TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems

Similar documents
Photobiological safety of lamps and lamp systems

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements. TÜV Rheinland Shanghai Co., Ltd.

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. FCC MPE REPORT

LUXEON S. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON S Photobiological Safety Report

Test Report. Report No.: AGC SS01. Attestation of Global Compliance (Shenzhen) Co., Ltd.

Model No.: VS806-6N ( ) V~ 50/60Hz LED 6x4W

LUXEON Rebel. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON Rebel Photobiological Safety Report

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

AS/NZS IEC :2014

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

Annex A to joint CELMA / ELC Guide on LED related standards: Photobiological safety of LED lamps and lamp systems

INTERNATIONAL STANDARD

This document is a preview generated by EVS

Report Reference No...:

Laser Use at Subaru Telescope (NAOJ) Laser Safety Policy

Ref No: Date: September 30, 1994 ELECTRICAL AND ELECTRONIC EQUIPMENT NO. 2

TEST REPORT PPP 11023A:2011 Rev. 00 TUV SUD Test report for T8/T5 LED tube Lamp

Laser Safety and Regulations Division of Physics and Applied Physics, School of Physical and Mathematical Sciences Nanyang Technological University

This is a preview - click here to buy the full publication

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

Test Report issued under the responsibility of:

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

Rice University Laser Safety Manual

DUQUESNE UNIVERSITY. Laser Safety Program

American National Standard for Safe Use of Lasers

NEED FOR LASER SAFETY

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

PURPOSE OF THE PROCEDURE

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

Contains Nonbinding Recommendations. Draft Not for Implementation

K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C,

Provläsningsexemplar / Preview TECHNICAL REPORT. Safety of laser products. Part 8: Guidelines for the safe use of medical laser equipment

Amendment to Test Report

TEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans

Test Report Iec En Household And Similar

CALIFORNIA INSTITUTE OF TECHNOLOGY LASER SAFETY MANUAL. January, 1998

ISO INTERNATIONAL STANDARD

PAKISTAN STANDARD LED MODULES FOR GENERAL LIGHTING (SAFETY SPECIFICATIONS) PS: _5211/2017 ICS:

Lasers and Laser Safety

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

ISO 9050 INTERNATIONAL STANDARD

GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD

Test Report. Test Requested : Test for compliance with clauses 8 and 9 of IEC : 1993+A1+A2. Page 1 of 6

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

The George Washington University. Laser Safety Manual

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

LASER SAFETY BARRIER

Northern Illinois University Laser Safety Manual

Dentistry Operating lights

Optics & Radiometry Laboratory

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

Non Ionizing Radiation Audit checklist

ISO INTERNATIONAL STANDARD. Small craft Airborne sound emitted by powered recreational craft Part 1: Pass-by measurement procedures

64 Max IR Thermometer

Downlight ENCORE DL6 15W 2700K

UV Safety Measurements Rationale and Problems

Provläsningsexemplar / Preview TECHNICAL REPORT. Part 3-1: Conformity verification report for IEC :2001 General requirements

ISO INTERNATIONAL STANDARD

Basic Laser Safety Training

Laser Radiation and High Voltage/Electrical Shock. Disclaimer and Limitation of Liability. Shipping Damage. Trademarks

American National Standard

Laser Safety Manual. [Section 2.0] - Procedures: Administration and Evaluation

Optical Measurement Techniques for LED Clusters and LED Safety

Consumer Products Services Germany GmbH Türkheim Germany

INTERNATIONAL STANDARD NORME INTERNATIONALE

INTERNATIONAL STANDARD

Safety of household and similar electrical appliances

PENALTIES. All imported products are required to meet the same standards as domestic goods. National Safety Requirements. Customs Requirements

CONTRACTOR WHS HAZARD STANDARD LASER SAFETY EXTERNAL USE ONLY

Laser Safety. Occupational Health and Safety

NX8601BF-AA. Data Sheet R08DS0109EJ0100 Rev.1.00 Apr 19, 2013 LASER DIODE DESCRIPTION FEATURES

Recommended Work Area Controls

Staying Safely on Target! Laser Safety. Chuck Paulausky, CHMM, LSO

AS/NZS 2: 1067:2003 AS/NZS

Laser Institute of America. Laser Safety Guide. Eleventh Edition Prepared by LIA Laser Safety Committee

USER MANUAL MODEL UV MINDER 3D V2.0. Part Number: Revision Level: A

Laser Safety. This Laser Safety Program applies to the acquisition, use, transfer, and disposal of all Class 3B and 4 lasers at UNC Asheville.

Gas Temperature Measurements with High Temporal Resolution

University of North Florida Laser Safety Manual. Environmental Health and Safety Department

Radiation and Laser Safety

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Report reference No...: 10TH0052_AS4777_+_ISR_3 Tested by (printed name and signature)...: Urs Seifert. Approved by (printed name and signature)...

Equipment specifications (D6)

ISO INTERNATIONAL STANDARD

TEST REPORT EN Alarm Systems Intrusion and Hold-up Systems Part 2-4: Requirements for Combined Passive Infrared and Microwave Detectors

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests

North Dakota State University Laser Safety

BS EN : A2:2015 used in conjunction with BS EN : A11:2014 and BS EN 62233:2008

Page 2 of 14 Report Ref. No

American National Standard

Silicon Pyranometer GSM xx

Laser Safety Products. Edition 20

Xiamen Comfort Science & Technology Group Co., Ltd 18 Long Shan South Road, Xiamen, Fujian Province, , China

Test Report. Test Requested : Test for compliance with clauses 8 and 9 of IEC : 1993+A1+A2. Page 1 of 6

FOCUS ON LASERS. Philip Campbell RADIATION SAFETY: Principles, Practice, and Emerging Issues March 2018

Procedure for the Approval of New Fire Detection and Alarm Technologies

Transcription:

Test Report issued under the responsibility of: TEST REORT IEC 62471 and/or EN 62471 hotobiological safety of lamps and lamp systems Report Reference No.... : GZES130300236831 Tested by (name + signature)... : TimDing... Approved by (name + signature)... : AnnaYu... Date of issue... : 2013-04-26 Total number of pages... : 14 Testing Laboratory... : Address... : Applicant s name... : Address... : SGS-CSTC Standards Technical Services Co., Ltd. - E&E Lab Guangzhou 198 Kezhu Road, Scientech ark, Guangzhou Economic & Technology Development District, Guangzhou, 510663 Guangdong, China Test specification: Standard... : Test procedure... : Non-standard test method..: IEC 62471: 2006 (First Edition) EN 62471:2008 Test report Test Report Form No.... : IECEN62471A (Modified by SGS-CSTC, dated 2012-5, added content of EN 62471: 2008) TRF Originator... : VDE Testing and Certification Institute Master TRF... : Dated 2009-05 Copyright 2009 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongastheIECEEisacknowledgedascopyright ownerandsourceofthematerial.ieceetakesnoresponsibilityforandwillnotassumeliabilityfordamagesresultingfromthereader's interpretation of the reproduced material due to its placement andcontext. Test item description... : Trade Mark... : -- Manufacturer... : LED Same as applicant Model/Type reference... : 5W2HC, 5W4HC, 47W2HC, 47W4HC, 3W2HC, 3W4HC, 8W2HC, 8W4HC, 10W2HC, 10W4HC Ratings... : 3,0-3,4 Vd.c., 20 ma

age 2 of 14 Summary of testing: These tests fulfil the requirements of standard ISO/IEC 17025. Due to the physical properties of the Lamp, this product does not contain any radiation above 800nm. Therefore the measured spectral range has been limited from 200nm up to and including 800nm. After review, model 3W2HC was selected for test as respective. The tests were conducted under 20 ma powered by DC source. The submitted samples were found to be in compliance with EN 62471: 2008. Tests performed (name of test and test clause): 4.3.1 Actinic UV hazard exposure limit for the skinand eye 4.3.2 Near-UV hazard exposure limit foreye 4.3.3 Retinal blue light hazard exposurelimit 4.3.5 Retinal thermal hazard exposure limit Testing location: Refer to page 1. Summary of compliance with National Differences: Compliance with the National requirements of EUROEAN GROU DIFFERENCES AND NATIONAL DIFFERENCES for EN 62471: 2008. Copy of marking plate:

age 3 of 14 Test item particulars...: Tested lamp...: continuouswavelamps pulsedlamps Tested lamp system...: Lamp classificationgroup...: exempt risk1 risk2...:-- Bulb...: -- Rated of the lamp...: -- Furthermore marking on the lamp...: -- Seasoning of lamps according IEC standard...: -- risk3lamp cap Used measurement instrument...: Ref. to List of test equipment used Temperature by measurement...: 25 ± 5 o C ossible test case verdicts: test case does not apply to the test object... : test object does meet the requirement... : (ass) test object does not meet the requirement... : F(Fail) Testing: Date of receipt of test item... : 2013-04-02 Date (s) of performance of tests... : 2013-04-02 to 2013-04-26 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma is used as the decimal separator. List of test equipment must be kept on file and available for review. When determining for test conclusion, measurement uncertainty of tests has been considered. This document is issued by the Company subject to its General Conditions of Service, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company s findings at the time of its intervention only and within the limits of Client s instructions, if any. The Company s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be produced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.

age 4 of 14 General product information: The product can emit cool white light when powered. Deviation between models: Models 5W2HC, 5W4HC, 47W2HC, 47W4HC, 3W2HC, 3W4HC, 8W2HC, 8W4HC, 10W2HC and 10W4HC are identical in electrical and mechanical construction except for the different diameter of the colloidal substance and the length of the pins.(diameter of the colloidal is 5 mm for model 5W2HC, 5W4HC; 4,7 mm for model47w2hc,47w4hc;3mmformodel3w2hc,3w4hc;8mmformodel8w2hc,8w4hc;10mmfor model 10W2HC,10W4HC)

age 5 of 14 IEC 62471 4 EXOSURE LIMITS -- 4.1 General The exposure limits in this standard is not less than 0,01 ms and not more than any 8-hour period and should be used as guides in the control of exposure Detailed spectral data of a light source are generally required only if the luminance of the source exceeds 10 4 cd. m -2 see clause 4.3 4.3 Hazard exposure limits 4.3.1 Actinic UV hazard exposure limit for the skin and eye The exposure limit for effective radiant exposure is 30 J. m -2 within any 8-hour period To protect against injury of the eye or skin from ultraviolet radiation exposure produced by a broadband source, the effective integrated spectral irradiance, E S, of the light source shall not exceed the levels defined by: The permissible time for exposure to ultraviolet radiation incident upon the unprotected eye or skin shall be computed by: 4.3.2 Near-UV hazard exposure limit for eye Forthespectralregion315nmto400nm(UV-A)the total radiant exposure to the eye shall not exceed 10000 J. m -2 for exposure times less than 1000 s.for exposure times greater than 1000 s (approximately 16 minutes) the UV-A irradiance for the unprotected eye, E UVA, shall not exceed 10 W. m -2. The permissible time for exposure to ultraviolet radiation incident upon the unprotected eye for time less than 1000 s, shall be computed by: 4.3.3 Retinal blue light hazard exposure limit To protect against retinal photochemical injury from chronic blue-light exposure, the integrated spectral radiance of the light source weighted against the blue-light hazard function, B(λ), i.e., the blue-light weighted radiance, L B, shall not exceed the levels defined by: see table 4.2

age 6 of 14 IEC 62471 for t 10 4 s 4.3.4 Retinal blue light hazard exposure limit - small source Thus the spectral irradiance at the eye E λ, weighted against the blue-light hazard function B(λ) shall not exceed the levels defined by: 4.3.5 Retinal thermal hazard exposure limit To protect against retinal thermal injury, the integrated spectral radiance of the light source, L λ, weighted by the burn hazard weighting function R( λ) (from Figure 4.2 and Table 4.2), i.e., the burn hazard weighted radiance, shall not exceed the levels defined by: (10 μs t 10 s) 4.3.6 Retinal thermal hazard exposure limit weak visual stimulus Foraninfraredheatlamporanynear-infraredsource where a weak visual stimulus is inadequate to activate the aversion response, the near infrared (780 nm to 1400 nm) radiance, L IR, as viewed by the eye for exposure times greater than 10 s shall be limited to: 4.3.7 Infrared radiation hazard exposure limits for the eye The avoid thermal injury of the cornea and possible delayed effects upon the lens of the eye (cataractogenesis), ocular exposure to infrared radiation, E IR, over the wavelength range 780 nm to 3000 nm, for times less than 1000 s, shall not exceed: For times greater than 1000 s the limit becomes:

age 7 of 14 IEC 62471 4.3.8 Thermal hazard exposure limit for the skin Visible and infrared radiant exposure (380 nm to 3000 nm) of the skin shall be limited to: 5 MEASUREMENT OF LAMS AND LAM SYSTEMS -- 5.1 Measurement conditions Measurement conditions shall be reported as part of the evaluation against the exposure limits and the assignment of risk classification. 5.1.1 Lamp ageing (seasoning) Seasoning of lamps shall be done as stated in the appropriate IEC lamp standard. 5.1.2 Test environment For specific test conditions, see the appropriate IEC lamp standard or in absence of such standards, the appropriate national standards or manufacturer s recommendations. 5.1.3 Extraneous radiation Careful checks should be made to ensure that extraneous sources of radiation and reflections do not add significantly to the measurement results. 5.1.4 Lamp operation Operation of the test lamp shall be provided in accordance with: the appropriate IEC lamp standard,or the manufacturer srecommendation 5.1.5 Lamp system operation The power source for operation of the test lamp shall be provided in accordance with: the appropriate IEC standard,or the manufacturer srecommendation 5.2 Measurement procedure 5.2.1 Irradiance measurements Minimum aperture diameter 7mm. Maximum aperture diameter 50 mm.

age 8 of 14 IEC 62471 The measurement shall be made in that position of the beam giving the maximum reading. The measurement instrument is adequate calibrated. 5.2.2 Radiance measurements 5.2.2.1 Standard method The measurements made with an optical system. The instrument shall be calibrated to read in absolute radiant power per unit receiving area and per unit solid angle to acceptance averaged over the field of view of the instrument. 5.2.2.2 Alternative method Alternatively to an imaging radiance set-up, an irradiance measurement set-up with a circular field stop placed at the source can be used to perform radiance measurements. 5.2.3 Measurement of source size The determination of α, the angle subtended by a source, requires the determination of the 50% emission points of the source. 5.2.4 ulse width measurement for pulsed sources The determination of t, the nominal pulse duration of a source, requires the determination of the time duringwhichtheemissionis>50%ofitspeakvalue. 5.3 Analysis methods 5.3.1 Weighting curve interpolations To standardize interpolated values, use linear interpolation on the log of given values to obtainintermediate points at the wavelength intervals desired. see table 4.1 5.3.2 Calculations The calculation of source hazard values shall be performed by weighting the spectral scan by the appropriate function and calculating the total weighted energy. 5.3.3 Measurement uncertainty The quality of all measurement results must be quantified by an analysis of the uncertainty. see Annex C in the norm 6 LAM CLASSIFICATION -- For the purposes of this standard it was decided that the values shall be reported as follows: see IEC 62471 table 6.1

age 9 of 14 IEC 62471 for lamps intended for generallightingservice,the hazard values shall be reported as either ir- radiance or radiance values at a distance which producesanilluminanceof500lux,butnotata distance less than 200 mm for all other light sources, includingpulsedlampsources, the hazard values shall be reported ata distance of 200mm r = 200 mm 6.1 Continuous wave lamps 6.1.1 Exempt Group In the exempt group are lamps, which do not pose any photobiological hazard. The requirement is met by any lamp that does not pose: an actinic ultraviolet hazard (E S)within8- hoursexposure (30000 s),nor anear- UVhazard(E UVA)within1000s,(about16min),nor a retinal blue-light hazard (L B) within 10000 s(about 2,8 h),nor a retinal thermal hazard (L R) within 10 s,nor an infrared radiation hazard for theeye(e IR)within 1000s 6.1.2 Risk Group 1 (Low-Risk) In this group are lamps, which exceeds the limits for the exempt group but that does not pose: an actinic ultraviolet hazard (E S) within10000 s,nor a near ultraviolet hazard (E UVA) within 300 s,nor a retinal blue-light hazard (L B) within 100 s,nor a retinal thermal hazard (L R) within 10 s,nor an infrared radiation hazard for theeye(e IR)within 100s Lamps that emit infrared radiation without a strong visual stimulus and do not pose a near-infrared retinal hazard (L IR), within 100 s are in Risk Group 1. 6.1.3 Risk Group 2 (Moderate-Risk) This requirement is met by any lamp that exceeds the limits for Risk Group 1, but that does not pose: an actinic ultraviolet hazard (E S) within1000sexposure,nor a near ultraviolet hazard (E UVA) within 100 s,nor

age 10 of 14 IEC 62471 a retinal blue-light hazard (L B) within0,25s(aversion response),nor a retinal thermal hazard (L R) within 0,25 s(aversion response),nor an infrared radiation hazard for theeye(e IR)within 10s Lamps that emit infrared radiation without a strong visual stimulus and do not pose a near-infrared retinal hazard (L IR), within 10 s are in Risk Group 2. 6.1.4 Risk Group 3 (High-Risk) Lamps which exceed the limits for Risk Group 2 are in Group 3. 6.2 ulsed lamps

age 11 of 14 EN 62471 Clause Requirement + Test Result - Remark Verdict CENELEC COMMON MODIFICATIONS (EN) -- 4 EXOSURE LIMITS -- Contents of the whole Clause 4 of IEC 62471:2006 moved into a new informative Annex ZB Clause 4 replaced by the following: Limits of the Artificial Optical Radiation Directive (2006/25/EC) have been applied instead of those fixed in IEC 62471:2006 See EN 62471 table 6.1 4.1 General First paragraph deleted

age 12 of 14 IEC 62471 Table 6.1 Emission limits for risk groups of continuous wave lamps Risk Action spectrum Symbol Units Emission Measurement Exempt Low risk Mod risk Limit Result Limit Result Limit Result Actinic UV S UV(λ) E s W m -2 0,001 -- 0,003 -- 0,03 -- Near UV -- E UVA W m -2 10 -- 33 -- 100 -- Blue light B(λ) L B W m -2 sr -1 100 -- 10000 -- 4000000 -- Blue light, small source Retinal thermal Retinal thermal, weak visual stimulus** IR radiation, eye B(λ) E B W m -2 1,0* -- 1,0 -- 400 -- R(λ) L R W m -2 sr -1 28000/α -- 28000/α -- 71000/α -- R(λ) L IR W m -2 sr -1 6000/α -- 6000/α -- 6000/α -- -- E IR W m -2 100 -- 570 -- 3200 -- * Smallsourcedefinedasonewithα<0,011radian.Averagingfieldofviewat10000sis0,1radian. ** Involves evaluation of non-gls source

age 13 of 14 EN 62471 Table 6.1 Emission limits for risk groups of continuous wave lamps (based on EU Directive 2006/25/EC) Risk Action spectrum Symbol Units Emission Measurement Exempt Low risk Mod risk Limit Result Limit Result Limit Result Actinic UV S UV(λ) E s W m -2 0,001 0 - - - - Near UV -- E UVA W m -2 0,33 0 - - - - Blue light B(λ) L B W m -2 sr -1 100 62,4 10000 -- 4000000 -- Blue light, small source Retinal thermal Retinal thermal, weak visual stimulus** IR radiation, eye B(λ) E B W m -2 0,01* -- 1,0 -- 400 -- R(λ) L R W m -2 sr -1 28000/α 58925,6 28000/α -- 71000/α -- R(λ) L IR W m -2 sr -1 545000 0,0017 α 0,011 6000/α 0,011 α 0,1 -- E IR W m -2 100 -- 570 -- 3200 -- * Smallsourcedefinedasonewithα<0,011radian.Averagingfieldofviewat10000sis0,1radian. ** Involves evaluation of non-gls source -- --

age 14of14 Report No.:GZES130300236831 hoto documentation Detailsof: View for theproduct View: [ x ] general [ ]front [ ] rear [ ] right [ ]left [ ]top [ ]bottom [ ]Internal End of report