Plant Security & Fire Alarm Systems. HVAC Systems. Power Plants & Switchyards. Geographical Maps. Industrial Process Plants

Similar documents
X11CA COMPUTER ANNUNCIATORS

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

ESP TECHNOLOGIES LIMITED

Introducing the. Subklew SM24 Mosaic System

STATUS ALARM HISTORY ALARM RESET

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

INTELLIGENT FIRE ALARM CONTROL PANEL

Mark 25 Ultrapure Water Conductivity Analyzer

X16PDM P R O G RAMMABLE

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

M E A S U R E M E N T S D I V I S I O N

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

NLC C61 Air-Cooled Argon-ion Laser

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

Interscan Corporation. Instruction Manual Series Compact Portable Analyzer

Instructions for the 4-20mA Unit

Signaling Lights. SLC30-IPS Series Panel Mounted Annunciators

VT-3-1 VERTICAL THERMOFORMER

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Conventional Releasing Control Panel

GAS MONITOR Model Model

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

ESSEX ENGINEERING CORPORATION

NLC 210 Air-Cooled Argon-ion Laser

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

General Specifications for Lighted Crosswalk Warning Equipment and Miscellaneous Materials, Rev 4

DETECTION SYSTEMS. GCM Auto Alarm. Instruction Manual. GA0203P01 Rev. D

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

Model 4001 Series Single Channel Controller

! "! # Please read these installation and operating instructions completely and carefully before starting.

Soft Start Series MP700 Solid State, Reduced Voltage

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Across-the-Line SERIES MP300 Combined Manual and Automatic

Flexible Heaters. of Silicone Rubber & Kapton

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

CM800 Emergency Call System

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

SEC Signature Process Gas Analyzer

Product Specifications MaxLumen MRI LED Diffused Lighting

1022 R/T Remote Monitor

Ronan Model X96S Series Weighing System

Product Specifications MaxLumen MRI LED Diffused Lighting

Ronan Model X96S Series Density System

EXTINGUISHING AGENT RELEASE MODULE

VA301C CONTROLLER WITH BACnet OPTION

Flame Simulator User Manual. Publication Rev. A

RAM3 Remote Alarm Module

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

For Complete Fire and Gas Solutions

Fill Point, Level Gauges, and Control Range

DGC-500 DIGITAL GENSET CONTROLLER

Variable Frequency Drive SERIES MP800 VFD

Controllers, Indicators & Set Point Programmers

SECTION AUTOMATIC TRANSFER SWITCHES

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

Instructions for the 4-20mA Unit

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

DETCON MODEL SW-AV1-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

ADDITIONAL INFORMATION

PodView Level Indicator LI40 Series Manual

Solid State LED Annunciators

Ethernet General Purpose

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

NETWORK FIRE ALARM CONTROL PANEL. Features

HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

ELP21LU3-LF-HLOL THREE CHANNEL

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

Mounting Plate ADA/HOSPITAL SIGNALING DEVICES 14-8 FEATURES. > Momentary switch push button > Stainless steel faceplate

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

OPERATION MANUAL MODEL & ACCELEROMETER

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual

IC6-B, IC6-MB, IC6-BB, IC8-B, IC8-MB, IC8-BB, ICA6-B, ICA6-MB, ICA6-BB, IC6DVC-B, BS650 ICS6-MB, ICS8-MB

CO Guardian LLC Document No E. AIRPORT DRIVE Date: TUCSON, AZ CO Guardian LLC 1951 E. Airport Dr.

NT DUAL CHANNEL DISPLAY. User Guide

DETCON MODEL SW-AV2-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

Safety, Installation, and Operation Manual

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

CURRENT LIMITING LIGHTING CONTROL PANEL Supplemental Overcurrent Protection City of Los Angeles Approved Version

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

Digital Electronic Thermostat With RF

CN7232 Advanced Garage Ventilation Controller

Model A1600 Series Annunciator

Digital Electronic Thermostat With RF

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

EVD-1 Installation, Operation, and Instruction Manual

American Railway Engineering and Maintenance of Way Association Letter Ballot. Draft

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

Mini rad-d User's Manual - February 22, 2010

Transcription:

Plant Security & Fire Alarm Systems HVAC Systems Power Plants & Switchyards 2 The Ronan Series X71 Mosaic Graphic System is ideally suited for the graphic display of industrial processes, power distribution networks, security and fire alarm of buildings in aerial layout, airport runways and luggage handling facilities, etc. The graphic layout generally includes status or alarm LED indication, selector and push-button switches, analog meters, digital and bargraph readouts, annunciators and time clocks, etc. The X71 Mosaic Graphic is best suited where applications require frequent modifications due to plant expansions or process changes. The surface of the mosaic tiles is silk-screened or engraved with the customized layout depicting the process or facilities. The panel or wall mounted graphic provides for a very functional and aesthetically pleasing process or facility annunciator/control system. High Strength Structural Mounting Frame 1 (25.40 mm) and 2 (50.80 mm) Square Tiles Multicolor Split Indicators Conventional and Serial Input Annunciators Smaller and Larger Depth Frames Available Large Number of Colors Available Through or Behind Tile Indicators FEATURES Lamp Displays Glass Filled Nylon Grid for Maximum Strength Translucent Tiles for Rear-Lit Symbols Multifunction Switches and Push Buttons Custom Equipment Integration Multicolor Process Lines Outlined and Non-Outlined UL Listed Geographical Maps Industrial Process Plants Water Treatment & Power Plants Power Distribution Networks Information Systems & Data Highway Gas Distribution Plants Mass Transit & Subway Systems Three Dimensional Plant Layouts Airport Luggage Handling Facilities Material Handling & Conveyor Systems Emergency Power Switching Systems Traffic Control Metering

M O S A I C T I L E S A N D G R I D The grid and tile construction allows the highest flexibility in regard to overall sizing, modification of display layout and addition or omission of indicators, control devices, and equipment without the use of special tools or training. The tile assembly is customized to the specific requirement of an application in multiples of a single tile size increment. The grid is supported from the peripheral framework and cross beam structure for maximum stability. The graphic assembly is installed through a single panel cutout of the control panel and secured with clamps provided. F r o n t V i e w R e a r V i e w TILES AND GRID MATRIX The high precision 12 x 12 (304.80 mm x 304.80 mm) standard grid is molded from glass-filled nylon 6/6 flameretardant 94V-0 material. The grid is cut in 1 (25.40 mm) increments and is assembled to meet size requirements. The tiles are molded from polycarbonate flame-retardant 94V-0 material and are selfextinguishing, highly resistant to ultraviolet rays, and meet ASTMD648 heat deflection temperatures of 280 F. The tiles are available in 1 x 1 (25.40 mm x 25.40 mm) and 2 x 2 (50.80 mm x 50.80 mm). The two sizes may be mixed on the same grid, with 2 x 2 (50.80 mm x 50.80 mm) tiles suitable for larger graphics. 3

G R A P H I C L A Y O U T DOCUMENTATION The graphic layout is best transferred via computer file. If not available, an actual size drawing will reduce customer approval time for layouts. Ronan factory personnel will verify compliance with tile and grid layout requirements and optional mounting facilities for special equipment. The customer is requested to select the color for lines, symbols, and tile background from the color chart. (See back page) LINES The process line width should be selected based on the graphic s overall size and is available outlined or not outlined (solid). Care should be taken in the selection of color for contrast in text/process outlines. HI-LO PRESSURE MOSAIC Mechanical Closet 321.1 ARCHITECTURAL TEXT/LETTERING The recommended standard lettering style is gothic, with many other computer generated styles available. The letters should be sized for easy readability by the operator. Recommended sizes are from 7/16 (11.11 mm) to 1/2 (12.70 mm) high. The lettering is centered on symbols or tiles with adjustments to minimize screening across tile separation. PU-801 1600AF 1600AT 4 SYMBOLS AND CUSTOM LOGO A large number of standard symbols is available. These can be sized to fit on a single tile or a number of tiles and placed symmetrically for the best visual appearance. The standard symbols are available from Ronan on Auto CAD files to simplify the graphic layout for the customer. Custom symbols may be generated for specific applications, including customer s logo in the graphic layout. AUTO RUNNING MANUAL 200A PROTECTIVE COATING The final graphic display is coated with a nonglare UV resistant acrylic spray for a long-lasting, soil resistant appearance. The protective coating allows for cleaning with mild cleaners or soap solution. M

L I G H T S A N D S W I T C H E S INDICATOR LIGHTS All indicator lights utilized are LED type (Light Emitting Diodes) with current limiting to provide greater than 100,000 hours of life. The indicators are available in through-the-tile or behind-the-tile versions. THROUGH THE TILE Typical through-the-tile LED indicators are available in various diameters and light intensity. The size of the indicators should be based on the size and density of the graphic. Single or dual color indicators available. If the customer does not state a preference, Ronan will select the appropriate type, based on the client s application. BEHIND THE TILE The Ronan Series X71 LED indicator is a 1 x 1 (25.40 mm x 25.40 mm) assembly which attaches to the grid from the rear behind a translucent tile. The translucent tile is typically screened with a process symbol or outline. The X71s are available in single or multiple colors (up to 3 colors), e.g. green, red or amber. The three colors are typical for motor or valve status indication. PUSH BUTTONS Push buttons are available in many different sizes and may occupy a single tile or multiple tiles. The number of poles and contact ratings are application based and must be specified by the customer. Illuminated (LED type) and non-illuminated push buttons are available with round, square, and rectangular buttons. Momentary or ON/OFF functions with single or multi-poles are available. SWITCHES Proper selection of switches should be made by the customer based on the application, taking into consideration power requirements, number of poles, positions (maintain or spring return), actuator (key or handle), and size. Ronan s product specialists are available for technical support. 5

A N N U N C I A T I O N A N D P R O C E S S P A R A M E T E R D I S P L A Y S SERIAL INPUT ANNUNCIATORS ANNUNCIATORS The X71 graphic may include conventional window annunciators mounted into the grid with special mounting facilities. Due to the annunciators inherent heavy weight, there are limitations to their size. For applications where large numbers of windows are required, a combination of lamp cabinet, incandescent or LED type, with remote annunciator logic is recommended. The most suitable approach for a larger number of windows or indicators is to utilize the Ronan X110 Serial Input Annunciator Controller driven from a host such as a PLC, Ronan X120 Field Multiplexer, or an X500E Sequence of Events Recorder. Each X110 controller provides for 48 outputs with individually selectable alarm sequence per output. The X110s are typically mounted in the graphic enclosure or integral to the rear of the graphic assembly. D I G I T A L / A N A L O G M E T E R S A N D D I S P L A Y S DIGITAL DISPLAYS/BARGRAPHS Digital Indicators are available in many sizes and should be selected based on the application. Typical requirements are AC or DC currents and voltage, Watt and VAR, frequency, time clock, and process loop indicators. Typical indicators come with different size LEDs or LCDs, with any number of digits as specified by the customer. Digital Indicators typically span multiple tiles with Ronan providing custom mounting facilities. Bargraphs can be utilized as process value indicators with 4-20 ma input and are available with single or dual channel LED display, with digital indicators optionally. The bargraphs may be horizontally or vertically mounted onto Ronan supplied plates. 6 ANALOG DISPLAYS Analog Meters for specific custom requirements can be supplied. Selection should be made by the customer with Ronan to supply special mounting plates sized to the meter s dimensions.

S P E C I F I C A T I O N S MECHANICAL The X71 Mosaic Graphic System is assembled from 12 x 12 (304.80 mm x 304.80 mm) reinforced fiberglass matrix grids to the customer s specified size. The assembled grids are mounted into a heavy steel frame with cross beam support on each corner of each 12 (304.80 mm) matrix grid. The steel frame is selected from the two available depths based on the overall size of the graphic. The accurate panel cutout dimensions are supplied with the process layout approval drawings to allow preparation of the control or display panel. MOUNTING The X71 graphic assembly is fed through the panel cutout from the front of the panel and clamped from the rear with the furnished removable clamp assemblies. The maximum panel thickness allowed with the standard clamping assemblies is 1 (25.40 mm). Clearance behind the graphic is based on the depth of the custom equipment mounted in the graphic as well as optional termination facilities, connectors, or serial input annunciators. A Overall A Overall B Cutout A Overall B Cutout H Graphic Width 3.65" (92.71 mm) H Graphic Height A Overall = Graphic H or W x.0015 (.0381 mm) + Graphic H or W + 1.50 (38.10 mm) B Cutout = A Overall.62 (15.75 mm) B Cutout A Overall B Cutout A 5.65" (143.51 mm) H Graphic Height A ELECTRICAL The indicators, control switches, push buttons, parameter displays, or other equipment required may be factory wired to terminals mounted to the rear of the mechanical structure. The indicators and/or window type lamp cabinets may be controlled from conventional solid state alarm logic or X110 Serial Input Annunciator Controller(s). The X110 may be integral mounted to the rear of the graphic and factory wired to the indicators. Optionally, Ronan may provide multiconductor cables wired to the indicators in the graphic, and multi-pin connectors for interface to the remote mounted X110 controllers..38" (9.65 mm) Maximum Thickness Mounting Panel Frame Extrusion Tile Grid H Graphic Width Mounting Clamp Assembly Maximum 12.00" (304.80 mm) Spacing Detail A SPECIAL ENCLOSURES 7 The X71 graphic may be mounted into custom fabricated enclosures. The enclosures are manufactured from stainless steel or from cold-rolled steel and painted to customer specified color. They are sized to accommodate the graphic, termination facilities and/ or serial input annunciator controllers.

O R D E R I N G I N F O R M A T I O N Color and number selector for symbols and flow lines 100 164 103 165 104 132 106 133 108 134 109 135 114 137 115 138 116 166 117 136 118 139 161 140 162 141 163 142 119 143 120 146 121 144 122 145 123 147 127 150 124 152 125 153 126 154 129 155 130 159 131 160 Complete the information below when ordering your X71 Mosaic Graphic Layout Size: Height Inches (mm) Width Inches (mm) Tile Size: 1 x 1 (25.40 mm x 25.40 mm) 2 x 2 (50.80 mm x 50.80 mm) Tile Color: Beige White Light Gray Charcoal Gray Process Layout: Sketch Drawing Auto Cad 5 Colors or Less Additional Colors Indicators: Through Tile, Number of LEDs Behind Tile, Number of Assemblies (Standard Voltage 24 Vdc, Current 20 ma. Other Lamp Voltages Available) Number of Clocks Number of Lamp Cabinets Size Number of Annunciators Size Serial Input Annunciator Controller X110 (48 Outputs per Unit) Terminals: Weidmueller SAK2.5 Terminals with Dual Gating Diodes: Weidmueller DK4D (Required for Lamp Test) Analog Display, Model No. Bargraphs, Model No. Digital Display, Model No. Push-Button and Rotary Switches: Number of Switches Number of Poles Number of Positions Voltage Current Requirement T H R E E Y E A R W A R R A N T Y Ronan warrants equipment of its own manufacture to be free from defects in material and workmanship, under normal conditions of use and service, and will repair or replace any component found to be defective, on its return, transportation charges prepaid, within three (3) years of its original purchase. This warranty carries no liability, either expressed or implied, beyond our obligations to replace the unit which carries the warranty. RONAN ENGINEERING COMPANY Display Products Division 21200 Oxnard Street, Woodland Hills, CA 91367 U.S.A. 800-327-6626 Fax 818-992-6435 1 Tilley Road, Crowther Industrial Estate, Washington, Tyne & Wear U.K., NE38 OAE 191-416-1689 Fax 191-416-5856 32 Bermondsey Road, Toronto, Ontario, Canada M4B 1Z5 416-752-0310 Fax 416-752-8072 http://www.ronan.com E-Mail: sales@ r onan.com X71 Rev.1 08/01 Printed in U.S.A.