MDVS Tag: DF-1, DF-2. Architect/Engineer: Contractor: EXHAUSTO Job File: Use. Sizes. Listings. Description. CSI Specifications.

Similar documents
MEC 18 Mechanical Exhaust Control

EBC 12 Modulating Fan Control

ADC150 Automatic Draft Control

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

ENERVEX ADC100 DRAFT CONTROL

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

ENERVEX RSV CHIMNEY FAN

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

EXHAUSTO Inc in North America In Atlanta since ,000 sq.ft. office and warehouse 86 authorized sales and service offices in USA and Canada.

IPVB EC inline power venter

ENERVEX IPVB INLINE POWER VENTER

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

RSIB Power Venter

Designing Thoughtful Green Performance - On-Demand Venting and Exhaust Systems

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

EFC 211 Fan Control USA CAN. ... Chapter 5. Start Up and Configuration. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

ENERVEX GSV GREASE FAN

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

RS chimney fan for gas and oil applications

RS Chimney Fan for Gas & Oil Applications

RS Chimney Fan for Gas & Oil Applications

EW 40 Wireless Fan Control

ENERVEX BEF BOX VENTILATOR

ENERVEX BEF BOX VENTILATOR

Direct Fired Heater Model AD Specification

ENERVEX MDF MODULATING DAMPER

Multistory Fireplace & Exhaust System

Technical data Chimney fans, controllers & accessories in systems for multiple heating appliances

RS Chimney Fan for Solid Fuel Applications

RSHT Volko Supply USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

ENERVEX VHX VORTEX HEAT RECOVERY CENTER

NEW. Demand-Controlled Exhaust Systems for Commercial and Industrial Bakeries. For Commercial and industrial Baking Oven Systems

Indirect Gas-Fired Make-Up Air

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

ENERVEX TDF POWER VENTER

Revitalize Building Mechanical Systems (4619)

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

MFD Mechanical Fireplace Damper

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

RS Chimney Fan for Solid Fuel Applications

Direct Gas-Fired Make-Up Air

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

ENERVEX MFD MECHANICAL FIREPLACE DAMPER

Power Flame Incorporated

EBC12-EU-01. Product Instruction fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

Modular Supply Make-Up Air Unit

Precise Temperature Control; Compact Footprint

Multistory Fireplace & Exhaust System

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

External Roof-mounted Power Vent System

on-demand Minimizing Energy Loss through order to meet Sustainable Design Standards

A TRUE GAME CHANGER - The Vortex Heat Recovery Center CONDENSING EFFICIENCIES FOR TRADITIONAL BOILERS & HEATERS

Electric Coils. Blower Coils. Product Information

ENERVEX GSV GREASE FAN

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

DIVISION FINNED WATER-TUBE BOILERS

Technical data. Chimney fans, controls and accessories for gas fireplaces, stoves and single non-modulating gas boilers G A S

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

5 year fan housing and motor warranty

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Modular Heating & Ventilating Unit Model IGX-HV

Submittal Data Performance Data Electrical Data

Union County Vocational - Technical Schools Scotch Plains, New Jersey

DIVISION FINNED WATER-TUBE BOILERS

Temperature Controllers

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

FT900BD FLIGHT-TYPE DISHWASHER

SENTRA Series Water Unit

AC Backward Curved Motorized Impellers

C1210ES Tankless Water Heater

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

A. Product Data: Include rated capacities, furnished specialties and accessories.

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

Selecting the Correct Fan

108A OTP1800. Grid Support. General Description

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

C1050ES Tankless Water Heater

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

fans & heaters SIMPLE, ROBUST AND RELIABLE

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

DIVISION FINNED WATER-TUBE BOILERS

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Transcription:

3913017 03.15 Submittal Data MDVS 250-500 Tag: DF-1, DF-2 Job Name: Parkside Memory Cottage ALF Representative: Tom Barrow Company Job Location: Port Charlotte, FL Job #: 80036 Architect/Engineer: Contractor: EXHAUSTO Job File: Use The MDVS TM, Modulating Dryer Venting System, is a mechanical exhaust system used to control and maintain proper pressure and exhaust for multiple commercial or industrial laundry dryers. Description The MDVS TM system consists of an exhaust fan, the BESB Box Ventilator, the MEC18 Mechanical Exhaust Control, XTP pressure transducer and a VFD-Variable Frequency Drive (3-phase ventilators only). The MEC18 maintains a constant pressure for the dryers by modulating the speed of the BESB Box Ventilator. The MDVS TM system is supplied as a complete package with ventilator(s), control(s), pressure sensor, duct probe and adapters for mounting on a duct or a wall. Sizes The system is available in multiple sizes as shown on the following page. Listings ETL-listed to UL705 for Power Ventilators with special consideration given to the transport of lint-laden air. CSI Specifications CSI Model Specifications are available from ENERVEX and via the internet at us.exhausto.com. The document number is: 3917003. Operation The pressure set-point must be programmed manually via the potentiometer on the MEC18 control board. Other parameters, such as optional post purge and manual/ automatic reset, may be set with the dipswitches on the control board. The clothes dryers are not interlocked with the MEC18. When one or more clothes dryers are in operation, the control increases the speed of the ventilator to maintain the pressure set-point. When a clothes dryer shuts down, the MEC18 reduces the ventilator speed to maintain the setpoint. This sequence is repeated every time clothes dryer operation is initiated. When no dryers are in operation, the ventilator runs at an idle speed to maintain the pressure set-point. If proper exhaust cannot be maintained because of mechanical or electrical failure, the control will go into alarm mode and run the ventilator at 100% speed. If the ventilator experiences mechanical or electrical failure, the MEC18 will send and alarm signal to the building management system. This will not interrupt dryer operation because they are not interlocked with the control.

3913017 03.15 Submittal Data MDVS 250-500 MEC18 TP DUCT PROBE ABB Max. RPM MEC18 ENERVEX Inc. 1685 Bluegrass Lakes Pkwy. Alpharetta, GA 30004 P: 770.587.3238 F: 770.587.4731 T: 800.255.2923 info@enervex.com www.enervex.com

3902010 08.13 Product Information Box Ventilator BESB Description The BESB Box Ventilator is a high-efficiency ventilator with a backward curved centrifugal impeller. The BESB is completely insulated to reduce noise and condensation. The BESB is used in both intake and exhaust applications The fan is designed to exhaust lint-laden air from single or multiple type I and type II residential and commercial clothes dryers, exhaust commerical hoods, or to provide make-up air for laundry or mechanical rooms. The BESB Box Ventilator is a component in the MCAS Modulating Combustion Air System and MDVS Mechanical Dryer Venting System. Material The ventilator housing is galvanized steel, while the impeller is cast aluminum. The design is Type B, Spark Resistant Construction. A service door is provided to allow easy access to the motor and impeller. Impeller is cast aluminum and balanced with permanently attached lead balancing weights. Motor The BESB is equipped with an energy-efficient, totally enclosed, variable speed motor (TEFC). Commercial grade, 1 or 3-phase motor. Class A insulated, IP54 Protection Class. Sealed ball bearings. Thermal overload protection. Standard Equipment Slip connections with silicone seals. Junction Box Accessories EBC 12 Modulating Fan Control EBC 14 Pressure Control MEC 18 Exhaust Control EBC 30 Modulating Pressure Control Variable Frequency Drive, VFD Flexible connections, FLF Proven Draft Switch, PDS Listings UL705, Standard for Power Ventilators with special consideration for venting lint-laden air from single or multiple dryers and CSA 22.2 No. 113, Standard for Fans and Ventilators. Component in an ETL Listed MCAS System Component in an ETL Listed MDVS System CE compliant Manufactured at ISO9001 certified plant Complies with and meets Type B, Spark Resistant Construction per AMCA standard 99-0401 classifications of Spark Resistant Construction. Warranty 2 year factory warranty Specifications are subject to change without notice.

3902010 08.13 Product Information Specifications Model BESB 250 BESB 315 BESB 400 BESB 500 Fan Type Motor Type Capacity Centrifugal Impeller (B-Wheel) TEFC Voltage V AC 1x120 3 x 200-240/3x440-480 Amperage Amps 5.8 2.6/1.9 5.5/2.9 7.8/4.1 Motor Output HP 0.5 1 2 3 kw 0.35 0.75 1.5 2.2 RPM 1600 1720 Weight lbs 110 126 167 227 Duct Connection kg 50 57 76 103 E in 10 12 16 20 mm 250 315 400 500 Dimensions A in 30.91 30.91 35.24 38.98 mm 785 785 895 990 B in 24.61 26.57 30.51 33.86 mm 625 675 775 860 C in 12.80 13.98 15.35 16.73 mm 325 355 390 425 D in 7.68 7.68 10.24 12.20 mm 195 195 260 310 G in 31.50 31.50 31.50 33.46 mm 800 800 800 800 H in 13.78 15.16 17.32 19.09 mm 350 385 440 485 J in 18.90 17.91 20.67 22.83 mm 480 455 525 580 K in 7.28 8.08 9.84 11.81 mm 185 205 250 300 L in 4.92 4.92 4.92 6.69 mm 125 125 125 170 M in 2.36 3.15 3.15 2.36 mm 60 80 80 60 Sound Diagrams Model Lw db (measured in accordance with ISO 3744) Lp db 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz (A) BESB 250 78 76 67 59 56 48 38 72 BESB 315 71 76 68 66 61 54 46 71 BESB 400 78 82 74 74 67 61 50 78 BESB 500 82 85 78 77 69 66 57 81 ENERVEX Inc. 1685 Bluegrass Lakes Pkwy. Alpharetta, GA 30004 P: 770.587.3238 F: 770.587.4731 T: 800.255.2923 info@enervex.com www.enervex.com

3932010 05.12 Product Information Mechanical Exhaust Control MEC 18 Use The MEC 18 is a fan control used to monitor pressure in single or multi-story building exhaust applications. The control modulates the fan speed to maintain proper and constant pressure in the exhaust system. The MEC 18 is used with models EFV, BESF and BESB. The MEC 18 is for indoor installations only. Typical uses include: clothes dryer venting, bathroom and kitchen exhaust and other building venting applications. Description The MEC 18 monitors pressure in an exhaust duct via a XTP2 Sensor. The XTP2 constantly senses the pressure in the duct and as the pressure varies, the control adjusts the speed of the fan to maintain the pressure set-point. The MEC 18 operates a single phase fan using a 10-120 VAC signal. The control sends a 0-10 VDC signal to a Variable Frequency Drive to operate a 3- phase fan. When the system is energized, the fan begins to run at full speed. Once the pressure setpoint is reached in the duct, the control adjusts the fan speed to maintain proper pressure. The control contains an optional integrated safety system that shuts down the appliance(s) in the event of a mechanical or electrical fan failure. For multiple appliance interlock one or more ES12 controls may be required. The control has fast reaction times (max. 20 seconds) and a very stable control signal assuring accurate fan operation. Material Enclosure is made of polycarbonate and is NEMA 4x rated. Standard Equipment MEC 18 Control Box XTP2 Sensor Stack Probe and Silicone Tubing XTP2 Sensor MEC 18 Control Box Listings ETL listed to UL508 and CSA C22.2 No. 14-95; Standard for Industrial Control Equipment CE Compliant Manufactured at ISO9001 certified plant. Warranty 2-year factory warranty Silicone Tubing Chimney Probe Specifications are subject to change without notice.

3932010 05.12 Product Information Specifications MEC 18 Control Power supply V 1x120VAC Amperage A 6.3 Operating temperature F/ C -4 to 122 / -20 to 50 Range of operation inwc/pa 0-0.6 / 0-150 Tolerance inwc/pa 0.01 / 3 +/-10% Output Current ma max. 10 Max. Load 120 VAC / 8A Real-time PID Control Method Infinitely variable Real-time PID Signal Stability +/- 0.5% Ramp Up/Down Time Seconds max 20 Output VAC 10-120 VDC 0-10 Dimensions A in/mm 7.17 / 182 B in/mm 7.09 / 180 C in/mm 4.37 / 111 Weight lbs/kg 3.0 / 1.5 EMC standard Emission EN50 081-1 Immunity EN50 082-2 XTP2 Sensor Power supply VDC 12-36 Amperage ma <20 Output VDC 0-10 Operating temperature F/ C 0 to 160 / -18 to 71 Accuracy +/- 0.08% Dimensions D in/mm 3.70 / 94 E in/mm 5.12 / 130 F in/mm 6.18 / 157 G in/mm 3.13 / 80 Weight lbs/kg.6 /.3 Chimney Probe Dimensions H in/mm 4.25 / 108 I in/mm 3.50 / 89 MEC MEC 18 18 ENERVEX Inc. 1685 Bluegrass Lakes Pkwy. Alpharetta, GA 30004 P: 770.587.3238 F: 770.587.4731 T: 800.255.2923 info@enervex.com www.enervex.com