Installation Instructions

Similar documents
Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

Refrigerant Recovery Machine. Model No Operating Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

Operation and Maintenance Manual

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual

Up to 60 Pint Commercial Grade DEHUMIDIFIER

Installation Manual Mopar Engine Compartment Upgrade Kit

R100 Oil-Less Refrigerant Recovery Unit

OPERATION & MAINTENANCE MANUAL AC860

Operator s Manual. Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY

INSTRUCTION MANUAL 4HP WET / DRY VACUUM VC V 60 Hz 7A. Gal

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

FLOOD KING 120V. 2. Keep all filters clean. Do not operate the machine if the filters are clogged.

Operator s Manual. 6 Gallon Model No. VQ607SFD FOR YOUR SAFETY. Read and understand this manual before use Keep this manual for future reference

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

OPERATOR S MANUAL. BASIC PROJECT CENTERS Some instructions and drawings may not apply to your specific unit. SAFETY SERVICE PARTS CAPACITIES

OPER LV Wheeler Way

HEATING AND AIR CONDITIONING

Transmission Cooling System J Operation Manual. TRANSFLOW Transmission Cooling System Service Tool J

OPERATING MANUAL. Model 34134Z. Refrigerant Unit Recover, Recycle, and Recharge

SCN60 Residential Nugget Ice Machine

INSTALLATION & OPERATION MANUAL

INSTALLATION INSTRUCTIONS

TOYOTA FJ-40 DIRECTIONS

Installation Instructions for Models: HES232U, HES236UHES246U, HES247U, HES245U, HES242U, HES256U, HES255U, HES252U

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

ADVANTAGE-100H-SC EXTRACTOR

D14 & D18 Upright Vacuum

INSTALLATION INSTRUCTIONS PT-A HEAT/AC STANDARD KIT FORD E-SERIES VANS

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic hi l PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST FORD TRUCK

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

Desoldering Tool. (HAKKO FR-4102) Instruction Manual. Table of Contents

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST MUSTANG

OPERATION & MAINTENANCE MANUAL RHS680

SERVICE BULLETIN A

Installation Manual Chevrolet Vehicles

Jiffy J-2000 Model Steamer FEATURES

E n g l i s h M a n u a l

OPERATING INSTRUCTIONS DUST EXTRACTOR FM300S

Shredder FD 8906CC Cross-Cut

Operator s Manual. 2.5 Gallon Model No. VOM205P FOR YOUR SAFETY. Read and understand this manual before use. Keep this manual for future reference.

TRS21 IGNITION PROOF SERIES

A/C Refrigerant. Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car

USING R-134A REFRIGERANT

Operating Manual. Series 12134B Recovery/Recycling/Recharging Unit for R-12 and R-134a

Installation. Leveling

OPERATOR S MANUAL STANDARD BALL BEARING CHESTS & ROLLER CABINETS

OWNER S OPERATING MANUAL DC-1200P DUST COLLECTOR

347002K/177002K/34900

IMAGE V. Parts and Service Manual

INSTALLATION GUIDE. S700M & S800A Workstations. Technical Assistance call (800)

TRS21 IGNITION PROOF SERIES

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)


HEAT/ COOL/ DEFROST FORD THUNDERBIRD

OPERATOR S MANUAL FOR YOUR SAFETY. 4 Gallon / Liter Part No. PB408SV

Unpacking, Assembly, and Installation Guide ENGLISH. Page 1 to 10

IJ3000 IJ3000 Flushing System N Revision B Installation Instructions Page 1 of 10

Model K / K. Modelo K / K. Modèle K / K. Operating Manual

Corp L9 Revised HS27 SERIES UNITS SPECIFICATIONS. Model No. HS HS HS HS27-042

Oilless Refrigerant Recovery System. OWNER S MANUAL (English) TO BE OPERATED BY QUALIFIED PERSONNEL ONLY

Operator s Manual Manual Del Usuario

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Scotsman Technical Training. CU50 Cube Ice Machine

Operating Manual for. Model Recovery, Recycling, Recharging Unit

Owner s Manual Hydro-X Vacuum Pac

Hoshizaki America, Inc.

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET CHEVELLE/ EL CAMINO NOTE: INSTRUCTIONS DEPICT CHEVELLE

EVac II Programmable Digital Vacuum Gauge

MF90 Series Portable Filters (CE)

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

S - SERIES IN-WALL SERIES INSTALLATION MANUAL

5. MVAC-like appliance include appliances using R22 refrigerant a. True b. False

User Instructions. Visit us at us at RB5, RB10, RB15 Maple Sap Buckets

Best Practices for Mobile A/C Refrigerant System Service

1998 Expedition/Navigator Workshop Manual

Installation Instructions

OPERATION & MAINTENANCE MANUAL TX600

51AKS I S O OWNER S MANUAL

CONSTANT SUCTION UNIT

Si Ud. o sus operadores no pueden leer el Inglés, se hagan explicar este manual completamente antes de tratar el manejo o servicio de esta máquina.

Installation Instructions

Caresaver Universal Refrigerant Recovery Unit

CART & TROUGH ASSEMBLY for BRAISING PAN UNITS

Operating Manual Manual de Operación Manuel d utilisation

USER MANUAL UN-200V / UN-200VH

Wet/Dry Vacuum Kit

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

Ductless Split Air Conditioner

HS25 SERVICE UNIT INFORMATION

FiberPRO 2.5 H. Heated Spot Extractor. Operator and Parts Manual E

SECAP Conveyor TC72 / Dryer TD72

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

120V CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

2001 Smith Eastern Corporation

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST EARLY 1955 CHEVROLET PICKUP

Climate Control System

Model K 280 M Part No

INSTALLATION. Glass Panel Doors (select models) CAUTION

Transcription:

Model: Page: ACT-3120 ACT-3340 Page 1 of 6 Installation Instructions INSTALLATION MUST BE PERFORMED BY QUALIFIED SNAP-ON/SUN PERSONNEL ONLY INSTALLATION OVERVIEW: This Installation Instructions will prepare the ACT-3120/3340 for operation. The unit is shipped as a fully assembled unit, with the exception of the items as listed in the Parts & Accessories list per tester. PLEASE READ THESE INSTRUCTIONS COMPLETELY BEFORE SETTING UP UNIT.! CAUTION! THIS UNIT MUST BE PLUGGED IN TO A PROPER AC OUTLET FOR UNIT TO OPERATE CORRECTLY. REFER TO UNIT ID PLATE LOCATED ON BACK OF UNIT. EXTENSION CORDS ARE NOT RECOMMENDED, BUT IF AN EXTENSION CORD MUST BE USED, USE A CORD THAT IS LESS THAN 50 FEET WITH A 16 AWG, OR ABOVE 50 FEET AND LESS THAN 100 FEET WITH A 14 AWG.! WARNING! USE STANDARD REFRIGERANT HANDLING SAFETY PROCEDURES WHEN PERFORMING INSTALLATION ALWAYS WEAR SAFETY GOGGLES, DON'T SPILL OR TOUCH LIQUID REFRIGERANT, AVOID FLAMES, & EXCESSIVE HEAT. USE ONLY IN WELL VENTILATED AREA.

PAGE 2 OF 6 PARTS & ACCESSORIES LIST FOR ACT-3120: PART NUMBER DESCRIPTION QTY 0001-0067-01 Wrench, Suction Separator Bowl 1 0119-0356-01 Literature Kit, ACT-3120 1 0403-1541-08 Screw #10-32 x 1/2" (May be Installed) 2 0647-0196-01 Adapter, GM 1 0647-0197-01 Adapter, Quick-Disconnect, GM/Ford 1 0647-0199-01 Adapter, Quick-Disconnect, GM/Ford 1 0647-0200-01 Adapter, Ford 1 0671-1026-01 Desiccant Bag 10 0675-0423 Screw 1/4-20 x 3/8" 2 0692-2231-01 Installation Instructions 1 4211-0001-01 Envelope 1 7009-2417-01 Inline Filter 1 7009-2447-03 Recovery Tank Assembly 1 7012-1369-01 Bracket, Hose 1 7012-1537-01 Bracket, Gauge 1 EAH0013C00A Gauge Set, Uniweld 1 PARTS & ACCESSORIES LIST FOR ACT-3340: PART NUMBER DESCRIPTION QTY 0001-0067-01 Wrench, Suction Separator Bowl 1 0119-0357-01 Literature Kit, ACT-3340 1 0403-1541-08 Screw #10-32 x 1/2" (May be Installed) 2 0671-1018-02 Desiccant Bag 10 0675-0423 Screw 1/4-20 x 3/8" 2 0692-2231-01 Installation Instructions 1 4211-0001-01 Envelope 1 7009-2418-01 Inline Filter 1 7009-2447-01 Recovery Tank Assembly 1 7012-1369-01 Bracket, Hose 1 7012-1537-01 Bracket, Gauge 1 EAH0014C00A Gauge Set, Uniweld 1 REQUIRED TOOLS: Screw Driver (Flat Blade & Phillips) Safety Goggles (0001-5005) Refrigerant Oil (Mineral)

UNPACKING UNIT AND ACCESSORIES: 1. Cut Straps, and slide the carton off the pallet. 2. Remove the top of the carton, top packing, and carton sides. Split the corners of the base carton. 3. Lean the unit so it can be rolled off the base. 4. Remove all boxes and packing material from scale/tank compartment. 5. Inventory all items using the Parts & Accessories list and inspect for damage. PARTS & ACCESSORIES SETUP: 1. Mount the Hose Bracket to the rear panel using the two Screws (1/4-20 x 3/8") supplied. 2. Mount the Gauge Set Bracket to the rear top panel using the two Screws (#10-32 x 1/2") supplied. 3. Remove the Gauge Set Assembly from the box and place on Gauge Set Bracket. 4. Remove the Blue and Red Hoses from box and OIL the seals on each end. 5. Connect the Blue and Red Hoses to the Gauge Set respectively. Be sure to connect the open end of the hose to the Gauge Set fittings. 6. For the ACT-3120, place the four adapters in the Storage Compartment on top of unit. 7. For the ACT-3340, connect the Red and Blue adapters (supplied in Gauge Set box) to the Red and Blue Hoses from the Gauge Set. 8. Place the Desiccant bags, and Filter Wrench in the Storage Compartment on top of unit. 9. Remove the User's Manual from the Literature Kit, and place the remainder of the Literature Kit (0119-0356-01 or 0119-0357-01) in the Storage Compartment on top of unit. BE SURE TO REVIEW THE USER'S MANUAL WITH THE CUSTOMER DURING TRAINING. Then before installing the User's Manual Envelope, ask where the customer would like the envelope installed. 10. Peel the backing from the User's Manual Envelope (4211-0001-01) and apply the envelope, with the open end on top, to either side of the unit or in the location designated by the customer. 11. Place the User's Manual in the Envelope. 12. Remove Cap on front of unit from Service Port. OIL the seal on the Inline Filter and attach to the service port on front of unit. (SEE USER'S MANUAL) 13. Remove Recovery Tank from box. Remove cardboard wrap from Recovery Tank. Set on floor in front of unit. PREPARING NEW RECOVERY TANK: PAGE 3 OF 6 1. Open BLUE valve on Recovery Tank to release ALL COMPRESSED AIR. 2. Remove the Inline Filter from Recovery Tank. OIL seal, and re-attach to Recovery Tank. (BLUE SIDE) 3. Remove the Yellow Hose from box. OIL the seals on each end of hose.

PAGE 4 OF 6 PREPARING NEW RECOVERY TANK continue... 4. Attach open end of Yellow Hose to BLUE valve of Recovery Tank. Attach other end of Yellow Hose to service port on front of unit. 5. Plug AC Cord to a 115VAC outlet. Turn unit on using the front power switch. 6. Press <AUTO SEQUENCE> and program 10 minute vacuum time by pressing <UP> button twice and then press <HOLD/ENTER/RESTART> 5 times. (This programs 0 for remaining parameters.) 7. Once completed, close Recovery Tank valve (BLUE) and remove Yellow Hose from Recovery Tank. 8. Re-OIL seal on Yellow Hose and connect to center port on Gauge Set. 9. Place Recovery Tank on scale. Tank fittings should face straight out the back of unit. Connect velcro strap and tighten belt. 10. Remove bubble wrap from Red and Blue Hoses from unit. 11. OIL seals on the anti-blow back valves on Red and Blue Hoses from unit. Connect respectively to Recovery Tank. PARAMETER SETUP:! CAUTION! THIS UNIT MUST BE PLUGGED IN TO A PROPER AC OUTLET FOR UNIT TO OPERATE CORRECTLY. REFER TO UNIT ID PLATE LOCATED ON BACK OF UNIT. EXTENSION CORDS ARE NOT RECOMMENDED, BUT IF AN EXTENSION CORD MUST BE USED, USE A CORD THAT IS LESS THAN 50 FEET WITH A 16 AWG, OR ABOVE 50 FEET AND LESS THAN 100 FEET WITH A 14 AWG. 1. Press <AMOUNT> twice to display amount of refrigerant in Recovery Tank. If amount is more than 3 ounces in a empty tank, perform sequence A through C: A. Press <HOLD/ENTER/RESTART> and <AMOUNT> at the same time while the amount of refrigerant is being displayed. B. Press <UP> or <DOWN> to change the amount of refrigerant to 1oz. or toggles between 0 and 1 oz. C. Press <HOLD/ENTER/RESTART> to return to normal operation. 2. Press and hold <UP> and <DOWN> for 5 seconds. Refrigerant charge type will be displayed. 3. If the display shows the incorrect type of refrigerant that is going to be dedicated for this unit, and/or if the "SUN" icon is displayed, stop and call service. 1-800-CALL-SUN 4. Press <UP> or <DOWN> to change CHARGE parameters to "LbOz", "kg", "Lb", or "Oz". Press <HOLD/ENTER/RESTART> to save the desired CHARGE parameters.

PARAMETER SETUP continue... PAGE 5 OF 6 5. Press <UP> or <DOWN> to change AMOUNT parameters to "LbOz", or "kg". Press <HOLD/ENTER/RESTART> to save the desired AMOUNT parameters. CALIBRATION: 1. Close both valves on Recovery Tank. 2. Press and hold <HOLD/ENTER/RESTART> for 5 seconds until LCD displays "CAL". Tank icon should be flashing. 3. Press <HOLD/ENTER/RESTART> again to start calibration. "In Progress" will be displayed. This will take 2-3 minutes to complete. 4. The temperature will be displayed. Press <HOLD/ENTER/RESTART> twice. CHARGING RECOVERY TANK: NOTE: THIS PROCEDURE IS USED TO SETUP THE UNIT FOR CHARGING. RECOVERY TANK SHOULD HAVE AT LEAST A 25" VACUUM. 1. Be sure Recovery Tank valves are closed. 2. Disconnect the Red and Blue hoses from the Recovery Tank. 3. Disconnect and Re-OIL both seals on Yellow hose. Connect the Yellow Hose with the open end to a Virgin Tank. 4. Connect the other end of Yellow Hose to the Red Valve on the Recovery Tank. 5. Open the Red valve on the Recovery Tank.! WARNING! USE STANDARD REFRIGERANT HANDLING SAFETY PROCEDURES WHEN PERFORMING INSTALLATION ALWAYS WEAR SAFETY GOGGLES, DON'T SPILL OR TOUCH LIQUID REFRIGERANT, AVOID FLAMES, & EXCESSIVE HEAT. USE ONLY IN WELL VENTILATED AREA. 6. Invert the Virgin Tank and open valve. If a Hand Valve is present on the Yellow hose, open to allow the refrigerant to flow. 7. Raise the Virgin Tank to a higher level than the Recovery Tank. Gravity and vacuum will transfer the liquid refrigerant to the Recovery Tank faster than reclaiming it. 8. Press <AMOUNT> twice to display the amount of refrigerant that has been transferred. 9. After the desired amount of refrigerant has been transferred, close valves on Virgin Tank and Recovery Tank. Set Virgin Tank on ground upright. 10. Close Hand Valve on Yellow Hose if present. Disconnect Yellow Hose from Recovery Tank.

PAGE 6 OF 6 CHARGING RECOVERY TANK continue... 11. Re-OIL seals on anti-blow back valves on Red and Blue Hoses from unit and connect respectively to Recovery Tank. Open Recovery Tank valves. 12. Re-OIL seals on Yellow Hose and connect to service port on front of unit. Open Hand Valve on Yellow Hose if present. 13. Press <RECLAIM ONLY>. This will reclaim the refrigerant from hose. (Optional: Opening Virgin Tank valve will reclaim rest of refrigerant.) 14. Once complete, disconnect Yellow Hose from Virgin Tank. 15. Re-OIL seals on Yellow Hose and connect to center port on Gauge Set. INSTALLATION/SETUP COMPLETE Place these Installation Instructions with the Service Manual. REMEMBER TO OIL O-RINGS AND SEALS WHEN ATTACHING HOSES OR FITTINGS