,- Wallmounted indoor unit 16 kw with 3-9 kw BUH EHBH16CB9W Electrical Backup Heater 1~ 23V or 3~ 4V 3.171,- Daikin Altherma wallmounted indoor unit for heating & cooling applications. Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included. Wallmounted indoor unit 11kW with 3KW BUH EHBX11CB3V Electrical Backup Heater 1~ 23V 2.938,- Wallmounted indoor unit 11 kw with 3-9 kw BUH EHBX11CB9W Electrical Backup Heater 1~ 23V or 3~ 4V 3.71,- Wallmounted indoor unit 16 kw with 3 kw BUH EHBX16CB3V Electrical Backup Heater 1~ 23V 3.27,- Wallmounted indoor unit 16 kw with 3-9 kw BUH EHBX16CB9W Electrical Backup Heater 1~ 23V or 3~ 4V 3.445,- Daikin Altherma Indoor unit (floorstanding with domestic hot water tank) for heating only applications. Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included. Floorstanding indoor unit 11 kw with 3kW BUH & 18 L Tank EHVH11S18CB3V Electrical Backup Heater 1~ 23V 4.34,- Floorstanding indoor unit 11 kw with 3-9 kw BUH & 26 L Tank EHVH11S26CB9W Electrical Backup Heater 1~ 23V or 3~ 4V 4.18,- Floorstanding indoor unit 16 kw with 3kW BUH & 18L Tank EHVH16S18CB3V Electrical Backup Heater 1~ 23V 4.28,- Floorstanding indoor unit 16 kw with 3-9 kw BUH & 26 L Tank EHVH16S26CB9W Electrical Backup Heater 1~ 23V or 3~ 4V 4.38,- 8

Daikin Altherma low temperature split Controller and User Interface, mandatory for each *CB unit. (Other languages you will find on page 25) Combinations OUTDOOR UNIT EHBH4CB3V EHBX4CB3V Applicable for: Controller EKRUCBL1 User interface with languages FR, NL, DE, IT 143,- Controller EKRUCBL2 User interface with languages EN, SV, FI, NO 143,- Options & Accessories Drainpan for outdoor unit (exl. drainpan heater) Daikin Altherma Indoor unit (floorstanding with domestic hot water tank) for heating & cooling applications. Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included. Floorstanding indoor unit 11 kw with 3 kw BUH & 18 L Tank EHVX11S18CB3V Electrical Backup Heater 1~ 23V 4.181,- Floorstanding indoor unit 11 kw with 3-9 kw BUH & 26 L Tank EHVX11S26CB9W Electrical Backup Heater 1~ 23V or 3~ 4V 4.399,- Floorstanding indoor unit 16 kw with 3kW BUH & 18L Tank EHVX16S18CB3V Electrical Backup Heater 1~ 23V 4.48,- Floorstanding indoor unit 16 kw with 3-9 kw BUH & 26 L Tank EHVX16S26CB9W Electrical Backup Heater 1~ 23V or 3~ 4V 4.564,- * The 4kW outdoor ERLQ4CV3 unit can only be combined with a 4kW indoor unit (either wallmounted or floorstanding)! ** Ta DB/WB 7 C / 6 C - LWC 35 C (DT = 5K) EKDP8C Collect water from defrost cycle and drain via central hole to remote location. If installed additional heater tape EKDPHbC is mandatory! INDOOR UNIT Wallmounted Floorstanding Wallmounted Floorstanding EHBH8CB3V EHBH8CB9W EHVH4S18CB3V EHVH8S18CB3V EHVH8S26CB9W EHBH11CB* EHBH16CB* EHVH11S18CB* EHBX8CB3V EHBX8CB9W EHVX4S18CB3V EHVX8S18CB3V EHVX8S26CB9W EHBX11CB* EHBX16CB* EHVX11S18CB* EHVH16S26CB* EHVX16S26CB* ERLQ4CV3 ERLQ6CV3 ERLQ8CV3 ERLQ11CV3 ERLQ14CV3 ERLQ16CV3 ERLQ11CW1 ERLQ14CW1 ERLQ16CW1 4-8kW 11-16kW Applicable for: 4-8kW 11-16kW 168,- Heater tape for outdoor unit drainpan EKDPH8C Heater tape to install in central hole of drain pan to prevent ice blockage 255,- Remote temperature sensor for outdoor unit EKRSC1 Ambient temperature measurement remotely from outdoor unit 88,- U-beams for outdoor unit EKFT8CA Beams to mount outdoor unit on (height 25cm) 135,- Remote indoor sensor KRCS1-1 Temperature measurement remotely from user interface 82,- PC cable EKPCCAB2 Cable to upload field settings from PC to unit 255,- Drain pan kit for indoor unit EKHBDPC2 Collect and drain condensate during cooling operation 152,- Wired room thermostat EKRTWA Wired Digital Room Thermostat 145,- Wireless room thermostat EKRTR Wireless Digital Room Thermostat 286,- Thermostat external sensor EKRTETS Temperature measurement remotely from wireless room thermostat (e.g. floor temperature) 17,- Digital I/O PCB EKRP1HBA Remote alarm / operation status 152,- Demand PCB EKRP1AHT Power consumption limitation with 4 digital inputs on hydrobox 151,- Demand PCB KRP58M51 Power consumption limitation via outdoor unit 28,- Solar Kit EKSOLHW Heat exchanger to connect Daikin solar system to EKHWS and EKHWE DHW tank 851,- Electricity meter K.ELECMETV Single phase electricity meter 179,- Electricity meter K.ELECMETW Three phase electricity meter 374,- Domestic hot water connection kit for EKHWP3B H/O EKDVCPLT3H/X Connection kit for LT 4-8kW in combination with EKHWP3B 31,- Domestic hot water connection kit for EKHWP5B H/O EKDVCPLT5H Connection kit for LT 4-16kW heating only in combination with EKHWP5B 554,- Domestic hot water connection kit for EKHWP5B H/C EKDVCPLT5X Connection kit for LT 4-16kW heating & cooling in combination with EKHWP5B 735,- Electrical Booster Heater EKBH3S Electrical booster heat for EKHWP-B tanks 361,- Domestic Hot Water Tank Sets (consists of tank, booster heater, contactor/fuse assembly for BH, tanksensor + 12m connection wire, 3 Way Valve + motor) Applicable for: 4-8kW 11-16kW Stainless Steel Domestic Hot Water Tank 15L EKHWS15B3V3 incl. 3kW booster heater 1~ 23V, height 9mm, diameter 58mm, weight 37kg 1.5,- Wallbracket for 15L stainless steel tank EKWBSWW15 32,- Stainless Steel Domestic Hot Water Tank 2L EKHWS2B3V3 incl. 3kW booster heater 1~ 23V, height 115mm, diameter 58mm, weight 45kg 1.84,- Stainless Steel Domestic Hot Water Tank 2L EKHWS2B3Z2 incl. 3kW booster heater 2~ 4V, height 115mm, diameter 58mm, weight 45kg 1.84,- Stainless Steel Domestic Hot Water Tank 3L EKHWS3B3V3 incl. 3kW booster heater 1~ 23V, height 16mm, diameter 58mm, weight 59kg 1.225,- Stainless Steel Domestic Hot Water Tank 3L EKHWS3B3Z2 incl. 3kW booster heater 2~ 4V, height 16mm, diameter 58mm, weight 59kg 1.225,- Enameled Domestic Hot Water Tank 15L EKHWE15A3V3 incl. 3kW booster heater 1~ 23V, height 125mm, diameter 545mm, weight 8kg 875,- Enameled Domestic Hot Water Tank 15L (wallmounted) EKHWET15A3V3 incl. 3kW booster heater 1~ 23V, height 125mm, diameter 545mm, weight 82kg not relevant Enameled Domestic Hot Water Tank 2L EKHWE2A3V3 incl. 3kW booster heater 1~ 23V, height 158mm, diameter 545mm, weight 14kg 92,- Enameled Domestic Hot Water Tank 2L EKHWE2A3Z2 incl. 3kW booster heater 2~ 4V, height 158mm, diameter 545mm, weight 14kg 92,- Enameled Domestic Hot Water Tank 3L EKHWE3A3V3 incl. 3kW booster heater 1~ 23V, height 1572mm, diameter 66mm, weight 14kg 1.2,- Enameled Domestic Hot Water Tank 3L EKHWE3A3Z2 incl. 3kW booster heater 2~ 4V, height 1572mm, diameter 66mm, weight 14kg 1.2,- Domestic Hot Water Tanks with pressureless buffer tank and hygienic domestic hot water production (can be used for solar option) Applicable for: 4-8kW 11-16kW Pressureless 3L Domestic Hot Water Tank EKHWP3B Pressureless hygienic domestic hot water tank with solar option for 4-8 kw LT heat pumps 2.234,- Pressureless 5L Domestic Hot Water Tank EKHWP5B Pressureless hygienic domestic hot water tank with solar option for 4-16kW LT heat pumps 2.211,- *3V versions and 9W versions (1~ 23V and 3~ 4V versions) 9

1

Daikin Altherma low temperature monobloc Monobloc system Everything combined in one outdoor unit In addition to Daikin Altherma split systems, Daikin has introduced a monobloc version in which all hydraulic parts are located within the outdoor unit. In this system, the water pipes, rather than the refrigerant pipes, run indoors from the outdoor unit, making installation much quicker and easier for the domestic installer. Available capacities for monobloc: 11, 14, 16 kw Domestic hot water Solar connection (optional) Heat pump convector Outdoor unit: 11, 14 and 16 kw Under floor heating 11

Daikin Altherma low temperature monobloc Technical specifications Heating ONLY Single phase EDLQ11BC6V3 EDLQ14BC6V3 EDLQ16BC6V3 Heating capacity Nom. kw 11,2 1 / 8,11 2 14, 1 / 9,72 2 16, 1 / 1,69 2 Power input Heating Nom. kw 2,56 1 / 2,57 2 3,29 1 / 3,12 2 3,88 1 / 3,44 2 COP 4,38 1 / 3,16 2 4,25 1 / 3,12 2 4,12 1 / 3,11 2 Dimensions Unit Height X Width X Depth mm 1.418 X 1.435 X 382 Weight Unit kg 18 Hydraulic component Back-up Type heater current Power supply Phase/Frequency/ ~/Hz/V Voltage 1~/5/23 Operation range Heating Ambient Min.~Max. C -2~35 Water side Min.~Max. C 15 ~55 Domestic hot water Ambient Min.~Max. C -2~43 Water side Min.~Max. C 25~8 Refrigerant Type R-41A Charge kg 2,95 Sound power level Heating Nom. dba 64 65 66 Sound pressure level Heating Nom. dba 51 52 Compressor component Main power supply Name V3 Phase 1~ Frequency Hz 5 Voltage V 23 6V3 (1) cooling Ta 35 C - LWE 18 C (DT = 5 C); heating Ta DB/WB 7 C/6 C - LWC 35 C (DT = 5 C) (nom. values according to EN14511) (2) cooling Ta 35 C - LWE 7 C (DT = 5 C); heating Ta DB/WB 7 C/6 C - LWC 45 C (DT = 5 C) (nom. values according to EN14511) Heating ONLY Three phase EDLQ11BC6W1 EDLQ14BC6W1 EDLQ16BC6W1 Heating capacity Nom. kw 11,2 1 / 8,11 2 14, 1 / 9,72 2 16, 1 / 1,69 2 Power input Heating Nom. kw 2,6 1 / 2,61 2 3,3 1 / 3,13 2 3,81 1 / 3,44 2 COP 4,31 1 / 3,11 2 4,24 1 / 3,11 2 4,2 1 / 3,11 2 Dimensions Unit Height X Width X Depth mm 1.418 X 1.435 X 382 Weight Unit kg 18 Hydraulic Back-up Type 6W1 component heater current Power Phase/Frequency/ ~/Hz/V supply Voltage 3~/5/4 Operation range Heating Ambient Min.~Max. C -25~35 Water side Min.~Max. C 15 ~55 Domestic hot water Ambient Min.~Max. C -25~43 Water side Min.~Max. C 25~8 Refrigerant Type R-41A Charge kg 2,95 Sound power level Heating Nom. dba 64 65 66 Sound pressure level Heating Nom. dba 49 51 53 Compressor component Main power supply Name W1 Phase 3N~ Frequency Hz 5 Voltage V 4 (1) cooling Ta 35 C - LWE 18 C (DT = 5 C); heating Ta DB/WB 7 C/6 C - LWC 35 C (DT = 5 C) (nom. values according to EN14511) (2) cooling Ta 35 C - LWE 7 C (DT = 5 C); heating Ta DB/WB 7 C/6 C - LWC 45 C (DT = 5 C) (nom. values according to EN14511) 12

Daikin Altherma low temperature monobloc Heating & Cooling Single phase EBLQ11BC6V3 EBLQ14BC6V3 EBLQ16BC6V3 Heating capacity Nom. kw 11,2 1 / 8,11 2 14, 1 / 9,72 2 16, 1 / 1,69 2 Cooling capacity Nom. kw 12,85 1 / 1, 2 15,99 1 / 12,5 2 16,73 1 / 13,1 2 Power input Cooling Nom. kw 3,87 1 / 3,69 2 5,75 1 / 5,39 2 6,36 1 / 5,93 2 Heating Nom. kw 2,56 1 / 2,57 2 3,29 1 / 3,12 2 3,88 1 / 3,44 2 COP 4,38 1 / 3,16 2 4,25 1 / 3,12 2 4,12 1 / 3,11 2 EER 3,32 1 / 2,71 2 2,78 1 / 2,32 2 2,63 1 / 2,21 2 Dimensions Unit Height X Width X Depth mm 1.418 X 1.435 X 382 Weight Unit kg 18 Hydraulic component Back-up Type heater current Power supply Phase/Frequency/ ~/Hz/V Voltage 1~/5/23 Operation range Heating Ambient Min.~Max. C -2~35 Water side Min.~Max. C 15~55 Cooling Ambient Min.~Max. C 1~46 Water side Min.~Max. C 5~22 Domestic hot water Ambient Min.~Max. C -2~43 Water side Min.~Max. C 25~8 Refrigerant Type R-41A Charge kg 2,95 Sound power level Heating Nom. dba 64 65 66 Cooling Nom. dba 65 66 69 Sound pressure level Compressor component Heating Nom. dba 5 52 Cooling Nom. dba 5 52 54 Main power supply Name V3 Phase 1~ Frequency Hz 5 Voltage V 23 6V3 (1) cooling Ta 35 C - LWE 18 C (DT = 5 C); heating Ta DB/WB 7 C/6 C - LWC 35 C (DT = 5 C)(nom. values according to EN14511) (2) cooling Ta 35 C - LWE 7 C (DT = 5 C); heating Ta DB/WB 7 C/6 C - LWC 45 C (DT = 5 C) (nom. values according to EN14511) Heating & Cooling Three phase EBLQ11BC6W1 EBLQ14BC6W1 EBLQ16BC6W1 Heating capacity Nom. kw 11,2 1 / 8,11 2 14, 1 / 9,72 2 16, 1 / 1,69 2 Cooling capacity Nom. kw 12,85 1 / 1, 2 15,99 1 / 12,5 2 16,73 1 / 13,1 2 Power input Cooling Nom. kw 3,87 1 / 3,69 2 5,4 1 / 5,6 2 6,15 1 / 5,75 2 Heating Nom. kw 2,6 1 / 2,61 2 3,3 1 / 3,13 2 3,81 1 / 3,44 2 COP 4,31 1 / 3,11 2 4,24 1 / 3,11 2 4,2 1 / 3,11 2 EER 3,32 1 / 2,71 2 2,96 1 / 2,47 2 2,72 1 / 2,28 2 Dimensions Unit Height X Width X Depth mm 1.418 X 1.435 X 382 Weight Unit kg 18 Hydraulic Back-up Type 6W1 component heater current Power Phase/Frequency/ ~/Hz/V supply Voltage 3~/5/4 Operation range Heating Ambient Min.~Max. C -25~35 Water side Min.~Max. C 15~55 Cooling Ambient Min.~Max. C 1~46 Water side Min.~Max. C 5~22 Domestic hot water Ambient Min.~Max. C -25~43 Water side Min.~Max. C 25~8 Refrigerant Type R-41A Charge kg 2,95 Sound power level Heating Nom. dba 64 65 66 Cooling Nom. dba 65 66 69 Sound pressure level Compressor component Heating Nom. dba 49 51 53 Cooling Nom. dba 5 52 54 Main power supply Name W1 Phase 3N~ Frequency Hz 5 Voltage V 4 (1) cooling Ta 35 C - LWE 18 C (DT = 5 C); heating Ta DB/WB 7 C/6 C - LWC 35 C (DT = 5 C) (nom. values according to EN14511) (2) cooling Ta 35 C - LWE 7 C (DT = 5 C); heating Ta DB/WB 7 C/6 C - LWC 45 C (DT = 5 C) (nom. values according to EN14511) 13

Daikin Altherma low temperature monobloc Pricelist Daikin Altherma monobloc is designed as a compact unit, including refrigeration cycle and all necessary parts of the water cycle in the units casing. Daikin Altherma monobloc simply has to be connected to water pipings, without the need for refrigeration piping done by the installer. Beside hydraulic parts such as water pump, expansion vessel, safety valve, water filter and flow switch monobloc also includes a 6 kw factory mounted backup heater, which can be reduced during commissioning to a minimum of 2 kw (4V heater) or 3 kw (23V heater). Daikin Altherma low temperature monobloc heating only Inverter monobloc heat pump with nominal capacities from 11 to 16 kw. Nominal capacity is measured at A7/W35. Daikin Altherma 11kW Monobloc 23V EDLQ11BC6V3 6kW BUH, Power Supply 1~ 23V 6.735,- Daikin Altherma 14kW Monobloc 23V EDLQ14BC6V3 6kW BUH, Power Supply 1~ 23V 7.397,- Daikin Altherma 14kW Monobloc 23V EDLQ16BC6V3 6kW BUH, Power Supply 1~ 23V 7.947,- Daikin Altherma 11kW Monobloc 4V EDLQ11BC6W1 6kW BUH, Power Supply 3~ 4V 7.331,- Daikin Altherma 14kW Monobloc 4V EDLQ14BC6W1 6kW BUH, Power Supply 3~ 4V 8.36,- Daikin Altherma 14kW Monobloc 4V EDLQ16BC6W1 6kW BUH, Power Supply 3~ 4V 8.679,- Daikin Altherma low temperature monobloc heating & cooling Inverter monobloc heat pump with nominal capacities from 11 to 16 kw. Nominal capacity is measured at A7/W35. Daikin Altherma 11kW Monobloc 23V EBLQ11BC6V3 6kW BUH, Power Supply 1~ 23V 7.23,- Daikin Altherma 14kW Monobloc 23V EBLQ14BC6V3 6kW BUH, Power Supply 1~ 23V 7.684,- Daikin Altherma 14kW Monobloc 23V EBLQ16BC6V3 6kW BUH, Power Supply 1~ 23V 8.235,- Daikin Altherma 11kW Monobloc 4V EBLQ11BC6W1 6kW BUH, Power Supply 3~ 4V 7.618,- Daikin Altherma 14kW Monobloc 4V EBLQ14BC6W1 6kW BUH, Power Supply 3~ 4V 8.323,- Daikin Altherma 14kW Monobloc 4V EBLQ16BC6W1 6kW BUH, Power Supply 3~ 4V 8.968,- 14

Daikin Altherma low temperature monobloc Options & accessories Applicable for: 11-16kW Wired room thermostat EKRTWA Wired Digital Room Thermostat 145,- Wireless room thermostat EKRTR Wireless Digital Room Thermostat 286,- Digital I/O PCB EKRP1HBA Remote alarm / operation status / 152,- Thermostat external sensor EKRTETS Temperature measurement remotely from wireless room thermostat (e.g. floor temperature) 17,- Solar Kit EKSOLHW Heat exchanger to connect Daikin solar system to EKHWS and EKHWE DHW tank 851,- Domestic hot water connection kit for EKDVCPLT5H Connection kit for EDLQ heating only models EKHWP5B H/O in combination with EKHWP5B 554,- Domestic hot water connection kit for EKDVCPLT5X Connection kit for EBLQ heating & cooling models EKHWP5B H/C in combination with EKHWP5B 735,- Electrical Booster Heater EKBH3S Electrical booster heat for EKHWP-B tanks 361,- Domestic hot water tanks (can be used for solar option) Applicable for: 11-16kW Stainless Steel Domestic Hot Water Tank 15L EKHWS15B3V3 incl. 3kW booster heater 1~ 23V, height 9mm, diameter 58mm, weight 37kg 1.5,- Wallbracket for 15L stainless steel tank EKWBSWW15 32,- Stainless Steel Domestic Hot Water Tank 2L EKHWS2B3V3 incl. 3kW booster heater 1~ 23V, height 115mm, diameter 58mm, weight 45kg 1.84,- Stainless Steel Domestic Hot Water Tank 2L EKHWS2B3Z2 incl. 3kW booster heater 2~ 4V, height 115mm, diameter 58mm, weight 45kg 1.84,- Stainless Steel Domestic Hot Water Tank 3L EKHWS3B3V3 incl. 3kW booster heater 1~ 23V, height 16mm, diameter 58mm, weight 59kg 1.225,- Stainless Steel Domestic Hot Water Tank 3L EKHWS3B3Z2 incl. 3kW booster heater 2~ 4V, height 16mm, diameter 58mm, weight 59kg 1.225,- Enameled Domestic Hot Water Tank 15L EKHWE15A3V3 incl. 3kW booster heater 1~ 23V, height 125mm, diameter 545mm, weight 8kg 875,- Enameled Domestic Hot Water Tank 15L (wallmounted) EKHWET15A3V3 incl. 3kW booster heater 1~ 23V, height 125mm, diameter 545mm, weight 82kg not relevant Enameled Domestic Hot Water Tank 2L EKHWE2A3V3 incl. 3kW booster heater 1~ 23V, height 158mm, diameter 545mm, weight 14kg 92,- Enameled Domestic Hot Water Tank 2L EKHWE2A3Z2 incl. 3kW booster heater 2~ 4V, height 158mm, diameter 545mm, weight 14kg 92,- Enameled Domestic Hot Water Tank 3L EKHWE3A3V3 incl. 3kW booster heater 1~ 23V, height 1572mm, diameter 66mm, weight 14kg 1.2,- Enameled Domestic Hot Water Tank 3L EKHWE3A3Z2 incl. 3kW booster heater 2~ 4V, height 1572mm, diameter 66mm, weight 14kg 1.2,- Pressureless 5L Domestic Hot Water Tank EKHWP5B Pressureless hygienic domestic hot water tank with solar option 2.211,- 15

Daikin Altherma high temperature For replacement of traditional boilers Daikin Altherma high temperature system offers heating and domestic hot water for your home. This system can perfectly replace a traditional boiler and connect to the existing piping. Daikin Altherma high temperature is therefore the ideal solution for renovations. The split system consists of an outdoor unit and an indoor unit and can be completed with solar connection. Solar connection (optional) Domestic hot water tank Outdoor unit Indoor unit 16

Split system A split system consists of an outdoor unit and an indoor unit The Daikin Altherma outdoor unit includes a heat pump that extracts heat from the outside air resulting in nearly 2/3 of all usable heat coming from a sustainable and free source. The outdoor unit extracts heat from the ambient outdoor air. This heat is transferred to the indoor unit via refrigerant piping. The indoor unit receives the heat from the outdoor unit and further increases the temperature, allowing water temperatures up to 8 C for heating through radiators and for domestic hot water use. Daikin s unique cascade compressor approach to the heat pumps (one in the outdoor unit/one in the indoor unit) means optimum comfort at even the coldest outdoor temperatures, without the need for an electric back-up heater. Daikin Altherma high temperature heats up to 3 times more efficiently than a traditional heating system based on fossil fuels or electricity. A lower running cost is thus achieved, while you can still enjoy a stable and pleasant level of comfort.* * COP (Coefficient of Performance) of up to 3.8 Domestic hot water tank Daikin Altherma s high water temperature is ideal for heating domestic hot water without the need for an additional electric heater. Rapid heating of domestic hot water also means smaller heaters are needed. For a family of approximately 4 people, the standard tank is the best solution. Should you require more hot water, a larger tank is also available. Heat emitters The Daikin Atherma high temperature system is designed to work with high-temperature radiators, which come in various sizes and formats to suit the interior design as well as the heating requirement. The radiators can be individually controlled or they can be regulated by the central heating control programme. Solar connection The Daikin Altherma high temperature heating system can optionally use solar energy for hot water production. If the solar energy is not required immediately, the purposebuilt hot water tank (EKHWP) can store large quantities of heated water for up to a day for later use as domestic hot water or for heating. 17

Daikin Altherma high temperature Technical specifications OUTDOOR UNIT ERRQ11AV1 ERRQ14AV1 ERRQ16AV1 ERRQ11AY1 ERRQ14AY1 ERRQ16AY1 Heating capacity Nom. kw 11 1 / 11 2 14 1 / 14 2 16 1 / 16 2 11 1 / 11 2 14 1 / 14 2 16 1 / 16 2 Power input Heating Nom. kw 3,57 1 / 4,4 2 4,66 1 / 5,65 2 5,57 1 / 6,65 2 3,57 1 / 4,4 2 4,66 1 / 5,65 2 5,57 1 / 6,65 2 COP 3,8 1 / 2,5 2 3, 1 / 2,48 2 2,88 1 / 2,41 2 3,8 1 / 2,5 2 3, 1 / 2,48 2 2,88 1 / 2,41 2 Dimensions Unit H x W x D mm 1.345x9x32 Weight Unit kg 12 Operation range Heating Min.~Max. CWB -2~2 Domestic hot water Min.~Max. CDB -2~35 Refrigerant Type R-41A Charge kg 4,5 Sound power level Heating Nom. dba 68 69 71 68 69 71 Sound pressure level Heating Nom. dba 52 53 55 52 53 55 Power supply Name/Phase/Frequency/Voltage Hz/V 1~/5/22-44 3~/5/38-415 Current Recommended fuses A 25 16 (1) EW 55ºC; LW 65ºC; Dt 1ºC; ambient conditions: 7ºCDB/6ºCWB (2) EW 7ºC; LW 8ºC; Dt 1ºC; ambient conditions: 7ºCDB/6ºCWB INDOOR UNIT - floor standing EKHBRD11ACV1 EKHBRD14ACV1 EKHBRD16ACV1 EKHBRD11ACY1 EKHBRD14ACY1 EKHBRD16ACY1 Casing Colour Metallic grey Material Precoated sheet metal Dimensions Unit H x W x D mm 75x6x695 Weight Unit kg 144,25 147,25 Operation range Heating Ambient Min.~Max. C -2~2 Water side Min.~Max. C 25~8 Domestic hot water Ambient Min.~Max. CDB -2~35 Water side Min.~Max. C 25~8 Refrigerant Type R-134a Charge kg 3,2 Sound pressure level Nom. dba 43 / 46 45 / 46 46 / 46 43 / 46 45 / 46 46 / 46 43 / 46 45 / 46 46 / 46 43 / 46 45 / 46 46 / 46 Night quiet mode Level 1 dba 4 43 45 4 43 45 4 43 45 4 43 45 Power supply Name V1 Y1 Phase 1~ 3~ Frequency Hz 5 Voltage V 22-24 38-415 Current Recommended fuses A 25 16 18

Daikin Altherma high temperature Solar collector EKSH26P EKSV21P EKSV26P Dimensions Unit H x W x D mm 1.3x2.x85 2.x1.6x85 2.x1.3x85 Weight Unit kg 42 35 42 Volume l 2,1 1,3 1,7 Surface Outer m² 2,6 2,1 2,6 Aperture m² 2,35 1,79 2,35 Absorber m² 2,36 1,8 2,36 Coating Micro-therm (absorption max.96%, Emission ca. 5% +/-2%) Absorber Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate Glazing Single pane safety glass, transmission +/- 92% Allowed angle Min.~Max. 15~8 Operating pressure Max. bar 6 Stand still temperature Max. C 2 Thermal performance Zero loss collector efficiency η % - Solar controller EKSRPS3 Mounting On side of tank Dimensions Unit H x W x D mm 815x23x142 Thermal performance Zero loss collector efficiency η % - Control Type Digital temperature difference controller with plain text display Power consumption W 2 Sensor Solar panel temperature sensor Pt1 Storage tank sensor PTC Return flow sensor PTC Feed temperature and flow sensor Voltage signal (3,5V DC) Power supply Voltage V 23 Domestic hot water tank EKHTS2AC EKHTS26AC Casing Colour Metallic grey Material Galvanised steel (precoated sheet metal) Dimensions Unit H x W x D mm 2.1x6x695 2.285x6x695 Weight Unit Empty kg 7 78 Tank Water volume l 2 26 Material Stainless steel (EN 1.4521) Maximum water temperature C 75 Insulation Heat loss kwh/24h 1,2 1,5 Heat exchanger Quantity 1 Tube material Duplex steel (EN 1.4162) Face area m² 1,56 Internal coil volume l 7,5 Domestic hot water tank EKHWP3B EKHWP5B Dimensions Unit Height mm 1.64 1.64 Width mm 595 79 Depth mm 615 79 Weight Unit Empty kg 59 93 Tank Water volume l 3 5 Maximum water temperature C 85 Insulation Heat loss kwh/24h 1,3 1,4 Heat exchanger Domestic hot Tube material Stainless steel water Face area m² 5,8 6 Internal coil volume l 27,9 29 Operating pressure bar 6 Average specifc thermal output W/K 2.79 2.9 Charging Tube material Stainless steel Face area m² 2,7 3,8 Internal coil volume l 13,2 18,5 Operating pressure bar 3 Average specifc thermal output W/K 1.3 1.8 Auxiliary solar heating Tube material Stainless steel Face area m² -,5 Internal coil volume l - 2,3 Operating pressure bar 3 Average specifc thermal output W/K - 28 19

Pricelist Daikin Altherma high temperature Daikin Altherma cascade technology Daikin Altherma HT represents the most innovative solution for refurbishment projects. Equipped with a double inverter cascade system, it can produce leaving water temperatures up to 8 C, reached purely on thermodynamic principles without an additional direct electrical heater. Change a boiler directly to Daikin Altherma HT - your radiators can stay, no additional investments are necessary. High performance in 3 steps: 1 The outdoor unit extracts heat from the ambient outdoor air. This heat is transferred to the indoor unit via R-41A refrigerant. Daikin Altherma high temperature outdoor units Inverter Split Heat pump System with nominal capacities from 11 to 16 kw. Nominal capacity is measured at A7/W65, delta T 5K. Can only be combined with an indoor unit of the same capacity class and power supply. Daikin Altherma HT 11kW outdoor unit ERRQ11AV1 Power Supply 1~ 23V 3.19,- Daikin Altherma HT 14kW outdoor unit ERRQ14AV1 Power Supply 1~ 23V 3.716,- Daikin Altherma HT 16kW outdoor unit ERRQ16AV1 Power Supply 1~ 23V 4.22,- Daikin Altherma HT 11kW outdoor unit ERRQ11AY1 Power Supply 3~4V 3.562,- Daikin Altherma HT 14kW outdoor unit ERRQ14AY1 Power Supply 3~4V 4.29,- Daikin Altherma HT 16kW outdoor unit ERRQ16AY1 Power Supply 3~4V 4.797,- Daikin Altherma high temperature indoor units (floorstanding) for heating only applications. All basic necessary hydraulic components included. Domestic Hot water tank can be mounted on top of or next to the indoor unit as an option. Can only be combined with an outdoor unit of the same capacity class and power supply. Daikin Altherma HT 11kW indoor unit EKHBRD11ACV1 Floorstanding unit, power supply 1~ 23V 4.951,- Daikin Altherma HT 14kW indoor unit EKHBRD14ACV1 Floorstanding unit, power supply 1~ 23V 5.141,- Daikin Altherma HT 16kW indoor unit EKHBRD16ACV1 Floorstanding unit, power supply 1~ 23V 5.31,- Daikin Altherma HT 11kW indoor unit EKHBRD11ACY1 Floorstanding unit, power supply 3~ 4V 5.92,- Daikin Altherma HT 14kW indoor unit EKHBRD14ACY1 Floorstanding unit, power supply 3~ 4V 5.295,- Daikin Altherma HT 16kW indoor unit EKHBRD16ACY1 Floorstanding unit, power supply 3~ 4V 5.477,- Combinations OUTDOOR UNIT 23V 4V INDOOR UNIT EKHBRD11ACV1 EKHBRD14ACV1 EKHBRD16ACV1 EKHBRD11ACY1 EKHBRD14ACY1 EKHBRD16ACY1 23V 4V ERRQ11AV1 - ERRQ14AV1 ERRQ16AV1 ERRQ11AY1 ERRQ14AY1 ERRQ16AY1 2

Daikin Altherma high temperature Outdoor Indoor Step 1 Step 2 Step3 2 The 3 indoor unit receives the heat and further increases the temperature with R-134a refrigerant. The heat is transferred from the R-134a refrigerant circuit to the water circuit. Thanks to the unique cascade compressor approach, water temperatures of 8 C can be reached without using an additional back-up heater. Options & accessories Applicable for: 11-16kW Wired room thermostat EKRTWA Wired Digital Room Thermostat 145,- Wireless room thermostat EKRTR Wireless Digital Room Thermostat 286,- Digital I/O PCB EKRP1HBA Remote alarm / operation status / 152,- Modbus PCD RTD-W Monitoring and control ModBus interface 364,- Sequencing Controller EKCC-W Master/slave control kit that can control and monitor up to 16 hydroboxes, connected through RTD-W 1.237,- Thermostat external sensor EKRTETS Temperature measurement remotely from wireless room thermostat (e.g. floor temperature) 17,- Demand PCB for connection of room thermostat or backup heater EKRP1AHT Required when EKRTWA or EKRTR is used as a room thermostat or if a backup heater is installed 151,- Remote user interface EKRUAHTB Can be used as a second user interface (master/slave) besides the one delivered with the indoor unit 226,- In-line backup heater 1~, 23V, 6kW EKBUHA6V3 Electrical backup heater for space heating support only 67,- In-line backup heater 3~, 4V, 6kW EKBUHA6W1 Electrical backup heater for space heating support only 67,- Option kit for standalone tank EKFMAHTB Kit required when EKHTS tanks are to be placed next to the indoor unit 557,- Domestic hot water connection kit for EKHWP3B Domestic hot water connection kit for EKHWP5B EKEPHT3H EKEPHT5H Connection kit for HT in combination with EKHWP3B Connection kit for HT in combination with EKHWP5B 289,- 456,- Domestic hot water tanks Stainless steel domestic hot water tank 2L Stainless steel domestic hot water tank 26L EKHTS2AC EKHTS26AC Applicable for: 11-16kW Domestic hot water tank 2L, Dimensions HxBxT = 1.335x6x695, height increases to 2.1 mm if mounted on top of indoor unit 1.436,- Domestic hot water tank 26L, Dimensions HxBxT = 1.61x6x695, height increases to 2.285 mm if mounted on top of indoor unit 1.621,- Pressureless 3L domestic hot water tank EKHWP3B Pressureless hygienic domestic hot water tank with solar option 2.234,- Pressureless 5L domestic hot water tank EKHWP5B Pressureless hygienic domestic hot water tank with solar option 2.211,- 21

Daikin Altherma hybrid heat pump NEW! For replacement of a gas boiler A unique opportunity in residential heating! There is a growing demand from home owners to replace heating systems, especially replacing of gas boilers, with more efficient, more cost-effective and more environmentally friendly systems that reduce CO 2 emissions, reduce energy consumption and protect their budget. Hybrid technology The answer is the Daikin Altherma hybrid heat pump. For space heating, the Daikin Altherma hybrid heat pump will combine air-to-water heat pump technology with gas condensing technology by searching for the optimum economical condition for its operation, combining parameters of energy costs (electricity, gas), heat pump efficiency and heat load requirements to deliver up to 35% more heating efficiency, plus major cost savings. For domestic hot water, the Daikin Altherma hybrid heat pump optimises the operation of the most efficient gas condensing boiler. Your benefits 99 Low running costs for heating and domestic hot water compared to traditional boilers 99 Low investment cost 99 Provides sufficient heat in renovation applications 99 Easy and fast installation 22

Daikin Altherma hybrid heat pump NEW! Looking at an average European climate, the largest part of the required heat output is covered by the hybrid and heat pump operation, resulting in up to 35% more heating efficiency. Illustration of an average European climate Required heat output kwh/ C 18 Gas operation Hybrid operation Heat pump operation 16 14 12 1 8 6 4 2-7 15 Ambient temperature C + 35% efficiency (space heating) compared to condensing boiler Heat load: 14 kw 7% heat pump output 3% gas boiler output Heat load = the capacity of the space heating system required to maintain comfortable indoor temperatures at any time. Required heat output = heat load x n of occuring hours per year Heat pump operation The heat pump integrated in the Daikin Altherma hybrid heat pump is the best available technology for optimizing running costs at moderate outdoor temperatures, resulting in a coefficient of performance of 5,4 1! (1) heating Ta DB/WB 7 C/6 C - LWC 35 C (DT = 5 C) Hybrid operation If a high heat load is required, or to achieve the highest efficiencies at the current conditions, both the gas boiler and heat pump operate at the same time in the most economical way. The water flow rate will be automatically regulated, in order to have the possibility of lowering the temperature of the water flowing from the radiators to the heat pump and so maximizing heat pump efficiency. The exact time the switch-over is made from heat pump operation to hybrid operation depends on the house characteristics, energy prices and the requested indoor temperature setting. Gas operation When outdoor temperatures are dropping drastically, it is no longer efficient to operate in hybrid mode. At that point, the unit will switch automatically to gas operation only. 23

Daikin Altherma hybrid heat pump NEW! Technical specifications Heating only INDOOR UNIT EHYHBH5AV3 EHYHBH8AV3 EHYKOMB33AA Casing Colour White White - RAL91 Material Precoated sheet metal Dimensions Unit H x W x D mm 92x45x164 71x45x24 Weight Unit kg 3 31,2 36 Operation range Heating Ambient Min.~Max. C -25~25 -~- Water side Min.~Max. C 25~55 15 (1)~8 (1) Domestic hot water Water side Min.~Max. C -~- 4~65 Power supply Name/Phase/Frequency/Voltage Hz/V V3 / 1~ / 5 / 23 - (1) DB/WB 7 C/6 C - LWC 35 C (DT=5 C), boiler bypassed OUTDOOR UNIT EVLQ5CV3 EVLQ8CV3 Heating capacity Min. kw 1,8 (1) / 1,8 (2) Nom. kw 4,4 (1) / 4,3 (2) / 3,27 (3) 7,4 (1) / 6,89 (2) / 5,8 (3) Max. kw 5,12 (1) / 4,9 (2) / 4,81 (3) 1,2 (1) / 9,53 (2) / 7,68 (3) Power input Heating Nom. kw,87 (1) / 1,13 (2) / 1,23 (3) 1,66 (1) / 2,1 (2) / 1,64 (3) COP 5,4 (1) / 3,58 (2) / 4,2 (3) 4,45 (1) / 3,42 (2) / 3,53 (3) Dimensions Unit H x W x D mm 735x832x37 Weight Unit kg 54 56 Operation range Heating Min.~Max. CWB -25~25 Refrigerant Type R-41A Charge kg 1,45 1,6 Sound power level Heating Nom. dba 61 62 Sound pressure level Heating Nom. dba 48 49 Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/5/23 Current Recommended fuses A 2 (1) Condition: Ta DB/WB 7 C/6 C - LWC 35 C (DT = 5 C); (2) Condition: Ta DB/WB 7 C/6 C - LWC 45 C (Dt=5 C); (3) Condition: Ta DB/WB 2 C/1 C - LWC 35 C (Dt=5 C) Heating & Cooling INDOOR UNIT EHYHBX8AV3 EHYKOMB33AA Casing Colour White White - RAL91 Material Precoated sheet metal Dimensions Unit H x W x D mm 92x45x164 71x45x24 Weight Unit kg 31,2 36 Operation range Heating Ambient Min.~Max. C -25~25 -~- Water side Min.~Max. C 25~55 15 (1)~8 (1) Cooling Ambient Min.~Max. C 1~43 - Water side Min.~Max. C 5~22 - Domestic hot water Water side Min.~Max. C -~- 4~65 Power supply Name V3 - Phase 1~ Frequency Hz 5 Voltage V 23 OUTDOOR UNIT EVLQ8CV3 Heating Min. kw 1,8 (1) / 1,8 (2) capacity Nom. kw 7,4 (1) / 6,89 (2) / 5,8 (3) Max. kw 1,2 (1) / 9,53 (2) / 7,68 (3) Cooling capacity Min. kw 2,5 (4) / 2,5 (5) Nom. kw 6,86 (4) / 5,36 (5) Power input Heating Nom. kw 1,66 (1) / 2,1 (2) / 1,64 (3) Cooling Nom. kw 2,1 (4) / 2,34 (5) COP 4,45 (1) / 3,42 (2) / 3,53 (3) EER 3,41 (4) / 2,29 (5) Dimensions Unit H x W x D mm 735x832x37 Weight Unit kg 56 Operation range Heating Min.~Max. CWB -25~25 Refrigerant Type R-41A Charge kg 1,6 Sound power level Heating Nom. dba 62 Sound pressure level Heating Nom. dba 49 (3) Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/5/23 Current Recommended fuses A 2 (1) Condition: Ta DB/WB 7 C/6 C - LWC 35 C (DT = 5 C); (2) Condition: Ta DB/WB 7 C/6 C - LWC 45 C (Dt=5 C); (3) Condition: Ta DB/WB 2 C/1 C - LWC 35 C (Dt=5 C) (4) Cooling: Ta 35 C - LWE 18 C (DT=5 C); (5) Cooling: Ta 35 C - LWE 7 C (DT=5 C) 24

Daikin Altherma hybrid heat pump NEW! Pricelist Daikin Altherma hybrid heat pump combines air-to-water heat pump technology with gas condensing technology by searching for the optimum economical condition for its operation, combining parameters of energy costs (electricity, gas), heat pump efficiency and heat load requirements to deliver up to 35% more heating efficiency, giving major cost savings. Please note that a complete hybrid system consists of one outdoor unit, one hydro module, one gas boiler module, one user interface and one cover plate. DAIKIN Altherma hybrid heat pump - outdoor units DAIKIN Altherma hybrid heat pump - hydro module (Controller needs to be ordered separately!) Daikin Altherma Hybrid indoor unit for 5kW EHYHBH5AV3 outdoor unit, heating only Daikin Altherma Hybrid indoor unit for 8kW EHYHBH8AV3 outdoor unit, heating only Daikin Altherma Hybrid indoor unit for 8kW EHYHBX8AV3 outdoor unit, heating & cooling power supply 1~ 23V, incl. high efficiency pump, expansion vessle, safety valve assembly, flow guard...etc. (W x D x H) 45 x 164 x 92 power supply 1~ 23V, incl. high efficiency pump, expansion vessle, safety valve assembly, flow guard...etc. (W x D x H) 45 x 164 x 92 power supply 1~ 23V, incl. high efficiency pump, expansion vessle, safety valve assembly, flow guard...etc. (W x D x H) 45 x 164 x 92 DAIKIN Altherma hybrid heat pump - gas condensing combi boiler* Daikin Altherma Hybrid Gas condensing combi boiler 7,9-31,9kW (8 C/6 C) EHYKOMB33AA gas condensing combi boiler with special 2 in 1 heat exchanger for space heating and instantaneous domestic hot water production, for natural and liquid gas, (W x D x H) 45 x 24 x 71 *The gas boiler module is standard equipped with a concentric flue gas connection diameter 6/1. *The gas boiler is certified for following flue gas systems : C13, C33, C43, C53, C63, C83 Daikin Altherma Hybrid Outodoor unit 5kW EVLQ5CV3 Power Supply 1~ 23V 1.618,- Daikin Altherma Hybrid Outodoor unit 8kW EVLQ8CV3 Power Supply 1~ 23V 2.99,- 1.22,- 1.233,- 1.382,- 2.58,- Necessary accessories for a complete installation (please only order one of the 7 controllers listed below) Applicable for: 5kW model 8kW model Remote Controller EKRUCBL1 User interface with languages FR, NL, DE, IT 143,- Remote Controller EKRUCBL2 User interface with languages EN, SV, FI, NO 143,- Remote Controller EKRUCBL3 User interface with languages EN, ES, PT, EL 143,- Remote Controller EKRUCBL4 User interface with languages EN, RO, PL, TR 143,- Remote Controller EKRUCBL5 User interface with languages DE, SI, CZ, SK 143,- Remote Controller EKRUCBL6 User interface with languages EN, HR, HU, BG 143,- Remote Controller EKRUCBL7 User interface with languages EN, DA, RU, LT 143,- Cover plate EKHY93467 Cover plate to hide the pipe connections underneath the unit 29,- Optional Accessories Propane Set EKHY75787 Kit for connection with liquid gas supply 13,- Valve kit EKVK1A Valves for space heating, domestic hot water an gas connection 15,- Mounting jig EKHYMNT1A Jig to help mount the indoor unit onto the wall 27,- Flue gas connector EKHY977 connection for 2x8 parallel connection (C53/C83) 2,- Double-walled connection set EKHY9717 Concentric connection set from DN 6/1 to DN 8/125 23,- U-beams for outdoor unit EKFT8CA Beams to mount outdoor unit on (height 25cm) 135,- PC cable EKPCCAB2 Cable to upload field settings from PC to unit 255,- Drain pan kit for indoor unit EKHYDP Collect and drain condensate during cooling operation 143,- Drainpan for outdoor unit (exl. drainpan heater) EKDP8C Collect water from defrost cycle and drain via central hole to remote location 168,- Heater tape for outdoor unit drainpan EKDPH8C Heater tape to install in central hole of drain pan to prevent ice blockage 255,- Pressureless 3L domestic hot water tank EKHWP3B pressureless hygienic domestic hot water tank with solar option 2.234,- Pressureless 5L domestic hot water tank EKHWP5B pressureless hygienic domestic hot water tank with solar option 2.211,- Domestic hot water connection kit EKEPHT3H connection kit for combination with EKHWP3B & EKHWP5B 289,- 25

Daikin Altherma hybrid heat pump NEW! Flue gas system for Daikin Altherma hybrid boiler For the combination with the Daikin Altherma hybrid gas condensing boiler, Daikin offers a robust white concentric PP-flue system. To safeguard an optimal operation of the system, Daikin advises to use this flue gas system in combination with it s Daikin Altherma hybrid heat pump system. The flue gas system is easy to set up in combination with the Daikin Altherma hybrid gas condensing boiler. In order to make the selection of you flue gas system easier for you, please visit http://fluegas.daikin.eu/ and use the Daikin flue gas selector tool. C33 TOP C43 C13 C43 C33 FLAT C93 C33S 26

Daikin Altherma hybrid heat pump NEW! C13, C33 concentric 6/1 Material name Description Price EKFGP6837 Roof Terminal PP/GLV 6/1 AR46 82,- C13, C33 Concentric 8/125 Material name Description Price EKFGP6864 Roof Terminal PP/GLV 8/125 AR3 Ral-911 97,- Flex PP Dn.1 in combination with C43 Material name Description Price EKFGP5497 Chimney Top PP 1 incl. Flue Pipe 19,- EKFGS518 Weather Slate Steep Pb/GLV 6/1 18-22 119,- EKFGT63 Weather Slate Steep Pb/GLV 8/125 18-22 121,- EKFGP6316 Adapter Flex-Fixed PP 1 5,- EKFGS519 Weather Slate Steep Pb/GLV 6/1 23-27 119,- EKFGT631 Weather Slate Steep Pb/GLV 8/125 23-27 124,- EKFGP6337 Support Breaket Top Inox Dn.1 23,- EKFGP791 Weather Slate Steep PF 6/1 25-45 48,- EKFGP799 Weather Slate Steep PF 8/125 25-45 Ral-911 5,- EKFGP6346 Extension Flex PP 1 L=1 M 269,- EKFGS523 Weather Slate Steep Pb/GLV 6/1 43-47 124,- EKFGT635 Weather Slate Steep Pb/GLV 8/125 43-47 133,- EKFGP6349 Extension Flex PP 1 L=15 M 45,- EKFGS524 Weather Slate Steep Pb/GLV 6/1 48-52 13,- EKFGT636 Weather Slate Steep Pb/GLV 8/125 48-52 135,- EKFGP6347 Extension Flex PP 1 L=25 M 666,- EKFGS525 Weather Slate Steep Pb/GLV 6/1 53-57 133,- EKFGT637 Weather Slate Steep Pb/GLV 8/125 53-57 145,- EKFGP6325 Connector Flex- Flex PP 1 45,- EKFGP1296 Weather Slate Flat Alu 6/1-15 73,- EKFGP1297 Weather Slate Flat Alu 8/125-15 8,- EKFGP694 Weather Slate Flat Alu 6/1 35,- EKFGW5333 Weather Slate Flat Alu 8/125 35,- EKFGP2978 Kit horizontal PP/GLV 6/1 53,- EKFGW6359 Wall Terminal Kit PP/ GLV 8/125 92,- EKFGP2977 Kit horizontal low profile PP/GLV 6/1 66,- EKFGP481 Extension PP/GLV 8/125 x 5mm 4,- EKFGP4651 Extension PP/GLV 6/1 x 5mm 35,- EKFGP482 Extension PP/GLV 8/125 x 1mm 43,- EKFGP4652 Extension PP/GLV 6/1 x 1mm 4,- EKFGP4814 Elbow PP/GLV 8/125 3 45,- EKFGP4664 Elbow PP/GLV 6/1 3 45,- EKFGP4811 Elbow PP/ALU 8/125 45 35,- EKFGP4661 Elbow PP/GLV 6/1 45 29,- EKFGP481 Elbow PP/ALU 8/125 9 35,- EKFGP466 Elbow PP/GLV 6/1 9 32,- EKFGP482 Inspection Elbow Plus PP/ ALU 8/125 9 EPDM 87,- EKFGP4667 Meas. Tee with Inspection Panel PP/GLV 6/1 111,- EKFGP4481 Fixation / Wall Bracket Dn.125 13,- EKFGP4631 Fixation / Wall Bracket Dn.1 1,- Flex PP Dn.6-8 C93/C33s Material name Description Price EKFGP1856 Flex Kit PP Dn.6-8 272,- Multi Flex PP Dn.1 & Dn.13 C43 6/1 ONLY Material name Description Price EKFGP6368 Tee Flex 1 Boiler Connectionset 1 26,- Flex PP Dn.13 in combination with C43 Material name Description Price EKFGP5197 Chimney Top PP 13 incl. Flue Pipe 158,- EKFGP4678 Chimney Connection 6/1 53,- EKFGP6354 Flex 1-6 + Support Elbow 15,- EKFGS252 Adapter Flex-Fixed PP 13 63,- EKFGP252 Flex Kit PP Dn.8 31,- EKFGP6215 Tee Flex 13 Boiler Connectionset 1 227,- EKFGP6353 Support Breaket Top Inox Dn.13 45,- EKFGP4828 Chimney Connection 8/125 53,- EKFGS257 Flex 13-6 + Support Elbow 168,- EKFGS25 Extension Flex PP 13 L=3 M 872,- EKFGP634 Extension Flex PP 8 L=1 M 221,- EKFGP4678 Chimney Connection 6/1 53,- EKFGP6366 Connector Flex- Flex PP 13 66,- EKFGP6344 Extension Flex PP 8 L=15 M 333,- EKFGP5461 Extension PP 6x5 1,- EKFGP6341 Extension Flex PP 8 L=25 M 511,- EKFGP6342 Extension Flex PP 8 L=5 M 951,- EKFGP6324 Connector Flex- Flex PP 8 4,- EKFGP6333 Spacer PP 8-1 13,- 27

Daikin Altherma ground source heat pump NEW! For new build and replacement of boilers A new opportunity for heating and domestic hot water. Geothermal energy is a free source of energy for heating, and domestic hot water. It delivers enormous cost savings in even the coldest climates as the energy is at a relatively constant temperature all year round. The compact design of the inside unit requires very little space whilst, at the same time, making the system very easy and quick to install. And, once commissioned, our easy, user-friendly controls put the user in complete command. Daikin Altherma ground source heat pump horizontal Daikin Altherma ground source heat pump vertical 28

Daikin Altherma ground source heat pump NEW! High seasonal efficiency thanks to our inverter heat pump technology The Daikin inverter heat pump technology has been shown to provide an increase in seasonal efficiency of up to 2% when compared to traditional on/off ground source heat pumps. The brine, a water/anti-freeze mixture that operates as heat transfer medium between the ground and the heat pump, is kept at a higher stable temperature Back up operation is reduced to a minimum High operating efficiencies of the compressor are reached at partial load operation, i.e. when no full capacity of the unit is required. This results in reduced running costs and a faster return on investment. Higher brine temperatures during continuous compressor operation, in partial load conditions Case study Typical application: Location: Sweden Design temperature: -17 C Heat load: 13kW Heating off temperature: 16 C 1 8 6 4 2-2 -4-6 -8 T ( C) Operation ON/OFF unit Partial load condition - ON/OFF OFF ON Outgoing Brine Temperature (HP as reference) OFF ON t 1 8 6 4 2-2 -4-6 -8 T ( C) Operation Daikin unit Partial load condition - Inverter controlled ON Outgoing Brine Temperature (HP as reference) t When no full capacity is required of the system the compressor works in partial load. In partial load conditions, a traditional on/off ground source heat pump sequently switches ON and OFF, whereby the brine temperature decreases down to -4 C when the unit is operating. Daikin s inverter technology results in a stable outgoing brine temperature of around C. This increased stability in brine temperature results in a higher and more constant evaporating temperature which leads to higher operating efficiencies. Less back up heater operation thanks to the boosting of the inverter compressor frequency Capacity (kw) Heat load line Traditional ON/OFF unit Daikin unit BUH* = Back-up heater BUH* Required heat output of your home Ambient temperature (Ta) C Compared to a traditional On/Off unit, the requirement for support from the back up heater is much lower for the Daikin Altherma ground source heat pump, thanks to the boosting effect of our inverter compressors, also this leads to lower running costs. 29

Daikin Altherma ground source heat pump NEW! Technical specifications Heating only INDOOR UNIT EGSQH1S18A9W Heating Min. kw 3,11 (1) / 2,47 (2) capacity Nom. kw 1,2 (1) / 9,29 (2) Max. kw 13, (1) / 11,9 (2) Power input Nom. kw 2,34 (1) / 2,82 (2) COP 4,35 (1) / 3,29 (2) Casing Colour White Material Precoated sheet metal Dimensions Unit HxWxD mm 1.732x6x728 Weight Unit kg 21 Tank Water volume l 18 Insulation Heat loss kwh/24h 1,36 Corrosion protection Anode Operation Installation Min.~Max. C 5~3 range space Brine side Min.~Max. C -5~2 Heating Water side Min.~Max. C 24~6 (heat pump) / 65 (heat pump + back up heater) Domestic hot water Water side Min.~Max. C 24~6 (heat pump) / 6 (back up heater) Refrigerant Type R-41A Charge kg 1,8 Sound power level Nom. dba 46 Sound pressure level Nom. dba 32 Power supply Name 9W Phase 3~ Frequency Hz 5 Voltage V 4 Current Recommended fuses A 32 (1) EWB/LWB C/-3 C - LWC 35 C (DT=5 C) (2) EWB/LWB C/-3 C - LWC 45 C (DT=5 C) 3

Daikin Altherma ground source heat pump NEW! Pricelist The Daikin Altherma ground source heat pump system features a compact indoor unit with a fully integrated inverter heat pump module and hot water tank. It needs to be combined with either a deep or shallow collector to draw energy from the ground. It is easy to use too, with smart room temperature controls and an energy usage display, helping to reduce energy consumption, while ensuring high levels of comfort. DAIKIN Altherma ground source heat pump Daikin Altherma ground source heat pump 1kW EGSQH1S18A9W Daikin Altherma ground source heat pump unit incl. 18L DHW tank 8.968,- Necessary accessories for a complete installation (please only order one of the 7 controllers listed below) Controller EKRUCBL1 User interface with languages FR, NL, DE, IT 143,- Controller EKRUCBL2 User interface with languages EN, SV, FI, NO 143,- Controller EKRUCBL3 User interface with languages EN, ES, PT, EL 143,- Controller EKRUCBL4 User interface with languages EN, RO, PL, TR 143,- Controller EKRUCBL5 User interface with languages DE, SI, CZ, SK 143,- Controller EKRUCBL6 User interface with languages EN, HR, HU, BG 143,- Controller EKRUCBL7 User interface with languages EN, DA, RU, LT 143,- Optional accessories Digital I/O PCB EKRP1HBA Remote alarm / operation status / 152,- Brine filling kit KGSFILL Kit to fil land flush the brine circuit 24,- Demand PCB EKRP1AHT Power consumption limitation with 4 digital inputs on hydrobox 151,- Remote indoor sensor KRCS1-1 Temperature measurement remotely from user interface 82,- PC cable EKPCCAB2 Cable to upload field settings from PC to unit 255,- Wired room thermostat EKRTWA Wired Digital Room Thermostat 145,- Wireless room thermostat EKRTR Wireless Digital Room Thermostat 286,- Thermostat external sensor EKRTETS Temperature measurement remotely from wireless room thermostat (e.g. floor temperature) 17,- 31

Daikin Altherma Flex Type Efficient climate control for residential applications Outdoor 1 2 Hot water Heating 3 Cooling 2 3 Outdoor unit One or more outdoor units + several indoor units >> a modular system Heating/Cooling 1 = + Indoor installation Indoor unit Domestic hot water tank Commercial applications Fit for purpose & Hot water on demand The challenges for a fitness center: Large exercise rooms with high levels of heat being generated requiring rigorous climate control throughout the space High on demand hot water usage in the changing rooms The solution: Daikin Altherma Flex Type with its modular and flexible approach. 32

Daikin Altherma Flex Type 3-in-1 system Daikin Altherma Flex Type heats, cools and produces domestic hot water: Heating: leaving water temperatures up to 8 C Cooling: leaving water temperatures down to 5 C Hot water: tank temperatures up to 75 C Thanks to the heat recovery function, the system can heat up the hot water tank up to 6 C with rejected heat from cooling operation. Energy efficient heat pump TECHNOLOGY Compared to an oil boiler, this results in: Up to 36% less running costs* Up to 71% reduction of CO 2 emissions* Up to 35% reduction in primary energy use* * Data calculated taking in account Belgian conditions: SCOP of 3, average energy prices 27-21, CO 2 emission factor for electricity production Modular system One or more inverter-controlled outdoor heat pump units can provide heating, cooling and hot water. Outdoor units between 23 and 45 kw extract the heat from the outdoor air, raise it to an intermediate temperature and transfer this heat energy to the individual indoor units. Indoor units are available in several classes (6, 9, 11,14 and 16 kw), ensuring optimum efficiency. One outdoor unit can be combined with up to ten indoor units. Multiple outdoor units can be installed for larger applications. 1 Commercial space / 1 Apartment Total building 6kW 9kW 11kW 14kW 16kW 5kW 8kW 22kW 2kW 45kW 4kW Install separate outdoor units to reach higher capacities (Separate system: the outdoor units are not connected to each other) 1P, 23V 3P, 4V Note: Heating capacities 7 C ambient temperature, cooling capacities 35 C ambient temperature 33

Daikin Altherma Flex Type Technical specifications OUTDOOR UNIT EMRQ8A EMRQ1A EMRQ12A EMRQ14A EMRQ16A Heating capacity Nom. kw 22,4 28 33,6 39,2 44,8 Cooling capacity Nom. kw 2 25 3 35 4 Dimensions Unit HxWxD mm 1.68x1.3x765 Weight Unit kg 331 339 Operation range Heating Min.~Max. CWB -15~2 Domestic hot water Ambient Min.~Max. CDB -15~35 Cooling Min.~Max. CDB 1~43 Refrigerant Type R-41A Piping connections Liquid OD mm 9,52 12,7 Suction OD mm 19,1 22,2 28,6 High and low pressure gas OD mm 15,9 19,1 22,2 Piping length OU - IU Max. m 1 System Equivalent m 12 Total piping length System Actual m 3 Sound power level Heating Nom. dba 78 8 83 84 Sound pressure level Heating Nom. dba 58 6 62 63 Power supply Phase/Voltage V 3~/38-415 Heating conditions: Ta = 7 CDB / 6 CWB, 1% connection ratio Cooling conditions: Ta = 35 CDB, 1% connection ratio * Capacity not guaranteed between -2 C and -15 C 34

Daikin Altherma Flex Type INDOOR UNIT EKHVMRD5A EKHVMRD8A EKHVMYD5A EKHVMYD8A Casing Colour Metallic grey Material Precoated sheet metal Dimensions Unit HxWxD mm 75x6x695 Weight Unit kg 92 12 Operation range Heating Ambient Min.~Max. C -15~2 Water side Min.~Max. C 25~8 Cooling Ambient Min.~Max. CDB -~- 1~43 Water side Min.~Max. C -~- 5~2 Domestic hot water Ambient Min.~Max. CDB -15~35 Water side Min.~Max. C 45~75 Refrigerant Type R-134a Charge kg 2 Sound pressure level Nom. dba 4 1 / 43 2 42 1 / 43 2 4 1 / 43 2 42 1 / 43 2 Night quiet mode Level 1 dba 38 1 Power supply Name V1 Phase 1~ Frequency Hz 5 Voltage V 22-24 Current Recommended fuses A 2 INDOOR UNIT EKHBRD11ACV1 EKHBRD14ACV1 EKHBRD16ACV1 EKHBRD11ACY1 EKHBRD14ACY1 EKHBRD16ACY1 Casing Colour Metallic grey Material Precoated sheet metal Dimensions Unit HxWxD mm 75x6x695 Weight Unit kg 144,25 147,25 Operation range Heating Ambient Min.~Max. C -2~2 Water side Min.~Max. C 25~8 Cooling Ambient Min.~Max. CDB -~- Water side Min.~Max. C -~- Domestic hot water Ambient Min.~Max. CDB -2~35 Water side Min.~Max. C 25~8 Refrigerant Type R-134a Charge kg 3,2 Sound pressure level Nom. dba 43 1 / 46 2 45 1 / 46 2 46 1 / 46 2 43 1 / 46 2 45 1 / 46 2 46 1 / 46 2 Night quiet mode Level 1 dba 4 1 43 1 45 1 4 1 43 1 45 1 Power supply Name V1 Y1 Phase 1~ 3~ Frequency Hz 5 Voltage V 22-24 38-415 Current Recommended fuses A 25 16 (1) Sound levels are measured at: EW 55 C; LW 65 C (2) Sound levels are measured at: EW 7 C; LW 8 C 35

Daikin Altherma Flex Type Pricelist Daikin Altherma Flex Type for residential and commercial applications is a 3-in-1 system offering heating, domestic hot water and cooling all-in-one highly efficient. Daikin Altherma Flex Type achieves a typical seasonal COP of 3 in the moderate Western and central European climate. Further more, Daikin Altherma Flex Type is a modular system. Depending from your project one or more outdoor units can be combined with up to ten indoor units per outdoor unit. Daikin Altherma Flex Type outdoor units. Nominal heating capacity is measured at Ta 7 C and nominal cooling capacity at Ta 35 C with a 1% connection ratio. Daikin Altherma Flex outdoor unit 8HP EMRQ8A Outdoor unit with 22,4kW heating and 2kW cooling capacity, power suppy 3~ 4V Daikin Altherma Flex outdoor unit 1HP EMRQ1A Outdoor unit with 28 kw heating and 25kW cooling capacity, power suppy 3~ 4V Daikin Altherma Flex outdoor unit 12HP EMRQ12A Outdoor unit with 33,6kW heating and 3kW cooling capacity, power suppy 3~ 4V Daikin Altherma Flex outdoor unit 14HP EMRQ14A Outdoor unit with 39,2kW heating and 35kW cooling capacity, power suppy 3~ 4V Daikin Altherma Flex outdoor unit 16HP EMRQ16A Outdoor unit with 44,8kW heating and 4kW cooling capacity, power suppy 3~ 4V 1.932,- 11.587,- 12.68,- 15.34,- 17.49,- Daikin Altherma Flex Type indoor units (floorstanding) for heating& cooling and heating only applications. All basic necessary hydraulic components included. Daikin Altherma Flex 5kW indoor unit EKHVMRD5A Power Supply 1~ 23V 4.556,- heating only Daikin Altherma Flex 5kW indoor unit EKHVMYD5A Power Supply 1~ 23V 5.53,- heating & cooling Daikin Altherma Flex 8kW indoor unit EKHVMRD8A Power Supply 1~ 23V 4.75,- heating Daikin Altherma Flex 8kW indoor unit EKHVMYD8A Power Supply 1~ 23V 5.199,- heating & cooling Daikin Altherma Flex 11kW indoor unit EKHBRD11ACV1 Power Supply 1~ 23V 4.951,- heating only Daikin Altherma Flex 14kW indoor unit EKHBRD14ACV1 Power Supply 1~ 23V 5.141,- heating only Daikin Altherma Flex 16kW indoor unit EKHBRD16ACV1 Power Supply 1~ 23V 5.31,- heating only Daikin Altherma Flex 11kW indoor unit EKHBRD11ACY1 Power Supply 3~4V 5.92,- heating only Daikin Altherma Flex 14kW indoor unit EKHBRD14ACY1 Power Supply 3~4V 5.295,- heating only Daikin Altherma Flex 16kW indoor unit heating only EKHBRD16ACY1 Power Supply 3~4V 5.477,- 36

Daikin Altherma Flex Type Options & accessories Applicable for: 11-16kW Wired room thermostat EKRTWA Wired Digital Room Thermostat 145,- Wireless room thermostat EKRTR Wireless Digital Room Thermostat 286,- Digital I/O PCB EKRP1HBA Remote alarm / operation status 152,- Modbus Interface RTD-W monitoring and control ModBus interface 364,- Sequencing Controller EKCC-W master/slave control kit that can control and monitor up to 16 hydroboxes, connected through RTD-W 1.237,- Thermostat external sensor EKRTETS Temperature measurement remotely from wireless room thermostat (e.g. floor temperature) 17,- Demand PCB for connection of room thermostat or backup heater EKRP1AHT required when EKRTWA or EKRTR is used as a room thermostat or if a backup heater is installed 151,- Remote user interface EKRUAHTB can be used as a second user interface (master/slave) besides the one delivered with the indoor unit 226,- In-line backup heater 1~, 23V, 6kW EKBUHA6V3 Electrical backup heater for space heating support only 67,- In-line backup heater 3~, 4V, 6kW EKBUHA6W1 Electrical backup heater for space heating support only 67,- Option kit for standalone tank EKFMAHTB Kit required when EKHTS tanks are to be placed next to the indoor unit 557,- Optionional billing kit EKMBIL1 Option kit for billing of tank mounted on indoor unit 159,- Central drainpan kit for outdoor unit KWC25C45 drain pan kit to collect the condensate after defrost operation 1.347,- Domestic hot water connection kit for EKHWP3B Domestic hot water connection kit for EKHWP5B EKEPHT3H EKEPHT5H connection kit for HT in combination with EKHWP3B connection kit for HT in combination with EKHWP5B 289,- 456,- Domestic hot water tanks Stainless steel domestic hot water tank 2L Stainless steel domestic hot water tank 26L EKHTS2AC EKHTS26AC Applicable for: 11-16kW Domestic hot water tank 2L, Dimensions HxBxT = 1335x6x695, height increases to 21 if mounted on top of indoor unit 1.436,- Domestic hot water tank 2L, Dimensions HxBxT = 161x6x695, height increases to 2285 if mounted on top of indoor unit 1.621,- Pressureless 3L domestic hot water tank EKHWP3B pressureless hygienic domestic hot water tank with solar option 2.234,- Pressureless 5L domestic hot water tank EKHWP5B pressureless hygienic domestic hot water tank with solar option 2.211,- Refrigerant branch kits for outdoor units 3 pipes 3 pipes Outdoor unit capacity type (HP) imperial metric imperial metric 8 + 1 KHRQ23M29T9 KHRQM23M29T KHRQ22M29T9 KHRQM22M29T Price 149,- 149,- 135,- 135,- 12 ~ 16 KHRQ23M64T KHRQM23M64T KHRQ22M64T KHRQM22M64T Price 243,- 243,- 163,- 163,- Refnet joints for indoor units 3 pipes 3 pipes Indoor unit capacity index imperial metric imperial metric < 2 KHRQ23M2T KHRQM23M2T KHRQ22M2T KHRQM22M2T Price 129,- 129,- 1,- 1,- 2 x < 29 KHRQ23M29T9 KHRQM23M29T KHRQ22M29T9 KHRQM22M29T Price 149,- 149,- 135,- 135,- 29 x < 52 KHRQ23M64T KHRQM23M64T KHRQ22M64T KHRQM22M64T Price 243,- 243,- 163,- 163,- Refnet headers for indoor units 3 pipes 3 pipes Indoor unit capacity index imperial metric imperial metric <2 and 2 x < 29 KHRQ23M29H KHRQM23M29H KHRQ22M29H KHRQM22M29H Price 264,- 264,- 188,- 188,- 29 x < 52 KHRQ23M64H KHRQM23M64H KHRQ22M64H KHRQM22M64H Price 321,- 321,- 233,- 233,- 37

Heat pump convector Heat pump convector The heat pump convector unit can provide both heating and cooling if required, since the heat pump convector is more than just a fan coil unit. The heat pump convector also has a very low noise level. When combining under floor heating and fan coil units, the low leaving water temperatures, important for efficiency, are adequate for under floor heating, but the fan coil units then need to be oversized in order to emit the proper levels of heat at these low water temperatures. The heat pump convector solves this problem. The heat pump convector is able to emit the required levels of heat at low leaving water temperatures, while retaining a modest size. Instead of the leaving water circuit being switched on and off via a thermostat in a single master room, each heat pump convector can be directly wired to the Daikin Altherma indoor unit, the system s intelligence centre. This allows all rooms to have heat when required, regardless of the state of the other rooms. The heat pump convector saves on running costs thanks to the improved efficiency by approximately 25% compared to a heating system that combines underfloor heating and regular fan coil units. The heat pump convector can easily replace existing heat emitters, thanks to its plug and play installation. 38

Heat pump convector Technical specifications INDOOR UNITS FWXV2A FWXV15A Heating capacity Total capacity Nom. kw 2, 1,5 Cooling capacity Total capacity Nom. kw 1,7 1,2 Sensible Nom. kw 1,4,98 capacity Power input Heating Nom. kw,15,13 Cooling Nom. kw,15,13 Dimensions Unit H x W x D mm 6/7/21 Weight Unit kg 15 Piping connections Drain/OD/Inlet/Outlet mm/ inch 18/G 1/2/G 1/2 Sound pressure level Heating Nom. dba 29 19 Cooling Nom. dba 29 19 Power supply Phase/Frequency/Voltage Hz/V 1~/5/6/22-24/22 (1) Cooling: indoor temp. 27 CDB, 19 CWB; entering water temp. 7 C, water temperature rise 5K. (2) Heating: room temperature 2 CDB and entering water temperature 45 C, water temperature drop 5K. Pricelist Daikin s Heat pump convector with interlink function is another heating innovation coming from the Daikin internal product development. Perfectly suitable for low temperature applications, e.g. in combination with underfloor heating, the Heat pump convector is a stylish, compact, intelligent and very silent solution for quick heating or cooling of residential areas. Daikin Altherma Heat pump Convector Daikin Altherma FWXV15A Heat pump convector with 1,5kW* heating capacity Heat pump Convector 1,5kW and 1,2kW** and,3kw*** cooling capacity 677,- Daikin Altherma FWXV2A Heat pump convector with 2,kW* heating capacity Heat pump Convector 2,kW and 1,7kW** and,4kw*** cooling capacity 73,- Options & Accessories 2 way valve kit EKVKHPC needs to be used in all cooling and high temperature applications, where watertemperatures of below 18 C and/or 6 C or above can occur 97,- * water inlet temperature 45 C and water outlet temperature 4 C, room temperature 2 C DB - medium fanspeed **water inlet temperature 7 C and water outlet temperature 12 C, room temperature 27 C DB / 19 C WB - medium fanspeed ***water inlet temperature 18 C and water outlet temperature 23 C, room temperature 27 C DB / 19 C WB - medium fanspeed 39

Daikin solar system Solar connection 1 Daikin offers two types of solar systems in combination with their heat pumps. 2 3 Pressureless system The system is filled with pure water which is transferred from the pressureless energy storage tank, whenever the sun is out. If no sun is out and thus no energy is needed, the water is drained back into the pressureless energy storage tank. Pressurised system The system is filled with heat transfer fluid with the correct amount of of antifreeze to avoid freezing in winter. The whole system is then pressurised and sealed. Solar kit The solar kit provides the transfer of solar heat to the Daikin Altherma hot water tank via an external heat exchanger. In contrast to tanks with two heat exchangers, this system allows the entire content of the tank to be efficiently heated with solar heat and, if necessary, with heat pump energy. Solar collector The high-efficiency collectors transfer all the short-wave solar radiation into heat as a result of their highly selective coating. The collectors can be mounted on the tiles. 1- Solar collector 2- Solar pump station 3- Solar kit available in combination with stand alone (EKHWS - EKHWE) domestic hot water tank What do you need? Solar collector Plumbing network and solar pump station Supply tank: standard Daikin Altherma domestic hot water tank Solar kit Re-heater (Daikin Altherma heat pump unit which also provides the home with heating) 4

Daikin solar system Solar collectors Averaged over an entire year, the sun delivers half of the energy we need to bring our domestic hot water up to the desired temperature. High-efficiency collectors with highly selective coating transfer all the short-wave solar radiation into heat. The collectors can be mounted on tiles. Operation The solar collectors are only filled with water when sufficient heat is provided by the sun. In this case, both pumps in the control and pump unit switch on briefly and fill the collectors with storage tank water. After filling, which takes less than a minute, one of the pumps switches off and water circulation is maintained by the remaining pump. Solar collector Indoor unit and domestic hot water tank EKHWP: domestic hot water tank The domestic hot water tank has two sections: The upper, always hot, section the active water zone and the lower, colder section the solar zone. 1. The active water is heated in the upper section of the storage tank. The high temperature of this zone ensures that sufficient hot water is always available. 2. Solar collectors work more efficiently when colder water flows through the solar collectors. Therefore, the water that is fed directly to the solar collectors in solar operation is stored in the solar zone. 1 2 4 3 14 13 12 65 7 1. Cold water connection 12. Fill level indicator 2. Hot water connection 13. Connection for booster heater 1 1 3. Storage tank charging flow 14. Electric immersion booster heater 21 16 9 17 8 18 9 24 11 4. Storage tank charging return flow 5. Heating support flow 6. Heating support return 7. Drain Back solar flow 8. Storage tank (polypropylene double walled jacket with PUR hard foam heat insulation) 9. Mount for solar R3 controller / handle 1. Safety overflow connection 15. Sensor pocket for tank temperature sensor 16. Domestic hot water heat exchanger 17. Charging heat exchanger 18. Inlet from solar collector 19. Pressure-free storage tank water 2. Solar zone 21. Hot water zone 2 23 19 15 11. Drain-back solar - return flow / Filling and draining connection for storage tank water 41

Daikin solar system Technical specifications SOLAR CONNECTION EKSOLHWAV1 Dimensions Unit H x W x D mm 77x35x27 Weight Unit kg 8 Operation Ambient Min,~Max, C range temperature 1~35 Sound pressure Nom, dba level 27 Thermal Zero loss collector efficiency η % performance - Power supply Phase/Frequency/Voltage Hz/V 1~/5/22-24 Power supply intake Indoor unit ACCESSORY EKSR3PA Mounting On wall Dimensions Unit H x W x D mm 332x23x145 Thermal Zero loss collector efficiency η % performance - Control Type Digital temperature difference controller with plain text display Power consumption W 2 Sensor Solar panel temperature sensor Pt1 Storage tank sensor PTC Return flow sensor PTC Feed temperature and flow sensor Voltage signal (3,5V DC) Power supply Frequency/Voltage Hz/V 5/23 SOLAR COLLECTOR EKSV26P EKSH26P EKSV21P Dimensions Unit H x W x D mm 2,x1,3x85 1,3x2,x85 2,x1,6x85 Weight Unit kg 42 35 Volume l 1,7 2,1 1,3 Surface Outer m² 2,61 2,1 Aperture m² 2,364 1,795 Absorber m² 2,354 1,791 Coating Micro-therm (absorption max,96%, Emission ca, 5% +/-2%) Absorber Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate Glazing Single pane safety glass, transmission +/- 92% Allowed Min,~Max, C angle 15~8 Operating Max, bar pressure 6 Stand still Max, C temperature 2 Thermal Zero loss collector efficiency η % 78,7 78,3 performance Heat loss coefficient a1 W/m²,K 4,27 4,25 Temperature dependence of W/ the heat loss coefficient a2 m²,k²,7,57 Thermal capacity kj/k 6,5 - Incident AM at 5 angle modifier,94 - Installed position Vertical Horizontal Vertical SOLAR CONNECTION EKSRPS3B Dimensions Unit H x W x D mm - Control Type Digital temperature difference controller with plain text display Power consumption W - Mounting On side of tank Sensor Solar panel temperature sensor Pt1 Storage tank sensor PTC Return flow sensor PTC Feed temperature and flow sensor Voltage signal (3,5V DC) 42

Daikin solar system Pricelist For Daikin Altherma LT, HT and Flex units a pressurised and pressureless solar system is available. Main components are the standard Daikin tanks as well as pressureless hygienic domestic hot water tanks, combined with Daikin s solar kits and controllers and solar panels for on-, in- and flat installations. EKSH26P EKSV21P Horizontal big solar panel 2 x 13 mm Vertical small solar panel 2 x 16 mm Material Description Price per unit Solar Panel EKSV26P Vertical big solar panel 2 x 13 mm 721,- 741,- 584,- Daikin hot water tanks & accessories EKHWS* Stainless steel tank see page 9 EKHWE* Enameled tank see page 9 EKSOLHW Solar heat exchanger kit 851,- EKHWP3B Hygienic Domestic hot water tank, 3l 2.234,- EKHWP5B Hygienic Domestic hot water tank, 5l 2.211,- 1657 Set of 2 gravity brakes 14,- 16412-RTX FLG FLG - flow regulating valve with flow rate indicator 73,- 15615 VTA32 Thermostatic antiscald mixing valve 92,- 15616 1 screw connection set for VTA32 37,- 1627 MAGS12 Solar Expansion Vessel 12L 14,- 1625 MAGS25 Solar Expansion Vessel 25L 171,- 16251-RTX MAGS35 Solar Expansion Vessel 35L 263,- Solar Controlers & Pump Stations EKSRPS3B Solar controller for drain back applications 843,- EKSR3PA Solar controller for pressurized applications 376,- EKSRDS1A Solar pump station 558,- 164116 Flow sensor for a pressurized system 177,- Solar priority PCB + cable EKRP1HBA PCB kit to disable hot water mode through HP during solar water heating 152,- 16411-RTX BSKK Solar priority cable / connection cable to disable heatpump 21,- Solar panel installation accessories 164732 CON15 Pressureless Connection piping between solar panel & pump station: 15m 167,- 164733 CON2 Pressureless Connection piping between solar panel & pump station: 2m 2,- 164261-RTX CONX25 Pressureless elongation pipe 2,5m including couplings 15,- 164262-RTX CONX5 Pressureless elongation pipe 5m including couplings 119,- 164263 CONX1 Pressureless elongation pipe 1m including couplings 155,- 164264 CONXV8 Pressureless elongation for inlet pipe 8m 134,- 16273 CON15P16 Pressure solar pipe DN16-15m 64,- 16271 CONXP16 Connectors DN16 14,- 16274 CON15P2 Pressure solar pipe DN2-15m 747,- 16272 CONXP2 Connectors DN2 21,- 16275 CONCP16 Pressure solar connection set DN 16 74,- 16276 CONCP2 Pressure solar connection set DN 2 18,- EKSRCRP Connection kit, incl. red tile 31,- EKSRCAP Connection kit, incl. anthracite tile 31,- EKSRCP Connection kit ON ROOF 217,- 16237-RTX RCIP Mounting kit IN-ROOF 165,- 16238-RTX RCFP Mounting kit FLAT ROOF 317,- 16479 CONFE Additional breakthrough for opposite side connection 97,- 16216-RTX FIXVBP Connection kit between 2 solar panels 68,- 16235-RTX CONRVP Connection kit between 2 rows of collectors 88,- 16245 CONLCP Connection kit between 2 rows of collectors 134,- 16266 FIXMP1 Mounting rail for V21 49,- 16267 FIXMP13 Mounting rail for V26P 54,- 16268 FIXMP2 Mounting rail for H26P 73,- 164245 TS Suporting shell for pressureless connection pipe 9,- 16236-RTX FIXADP Variable height mounting set for on- mounting suitable for tiles 119,- 16269 FIXADD Standard mounting set for on- mounting suitable for tiles 23,- 164723 FIXADS Mounting set for on- mounting suitable for flat tiles e.g. shingles 7,- 16473-RTX FIXWD Mounting set for on- mounting suitable for corrugated plates 68,- 16474-RTX FIXBD Mounting set for on- mounting suitable for metal s 81,- 16217 IBV21P Basic IN ROOF installation kit for 2 EKSV21P 64,- 16218 IEV21P Extension IN ROOF installation kit for 1 additional EKSV21P 27,- 16219 IBV26P Basic IN ROOF installation kit for 2 EKSV26P 645,- 1622 IEV26P Extension IN ROOF installation kit for 1 additional EKSV26P 282,- 164616-RTX FIXIES IN ROOF covering slate complementing kit 158,- 16258 FBV26P Basic FLAT ROOF support frame for 2 EKSV26P 725,- 16259 FEV26P Extension FLAT ROOF support frame for additional EKSV26P 29,- 1626 FBH26P Basic FLAT ROOF support frame for 1 EKSH26P 343,- 16261 FEH26P Extension FLAT ROOF support frame for additional EKSH26P 223,- 16229-RTX FIXLP Release tool 9,- 16252-RTX GFL 2l ready to use glycol T min = -28 C 114,- 43

Daikin solar system Drain back combination tables EKSV21P Drain back # of panels 2 3 4 5 Material On In On In On In On In EKSV21P 2 2 3 3 4 4 5 5 FIXVBP 1 1 2 2 3 3 4 4 FIXMP1 2 2 3 3 4 4 5 5 FIXADP FIXADS FIXWD FIXDB IBV21P 2 1 3 1 4 1 5 1 IEV21P 1 2 3 EKHWP***B 1 1 1 1 1 1 1 1 EKSRPS3B 1 1 1 1 1 1 1 1 EKRP1HBA 1 1 1 1 1 1 1 1 BSKK 1 1 1 1 1 1 1 1 FLG 1* 1* 1* 1* 1* 1* 1* 1* TS 1 1 1 1 1 1 1 1 CON15 1 1 1 1 1 1 1 1 EKSRCAP/EKSRCRP 1 1 1 1 RCIP 1 1 1 1 * : optional (recommended) EKSH26P Drain back # of panels 1 2 3 4 5 Material On Flat On Flat On Flat On Flat On Flat EKSH21P 1 1 2 2 3 3 4 4 5 5 FIXVBP 1 1 2 2 3 3 4 4 FIXMP2 1 1 2 2 3 3 4 4 5 5 FIXADP FIXADS FIXWD FIXDB FBH26P 1 1 2 1 3 1 4 1 5 1 FEH26P 1 2 3 4 EKHWP***B 1 1 1 1 1 1 1 1 1 1 EKSRPS3B 1 1 1 1 1 1 1 1 1 1 EKRP1HBA 1 1 1 1 1 1 1 1 1 1 BSKK 1 1 1 1 1 1 1 1 1 1 FLG 1* 1* 1* 1* 1* 1* 1* 1* 1* 1* TS 1 1 1 1 1 1 1 1 1 1 CON15 1 1 1 1 1 1 1 1 1 1 EKSRCAP/EKSRCRP 1 1 1 1 1 RCFP 1 1 1 1 1 * : optional (recommended) EKSV26P Drain back # of panels 2 3 4 5 Material On In Flat On In Flat On In Flat On In Flat Roof EKSV26P 2 2 2 3 3 3 4 4 4 5 5 5 FIXVBP 1 1 1 2 2 2 3 3 3 4 4 4 FIXMP13 2 2 2 3 3 3 4 4 4 5 5 5 FIXADP FIXADS FIXWD FIXDB IBV26P 2 1 3 1 4 1 5 1 IEV26P 1 2 3 FBV26P 1 1 1 1 FEV26P 1 2 3 EKHWP***B 1 1 1 1 1 1 1 1 1 1 1 1 EKSRPS3B 1 1 1 1 1 1 1 1 1 1 1 1 EKRP1HBA 1 1 1 1 1 1 1 1 1 1 1 1 BSKK 1 1 1 1 1 1 1 1 1 1 1 1 FLG 1* 1* 1* 1* 1* 1* 1* 1* 1* 1* 1* 1* TS 1 1 1 1 1 1 1 1 1 1 1 1 CON15 1 1 1 1 1 1 1 1 1 1 1 1 EKSRCAP/EKSRCRP 1 1 1 1 RCIP 1 1 1 1 RCFP 1 1 1 1 * : optional (recommended) Additional items drain back in function of installation Material Description Required quantity 1657 Gravity brakes 1 set per tank heat exchanger adviced if piping from heat exchanger is not making downward bend at the tank CONX25 CONX1 CONX5 CONXV8 Elongation sets Elongation pipe with couplings for inlet 8 m Depending on required elongation Only required if transit of outlet pipe collector can not be located next to outlet connection of solar collector CONRVP Connection pipe between solar panel rows Number of rows - 1; Remove 1 FIXVBP per CONRVP 44

Daikin solar system Pressurised combination tables EKSV21P Pressurised # of panels 2 3 4 Material On In On In On In EKSV21P 2 2 3 3 4 4 FIXVBP 1 1 2 2 3 3 FIXMP1 2 2 3 3 4 4 FIXADD 6 1 12 standard tiles FIXADP FIXWD FIXDB IBV21P 2 1 3 1 4 1 other types IEV21P 1 2 EKHWS / EKHWE 1 1 1 1 1 1 EKSOLHWAV1 1 1 1 1 1 1 EKSRDS1A 1 1 1 1 1 1 164116 1 1 1 1 1 1 EKSR3PA 1 1 1 1 1 1 FLG 1* 1* 1* 1* 1* 1* CON15P16 1 1 1 1 CONCP16 1 1 1 1 CON15P2 1 1 CONCP2 1 1 MAGS12 1 1 MAGS25 1 1 MAGS35 1 1 EKSRCP 1 1 1 1 1 1 GFL Depending on system volume * : optional (recommended) EKSV26P Pressurised # of panels 1 2 3 Material On In Flat On In Flat On In Flat EKSV26P 1 2 2 2 3 3 3 FIXVBP 1 1 1 2 2 2 FIXMP13 1 2 2 2 3 3 3 FIXADD 4 6 1 standard tiles FIXADP FIXWD 1 2 3 FIXDB IBV26P 1 1 IEV26P 1 FBV26P 1 1 FEV26P 1 EKHWS / EKHWE 1 1 1 1 1 1 1 EKSOLHWAV1 1 1 1 1 1 1 1 EKSRDS1A 1 1 1 1 1 1 1 164116 1 1 1 1 1 1 1 EKSR3PA 1 1 1 1 1 1 1 FLG 1* 1* 1* 1* 1* 1* 1* CON15P16 1 1 1 1 1 1 1 CONCP16 1 1 1 1 1 1 1 MAGS12 1 1 1 1 MAGS25 1 1 1 EKSRCP 1 1 1 1 1 1 1 GFL Depending on system volume * : optional (recommended) other types EKSH26P Pressurised # of panels 1 2 3 Material On Flat On Flat On Flat EKSH21P 1 1 2 2 3 3 FIXVBP 1 1 2 2 FIXMP2 1 1 2 2 3 3 FIXADD 4 6 1 standard tiles FIXADP FIXWD FIXDB FBH26P 1 1 2 1 3 1 other types FEH26P 1 2 EKHWS / EKHWE 1 1 1 1 1 1 EKSOLHWAV1 1 1 1 1 1 1 EKSRDS1A 1 1 1 1 1 1 164116 1 1 1 1 1 1 EKSR3PA 1 1 1 1 1 1 FLG 1* 1* 1* 1* 1* 1* CON15P16 1 1 1 1 1 1 CONCP16 1 1 1 1 1 1 MAGS25 1 1 1 1 1 1 EKSRCP 1 1 1 1 1 1 GFL Depending on system volume * : optional (recommended) Additional items pressurised in function of installation Material Description Required quantity CONLCP Connection pipe between solar panel rows Number of rows - 1; Remove 1 FIXVBP per CONLCP CONXP16 Connection between 2 CON15P16 Additional CON15P16 needed CONXP2 Connection between 2 CON15P2 Additional CON15P2 needed 45

Notes 46

Commercial terms and conditions I. GENERAL Our deliveries and services are exclusively subject to the following terms and conditions of sale and delivery, even if the customer provides otherwise. The ordering party s counter-confirmations in reliance on his commercial terms and conditions or his terms and conditions of purchase apply only if they are consistent with these terms and conditions of delivery. Acceptance of the goods is in any event deemed to constitute an acknowledgment of our terms and conditions of sale and delivery. Any deviating modifications and amendments require our express consent and must be made in writing to be legally valid. Our commercial terms and conditions can be found at www.daikin-ce.com. II. OFFER Our offers are without engagement and non-binding. Any information about dimensions, weights, technical data, quantities and delivery times is non-binding. III. PLACING OF AN ORDER, CHANGE OF THE DELIVERABLE 1. Orders must be placed in writing (by letter, fax or email). We are deemed to have accepted an order not until after we have confirmed in writing or actually executed that order. Any arrangement and agreement reached verbally and by phone must be confirmed in writing. 2. We reserve the right to rescind the contract even after having accepted an order if information we have obtained about the customer s liquidity in the meantime suggests that the customer will not be able to pay for the entire or for part of the order. 3. Having accepted an order, we also reserve the right to change and improve the service or deliverable, e.g. in respect of its type and design, to the extent the customer can be reasonably expected to accept such changes and improvements in consideration of our interests (e.g. delivery of an equivalent or more sophisticated device). Such changes and improvements are deemed approved in advance. 4. The customer s cancellation or change of an entire or of part of an order requires our written consent and entitles us to charge the customer - in addition to the services already provided and costs accrued - a (cancellation) fee equal to 2 % of the order value and at least 25. For certain product groups (e.g. multiple scroll, screw chiller), separate cancellation rules apply which can be found at www.daikin-ce.com. IV. PRICES AND TERMS OF PAYMENT 1. Prices are based on the price list, as amended from time to time, which is usually issued once a year. We reserve the right to change prices also during a year. 2. Prices are understood to be net prices without any taxes, duties or charges in the quoted currency, including packaging, ex our forwarding warehouse, unless otherwise indicated. We will not take back packaging and packing material. 3. We will not accept any objections to invoices which are received more than two weeks after receipt of an invoice. Unless otherwise indicated, invoices are due net 3 days from the invoice date; the payment date is the date on which a payment is received by us. In case of late payment, we will charge default interest at a rate of 12% p.a. In case of default, we may also demand all costs related to the collection of our claim, including, without limitation, dunning and collection charges. 4. If payment by instalments has been agreed, the maturity date will be accelerated if the customer is in default in respect of only one instalment. 5. We may make deliveries dependent on advance payment. 6. The customer may not withhold or set off payments in reliance on warranty or other claims. V. DELIVERY TIME 1. Indicated delivery times are non-binding and reference times only, although we endeavour to meet indicated deadlines. The customer has no right to insist on compliance with a certain delivery time. As a consequence, delays in delivery will not entail any claims for damages and do not entitle the customer to rescind the contract. The same holds true if delivery deadlines are not met due to force majeure, strike or other events outside our control. 2. We will not accept penalty claims asserted by the customer under any circumstances. 3. Partial deliveries are permitted. 4. If the ordering party is in arrears on an earlier delivery, Daikin may withhold deliveries pending payment of the earlier delivery and is not required to pay to the ordering party any damages in this respect. VI. ACCEPTANCE OF DELIVERIES, TRANSFER OF RISK, DELAYED ACCEPTANCE 1. Unless otherwise agreed, deliveries are made CIP (Incoterms 21) to the named destination 2. In principle, delivery CIP covers only minimum transport insurance. Additional transport insurance will be purchased only if explicitly requested by customer and subject to a separate agreement and at the customer s cost and expense. 3. The customer must immediately check deliverables received by him or directly by his customers for any transport damage, and he must record any damage to the packaging or the device in the delivery note and shall refuse delivery towards the forwarding agent. If the customer finds out only later that goods are damaged, the customer shall report any such damage to us, immediately, in no case later than three working days after delivery; otherwise, any insurance claim may expire. 4. If the customer accepts goods with delay, we - notwithstanding our other rights - may charge the goods as delivered or may otherwise dispose of them @ setting a time limit. If we otherwise dispose of the goods, the delivery time will recommence on the day we receive the customer s written request calling for delivery of the goods. 5. We may charge the customer for any costs incurred due to late acceptance, including, without limitation, any storage costs. VII. RESERVATION OF TITLE 1. We will retain title to goods delivered pending full payment of all claims arising from our business relationship with the customer, even if the purchase price for specifically designated claims was paid. If our conditional goods are processed, we will acquire title to the new item without consideration. If the goods delivered by us are mixed, processed or combined with other items, the customer hereby assigns to us in proportion of the value of our invoices an ownership or co-ownership right of the combined or new item, both in respect of the interim and the final products. 2. The customer may resell goods delivered by us and the items created by processing, mixing or combining these only in the ordinary course of business. The customer hereby assigns to us any claims arising from such resale or from any other legal ground toward third parties, including, ancillary rights, in order to secure our - future - claims that may arise from our business relationship. The customer must record the assignment of these claims in his books not later than when the goods are resold. 3. Before having paid the purchase price of an item, the customer may resell that item only if he simultaneously informs the second buyer (end customer) that the resale proceeds have previously been assigned. 4. The customer may collect the assigned claims as long as he fulfils his payment obligations towards us according to the terms of the contract. The customer may not otherwise dispose of the conditional goods (e.g.: transfer of property by way of security, pledging). 5. The customer must immediately inform us of any attachment or other impairment of the conditional goods and/or the assigned claims and explain to the third party that we have retained title to those goods. Any related cost will be borne by the customer. VIII. WARRANTY AND LIABILITY A. Unless otherwise agreed and to the exclusion of any further claims, we are liable for any defects and the absence of warranted qualities as follows: 1. Unless otherwise indicated below, the warranty period is 36 months of the delivery date (delivery to the forwarding agent). This does not affect the applicability of Section 924 of the Austrian Civil Code. 2. The customer may assert a warranty claim only if the equipment is both installed and put into operation by Daikin or a company trained by Daikin according to the Daikin installation instructions and regularly maintained according to the Daikin service notes. Refrigerating machines featuring screw-type compressors include a 12-month warranty claim only if the machine was put into operation by Daikin itself. In case of products designated J&E Hall International for Daikin the customer may assert an 18-month warranty claim. For Rotex branded products generally a 24-month warranty period is valid except for following variations: 1 years for underfloor heating pipes and system plates, VA-piping and variosafe oil storage tanks. 5 years for solar panels, variosystem and highcube oil tanks and variocistern rainwater tanks. 3 years for HPSU heat pump solar unit and hot water storage tanks HYC, SCS and SC. 3. In a warranty event, we undertake, at our election, to replace or repair the defective goods or components. The customer may not assert other warranty or guarantee claims whatsoever. Labour cost, travel times or other costs will not be reimbursed. 4. No warranty and/or liability is accepted, unless the customer reports visible defects by giving written notice within 3 working days of delivery and other defects without delay after these have been discovered. 5. In addition to paragraphs 2 and 4, no warranty and/or liability is accepted for defects that have been caused by inadequate or improper use or treatment, failure to observe operating conditions or maintenance guideless, excessive use or inadequate operating facilities or substitute materials. 6. Unless we are granted the required time and opportunity to take all necessary warranty measures, we are released from any warranty claims and damages. If the customer continues to use defective goods, we warrant and/or are liable only for the original defect. We will not reimburse any cost of repairs which are carried out without our express prior consent. We disclaim any liability for the consequences of such repairs. 7. The warranty period for spare parts and other improvements is 6 months of delivery (delivery to the forwarding agent). 8. If a defect is remedied, the warranty period will not recommence for the replaced or repaired components. 9. We may refuse to remedy defects as long as the customer is in default with his payment obligations. The customer has no right to withhold payments, even if he gave justified notice of defects. 1. If third-party products are delivered and installed, warranty is restricted to assigning the warranty claims we may assert against the supplier of the third-party product. The customer may not assert any other warranty claims and may particularly not claim a price reduction. B. We are liable for damage only if we demonstrably acted with intent or gross negligence. We disclaim any liability for slight negligence. We are particularly not liable for consequential damage (e.g. idle times due to wrong deliveries) and financial loss, lost profit, unachieved savings, loss of interest and any damage suffered from thirdparty claims against the customer, unless the foregoing is attributable to our intent or gross negligence. If damage is attributable to the defective condition of goods delivered by us, we are liable only to the extent the producer or upstream supplier is liable to us. Our liability does in any case not exceed the invoice value of the incriminated goods. IX. RETURNED GOODS 1. Goods can be returned and exchanged only upon our express and written consent. We accept returned goods only with a minimum net value of 1, and a maximum net value of 5., and only provided that those goods are not damaged, have not been used, are in original packaging and are fit for resale. In particular, returns of already installed units (including chillers) and returns of any made to order units as well as spare parts are not permitted. 2. The customer shall complete the Request for Goods Return -form (available at the DENV Extranet, http:\\extranet.daikineurope.com) and send it to us to the fax number or email address provided by us within 1 calendar days after delivery, otherwise we will not accept the return. 3. Goods must be returned freight paid at the risk of customer to the destination indicated by us. 4. In every case of a return, a maximum of 8% of the net price charged by us to the customer will be credited. All standard returns will be subject to a restocking / administration charge of 2 % of the net price. 5. All returns will be inspected by us. If goods are returned wrongly (i.e. not in compliance with paragraph 1. above), we may refuse the returns and have them returned back to the customer at the customer s risk and costs. Alternatively, we may charge a higher restocking / administration fee than the above mentioned 2%. 6. Any credit notes whatsoever will exclusively be set off against future deliveries. X. PLACE OF JURISDICTION, APPLICABLE LAW 1. All disputes arising from or in connection with this Agreement shall be exclusively referred to the courts in Vienna. 2. All contracts concluded by us and all disputes arising in connection with those contracts shall be governed by and construed in accordance with Austrian law without giving effect to its conflict of law rules and the UN Sales Convention. XI. SEVERABILITY Should any term of these commercial terms and conditions or of the contract concluded between us and the customer be invalid or ineffective, this shall not affect the remaining terms hereof or thereof. Invalid terms shall be replaced by lawful terms which closest reflect the parties intent. The Daikin Commercial terms and conditions are also available in the internet at http://www.daikin-ce.com Campus 21, Europaring F12/42 A-2345 Brunn am Gebirge, Austria phone +43 2236 32557, fax +43 2236 32557-9, office@daikin-ce.com, www.daikin-ce.com 47

Daikin Altherma hybrid heat pump The natural combination Up to 35% efficiency increase compared to condensing boiler Gas condensing boiler of 33 kw Most economical mode to operate Heating and domestic hot water Hybrid technology COP in heat pump operation: 5.4 The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V./Daikin Central Europe HandelsGmbH. Daikin Europe N.V./Daikin Central Europe HandelsGmbH has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V./Daikin Central Europe HandelsGmbH explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. DAIKIN AIRCONDITIONING CENTRAL EUROPE HandelsgmbH campus 21, Europaring F12/42, A 2345 Brunn am Gebirge Tel.: +43 / 22 36 / 3 25 57, Fax: +43 / 22 36 / 3 25 57-9 e-mail: office@daikin.at, www.daikin-ce.com Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com Daikin Products are distributed by: DACE Heating Pricelist for Serbia&Montenegro 215 Version 1 Copyright Daikin We reserve the right for printing errors and model changes.