WG Buried Cable Perimeter Detection System

Similar documents
WG Buried Fibre Cable Long Perimeter Detection System

INTREPID Buried Cable Perimeter Intrusion Detection System

INTREPID Buried Cable Perimeter Intrusion Detection System

Fiber Optic Cable Fence Disturbance Sensor

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

WG Railway Security Protection System

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

7638 Standish Place Derwood, MD Tel: (301) Fax: (301) Page 1 of 12. Website:

Product Specification

INTREPID Perimeter Intrusion Detection System

SL-3 Vibration Sensor line A&E Specifications Page 1 of 12 SL-3 AE v doc

Product Specifications

Buried ported coaxial cable outdoor intrusion detection system

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

INTREPID SINGLE-PLATFORM PERIMETER INTRUSION DETECTION AND MONITORING SYSTEM

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150

Presented By. BEI Security

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X

Architectural and Engineering Specification for a Hybrid Perimeter Intrusion Detection and Intelligent Lighting System.

Perimeter Intrusion Detection System

Taut Wire intrusion detection sensor (TWIDS)

4120 Fire Alarm Network Reference

Airport Perimeter Security

G-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System

Praetorian Fibre Optic Sensing

Pipeline Intrastructure Monitoring for Third-Party Interference Detection

Section PERIMETER SECURITY SYSTEMS

PROVEN PERIMETER PROTECTION NEW SINGLE-PLATFORM SIMPLICITY.

Architectural and Engineering Specification for a Fiber Optic Pipeline Integrity Monitoring System. FiberPatrol FP7000

Praetorian Fibre Optic Sensing

Committed to security

Intrusion. Outdoor protection perimeter

FOSS. Fiber Optic Stress Sensor. Kyungi Do, Korea Catalog

Innovative protection that combines power and flexibility

FlexZone SIX STEPS TO AFFORDABLE PERIMETER PROTECTION EASY TO INSTALL LOW TOTAL COST OF OWNERSHIP HASSLE-FREE OPERATION & MAINTENANCE HOW-TO GUIDE

Frequently asked questions: Intelligent Transmitter Series

Praetorian Fibre Optic Sensing

WG Container & Cargo X-Ray Scanning Portal

INTEGRATED PERIMETER SECURITY SOLUTIONS

The system can be easily relocated by a standard container truck., and re-commissioned by trained engineers typically within a 72-hour period

Product Specifications

WG Entire Truck & Cargo X-Ray Scanning Portal

The Fiber SenSys Perimeter Intrusion Detection System From JM Fiber Optics!

Perimeter security using Fibre optics

1 UL 864 Compliance. 2 Product Overview. Network Communications Module NCM-W/F Product Installation Document. 1.1 Products Subject to AHJ Approval

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

Multi-layered Perimeter Protection Systems Quality detection systems for high security sites

STRIKE GUARD DELIVERS:

Open-area Smoke Imaging Detection (OSID)

RaySense. Fiber Optic Distributed Vibration Sensing (DVS) for Pipeline Security and Leak Detection

Intrusion Outdoor Protection Perimeter

Alarm annunciation, control and communication systems

Fire and Gas Monitoring Panel ST7-HV

ADPRO PRO Series by Xtralis

Introducing the innovative ipids Indoor Outdoor Detection System MANUFACTURING SECURITY SOLUTIONS

CCU Family of Modules

Microphonic Cable Fence Disturbance Sensor (multiplex version)

For Complete Fire and Gas Solutions

HART XL High Sensitivity Smoke Detection

EOTec 2C32 Installation Guide

The. Long Beach, California August 14-17, Solutions Network. Physical Security PERIMETER SECURITY TECHNOLOGIES. Leon Snyman GVI Security, Inc.

Technology Today. Raytheon s Command, Control, Communications and Intelligence Core Market Delivering Operational Advantages for Our Customers

ACTIVE INFRARED BARRIER

FiberSensor Fiber Optic Intrusion Detection System (IDS)

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*

600 Range Dialer Installation Manual. Version 1.0

SECURITY SYSTEMS. ipatrol. Unattended ground sensors. indracompany.com

TW-8000 TAUT WIRE FENCE

INTEGRATED PERIMETER SECURITY SOLUTIONS FENCE DETECTION SYSTEMS BURIED CABLE DETECTION SYSTEMS ALARM MONITORING AND CONTROL SYSTEMS MICROWAVE SENSORS

Modular Fire Panel 5000 Series Just as flexible as your plans

Continuous, real-time detection, alarming and analysis of partial discharge events

HART XL High Sensitivity Smoke Detection

1.1 The Network Communications Module for Wire (NCM-W) Channel A & B Connections. Network Connection Ports (NUP)

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

TOTAL PERIMETER SOLUTION

Specification for On-Line UPS Battery Monitoring and Data Management System

P E R I M E T E R m i n i c a t a l o g u e

TOTAL PERIMETER SOLUTION

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

Minimal Electric Charge Detection Device for Perimeter Security Systems

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

- Basic information of Laser Scan detector

InBio X60 Series Access Control Panel User Manual

4 Channel Contact Closure SFP DIN Fiber Link System

FAAST. Fire Alarm Aspirating Sensing Technology

Integriti - Nemtek Integration Guide

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

YOUR PARTNER IN FIRE & GAS DETECTION

WAVE SEQUENCER DELIVERS:

products and services

Algo-Tec 6500/6600 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Maxline 2 Thermal Imaging Solutions for Manufacturing

SmartAlarm Annunciator

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

Very High Sensitivity Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

PERIMETER FIBRE OPTIC PERIMETER PROTECTION SNAKE

Protecting Network Data

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

Transcription:

Telephone : +44 (01295 756300 Fax : +44 (0)1295 756302 E-Mail : info@wi-ltd.com Website : www.wi-ltd.com WG Buried Cable Perimeter Detection System The WG Cable Detection Sensor is a covert outdoor perimeter security intrusion detection sensor that generates an invisible radar detection field around buried sensor cables, if an intruder disturbs the field, an alarm is declared and the location of the intrusion is determined. Targets are detected based on their conductivity, size and movement. Cables can be buried into a variety of surfaces (ground, grass and concrete) approximately 23 cm below the surface and are completely covert; the cables are robust enough for direct burial in most surfaces. The terrain-following, volumetric detection field is typically 1 metre high by 3 metres wide by up to 400 metres long. Systems can be standalone or networked for long perimeters whereby sensor cables are connected together to create a continuous perimeter. Applications Airports Communications sites Correctional facilities Critical commercial / industrial assets Government agencies and laboratories Important historic / cultural sites Military installations Nuclear materials storage Nuclear power plants Petrochemical Utilities VIP residences Standard Features Detects and accurately locates multiple simultaneous intrusions Determines the position of intruders to within ± 1 m with a 95% confidence Enhanced diagnostic tools, using WG Software Insensitive to wind, rain, snow, hail, sandstorms, fog, extreme temperatures, seismic vibration, acoustic, magnetic effects or blowing debris Low False and Nuisance Alarm Rate and high Probability of detection Operates through vegetation (grass, shrubs and trees) Sensor networking, power and data over cable reduces installation costs and provides inherent data security Up to 32 processors protecting up to 25.6 km of perimeter can be networked on one network loop Up to 7 processors protecting up to 5.6 km of perimeter for each power connection point Up to 800 metres (1/2 mile) per sensor processor Westminster Group Plc, Westminster House, Blacklocks Hill, Banbury, Oxfordshire, OX17 2BS, United Kingdom Page 1 of 6

Benefits A single processor covers twice the length of previous generation systems Alarm assessment and response can be focused exactly on the point of intrusion Completely covert Graded sensitivity cables, optimal performance Longer cables, fewer processors = cost-effective Lowest Vulnerability to defeat of any outdoor perimeter intrusion detection sensor Operates in wide range of soil conditions Site aesthetics left unchanged Tamper proof WG Network enhanced communications Ranging Technology Benefit Flexibility for any environment Minimal sensor downtime Reduced installation costs Simplifies troubleshooting Source of nuisance alarms accurately located Support analysis Uniform detection field reduces nuisance alarms Ranging Technology Features Calibrated thresholding, separate threshold per metre of cable Pinpoint target location Precise diagnostics - locate faults and sources of nuisance alarms Simplified installation - fewer constraints, installation via cable plough possible Software zoning - up to 50 zones per processor, easily adjusted How It Works The WG Cable Detection Sensor uses ported coaxial sensor cables to create an invisible electromagnetic detection field; the cables are designed with apertures in the transmit cable s outer conductor which allow energy to escape and be received by the corresponding parallel receive cable. The system uses a coded pulse signal technique (patent pending) to determine the exact intrusion location, which can identify multiple intruders simultaneously. Detection is based on the intruder s electrical conductivity, size and speed. The Probability of detection for an upright 35 kg, intruder, penetrating through the detection field and moving between 50 mm per second to 8 metres per second is greater than 99%, with 95% confidence. Objects weighing less than 10 kg are rejected with a statistical confidence level of 95%. Separate detection thresholds are set on a per metre basis. Any attempt to tamper with the cables, the processor or its enclosure, causes an alarm. The WG Cable Detection Sensor calibration is simple, walking down the sensor cables while in calibration mode allows the system to automatically adjust to the sensitivity of each metre (3.3 ft.) and thus compensate for site variations. Buried cable installation has never been so easy with calibrated thresholding. Each processor can divide the perimeter protected by its two cable sets into as many as 50 alarm reporting zones, zones can be changed at any time by technical personnel using the WG software. Westminster Group Plc, Westminster House, Blacklocks Hill, Banbury, Oxfordshire, OX17 2BS, United Kingdom Page 2 of 6

Sensor Cables Sensor cables carry alarm information and low voltage power throughout the perimeter, saving installation time and money. Cables can provide bi-directional power and communications to provide full redundancy in the event that a cable is cut or damaged. Sensor Cables are available in 3 Configurations WG1 - Has transmit and receive cables buried in separate trenches and can be spaced from 1.5 to 2 metres apart, the maximum spacing results in a detection field of roughly 1 metre high by 3 metres wide. The actual field size will depend on burial depth, burial medium, cable separation and the threshold settings of the sensor, the cables are graded to extend the cables range to 400 metres in length, the longest offered by any buried cable system. WG1 comes with 30 metres of integral lead in and 20 metres of integral lead out cables, the cables can be cut to fit any application. WG1 is typically used in applications that allow for longer cables, cost savings and / or require wider detection fields compared to WG2 cable. These cables are available in active lengths of 300 metres and 400 metres. WG2 - Has transmit and receive cables in a single jacket, these cables are used in single trench or single slot applications, thus reducing installation time and expense. The resulting detection field is typically 1 metre high and 2 metres wide, the actual field size will depend on burial depth, the burial medium and the threshold settings of the sensor. WG2 cables are offered in 50 metre increments up to 200 metres. WG3 - Has transmit and receive cables buried in separate trenches and can be spaced from 1.5 to 2 metres apart, the maximum spacing results in a detection field that is typically 1 metre high and 3 metres wide. The actual field size will depend on burial depth, burial medium, cable separation and the threshold settings of the sensor. WG3 cables are offered in 50 metre increments up to 200 metres. WG3 is typically used in applications that require wider detection fields compared to WG2 cable but do not require longer WG1 sensor cables. Software We have an easy-to-use software tool that provides real-time feedback for use during calibration and setup. It is Windows based and can be used on a personal desktop or laptop computer. It is connected directly to the processor. This eliminates the need for specialised electronic measurement equipment, greatly reduces the configuration time and effort, and facilitates factory support with its enhanced diagnostic tools. WG Network The processors can communicate alarm, status, and configuration information to and from a central control point using an integral networking capability referred to as WG Network. WG Network uses a loop topology with separate Transmit and Receive point-to-point links between each processor or other connected WG Network-compatible equipment. WG Network is designed to be polled from both ends of the loop, thus providing redundant data paths to the field equipment. Point-to-point links can be RS-422, single or multi-mode fiber, or over the sensor cables. The data signal is completely regenerated at each node in the loop to ensure proper signal integrity and reliable data transmission. Westminster Group Plc, Westminster House, Blacklocks Hill, Banbury, Oxfordshire, OX17 2BS, United Kingdom Page 3 of 6

Running WG Network over the same cables as WG sensors saves costs by eliminating the need for a separate perimeter network and provides an inherently tamper-proof communications path. Communications over WG Network is managed by a Windows XP-based PC running WG Network Manager software, this controls network communications and passes alarm and status information to a control and display system. The interface between the PC hardware and WG Network-compatible field units is provided by the WG Network Interface Unit (WG NIU), the WG NIU is a 1U rack-mountable unit and provides the choice of our software, Ethernet, and RS-232 for connecting to the PC. Specifications Performance False Alarm Rate (FAR) - Fewer than 1 per zone per month alarms from unknown causes with full visual assessment Nuisance Alarm Rate (NAR) - Site dependent Probability of detection - Optimized for the detection of an upright 35 kg, or larger person moving between 50 cm per second to 8 m per second, with a probability of detection of 99% with 95% confidence. This is based on penetration of the intruder through the detection zone Auxiliary Power Supply Accepts 18 to 56 VDC Output 12 VDC, 150 ma WG Network Repeaters for Long Network Runs Accepts 10-52 VDC Built-in battery charger Multi-mode fibre to multi-mode fibre RS-422 to multi-mode fibre RS-422 to RS-422 Packaging / Environmental Processor on a base plate in a white aluminium NEMA 4 (or equivalent) enclosure: Size - H40 x W23.5 x D16.5 cm -40 C to +70 C - Relative humidity to 95% non-condensing Protective telecom enclosure accepts NEMA 4 enclosure: Size H98.4 x W42.5 x D27.3 cm, Light green enamel over steel - Protection IP33 Sensor cable WG1 Active cable length 400 metres or 300 metres Cable jacket diameter 12.07 mm Contiguous graded design with lead-in, active cable and lead-out Each cable set comes with a kit of 6 TNC connectors and 40 ferrite beads for field installation Lead-in length 30 metres Lead-out length 20 metres Two pairs of sensor cable per processor (A and B) Westminster Group Plc, Westminster House, Blacklocks Hill, Banbury, Oxfordshire, OX17 2BS, United Kingdom Page 4 of 6

Sensor cable WG2 Active cable lengths of 50, 100, 150 or 200 metres Cable jacket diameter 8.0 mm Contiguous graded design with lead-in and active cable (no lead-out) Each cable set comes with a kit of 4 TNC connectors and 20 ferrite beads for field installation Lead-in length 20 metres Two pairs of sensor cable per processor (A and B). Sensor cable WG3 Active cable lengths of 50, 100, 150 or 200 metres Cable jacket size 8.5 x 15 mm Contiguous graded design with lead-in and active cable (no lead-out) Each cable set comes with a kit of 4 TNC connectors and 10 ferrite beads for field installation Lead-in length 20 metres Transmit and receive cable in a single jacket Two cables per processor Cable Accessories Ferrite beads / connectors Standalone and network de-couplers Terminator kits / connector tool kits / cable repair kits Processor Main Features Alarm reporting: Up to 50 functional segments per cable, Up to 50 alarm reporting zones per processor Auxiliary inputs: 2 supervised inputs, Expandable with universal input card Direct digital receiver Lightning protection: Tranzorb and non-radioactive gas discharge devices on all I/O ports Relay outputs: Alarm A, Alarm B, Supervision, Fail - Form C, 1.0 A 30 VDC max - Expandable with relay output card USB port Processor Options RS-422 Communications Card Every processor in a network configuration requires a communications card Mounts on processor expansion header Supports two RS-422 (4-wire) data paths True regeneration of signal (removes distortion at each node) Fibre Optic Communications Card Every processor in a network configuration requires a communications card Mounts on processor expansion header Multimode card fibre card operates at 820 nm, comes with ST connectors and is compatible with 50/125 μm, 62.5/125 μm, 100/140 μm, and 200 μm HCS multi-mode fibre Multimode fibre optic communication card allows distances of up to 2.2 km Single mode fibre card operates at 1310 nm, comes with ST connectors and is compatible with 9/125 single-mode fibre Single-mode fibre optic communication card allows distances of up to 10 km Supports two fibre optic data paths or one fibre optic data path and one RS-422 path True regeneration of signal, removes distortion at each node Westminster Group Plc, Westminster House, Blacklocks Hill, Banbury, Oxfordshire, OX17 2BS, United Kingdom Page 5 of 6

Input / Output Card Mounts on processor expansion header Relay output card: 8 Form C relay outputs (1.0 A, 30 VDC max) The WG processor can accept 1 optional input / output card in addition to a communications card Universal input card: 8 inputs with configurable thresholds and supervision modes WG Network Alarm data including pinpoint target location Diagnostic data to support remote UCM operation Facilitates fail safe communication Point-to-point interconnection provides reliable communication no signal degradation as with multidrop networks WG Network Interface Unit reliable lightning protected computer interface WG Network Manager - software interface to head-end Security Management System General Accessories 12 V outdoor-rated single processor supply 48 V indoor-rated dual redundant network power supply 48 V outdoor-rated network power supply Lightning arrestor kit Westminster Group Plc, Westminster House, Blacklocks Hill, Banbury, Oxfordshire, OX17 2BS, United Kingdom Page 6 of 6