Operation Manual. An investment of a small amount of time to review this manual will ensure proper performance of your Coal-Trol Digital system.

Similar documents
Coal-trol Digital - Model TS2 V3

Corn-trol Digital - Model TS2C V3-83. Instruction Manual

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

Thermostat Remote Control & Receiver

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

Humidity Module OWNER S MANUAL. Complete Control from

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

7-Day. Digital Thermostat. residential. & 2-cool

5+2 Day. up to HEAT COOL

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Non-Programmable Digital Thermostat

2 - Wire Programmable Digital Thermostat

Programmable 5-2 Day Digital Thermostat

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

5+2 DAY PROGRAMMABLE DIGITAL THERMOSTAT

Programmable Digital Thermostat

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

1 For All Programmable Digital Thermostat

OWNER'S MANUAL T0140. Contents Page #

Installation Instructions

User s Information Manual

Programmable 5-2 Day Digital Thermostat

user s information manual

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEU22P7S RESIDENTIAL. Model HVAC SERVICE PARTS

Owner s Manual. Digital Thermostat

Owner s Manual. 5+2 Day Programmable Digital Thermostat

Corn Flame Energy Corn Stove Model 3000

TC --- NHP, TC --- NAC Comfort Series Non---Programmable Thermostat. Owner s Manual

Legacy Non-Programmable Owner s Manual

Installation Instructions

Installation Instructions

Installation, Start -Up, and Operating Instructions

Programmable Digital Thermostat

CT500 Electronic Thermostat

Owner s Manual. Digital Thermostat. Non-Programmable

Performance Non-Programmable Owner s Manual

Performance Non-Programmable Owner's Manual

USER MANUAL. REVOLVE F20 (Repeat Cycle and Light Combo Timer ) AutopilotControllers.com APE2200

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

Thermostats. Digital Non-Programmable. GEAppliances.com. Owner s Manual & Installation Instructions RAK148D2 RAK164D2

Programmable Load Management Thermostat

Home and Building Control Home and Building Control Helping You Control Your World

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Digital Non-Programmable

CT2700 An Electronic Round Programmable Thermostat

MULTI HEAT PUMP PANEL CASSETTE TYPE DUCTLESS INVERTER INDOOR UNIT OWNER'S MANUAL. Models: CH12CC230VI CH18CC230VI CH24CC230VI

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Interrupted Ignition Series Oil Primary Control

INSTALLATION INSTRUCTIONS

GA3650TB Blower Accessory

Universal Fan and Light Remote Control

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

Residential Duct Mount Builder s Box Media Air Cleaner

Quest Power Electric Heat EHS 31 Pro

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

5+2 DAY INSTALLATION. Digital Thermostat. residential. & 1-cool. up to. 1-heat PROGRAMMABLE HEAT COOL HEAT PUMP THERMOSTAT. Venstar Inc.

TCONT402AN32DA. Owner s Manual. Comfort Control XR402. Pub. No Fan Mode. Filter/OD

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Thermostats. Digital Programmable. GEAppliances.com

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

Digital Programmable

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Thermostat Series. Installation Manual TSTBM-RRS--TW-A Revised 02-13

Quest Power Electric Heat EHS 62 Pro

TJERNLUND PRODUCTS, INC.

For Quick Set-Up go to Page 14

READ AND SAVE THESE INSTRUCTIONS

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Cookshack, Inc. Model FEC100 Fast Eddy Oven. Version /1/10

IMPORTANT SAFETY INFORMATION:

e Bath Fan with Light User s Guide

ELECTRIC FIREPLACE OWNER S MANUAL

ELECTRONIC COMMUNICATING THERMOSTAT : P COOL AUTO. Owner's Manual

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

VT SERIES VERTICAL TOASTER OPERATOR S MANUAL TABLE OF CONTENTS

INSTALLER S & OWNER S MANUAL

Electronic Pellet Burner Controller NPBC-V3M

USER S INFORMATION MANUAL NT-16SQ NT-20SQ

BLOWER ACCESSORY MODEL #FIB100 Español p. 17

INSTALLER S & OWNER S MANUAL

Safety, Installation, and Operation Manual

e Heater/Exhaust Fan/Light User s Guide

Owner s Manual Phoenix FireBird

FOR EASY, FAST INSTALLATION AND FOR RESULTS

Refer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System.

e Bath Fan with Light User s Guide

ELECTRONIC COMMUNICATING THERMOSTAT COOL AUTO. Hold Prog Mode Fan. Owner's Manual. RC-120 Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool

Installation, Operation & Service Manual

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

Projection Alarm Clock USER GUIDE

flexibility programmed settings.

Transcription:

Page 1 Welcome To a new era in solid fuel heating. You have chosen to improve your household comfort and increase the efficiency of your heating dollars. The Coal-trol Digital system has been specifically developed to improve the performance and convenience of your anthracite coal stove. A new type of digital thermostat and solid-state control module make this possible. An investment of a small amount of time to review this manual will ensure proper performance of your Coal-Trol Digital system. Introduction This manual is a companion to the the Coal-trol Digital Installation Manual. Here it is assumed that your Coal-trol Digital system is installed and working. Please refer to the Coal-trol Digital Installation Manual for installation, setup, and important safety information, not reprinted here. Table of Contents Page Number Coal-trol Digital Feature Overview 2 For Service and repair 3 Coal-trol Digital Limited Warranty 3 Stoker Stove Terminology 4 Operating Features of the Thermostat 5 Automatic and Manual Stoker Control 6 MENU Button Operation 7 Round-robin Temperature/Time Display 8 Day Temperature Setting (Daytime Setback) 8 Night Temperature Setting (Nighttime Setback) 9 Manual Temperature Setting (Setback Override) 9 Room Over-Temperature Cutout 10 Coal-trol Digital Model 1 Specifications 11 SYRACUSE NY Copyright 2004, 2005 Automation Correct LLC. All rights reserved. Coal-trol Digital, Pelli-stat by Automation Correct LLC All others trademarks by the respective owners.

Page 2 Coal-trol Digital Feature Overview The Coal-trol Digital Model-1 is a complete control system designed for automatically fed stoker stoves and furnaces utilizing anthracite fuel. The stove-mounted Power Module and the wallmounted Coal-trol Thermostat work together to supervise all stove operations and maintain room temperature to within ±1 F of the desired setting. The Power Module controls the coal feed rate, combustion blower fan, convection blower fan, fire igniter (additional hardware required when available), and the power vent blower. A safety interlock circuit for a high temperature (Bonnet Limit) and a loss of power vent air flow circuit (Fume Limit) are provided within the Power Module, and may be bypassed if not required by the particular installation. All connections to stove blowers, motors, and safety interlocks are done through standard 120VAC cord receptacles. The Power Module has a power On/Off switch, and LED status indicators for all control elements. The Coal-trol Thermostat may be located up to 100 ft. from the Power Module. Proper temperature control only requires that the heat generated by the stove is readily communicated to the thermostat. (A forced air furnace located in the basement with the thermostat mounted upstairs can work fine). Fuel feed is continuously adjusted to maintain room temperature as set on the Coal-trol thermostat. The Convection blower is automatically started and continuously adjusted to match the heat output of the stove. Two temperature setbacks automatically change the temperature at prescribed times set by the user on a 24 hour time cycle. A room high temperature limit shuts off the stove if feeder failure occurs. The initial setup of minimum and maximum feed rates, and selection of either dual-motor or single motor (Tri-Burner) stoker styles, allow Coal-trol Digital application to a wide variety of stove configurations and brands. A One-touch Feed mode assists in starting a fire by continuously stoking coal for 10 minutes at a 100% rate. All settings, except for time of day clock, are maintained during power loss without batteries. Power loss ride-through allows the thermostat to continue stove operation if power is restored within 1 minute. Power-on Test Mode sequences all motors and blowers to assist in installation and troubleshooting. The Coal-trol Thermostat features an LCD display, two LED indicators, and four pushbuttons for indication and control of all settings.

For Service or Repair Page 3 Contact your dealer, or our company. Automation Correct LLC 405 Parrish Lane Syracuse, NY 13205 Phone: (315) 299 3589 Email: support@automationcorrect.com Web: www.automationcorrect.com Coal-trol Digital Limited Warranty THREE-YEAR WARRANTY Automation Correct LLC (us) warrants this product to be free from defects in material and workmanship. If a defect is found within three years from the date of original installation of the product (whether or not actual use begins on that date) Automation Correct LLC will provide a new or remanufactured part, at our sole option, to replace any defective part, without charge for the part itself. This warranty does not include labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of either defective parts or replacement parts. Warranty Conditions: 1. Warranties only apply to products in their original installation location. 2. Installation, use, care, and maintenance must be normal and in accordance with the instructions contained in the, Installation Manual and Automation Correct LLC's Service Information. 3. Defective parts must be returned to us or an authorized dealer for credit. 4. All work performed during normal business hours. 5. This warranty applies only to residential use. LIMITATIONS OF WARRANTIES All implied warranties (including implied warranties of merchantability and fitness for a particular purpose) are hereby limited in duration to the period for which the LIMITED WARRANTY is given and applies. Some states do not allow limitations on how long an implied warranty lasts, so the above may not apply to you. The expressed warranties made in this warranty are exclusive and may not be altered, enlarged, or changed by any distributor, dealer, or other person whatsoever. Automation Correct LLC will not be responsible for: 1. Damage or repairs as a consequence of faulty installation, misapplication, abuse, improper servicing, unauthorized alteration or improper operation. 2. Failure to operate due to voltage conditions, blown fuses, open circuit breakers or other conditions beyond the control of Automation Correct LLC. 3. Parts not supplied or designated by us, or damages resulting from their use. 4. Automation Correct LLC products installed outside the 50 US states or Canada. 5. Cost of heating fuel of any kind whatsoever including electricity. 6. Any special indirect or consequential property or commercial damage of any nature whatsoever. Some states do not allow the exclusion of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you also may have other rights, which vary from state to state.

Stoker Stove Terminology Page 4 Ash Bin Barometric Damper Bonnet Limit Switch Combustion Blower Convection Blower The container to collect ash produced by burning coal. An air-flow regulator to balance gas pressure in stove or furnace. This ensures proper draft conditions. A temperature switch that shuts down the stove or furnace when a high-limit temperature is exceeded. The Bonnet Limit must be used with stoves or furnaces that have it as original equipment i.e. Keystoker brand. A small motor designed to supply the air needed for combustion of coal. Tri-Burner type stoker mechanisms do not have a separate combustion blower. Also called a Draft Inducer. A large fraction horsepower blower designed to supply warm air into the room. Also called a Circulation Fan. Fuel Hopper The storage hopper for coal. Feeds coal (by gravity) into the stoker. Fume Switch Power Vent Round-robin Stoker Stove Tri-Burner A safety limit-switch which verifies proper chimney (flue) exhaust flow. Used with Power Vent chimney systems. A Chimney(flue) system where an electric blower forces the airflow needed for exhaust of combustion gases. Also called Direct Vent. The Fume Switch circuit must be used with a Power Vent chimney system. The action of the LCD display to indicate the current time, the temperature setting, and the actual temperature, sequentially in turn. The fuel grate, motor, and mechanism used to introduce coal to the burn chamber. This is also called the Feeder. The term stove as used in this manual, refers to residential anthracite fired stoves and furnaces used for supplemental or primary space heating. A stoker mechanism where one motor provides both the fuel feed and combustion air.

Coal-trol Digital Model 1 Operating Features of the Thermostat Page 5 Purpose of the Buttons and Lights each press will display next setting. DOWN button each press will decrease a setting. Press and hold to decrease fast. Also used to enter SETUP menu settings. UP button each press will increase a setting. Press and hold to increase fast. Also used to enter SETUP menu settings. AUTO/MANUAL button 1) Each momentary press will switch thermostat between Automatic temperature control and Manual feeder control. When in AUTO the Manual light is Off. When in MANUAL the Manual Light is On. Must be in AUTO for control of room temperature. 2) If the button is pressed for 3-seconds, fuel is stoked continuously at 75% of the maximum rate, for 5 minutes. MANUAL Light Red LED that when On indicates that thermostat is in Manual Stoker control mode. FEED Light Green LED that when On indicates that thermostat is commanding the stoker to feed fuel. Automation Correct LLC 9/2005 R1 www.automationcorrect.com

Page 6 Automatic and Manual Stoker Control Normally, the Coal-trol Thermostat should be set to AUTO mode. This is indicated by the MANUAL indicator light being off. This allows the thermostat to adjust the stove feeder to maintain the room temperature to the temperature setting. Manual Feeder Control has been provided for initial stove setup, and to replicate non-thermostat control methods, found on many stoker fed stoves. For some stove owners, Manual Feeder control is useful to boil Maple syrup on their stovetop. The Coal-trol Digital Thermostat operates similar to a car with a cruise control. If the cruise control is off, the speed of the car is controlled by how far the gas pedal is pressed down by the driver. When the cruise control is on, the speed setting determines how far the gas pedal is pressed down and the control automatically adjusts the setting when going up or down a hill, thereby maintaining the desired speed to the speed setting. Like a car with a cruise control, your stove with the Coal-trol Digital thermostat can be operated with automatic temperature control on or off. This is the purpose of the AUTO/MANUAL button on the thermostat. When the Coal-trol Digital Thermostat is in Automatic, the red Manual light is off, and the amount of fuel feed is controlled automatically to maintain the room temperature. When the Coal-trol Digital Thermostat is in Manual, the red Manual light is on, and the amount of fuel feed is controlled directly by the INCREASE or DECREASE pushbuttons. The room temperature will vary with the Manual setting and other factors, such as outdoor temperature, insulation etc. AUT 34 Feeder AUTO mode. Indication of feeder setting in percent. 0 to 99%. Feeder cannot be adjusted in Feeder Automatic Mode. MAN 65 Feeder MANUAL mode, Indication of feeder setting in percent. 0 to 99%. Feeder may be adjusted by using INCREASE or DECREASE pushbuttons.

Page 7 MENU Button Operation Round-robin Display Current Temperature Temperature Setting 72F D 73F Overview of the MENU items and their purpose. Current Time 1126A Starting from the Round-Robin display, each press of the will sequence through the displays below. D 700A Time of Daytime Temperature setting. See Day Temperature Setting for instruction on adjusting setting. D 70F Daytime Temperature setting. N 1000P Time of Nighttime Temperature setting. See Night Temperature Setting for instruction on adjusting setting. N 65F Nighttime Temperature setting. AUT 34 SETUP Stoker AUTO or MANUAL indication and fuel feeder percentage indication. Stove SETUP menu. See Automatic and Manual Stoker Control on page 6 for more information. See Stove SETUP in the Installation Manual for more information. After SETUP, the next MENU button press will return the display to the Time of Daytime temperature setting.

Page 8 Round Robin Temperature/Time Display DISPLAY NOTE Current Temperature 72F Temperature Setting D 73F Current Time 1126A The Round-robin display occurs automatically if the Thermostat is left alone for 30 seconds. (No button presses) "F" for Farenheit "C" for Celsius "D" for Daytime Temperature setting. "N' for Nighttime Temperature setting. "M" for Manual Temperature setting. "A" for AM "P" for PM Day Temperature Setting (Daytime Setback) D 700A Press MENU key until display shows Daytime Time setting. "D" on left of display) This is the time when the Daytime Temperature setting will occur. D 630A D 70F D 68F UP/DOWN button UP/DOWN button Press UP/DOWN buttons to set the time of day. Press and hold buttons to increase or decrease setting rapidly. When finished press. Press UP/DOWN buttons to set desired daytime temperature setting. When finished press. Press UP/DOWN buttons to set desired daytime temperature setting. When finished press. It can take an hour or more for the stove to change the actual room temperature from one setting to another. In this example, at 6:30 AM the thermostat will set the temperature to 68 F.

Night Temperature Setting (Nighttime Setback) Page 9 N 1000P Press MENU key until display shows Nighttime Temperature setting. "N" on left of display) This is the time when the Nighttime Temperature setting will occur. N 1130P N 71 UP/DOWN button UP/DOWN button Press UP/DOWN buttons to set the time of day. Press and hold buttons to increase or decrease setting rapidly. When finished press. Press UP/DOWN buttons to set desired nighttime temperature setting. When finished press. It can take an hour or more for the stove to change the actual room temperature from one setting to another. N 63F New nighttime temperature setting. When finished press. In this example, at 11:30 PM the thermostat will set the temperature to 63 F. Manual Temperature Setting (Setback Override) From the Round-Robin display you can temporarily change the current temperature setting. 72F D 73F 1126A M 65F Press UP or DOWN button. Display shows "M" and current temperature setting. UP/DOWN button M 72f Press UP/DOWN buttons to change temperature setting. Round-robin Display 72F M 73F 1126A The new temperature setting remains in effect until the time for the next programmed daytime or nighttime temperature setting. The Manual Temperature setting is indicated by the "M" indication of the current temperature setting.

One-Touch Feed Mode Page 10 72F AUTO/MANUAL button (2sec) FEED 5 4,3,2,1... Press and hold the AUTO/MANUAL button for two seconds. The display counts down from 5, once a minute until complete. Room Over-Temperature Cutout Use One-touch Feed once or twice after first starting a fire to help fill and even-out the grate. When complete, the thermostat will be left in the Stoker Control mode (Auto or Manual) it was in before the One-toch feed. (Refer to page 6) The temperature sensor in the thermostat has detected a room temperature above 95 F/ 35 C and has disabled the The MANUAL indicator light HiTemp Stoker motor, combustion air blinks every second. motor and the Convection Blower. If installed, the Power Vent motor continues to run. Init S 6:03P STOP CAUTION: Before proceeding, investigate the cause of the over-temperature condition. Displayed for 1 second. Current Time may be set if incorrect. The HI TEMP display may indicate a problem with your stove, chimney, or Coal-trol Digital System. The thermostat will not allow the to reset the thermostat until the room temperature is less than 95 F/ 35 C The red MANUAL indicator light blinks every second. Round-robin Display 94F D 73F 1126A The red MANUAL indicator light is On. The Coal-trol is in MANUAL Stoker Control. Refer to the Installation Manual for additional information.

Page 11 Coal-trol Digital Model 1- Specifications Note: Automation Correct LLC is constantly working to improve our products. For this reason, all specifications are subject to change without notice. Power Module: Electrical: Input Power FOR INDOOR USE ONLY 120VAC 60Hz, 1200W Fuse Output Power Stoker Convection Blower Igniter Combustion Blower Power Vent Mechanical: Dimensions Thermostat: Temperature: 10A 120V Fast, (IR10kA/125V), ABC-10A or Equivalent. 1A Continous, 2A MAX 4 A Continuous, 8A MAX 3A Continuous, 8A MAX 1.5A Continuous, 2A MAX 4.5A Continuous, 8A MAX All motors loads must be of the shaded-pole type. Combined Output Power 1200W MAX Displayed Precision Accuracy Electrical: Input Power Connection to Power Module Communication Connector Mechanical: Dimensions 6 1/2"L x 9"W x 2 1/2"H 16.5 cm L x 22.9 cm W x 6.35 cm H (With mounting bracket) Construction Environmental: 22 GA Galvanneal Complies with UL-873 Operating Temperature 113 F/45 C MAX Storage Temperature 40 F to 120 F Weight Approx. 3.5lbs/1.59Kg FOR INDOOR USE ONLY 1 F/1 C ±2 F/±1.8 C @ 68 F/20 C 8VAC, 2.5VA CLASS 2 RJ45 8PIN, 100ft Maximum (Standard Ethernet Straight Cable) RJ11 4PIN RS232 Serial, 9600,N,8,1. ASCII 3 1/4" L x 4 5/8"W x 1 3/4""H (8.25 cm L x 11.75 cm W x 4.45 cm) (With mounting bracket) Construction ABS Plastic, UL94V-0 Environmental: 95 F/35 C (Software Temperature Operating Temperature Shutdown Limited) Storage Temperature 40 F to 120 F Weight Less than 1 lb./0.45kg

Page 12 Syracuse NY www.automationcorrect.com Automation Correct LLC designs and manufactures technology products for home and industry. Combining over 75 years of practical experience, the Engineers and Technicians of Automation Correct LLC are dedicated to supporting our customers with innovative products. Copyright 2004, 2005 Automation Correct LLC. All rights reserved. Coal-trol Digital, Pelli-stat by Automation Correct LLC All others trademarks by the respective owners.