39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Similar documents
FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

CLIMACIAT AIR COMPACT

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

Vertical self-contained air conditioner

42AM. Air heaters PRODUCT SELECTION DATA

CLIMACIAT. air HanDLIng UnIT: CLIMaCIaT. Air handling unit

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

Precision air handling cabinets Ciatronic MICRO/EXPAIR

N M AirControl AHU. Control manual

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

UNITES TERMINALES ET MINI CTA FIDJI

DAIKIN Air Handling Unit Modular

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

NA N FLOWAY Control. Control manual

We simplify construction

CLIMASTER ZCF AIR HANDLING UNITS

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

TopMaster Air Handling unit. Technical data

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

air handling units AT THE LEADING EDGE OF AIR FLOW

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Product catalogue Air handling units. Easy and flexible solutions for any ventilation requirements

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

KOMFORT EC DB Suspended heat recovery air handling units

TopVent Design Handbook

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

The ultimate in air handling units: directly and indirectly fired

Do you want a versatile solution

The ultimate in air handling units: directly and indirectly fired

High temperature air-to-water heat pumps

Centrifugal air heaters hot water or electrical supply

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

The integral solution for. Air Handling Units. Technology & Evolution

EN CLIMACIAT. Control manual

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

SIMPLICITY FULL MODULARITY?

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements

SIMPLICITY OR FULL MODULARITY?

We simplify construction

Compact. Efficient. TROX.

TopMaster Air Handling Unit

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Product Brochure Modular Air Handling Units CAIRplus. Multiflow liquid-coupled energy recovery system

The plug & play fresh Air Solution

Air Handling Units. Geniox. Quick guide

GLOBAL RX. Ventilation unit with rotary heat exchanger

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

We simplify construction

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

HT V2 HT Split

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

VORT NRG RANGE COMMERCIAL VENTILATION NEW

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

AIR HANDLING UNITS ver B

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

AL-KO CONTROL TECHNOLOGY THE SIMPLE ROUTE TO CONTROL

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

TOPAZ ADIABATIC COOLER

New HEE control. n Room thermostat for THREE-PHASE or SINGLE-PHASE installation

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Series VENTS VUT R WH ЕС

Energy-efficient heat source provides comfort in large rooms

NA G µair CONNECT 2

Halton Rex for Vario R6O - Variable air volume chilled beam

NA B AIR COMPACT. Instruction manual

Flexible & Innovative. Cooling Solutions

Technical documentation. ComfoAir XL The latest generation of ventilation units with heat recovery

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

kw. Flexair. General description. Main components. CLIMATIC controller. Air cooled rooftop packaged unit

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

SEQUENCE OF OPERATIONS

Roof top SPACE RPC 450Z R407C M011

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

Water and ground source heat pumps 61WG kw. Heating

Roof top SPACE RPC 315Z R407C MA00

Transcription:

PRODUCT SELECTION DATA Plug & play unit (built-in control) Class A+ across entire range Classic/Vertical/ceiling-mounted dualflow units High-efficiency heat recovery unit High performance plug fan High-efficiency dual-flow 39H CARRIER participates in the ECP programme for LCP/HP Check ongoing validity of certificated www.eurovent-certification.com www.certiflash.com Translation of the original document 20024, 08.2016

Use The 39H dual-flow is a PLUG & PLAY ventilation unit equipped with a highly efficient heat recovery unit with plug fans and high performance EC motors, designed to meet all the requirements of recent ecodesign regulations. Unit supplied ready to use, prewired, preprogrammed in the factory and supplied with a remote control. It draws clean, fresh air indoors using, on average, 80% less energy than that needed for air conditioning (cooling and heating). These units are designed for use in the following applications: Administrative buildings, Offices Shopping Centres Education facilities, Libraries, Nursing homes, Community centres Healthcare facilities Cafés, Hotels, Restaurants Collective housing é All facilities where ventilation is required. Specifications Mechanical strength Airtightness Filter bypass leak Thermal transmission Thermal bridge 39HE model: 9 sizes, air flow from 300 to 18,000 m 3 /h. Floor-mounted horizontal unit with horizontal air flows and air connections on the sides. 39HA model: 5 sizes, air flow from 350 to 8500m³/h. 39HC model: 5 sizes, air flow from 300 to 6600 m 3 /h. Ground installation, horizontal position, horizontal air flow, air circuits on the sides. 39HV model: 3 sizes, air flow from 300 to 2600 m 3 /h. Ground installation, vertical position, vertical air flow, air circuits on the top. 39HH model: 3 sizes, air flow from 300 to 1900 m 3 /h. Ceiling-mounted horizontal unit with vertical air flows and air connections on the sides. High energy-efficiency heat recovery unit Depending on its layout, the 39H offers two different high-efficiency heat recovery systems: Class D2 L2 F9 T3 TB2 "CONTRA FLOW" plate heat exchanger equipped with a bypass (C, V, H models) Rotary heat exchanger (39HA and 39HE models) Year-round optimal heat recovery unit Range Classic 39HC & 39HE MODELS Nominal flow rate (m 3 /h) Max. power* (kw) Max current* (A) Voltage (V) 010 1000 1,43 6,2 1-Ph 230 020 2000 2,50 3,6 030 3000 3,82 5,5 040 4000 4,23 6,1 050 5000 4,23 6,1 060 6000 6,03 8,7 3-Ph 400 075 7500 6,03 8,7 100 10000 12,06 17,4 150 15000 15,45 22,3 39HA MODELS Nominal flow rate (m 3 /h) Max. power* (kw) Max current* (A) Voltage (V) 010 1000 1,2 5,4 1-Ph 230 020 2000 2,5 2,9 030 3000 4,2 6,1 050 5000 6,1 8,8 3-Ph 400 075 7500 7,1 10,3 Vertical 39HV MODELS Nominal flow rate (m 3 /h) Max. power* (kw) Max current* (A) Voltage (V) 007 1000 1,43 6,2 1-Ph 230 015 1500 2,50 3,6 020 2000 2,50 3,6 3-Ph 400 Ceiling-mounted 39HH MODELS Nominal flow rate (m 3 /h) Max. power* (kw) Max current* (A) Voltage (V) 007 700 1,43 6,2 1-Ph 230 012 1200 1,43 6,2 016 1600 2,50 3,6 3-Ph 400 * These values are provided for guidance only and are based on a standard dual-flow unit without electric heater option. 3

Description Casing n Double-skin panels made from sheet steel, galvanised on both sides, thickness 8/10 mm. n RAL 7035 grey precoated external panels. n Class M0/A1. n Mineral wool, thickness 50 mm. Filtration n M5 HEE, F7 HEE, F9 HEE filters. n Filter cells kept compressed by a special system to ensure a leaktight seal. n HC, HV, HH models: fouling value monitored by analogue sensor and displayed by controller. n HA model: pressure switch control on each air flow. Pressure switch status displayed by controller. Ventilation n Plug fan driven by an electronically commutated motor (EC motor, built-in variable speed control). Heat recovery units n "Contra Flow" plate heat exchanger equipped with a motorised bypass (HC, HH and HV models). é Efficiency greater than 80% across the range of air flows. n Rotary heat exchanger equipped with rotation variable speed control (39HE model). é Efficiency greater than 80% at nominal flow rate. n Constant speed rotary heat exchanger (HA model) é Efficiency greater than 80% at nominal flow rate. Hydraulic coil n Copper pipes, aluminium fins. n Coil can be integrated or additional (cased). n With the accessory fitted, 2 or 3-way control valve and 0-10V actuator controlled by 39H Control for setpoint accuracy. n Stainless steel condensate drain pan (cooling coil or mixed coil only). n Electrics box for power, control and internal regulation of the unit, comprising as standard: - Power supply (3-Ph/400 V/Earth or 1-Ph/230 V/Earth). - Main disconnect switch. - Protected transformer. - Protection and control of all electrical components by a circuit breaker and contact switch. - Peripheral options and power terminal block. - Factory-programmed PLC control. - Hand-held cabled micro-terminal. - Fault summary contact. - 3 temperature sensors. - 4 pressure sensors (2 pressure sensors and 2 pressure switches on the 39HA model). Accessories Damper formed of airfoil blades, powered by a servomotor On/off with return spring. Flexible sleeve. Adjustable feet. CO 2 air quality sensor. Roof. Canopy. Mixing section. Indoor environment switch. ModBus RTU, LON, KN, ModBus communication TCP, Bacnet IP, web interface. Electrics box Electric heaters n High-limit safety thermostat with automatic and manual reset. n Control by 2-stage on/off operation fully controlled by 39H Control. MODELS & SIZES Power (kw) Current (A) Voltage (V) C 010 & E 010 V 007 4,5 20 1-Ph 230 H 070 & H 012 V 015 (additional casing) H 016 (additional casing) 7,20 11 V 015 8,1 12 C 020 & E 020 10,8 16 C 030 & E 030 12,6 19 C 040 & E 040 16,8 25 3-Ph 400 E 050 19,8 29 C 060 & E 060 22,8 34 E 075 31,2 46 E 100 N/A N/A E 150 N/A N/A 4

Control 39H Control The 39H features, as standard, an electrics box equipped with a factory-programmed PLC and a hand-held micro-terminal. 39H Control function Included Options* Fan time schedule Built-in timer: management in series 4 events per year, per week and per day By fresh air temperature control Frost protection By exhaust air flow pressure on heat recovery unit delta control (pressure sensor) Monitoring of sensor status Safety Monitoring operation values (thresholds) Operating control of EC fan motor assemblies Filter fouling control (via analogue sensor or pressure switch, depending on the model) Fault summary Fire monitoring (potential free (dry) contact available (normally closed)) Alarms Management of alarms and log (100) Control of return air or supply air temperature Control mode Hot air and/or cold air production Free cooling Night cooling function Regulated temperature control based on outdoor temperature Control of room temperature with a room terminal Gradual action on the 2- or 3-way control valve on the hydraulic coil Gradual action on the electric heater TRIAC On/Off action on the various stages of the electric heater Shut down the rotary heat exchanger (HE and HA models) Open the bypass on the Contra Flow plate heat exchanger (HC, HV and HH models) Shut down the rotary heat exchanger (HE and HA models) Open the bypass on the Contra Flow plate heat exchanger (HC, HV and HH models) Morning heating function Control degree of opening of mixing bypass (HE model) Eco-recycling function Control degree of opening of mixing bypass (HE model) Efficiency optimisation Configuration of the air flow rate Constant flow rate operation Modulation of flow rates operation Communicating mode Miscellaneous Variation of the rotation speed of the rotary recovery unit (HE model) 2 air flow rate setpoints per air flow Display of the air flow rate Keeps the air flow rate constant regardless of how fouled the filters are Signal 0-10V CO 2 sensor Single zone Presence contact Contact External contact Multi zone Air supply duct constant pressure operation ModBus RS485 protocol LON protocol Management by CMS KN protocol ModBus TCP/BACNET IP protocol Web interface Languages supported (French/English/German/Dutch/Spanish/Italian) Integrated temperature sensors (*3: fresh air supply and extraction, exhaust air extraction) Integrated pressure checks (*4: fresh air and exhaust air filter fouling level, fresh air and exhaust air fan) Damper control Information provided to the user via the hand-held micro terminal Contact for controlling the pumps for the hydraulic coils (with operating control)** Contact for controlling an external outdoor heat production system (boiler, etc.)** Contact for controlling a humidifier** Electric heater load shedding input** Option*: Requires the component to be selected as an option: damper, coil, CO 2 sensor, etc. ** Except 39HA model 5

Air flow dimensions and orientation Classic 39HC, 39HE & 39HA SIZES Height (C) (mm) Width (B) (mm) 39HC, 39HE & 39HA Length (A) (mm) Weight (kg)* HC HA HE HC HA HE 010 958 810 1580** 1266 1266** 200 180 201 020 1158 1010 1150 + 800** 1310 510 + 800** 350 250 309 030 1359 1210 1264 + 800 1600 800 + 800 465 330 432 040 1659 1510 1264 + 800-800 + 800 580-558 050 1659 1510-1600 800 + 800-445 604 060 1959 1810 1407 + 800-800 + 800 765-702 075 1959 1810-1600 800 + 800-580 751 100 2090 1920 - - 1100 + 1100 - - 955 150 2340 2192 - - 1100 + 1200 - - 1250 * Without internal option. ** Circular coupling; protrudes 47 mm on either side. AIR FLOW ORIENTATION 39HE & 39HA models ROTS 2.1 WHITE ARROW = FRESH AIR ROTS 2.2 39HC models BLACK ARROW = ETRACTED AIR PLAS01 PLAS02 6

Vertical 39HV MODELS Dimensions Weight (kg)* Height Length Width 007 1385 1313 730 202 015 1758 1593 832 330 020 1901 1735 832 389 Ø 16 mm condensate drain pipe. * Without internal option Size 007 1313 1270 730 702 492.5 584.5 193 250 250 250 250 46 272 193 584.5 492.5 124 Size 015 1550 1593 805 832 WHITE ARROW = FRESH AIR BLACK ARROW = EHAUST AIR 572 730 248 46 248 730 572 Size 020 1735 1692 832 805 124 47 100 349 47 100 47 620 824 248 46 248 824 620 385 1901 1854 1754 253 295 253 253 1758 1711 1611 295 253 231 70 70 70 1385 1338 1238 239 231 100 124 WHITE ARROW = FRESH AIR BLACK ARROW = EHAUST AIR 7

Ceiling-mounted 39HH MODELS Dimensions Weight (kg) Height Length Width 007 585 1453 896 161 012 585 1592 1174 206 016 585 1850 1456 279 Ø 16 mm condensate drain pipe. Size 007 13.5 47 1359 47 Size 012 WHITE ARROW = FRESH AIR BLACK ARROW = ETRACTED AIR 13.5 1202 924 Size 016 13.5 WHITE ARROW = FRESH AIR BLACK ARROW = ETRACTED AIR 1484 1456 1506 1174 1224 896 946 1453 280 799 280 47 1498 47 1592 280 938 280 47 1762 47 1856 280 601 A 601 B 280 MODELS Air flow dimensions (MM) A B C D 253 007 306 306 Ø160 Ø315 C D 16 71 C 012 398 398 Ø250 Ø 016 499.5 499.5 Ø250 Ø400 4745 8

Additional casing (MUST ONLY BE POSITIONED IN A HORIZONTAL AIR FLOW) 39H MODELS Additional casing sizes (mm) Weight (kg) E 010 & C 010 V 007 H 007 E 020 & C 020 V 015 & V 020 P 012 & P 016 E 030 & C 030 E 040 & E 050 C 040 & C 050 E 060 & E 075 C 060 & C 075 Size1 542 x 496 x 810 Size 2 642 x 496 x 1010 Size 3 759 x 400 x 1210 Size 4 909 x 400 x 1510 Size 5 1059 x 400 x 1810 49 kg 62 kg 68 kg 88 kg 112 kg Size 1 Size 2 Size 3 Size 4 Size 5 9

Classic 39HE model performance F5 exhaust filter, F7 intake filter, duct pressure: 200 Pa, heat recovery unit conditions: 0 C/90% - 20 C/50% Operating pressure = f(flow) Pressure Heat recovery unit efficiency = f (flow rate) Efficiency SFPv ahu = f (flow rate) SFPv SFPv = 0.6 W/(m 3 /h) RT reference output 10

39HA model performance F5 exhaust filter, F7 intake filter, duct pressure: 200 Pa, heat recovery unit conditions: 0 C/90% - 20 C/50% Operating pressure = f(flow) Pressure Pa Heat recovery unit efficiency = f (flow rate) Efficiency SFPv ahu = f (flow rate) SFPv SFPv = 0.6 W/(m 3 /h) RT reference output 11

Classic 39HC model performance F5 exhaust filter, F7 intake filter, duct pressure: 200 Pa, heat recovery unit conditions: 0 C/90% - 20 C/50% Operating pressure = f(flow) Pressure Heat recovery unit efficiency = f (flow rate) Efficiency SFPv SFPv ahu = f (flow rate) SFPv=0.6 W/(m3/h) RT reference output 12

Vertical 39HV model performance F5 exhaust filter, F7 intake filter, duct pressure: 200 Pa, heat recovery unit conditions: 0 C/90% - 20 C/50% Pressure Operating pressure = f(flow) Heat recovery unit efficiency = f (flow rate) Efficiency SFPv ahu = f (flow rate) SFPv SFPv = 0.6 W/(m 3 /h) RT reference output 13

Ceiling-mounted 39HH model performance F5 exhaust filter, F7 intake filter, duct pressure: 200 Pa, heat recovery unit conditions: 0 C/90% - 20 C/50% Operating pressure = f(flow) Pressure Heat recovery unit efficiency = f (flow rate) Efficiency SFPv ahu = f (flow rate) SFPv SFPv = 0.6 W/(m 3 /h) RT reference output 14

Quality and Environment Management Systems Approval Order No.: 10024, 08.2016 - Supersedes order No.: New The manufacturer reserves the right to change any product specifications without notice. Manufactured for Carrier in France. Printed in the European Union.