Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS

Similar documents
Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS.

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

R4H4. Product Specifications

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

R4H4. Product Specifications

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5

563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES

Product Data PA13NA PA13PA FEATURES AND BENEFITS

PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling

N4H4. Product Specifications

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

A 14 SEER Heat Pump with R---410A Refrigerant Series

597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8

WCH5**4. Product Specifications

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS

N4A6. Product Specifications

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060

661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES

Product Data. Efficiency

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons

Product Data. Efficiency. S S Reliability

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4

Product Data. Efficiency

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES

697C (60 HZ) Sizes 018 thru 060

Product Data. Efficiency

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES

INDUSTRY LEADING FEATURES 2 5 / BENEFITS

Product Data. Efficiency

R 410A Ducted Horizontal Air Conditioner

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38EYA (60Hz) 12 SEER Split-System Cube Heat Pump with Puron Refrigerant FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

HEATING & COOLING 38YCA Sizes 018 thru YCN Sizes 024 thru 048. Copyright 1994 Carrier Corporation

Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Advance Product Data

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

PAJ3. Product Specifications

650A (60 Hz) QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 650A.24.1

Product Data. Efficiency

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Product Data. Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 018 thru 060

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Advance Product Data

WJH4 Product Specifications

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Installation Instructions

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Advance Product Data

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3

PAR5. Product Specifications

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Product Data. 24ACB7 Performancet 2---Stage Air Conditioner with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS

Transcription:

Product Data 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS Sizes 018 thru 060 The 38CKS Air Conditioner is designed for superior performance durability in harsh environments. The product achieves up to 9.8 EER ratings when used with manufacturer specified components. The product is available in seven standard nominal sizes ranging from 018 to 060 for residential and light commercial applications. All models are listed with UL (U.S. and Canada). AVAILABLE OPTIONS ArmorPlate Condenser Coil The outdoor coil lasts three times longer than other standard condenser coils by utilizing a special ArmorPlate protective coating on the coil. Heavy Duty Inlet Grille The WeatherArmor coil protector, made of a coated steel wire grid with vertical 3/8 in. (9.5 mm) spacing, is designed to help protect the coil from inclement weather, vandalism, and incidental damage. It provides protection while not restricting airflow and maintaining ease of coil inspection and cleaning. Cabinet Protection Provides superior durability through added paint coverage on all sheet metal components. The cabinet is constructed with galvanized, prepainted steel, providing each unit with a finish that will last for many years. Additional attention to detail, such as the motor cap, protects the fan motor from exposure to the elements. Coil isolators protect the unit from internal scratches during installation and shipping. All screws on cabinet exterior are coated for a long-lasting rust-resistance. Copyright 2005 Carrier Corporation Form 38CKS-5PD

Money Saving Operation Investment protection through long lasting components in harsh conditions. Electrical Range All model sizes are offered in single phase 208-230 volt. Unit Design Copper tube, wavy aluminum fin coil is designed for optimum heat transfer. Vertical air discharge carries sound and hot condenser air up and away from adjacent patio areas and foliage. Heat pump style drain pan allows for easy removal of water, dirt, and debris. ally Enclosed Fan Motor Provides greater reliability under adverse conditions and dependable performance for many years. The permanent split-capacitor type motor was designed for optimum efficiency. Then, under extreme conditions, the motor was tested and qualified to help ensure the greatest reliability. External Service Valves Both brass service valves are front seating, with provision for field sweat connections. Valves are externally located for quick and easy refrigerant tube connections. Each valve provides service ports for ease in checking operating refrigerant pressures. Easy Serviceability One access panel provides access to electrical controls and compressor. Removal of wire dome gives access to fan motor and removal of the top gives access to the coil. Compressor Protection Each compressor is protected with internal temperature and current sensitive overloads. Operating Range Minimum outdoor operating ambient in cooling mode is 55ºF (12.8ºC), maximum is 125ºF (51.7ºC). ISO 9001:2000 REGISTERED Model number nomenclature 38CKS 018 3 A 1 10 SEER Coastal Air Conditioner Packaging Nominal 018 18,000 Btuh 042 42,000 Btuh 024 24,000 Btuh 048 48,000 Btuh 030 30,000 Btuh 060 60,000 Btuh 036 36,000 Btuh Electrical 3 208-230-1 Series The data in this publication is displayed for all series; however, every series may not be available from manufacturer. 2

Physical data UNIT SIZE 018-3A 024-3A 030-3A 036-3A 042-3A 048-3A 060-3A OPERATING WT (Lb/Kg) 115/52.3 117/53.2 133/60.5 138/62.7 142/64.5 198/90.0 218/99.1 COMPRESSOR Type Reciprocating Scroll REFRIGERANT Control Charge (Lb/Kg) @ 15 Ft (4.6 m) COND FAN Air Discharge Air Qty (CFM/L/S) Motor HP Motor RPM COND COIL Face Area (Sq Ft/m 2 ) Fins per In./Fins per cm Rows Circuits VALVE CONNECTION (In./mm ID) Vapor Liquid R22 AccuRater (Bypass Type) 3.30/1.5 3.65/1.66 4.25/1.93 4.60/2.09 5.13/2.33 6.38/2.90 8.46/3.85 Propeller Type, Direct Drive Vertical 1500/708 1700/802 2000/944 2500/1180 3400/1605 1/8 1/12 1/10 1/5 1/4 1500 1125 1125 1125 1125 Copper Tube, Aluminum Plate Fin 6.8/.63 9.1/.85 9.9/.92 12.4/1.15 14.8/1.37 18.5/1.72 16.1/1.50 20/8 20/8 20/8 20/8 20/8 20/8 20/8 1 1 1 1 1 1 2 1 2 2 2 3 3 4 Sweat 5/8/15.88 5/8/15.88 3/4/19.05 3/4/19.05 7/8/22.23 3/8/9.53 REFRIG TUBES* (In./mm OD) Vapor (0 50 Ft/0-15.24m Tube Length) 5/8/15.88 3/4/19.05 7/8/22.23 1-1/8/28.58 Vapor (Max Diameter for Long-Line Applications) 3/4/19.05 7/8/22.23 1-1/8/28.58 1-1/8/28.58 Liquid (0 50/0-15.24m Ft Tube Length) 3/8/9.53 Liquid (For Long-Line Applications) 3/8/9.53 * For tubing sets between 50 (15.24m) and 175 ft (53.34m) horizontal and/or 20 ft (6.1m) vertical differential, consult Residential Split tems Long- Line Application Guideline. NOTE: See unit Installation Instructions for proper installation. METERING DEVICE PISTON UNIT SIZE AND SERIES IDENTIFICATION NO. 018-3A 52 024-3A 59 030-3A 67 036-3A 73 042-3A 82 048-3A 82 060-3A 90 * Piston listed is for any approved non-capillary tube coil combination. Piston is shipped with outdoor unit and must be installed in an approved indoor coil. A-weighted sound power (dba) UNIT STANDARD TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) (Hz) SIZE RATING 125 250 500 1000 2000 4000 8000 018-3A 80 57.5 64.0 69.5 72.0 71.5 68.0 60.0 024-3A 80 55.5 63.0 68.0 71.0 70.5 67.5 58.5 030-3A 80 54.0 68.5 72.5 73.0 70.5 67.0 61.5 036-3A 82 56.5 70.0 73.5 75.5 74.5 71.0 65.0 042-3A 82 59.0 66.5 68.5 75.5 71.5 73.0 65.5 048-3A 82 58.5 72.5 74.0 77.0 72.5 70.0 65.0 060-3A 82 57.5 68.0 69.0 72.5 70.5 71.0 70.0 3

Accessories PART NO. DESCRIPTION KAATD0101TDR Time-Delay Relay All Sizes KSALA0201R22 Low Ambient Pressure Switch Kit All Sizes KSALA0401AAA* MotorMaster Low-Ambient Controller Sizes 024 060 N/A MotorMaster Low-Ambient Controller Size 018 N/A Ball Bearing Fan Motor Size 018 HC34GE232(RCD) Ball Bearing Fan Motor Sizes 024, 030 HC40GE232(RCD) Ball Bearing Fan Motor Sizes 036 060 KAAFT0101AAA Evaporator Freeze Thermostat All Sizes KAAWS0101AAA Winter Start Control All Sizes KSACY0101AAA Cycle Protector Sizes 018 060 KSAHS0901AAA Start Assist Capacitor and Relay Sizes 018 030 KSAHS1101AAA Start Assist Capacitor and Relay Size 036 KSAHS1301AAA Start Assist Capacitor and Relay Size 042 KSAHS1601AAA Start Assist Capacitor and Relay Sizes 048, 060 KAACS0201PTC Start Assist PTC All Sizes KAACH1001AAA Crankcase Heater Sizes 018 042 KAACH1201AAA Crankcase Heater Sizes 048, 060 N/A Sound Hood Sizes 018 030 KSASH2001BRL Sound Hood Size 036 KSASH1201COP Sound Hood Size 042 KSASH2001CYL Sound Hood Sizes 048, 060 KAATX0201RPB Thermostatic Expansion Valve (RPB) Size 018 KAATX0301RPB Thermostatic Expansion Valve (RPB) Size 024 KAATX0401RPB Thermostatic Expansion Valve (RPB) Size 030 KAATX0501RPB Thermostatic Expansion Valve (RPB) Sizes 036, 042 KAATX0601RPB Thermostatic Expansion Valve (RPB) Size 048 KAATX0701RPB Thermostatic Expansion Valve (RPB) Size 060 KSATX0601HSO Thermostatic Expansion Valve (Hard Shutoff) Sizes 018 042 KSATX0701HSO Thermostatic Expansion Valve (Hard Shutoff) Size 048 KSATX1001HSO Thermostatic Expansion Valve (Hard Shutoff) Size 060 KAALP0101LPS Low-Pressure Switch All Sizes KSAHI0101HPS High-Pressure Switch All Sizes P502-8083S (RCD) Filter Drier Sizes 018 036 P502-8163S (RCD) Filter Drier Sizes 042 060 KAALS0101LLS Liquid-Line Solenoid Valve All Sizes * Fan motor with ball bearings required. Start assist capacitor and relay required when using liquid solenoid valve or hard shutoff TXV (except 048 and 060 sizes). Do not use hard shutoff TXV with liquid solenoid valve. N/A Not Applicable 4

THERMOSTAT PKG. TSTATCCPRH01-B TSTATCCPAC01-B TSTATCCNAC01-C TSTATCCBAC01-B TSTATXXSEN01-B TSTATXXNBP01 TSTATXXPBP01 TSTATXXBBP01 TSTATXXCNV10 DESCRIPTION Thermidistat Control, Programmable/Non-Programmable Thermostat with Humidity Control Thermostat, Auto Changeover, 7-Day Programmable, F/ C, 1-Stage Heat, 1-Stage Cool Thermostat, Auto Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool Builder s Thermostat, Manual Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool Outdoor Air Temperature Sensor Backplate for Non-Programmable Thermostat Backplate for Programmable Thermostat Backplate for Builder s Thermostat Thermostat Conversion Kit (4 to 5 wire) 10 Pack Accessory usage guideline ACCESSORY REQUIRED FOR LOW-AMBIENT APPLICATIONS (Below 55 F) REQUIRED FOR LONG-LINE APPLICATIONS* (Over 50 Ft) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 Miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Winter Start Control Yes No No Accumulator No No No Compressor Start Assist Capacitor and Relay Yes Yes No MotorMaster Low-Ambient Controller or Low-Ambient Pressure Switch Yes No No Wind Baffle See Low-Ambient Instructions No No Coastal Filter No No No Liquid-Line Solenoid Valve or Hard Shutoff TXV No See Long-Line Application Guideline No Ball Bearing Fan Motor Yes No No * For tubing line sets between 50 (15.24m) and 175 ft (53.34m) and/or 20 ft (6.1m) vertical differential, refer to Residential Split tems Long-Line Application Guideline. Only when low-pressure switch is used. Required for Low-Ambient Controller MotorMaster Control only. Accessory description and usage (Listed alphabetically) 1. Ball-Bearing Fan Motor A fan motor with ball bearings, which permits speed reduction while maintaining bearing lubrication. Required on all units when MotorMaster Low-Ambient Controller is installed. 2. Coastal Filter A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow. 3. Compressor Start Assist Capacitor and Relay Start capacitor and relay gives a "hard" boost to compressor motor at each start up. Required for reciprocating compressors in the following applications: Long line Low ambient Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil Required for scroll compressors in the following applications: Long line Low ambient Suggested for all compressors in areas with a history of low voltage problems. 4. Compressor Start Assist PTC Type Solid-state electrical device which gives a "soft" boost to the compressor motor at each start up. Suggested when compressor power supply is marginal Suggested in reciprocating compressor applications with rapid pressure balance (RPB) expansion valve on indoor coil. 5

Accessory description and usage (continued) 5. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Required in low ambient applications. Required in long line applications. Suggested in all commercial applications. 6. Evaporator Freeze Thermostat An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions. Required when low ambient kit has been added. 7. Filter Drier Bi-Flow A device for removing contaminants from refrigerant circulating in an air conditioning system: single-direction flow. Suggested in all field-connected split-system air conditioners. 8. High-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to 426 ± 10 psig and resets at 320 ± 20 psig. Provides protection against compressor damage due to loss of outdoor airflow. Suggested in installations exposed to "very dirty" outdoor air. Suggested in installations where condenser inlet air temperature exceeds 125 F. (51.7 C) 9. Liquid-Line Solenoid Valve (LLS) This device serves two purposes. It is an electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It maintains a column of refrigerant liquid ready for action at next compressor operation cycle. It also provides system protection against off-cycle refrigerant migration. NOTE: When LLS is used with reciprocating compressors, Compressor Start Assist Capacitor and Relay is required. Required in air conditioner long line applications with a piston indoor metering device to prevent off cycle refrigerant migration. A hard shut off TXV can be used instead of LLS in single flow air conditioner applications. See Long Line Application Guideline. 10. Low-Ambient Pressure Switch A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low-ambient temperatures down to 0 F ( 17.8 C) when properly installed. A Low-Ambient Pressure Switch or Motor Master Low-Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55 F (12.8 C). 11. MotorMaster -Low-Ambient Controller A fan speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to 20 F ( 28.9 C), it maintains condensing temperature at 100 F ± 10 F (37.8 C ± 12 C). A Motor Master Low-Ambient Controller or Low-Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55 F (12.8 C). Suggested for all commercial applications. 12. Outdoor Air Temperature Sensor Designed for use with Carrier Thermostats listed in this publication. The device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Suggested for all Carrier thermostats listed in this publication. 13. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dba. Suggested when unit is installed closer than 15 ft to quiet areas bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft apart. 14. Thermostatic Expansion Valve (TXV) Single-Flow A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shutoff and RPB valves are available. NOTE: When using a hard shut off TXV with single phase reciprocating compressors, a Compressor Start Assist Capacitor and Relay is required. Required to achieve ARI ratings in certain equipment combinations. Refer to combination ratings. Hard shut off TXV or LLS required in air conditioner long line applications. Required for use on all zoning systems. 15. Time-Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below. For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. 6

Electrical data UNIT SIZE-SERIES V/PH OPER VOLTS* COMPRESSOR Max Min LRA RLA FAN FLA 018-3A 48.0 9.0 0.8 12.1 14 14 65 61 20 024-3A 61.0 12.2 0.5 15.8 14 14 49 47 20 030-3A 73.0 14.0 0.8 18.4 14 14 40 38 25 036-3A 208-230-1 253 197 86.0 17.7 1.4 23.5 12 12 58 55 35 042-3A 102.0 19.7 1.4 26.0 10 10 75 70 40 048-3A 140.0 24.4 1.4 31.9 8 10 95 55 50 060-3A 165.0 28.9 1.4 37.5 8 8 80 75 60 * Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure. If wire is applied at ambient greater than 30 C (86 F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. If other than uncoated (non-plated), 60 or 75 C (140 or 167 F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). Length shown is as measured 1 way along wire path between the unit and service panel for a voltage drop not to exceed 2%. ** Time-delay fuse. FLA Full Load Amps LRA Locked Rotor Amps MCA Minimum Circuit Amps RLA Rated Load Amps NOTES: 1. Control circuit is 24v on all units and requires external power source. 2. Copper wire must be used from service disconnect to unit. 3. All motors/compressors contain internal overload protection. MCA 60 C MIN WIRE SIZE 75 C MIN WIRE SIZE 60 C MAX LENGTH (Ft) 75 C MAX LENGTH (Ft) MAX FUSE** OR CKT BKR AMPS 7

Dimensions 38CKS AIR DISCHARGE M AIR IN A SQ AIR DISCHARGE AIR IN 3/8 -IN. DIA (9.5mm) TIEDOWN KNOCKOUTS (2) PLACES N J K L AIR IN B P FIELD POWER SUPPLY CONN 7 /8 -IN. (22.2 mm) DIA HOLE WITH 1 1 /8 -IN. DIA (28.6 mm) KNOCKOUT AND 1 3 /8 -IN. (34.9 mm) DIA KNOCKOUT FIELD CONTROL SUPPLY CONN 7 /8 -IN. (22.2 mm) DIA HOLE 3/8 -IN. (9.5mm) DIA LIQUID LINE CONN 2 7 /8 (73.0 mm) C AIR DISCHARGE E AIR IN D DIA VAPOR LINE CONN 1 1 /4 (31.6 mm) G F H NOTES: 1. ALLOW 30 (762.0mm) CLEARANCE TO SERVICE SIDE OF UNIT, 48 (1219.2mm) ABOVE UNIT, 6 (152.4mm) ON ONE SIDE, 12 (308.8mm) ON REMAINING SIDE, AND 24 (609.6mm) BETWEEN UNITS FOR PROPER AIRFLOW. 2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING MODE IS 55 F (12.8 C) MAX 125 F (51.7 C). 3. SERIES DESIGNATION IS THE 13TH POSITION OF THE UNIT MODEL NUMBER. 4. CENTER OF GRAVITY. S.I. A05102 UNIT DIMENSIONS (MM) MINIMUM UNIT MOUNTING PAD SIZE SERIES A B C D E F G H J K L M N P DIMENSIONS 018 A 457.2 658.81 81.0 15.9 76.2 381.0 414.3 450.9 258.8 409.6 450.9 200.0 212.7 257.2 457.2 X 457.2 024 A 571.5 658.81 81.0 15.9 93.7 460.4 501.7 565.2 365.1 496.9 560.4 260.4 241.3 285.8 571.5 X 571.5 030 A 571.5 709.61 81.0 19.1 93.7 460.4 501.7 565.2 365.1 496.9 560.4 260.4 241.3 298.5 571.5 X 571.5 036 A 571.5 862.01 81.0 19.1 93.7 460.4 501.7 565.2 365.1 496.9 560.4 260.4 241.3 393.7 571.5 X 571.5 042 A 762.0 709.61 82.6 22.2 165.1 596.9 692.2 755.7 508.0 687.4 750.9 393.7 355.6 393.7 762.0 X 762.0 048 A 762.0 862.01 82.6 22.2 165.1 596.9 692.2 755.7 508.0 687.4 750.9 393.7 355.6 393.7 762.0 X 762.0 060 A 762.0 760.41 82.6 22.2 165.1 596.9 692.2 755.7 508.0 687.4 750.9 393.7 355.6 381.0 762.0 X 762.0 ENGLISH UNIT DIMENSIONS (IN.) MINIMUM UNIT MOUNTING PAD SIZE SERIES A B C D E F G H J K L M N P DIMENSIONS 018 A 18 25-15/16 3-3/16 5/8 3 15 16-5/6 17-3/4 10-3/16 16-1/8 17-3/4 7-7/8 8-3/8 10-1/8 18 X 18 024 A 22-1/2 25-15/16 3-3/16 5/8 3-11/16 18-1/8 19-3/4 22-1/4 14-3/8 19-9/16 22-1/16 10-1/4 9-1/2 11-1/4 22-1/2 X 22-1/2 030 A 22-1/2 27-15/16 3-3/16 3/4 3-11/16 18-1/8 19-3/4 22-1/4 14-3/8 19-9/16 22-1/16 10-1/4 9-1/2 11-3/4 22-1/2 X 22-1/2 036 A 22-1/2 33-15/16 3-3/16 3/4 3-11/16 18-1/8 19-3/4 22-1/4 14-3/8 19-9/16 22-1/16 10-1/4 9-1/2 15-1/2 22-1/2 X 22-1/2 042 A 30 27-15/16 3-1/4 7/8 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 15-1/2 14 15-1/2 30 X 30 048 A 30 33-15/16 3-1/4 7/8 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 15-1/2 14 15-1/2 30 X 30 060 A 30 29-15/16 3-1/4 7/8 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 15-1/2 14 15 30 X 30 8

Combination ratings* UNIT SIZE-SERIES 018-3A 024-3A 030-3A 036-3A 042-3A 048-3A 060-3A INDOOR UNIT COOLING CAPACITY @ 95 F (35 C) COOLING CAPACITY @ 115 F (46 C) NOMINAL AIRFLOW RATED CAPACITY POWER RATED RATED CAPACITY POWER CFM L/S BTUH EER BTUH FB4BNF018 600 280 17,000 4.98 1.81 9.40 14,000 4.10 2.06 FB4BNF024 600 280 17,600 5.16 1.83 9.60 15,000 4.39 2.14 FA4CN(F,C)018 600 280 17,600 5.16 1.83 9.60 15,500 4.54 2.21 FA4CN(F,C)024 600 280 17,800 5.22 1.84 9.70 15,500 4.54 2.21 FB4BNF024 800 380 23,200 6.80 2.39 9.70 18,700 5.48 2.75 FB4BNF030 800 380 23,500 6.89 2.40 9.80 19,000 5.57 2.71 FA4CN(F,C)024 800 380 23,500 6.89 2.40 9.80 19,500 5.71 2.79 FA4CN(F,C)030 800 380 23,800 6.97 2.43 9.80 19,500 5.71 2.79 FB4BNF030 1000 467 28,600 8.38 3.04 9.40 23,200 6.80 3.41 FB4BNF036 1000 467 28,800 8.44 3.06 9.40 23,500 6.89 3.36 FA4CN(F,C)030 1000 467 29,000 8.50 3.05 9.50 23,800 6.97 3.40 FA4CN(F,C)036 1000 467 29,200 8.56 3.07 9.50 24,000 7.03 3.43 FB4BNF036 1200 550 33,500 9.82 3.72 9.00 27,800 8.15 4.09 FB4BN(F,B)042 1200 550 33,800 9.90 3.63 9.30 28,200 8.26 4.03 FA4CN(F,C)036 1200 550 33,800 9.90 3.63 9.30 28,500 8.35 4.07 FA4CN(F,C)042 1200 550 34,400 10.08 3.62 9.50 29,200 8.56 4.17 FB4BN(F,B)042 1400 653 41,000 12.01 4.56 9.00 34,400 10.08 5.06 FB4BN(F,B)048 1400 653 41,500 12.16 4.51 9.20 35,000 10.25 5.00 FA4CN(F,C)042 1400 653 41,500 12.16 4.51 9.20 35,800 10.49 5.11 FA4CN(F,C)048 1400 653 42,400 12.42 4.56 9.30 36,600 10.72 5.23 FB4BN(F,B)048 1600 750 47,500 13.92 5.05 9.40 41,000 12.01 6.03 FB4BN(F,B)060 1600 750 48,500 14.21 5.16 9.40 42,000 12.31 6.00 FB4BNB070 1600 750 49,000 14.36 5.16 9.50 42,800 12.54 5.94 FA4CN(F,C)048 1600 750 48,000 14.06 5.05 9.50 42,800 12.54 6.11 FA4CN(F,C)060 1600 750 49,000 14.36 5.16 9.50 43,800 12.83 6.08 FB4BN(F,B)060 2000 919 57,500 16.85 6.39 9.00 49,500 14.50 7.62 FB4BNB070 2000 919 58,000 16.99 6.24 9.30 50,500 14.80 7.43 FA4CN(F,C)060 2000 919 58,000 16.99 6.24 9.30 50,500 14.80 7.43 * Ratings are based on: Standard: 80 F (27 C) db 67 F (19 C) wb indoor entering air temperature and 95 F (35 C) db air entering outdoor unit. NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 3. Minimum outdoor operating ambient in cooling mode is 55 F (12.8 C), maximum 125 F (51.7 C). 9

Detailed cooling capacities* (S.I.) EVAPORATOR AIR L/S 250 285 320 330 380 425 415 470 530 EWB CONDENSER ENTERING AIR TEMPERATURES C 24 29 35 41 46 52 al Sens ** al Sens ** al Sens ** al Sens ** al Sens ** al Sens ** 38CKS018-3A Outdoor With FA4CN(F,C)018 14 4.53 4.53 1.37 4.37 4.37 1.53 4.19 4.19 1.69 3.99 3.99 1.87 3.78 3.78 2.06 3.56 3.56 2.26 17 4.91 4.25 1.40 4.68 4.16 1.56 4.41 4.04 1.72 4.13 3.91 1.89 3.83 3.77 2.07 3.57 3.57 2.27 19 5.44 3.63 1.43 5.27 3.59 1.60 5.03 3.50 1.79 4.73 3.40 1.97 4.43 3.28 2.16 4.09 3.16 2.36 22 5.86 2.97 1.46 5.78 2.95 1.64 5.61 2.90 1.84 5.38 2.82 2.05 5.09 2.72 2.27 4.76 2.60 2.48 14 4.75 4.75 1.41 4.58 4.58 1.58 4.40 4.40 1.74 4.19 4.19 1.93 3.97 3.97 2.12 3.74 3.74 2.34 17 5.04 4.52 1.43 4.81 4.43 1.60 4.54 4.31 1.76 4.25 4.17 1.94 3.96 3.96 2.12 3.73 3.73 2.33 19 5.54 3.80 1.46 5.39 3.78 1.64 5.16 3.72 1.83 4.86 3.62 2.02 4.54 3.50 2.21 4.19 3.38 2.41 22 5.93 3.05 1.49 5.88 3.06 1.67 5.72 3.02 1.88 5.50 2.95 2.09 5.22 2.86 2.32 4.87 2.74 2.54 14 4.94 4.94 1.45 4.78 4.78 1.63 4.58 4.58 1.80 4.37 4.37 1.98 4.14 4.14 2.18 3.90 3.90 2.40 17 5.14 4.76 1.46 4.92 4.67 1.64 4.66 4.56 1.81 4.37 4.37 1.98 4.13 4.13 2.18 3.89 3.89 2.40 19 5.62 3.95 1.49 5.49 3.96 1.67 5.26 3.92 1.87 4.97 3.83 2.07 4.63 3.71 2.26 4.27 3.59 2.46 22 5.99 3.12 1.52 5.95 3.14 1.71 5.81 3.12 1.91 5.59 3.07 2.13 5.31 2.99 2.36 4.96 2.88 2.60 Multipliers for Determining the Performance With Other s Size Power Size Power FB4BNF 018 0.97 0.99 FA4CN(F,C) 024 1.01 1.00 024 1.00 1.00 38CKS024-3A Outdoor With FA4CN(F,C)024 14 6.47 6.47 1.87 6.06 6.06 2.03 5.63 5.63 2.20 5.22 5.22 2.39 4.81 4.81 2.58 4.43 4.43 2.80 17 6.97 6.12 1.92 6.42 5.79 2.07 5.89 5.48 2.24 5.34 5.15 2.40 4.82 4.82 2.59 4.42 4.42 2.80 19 7.76 5.24 1.97 7.25 5.00 2.15 6.70 4.73 2.35 6.14 4.46 2.53 5.57 4.19 2.72 5.02 3.93 2.92 22 8.44 4.30 2.01 8.01 4.12 2.21 7.51 3.91 2.42 6.97 3.69 2.64 6.40 3.46 2.87 5.82 3.22 3.10 14 6.81 6.81 1.94 6.37 6.37 2.11 5.94 5.94 2.28 5.49 5.49 2.47 5.06 5.06 2.67 4.65 4.65 2.89 17 7.16 6.53 1.96 6.62 6.20 2.14 6.07 5.86 2.30 5.51 5.51 2.47 5.05 5.05 2.67 4.65 4.65 2.89 19 7.93 5.52 2.01 7.44 5.30 2.20 6.89 5.05 2.40 6.31 4.77 2.61 5.71 4.49 2.79 5.14 4.22 2.99 22 8.57 4.43 2.06 8.15 4.28 2.26 7.66 4.08 2.47 7.12 3.87 2.69 6.56 3.64 2.92 5.96 3.40 3.17 14 7.09 7.09 1.99 6.64 6.64 2.18 6.19 6.19 2.36 5.72 5.72 2.55 5.27 5.27 2.75 4.84 4.84 2.98 17 7.32 6.90 2.01 6.77 6.54 2.19 6.22 6.22 2.37 5.72 5.72 2.55 5.27 5.27 2.75 4.84 4.84 2.98 19 8.07 5.78 2.06 7.58 5.58 2.25 7.02 5.33 2.45 6.44 5.07 2.66 5.82 4.77 2.86 5.23 4.49 3.06 22 8.65 4.54 2.10 8.25 4.41 2.31 7.77 4.23 2.52 7.23 4.03 2.75 6.67 3.81 2.98 6.07 3.59 3.23 Multipliers for Determining the Performance With Other s Size Power Size Power FB4BNF 024 0.99 1.00 FA4CN(F,C) 030 1.01 1.01 Size Power Size Power FB4BNF 030 0.99 1.00 FA4CN(F,C) 036 1.01 1.01 036 0.99 1.00 See notes on pg. 12. 030 1.00 1.00 38CKS030-3A Outdoor With FA4CN(F,C)030 14 8.23 8.23 2.49 7.64 7.64 2.64 7.07 7.07 2.81 6.50 6.50 2.97 5.96 5.96 3.15 5.43 5.43 3.33 17 8.80 7.77 2.54 8.08 7.30 2.70 7.36 6.85 2.85 6.66 6.39 3.00 6.00 6.00 3.15 5.42 5.42 3.33 19 9.75 6.63 2.60 9.04 6.27 2.79 8.30 5.90 2.98 7.55 5.51 3.15 6.82 5.13 3.31 6.13 4.78 3.48 22 10.59 5.42 2.67 9.93 5.13 2.87 9.22 4.83 3.07 8.49 4.52 3.27 7.74 4.20 3.48 7.00 3.88 3.68 14 8.63 8.63 2.58 8.02 8.02 2.74 7.40 7.40 2.91 6.80 6.80 3.08 6.24 6.24 3.26 5.68 5.68 3.44 17 9.02 8.28 2.60 8.29 7.80 2.78 7.56 7.30 2.93 6.84 6.84 3.08 6.23 6.23 3.26 5.68 5.68 3.44 19 9.96 6.98 2.67 9.24 6.64 2.86 8.50 6.27 3.05 7.72 5.87 3.24 6.97 5.49 3.40 6.26 5.11 3.57 22 10.76 5.60 2.73 10.11 5.33 2.93 9.39 5.04 3.14 8.65 4.73 3.34 7.90 4.41 3.55 7.15 4.10 3.76 14 8.95 8.95 2.65 8.33 8.33 2.84 7.69 7.69 3.01 7.07 7.07 3.18 6.48 6.48 3.36 5.90 5.90 3.55 17 9.20 8.74 2.66 8.47 8.23 2.85 7.73 7.73 3.01 7.07 7.07 3.18 6.47 6.47 3.36 5.90 5.90 3.55 19 10.11 7.31 2.73 9.39 6.97 2.92 8.64 6.61 3.12 7.86 6.22 3.31 7.08 5.82 3.48 6.35 5.42 3.65 22 10.87 5.76 2.79 10.23 5.51 3.00 9.52 5.22 3.20 8.77 4.92 3.41 8.01 4.61 3.62 7.25 4.29 3.83 Multipliers for Determining the Performance With Other s 10

Detailed cooling capacities* (S.I.) continued EVAPORATOR AIR CFM EWB CONDENSER ENTERING AIR TEMPERATURES C 24 29 35 41 46 52 al Sens ** al Sens ** al Sens ** al Sens ** al Sens ** al Sens ** 38CKS036-3A Outdoor With FA4CN(F,C)036 14 9.33 9.33 2.96 8.83 8.83 3.15 8.29 8.29 3.35 7.73 7.73 3.57 7.18 7.18 3.81 6.62 6.62 4.04 495 17 19 9.89 10.92 8.83 7.49 3.00 3.08 9.24 10.34 8.45 7.23 3.21 3.31 8.56 9.68 8.07 6.94 3.39 3.55 7.86 8.93 7.65 6.59 3.59 3.76 7.19 8.16 7.19 6.25 3.81 3.97 6.62 7.40 6.62 5.91 4.04 4.19 22 11.79 6.06 3.16 11.35 5.90 3.41 10.76 5.67 3.65 10.09 5.41 3.91 9.31 5.10 4.18 8.53 4.79 4.42 14 9.79 9.79 3.05 9.26 9.26 3.27 8.70 8.70 3.48 8.12 8.12 3.69 7.53 7.53 3.93 6.95 6.95 4.17 565 17 19 10.14 11.13 9.43 7.90 3.08 3.16 9.50 10.57 9.05 7.68 3.30 3.39 8.82 9.90 8.63 7.40 3.49 3.63 8.12 9.14 8.12 7.06 3.70 3.86 7.53 8.35 7.53 6.70 3.93 4.07 6.94 7.56 6.94 6.34 4.17 4.29 22 11.94 6.25 3.24 11.53 6.13 3.48 10.96 5.93 3.74 10.29 5.68 4.00 9.53 5.39 4.27 8.71 5.07 4.53 14 10.14 10.14 3.14 9.62 9.62 3.37 9.06 9.06 3.60 8.45 8.45 3.81 7.83 7.83 4.05 7.23 7.23 4.29 635 17 19 10.34 11.27 9.94 8.26 3.16 3.24 9.72 10.74 9.56 8.08 3.38 3.47 9.07 10.07 9.07 7.83 3.60 3.71 8.45 9.31 8.45 7.49 3.81 3.96 7.83 8.49 7.83 7.12 4.05 4.16 7.22 7.69 7.22 6.75 4.29 4.39 22 12.05 6.42 3.31 11.65 6.33 3.56 11.10 6.16 3.81 10.43 5.93 4.08 9.68 5.66 4.35 8.85 5.34 4.62 Multipliers for Determining the Performance With Other s Size Power Size Power FB4BNF 036 0.99 1.02 FA4CN(F,C) 042 1.02 1.00 FB4BN(F,B) 042 1.00 1.00 660 755 850 38CKS0042-3A Outdoor With FA4CN(F,C)042 14 11.03 11.03 3.55 10.53 10.53 3.82 9.98 9.98 4.11 9.42 9.42 4.41 8.87 8.87 4.71 8.28 8.28 5.01 580 17 19 11.94 13.14 10.27 8.77 3.64 3.74 11.25 12.56 9.92 8.53 3.93 4.07 10.53 11.86 9.56 8.24 4.19 4.41 9.76 11.05 9.17 7.89 4.46 4.69 9.03 10.25 8.77 7.56 4.74 4.98 8.29 9.42 8.29 7.21 5.01 5.26 22 14.10 7.15 3.83 13.71 7.02 4.19 13.13 6.80 4.54 12.42 6.53 4.90 11.59 6.20 5.26 10.74 5.88 5.57 14 11.59 11.59 3.68 11.06 11.06 3.97 10.49 10.49 4.26 9.89 9.89 4.56 9.30 9.30 4.87 8.68 8.68 5.18 660 17 19 12.25 13.41 10.96 9.21 3.73 3.83 11.57 12.86 10.62 9.04 4.05 4.17 10.82 12.16 10.23 8.77 4.31 4.51 10.04 11.33 9.80 8.42 4.59 4.82 9.31 10.49 9.31 8.08 4.87 5.11 8.67 9.63 8.67 7.73 5.18 5.40 22 14.30 7.36 3.92 13.94 7.27 4.28 13.38 7.08 4.64 12.68 6.84 5.01 11.86 6.54 5.37 10.98 6.21 5.72 14 12.04 12.04 3.78 11.51 11.51 4.12 10.92 10.92 4.41 10.29 10.29 4.71 9.67 9.67 5.02 9.02 9.02 5.34 745 17 19 12.49 13.60 11.58 9.59 3.81 3.91 11.83 13.08 11.25 9.49 4.14 4.26 11.08 12.38 10.83 9.25 4.43 4.60 10.31 11.54 10.31 8.93 4.71 4.94 9.66 10.67 9.66 8.58 5.02 5.23 9.01 9.79 9.01 8.21 5.34 5.52 22 14.42 7.53 4.00 14.09 7.49 4.37 13.56 7.34 4.74 12.87 7.12 5.10 12.06 6.85 5.48 11.17 6.53 5.83 Multipliers for Determining the Performance With Other s Size Power Size Power FB4BN(F,B) 042 0.99 1.01 FA4CN(F,C) 048 1.02 1.01 048 1.00 1.00 38CKS048-3A Outdoor With FA4CN(F,C)048 14 12.81 12.81 3.93 12.29 12.29 4.32 11.73 11.73 4.75 11.14 11.14 5.23 10.53 10.53 5.76 9.85 9.85 6.32 17 13.64 11.84 3.96 13.13 11.57 4.41 12.41 11.17 4.82 11.66 10.75 5.29 10.87 10.31 5.80 10.02 9.80 6.34 19 14.75 9.96 4.02 14.36 9.82 4.46 13.80 9.56 4.96 13.07 9.22 5.46 12.26 8.84 5.98 11.42 8.46 6.55 22 15.66 7.99 4.09 15.49 7.97 4.54 15.05 7.81 5.03 14.44 7.56 5.58 13.73 7.26 6.18 12.89 6.92 6.79 14 13.30 13.30 4.02 12.85 12.85 4.46 12.27 12.27 4.89 11.65 11.65 5.37 11.02 11.02 5.91 10.34 10.34 6.48 17 13.80 12.41 4.06 13.40 12.32 4.49 12.72 11.92 4.94 11.95 11.47 5.41 11.14 10.96 5.93 10.34 10.34 6.48 19 14.97 10.40 4.11 14.62 10.35 4.56 14.06 10.12 5.05 13.38 9.80 5.59 12.54 9.42 6.11 11.67 9.02 6.68 22 15.81 8.19 4.18 15.68 8.22 4.63 15.28 8.11 5.13 14.69 7.89 5.68 13.97 7.61 6.28 13.17 7.28 6.94 14 13.70 13.70 4.11 13.29 13.29 4.57 12.73 12.73 5.02 12.09 12.09 5.51 11.43 11.43 6.05 10.75 10.75 6.63 17 14.09 13.21 4.13 13.61 12.98 4.58 12.97 12.58 5.05 12.16 12.16 5.52 11.42 11.42 6.05 10.75 10.75 6.63 19 15.11 10.79 4.20 14.81 10.83 4.65 14.26 10.64 5.14 13.58 10.34 5.69 12.75 9.96 6.23 11.86 9.56 6.81 22 15.90 8.34 4.27 15.80 8.43 4.73 15.44 8.38 5.22 14.87 8.20 5.77 14.15 7.93 6.38 13.34 7.61 7.03 Multipliers for Determining the Performance With Other s Size Power Size Power FB4BN(F,B) 048 0.99 1.00 FB4BNF 070 1.02 1.02 060 1.01 1.02 FA4CN(F,C) 060 1.02 1.02 See notes on pg. 12. 11

Detailed cooling capacities* (S.I.) continued EVAPORATOR AIR CFM EWB CONDENSER ENTERING AIR TEMPERATURES C 24 29 35 41 46 52 al Sens ** al Sens ** al Sens ** al Sens ** al Sens ** al Sens ** 38CKS060-3A Outdoor With FA4CN(F,C)060 14 15.37 15.37 5.05 14.73 14.73 5.45 14.07 14.07 5.91 13.32 13.32 6.39 12.60 12.60 6.93 11.84 11.84 7.53 825 17 19 16.37 17.84 14.30 12.12 5.12 5.21 15.66 17.19 13.90 11.82 5.56 5.69 14.80 16.40 13.42 11.45 6.00 6.20 13.86 15.51 12.90 11.03 6.46 6.73 12.92 14.49 12.36 10.55 6.98 7.24 11.98 13.47 11.78 10.09 7.56 7.84 22 19.07 9.77 5.30 18.65 9.62 5.79 17.93 9.34 6.31 17.08 8.99 6.87 16.15 8.61 7.47 15.15 8.21 8.12 14 15.99 15.99 5.21 15.38 15.38 5.64 14.67 14.67 6.10 13.91 13.91 6.58 13.13 13.13 7.13 12.34 12.34 7.74 945 17 19 16.68 18.12 15.20 12.71 5.25 5.34 15.98 17.50 14.80 12.48 5.71 5.82 15.12 16.70 14.29 12.12 6.16 6.33 14.19 15.82 13.73 11.70 6.63 6.89 13.19 14.80 13.19 11.24 7.14 7.43 12.33 13.72 12.33 10.75 7.74 8.01 22 19.26 10.02 5.42 18.90 9.95 5.91 18.19 9.71 6.43 17.35 9.38 7.00 16.41 9.01 7.60 15.39 8.61 8.25 14 16.50 16.50 5.34 15.91 15.91 5.81 15.20 15.20 6.28 14.43 14.43 6.79 13.58 13.58 7.32 12.77 12.77 7.94 1060 17 19 16.94 18.32 16.01 13.24 5.37 5.45 16.23 17.74 15.59 13.09 5.83 5.94 15.41 16.93 15.07 12.76 6.31 6.46 14.48 16.03 14.48 12.35 6.80 7.02 13.57 15.05 13.57 11.90 7.32 7.61 12.76 13.92 12.76 11.39 7.94 8.17 22 19.38 10.23 5.54 19.05 10.23 6.04 18.40 10.04 6.56 17.55 9.74 7.12 16.60 9.38 7.72 15.57 9.00 8.36 Multipliers for Determining the Performance With Other s Size Power Size Power FB4BN(F,B) 060 1.01 1.01 FB4BNF 070 1.02 0.98 NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. * Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. al and sensible capacities are net capacities. Blower motor heat has been subtracted. Sensible capacities shown are based on 80 F (27 C) entering air at the indoor coil. For sensible capacities at other than 80 F (27 C), deduct 835 Btuh (245 ) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80 F (27 C), or add 835 Btuh (245 ) per 1000 CFM (480 L/S) of indoor coil air per degree above 80 F (27 C). ** Unit is total of indoor and outdoor unit kilowatts. EWB Entering Wet Bulb. 12

Detailed cooling capacities* (English) EVAPORATOR AIR CFM 525 600 675 700 800 900 875 1000 1125 EWB CONDENSER ENTERING AIR TEMPERATURES F 75 85 95 105 115 125 al Sens ** al Sens ** al Sens ** al Sens ** al Sens ** al Sens ** 38CKS018-3A Outdoor With FA4CN(F,C)018 57 15.47 15.47 1.37 14.92 14.92 1.53 14.29 14.29 1.69 13.62 13.62 1.87 12.89 12.89 2.06 12.16 12.16 2.26 62 16.77 14.51 1.40 15.97 14.19 1.56 15.06 13.80 1.72 14.08 13.36 1.89 13.09 12.85 2.07 12.17 12.17 2.27 67 18.55 12.38 1.43 17.97 12.24 1.60 17.16 11.94 1.79 16.15 11.59 1.97 15.11 11.20 2.16 13.96 10.78 2.36 72 19.99 10.13 1.46 19.73 10.08 1.64 19.16 9.91 1.84 18.37 9.63 2.05 17.37 9.27 2.27 16.24 8.88 2.48 57 16.23 16.23 1.41 15.64 15.64 1.58 15.00 15.00 1.74 14.29 14.29 1.93 13.54 13.54 2.12 12.78 12.78 2.34 62 17.21 15.42 1.43 16.41 15.12 1.60 15.49 14.72 1.76 14.52 14.22 1.94 13.52 13.52 2.12 12.75 12.75 2.33 67 18.92 12.96 1.46 18.39 12.90 1.64 17.60 12.69 1.83 16.59 12.34 2.02 15.50 11.95 2.21 14.29 11.53 2.41 72 20.25 10.40 1.49 20.06 10.43 1.67 19.54 10.31 1.88 18.76 10.07 2.09 17.81 9.77 2.32 16.63 9.36 2.54 57 16.85 16.85 1.45 16.31 16.31 1.63 15.64 15.64 1.80 14.91 14.91 1.98 14.12 14.12 2.18 13.30 13.30 2.40 62 17.55 16.24 1.46 16.79 15.94 1.64 15.90 15.55 1.81 14.92 14.92 1.98 14.10 14.10 2.18 13.29 13.29 2.40 67 19.19 13.48 1.49 18.72 13.52 1.67 17.94 13.37 1.87 16.95 13.07 2.07 15.81 12.68 2.26 14.57 12.25 2.46 72 20.46 10.64 1.52 20.30 10.72 1.71 19.82 10.66 1.91 19.07 10.48 2.13 18.12 10.22 2.36 16.94 9.82 2.60 Multipliers for Determining the Performance With Other s Size Power Size Power FB4BNF 018 0.97 0.99 FA4CN(F,C) 024 1.01 1.00 024 1.00 1.00 38CKS024-3A Outdoor With FA4CN(F,C)024 57 22.09 22.09 1.87 20.67 20.67 2.03 19.22 19.22 2.20 17.80 17.80 2.39 16.42 16.42 2.58 15.12 15.12 2.80 62 23.78 20.87 1.92 21.93 19.76 2.07 20.12 18.70 2.24 18.23 17.56 2.40 16.46 16.46 2.59 15.08 15.08 2.80 67 26.50 17.90 1.97 24.76 17.07 2.15 22.88 16.14 2.35 20.94 15.23 2.53 19.01 14.31 2.72 17.14 13.42 2.92 72 28.79 14.67 2.01 27.33 14.06 2.21 25.62 13.35 2.42 23.78 12.60 2.64 21.86 11.81 2.87 19.87 10.99 3.10 57 23.26 23.26 1.94 21.74 21.74 2.11 20.27 20.27 2.28 18.73 18.73 2.47 17.26 17.26 2.67 15.87 15.87 2.89 62 24.45 22.29 1.96 22.58 21.16 2.14 20.73 20.00 2.30 18.80 18.80 2.47 17.23 17.23 2.67 15.86 15.86 2.89 67 27.08 18.85 2.01 25.38 18.10 2.20 23.50 17.23 2.40 21.54 16.29 2.61 19.50 15.33 2.79 17.56 14.41 2.99 72 29.23 15.13 2.06 27.83 14.60 2.26 26.14 13.94 2.47 24.30 13.21 2.69 22.38 12.44 2.92 20.33 11.62 3.17 57 24.19 24.19 1.99 22.66 22.66 2.18 21.12 21.12 2.36 19.54 19.54 2.55 18.00 18.00 2.75 16.52 16.52 2.98 62 24.99 23.56 2.01 23.11 22.33 2.19 21.22 21.22 2.37 19.51 19.51 2.55 17.99 17.99 2.75 16.51 16.51 2.98 67 27.55 19.72 2.06 25.85 19.03 2.25 23.95 18.20 2.45 21.99 17.29 2.66 19.87 16.29 2.86 17.86 15.31 3.06 72 29.51 15.50 2.10 28.17 15.06 2.31 26.51 14.45 2.52 24.68 13.76 2.75 22.76 13.01 2.98 20.73 12.24 3.23 Multipliers for Determining the Performance With Other s Size Power Size Power FB4BNF 024 0.99 1.00 FA4CN(F,C) 030 1.01 1.01 030 1.00 1.00 38CKS030-3A Outdoor With FA4CN(F,C)030 57 28.10 28.10 2.49 26.08 26.08 2.64 24.11 24.11 2.81 22.17 22.17 2.97 20.33 20.33 3.15 18.53 18.53 3.33 62 30.02 26.51 2.54 27.56 24.93 2.70 25.11 23.37 2.85 22.73 21.81 3.00 20.47 20.47 3.15 18.51 18.51 3.33 67 33.26 22.61 2.60 30.84 21.39 2.79 28.32 20.12 2.98 25.76 18.79 3.15 23.29 17.52 3.31 20.92 16.30 3.48 72 36.15 18.49 2.67 33.90 17.52 2.87 31.47 16.48 3.07 28.97 15.41 3.27 26.42 14.33 3.48 23.89 13.23 3.68 57 29.46 29.46 2.58 27.37 27.37 2.74 25.26 25.26 2.91 23.21 23.21 3.08 21.29 21.29 3.26 19.39 19.39 3.44 62 30.78 28.27 2.60 28.31 26.62 2.78 25.80 24.93 2.93 23.35 23.35 3.08 21.28 21.28 3.26 19.39 19.39 3.44 67 33.98 23.84 2.67 31.54 22.65 2.86 29.00 21.38 3.05 26.36 20.05 3.24 23.80 18.73 3.40 21.35 17.45 3.57 72 36.71 19.11 2.73 34.50 18.20 2.93 32.06 17.19 3.14 29.54 16.14 3.34 26.95 15.06 3.55 24.41 13.98 3.76 57 30.54 30.54 2.65 28.42 28.42 2.84 26.25 26.25 3.01 24.14 24.14 3.18 22.10 22.10 3.36 20.13 20.13 3.55 62 31.39 29.83 2.66 28.92 28.09 2.85 26.37 26.37 3.01 24.12 24.12 3.18 22.09 22.09 3.36 20.12 20.12 3.55 67 34.50 24.93 2.73 32.05 23.80 2.92 29.48 22.55 3.12 26.83 21.23 3.31 24.18 19.85 3.48 21.67 18.50 3.65 72 37.11 19.65 2.79 34.92 18.80 3.00 32.48 17.82 3.20 29.93 16.78 3.41 27.34 15.74 3.62 24.75 14.65 3.83 Multipliers for Determining the Performance With Other s Size Power Size Power FB4BNF 030 0.99 1.00 FA4CN(F,C) 036 1.01 1.01 036 0.99 1.00 See notes on pg. 15. 13

Detailed cooling capacities* (English) continued EVAPORATOR AIR CFM EWB CONDENSER ENTERING AIR TEMPERATURES F 75 85 95 105 115 125 al Sens ** al Sens ** al Sens ** al Sens ** al Sens ** al Sens ** 38CKS036-3A Outdoor With FA4CN(F,C)036 57 31.84 31.84 2.96 30.13 30.13 3.15 28.28 28.28 3.35 26.39 26.39 3.57 24.50 24.50 3.81 22.61 22.61 4.04 1050 62 67 33.75 37.28 30.13 25.58 3.00 3.08 31.55 35.28 28.86 24.68 3.21 3.31 29.22 33.03 27.54 23.69 3.39 3.55 26.82 30.46 26.11 22.51 3.59 3.76 24.52 27.85 24.52 21.32 3.81 3.97 22.60 25.25 22.60 20.16 4.04 4.19 72 40.24 20.68 3.16 38.73 20.14 3.41 36.74 19.37 3.65 34.43 18.46 3.91 31.78 17.39 4.18 29.10 16.34 4.42 57 33.40 33.40 3.05 31.61 31.61 3.27 29.69 29.69 3.48 27.71 27.71 3.69 25.70 25.70 3.93 23.71 23.71 4.17 1200 62 67 34.61 38.00 32.19 26.96 3.08 3.16 32.43 36.08 30.90 26.20 3.30 3.39 30.10 33.80 29.46 25.25 3.49 3.63 27.72 31.20 27.72 24.09 3.70 3.86 25.69 28.50 25.69 22.86 3.93 4.07 23.70 25.80 23.70 21.64 4.17 4.29 72 40.76 21.34 3.24 39.35 20.92 3.48 37.41 20.24 3.74 35.12 19.38 4.00 32.52 18.41 4.27 29.73 17.31 4.53 57 34.62 34.62 3.14 32.85 32.85 3.37 30.93 30.93 3.60 28.84 28.84 3.81 26.74 26.74 4.05 24.66 24.66 4.29 1350 62 67 35.29 38.48 33.94 28.19 3.16 3.24 33.18 36.66 32.64 27.59 3.38 3.47 30.94 34.38 30.94 26.72 3.60 3.71 28.83 31.77 28.83 25.57 3.81 3.96 26.73 28.98 26.73 24.30 4.05 4.16 24.65 26.24 24.65 23.03 4.29 4.39 72 41.12 21.92 3.31 39.77 21.60 3.56 37.88 21.02 3.81 35.61 20.23 4.08 33.03 19.31 4.35 30.21 18.24 4.62 Multipliers for Determining the Performance With Other s Size Power Size Power FB4BNF 036 0.99 1.02 FA4CN(F,C) 042 1.02 1.00 FB4BN(F,B) 042 1.00 1.00 1400 1600 1800 38CKS042-3A Outdoor With FA4CN(F,C)042 57 37.65 37.65 3.55 35.94 35.94 3.82 34.07 34.07 4.11 32.16 32.16 4.41 30.26 30.26 4.71 28.26 28.26 5.01 1225 62 67 40.74 44.85 35.07 29.92 3.64 3.74 38.41 42.87 33.87 29.12 3.93 4.07 35.92 40.49 32.62 28.14 4.19 4.41 33.32 37.71 31.29 26.94 4.46 4.69 30.82 34.97 29.94 25.79 4.74 4.98 28.29 32.14 28.29 24.62 5.01 5.26 72 48.12 24.41 3.83 46.80 23.94 4.19 44.82 23.19 4.54 42.40 22.28 4.90 39.55 21.15 5.26 36.67 20.07 5.57 57 39.57 39.57 3.68 37.75 37.75 3.97 35.79 35.79 4.26 33.75 33.75 4.56 31.73 31.73 4.87 29.61 29.61 5.18 1400 62 67 41.81 45.78 37.42 31.43 3.73 3.83 39.50 43.90 36.26 30.85 4.05 4.17 36.94 41.50 34.92 29.92 4.31 4.51 34.28 38.66 33.44 28.75 4.59 4.82 31.77 35.80 31.77 27.58 4.87 5.11 29.59 32.87 29.59 26.39 5.18 5.40 72 48.81 25.12 3.92 47.58 24.81 4.28 45.67 24.18 4.64 43.29 23.33 5.01 40.49 22.34 5.37 37.49 21.21 5.72 57 41.08 41.08 3.78 39.29 39.29 4.12 37.25 37.25 4.41 35.12 35.12 4.71 32.99 32.99 5.02 30.78 30.78 5.34 1575 62 67 42.64 46.41 39.52 32.74 3.81 3.91 40.39 44.64 38.40 32.38 4.14 4.26 37.81 42.26 36.95 31.57 4.43 4.60 35.18 39.40 35.18 30.48 4.71 4.94 32.98 36.42 32.98 29.27 5.02 5.23 30.77 33.41 30.77 28.02 5.34 5.52 72 49.22 25.72 4.00 48.10 25.55 4.37 46.27 25.05 4.74 43.92 24.29 5.10 41.16 23.38 5.48 38.13 22.30 5.83 Multipliers for Determining the Performance With Other s Size Power Size Power FB4BN(F,B) 042 0.99 1.01 FA4CN(F,C) 048 1.02 1.01 048 1.00 1.00 38CKS048-3A Outdoor With FA4CN(F,C)048 57 43.73 43.73 3.93 41.94 41.94 4.32 40.03 40.03 4.75 38.02 38.02 5.23 35.95 35.95 5.76 33.62 33.62 6.32 62 46.57 40.42 3.96 44.81 39.47 4.41 42.37 38.13 4.82 39.78 36.70 5.29 37.11 35.18 5.80 34.19 33.45 6.34 67 50.36 33.99 4.02 49.03 33.53 4.46 47.09 32.64 4.96 44.62 31.45 5.46 41.85 30.17 5.98 38.96 28.86 6.55 72 53.45 27.28 4.09 52.85 27.19 4.54 51.37 26.65 5.03 49.28 25.80 5.58 46.86 24.79 6.18 43.99 23.60 6.79 57 45.40 45.40 4.02 43.86 43.86 4.46 41.87 41.87 4.89 39.77 39.77 5.37 37.60 37.60 5.91 35.30 35.30 6.48 62 47.11 42.35 4.06 45.73 42.04 4.49 43.40 40.69 4.94 40.77 39.14 5.41 38.02 37.40 5.93 35.28 35.28 6.48 67 51.09 35.51 4.11 49.91 35.32 4.56 48.00 34.54 5.05 45.66 33.44 5.59 42.80 32.14 6.11 39.82 30.80 6.68 72 53.96 27.94 4.18 53.50 28.05 4.63 52.16 27.69 5.13 50.13 26.94 5.68 47.68 25.96 6.28 44.94 24.84 6.94 57 46.75 46.75 4.11 45.37 45.37 4.57 43.43 43.43 5.02 41.27 41.27 5.51 39.01 39.01 6.05 36.69 36.69 6.63 62 48.07 45.07 4.13 46.44 44.29 4.58 44.25 42.93 5.05 41.51 41.51 5.52 38.99 38.99 6.05 36.67 36.67 6.63 67 51.56 36.82 4.20 50.54 36.95 4.65 48.67 36.32 5.14 46.35 35.31 5.69 43.53 34.01 6.23 40.48 32.64 6.81 72 54.27 28.47 4.27 53.92 28.78 4.73 52.71 28.60 5.22 50.74 27.97 5.77 48.29 27.05 6.38 45.54 25.97 7.03 Multipliers for Determining the Performance With Other s Size Power Size Power FB4BN(F,B) 048 0.99 1.00 FB4BNF 070 1.02 1.02 060 1.01 1.02 FA4CN(F,C) 060 1.02 1.02 See notes on pg.15. 14

Detailed cooling capacities* (English) continued EVAPORATOR AIR CFM EWB CONDENSER ENTERING AIR TEMPERATURES F 75 85 95 105 115 125 al Sens ** al Sens ** al Sens ** al Sens ** al Sens ** al Sens ** 38CKS060-3A Outdoor With FA4CN(F,C)060 57 52.46 52.46 5.05 50.29 50.29 5.45 48.01 48.01 5.91 45.47 45.47 6.39 42.99 42.99 6.93 40.41 40.41 7.53 1750 62 67 55.86 60.88 48.81 41.36 5.12 5.21 53.43 58.67 47.43 40.35 5.56 5.69 50.50 55.98 45.80 39.08 6.00 6.20 47.31 52.95 44.02 37.64 6.46 6.73 44.11 49.44 42.18 36.02 6.98 7.24 40.89 45.97 40.21 34.45 7.56 7.84 72 65.10 33.33 5.30 63.64 32.85 5.79 61.19 31.89 6.31 58.29 30.70 6.87 55.13 29.40 7.47 51.70 28.02 8.12 57 54.58 54.58 5.21 52.48 52.48 5.64 50.07 50.07 6.10 47.46 47.46 6.58 44.80 44.80 7.13 42.12 42.12 7.74 2000 62 67 56.94 61.85 51.86 43.37 5.25 5.34 54.55 59.74 50.50 42.58 5.71 5.82 51.62 57.00 48.78 41.35 6.16 6.33 48.42 53.98 46.87 39.94 6.63 6.89 45.01 50.50 45.01 38.35 7.14 7.43 42.10 46.83 42.10 36.70 7.74 8.01 72 65.72 34.20 5.42 64.49 33.96 5.91 62.10 33.14 6.43 59.22 32.02 7.00 56.00 30.75 7.60 52.53 29.39 8.25 57 56.30 56.30 5.34 54.30 54.30 5.81 51.86 51.86 6.28 49.25 49.25 6.79 46.35 46.35 7.32 43.58 43.58 7.94 2250 62 67 57.81 62.53 54.65 45.19 5.37 5.45 55.41 60.54 53.22 44.69 5.83 5.94 52.59 57.78 51.42 43.54 6.31 6.46 49.41 54.70 49.41 42.15 6.80 7.02 46.33 51.36 46.33 40.61 7.32 7.61 43.56 47.49 43.56 38.89 7.94 8.17 72 66.14 34.93 5.54 65.03 34.93 6.04 62.78 34.28 6.56 59.90 33.25 7.12 56.65 32.01 7.72 53.15 30.71 8.36 Multipliers for Determining the Performance With Other s Size Power Size Power FB4BN(F,B) 060 1.01 1.01 FB4BNF 070 1.02 0.98 NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. * Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. al and sensible capacities are net capacities. Blower motor heat has been subtracted. Sensible capacities shown are based on 80 F (27 C) entering air at the indoor coil. For sensible capacities at other than 80 F (27 C), deduct 835 Btuh (245 ) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80 F (27 C), or add 835 Btuh (245 ) per 1000 CFM (480 L/S) of indoor coil air per degree above 80 F (27 C). ** Unit is total of indoor and outdoor unit kilowatts. EWB Entering Wet Bulb 15

Condenser only ratings (S.I.) SST C -1 2 4 7 10 13-1 2 4 7 10 13-1 2 4 7 10 13 See notes on pg. 18. CONDENSER ENTERING AIR TEMPERATURES C 13 18 24 29 35 41 46 52 38CKS018-3A TCG 4.80 4.30 3.90 3.40 3.00 2.50 2.10 1.60 SDT 28.00 33.00 37.00 41.00 45.00 50.00 54.00 58.00 KW 1.22 1.25 1.29 1.31 1.33 1.34 1.35 1.34 TCG 5.50 5.00 4.50 4.00 3.50 3.10 2.60 2.10 SDT 29.00 34.00 38.00 43.00 47.00 51.00 55.00 60.00 KW 1.25 1.30 1.34 1.38 1.40 1.43 1.44 1.45 TCG 6.40 5.70 5.20 4.70 4.10 3.60 3.10 2.70 SDT 30.00 35.00 40.00 44.00 49.00 53.00 57.00 61.00 KW 1.28 1.34 1.40 1.45 1.48 1.51 1.54 1.55 TCG 7.40 6.60 5.90 5.40 4.80 4.30 3.70 3.20 SDT 31.00 36.00 41.00 45.00 50.00 54.00 59.00 63.00 KW 1.30 1.37 1.44 1.51 1.57 1.59 1.63 1.66 TCG 8.60 7.60 6.80 6.20 5.60 5.00 4.40 3.90 SDT 32.00 38.00 42.00 47.00 51.00 56.00 60.00 65.00 KW 1.33 1.41 1.48 1.56 1.63 1.69 1.73 1.76 TCG 10.20 8.90 7.80 7.10 6.40 5.80 5.20 4.60 SDT 33.00 39.00 44.00 48.00 53.00 57.00 61.00 66.00 KW 1.34 1.44 1.53 1.61 1.68 1.76 1.83 1.90 38CKS024-3A TCG 6.90 6.30 5.60 5.00 4.30 3.70 3.10 2.50 SDT 28.00 33.00 37.00 41.00 46.00 50.00 55.00 59.00 KW 1.57 1.62 1.67 1.71 1.74 1.76 1.78 1.79 TCG 7.90 7.20 6.50 5.80 5.10 4.50 3.90 3.20 SDT 29.00 34.00 39.00 43.00 47.00 52.00 56.00 61.00 KW 1.62 1.70 1.75 1.80 1.85 1.88 1.91 1.94 TCG 9.00 8.20 7.50 6.70 6.00 5.30 4.60 4.00 SDT 30.00 35.00 40.00 45.00 49.00 53.00 58.00 62.00 KW 1.67 1.76 1.85 1.91 1.96 2.00 2.04 2.09 TCG 10.30 9.30 8.50 7.70 7.00 6.20 5.50 4.80 SDT 32.00 37.00 41.00 46.00 50.00 55.00 60.00 64.00 KW 1.72 1.82 1.92 2.01 2.09 2.13 2.18 2.24 TCG 11.80 10.60 9.70 8.80 8.00 7.30 6.50 5.70 SDT 33.00 38.00 43.00 47.00 52.00 56.00 61.00 65.00 KW 1.75 1.87 1.98 2.09 2.19 2.28 2.34 2.40 TCG 13.40 12.20 11.10 10.10 9.20 8.40 7.60 6.70 SDT 34.00 39.00 44.00 49.00 53.00 58.00 62.00 67.00 KW 1.78 1.93 2.05 2.17 2.28 2.39 2.49 2.59 38CKS030-3A TCG 8.20 7.50 6.80 6.10 5.50 4.80 4.20 3.50 SDT 28.00 33.00 37.00 42.00 46.00 51.00 55.00 60.00 KW 1.85 1.96 2.05 2.13 2.21 2.27 2.33 2.37 TCG 9.20 8.50 7.70 7.00 6.30 5.70 5.00 4.30 SDT 29.00 34.00 39.00 43.00 48.00 52.00 57.00 61.00 KW 1.92 2.04 2.15 2.25 2.34 2.42 2.49 2.55 TCG 10.40 9.60 8.80 8.00 7.30 6.50 5.80 5.10 SDT 30.00 35.00 40.00 44.00 49.00 54.00 58.00 63.00 KW 1.96 2.12 2.27 2.37 2.47 2.57 2.65 2.73 TCG 11.80 10.80 9.90 9.10 8.30 7.50 6.70 6.00 SDT 32.00 36.00 41.00 46.00 50.00 55.00 60.00 64.00 KW 2.01 2.18 2.35 2.50 2.62 2.72 2.82 2.91 TCG 13.30 12.20 11.20 10.30 9.50 8.60 7.80 7.00 SDT 33.00 38.00 42.00 47.00 52.00 56.00 61.00 65.00 KW 2.05 2.24 2.43 2.60 2.75 2.90 3.01 3.11 TCG 15.00 13.80 12.70 11.70 10.70 9.90 8.90 8.10 SDT 34.00 39.00 44.00 48.00 53.00 57.00 62.00 67.00 KW 2.08 2.30 2.50 2.69 2.86 3.03 3.18 3.34 16

Condenser only ratings (S.I.) continued SST C -1 2 4 7 10 13-1 2 4 7 10 13-1 2 4 7 10 13 See notes on pg. 18. CONDENSER ENTERING AIR TEMPERATURES C 13 18 24 29 35 41 46 52 38CKS036-3A TCG 9.50 8.80 8.00 7.20 6.30 5.50 4.60 3.60 SDT 28.00 33.00 37.00 42.00 46.00 50.00 55.00 59.00 KW 2.21 2.34 2.44 2.55 2.65 2.73 2.79 2.82 TCG 10.70 9.90 9.10 8.20 7.40 6.50 5.60 4.60 SDT 29.00 34.00 39.00 43.00 48.00 52.00 56.00 61.00 KW 2.28 2.44 2.56 2.68 2.80 2.91 2.99 3.05 TCG 12.10 11.20 10.30 9.40 8.50 7.60 6.60 5.60 SDT 30.00 35.00 40.00 45.00 49.00 53.00 58.00 62.00 KW 2.36 2.52 2.70 2.82 2.95 3.08 3.19 3.28 TCG 13.70 12.60 11.60 10.70 9.80 8.70 7.70 6.70 SDT 31.00 36.00 41.00 46.00 50.00 55.00 59.00 64.00 KW 2.44 2.61 2.79 2.97 3.12 3.25 3.38 3.50 TCG 15.60 14.20 13.10 12.10 11.10 10.00 9.00 7.90 SDT 32.00 37.00 42.00 47.00 52.00 56.00 61.00 65.00 KW 2.51 2.70 2.89 3.08 3.28 3.46 3.59 3.72 TCG 17.80 16.30 14.80 13.70 12.60 11.50 10.30 9.30 SDT 33.00 38.00 44.00 48.00 53.00 57.00 62.00 66.00 KW 2.57 2.78 2.99 3.19 3.40 3.61 3.82 3.99 38CKS042-3A TCG 12.10 11.20 10.10 9.10 8.10 7.20 6.10 5.00 SDT 28.00 32.00 37.00 42.00 46.00 51.00 55.00 60.00 KW 2.75 2.95 3.06 3.18 3.29 3.38 3.43 3.44 TCG 13.70 12.50 11.50 10.40 9.30 8.30 7.30 6.10 SDT 29.00 34.00 38.00 43.00 47.00 52.00 56.00 61.00 KW 2.82 3.06 3.22 3.36 3.49 3.60 3.67 3.71 TCG 15.60 14.20 13.00 11.80 10.70 9.50 8.40 7.30 SDT 29.00 35.00 39.00 44.00 49.00 53.00 58.00 62.00 KW 2.90 3.16 3.39 3.57 3.69 3.82 3.92 3.98 TCG 17.80 16.10 14.70 13.40 12.20 10.90 9.70 8.50 SDT 30.00 36.00 41.00 45.00 50.00 55.00 59.00 64.00 KW 2.96 3.25 3.51 3.75 3.95 4.06 4.17 4.26 TCG 20.60 18.50 16.70 15.20 13.90 12.50 11.20 10.00 SDT 31.00 37.00 42.00 46.00 51.00 56.00 60.00 65.00 KW 3.00 3.34 3.63 3.89 4.12 4.34 4.46 4.57 TCG 24.40 21.20 19.10 17.30 15.80 14.40 12.80 11.50 SDT 32.00 38.00 43.00 48.00 52.00 57.00 62.00 66.00 KW 3.02 3.41 3.74 4.03 4.29 4.53 4.74 4.93 38CKS048-3A TCG 13.10 12.70 11.90 11.20 10.30 9.40 8.50 7.50 SDT 28.00 34.00 39.00 44.00 48.00 53.00 58.00 63.00 KW 2.93 3.22 3.47 3.75 4.04 4.35 4.66 4.97 TCG 14.30 13.90 13.30 12.50 11.60 10.70 9.70 8.70 SDT 29.00 34.00 40.00 45.00 50.00 54.00 59.00 64.00 KW 2.96 3.27 3.59 3.86 4.17 4.49 4.82 5.16 TCG 15.50 15.10 14.60 14.00 13.10 12.10 11.00 10.00 SDT 29.00 35.00 40.00 46.00 51.00 56.00 61.00 65.00 KW 2.99 3.31 3.65 4.01 4.31 4.64 4.99 5.35 TCG 16.90 16.40 15.90 15.20 14.50 13.60 12.60 11.40 SDT 30.00 36.00 41.00 47.00 52.00 57.00 62.00 67.00 KW 3.03 3.35 3.70 4.07 4.46 4.82 5.18 5.54 TCG 18.40 17.80 17.20 16.60 15.90 15.10 14.20 13.10 SDT 30.00 36.00 42.00 47.00 53.00 58.00 63.00 68.00 KW 3.07 3.40 3.75 4.13 4.53 4.95 5.41 5.79 TCG 20.00 19.40 18.80 18.10 17.30 16.50 15.60 14.60 SDT 30.00 37.00 43.00 48.00 53.00 59.00 64.00 69.00 KW 3.08 3.44 3.80 4.18 4.60 5.03 5.49 5.98 17

Condenser only ratings (S.I.) continued SST C -1 2 4 7 10 13 KW Outdoor Unit Kilowatts Only SDT Saturated Temperature Leaving Compressor ( C) SST Saturated Temperature Entering Compressor ( C) TCG Gross CONDENSER ENTERING AIR TEMPERATURES C 13 18 24 29 35 41 46 52 38CKS060-3A TCG 16.20 15.50 14.70 13.70 12.60 11.60 10.40 9.20 SDT 28.00 34.00 38.00 43.00 48.00 53.00 58.00 63.00 KW 3.66 3.98 4.29 4.65 5.03 5.44 5.86 6.28 TCG 17.60 17.10 16.30 15.30 14.20 13.10 12.00 10.70 SDT 29.00 35.00 40.00 45.00 50.00 54.00 59.00 64.00 KW 3.73 4.10 4.46 4.81 5.19 5.62 6.07 6.53 TCG 19.10 18.60 17.90 17.00 15.90 14.70 13.60 12.30 SDT 30.00 36.00 41.00 46.00 51.00 56.00 61.00 65.00 KW 3.78 4.19 4.59 5.01 5.41 5.81 6.28 6.77 TCG 20.70 20.20 19.50 18.60 17.70 16.50 15.20 14.00 SDT 31.00 37.00 42.00 47.00 52.00 57.00 62.00 67.00 KW 3.83 4.25 4.69 5.14 5.63 6.10 6.54 7.06 TCG 22.50 21.90 21.10 20.30 19.30 18.20 17.00 15.80 SDT 31.00 37.00 43.00 48.00 53.00 58.00 63.00 68.00 KW 3.88 4.30 4.75 5.23 5.73 6.27 6.84 7.40 TCG 24.40 23.80 23.00 22.00 21.00 19.90 18.70 17.50 SDT 32.00 38.00 44.00 49.00 54.00 59.00 64.00 69.00 KW 3.89 4.35 4.82 5.30 5.82 6.36 6.93 7.54 18