PSJR /PSSR Models. NOTE: The document is to be used in conjunction with the Dinex s Perfect Serv Operation Manual

Similar documents
Wax Base Heater & Dispenser

Installation & Operation Manual

INSTALLATION and OPERATION INSTRUCTIONS

Installation & Operation Manual

INSTALLATION and OPERATION INSTRUCTIONS

Service Manual Models CPH2 & CPH3

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

Operation Manual and Parts Directory

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

HEAVY DUTY RANGE BAIN MARIES & HOTCUPBOARDS (ELECTRIC)

INSTALLATION and OPERATION INSTRUCTIONS

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

Instruction Manual. Portion Cup Cheese Warmer

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

CC-2222C-PL, CC-2222C-PRL, CC-2222C-PR-2, CC-2222C-PL-2,

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

COMFORT PACK INSTALLATION AND MAINTENANCE INSTRUCTIONS

Owner s Manual STOVES. MODELS 620 Kitchenaire. 621 Kitchenaire 711S

Installation & Operations Manual. Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800) REV: LN PN

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

InstructIon Manual KrEs EQuIPMEnt stands

Installation & Operations Manual Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800)

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

DISHWASHER - PART RECOGNITION GUIDE

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

Operation Manual and Parts Directory

Bx OVEN SET UP AND OPERATION OF OVEN AND CONDENSER UNIT (IF FITTED) CLASSIC

Quality Refrigeration OWNER S MANUAL. Instructions for the installation, operation and maintenance of Traulsen: Heated Banquet & Transport Carts

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

CHEF BASE CABINETS Installation, Operation and Maintenance Instructions

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

OPERATING AND MAINTENANCE MANUAL

55CM Wide Freestanding Under Counter Freezer Instruction Manual

OPERATIONS FOOD HOLDING & TRANSPORT CABINETS. wîttco foodservice. equipment

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

Installation & Operations Manual for. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers. 4/17 Rev.

BLG-HGP Model Bottom Mounted Full-Length Swing Glass Door Freezer Merchandisers

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

WCPT-3 and WCPT-4. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE. Drop-in Display Cases

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC Directives for the voltages stated on the data plate.

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

User Manual / Installation Instructions

Installation & Service Manual

RETAIL MERCHANDISING UNITS

Installation & Operations Manual for R-290 SERIES. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers 2/

Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug. Instruction Manual.

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS

Installation & Service Manual

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

CHEF BASE CABINETS Installation, Operation and Maintenance Instructions

Preparing the Cabinet

OWNER S MANUAL MODEL BW4B SLICER WARMER

VIKING RANGE CORPORATION, P.0. DRAWER 956, GREENWOOD, MS. USA

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

E25 CONVECTION OVEN E25MS CONVECTION OVEN SERVICE MANUAL

STRATA BY INSTRUCTION MANUAL WARRANTY CERTIFICATE

INSTRUCTIONS MODEL: P9EO

INSTALLATION AND OPERATION INSTRUCTIONS STANDARD BACK BAR COOLERS, SELF CONTAINED MODEL NOS.

MANUAL FOOD HOLDING & TRANSPORT CABINETS WITTCO MODEL NUMBERS

GCG-26c. Instruction Manual. G-Series Cooler

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

OPERATIONS MAINTENANCE MANUAL

APARTMENT MAINTENANCE SERIES

SPX SERIES PACKAGED AIR CONDITIONING/HEAT PUMP UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Spare Parts Catalogue MV1006

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

MODEL DESCRIPTION PART NO.

High Profile Evaporator

OPERATING INSTRUCTIONS

Cincinnati, OH USA

Installation and Operation Guide For

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Cheese Display Case. Instruction Manual Model #5580BV2 and Model #5580BV3 Model #5582 and Model #5583. Cincinnati, OH USA.

52 STRATHMERE CEILING FAN

Product & Assembly Manual

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Optimax Refrigerated Retail Merchandisers

OWNER S MANUAL FINLEY FIREPLACE. Product code: UPC code: Date of purchase: / /

RCM-77. Instruction Manual. G-Series Cooler. Manual is for the following model: RCM-77-N23EB. U.S. Patent No. 8,215,125 RECHARGEABLE COLD MERCHANDISER

ALUMA WET BY INSTRUCTION MANUAL WARRANTY CERTIFICATE

Instruction Manual. Astro Staging Cabinet

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

BMG-HGP & BMG-SLP Model Bottom Mounted Full-Length Glass Door Refrigerator Merchandisers

Replacement Parts List For Models COS-20G

Optimax Refrigerated Retail Merchandisers

Installation and Operations Manual for HORIZONTAL DISPLAY MERCHANDISERS

Installation & Operations Manual

COUNTER TOP REFRIGERATION MODEL SERIES HUBM-2RB/HUBM-2FB/HUBM-3.5RB/HUBM-3.5FB HUBM-2R/HUBM-2F/HUBM-3.5R/HUBM-3.5F

IMPORTANT: RETAIN FOR FUTURE REFERENCE

THE CHATEAUX 52"/60" UNI PACK CEILING FAN INSTALLATION INSTRUCTIONS

SUNSEEKER BY INSTRUCTION MANUAL WARRANTY CERTIFICATE

STEAM WALLPAPER STRIPPER MODEL HTW5

Transcription:

Perfect Serv PSJR /PSSR Models Introduction............................................................................ Installation & Operating Instructions...................................................... Maintenance............................................................................ Appendix Cart Model Specifications & s.................................... 6 Dinex Warranty....................................................................... 50 NOTE: The document is to be used in conjunction with the Dinex s Perfect Serv Operation Manual For Service Information, call -888-67-469 Please provide following information: Model number Stamped-in code Part and number as shown in parts list. Manual PSRV Rev-04/05 DINEX INTERNATIONAL, INC. 68- HEBRON AVENUE, GLASTONBURY CT 060 WWW.DINEX.COM

Introduction: Congratulations! You have just purchased one of the finest pieces of equipment on the market today. Before installing or operating your new Dinex Products equipment you should read through this material. This manual should be retained for further reference as it contains installation instructions, service tips, part list and warranty information. Should you have any questions concerning the Equipment, please call the Dinex Hotline at -888-67-469 (Monday through Friday from 8 am to 5 pm, Eastern Standard Time).! IMPORTANT: For your safety, read and follow all cautions, information and warnings FREIGHT DAMAGE CLAIMS Your Dinex Products equipment was carefully inspected and packed before leaving our factory. The transportation company assumes full responsibility for safe delivery of this equipment. Dinex Products cannot assume responsibility for damage or loss incurred in transit. Visible damage or loss should be noted on freight bill and signed by person making delivery. A freight claim should be filed immediately with the transportation company. If damage is unnoticed or concealed until equipment is unpacked, notify the transportation company immediately and tell them you want to file a concealed damage claim. This must be done within fifteen (5) days after delivery was made. Be sure to retain all packing material and cartons. ELECTRICAL. Check that all packaging and protective materials are removed.. Prior to connection, check that the power supply is in accordance with the product Data Plate details.. All units are provided with a NEMA 65-0 plug. Dual supply units are fitted with a NEMA 5-5 plug on the 0 V AC line.! NOTE: Reference Appendix # for additional electrical information 4. Dual supply units are fitted with a rotary isolator, which must be turned to the on position after plugging the unit in. The isolator is located on the control panel. 5. Should there be any doubt concerning electrical specifications or hardware, seek advice from a competent electrician.! Installation: WARNING: This appliance MUST be grounded. If in doubt, seek the advice of a competent electrician. DO NOT attempt to change the type of plug fitted or connect to any power supply, which differs from Data Plate. DO NOT attempt to disconnect the unit while running.! WARNING: Installation of this equipment should be performed only by persons qualified or licensed to install electrical equipment. Adjustments and service work should be performed only by a qualified service technician. Service is available through Authorized Dinex Products & Service Distributors throughout the United States. For a complete listing of these consult your distributor listing or write Dinex Products for the name of the nearest distributor. This equipment in intended for commercial use only. Not for household use. Use of other than genuine Dinex Products replacements parts or service work performed by other than authorized Dinex Products service agents will void the warranty. Do not use any corrosive cleaners. Use only cleaners approved for stainless steel. ALL MODELS A. Regeneration cook/chill, cook/freeze B. Chillogen hold regeneration, cook/chill C. Hotline only. MODEL VARIATIONS Hotline Keep-Hot Compartments Keep-hot compartments are heated by fan assisted elements. The temperature is controlled by digital thermostat with temperature display.! Assembly Instructions: NOTE: All keep-hot compartments are factory pre-set to maintain a temperature of 85 F (85 C). Page

Refrigerated Compartments Complete With Ice-Cream Hold Facility Refrigerated compartments are cooled by a side mounted forced air system and controlled by digital thermostat with temperature display. Ice cream section operates automatically in conjunction with refrigerated section (no display).! NOTE: Refrigerated section is factory pre-set for 6 F ( C) to 4 F (5 C). Ice cream section is factory pre-set for F ( 5 C) to 8 F ( 8 C). Additional Feature: The ice cream section can be removed to utilize compartment as refrigerated compartment. ICE CREAM SECTION REMOVAL. Slide cassette out of the compartment and place on a level surface.. Lift ice cream coverflap and continue to slide the cover forward until it completely clears the cassette..the left and right side panels are removed by lifting them upward. Lift carefully until the locating angles clear the runners then move sideways and remove from cassette. 4. Reverse procedure to re-insert Plate Warmer Compartments Units with a plate warmer will accept 40 plates in the upper section and 4 full size deep pans in lower section at ambient temperature or separate refrigerated temperature depending on model.! NOTE: All plate warmer units are factory pre-set and regulate automatically to ensure plates are maintained at serving temperature (no temperature display). CLEANING Maintenance:. Before attempting to clean the unit, make sure that the unit is switched off and disconnected from the power supply and allowed to cool down completely.. Check that all plates and containers and any loose items are removed from the unit.. The interiors of all compartments are formed into a onepiece unit and the cassette can be easily removed. 4. The interior of all compartments can be cleaned using a water and stainless steel compatible disinfectant applied using a spray bottle. The interior should be completely dry prior to use.! WARNING: NEVER steam clean this equipment! NEVER spray water into the control compartment or onto the control panel. 5. The top, external and internal surfaces should be cleaned with a hot soapy damp cloth. 6. Scouring pads should not be used to clean glass, hot plates and sneeze guard glass. A glass cleaner should be used. 7. After cleaning, the cart should be carefully dried.! WARNING: DO NOT use chemicals such as bleach or undiluted cleaning agents. DO NOT use steel wool pads on ANY surface, this will cause rusting and/or scratching. DO NOT touch quartz sneeze guard lamps during cleaning. CASTERS All wheel bearings are sealed for life and will not require maintenance. PROBLEM. Loose axle bolt & nut. Abnormal play in swivel head in caster. Tire tread wear 4. Wheel operation obstruction DOOR HINGES/HANDLES/CATCHES SOLUTION. Tighten as required. Replace if worn. Replace wheel 4. Remove obstruction (string, etc) Incorrect adjustment of door hinges, handles and catch strike plates will cause an incorrect seal of the door gasket. This will cause poor performance, hot spots and gasket failure. It is recommended that monthly inspections of hinges, handles/catches be performed Page

. Loose hinge. Abnormal play in hinge. Loose door handle 4. Door handle for proper closing 5. Improper door closing at the catch strike plate 6. Excessive wear at door catch strike plate! NOTE: Hinges, handles and door catches found to be faulty due to abuse are not covered under warranty. Monthly inspections are the customer's responsibility and are NOT covered under warranty. DOOR GASKET REPLACEMENT Door gaskets should be inspected monthly for damage. Damaged gaskets must be replaced immediately following the instruction below.! NOTE:Inspections are NOT covered under warranty.. Open door fully.. Firmly hold the gasket at one corner and pull out (this will require some force). Continue to pull the gasket out until it is fully removed.. Starting at one corner place the tongue of the gasket into the slot and push hard to set gasket fully into place. Continue to press gasket fully into place all around the door. 4. Close door and check for correct fit and operation. 5. To check for positive gasket seal, place a piece of paper between the oven door and the cabinet body and close door. Some resistance should be experienced when pulling paper out. Check seal all the way round and adjust the door as necessary to obtain proper fit.! PROBLEM NOTE:Gaskets found to be damaged due to abuse are NOT covered under warranty. PLATE-WARMERS To remove plate-warmers:. Remove all plates. SOLUTION. Remove cover/tighten screws. Replace hinge. Tighten as required 4. Replace door handle 5. Adjust using M Allan key 6. Replace strike plate. Lift up and continue to pull out until the rack rollers clear the runner. 4. Reverse the procedure to re-insert. The only maintenance requirement on plate-warmers is light lubrication of the rollers.! NOTE: Only approved non-toxic lubricant specifically designed for use in the proximity of food must be used. FAN HOUSING COVER In the event that access is required behind the Fan Housing Cover:. Remove the internal cassette.. The cover can be removed by unscrewing thumbscrew. Slide the cover off of the locating pins then lift the cover to the right to clear the compartment.. Reverse the procedure to re-insert.! IMPORTANT: Extreme care must be exercised during this operation to ensure that the cover does not come into contact with the fan blades and result in possible damage. QUARTZ LAMP REPLACEMENT. Replacement quartz lamps must not exceed the wattage specified on the Maximum Wattage Label on the sneeze guard.. Switch off the unit, disconnect from the power supply and allow it to cool.. Carefully slide mesh guard to one side until it clears the bulb area. 4. Remove faulty lamp by pushing to one side then pull down. 5. Reverse of steps - 4 to install the new lamp.!! NOTE: It is recommended that bulb be installed using a non lubricated tissue. IMPORTANT: Lamps should not be touched with bare hands or any type of towel with contamination, as this will cause premature failure. If lamp is touched, wipe clean with a cloth and alcohol prior to use.. Pull the rack out until it stops. Page 4

REFRIGERATION SYSTEM The condenser and compressor are located behind a tamperproof, sealed, fixed control panel. This panel can be opened by removing () tamperproof screws from the upper flange and folding the panel down. Depending upon the model, it may be easier to access the refrigeration system by removing the louvered front panel. To remove the front panel perform the following:. Lift up the tray rail to the serving position.. Remove () bolts located on the underside of the bottom panel structure.. Remove the louvered front panel by pulling the bottom of the panel out first and letting it drop off of the upper support locating pins. 4. Perform required refrigeration maintenance and repairs. (i.e. cleaning of condenser) 5. Reinstall the front louvered panel in reverse of the removal process. ELECTRONIC COMPONENTS The electronic components and compressor are located behind a tamperproof, sealed, fixed control panel. Access to this compartment is provided by hinging the control panel down and by removing the body panel on the opposite side of the cart. Only an authorized service agent should access this compartment. Page 5

APPENDIX NO. Cart Model Specification & Part s Page 6

Perfect Serv Specification Chart PSJRG x 00 Watt 0 Volt Quartz Lamp 5.5 (cm) x 00 Watt 0 Volt Black Thermo Panel x 0 Volt 60Hz 5 Amp Plug 7.5 (95cm) x Phase 08 Volt 60Hz 0 Amp Plug 5000 Watt Thermalization Oven (x 000 Watt And x 000 Watt Elements) 9.5 (00cm) Bracket Attachment Prepared To Accept Anti Static Strip Full Depth Plexiglas Sneeze Screen 8 Pan Thermalization Oven c/w Cassette Standard 4 Castor Arrangement x 6cm Fixed x 6cm Swivel Braked MODEL DESCRIPTION DINENSIONS WEIGHT ELECTRICAL REFRIGERATION ADDITIONAL INFORMATION PSJRG 8 Pan Thermalization Compartment. 9.5 W (00cm) x 0 D (75cm) x 7.5 H (95cm) To Work Surface x 5.5 (cm) To Top Of Gantry 0 lbs. MAX : 5000 Watts (Via Inhibit Relay) MAXIMUM AMPS:.9 Per Phase N/A. For electrical wiring see drawing No. PSJRG.. When optional extra PSAVDL Data Logger System or PSAVOBP on board food probe with pass / fail are fitted, please refer to drawing No. PSAEOE for electrical wiring integration. A. Anti static bracket fitted as standard from August 04. Page 7

Perfect Serv Specification PSJRG Control Panel OVEN TEMPERATURE OVEN TIME BOOST READY Controller (Display) (460) Digital Countdown Timer (Display) (46) Ready Light () Amber Mini Neon (7) Way Switches (00E) REGEN OFF KEEP HOT Way Switch (00D) () Dotted Outline Shows Position Of Data Transfer Point (Window) When PSAVDL Option Is Fitted MAIN ISOLATOR 6 Pole Isolatator (980) Page 8

PSJRG Chart Chart 00 00 068A 964B 670 9DA 8 7DA 5A 00E D 0490 049 086 8 CHASSIS 60 Swivel Braked Caster 60 Fixed Caster Rubber Bumper (Per Unit) DOORS Lockable Handle c/w Catch Full Size Door Gasket TOP 0V x 00 Watt Black Thermo Panel GANTRY Quartz Lamp Holder 0V x 00 Watt Quartz Lamp Quartz Lamp Guard (Mesh) Gantry On / Off Switch ( Way) Full Depth Plexiglas Sneeze Screen CASSETTES S/S Wheels S/S Pins FAN GUARD Anti Tilt Pin M5X S/S Thumbscrew M 4 4 990 0A 09B 040B 460 46 00E 00D 7 980 95 945 060 46 8 675 05 0 99A 078 08 THERMALIZATION COMMENTS Fan Motors Fan Blade Rapid Heat Element 000 Watt Rapid Heat Element 000 Watt Digital Countdown Timer (Display) Way Switch Way Switch Amber Mini Neon 6 Pole Isolator 6 Amp Pole MCB 0 Amp Pole MCB Change Over Relay 4 Pole Relay Inhibit Relay 0V Transformer Delay Timer 5-5 Contacter Auto High Limit Stat 5 Amp Fuse 6 Amp Fuse 4 900 906 90 905 904 90 0 98 8 064 06 048 460 905 904 8 Optional Extras PSAVDL DATA LOGGING SYSTEM Data Logger PCB Board (Panel) Data Logger Push Button (Yellow) Data Logger Temp Display Screen Food Probe Food Probe Socket Data Transfer Point Window (Panel) Resistor 0V Transformer 0V Transformer 0V Relay Amp Fuse PSAVOBP ON BOARD PROBE WITH PASS / FAIL Red Mini Neon Food Probe Food Probe Socket 0V Transformer This section refers to electrical optional extras and is only vaild when ordered and fitted. PSSK PSSRGG This recommended spare parts kit is for PSJRG only and to order please quote PSSPK-PSJRG 964B 990 09B 040B 460 46 0 99A 675 7DA 9DA 078 08 Recommended Spare Kit Lockable Handle c/w Catch Fan Motor Rapid Heat Element 000 Watt Rapid Heat Element 000 Watt Digital Countdown Timer Display High Limit Stat Change Over Relay Delay Timer 0V x 00 Watt Quartz Lamp 0V v 00 Watt Black Thermo Panel 5 Amp Fuse 6 Amp Fuse Page 9

Perfect Serv Specification Chart PSJRC x 00 Watt 0 Volt Quartz Lamp 5.5 (cm) x 00 Watt 0 Volt Black Thermo Panel x 0 Volt 60Hz 5 Amp Plug 7.5 (95cm) x Phase 08 Volt 60Hz 0 Amp Plug 5000 Watt Thermalization Oven (x 000 Watt And x 000 Watt Elements) 9.5 (00cm) Bracket Attachment Prepared To Accept Anti Static Strip Full Depth Plexiglas Sneeze Screen 8 Pan Chillotherm Oven / Fridge c/w Cassette Standard 4 Castor Arrangement x 6cm Fixed x 6cm Swivel Braked MODEL DESCRIPTION DINENSIONS WEIGHT PSJRC 8 Pan Chillotherm Combined Oven / Fridge Compartment. 9.5 W (00cm) x 0 D (75cm) x 7.5 H (95cm) To Work Surface x 5.5 (cm) To Top Of Gantry 4 lbs. ELECTRICAL REFRIGERATION MAX : 5000 Watts (Via Inhibit Relay) MAXIMUM AMPS:.9 Per Phase REFRIGERANT GAS: R404A REFRIGERANT CHARGE: 500 GRAMS DESIGN PRESSURES HIGH = 7-9 BAR LOW =.5 - BAR ADDITIONAL INFORMATION. For electrical wiring see drawing No. PSJRC.. When optional extra PSAVDL Data Logger System or PSAVOBP on board food probe with pass / fail or PSAV7DT 7 day programmable timer are fitted please refer to drawing No. PSAEOE for electrical wiring integration. A. Anti static bracket fitted as standard from August 04. Page 0

Perfect Serv Specification PSJRC Control Panel (This Control Panel Represents The Manual Operated Version) OVEN TEMPERATURE Controller (Display) (460) Digital Countdown Timer (Display) (46) Ready Light () CHILOGEN ON S OVEN TIME BOOST READY Amber Mini Neon (7) Way Switch (00D) REGEN OFF KEEP HOT Way Switches (00E) () Dotted Outline Shows Position Of Data Transfer Point (Window) When PSAVDL Option Is Fitted MAIN ISOLATOR FRIDGE TEMPERATURE Controller (Display) (460) Operates In Chillotherm Mode Showing Cold Temperature 6 Pole Isolatator (980) Page

Perfect Serv Specification PSJRC Control Panel (This Control Panel Represents The Automated Version With 7 Day Timer) PSAV7DT 7 Day Programmable Timer (044) 7 Day Timer OVEN TEMPERATURE OVEN TIME BOOST READY Controller (Display) (460) Digital Countdown Timer (Display) (46) Ready Light () Amber Mini Neon (7) Way Switch (00D) KEEP HOT Way Switches (00E) () Dotted Outline Shows Position Of Data Transfer Point (Window) When PSAVDL Option Is Fitted MAIN ISOLATOR FRIDGE TEMPERATURE Controller (Display) (460) Operates In Chillotherm Mode Showing Cold Temperature 6 Pole Isolatator (980) Page

Chart PSJRC Chart 00 00 068A 964B 670 9DA 8 7DA 5A 00E D 0490 049 086 8 900 906 90 905 904 90 0 98 8 064 06 048 460 905 904 8 044 CHASSIS 60 Swivel Braked Caster 60 Fixed Caster Rubber Bumper (Per Unit) DOORS Lockable Handle c/w Catch Full Size Door Gasket TOP 0V x 00 Watt Black Thermo Panel GANTRY Quartz Lamp Holder 0V x 00 Watt Quartz Lamp Quartz Lamp Guard (Mesh) Gantry On / Off Switch ( Way) Full Depth Plexiglas Sneeze Screen CASSETTES S/S Wheels S/S Pins FAN GUARD Anti Tilt Pin M5X S/S Thumbscrew Optional Extras PSAVDL DATA LOGGING SYSTEM Data Logger PCB Board (Panel) Data Logger Push Button (Yellow) Data Logger Temp Display Screen Food Probe Food Probe Socket Data Transfer Point Window (Panel) Resistor 0V Transformer 0V Transformer 0V Relay Amp Fuse PSAVOBP ON BOARD PROBE WITH PASS / FAIL Red Mini Neon Food Probe Food Probe Socket 0V Transformer PSAV7DT 7 DAY PROGRAMMABLE TIMER Le-Grand 7 Day Timer This section refers to electrical optional extras and is only vaild when ordered and fitted. M 4 4 Page 990 0A 09B 040B 460 46 00E 00D 7 980 95 945 060 46 8 675 05 0 99A 078 08 605D 75A 008D 040 0054 460 THERMALIZATION COMMENTS Fan Motors Fan Blade Rapid Heat Element 000 Watt Rapid Heat Element 000 Watt Digital Countdown Timer (Display) Way Switch Way Switch Amber Mini Neon 6 Pole Isolator 6 Amp Pole MCB 0 Amp Pole MCB Change Over Relay 4 Pole Relay Inhibit Relay 0V Transformer Delay Timer 5-5 Contacter Auto High Limit Stat 5 Amp Fuse 6 Amp Fuse CHILLOTHERM FUNCTION TO OVEN Dinex U.L. Compressor () Lu-Ve Condenser Coil High Speed Condenser Fan High Pressure Cut Out Switch /4 Filter Drier 0.5 Capillary Tube 5 M

PSSK PSJRC This recommended spare parts kit is for PSJRG only and to order please quote PSSPK-PSJRC 964B 990 09B 040B 460 46 0 99A 675 7DA 9DA 078 08 605D 0054 Recommended Spare Kit Lockable Handle c/w Catch Fan Motor Rapid Heat Element 000 Watt Rapid Heat Element 000 Watt Digital Countdown Timer Display High Limit Stat Change Over Relay Delay Timer 0V x 00 Watt Quartz Lamp 0V v 00 Watt Black Thermo Panel 5 Amp Fuse 6 Amp Fuse Dinex U.L Compressor () 0.5 Capillary Tube M Page 4

x 0 Volt 60Hz 5 Amp Plug Perfect Serv Specification Chart 5.5 (cm) 7.5 (95cm) PSSRGG x 00 Watt 0 Volt Quartz Lamps x 00 Watt 0 Volt Black Thermo Panels x Phase 08 Volt 60Hz 0 Amp Plug 000 Watt Thermalization Oven. (x 000 Watt Elements) 57.5 (45cm) Bracket Attachment Prepared To Accept Anti Static Strip Full Depth Plexiglas Sneeze Screen 8 Pan Ambient Compartment c/w Cassette 8 Pan Thermalization Oven c/w Cassette Standard 4 Caster Arrangement x 6cm Fixed x 6cm Swivel Braked Alternative 6 Caster Arrangement x 6cm Swivel x 6cm Fixed x 6cm Swivel Braked MODEL DESCRIPTION DINENSIONS WEIGHT ELECTRICAL REFRIGERATION ADDITIONAL INFORMATION PSSRGG Two 8 Pan Thermalization Oven 57.5 W (45cm) x 0 D (75cm) x 7.5 H (95cm) To Work Surface x 5.5 (cm) To Top Of Gantry 6 lbs. MAX : 6000 Watts (Via Inhibit Relay) MAXIMUM AMPS: 6.6 Per Phase N/A. For electrical wiring see drawing No. PSSRGG.. When optional extra PSAVDL Data Logger System or PSAVOBP on board food probe with pass / fail are fitted, please refer to drawing No. PSAEOE for electrical wiring integration. A. All Perfect Serv senior gantry switches operate quartz lamp and black thermo panel together from May 04. B. Anti static bracket fitted as standard from August 04. Page 5

Perfect Serv Specification PSSRGG Control Panel Controller (Display) (460) Digital Countdown Timer (Display) (46) OVEN TEMPERATURE OVEN TEMPERATURE Controller (Display) (460) Digital Countdown Timer (Display) (46) Ready Light () Ready Light () READY READY Amber Mini Neon (7) OVEN TIME BOOST REGEN OFF REGEN OFF OVEN TIME BOOST Amber Mini Neon (7) Way Switch (00D) Way Switches (00E) () KEEP HOT REGEN OFF REGEN OFF KEEP HOT Way Switch (00D) Way Switches (00E) () Dotted Outline Shows Position Of Data Transfer Point (Window) When PSAVDL Option Is Fitted MAIN ISOLATOR 6 Pole Isolatator (980) Page 6

PSSRGG Chart Chart 00 00 00 068A 964B 670 9DA 8 7DA 5A 00E D 0490 049 086 8 CHASSIS 60 Swivel Braked Caster 60 Swivel Caster (Alternative 6 Caster Only) 60 Fixed Caster Rubber Bumper (Per Unit) DOORS Lockable Handle c/w Catch Full Size Door Gasket TOP 0V x 00 Watt Black Thermo Panel GANTRY Quartz Lamp Holder 0V x 00 Watt Quartz Lamp Quartz Lamp Guard (Mesh) Gantry On / Off Switch ( Way) Full Depth Plexiglas Sneeze Screen CASSETTES S/S Wheels S/S Pins FAN GUARD Anti Tilt Pin M5X S/S Thumbscrew 5M 8 8 4 990 0A 09B 040B 460 46 00E 00D 7 980 95 945 060 46 8 675 05 0 99A 078 08 THERMALIZATION COMMENTS Fan Motors Fan Blade Rapid Heat Element 000 Watt Rapid Heat Element 000 Watt Digital Countdown Timer (Display) Way Switch Way Switch Amber Mini Neon 6 Pole Isolator 6 Amp Pole MCB 0 Amp Pole MCB Change Over Relay 4 Pole Relay Inhibit Relay 0V Transformer Delay Timer 5-5 Contacter Auto High Limit Stat 5 Amp Fuse 6 Amp Fuse 6 6 4 4 8 4 4 4 6 900 906 90 905 904 90 0 98 8 064 06 048 460 905 904 8 Optional Extras PSAVDL DATA LOGGING SYSTEM Data Logger PCB Board (Panel) Data Logger Push Button (Yellow) Data Logger Temp Display Screen Food Probe Food Probe Socket Data Transfer Point Window (Panel) Resistor 0V Transformer 0V Transformer 0V Relay Amp Fuse PSAVOBP ON BOARD PROBE WITH PASS / FAIL Red Mini Neon Food Probe Food Probe Socket 0V Transformer This section refers to electrical optional extras and is only vaild when ordered and fitted. PSSK PSSRGG This recommended spare parts kit is for PSSRGG only and to order please quote PSSPK-PSSRGG 964B 990 09B 040B 460 46 0 99A 675 7DA 9DA 078 08 Recommended Spare Kit Lockable Handle c/w Catch Fan Motor Rapid Heat Element 000 Watt Rapid Heat Element 000 Watt Digital Countdown Timer Display High Limit Stat Change Over Relay Delay Timer 0V x 00 Watt Quartz Lamp 0V v 00 Watt Black Thermo Panel 5 Amp Fuse 6 Amp Fuse Page 7

x 0 Volt 60Hz 5 Amp Plug Perfect Serv Specification Chart 5.5 (cm) 7.5 (95cm) PSSRGA 57.5 (45cm) x 00 Watt 0 Volt Quartz Lamps x 00 Watt 0 Volt Black Thermo Panels x Phase 08 Volt 60Hz 0 Amp Plug 5000 Watt Thermalization Oven. (x 000 Watt & x 000 Watt Elements) Bracket Attachment Prepared To Accept Anti Static Strip Full Depth Plexiglas Sneeze Screen 8 Pan Ambient Compartment c/w Cassette 8 Pan Thermalization Oven c/w Cassette Standard 4 Caster Arrangement x 6cm Fixed x 6cm Swivel Braked Alternative 6 Caster Arrangement x 6cm Swivel x 6cm Fixed x 6cm Swivel Braked MODEL DESCRIPTION DINENSIONS WEIGHT ELECTRICAL REFRIGERATION ADDITIONAL INFORMATION PSSRGA 8 Pan Thermalization Oven and 8 Pan Ambient Compartment 57.5 W (45cm) x 0 D (75cm) x 7.5 H (95cm) To Work Surface x 5.5 (cm) To Top Of Gantry 6 lbs. MAX : 5000 Watts (Via Inhibit Relay) MAXIMUM AMPS:.9 Per Phase N/A. For electrical wiring see drawing No. PSSRGA.. When optional extra PSAVDL Data Logger System or PSAVOBP on board food probe with pass / fail are fitted, please refer to drawing No. PSAEOE for electrical wiring integration. A. All Perfect Serv senior gantry switches operate quartz lamp and black thermo panel together from May 04. B. Anti static bracket fitted as standard from August 04. Page 8

Perfect Serv Specification PSSRGA Control Panel OVEN TEMPERATURE Controller (Display) (460) Digital Countdown Timer (Display) (46) Ready Light () READY REGEN OFF OVEN TIME BOOST Amber Mini Neon (7) Way Switch (00D) REGEN OFF KEEP HOT Way Switches (00E) () Dotted Outline Shows Position Of Data Transfer Point (Window) When PSAVDL Option Is Fitted MAIN ISOLATOR 6 Pole Isolatator (980) Page 9

PSSRGA Chart Chart 00 00 00 068A 964B 670 9DA 8 7DA 5A 00E D 0490 049 086 8 CHASSIS 60 Swivel Braked Caster 60 Swivel Caster (Alternative 6 Caster Only) 60 Fixed Caster Rubber Bumper (Per Unit) DOORS Lockable Handle c/w Catch Full Size Door Gasket TOP 0V x 00 Watt Black Thermo Panel GANTRY Quartz Lamp Holder 0V x 00 Watt Quartz Lamp Quartz Lamp Guard (Mesh) Gantry On / Off Switch ( Way) Full Depth Plexiglas Sneeze Screen CASSETTES S/S Wheels S/S Pins FAN GUARD Anti Tilt Pin M5X S/S Thumbscrew 5M 8 8 4 990 0A 09B 040B 460 46 00E 00D 7 980 95 945 060 46 8 675 05 0 99A 078 08 THERMALIZATION COMMENTS Fan Motors Fan Blade Rapid Heat Element 000 Watt Rapid Heat Element 000 Watt Digital Countdown Timer (Display) Way Switch Way Switch Amber Mini Neon 6 Pole Isolator 6 Amp Pole MCB 0 Amp Pole MCB Change Over Relay 4 Pole Relay Inhibit Relay 0V Transformer Delay Timer 5-5 Contacter Auto High Limit Stat 5 Amp Fuse 6 Amp Fuse 4 900 906 90 905 904 90 0 98 8 064 06 048 460 905 904 8 Optional Extras PSAVDL DATA LOGGING SYSTEM Data Logger PCB Board (Panel) Data Logger Push Button (Yellow) Data Logger Temp Display Screen Food Probe Food Probe Socket Data Transfer Point Window (Panel) Resistor 0V Transformer 0V Transformer 0V Relay Amp Fuse PSAVOBP ON BOARD PROBE WITH PASS / FAIL Red Mini Neon Food Probe Food Probe Socket 0V Transformer This section refers to electrical optional extras and is only vaild when ordered and fitted. PSSK PSSRGA This recommended spare parts kit is for PSSRGA only and to order please quote PSSPK-PSSRGA 964B 990 09B 040B 460 46 0 99A 675 7DA 9DA 078 08 Recommended Spare Kit Lockable Handle c/w Catch Fan Motor Rapid Heat Element 000 Watt Rapid Heat Element 000 Watt Digital Countdown Timer Display High Limit Stat Change Over Relay Delay Timer 0V x 00 Watt Quartz Lamp 0V v 00 Watt Black Thermo Panel 5 Amp Fuse 6 Amp Fuse Page 0

x 0 Volt 60Hz 5 Amp Plug 500 Watt Compressor To Refrigerated Compartment Perfect Serv Specification Chart 5.5 (cm) 7.5 (95cm) PSSRGR 57.5 (45cm) x 00 Watt 0 Volt Quartz Lamps x 00 Watt 0 Volt Black Thermo Panels x Phase 08 Volt 60Hz 0 Amp Plug 5000 Watt Thermalization Oven. (x 000 Watt & x 000 Watt Elements) Bracket Attachment Prepared To Accept Anti Static Strip Full Depth Plexiglas Sneeze Screen 8 Pan Refrigerated Compartment c/w Cassette (Shown With Ice Cream Base Hold Facility Reducing Capacity To 6 Pan) 8 Pan Thermalization Oven c/w Cassette Standard 4 Caster Arrangement x 6cm Fixed x 6cm Swivel Braked Alternative 6 Caster Arrangement x 6cm Swivel x 6cm Fixed x 6cm Swivel Braked MODEL DESCRIPTION DINENSIONS WEIGHT PSSRGR 8 Pan Thermalization Oven and 8 Pan Refrigerated Compartment. 57.5 W (45cm) x 0 D (75cm) x 7.5 H (95cm) To Work Surface x 5.5 (cm) To Top Of Gantry 8 lbs. ELECTRICAL REFRIGERATION MAX : 5500 Watts (Via Inhibit Relay) MAXIMUM AMPS: 5. Per Phase REFRIGERANT GAS: R404A REFRIGERANT CHARGE: 400 GRAMS DESIGN PRESSURES HIGH = 7-9 BAR LOW =.5 - BAR ADDITIONAL INFORMATION. For electrical wiring see drawing No. PSSRGA.. When optional extra PSAVDL Data Logger System or PSAVOBP on board food probe with pass / fail are fitted, please refer to drawing No. PSAEOE for electrical wiring integration. A. All Perfect Serv senior gantry switches operate quartz lamp and black thermo panel together from May 04. B. Anti static bracket fitted as standard from August 04. Page

Perfect Serv Specification PSSRGR Control Panel Fridge Digital Display Control (0) FRIDGE TEMPERATURE OVEN TEMPERATURE Controller (Display) (460) Digital Countdown Timer (Display) (46) Ready Light () READY REGEN OFF OVEN TIME BOOST Amber Mini Neon (7) Way Switch (00D) REGEN OFF KEEP HOT Way Switches (00E) () Dotted Outline Shows Position Of Data Transfer Point (Window) When PSAVDL Option Is Fitted MAIN ISOLATOR 6 Pole Isolatator (980) Page

PSSRGR Chart Chart 00 00 00 068A 964B 670 9DA 8 7DA 5A 00E D 0490 049 086 8 900 906 90 905 904 90 0 98 8 064 06 048 460 905 904 8 CHASSIS 60 Swivel Braked Caster 60 Swivel Caster (Alternative 6 Caster Only) 60 Fixed Caster Rubber Bumper (Per Unit) DOORS Lockable Handle c/w Catch Full Size Door Gasket TOP 0V x 00 Watt Black Thermo Panel GANTRY Quartz Lamp Holder 0V x 00 Watt Quartz Lamp Quartz Lamp Guard (Mesh) Gantry On / Off Switch ( Way) Full Depth Plexiglas Sneeze Screen CASSETTES S/S Wheels S/S Pins FAN GUARD Anti Tilt Pin M5X S/S Thumbscrew Optional Extras PSAVDL DATA LOGGING SYSTEM Data Logger PCB Board (Panel) Data Logger Push Button (Yellow) Data Logger Temp Display Screen Food Probe Food Probe Socket Data Transfer Point Window (Panel) Resistor 0V Transformer 0V Transformer 0V Relay Amp Fuse PSAVOBP ON BOARD PROBE WITH PASS/FAIL Red Mini Neon Food Probe Food Probe Socket 0V Transformer This section refers to electrical optional extras and is only vaild when ordered and fitted. 5M 8 8 4 Page 990 0A 09B 040B 460 46 00E 00D 7 980 95 945 060 46 8 675 05 0 99A 078 08 990 0A 608D 75A 008D 040 60 0 964B 990 09B 040B 460 46 0 99A 675 608D 60 7DA 9DA THERMALIZATION COMMENTS Fan Motors Fan Blade Rapid Heat Element 000 Watt Rapid Heat Element 000 Watt Digital Countdown Timer (Display) Way Switch Way Switch Amber Mini Neon 6 Pole Isolator 6 Amp Pole MCB 0 Amp Pole MCB Change Over Relay 4 Pole Relay Inhibit Relay 0V Transformer Delay Timer 5-5 Contacter Auto High Limit Stat 5 Amp Fuse 6 Amp Fuse REFRIGERATED COMMENT Fan Motor Fan Blade Dinex U.L. Compressor (6) Lu-Ve Condenser Coil High Speed Condenser Fan High Pressure Cut Out Switch /4 Filter Drier 0.6 Capillary Tube Fridge Digital Display Control Recommended Spare Kit Lockable Handle c/w Catch Fan Motor Rapid Heat Element 000 Watt Rapid Heat Element 000 Watt Digital Countdown Timer Display High Limit Stat Change Over Relay Delay Timer Dinex U.L Compressor (6) 0.6 Capillary Tube 0V x 00 Watt Quartz Lamp 0V v 00 Watt Black Thermo Panel 4 M PSSK PSSRGR This recommended spare parts kit is for PSSRGR only and to order please quote PSSPK-PSSRGR M

x 500 Watt Plate Warming Element x 0 Volt 60Hz 5 Amp Plug 500 Watt Compressor To Refrigerated Compartment Perfect Serv Specification Chart 5.5 (cm) 7.5 (95cm) PSSRGPR 57.5 (45cm) x 00 Watt 0 Volt Quartz Lamps x 00 Watt 0 Volt Black Thermo Panels x Phase 08 Volt 60Hz 0 Amp Plug 5000 Watt Thermalization Oven. (x 000 Watt & x 000 Watt Elements) Bracket Attachment Prepared To Accept Anti Static Strip Full Depth Plexiglas Sneeze Screen 40 x 0 Plate Warming Section (Racked Vertically On Pull Out Arrangement) 4 Pan Refrigerated Compartment c/w Cassette.This Unit Also Has Ice Cream Base Hold Facility (Not Shown) Reducing Capacity To Pan When Used 8 Pan Thermalization Oven c/w Cassette Standard 4 Caster Arrangement x 6cm Fixed x 6cm Swivel Braked Alternative 6 Caster Arrangement x 6cm Swivel x 6cm Fixed x 6cm Swivel Braked MODEL DESCRIPTION DINENSIONS WEIGHT PSSRGPR 8 Pan Thermalization Oven and 40 Plate Warmer And 4 Pan Refrigerated Compartment (Seperate). 57.5 W (45cm) x 0 D (75cm) x 7.5 H (95cm) To Work Surface x 5.5 (cm) To Top Of Gantry 96 lbs. ELECTRICAL REFRIGERATION MAX : 6000 Watts (Via Inhibit Relay) MAXIMUM AMPS: 6.6 Per Phase REFRIGERANT GAS: R404A REFRIGERANT CHARGE: 400 GRAMS DESIGN PRESSURES HIGH = 7-9 BAR LOW =.5 - BAR ADDITIONAL INFORMATION. For electrical wiring see drawing No. PSSRGPR.. When optional extra PSAVDL Data Logger System or PSAVOBP on board food probe with pass / fail are fitted, please refer to drawing No. PSAEOE for electrical wiring integration. A. All Perfect Serv senior gantry switches operate quartz lamp and black thermo panel together from May 04. B. Anti static bracket fitted as standard from August 04. Page 4

Perfect Serv Specification PSSRGPR Control Panel 0-0 Degree Thermostat (0) Function Selected Light () () PLATE WARMER REGEN OFF OVEN TEMPERATURE OVEN TIME BOOST READY Controller (Display) (460) Digital Countdown Timer (Display) (46) Ready Light () Amber Mini Neon (7) Way Switch (00D) REGEN OFF KEEP HOT Way Switches (00E) () Fridge Digital Display Control (0) FRIDGE TEMPERATURE Dotted Outline Shows Position Of Data Transfer Point (Window) When PSAVDL Option Is Fitted MAIN ISOLATOR 6 Pole Isolatator (980) Page 5

PSSRGPR Chart Chart 00 00 00 068A 964B 670 67 9DA 8 7DA 5A 00E D 0490 049 086 8 900 906 90 905 904 90 0 98 8 064 06 048 460 905 904 8 CHASSIS 60 Swivel Braked Caster 60 Swivel Caster (Alternative 6 Caster Only) 60 Fixed Caster Rubber Bumper (Per Unit) DOORS Lockable Handle c/w Catch Full Size Door Gasket / Size Door Gasket To P/W & Fridge TOP 0V x 00 Watt Black Thermo Panel GANTRY Quartz Lamp Holder 0V x 00 Watt Quartz Lamp Quartz Lamp Guard (Mesh) Gantry On / Off Switch ( Way) Full Depth Plexiglas Sneeze Screen CASSETTES S/S Wheels S/S Pins FAN GUARD Anti Tilt Pin M5X S/S Thumbscrew Optional Extras PSAVDL DATA LOGGING SYSTEM Data Logger PCB Board (Panel) Data Logger Push Button (Yellow) Data Logger Temp Display Screen Food Probe Food Probe Socket Data Transfer Point Window (Panel) Resistor 0V Transformer 0V Transformer 0V Relay Amp Fuse PSAVOBP ON BOARD PROBE WITH PASS/FAIL Red Mini Neon Food Probe Food Probe Socket 0V Transformer This section refers to electrical optional extras and is only vaild when ordered and fitted. 5M 8 8 4 Page 6 990 0A 09B 040B 460 46 00E 00D 7 980 95 945 060 46 8 675 05 0 99A 078 08 990 0A 608D 75A 008D 040 60 0 THERMALIZATION COMMENTS Fan Motors Fan Blade Rapid Heat Element 000 Watt Rapid Heat Element 000 Watt Digital Countdown Timer (Display) Way Switch Way Switch Amber Mini Neon 6 Pole Isolator 6 Amp Pole MCB 0 Amp Pole MCB Change Over Relay 4 Pole Relay Inhibit Relay 0V Transformer Delay Timer 5-5 Contacter Auto High Limit Stat 5 Amp Fuse 6 Amp Fuse REFRIGERATED COMMENT Fan Motor Fan Blade Dinex U.L. Compressor (6) Lu-Ve Condenser Coil High Speed Condenser Fan High Pressure Cut Out Switch /4 Filter Drier 0.6 Capillary Tube Fridge Digital Display Control 4 M

964B 990 09B 040B 460 46 0 99A 675 608D 60 7DA 9DA 700 0 Recommended Spare Kit PSSK PSSRGPR This recommended spare parts kit is for PSSRGPR only and to order please quote PSSPK-PSSRGPR Lockable Handle c/w Catch Fan Motor Rapid Heat Element 000 Watt Rapid Heat Element 000 Watt Digital Countdown Timer Display High Limit Stat Change Over Relay Delay Timer Dinex U.L Compressor (6) 0.6 Capillary Tube 0V x 00 Watt Quartz Lamp 0V v 00 Watt Black Thermo Panel 500 Watt Circular Element 0-0 Degree Thermostat M Page 7

Perfect Serv Specification Chart PSSRGPA x 00 Watt 0 Volt Quartz Lamps x 0 Volt 60Hz 5 Amp Plug x 500 Watt Plate Warming Element 5.5 (cm) 7.5 (95cm) x 00 Watt 0 Volt Black Thermo Panels x Phase 08 Volt 60Hz 0 Amp Plug 5000 Watt Thermalization Oven. (x 000 Watt & x 000 Watt Elements) 57.5 (45cm) Bracket Attachment Prepared To Accept Anti Static Strip Full Depth Plexiglas Sneeze Screen 40 x0 Plate Warming Section (Racked Vertically On Pull OutArrangement) Thermal Wedge Divides Compartment 4 Pan Ambient Area c/w Cassette. 8 Pan Thermalization Oven c/w Cassette Standard 4 Caster Arrangement x 6cm Fixed x 6cm Swivel Braked Alternative 6 Caster Arrangement x 6cm Swivel x 6cm Fixed x 6cm Swivel Braked MODEL DESCRIPTION DINENSIONS WEIGHT ELECTRICAL REFRIGERATION ADDITIONAL INFORMATION PSSRGPA 8 Pan Thermalization Oven And 40 Plate Warmer And 4 Pan Ambient Compartment (Combined). 57.5 W (45cm) x 0 D (75cm) x 7.5 H (95cm) To Work Surface x 5.5 (cm) To Top Of Gantry 6 lbs. MAX : 5500 Watts (Via Inhibit Relay) MAXIMUM AMPS: 5. Per Phase N/A. For electrical wiring see drawing No. PSSRGPA.. When optional extra PSAVDL Data Logger System or PSAVOBP on board food probe with pass / fail are fitted, please refer to drawing No. PSAEOE for electrical wiring integration. A. All Perfect Serv senior gantry switches operate quartz lamp and black thermo panel together from May 04. B. Anti static bracket fitted as standard from August 04. Page 8

Perfect Serv Specification PSSRGPA Control Panel 0-0 Degree Thermostat (0) Function Selected Light () () PLATE WARMER REGEN OFF OVEN TEMPERATURE OVEN TIME BOOST READY Controller (Display) (460) Digital Countdown Timer (Display) (46) Ready Light () Amber Mini Neon (7) Way Switch (00D) REGEN OFF KEEP HOT Way Switches (00E) () Dotted Outline Shows Position Of Data Transfer Point (Window) When PSAVDL Option Is Fitted MAIN ISOLATOR 6 Pole Isolatator (980) Page 9

PSSRGPA Chart Chart 00 00 00 068A 964B 670 9DA 8 7DA 5A 00E D 0490 049 086 8 900 906 90 905 904 90 0 98 8 064 06 048 460 905 904 8 CHASSIS 60 Swivel Braked Caster 60 Swivel Caster (Alternative 6 Caster Only) 60 Fixed Caster Rubber Bumper (Per Unit) DOORS Lockable Handle c/w Catch Full Size Door Gasket TOP 0V x 00 Watt Black Thermo Panel GANTRY Quartz Lamp Holder 0V x 00 Watt Quartz Lamp Quartz Lamp Guard (Mesh) Gantry On / Off Switch ( Way) Full Depth Plexiglas Sneeze Screen CASSETTES S/S Wheels S/S Pins FAN GUARD Anti Tilt Pin M5X S/S Thumbscrew Optional Extras PSAVDL DATA LOGGING SYSTEM Data Logger PCB Board (Panel) Data Logger Push Button (Yellow) Data Logger Temp Display Screen Food Probe Food Probe Socket Data Transfer Point Window (Panel) Resistor 0V Transformer 0V Transformer 0V Relay Amp Fuse PSAVOBP ON BOARD PROBE WITH PASS/FAIL Red Mini Neon Food Probe Food Probe Socket 0V Transformer This section refers to electrical optional extras and is only vaild when ordered and fitted. 5M 8 8 4 Page 0 990 0A 09B 040B 460 46 00E 00D 7 980 95 945 060 46 8 675 05 0 99A 078 08 990 0A 700 0 05 964B 990 09B 040B 460 46 0 99A 675 7DA 9DA 700 0 078 08 THERMALIZATION COMMENTS Fan Motors Fan Blade Rapid Heat Element 000 Watt Rapid Heat Element 000 Watt Digital Countdown Timer (Display) Way Switch Way Switch Amber Mini Neon 6 Pole Isolator 6 Amp Pole MCB 0 Amp Pole MCB Change Over Relay 4 Pole Relay Inhibit Relay 0V Transformer Delay Timer 5-5 Contacter Auto High Limit Stat 5 Amp Fuse 6 Amp Fuse PLATE WARMER COMMENT Fan Motor Fan Blade 500 Watt Circular Element 0-0 Degree Thermostat 0-0 Knob For Thermostat Recommended Spare Kit PSSK PSSRGPA This recommended spare parts kit is for PSSRGPA only and to order please quote PSSPK-PSSRGPA Lockable Handle c/w Catch Fan Motor Rapid Heat Element 000 Watt Rapid Heat Element 000 Watt Digital Countdown Timer Display High Limit Stat Change Over Relay Delay Timer 0V x 00 Watt Quartz Lamp 0V v 00 Watt Black Thermo Panel 500 Watt Circular Element 0-0 Degree Thermostat 5 Amp Fuse 6 Amp Fuse 4 4

x 0 Volt 60Hz 5 Amp Plug Bracket Attachment Prepared To Accept Anti Static Strip Perfect Serv Specification Chart 5.5 (cm) 7.5 (95cm) PSSRCA 57.5 (45cm) x 00 Watt 0 Volt Quartz Lamps x 00 Watt 0 Volt Black Thermo Panels x Phase 08 Volt 60Hz 0 Amp Plug 5000 Watt Chillotherm Combined Oven/ Fridge. (x 000 Watt And x 000 Watt Elements) 000 Watt Compressor For Chillotherm Function Full Depth Plexiglas Sneeze Screen 8 Pan Ambient Compartment c/w Cassette 8 Pan Chillotherm CombinedOven/ Fridge c/w Cassette Standard 4 Caster Arrangement x 6cm Fixed x 6cm Swivel Braked Alternative 6 Caster Arrangement x 6cm Swivel x 6cm Fixed x 6cm Swivel Braked MODEL DESCRIPTION DINENSIONS WEIGHT PSSRCA 8 Pan Chillotherm Combined Oven / Fridge And 8 Pan Ambient Compartment. 57.5 W (45cm) x 0 D (75cm) x 7.5 H (95cm) To Work Surface x 5.5 (cm) To Top Of Gantry 96 lbs. ELECTRICAL REFRIGERATION MAX : 6000 Watts (Via Inhibit Relay) MAXIMUM AMPS: 6.6 Per Phase REFRIGERANT GAS: R404A REFRIGERANT CHARGE: 500 GRAMS DESIGN PRESSURES HIGH = 7-9 BAR LOW =.5 - BAR ADDITIONAL INFORMATION. For electrical wiring see drawing No. PSSRCA.. When optional extra PSAVDL Data Logger System or PSAVOBP on board food probe with pass / fail or PSAV7DT 7 day programmable timer are fitted, please refer to drawing No. PSAEOE for electrical wiring integration. A. All Perfect Serv senior gantry switches operate quartz lamp and black thermo panel together from May 04. B. Anti static bracket fitted as standard from August 04. Page

Perfect Serv Specification PSSRCA Control Panel (This Control Panel Represents The Manual Operated Version) OVEN TEMPERATURE CHILOGEN ON REGEN OFF S OVEN TIME BOOST KEEP HOT READY Controller (Display) (460) Digital Countdown Timer (Display) (46) Ready Light () Amber Mini Neon (7) Way Switch (00D) Way Switches (00E) () Dotted Outline Shows Position Of Data Transfer Point (Window) When PSAVDL Option Is Fitted MAIN ISOLATOR FRIDGE TEMPERATURE Controller (Display) (460) Operates In Chillotherm Mode Showing Cold Temperature 6 Pole Isolatator (980) Page

Perfect Serv Specification PSSRCA Control Panel (This Control Panel Represents The Automated Version With 7 Day Timer) PSAV7DT 7 Day Programmable Timer (044) 7 Day Timer OVEN TEMPERATURE OVEN TIME BOOST READY Controller (Display) (460) Digital Countdown Timer (Display) (46) Ready Light Green Mini Neon () Amber Mini Neon (7) Way Switch (00D) KEEP HOT Way Switch (00E) () Dotted Outline Shows Position Of Data Transfer Point (Window) When PSAVDL Option Is Fitted MAIN ISOLATOR FRIDGE TEMPERATURE Controller (Display) (460) Operates In Chillotherm Mode Showing Cold Temperature 6 Pole Isolatator (980) Page

PSSRCA Chart Chart 00 00 00 068A 964B 670 9DA 8 7DA 5A 00E D 0490 049 086 8 900 906 90 905 904 90 0 98 8 064 06 048 460 905 904 8 CHASSIS 60 Swivel Braked Caster 60 Swivel Caster (Alternative 6 Caster Only) 60 Fixed Caster Rubber Bumper (Per Unit) DOORS Lockable Handle c/w Catch Full Size Door Gasket TOP 0V x 00 Watt Black Thermo Panel GANTRY Quartz Lamp Holder 0V x 00 Watt Quartz Lamp Quartz Lamp Guard (Mesh) Gantry On / Off Switch ( Way) Full Depth Plexiglas Sneeze Screen CASSETTES S/S Wheels S/S Pins FAN GUARD Anti Tilt Pin M5X S/S Thumbscrew Optional Extras PSAVDL DATA LOGGING SYSTEM Data Logger PCB Board (Panel) Data Logger Push Button (Yellow) Data Logger Temp Display Screen Food Probe Food Probe Socket Data Transfer Point Window (Panel) Resistor 0V Transformer 0V Transformer 0V Relay Amp Fuse PSAVOBP ON BOARD PROBE WITH PASS/FAIL Red Mini Neon Food Probe Food Probe Socket 0V Transformer PSAV7DT 7 DAY PROGRAMMABLE TIMER Le-Grand 7 Day Timer 5M 044 This section refers to electrical optional extras and is only vaild when ordered and fitted. 8 8 4 Page 4 990 0A 09B 040B 460 46 00E 00D 7 980 95 945 060 46 8 675 05 0 99A 078 08 605D 75A 008D 040 0054 460 964B 990 09B 040B 460 46 0 99A 675 7DA 9DA 078 08 605D 0054 CHILLOTHERM COMMENT Fan Motors Fan Blade Rapid Heat Element 000 Watt Rapid Heat Element 000 Watt Digital Countdown Timer (Display) Way Switch Way Switch Amber Mini Neon 6 Pole Isolator 6 Amp Pole MCB 0 Amp Pole MCB Change Over Relay 4 Pole Relay Inhibit Relay 0V Transformer Delay Timer 5-5 Contacter Auto High Limit Stat 5 Amp Fuse 6 Amp Fuse CHILLOTHERM FUNCTION TO OVEN Dinex U.L. Compressor () Lu-Ve Condenser Coil High Speed Condenser Fan High Pressure Cut Out Switch /4 Filter Drier 0.5 Capillary Tube Recommended Spare Kit Lockable Handle c/w Catch Fan Motor Rapid Heat Element 000 Watt Rapid Heat Element 000 Watt Digital Countdown Timer Display High Limit Stat Change Over Relay Delay Timer 0V x 00 Watt Quartz Lamp 0V x 00 Watt Black Thermo Panel 5 Amp Fuse 6 Amp Fuse Dinex U.L Compressor () 0.5 Capillary Tube 5 M PSSK PSSRCA This recommended spare parts kit is for PSSRCA only and to order please quote PSSPK-PSSRCA M

x 500 Watt Plate Warming Element x 0 Volt 60Hz 5 Amp Plug 000 Watt Compressor To Refrigerated Compartment And Chillogen Function Within Oven Perfect Serv Specification Chart 5.5 (cm) 7.5 (95cm) PSSRCPR 57.5 (45cm) x 00 Watt 0 Volt Quartz Lamps x 00 Watt 0 Volt Black Thermo Panels x Phase 08 Volt 60Hz 0 Amp Plug 5000 Watt Thermalization Oven (x 000 Watt & x 000 Watt Elements) Bracket Attachment Prepared To Accept Anti Static Strip Full Depth Plexiglas Sneeze Screen 40 x 0 Plate Warming Section (Racked Vertically On Pull Out Arrangement) 4 Pan Refrigerated Compartment c/w Cassette.This Unit Also Has Ice Cream Base Hold Facility (Not Shown) Reducing Capacity To Pan When Used 8 Pan Chillogen Oven / Fridge c/w Cassette Standard 4 Caster Arrangement x 6cm Fixed x 6cm Swivel Braked Alternative 6 Caster Arrangement x 6cm Swivel x 6cm Fixed x 6cm Swivel Braked MODEL DESCRIPTION DINENSIONS WEIGHT PSSRCPR 8 Pan Chillogen Combined Oven / Fridge And 40 Plate Warmer And 4 Pan Refrigerated Compartment (Separate). 57.5 W (45cm) x 0 D (75cm) x 7.5 H (95cm) To Work Surface x 5.5 (cm) To Top Of Gantry 96 lbs. ELECTRICAL REFRIGERATION MAX : 6500 Watts (Via Inhibit Relay) MAXIMUM AMPS: 8.0 Per Phase REFRIGERANT GAS: R404A REFRIGERANT CHARGE: 600 GRAMS DESIGN PRESSURES HIGH = 7-9 BAR LOW =.5 - BAR ADDITIONAL INFORMATION. For electrical wiring see drawing No. PSSRCPR.. When optional extra PSAVDL Data Logger System or PSAVOBP on board food probe with pass / fail or PSAV7DT 7 day programmable timer are fitted, please refer to drawing No. PSAEOE for electrical wiring integration. A. All Perfect Serv senior gantry switches operate quartz lamp and black thermo panel together from May 04. B. Anti static bracket fitted as standard from August 04. Page 5

Perfect Serv Specification PSSRCPR Control Panel (This Control Panel Represents The Manual Operated Version) 0-0 Degree Thermostat (0) Function Selected Light () () PLATE WARMER OVEN TEMPERATURE CHILOGEN ON S OVEN TIME BOOST READY Controller (Display) (460) Digital Countdown Timer (Display) (46) Ready Light () Amber Mini Neon (7) Way Switch (00D) REGEN OFF KEEP HOT Way Switches (00E) () Fridge Digital Display Control (0) FRIDGE TEMPERATURE Dotted Outline Shows Position Of Data Transfer Point (Window) When PSAVDL Option Is Fitted MAIN ISOLATOR FRIDGE TEMPERATURE Controller (Display) (460) Operates In Chillotherm Mode Showing Cold Temperature 6 Pole Isolatator (980) Page 6

Perfect Serv Specification PSSRCPR Control Panel (This Control Panel Represents The Automated Version With 7 Day Timer) 0-0 Degree Thermostat (0) PSAV7DT 7 Day Programmable Timer (044) Function Selected Light () () PLATE WARMER 7 Day Timer OVEN TEMPERATURE Controller (Display) (460) Digital Countdown Timer (Display) (46) Ready Light Green Mini Neon () OVEN TIME BOOST READY Amber Mini Neon (7) Way Switch (00D) Fridge Digital Display Control (0) FRIDGE TEMPERATURE KEEP HOT Way Switch (00E) () Dotted Outline Shows Position Of Data Transfer Point (Window) When PSAVDL Option Is Fitted MAIN ISOLATOR FRIDGE TEMPERATURE Controller (Display) (460) Operates In Chillotherm Mode Showing Cold Temperature 6 Pole Isolatator (980) Page 7

PSSRCPR Chart Chart 00 00 00 068A 964B 670 9DA 8 7DA 5A 00E D 0490 049 086 8 900 906 90 905 904 90 0 98 8 064 06 048 460 905 904 8 CHASSIS 60 Swivel Braked Caster 60 Swivel Caster (Alternative 6 Caster Only) 60 Fixed Caster Rubber Bumper (Per Unit) DOORS Lockable Handle c/w Catch Full Size Door Gasket TOP 0V x 00 Watt Black Thermo Panel GANTRY Quartz Lamp Holder 0V x 00 Watt Quartz Lamp Quartz Lamp Guard (Mesh) Gantry On / Off Switch ( Way) Full Depth Plexiglas Sneeze Screen CASSETTES S/S Wheels S/S Pins FAN GUARD Anti Tilt Pin M5X S/S Thumbscrew Optional Extras PSAVDL DATA LOGGING SYSTEM Data Logger PCB Board (Panel) Data Logger Push Button (Yellow) Data Logger Temp Display Screen Food Probe Food Probe Socket Data Transfer Point Window (Panel) Resistor 0V Transformer 0V Transformer 0V Relay Amp Fuse PSAVOBP ON BOARD PROBE WITH PASS/FAIL Red Mini Neon Food Probe Food Probe Socket 0V Transformer PSAV7DT 7 DAY PROGRAMMABLE TIMER Le-Grand 7 Day Timer 5M 044 This section refers to electrical optional extras and is only vaild when ordered and fitted. 8 8 4 Page 8 990 0A 09B 040B 460 46 00E 00D 7 980 95 945 060 46 8 675 05 0 99A 078 08 990 0A 605D 75A 008D 040 60 0054 470 0 460 990 0A 700 0 05 CHILLOTHERM COMMENT Fan Motors Fan Blade Rapid Heat Element 000 Watt Rapid Heat Element 000 Watt Digital Countdown Timer (Display) Way Switch Way Switch Amber Mini Neon 6 Pole Isolator 6 Amp Pole MCB 0 Amp Pole MCB Change Over Relay 4 Pole Relay Inhibit Relay 0V Transformer Delay Timer 5-5 Contacter Auto High Limit Stat 5 Amp Fuse 6 Amp Fuse REFRIGERATED COMMENT & CHILLOTHERM FUNCTION TO OVEN Fan Motor Fan Blade Dinex U.L. Compressor () Lu-Ve Condenser Coil High Speed Condenser Fan High Pressure Cut Out Switch /4 Filter Drier 0.6 Capillary Tube 0.5 Capillary Tube Solenoid Valves Fridge Digital Display Control PLATE WARMER COMMENT Fan Motor Fan Blade 500 Watt Circular Element 0-0 Degree Thermostat 0-0 Knob For Thermostat 5 4 M M

PSSK PSSRCPR This recommended spare parts kit is for PSSRCPR only and to order please quote PSSPK-PSSRCPR 964B 990 09B 040B 460 46 0 99A 675 605D 60 0054 470 078 08 700 0 Recommended Spare Kit Lockable Handle c/w Catch Fan Motor Rapid Heat Element 000 Watt Rapid Heat Element 000 Watt Digital Countdown Timer Display High Limit Stat Change Over Relay Delay Timer Dinex U.L Compressor () 0.6 Capillary Tube 0.5 Capillary Tube Solenoid Valve 5 Amp Fuse 6 Amp Fuse 500 Watt Circular Element 0-0 Thermostat M M Page 9

x 500 Watt Plate Warming Element x 0 Volt 60Hz 5 Amp Plug Bracket Attachment Prepared To Accept Anti Static Strip Perfect Serv Specification Chart 5.5 (cm) 7.5 (95cm) PSSRCPA 57.5 (45cm) x 00 Watt 0 Volt Quartz Lamps x 00 Watt 0 Volt Black Thermo Panels x Phase 08 Volt 60Hz 0 Amp Plug 5000 Watt Thermalization Oven (x 000 Watt & x 000 Watt Elements) 000 Watt Compressor For Chillogen Function Full Depth Plexiglas Sneeze Screen 40 x 0 Plate Warming Section (Racked Vertically On Pull Out Arrangement) Thermal Wedge Divides Compartment 4 Pan Ambient Area c/w Cassette 8 Pan Chillogen Oven / Fridge c/w Cassette Standard 4 Caster Arrangement x 6cm Fixed x 6cm Swivel Braked Alternative 6 Caster Arrangement x 6cm Swivel x 6cm Fixed x 6cm Swivel Braked MODEL DESCRIPTION DINENSIONS WEIGHT PSSRCPA 8 Pan Chillotherm Oven / Fridge and 40 Plate Warmer And 4 Pan Ambient Compartment (Combined). 57.5 W (45cm) x 0 D (75cm) x 7.5 H (95cm) To Work Surface x 5.5 (cm) To Top Of Gantry 96 lbs. ELECTRICAL REFRIGERATION MAX : 6500 Watts (Via Inhibit Relay) MAXIMUM AMPS: 8.0 Per Phase REFRIGERANT GAS: R404A REFRIGERANT CHARGE: 500 GRAMS DESIGN PRESSURES HIGH = 7-9 BAR LOW =.5 - BAR ADDITIONAL INFORMATION. For electrical wiring see drawing No. PSSRCPA.. When optional extra PSAVDL Data Logger System or PSAVOBP on board food probe with pass / fail or PSAV7DT 7 day programmable timer are fitted, please refer to drawing No. PSAEOE for electrical wiring integration. A. All Perfect Serv senior gantry switches operate quartz lamp and black thermo panel together from May 04. B. Anti static bracket fitted as standard from August 04. Page 40