3M Novec 1230 Fire Protection Fluid For Marine Applications. Created. Life. for

Similar documents
3M Novec Fire Protection Fluid

How can I protect invaluable assets and the environment from the effects of a fire?

DuPont FE-25 FIRE EXTINGUISHANT. Preferred Replacement for Existing Systems and the Choice for New Applications

Fire suppression systems for server rooms and data centres

FIRE SUPPRESSION SYSTEM

MINIMAX FIRE PRODUCTS WHITE PAPER THE COST-BENEFIT ADVANTAGES OF REPLACING HALON WITH 725 PSI MX 1230 CLEAN AGENT FIRE SUPPRESSION SYSTEMS

KD Innovative extinguishing with Novec TM 1230 by 3M TM

Guidance Note EC Regulation No 842/2006 on Certain Fluorinated Greenhouse Gases. BFPSA Guidance for the Fire Protection Industry

BOC FS125 The Fire Extinguishing Solution

Ammonia. Background on ammonia as a refrigerant

C L E AN A G ENT FIRE SUPPR E SSIO N S Y S T E M S

CERTIFICATE OF FIRE APPROVAL

ASSEMBLY 37TH SESSION

Safe, Effective, Environment-friendly

SAPPHIRE. Gaseous Fire Suppression Systems. Delivering 3M Novec 1230 Fire Protection Fluid

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

Identify RISKS. Design SOLUTIONS. Prevent DISASTERS

The Sensible Solution to a global dilemma

Superior by Design The Kidde ADS TM FM-200 System

Bridge to Splice Presser 710-BSP

Making equipment decisions

Clean, Silent and Efficient Refrigeration Solutions for Distribution and City Operations

How can you minimize consequential damages in case of a fire?

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Creating a safer world!

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

Effectively Managing the Transition to Lower GWP Refrigerants

IMO LIST OF DOCUMENTS ISSUED IN CONNECTION WITH THE FORTY-SEVENTH SESSION OF THE SUB-COMMITTEE ON FIRE PROTECTION AGENDA FOR THE FORTY-SEVENTH SESSION

ODS & SGG Alternatives for the Fire Protection Industry 2018

3 Scotch Mini-Weld Adhesive System User s Manual

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

Installation Manual February Opticom Infrared System. Model 575 Confirmation Light Kit

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

Duct Mount. Installation Instructions

FIRE SUPPRESSION SOLUTIONS

Welcome to Argonite fire protection from Ginge-Kerr

GX-20/FM-200 Fire Extinguishing System

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

Fire Protection in the Mining Industry. Garry Kwok Board Member

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

tyco Fire & Safety RESEARCH VESSEL - NEW ORLEANS

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

Installation Manual September Opticom Infrared System. Model 798 Emitter Bezel Mount Kit

Legislation & Standards

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

CHAPTER 1 INTRODUCTION

Global Marine Solutions. From Ship to Shore, single source providers for Fire Protection, Electronic Security, Life-Safety and Communications Systems

Technical Bulletin April Opticom Infrared System. Optical Preemption Detector Identification Guide

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

Information Guide Maintenance and Refrigerant Regulations. Issue 35

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

The Problem of Counterfeit Refrigerants

Design Criteria. Installation

Duct Temperature Sensors

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

Featuring... ASZ16 UP TO 16 SEER. ASZ16 Heat Pump

Global Requirements for the Fire Protection of Ships. Dr Janet Murrell Warrington Certification Ltd

Guided Learning Hours (GLH) 4 Invigilated Assessment (IA) 1 Total Qualification Time (5)

ODS Licensing System. Information Document

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

An Overview of Extinguishing Systems for Computer Equipment

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

1.5 L Electric Kettle

HFC-227ea FIRE SUPPRESSION SYSTEM

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

FPA Australia submission to the review of the Ozone Protection and Synthetic Greenhouse Gas Management Act 1989 and associated legislation.

Detection System Model 3500 Series

First Line of Safety: Farris Engineering

3M Benchtop Air Ionizer 963E. User s Guide

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

"ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range

OZONE LAYER PROTECTION ACT 1996

BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT

Mitsubishi Electric Guide to Chiller Technologies. Information Guide 58

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Leading. Click to edit Master subtitle style. 3M Fire Protection Products Awareness & Introduction to 3M Fire Protection Products

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

Duct Humidity/Temp Sensor

UNIFIED INTERPRETATION OF PROVISIONS OF IMO SAFETY, SECURITY, AND ENVIRONMENT-RELATED CONVENTIONS

Instruction Manual: IM E. Installation and Operation Manual for Powerware PVL 50, 80, 100, 120, 160, 200 KA

PROCEDURES FOR APPROVAL OF LIFE-SAVING APPLIANCES AND FIRE SAFETY SYSTEMS, EQUIPMENT AND PRODUCTS

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

Guidance for Stationary Refrigeration & Air-Conditioning

Global Marine Solutions and Services From Ship to Shore Single Source Providers for Fire, Security, Life Safety

Government of Bermuda Bermuda Shipping and Maritime Authority BERMUDA SHIPPING NOTICE

IMO FP 53 Report. Lloyd s Register report on the 53 rd session of IMO Fire Protection Sub-Committee. 16 th March, 2009

Transcription:

3M Novec 1230 Fire Protection Fluid For Marine Applications Created for Life

3M Novec 1230 Fire Protection Fluid For Marine Applications When matters safety most 3M Novec 1230 Fire Protection Fluid is an advanced, next-generation halon and CO 2 replacement, offering a number of important advantages over other clean agents and CO 2 in marine applications. The product is based on a proprietary chemistry from 3M. Its low acute toxicity, combined with high extinguishing efficiency, gives Novec 1230 fluid the widest margin of safety among all other chemical clean agents and CO 2 even at relatively high extinguishing concentrations. This makes Novec 1230 fluid ideal for occupied spaces, including engine and pump rooms, paint lockers and communication and control centers where personnel may be exposed to the agent upon system discharge. Novec 1230 fluid vaporizes rapidly during discharge, and it is non-corrosive and non-conductive, so it will not harm delicate electronics, radar, navigation and other equipment. And, unlike foams and powders, it leaves no residue to clean up, which means that operations can continue without interruption. The bottom line? With Novec 1230 fluid, you get fast, effective fire protection without compromising ship systems, the safety of passengers and crew, or the environment. 2

The long-term, sustainable solution From its initial development, 3M Novec 1230 Fire Protection Fluid was designed to address the global demand for a halon or CO 2 replacement that is safe, effective and not subject to current or anticipated regulatory restrictions, nor scheduled or targeted for future phaseout. With zero ozone depletion potential, short atmospheric lifetime and a global warming potential of 1, Novec 1230 fluid has proven to be the first chemical halon replacement to offer a viable, long-term, sustainable solution for marine fire protection. 3M Novec 1230 Fire Protection Fluid Environmental Properties Properties Novec 1230 HFC-125 HFC-227ea HFC-23 Ozone Depletion Potential (ODP) 1 0.0 0.0 0.0 0.0 Global Warming Potential IPCC 2 1 3500 3220 14800 Atmospheric Lifetime (Years) 0.014 (5 days) 29 34.2 270 1 World Meteorological Organization (WMO) 1998, Model-Derived Method. 2 Intergovernmental Panel on Climate Change. (IPCC) 2007 Method, 100 Year ITH, CO 2 = 1. Why is sustainability important to consider? Global Warming Potential 14000 12000 10000 8000 6000 4000 2000 Novec 1230 Fluid In recent years, concerns about environmental issues especially those relating to climate change have led to increasing regulatory scrutiny of compounds with high global warming potentials. These greenhouse gases include several conventional halon and CO 2 replacements, such as HFCs. Under the Kyoto Protocol and other international agreements, more and more industrialized nations have committed to reducing the amount of greenhouse gases emitted to the atmosphere. Although the use of HFCs in fire protection is still allowed today, there is growing concern about their future viability, as regulators look for industries and applications (such as fire protection) where alternatives exist to reduce greenhouse gas emissions, without harming economic growth. Removal of HFCs from fire protection applications is one strategy that companies can employ to reduce their overall emissions from the basket of six greenhouse gases identified by the Kyoto Protocol. Given the inevitability of HFC regulations in the U.S, EU, and across the globe, companies are also contemplating the costs and business disruption associated with future restrictions on the use of HFCs in fire protection. Ultimately, a growing number of end-users are concluding that long-term economics as well as good stewardship favor the use of sustainable solutions, such as Novec 1230 fluid. Environmental Footprint Comparison Halocarbon Compounds HFC-125 HFC-23 HFC-227ea Halon 1301 0 0 2 4 6 8 10 12 14 Ozone Depletion Potential Area of the circle is proportional to the atmospheric lifetime of the compound. 3

3M Novec 1230 Fire Protection Fluid For Marine Applications The Widest Margin of Safety Because 3M Novec 1230 Fire Protection Fluid offers a much wider margin of safety than other halocarbon agents, its effective use concentration will not exceed safety limits in marine applications. 3M Novec 1230 Fire Protection Fluid Safety Margin-Class B Hazards Agent Novec 1230 HFC-125 HFC-227ea Inert Gas CO 2 Use Concentration 1 4.2-5.9% 8.7-12.1% 6.25-8.7% 34.2-40.6% 30-75% NOAEL 2 10% 7.5% 9% 43% <5% Safety Margin 69-138% nil 3-44% 6-26% Lethal at design concentration 1 2008 NFPA 2001 and NFPA 12 2 NOAEL for cardiac sensitization (halocarbons) and effects specific to CO 2 It s important to note that the complex geometry of engine rooms, communications centers and other shipboard locations makes it difficult to calculate their net volume accurately; such calculations are used to determine an effective (but safe) agent design concentration. If a significant portion of a room is filled with piping, conduits, machinery and other obstructions, agent concentration could quickly exceed its NOAEL (No Observable Adverse Effects Level), if the system was designed for the volume of room when it is empty. With Novec 1230 fluid, you get the stopping power you need to extinguish fires in obstructed spaces without putting people at risk.* *Industry standards require egress from a protected enclosure prior to system discharge 4 Inert gas /CO 2 Novec 1230 fluid Engineered for fast extinguishment 0 = Fire detection Performance you can depend on In numerous laboratory and field tests around the world, witnessed by independent agencies, 3M Novec 1230 fluid has proven its effectiveness in marine flooding applications. Consequently, fire protection systems incorporating Novec 1230 fluid, developed and sold by the world s leading systems manufacturers, have been registered and certified by a growing number of marine approval authorities (see list on next page). 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Agent flow time Time (seconds) Fire extinguished Novec 1230 fluid knocks down fires in about one quarter the time of inert gas/co 2 agents. Fast extinguishment helps keep fires small, giving them less chance to spread. For example, fixed fire protection systems using Novec 1230 fluid have successfully completed test protocol IMO MSC Circular #848. This protocol tests the ability of a system to extinguish effectively a variety of fires in total flooding applications. The fires occurred in a 500 m 3 test enclosure, simulating machinery rooms and pump rooms, and were witnessed by agents from Underwriters Laboratories, the U.S. Coast Guard, Lloyd s Register and the United Kingdom s Maritime and Coastguard Agency (MCA).

The viable proven solution Regulatory Status Novec 1230 fluid complies with chemical notification requirements in the following regions: United States Europe Australia Canada Japan China Korea Subsequently, systems using 3M Novec 1230 Fire Protection Fluid have received the Certificate of Type Approval from the MCA, indicating that these systems are accepted and in compliance with the requirements of: The Merchant Shipping Regulation 1998, S.I. 1012. The Merchant Shipping Regulation 1998, S.I. 1011. 1978 SOLAS Protocol as amended by the SOLAS amendments to date. HSC Code - Resolution MSC.36(63). The Code of Practice for Safety of Large Commercial Sailing & Motor Vessels. The International Maritime Organization MSC/Circ.848. Fire suppression systems using Novec 1230 fluid have been successfully submitted by their manufacturers for certification by marine approval authorities around the world: UK MCA RINA, Italy LRS Type Approval DNV Type Approval Bureau Veritas Type Approval UK Module B Polish Registry of Shipping Australian Coast Guard Marine Marchand Approval Dutch Shipping Authority Acceptance, Inland & Sea Belgium - Inland and Sea going Acceptance Icelandic Registry of Shipping American Bureau of Shipping (International) Canadian Coast Guard Korean Registry of Shipping Germanische Lloyds U.S. Coast Guard 5

3M Novec 1230 Fire Protection Fluid For Marine Applications Note: Before using this product, please read and follow the precautions and directions for use in the Material Safety Data Sheet, product label and manufacturer guidelines for refilling systems. Easy handling, easy storage 3M Novec 1230 Fire Protection Fluid is an excellent choice for engine and equipment rooms, and other normally-occupied areas of pleasure craft and high-speed craft. Because it is a liquid at room temperature, and stored at low vapor pressure, agent handling and charging of systems using Novec 1230 fluid is greatly simplified, and can be accomplished without moving the cylinders offsite saving you time, and ensuring uninterrupted protection of your assets. Because the liquid is shipped non-pressurized, refilling after discharge is a straightforward procedure. The liquid state of Novec 1230 fluid also allows for efficient use of space, requiring about the same number of cylinders as conventional halocarbon agents and many fewer cylinders than inert gas or CO 2 systems. Unlike high-pressure alternatives, the product can be shipped safely by air in bulk quantities, classified as non-hazardous and, thus, without restrictions. Upgrading an existing fire protection system can be accomplished by reusing the existing system control equipment with the newly installed system designed for use with Novec 1230 fluid. Compatible with fire system materials Novec 1230 fluid has been shown to be compatible with typical materials of construction used in fire suppression systems, including stainless steel, carbon steel, aluminum, brass and copper. The material is stable and noncorrosive in end use. Long-term testing has demonstrated excellent compatibility with various elastomers used in o-rings, gaskets and other types of seals. Note: However, we recommend that the product not be used with fluoroelastomers, because they are both fluorine-based with an affinity for each other and, therefore, should not be used together. 6

3M Blue Sky SM Warranty 20-year protection against regulatory bans or restrictions on the use of 3M Novec 1230 Fire Protection Fluid When it comes to environmental regulations, 3M gives you a clear advantage Today s world is full of changes designed to help ensure a better tomorrow. But managing the risks created by these changes is challenging. Fortunately 3M understands your challenges and has the answer you re looking for with the 3M Blue Sky SM Warranty. Here s how it works: if Novec 1230 fluid is banned from or restricted in use as a fire protection agent due to ozone depletion potential or global warming potential, 3M will refund the purchase price of the fluid. That s a promise and performance you can take to the bank. For complete details on this program, please contact your 3M representative, or visit www.3m.com/novec1230fluid The high global warming potential and atmospheric persistence of halon replacements such as HFCs are leading to concerns about whether their use will continue to be permitted. For example, F-Gas Regulations that have been introduced in Europe impose requirements specific to HFCs for technician training, inspections, testing, and reporting. It is likely that HFCs may follow the halon extinguishing agents that were so popular until the 1990s, when they became restricted, and are now banned from being manufactured and are being phased out in end use. Measures addressing the use of HFCs are also being drafted in the USA. The U.S. House of Representatives has passed legislation that would phase down the production of HFCs. Similar measures are being considered at an international level. For example, proposals have been advanced to phase-down HFC production under the Montreal Protocol. In addition, an early action item identified under the California Global Warming Solutions Act of 2006 includes a consideration that, from 2012, all new fire protection systems in California must use an agent with a global warming potential below a minimum threshold level. The California Air Resources Board (CARB) proposal and U.S. House bill reflect the regulators concern that, while emissions from this sector are currently low, the installation base is growing quickly and the emission potential of this installed base represents a significant future liability. Thus, the only meaningful way to limit this future liability is to reduce the use of HFCs. That s why 3M offers you the peace-of-mind made possible by our exclusive 3M Blue Sky SM Warranty. 7

3M Novec 1230 Fire Protection Fluid For Marine Applications 3M Resources 3M Novec 1230 Fire Protection Fluid is supported globally by 3M sales, technical and customer service resources, as well as by authorized fire suppression system manufacturers (OEMs). For more information, please visit our web site: www.3m.com/novec1230fluid The 3M Novec Brand Family The Novec brand is the hallmark for a variety of patented 3M products. Although each has its own unique formula and performance properties, all Novec products are designed in common to address the need for safe, effective, sustainable solutions in industry-specific applications. These include precision and electronics cleaning, heat transfer, fire protection, lubricant deposition and several specialty chemical applications. 3M Novec Engineered Fluids 3M Novec Aerosol Cleaners 3M Novec 1230 Fire Protection Fluid 3M Novec Electronic Coatings 3M Novec Electronic Surfactants United States 3M Electronics Markets Materials Division 800 810 8513 China 3M China Ltd. 86 21 6275 3535 Europe 3M Belgium N.V. 32 3 250 7521 Japan Sumitomo 3M Limited 813 3709 8250 Korea 3M Korea Limited 82 2 3771 4114 Singapore 3M Singapore Pte. Ltd. 65 64508888 Taiwan 3M Taiwan Limited 886 2 2704 9011 Product Use: All statements, technical information and recommendations contained in this document are based on tests or experience that 3M believes are reliable. However, many factors beyond 3M s control can affect the use and performance of a 3M product in a particular application, including conditions under which the product is used and the time and environmental conditions in which the product is expected to perform. Since these factors are uniquely within the user s knowledge and control, it is essential that the user evaluate the 3M product to determine whether it is fit for a particular purpose and suitable for the user s method of application. Warranty and Limited Remedy: Unless stated otherwise in 3M s product literature, packaging inserts or product packaging for individual products, 3M warrants that each 3M product meets the applicable specifications at the time 3M ships the product. Individual products may have additional or different warranties as stated on product literature, package inserts or product packages. 3M MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY ARISING OUT OF A COURSE OF DEALING, CUSTOM OR USAGE OF TRADE. User is responsible for determining whether the 3M product is fit for a particular purpose and suitable for user s application. If the 3M product is defective within the warranty period, your exclusive remedy and 3M s and seller s sole obligation will be, at 3M s option, to replace the product or refund the purchase price. Limitation Of Liability: Except where prohibited by law, 3M and seller will not be liable for any loss or damage arising from the 3M product, whether direct, indirect, special, incidental, or consequential regardless of the legal theory asserted, including warranty, contract, negligence or strict liability. 3 Electronics Markets Materials Division 3M Center, Building 224-3N-11 St. Paul, MN 55144-1000 www.3m.com/novec 1-800-810-8513 Please recycle. Printed in USA. Issued: 12/09 3M 2009. All rights reserved. 6930HB 98-0212-2651-3 3M and Novec are trademarks of 3M Company. Used under license by 3M subsidiaries and affiliates.