Level Measurement Continuous level measurement Ultrasonic transmitters

Similar documents
Level Measurement Continuous level measurement - Ultrasonic transmitters

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

Continuous level measurement Ultrasonic transmitters

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

Continuous level measurement - Radar transmitters

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Ultrasonic switch. Pointek ULS200. Quick Start Manual 03/2013. Milltronics

Flow Measurement SITRANS F C

Temperature Measurement Transmitters for field mounting

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 3100 Series Ultrasonic Level Transmitters

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH. Instruction Manual August 2002

Laser Level Measurement Products. Introducing the New LLT100

Flow Measurement SITRANS F C

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

SITRANS T temperature transmitters A broad product family for every application. sitrans

MT3809G Series. Data Sheet. Metal Tube Variable Area Flowmeters. Overview. Product Description. Variable Area

Explore the future of flow measurement. SITRANS FC430 - the market s most compact Coriolis solution. Process Instrumentation. Answers for industry.

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

Flow Measurement SITRANS F C

Non-Contacting Point Level Detection and Pump Control Sensor. Setting a New World Standard

Inductive Conductivity

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Process Protection. 6/2 Product overview. 6/3 Acoustic and Motion sensing. Acoustic sensors for pump monitoring 6/5 SITRANS DA400

Process Protection. 6/2 Overview. 6/3 Acoustic and motion sensing. Acoustic sensors for pump monitoring 6/5 SITRANS DA400 acoustic diagnostic unit

Rosemount 2120 Vibrating Fork Liquid Level Switch

Advanced Level Seminar 2015

Condumax CLS16 and CLS16D

Flow Measurement SITRANS F C. Transmitter FCT030

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 2090F Hygienic Pressure Transmitter

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

Ultrasonic Point Level Switches

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Magnetostrictive sensor For bypass level indicators Model BLM

Explore the future of flow measurement. SITRANS FC430 - the most compact NTEP approved Coriolis flow meter. Process Instrumentation

Temperature measurement with SITRANS T siemens.com/processinstrumentation

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

LOW PRESSURE Intrinsically Safe Transducer AST44LP

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

Ultrasonic Switches. Features & Benefits

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Level gauges Series LS Level indicator, switch and transmitter for liquids

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

ULTIMA X5000. MSAX5000.com

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet. Specification

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

Rosemount 3051CFC Compact Flowmeter

Intelligent sensing for every temperature and condition

Rosemount 3051CFP Integral Orifice Flowmeter

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Model 144H. Product Data Sheet , Rev DB February Content

Toroidal Conductivity Transmitters Series APT4000 Specifications

Enraf Servo Gauge 854 XTG

M5800 Pressure Transducer with Rotatable Display

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Druck DPI 705/DPI 705 IS Series

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

M5200 Industrial Pressure Transducer

M5800 Pressure Transducer with Rotatable Display

Dräger Polytron 8000 Stationary gas detector (EC)

Quick Start Manual July pointek CLS100

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

MEAS CAL ALARM WASH CONF APT4000 TC

Rosemount 2120 Vibrating Fork Liquid Level Switch

Azbil introduction 2015

industrial electronics electronic level measurement system

SENSOR PRESENTATION MISSION CRITICAL APPLICATIONS IN HARSH ENVIRONMENT

User s Manual YTA610 and YTA710 NEPSI Certification

U5300 Industrial Pressure Transducer

Rosemount 4500 Hygienic Pressure Transmitter. Start

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Rosemount 4500 Hygienic Pressure Transmitter

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Operating Instructions Edition 02/2007

MT3809G Series. Metal Tube Variable Area Flowmeters. Overview. Product Description. Variable Area

Rosemount 3490 Series

Ar-Mite TM Low Flow Armored Flowmeter

API Marine. Sensors Presentation. Mission critical applications in harsh environment. - API - Acoustic Precise Instruments -

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Sanitary Pressure Transmitter

Ultrasonic Level Measurement nivopuls FDU 10 S

ClampOn DSP Corrosion- Erosion Monitor

Dräger Polytron 7000 Fixed gas detector

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

Rosemount 8800D Series Vortex Flowmeter

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Transcription:

Overview Configuration is a short-range integrated ultrasonic level transmitter. This intrinsically safe, 2 wire, 4 to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials in open or closed vessels to 5 m (16.4 ft). Benefits Easy to install, program, and maintain Accurate and reliable Sanitary models available Patented Sonic Intelligence echo processing Integral temperature compensation Fill Application The transducer is available in PVDF copolymer, making the device suitable for use in a wide variety of applications. is easy to install and maintain, and can be quickly removed for cleaning as required by the food, beverage, and pharmaceutical industries. The reliability of the level data is based on the Sonic Intelligence echo processing algorithms. A filter discriminates between the true echo and false echoes from acoustic or electrical noises and agitator blades in motion. The ultrasonic pulse propagation time to the material and back is temperature-compensated and converted into distance for display, analog output. Key Applications: chemical storage vessels, filter beds, mud pits, liquid storage vessels, food applications Pipe Rungs Seams 12º Beam Angle mounting Siemens FI 01 News 2016 4/1

Technical specifications Mode of operation Measuring principle Ultrasonic level measurement Input Measuring range 0.25... 5 m (0.8... 16.4 ft) Frequency 54 khz Output ma 4... 20 ma Span Proportional/ inversely proportional Max. load 600 in the loop at 24 V DC Power supply Supply voltage 12... 30 V DC, 0.1 A surge Max. power consumption 0.75 W (25mAat24VDC) Certificates and approvals CSA: IS/ Class I, II, III, Div. 1, Groups: A, B, C, D, E, F, G T4 FM: IS/ Class I, II, III, Div. 1, Groups: A, B, C, D, E, F, G T4 ATEX: II 1G Ex ia IIC T4 Ga IECEx Ex ia IIC T4 Ga NEPSI Ex ia II C T4 Ga Accuracy Error in measurement 0.25 % of measuring range (in air) Resolution 3 mm (0.125 inch) Temperature Built in compensation Echo processing Sonic Intelligence Rated operation conditions Beam angle 12 Ambient temperature Standard -40... +60 C (-40... +140 F) Metallic mounting -20... +60 C (-4... +140 F) Max. static operating pressure Normal atmospheric pressure Design Weight 1.3 kg (2.9 lb) Material Electronics enclosure PBT Transducer PVDF copolymer Degree of protection IP68 / NEMA 6 / TYPE 6 Process connection 2" NPT [(Taper), ANSI/ASME B1.20.1] R 2" [(BSPT), EN 10226] or G 2" [(BSPP), EN ISO 228-1] Flange adapter 3" Universal, (fits DN 65, PN 10 and 3" ASME) 4" sanitary Cable inlet 1 inlet for M20, optional 1/2" NPT Selection and Ordering data Article No. Short-range integrated ultrasonic level transmitter, 7ML5202-0 7 7 0 intrinsically safe, 2 wire, 4 to 20 ma loop powered ideal for liquids, slurries, and bulk materials in open or closed vessels to 5 m (16.4 ft). Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Transducer/Process connection PVDF copolymer, 2" NPT E [(Taper), ANSI/ASME B1.20.1] PVDF copolymer, R 2" [(BSPT), EN 10226] F PVDF copolymer, G 2" [(BSPP), EN ISO 228-1] G PVDF copolymer, 4" Sanitary mounting J Cable inlet M20 x 1.5 (no cable gland included) M20 x 1.5 [General Purpose cable gland -20... +60 C (-4... +140 F) included] 1/2" NPT stainless steel entry (no cable gland included) Selection and Ordering data Further designs Please add "-Z" to Article No. and specify Order code(s). Stainless steel tag [13 x 45 mm (0.5 x 1.75 inch)]: Measuring-point number/ identification (max. 20 characters) specify in plain text A B C Order code Y15 Test certificate: Manufacturer's test certificate C11 M to DIN 55350, Part 18 and to ISO 9000 Operating Instructions Article No. English A5E37100674 German A5E37100685 Note: Operating instructions should be ordered as a separate line on the order All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/ documentation This device is shipped with the Siemens Level and Weighing manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch), 7ML1930-1AC one text line Universal box bracket mounting kit 7ML1830-1BK Sanitary 4" mounting clamp 7ML1830-1BR 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BT adapter for 2" NPT 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BU adapter for 2" BSPT 2" NPT locknut, plastic 7ML1830-1DT 2" BSPT locknut, plastic 7ML1830-1DQ Cable Gland, General Purpose A5E34457564-20... +60 C (-4... +140 F) We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. 4/2 Siemens FI 01 News 2016

Options, Flange Adapter The can be fitted with the optional 75 (3) flange adapter for mating to 3" ANSI, DIN 65 PN10 and JIS 10K3B flanges. SITRANS LU180 Optional flange adapter optional flange adapter, dimensions in mm (inch) Siemens FI 01 News 2016 4/3

Dimensional drawings, Threaded 53 (2.0) 91.5 (3.6) Electronics 160.6 (6.3) 122.7 (4.8) 104.5 (4.1) 234.6 (9.2) Mounting Thread Sensor 87 (3.4) 83.3 (3.2), dimensions in mm (inch) 4/4 Siemens FI 01 News 2016

, Sanitary Electronics 239.2 (9.4) Mounting thread 73.0 (2.9) Sensor, dimensions in mm (inch) Siemens FI 01 News 2016 4/5

Schematics, Threaded and sanitary models SITRANS LU180 + 1 2 Loop instrumentation R max + V Supply 12... 30 V DC Display Program mode Alphanumeric '20' key '4' key Operation status LOE/fault Units connections 4/6 Siemens FI 01 News 2016