USER MANUAL PLEASE READ THROUGH ALL INSTRUCTIONS BEFORE USE ANY FURTHER QUESTIONS PLEASE CALL OUR TECHNICAL HELP LINE:

Similar documents
Please take time to carefully read through these guidelines before using your Kamco pump.

Please take time to carefully read through these guidelines before using your Kamco pump.

Please take time to carefully read through these guidelines before using your Kamco pump.

RHO-FLUSH 1000, RHO-MAG & RHO-HAMMER Operating & Maintenance Instructions

Jetflush 4 Instruction Manual

JetFlush C40 & C90 Power flushing unit

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

CalMag Heating Pack Installation Instructions

M07. Wunda Premium Manifold. Before you start: Check the contents THE BRAND YOU CAN TRUST

Greenstar System Filter

Thermostatic Concealed Shower Valve

FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3

Kamco. Issue: March 2008 Section C FAQ about Power Flushing Page C.1 SECTION C FREQUENTLY ASKED QUESTIONS ABOUT POWER FLUSHING

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

INSTALLATION & TECHNICAL MANUAL

WHAT LURKS BELOW THE WATERS OF YOUR CENTRAL HEATING SYSTEM?

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

HOT WASHER MODEL NO: KING150

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

THE OXYVENT TANK. Patent No. EP INSTALLATION MANUAL. This Manual is to be left with owner. TUV Certificate of Design Approval

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

ASSEMBLY & OPERATING INSTRUCTIONS

User and Installation Instructions. Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539

HEAVY DUTY BRASS SHOWER PUMPS

BOILER HOUSE PRODUCTS GMS

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

SEALED THERMAL STORE

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

CalMag Filter Installation Instructions

The Professional s Choice

Camping Toilet USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING & USING THE CAMPING TOILET

Installation and servicing instructions

Dual Control Concealed & Exposed Thermostatic Shower Valve

Thermostatic bar mixer valve with adjustable head Installation guide

Bath Shower Mixer

Trouble Shooting and Help Guide TT / TTB 1840

Installation Manual. Instrucciones de instalación y manual de usuario 1

SAAB 99 Series H Type Engine. Installation Guide Silicone Cooling System Hoses. Classic Silicone Hoses

Aqueous Thermostatic Surface Mounted Bar Shower Valve With Fast Fit Connections

INSTRUCTION MANUAL (English version) Water still

Self-help Temperature Adjustment

Artisan Thermostatic Bath Filler

The Professional s Choice

INDUSTRIAL VACUUM CLEANER WITH AUTO START/STOP

Trials of Vexo inhibitor in domestic central. heating systems

DOMESTIC WATER RECORDS

Installation Instructions. Hansgrohe S 15721XXX

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

SINGLE LEVER CERAMIC DISC MANUAL SHOWER VALVE

DOMESTIC STEAM GENERATOR Installation Instructions

INTADUO THERMOSTATIC BATH/SHOWER MIXER

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

CPC-180-ABNAB. 180 litres, 535mm x 1550mm high

48 MaxxAir Portable Evaporative Cooler Owner s Manual

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

Pedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

IntaKlean Installation & Servicing Instructions IKMF22 and IKMF28

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

ADVANCE ECB ELECTRIC COMBINATION BOILER

Dene Bath Shower Mixer

User Guide. Please read carefully before use. Your Hoover Guarantee. Your Hoover Guarantee. Contents. IMPORTANT Safety Reminders

Installation Instructions

Gas Fire Patio Heater Q9

POWER WASHER MODEL NO: JET 9000 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING: Do not use the machine without reading this manual PART NO:

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

Dove Eco thermostatic bar mixer shower

100 FLUEBOOST

Horne Engineering Ltd INSTALLATION, COMMISSIONING, OPERATING AND MAINTENANCE INSTRUCTIONS

Pear Kitchen Sink Tap

ADVANCE ELECTRIC THERMAL STORE

Z-800II / Z-1000II / Z-1020 Fog Machine User Manual

Choosing the Right Pump

GIRTON CABINET WASHER MODEL 794A

Schuco SS-TC/SC Cylinders

AIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

STEAM WALLPAPER STRIPPER MODEL HTW5

Installation and Servicing Instructions. Alpha FlowSmart

Panel Radiators. Installation and operating instructions. ThermaRad Classic.

2 INSTALLATION OPERATION TECHNICAL SPECIFICATIONS COMPONENTS FUNCTIONS REPAIR Series TS14/TDS14/PL138

INTA ION MODERN BAR / BATH SHOWER MIXER CP

Installation Instructions. Starck

OWNER S GUIDE SEQUENTIAL THERMOSTATIC SHOWER VALVE. 150mm Inlet Pipe Centres. Shower Control. Handles and. may differ depending.

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Atmos EasySolar. Installation Instructions for. In-roof and flat roof installation with flat plate collectors

ELECTRIC ASHCAN MODEL NO: ASHVAC1200 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

Installation & User Instructions

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual

Tempest TP550/206 Petrol Pressure Washer

Sip Vacuum Cleaner 1400/35 Wet & Dry

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

For commercial & industrial systems. Large volume dirt collection capacity

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

Method Statement. General Site preparation by others: Preparation for screed system by others: Preparation for plate system by others:

WHHR Midi & Midi Lite

Installation Instructions & Maintenance Guide 6 Refit Nuts (19) and tighten.

Transcription:

USER MANUAL PLEASE READ THROUGH ALL INSTRUCTIONS BEFORE USE ANY FURTHER QUESTIONS PLEASE CALL OUR TECHNICAL HELP LINE: 0870 428 0075

CONTENTS Page 2 - Unpacking Page 3 - Heating system preparation and tips Page 4 - Connections and controls Page 6 - Connecting to heating system Page 7 - Power flushing procedure Page 9 - Technical data and safety Page 10 - Spares and accessories

UNPACKING Thank you for purchasing the Flowclean Plus power flushing and descaling pump, designed to flush central heating systems and remove sludge, corrosion and scale build-up, curing circulation problems and unwanted boiler noise, leaving a more efficient and protected heating system. Please carefully remove your Flowclean Plus from the packaging and check the contents as follows: Flowclean Plus pump with transport trolley Carry case for hoses and fittings Magnetic inline filter (Supameg Compact) System connection fitting kit and chemical funnel Quick guide instructions 2 x 3 metre flow and return hoses 2 x 3 metre dump and overflow hoses Any shortages should be reported in writing direct to Anton within 3 days of receipt Additional spares and accessories are available, see page 10 Page 2

HEATING SYSTEM PREPARATION AND TIPS Always run heating system prior to power flushing to establish the problem areas such as cold spots on radiators or slow circulation, you can then make sure the strongest concentration of chemicals are directed to these problem areas. Before power flushing the system it is important to check the following: All radiator valves are fully open, both sides of radiator. Thermostatic rad valve heads should be removed and check the pins are not stuck down. Isolate electrical supply to circulating pump, regardless of whether or not this is the location for connecting the Flowclean pump to the heating system. Check that all zone valves are set to manual open and that if any anti-gravity check valves are fitted to the system, these are temporarily removed or by-passed to allow flow reversing action to be used, any bypass should also be closed. When flushing a vented system you will need to cap off both the cold feed and vent to avoid overflowing of the feed and expansion tank, in some cases you can create a temporary loop, connecting cold feed and vent together, which will then include these pipes in the flushing process. Please do note that capping off or looping pipes, by-passing check valves etc are temporary measures and will need to be reinstated after the power flushing procedure is finished. The dump hose should run into a foul sewer; a toilet, gully or drain are commonly used. Care should be taken as contaminated water may well stain different surfaces. During the dumping process, if the mains water going in via the cold water inlet tap cannot keep up with what is being dumped out, stop dumping and allow water to return to required level: Do not adjust or restrict dump valve to try and compensate. Handy tips Your Flowclean pump is compatible with all approved chemicals, however it is important to make sure the correct chemicals are being used on the system you are working on, take care and read through chemical instructions carefully, aluminium heat exchangers, galvanised or stainless steel pipes will dictate which chemicals are suitable. If an acid based descaler is used then the system, including the Flowclean pump must be neutralised with the suggested neutralising agent prior to the final flush through with cold water. At all times during the flushing procedure the tank filling cap must be left off in order to allow the exhaust of acidic vapour created by the cleaning process. Maintain vigilance on the amount of foam produced. Do not overfill the tank by exceeding the maximum level marked clearly on the side of the tank. It is good practise to use waterproof dust sheets and replace end caps on hoses after use to prevent any unwanted spillages. In order to maintain continued flushing pump efficiency and reliability, it is of paramount importance that all equipment is thoroughly washed with clean water after every use. The flow diverter valve is situated on the top of the tank directly over the chemical fill point, the lever when in the correct position points in the flow direction set. (See page 5 for further detail) Page 3

CONNECTIONS AND CONTROLS Dump hose connection Left hand valve (Flow) Right hand valve (Return) Overflow hose connection Return hose connection Flow hose connection Cold water inlet tap Return hose connection 3 position valves Dump - Upward Closed - Horizontal Recirculate - Downward Please note correct position of drain tap on magnetic filter, fitted using swivel coupling supplied to the return hose connection (right hand side) Page 4

CONNECTIONS AND CONTROLS Power On-Off switch The flow diverter valve points in the direction of flow Chemical fill point (funnel provided) Max Min Min & Max level indicators Page 5

CONNECTING TO HEATING SYSTEM Feed and expansion tank Cap off cold feed and expansion pipe or create temporary loop on vented systems. Mains cold feed Cylinder Connect at pump valve connections, this method is most commonly used. Zone Valve Connect at radiator valve connections, this method is most commonly used where a combination or system boiler is present and pump access is difficult. Circulating Pump Bypass Boiler Connect at boiler connections, this method is normally used when a new boiler is being fitted. Page 6

POWER FLUSHING PROCEDURE Please note: Supameg Magnetic in-line filter maintenance During the cleaning process you will need to keep your eye on the in-line magnetic filter as this will attract iron oxide particles during the procedure and gradually become choked. To empty simply turn off power switch to unit, set right hand valve (return) to closed position (make sure flow direction of water is returning down the return hose) remove the magnet from top of the filter, open the small drain tap over bucket with small length of hose attached, turn on power switch and drain debris into bucket. Once completed turn off power switch, close drain tap, replace magnet, set right hand valve (return) back to recirculate and continue with cleaning procedure. (Please refer to instructions provided with Supameg for further information on use). Step 1) System preparation Isolate power to heating. If the system to be cleaned is vented, firstly you will need to cap off the cold feed and the vent pipe or create a temporary loop. These will obviously need to be reinstated after power flushing. (See page 3 for further detail). Step 2) Flowclean connection Connect your Flowclean pump to the heating system, most commonly done at the circulating pump or by taking off a conveniently positioned radiator. Connect all hoses, flow & return, dump, overflow, cold water inlet and magnetic filter, isolate power to circulating pump (see pages 3 & 6 for further detail). Step 3) Valve preparation To ensure maximum flow rate throughout the system, open all the radiator valves and set any zone valves to manual open. Check for anti-gravity check valves (see page 3 for further detail). Step 4) Start cleaning Firstly make sure your tank is approximately 5cm above minimum level indicator with clean water, using the water inlet tap. Make sure both valves are set to recirculate, now you can switch on your Flowclean pump. Leave circulating for approximately 15 minutes, regularly reversing the flow. Step 5) Dump procedure Now dump initial contaminated water from system. Set right hand valve (return) to dump position whilst making sure your water inlet balances with what you are dumping out, maintain water level in other words. Continue dumping until dump water runs clear. Step 6) Back to recirculation & adding chemical Now set right hand valve (return) back to recirculate and turn off water inlet valve, continue to recirculate with all radiator valves open. Now add flushing chemicals to system using your chemical funnel on the front of your tank. Step 7) Heating water To assist with the power flushing process (if achievable) fire up the boiler and heat water to approximately 50ºC, (making sure that electrical supply to pump has been isolated) be sure not to leave boiler on continuously. Continue to recirculate water through the whole system for a further 15 minutes, regularly reversing the flow. Page 7

POWER FLUSHING PROCEDURE Step 8) Individual radiator cleaning For best results all radiators should now be cleaned individually. Turn off all radiator valves on system apart from furthest radiator, continue to recirculate through individual radiator for 5-10 minutes, regularly reversing the flow. (obviously always making sure at least one radiator is fully open at any one time). Step 9) Individual radiator cleaning continued Now turn off furthest radiator and move to next one, repeating (Step 8) on all radiators, working your way back toward your Flowclean Plus. Once completed turn off boiler if you haven't already done so. Step 10) Individual radiator dump Once all radiators have been individually cleaned then start dumping individual radiators in reverse of how you cleaned them. Again make sure you maintain water level and continue dumping each radiator until dump water runs clear as in (Step 5). Step 11) Neutralising system After the dumping process is complete, turn valves back to recirculate on Flowclean pump and turn off water inlet tap. Make sure all radiators are now open, to return to full system circulation. Now add neutralising agent to system, again using your chemical funnel on the front of your tank. Leave circulating around full system for 15 minutes. Step 12) Final dump procedure and ph test With all radiators still open complete final dump procedure (as in Step 5), maintaining water level and continue dumping until dump water runs clear or for approximately 10-15 minutes. You will now need to test the ph levels to check dump water is now neutral, this should read the same as a sample from the mains water supply to the building. ph paper or electronic ph meters can be used. Step 13) Adding inhibitor / system protector You can now add your inhibitor / protector to the system, either using your chemical funnel at the front of your tank or injecting into a radiator or open pump valve. (Please note you may need to drain a little water out of system to achieve this). Step 14) Final procedure Leave your Flowclean pump circulating for a further 10 minutes before disconnecting it and returning system back to normal, in other words reinstate cold feed and vent pipe, make sure feed and expansion tank is cleaned, replace pump or radiator, fully vent and test system, check for leaks and return all valves to original position. Page 8

TECHNICAL DATA AND SAFETY Dimensions: W43 x D48 x H56 (cm) Weight: 18 KG with transport trolley Tank capacity: 37 litres Compatible with all approved chemicals Working fluid temperature up to 70ºC Efficient cleaning up to 20 radiators Flow rate: 5,400 ltrs/hr max 0.45 HP motor with IP54 protection Max working head: 2bar In order to maintain continued flushing pump efficiency and reliability it is of paramount importance that all equipment is thoroughly washed with clean water after every use. 12 Months parts and labour warranty subject to fair wear and tear and no misuse. The manufacturer and distributor reserve the right, that in the event of a fault claim they will repair or replace accordingly at their discretion. NOTE: - These notes are for guidance only and in no way will any claims for any damages be entered into in any way whatsoever, however caused. SAFETY TIPS As with all large or heavy goods, care should be taken to prevent injury. Always follow safety guidelines laid out in the chemical manufactures instructions. It is recommended that a RCD (residual circuit device) is used. Regular inspection of power lead and plug is strongly recommended. Page 9

SPARES AND ACCESSORIES Order code: AFEH kit AFHEA AFPHA AIRG AA15/HDH Bahco 2971G Description: 3mtr hose extension kit with straight connector and end caps Plate heat exchanger adaptor Circulating pump head adaptor Laser infra-red digital thermometer with belt pouch Liquid probe (can be used with AIRG thermometer above) Pump valve Plier Page 10

Anton Industrial Services Ltd Unit 6 Park House 15 23 Greenhill Crescent Watford Business Park Watford Hertfordshire WD18 8PH Tel: 0870 428 0075 Fax: 0870 428 0076 Email: sales@anton-group.com www.anton-group.com