EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

Similar documents
ENERVEX ADC100 DRAFT CONTROL

ADC150 Automatic Draft Control

EBC 12 Modulating Fan Control

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

EFC 211 Fan Control USA CAN. ... Chapter 5. Start Up and Configuration. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

MEC 18 Mechanical Exhaust Control

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

RSIB Power Venter

RS Chimney Fan for Solid Fuel Applications

RS Chimney Fan for Solid Fuel Applications

MFD Mechanical Fireplace Damper

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

MDVS Tag: DF-1, DF-2. Architect/Engineer: Contractor: EXHAUSTO Job File: Use. Sizes. Listings. Description. CSI Specifications.

ENERVEX IPVB INLINE POWER VENTER

EW 40 Wireless Fan Control

ENERVEX RSV CHIMNEY FAN

External Roof-mounted Power Vent System

ENERVEX MFD MECHANICAL FIREPLACE DAMPER

RS Chimney Fan for Gas & Oil Applications

RS Chimney Fan for Gas & Oil Applications

IPVB EC inline power venter

GSV 9-16 Grease Fan for Solid Fuel Applications. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

RS chimney fan for gas and oil applications

RSHT Volko Supply USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual

GSV Grease Fan

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

ENERVEX MDF MODULATING DAMPER

ENERVEX GSV GREASE FAN

LGB Gas fired boiler

24 VAC SYSTEM CONTROL KIT

EXHAUSTO Inc in North America In Atlanta since ,000 sq.ft. office and warehouse 86 authorized sales and service offices in USA and Canada.

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

EBC12-EU-01. Product Instruction fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

CSD-1 COMMERCIAL BOILER CONTROLS

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

24 VAC SYSTEM CONTROL KIT

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

POWER VENTER. Model: PVE Series

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

Multistory Fireplace & Exhaust System

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

PVE SERIES POWER VENTER SYSTEM MANUAL

Control manual and troubleshooting guide

24 VAC SYSTEM CONTROL KIT

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

SYSTEM CONTROL KIT. Model: CK-62. Designed for use on SWG Series Power Vent Hoods for controlling oil fired heating appliances with 120 VAC controls.

TJERNLUND PRODUCTS, INC.

(Information about THERMAL dampers for gas-fired appliances available on request.) WARNING

Designing Thoughtful Green Performance - On-Demand Venting and Exhaust Systems

NEW. Demand-Controlled Exhaust Systems for Commercial and Industrial Bakeries. For Commercial and industrial Baking Oven Systems

Tjernlund Side Wall Venting Products

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

120 VAC SYSTEM CONTROL KIT

WARNING FLAIR INTERNATIONAL CORPORATION 600 OLD WILLETS PATH HAUPPAUGE, NEW YORK U.S.A. TEL.: (516) FAX: (516) AMERICAN

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

COMBUSTION AIR SYSTEM

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

ENERVEX GSV GREASE FAN

ENERVEX VHX VORTEX HEAT RECOVERY CENTER

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

Operator: Save these instructions for future use!

Model Universal Oil Primary Control

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Model 60200FR Gas Primary Control Data Sheet

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SLANT/FIN AUTOMATIC VENT DAMPER For Galaxy, Sentinel and Sentry Series Boilers INSTALLATION INSTRUCTION MANUAL AND TROUBLESHOOTING GUIDE

ELECTRONIC FIREPLACE DAMPER

Instructions. Easy-wire terminal strip Microprocessor-operated. Easy remote sense. Self-checking program. Diagnostic/status LED s

FOR YOUR SAFETY WARNING FOR YOUR SAFETY IMPORTANT CAUTION

ELECTRONIC FIREPLACE DAMPER

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

Installation, Operation and Service Manual

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Installation Requirements for Models:

INSTALLATION GUIDE Dual Fuel Ranges

DIVISION FINNED WATER-TUBE BOILERS

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

SECTION HEATING BOILERS

Power Supply Display Module PSDM. Installation and Operation Manual

CR Series Command Relays

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Revitalize Building Mechanical Systems (4619)

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

Public Safety DAS Annunciator Panel

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

CHAPTER 8 CHIMNEYS AND VENTS

OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: Unit Serial # Purchased From Company Address

Transcription:

Installation & Operating Manual EBC 10 Fan Control USA CAN Product Information... Chapter 1+2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration... Chapter 5 Maintenance and Troubleshooting... Chapter 6 Job Name: Installer: Installation Date: READ AND SAVE THESE INSTRUCTIONS! EXHAUSTO Inc. 1200 Northmeadow Pkwy. Suite 180 Roswell, GA 30076 P: 770.587.3238 F: 770.587.4731 T: 800.255.2923 info@exhausto.com us.exhausto.com

1. Product Information 2. Specifications 3. Mechanical Installation 4. Electrical Installation 1.1 Function...3 1.2 Shipping...3 1.3 Warranty...3 2.1 Dimensions & Capacities...4 3.1 Location...5 3.2 Mounting of Control Unit...5 3.3 Connection of the Proven Draft Switch...6 3.4 Installation of the Stack Probe...6 3.5 Adjusting the Fan Speed...7 4.1 General...8 4.2 Wiring of Heating Appliance...9 4.3 Wiring of Gas Fireplace...10 4.4 Wiring of 3-Phase Fans... 11 4.5 Wiring with a Variable Frequency Drive...12 4.6 Connection of an External Proven Draft Switch...13 5. Startup and Configuration 5.1 General...14 5.2 Sequence of Operation...14 5.3 Setting the Operating Pressure...14 6. Maintenance and Troubleshooting...15 Symbol Legend: The following terms are used throughout this manual to bring attention to the presence of potential hazards or to important information concerning the product. Danger: Indicates an imminent hazardous situation which, if not avoided, will result in death, serious injury or substantial property damage.! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed on the front of the manual. 2. Before servicing or cleaning the unit, switch off at service panel and lock service panel to prevent power from being switched on accidentally. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with applicable codes and standards. 4. Follow the appliance manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. This unit must be grounded.! Caution: Indicates an imminent hazardous situation which, if not avoided, may result in personal injury or property damage. How to use this manual This installation manual does not contain any system design documentation. System design documentation is available from any authorized EXHAUSTO representative. Accessories, fans and variable frequency drives are not covered by this manual. Please refer to these component s individual manuals. 2

1. Product Information 1.1 Function Use The EXHAUSTO EBC 10-P or 10-E Fan Control is for use with single heating appliances where modulation is not required. It is designed to monitor and create proper draft and pressure in a chimney system. The control may be used with EXHAUSTO fan models RS, RSV, GSV, RSIB and RSIF. Typical uses include controlling draft for a gas-fired water heater, boiler, furnace, fireplace, stove, BBQ or pizza oven. Function The EBC 10-P integrates a fan speed control and an internal Proven Draft Switch (PDS) with a pressure probe. The EBC 10-E integrates a fan speed control only. This model must be connected to an external EXHAUSTO PDS-1 to provide the same functions as the EBC 10-P. The user can set the control to run the exhaust fan continuously. When used with a 3-phase exhaust fan a Variable Frequency Drive (VFD) is required. It will allow the user to manually adjust the speed of the fan while it is in use. The control can also be interlocked with the appliance to make the pre-purge and post-purge functions available. The pre-purge function prevents the operation of a heating appliance until the set draft point has been reached. The post-purge function allows the fan to operate for 12 minutes after the appliance has been shut down. This allows any excess flue gases or products of combustion to evacuate the chimney system. When the EBC 10 is connected to an internal or external PDS, the control provides a safety function that prevents an appliance from operating in the event of an electrical or mechanical failure. The PDS is supplied with a pressure probe that constantly senses the draft in the chimney. If insufficient draft exists, the control will gradually increase the fan speed until the draft-set point is satisfied. If this point is not satisfied after 12 seconds, the control will shut down the appliance. There is an automatic reset on the control to prevent nuissance lockouts or the need for manual reset. Construction Code Compliance The housing is made of NEMA 1 rated polycarbonate. System installation must conform to the requirements of the authority having jurisdiction. When required by the authority having jurisdiction, the installation must also conform to the NFPA31, NFPA54 or NFPA211. All electrical wiring must be in accordance with the requirements of the authority having jurisdiction or, in absence of such requirements, with the National Electric Code, NFPA 70. Listings 1.2 Shipping The circuit board and other components in the EXHAUSTO EBC 10 are ETL or UL listed. EBC 10-P EBC 10 Control Unit with internal PDS stack pressure probe and silicone tubing EBC 10-E EBC 10 Control Unit without PDS Optional: External PDS, stack pressure probe and silicone tubing. 1.3 Warranty * If other components are shipped, they will appear as separate items on the packing list. Complete warranty conditions are available from EXHAUSTO, Inc. 3

2. Specifications 2.1 Dimensions & Capacities EBC 10 Control Power supply V 1x120VAC Amperage A 6.3 Operating temperature F/ C -4 to 122/-20 to 50 Control signal ma max. 10 Control relay Max. 120 VAC/8A Output VAC 10-120 VDC 0-10 Weight lbs/kg 3.0/1.5 EBC10-P EBC10-E 4

3. Mechanical Installation 3.1 Location The EBC 10 Control Unit must be installed indoors in the vertical position, preferably in the room where the appliance is located. As shown in the diagram below, the control will be wired directly to a 120/1/60 VAC power supply. The control will also be wired into the appliance and the junction box provided with the fan. For detailed wiring information, see Chapter 4. EBC 10-P Fig. 1 FAN Fig. 2 EBC 10-E JUNCTION BOX PROBE DISCONNECT SWITCH (by others) EBC 10 CONTROL EXHAUSTO EBC 10 1/4" SILICONE TUBING PROBE EXHAUSTO EXHAUSTO 1/4" SILICONE TUBING APPLIANCE CONTROL INTERLOCK WIRING 10-120V POWER SUPPLY 120/1/60 APPLIANCE 3.2 Mounting the Control Unit The EBC 10 control may be mounted directly to a wall. To mount, remove the cover and locate the (4) mounting holes. Using the hole-pattern shown below, mount the control using the appropriate sized hardware. Once it is attached, the unit may be wired in accordance with Chapter 4 and the cover may be replaced. Fig. 3 (4) MOUNTING HOLES 5

3.3 Connection of the Proven Draft Switch A Proven Draft Switch (PDS) must be used with the EBC 10 control as a system safety device. The PDS monitors the pressure inside the stack and signals the control to shut down the appliance if insufficient draft exists. A stack probe senses the pressure read by the PDS and is connected via silicone tubing. For model EBC 10-P, connect the silicone tubing through the port located at the bottom of the control enclosure as shown in Fig. 4 (this port is connected to the internal PDS). The other end should be attached to the stack probe. Fig. 4 For model EBC 10-E, an external PDS-1 must be wired to terminals 16, 17 and 18 of the control. The silicone tubing will run from the PDS-1 to the pressure probe. For wiring detail, see Chapter 4. The standard tube length is 6 feet. The distance can be extended up to 25 feet by using 1/4 rigid plastic or copper tubing as temperature allows (not supplied). 3.4 Installation of the Stack Probe Connection for tubing at the bottom of the enclosure The probe must be installed between the appliance and the exhaust fan. Locate the probe at least a distance three (3) vent diameters away from any elbow or tee. For fireplace installations, the stack probe should be installed as close to the exhaust fan as possible. If the probe is installed on a horizontal pipe, it must be installed above the centerline of the pipe. See Fig. 5. To produce an accurate pressure reading, the probe should be installed as close to flush as possible with the inner wall of the stack. If double walled stack is used, the probe should be flush with the inner most wall. Fig. 5 Ø Ø 6

3.5 Adjusting the Fan Speed A potentiometer is located on the main control board of the EBC 10. This is used to manually increase or decrease the speed of the fan. To increase the fan speed, rotate the potentiometer clockwise. Alternately, rotating the potentiometer counterclockwise will decrease the fan speed. Fig. 6 Potentiometer 7

4. Electrical Installation 4.1 General Danger: Turn off electrical power before servicing. Contact with live electric components can cause shock or death.! EBC 10 is designed for 1x120VAC power supply only. The designations for each terminal on the control board are shown below. Note that some installations may not require the use of all terminals. Also shown in this section is a general connection diagram for an EBC 10 control system. Fig. 7 Terminal Use Terminal Use 1 Power Supply - L1 16 PDS- Common 2 Power Supply - N 17 PDS- Normally Closed 3 Power Supply - Ground 18 PDS- Normally Open 4-5 Voltage Input from Appliance Thermostat 19 Chimney Fan- L1 Optocoupler (-) (10-120 VAC/CDC) 6-7 Voltage Input from Appliance Thermostat 20 Chimney/Exhaust Fan- N Optocoupler (+) (10-120 VAC/CDC) (regulating) 8 24 VDC power supply to dry set of 21 Chimney/Exhaust Fan- Ground contacts (appliance thermostat) 9 0 VDC power supply to dry set of 25 Control Signal for VFD (0 VDC) contacts (appliance thermostat) 14 Burner Relay Contact- Common 26 Control Signal for VFD (0 to 10 VDC) (MAX. 120 VAC, 8 amps) 15 Burner Relay Contact- Normally Open (MAX. 120 VAC, 8 amps) 8

4.2 Wiring of Heating Appliance The figure below shows the connection of the control directly into the gas valve feeding the appliance. In the event of an electrical/ mechanical failure or insufficient draft, the control shuts off the gas supply causing the appliance to shut down. The EBC 10-P may also be wired directly to the appliance control (see Fig. 11). If necessary, the control shuts the appliance down by opening the safety circuit. Fig. 8 NOTE: EBC 10-E DOES NOT INCLUDE A PDS. EXTERNAL PDS-1 IS REQUIRED 9

4.3 Wiring of Gas Fireplace When connecting the EBC 10 to a gas fireplace, terminals 5 and 9 should be connected to a wall switch. When the switch is closed, the system is activated. Once proper draft is achieved, the control releases the gas-valve and allow fuel flow. When the switch is turned off, the control cuts off the fuel flow and the fireplace. In the event of insufficient draft or mechanical/ electrical failure, the proven draft switch and control will shut off the gas valve. Fig. 9 * Shielded Cable 10

4.4 Wiring of 3-Phase Fans The EBC 10 can be wired to a 3-phase fan system by incorporating a Variable Frequency Drive. Fig. 10 shows the connection diagram of this scenario. Wiring detail for this type of system is shown in Fig. 11. Fig. 10 EXHAUSTO 11

4.5 Wiring with a Variable Frequency Drive The EBC 10 Control can be installed with a Variable Frequency Drive (VFD). This allows the fan speed to be manually adjusted by the user depending on draft conditions. When using a VFD, the fan is NOT connected directly to the control. The VFD is connected to terminals 25 and 26. The wires running from the fan junction box is connected into the VFD via terminals W, V and U as shown in the Fig. 11. Fig. 11 12

4.6 Connection of an External Proven Draft Switch For the EBC 10-E, an external PDS-1 must be installed. The wiring of this is shown in Fig. 12. A PDS-1 must be used in any of the applications mentioned previously. Fig. 12 # Wires: 3 x 24 AWG (4 x 0.6 mm) Max. Length: 300 (100m) Max. Voltage: 24 V DC <0.1 Amps. USE SHIELDED CABLE 13

5. Startup and Configuration 5.1 General Dip switches are located on the control board. Verify settings using the table below. DIP SWITCH NAME OFF ON 1 MANUAL RESET Automatic reset at power failure or insufficient draft Manual reset at power failure or insufficient draft NOTE: The dip switches will always be OFF if no Proven Draft Switch is connected. 2 POST PURGE No post-purge 12 minutes of postpurge 3 PDS CHECK No monitoring to see if the PDS was in NC position prior to start The PDS must be in NC position prior to start 5.2 Sequence of Operation Start Sequence Operating Sequence Shutdown Sequence 1. The appliance energizes EBC 10 inputs at terminals 5 and 6 to initiate the call for heat. 2. The EBC 10 control sets fan output to 100%. 3. The Proven Draft Switch closes when adequate draft is achieved and EBC 10 slows fan to set speed. 4. The EBC 10 control releases the appliance for operation by closing dry contact between terminals 14 and 15. 1. The control adjusts fan output to the percentage set by the control board Potentiometer. 2. If the Proven Draft Switch opens, fan output is set to 100% and a 12 sec. timing cycle starts. 3. If the Proven Draft Switch has not been made within 12 sec., the appliance output turns off and an alarm condition exists. 4. If the Proven Draft Switch closes, the control automatically resumes normal operation at step 3 of start sequence. 1. The call for heat signal from the appliance is turned off. 2. Fan output continues at pre-set speed for 12 minutes if post purge cycle is selected at dip switch. 3. Fan output is set to zero 5.3 Setting the Operating Pressure The operating pressure of the EBC 10 Control should be set by the user prior to using the system. This pressure should be set within the range the appliance manufacturer has specified in the appliance manual. The user must use a manometer or other device to read the pressure inside the stack. For draft hoods or diverters and fireplaces, a standard smoke/ flame test should be performed before normal operation (specified in appliance manual). 14

6. Maintenance and Troubleshooting Observation Problem Solution Heating appliance/ fireplace cycle on and off - Fan speed control is set too low. - Fan speed control is bad - Increase fan speed setting - Replace fan speed control. Fan is hunting (increasing speed and then decreasing speed constantly) Heating appliance/ fireplace will not come on Heating appliance/ fireplace will not shut off - Fan speed control is set too low. - Proven draft switch setting is too high - Fan is not working - No power to the EBC 10 - Proven draft switch is not properly connected to the chimney. - Relay or proven draft switch is bad - Proven draft switch is not wired correct - EBC 10 is not wired correctly - Relay or proven draft switch is bad - Increase fan speed setting. - Lower the pressure setting on the proven draft switch - Move Stack Probe closer to fan. - Check the fan and if necessary, repair or replace. Check wiring, it may not be receiving start command. - Connect power to EBC 10 - Make sure the probe is properly inserted into the stack, so the tip of the probe is flush with the inside of the chimney. If serving a fireplace the probe should be 3 to 4 below the fan. - Replace relay or switch - Check wiring and correct. - Check wiring and correct. - Replace relay 15

EXHAUSTO Inc. 1200 Northmeadow Pkwy. Suite 180 Roswell, GA 30076 P: 770.587.3238 F: 770.587.4731 T: 800.255.2923 info@exhausto.com us.exhausto.com