CONDAIR ESCO. Live steam humidifier with 100% steam tight rotary valve. Humidification and Evaporative Cooling

Similar documents
CONDAIR ME. In-duct evaporative humidifier and cooler Very low energy operation. Humidification and Evaporative Cooling

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

CONDAIR EL. Electrode boiler steam humidifier Easy maintenance with replaceable cylinders. Humidification and Evaporative Cooling

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

Condair Esco Technical Documentation

The SKD direct steam injection system uses low pressure steam from an in-house boiler to humidify the air.

READ AND SAVE THESE INSTRUCTIONS

STEAM TO STEAM HUMIDIFIER

Condair Esco. Steam humidification system INSTALLATION INSTRUCTIONS EN 1310

The SKE humidifier generates mineral free, odorless, sterile steam without the replacement cost associated with electrode cylinders.

The SK300 humidifier generates mineral free, odorless, sterile steam without the replacement cost associated with electrode cylinders.

The SK300 humidifier generates mineral free, odorless, sterile steam without the replacement cost associated with electrode cylinders.

SKG Advantages. Typical Applications. Typical Installation

Steam Injection. Humidification system

Insty-Pac Steam Humidifiers

Steam Injection Humidifiers for use with steam boilers PRODUCT CATALOG

STEAM TO STEAM HUMIDIFIER

Steam Injection Humidifiers for use with steam boilers PR0DUCT CATALOG

Proven features for humidification in ventilating and air-conditioning systems

Key benefits. Why Condair CP3?

Getting Rid of Scale. Nortec RS Series Steam humidifier with patented scale management. Humidification and Evaporative Cooling

INTELLIGENT HUMIDIFICATION. Two adiabatic humidification methods intelligently combined Condair DL. Humidification and evaporative cooling

GAS FIRED HUMIDIFIER. Advantages. Typical Applications. Typical Installation

RESISTIVE STEAM HUMIDIFIER

Atomizing Nozzle Humidifiers. Designed for Air Handling Systems, and Manufacturers, Processors and Distributors of Humidity Sensitive Products.

High-Pressure Atomizing System

GAS FIRED HUMIDIFIER. Advantages. Typical Applications. Typical Installation

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

JETSPRAY. Compressed air and water spray humidifier Guaranteed drip free. Humidification and Evaporative Cooling

HYGIENE AND SERVICE. The Pur water treatment system

State of the Art. Exceptional Reliability

heatersteam unprecedented precision and reliability

Condair Mk5. Getting rid of scale. The steam humidifier with scale management. Low maintenance. Reliability. And superior control accuracy

Advantages. Evaporation Chamber. Evaporate water, not money! No tools required. Limits lifting and simplifies handling

Double Intelligence Two adiabatic humidification methods intelligently combined. Humidification and Evaporative Cooling. humidity.

Best Humidifier Guide. Nortec s Guide to the Best in Humidification. Humidification and Evaporative Cooling

humifog Pressurized water humidifi ers

Steam Injection Humidifiers for use with steam boilers. Installation, Operation, and Maintenance Manual

QUALITY STEAM. Electrode Steam Humidifier Condair EL. Humidification and evaporative cooling

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Air Handling Units. T F E.

Tried, true, and trusted for over 40 years. EL Series Electrode Steam Humidifier. Humidification and Evaporative Cooling. humidity.

Direct Room Humidifiers. Humidification and Evaporative Cooling. humidity.com

MFP14 Automatic pumps. for condensate and other industrial fluids

HumidiPack,HumidiPackPlus and HumidiPackPlus CF Steam Humidifier Systems

Humidity matters! CAREL solutions for your humidification needs. carel.com. air humidification systems. isothermal and adiabathic humidification

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

Modulating Controls. Principle of Operation

IRRIGATION EQUIPMENT LTD. The Perfect Solution for Water Filtration and Irrigation Problems

Steam Injection Pressurized Steam Humidifiers. Installation, Operation, and Maintenance Manual

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Key benefits. Why Condair Dual2?

Pressure Steam Humidifiers. Designed to deliver reliable humidity from facility steam boilers. Live Steam

Für Compacting alle Einsatzgebiete. Raumlufttechnik. High Pressure Humidifier and Airwasher Type HPH. Power Screw Type CPS. der dischargeoffinedust

LTG High Pressure Humidifier and Airwasher

STEAM TRAPS

ORBIT WING THE BENEFITS SUMMARISED A COMPARISON. MICRO DROP duct humidifier Additional standards:

PUT WASTE HEAT TO USE. with our gas-heated steam humidifier, Condair GS. Humidification and evaporative cooling

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

Shredders Made in China

Humidification Systems Product Guide

"ER" Series Electric Humidifier

Cool, Clean and Comfortable Nortec HP-Series. Adiabatic In-Duct High Pressure Humidification System... Simply Awesome

Pressure Steam Humidifiers LS SERIES. humidity.com

GS Series. Gas Steam Humidifiers. Designed for air handling systems and for areas requiring individual humidification control

Compact Rack Type Dishwashers

Leading Humidification Innovation... Once Again. Nortec s GS Series Condensing High Efficiency. Humidification and Evaporative Cooling CONDAIR GROUP

CONTENTS. Page 1. THE DRYPAC SYSTEM - CUSTOM MADE 1 2. PRINCIPLE OF OPERATION 2 3. CONTROLS 4 4. FLEXIBILITY 6 5. DRYPAC OPTIONS 7

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

VAPORSTREAM. Electric-to-Steam Humidifier. With Vapor-logic controller Web-enabled access I nteroperability via Modbus or optional BACnet or LonTalk

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

NH Series Electric Steam Humidifiers

heatersteam unprecedented precision and reliability

MFP14 Automatic pumps for condensate and other industrial fluids

470 Series Stamped Stainless Steel Pumps

THE SIX STEPS OF HUMIDIFICATION DESIGN

Coarse Coal Centrifuges. VM1650 is the world s largest capacity Coarse Coal Centrifuge

Steam Injection Pressurized Steam Humidifiers. Installation, Operation, and Maintenance Manual

Mastering the elements

NH Series. Electric Steam Humidifiers. Designed for installation flexibility while maintaining precise humidification control

Our Know-How. Your Peace of Mind. Steam Solutions

Safety vacuum drying oven for flammable solvents

COGEIM COGEIM EQUIPMENT MAINTENANCE AND REFURBISHMENT A NECESSARY CHOISE Number 1 filter-dryer supplier in the world

"SXDDR" Series Steam Heat Exchanger Humidifiers

EFFICIENT COOLING. Evaporative Cooler Condair ME. Humidification and Evaporative Cooling

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Armstrong Cool-Fog Systems

Custom Duct Heaters. Special Applications

IntrCooll. Cool large buildings at 80% lower running costs

CONTACT US. For more information,

Refrigeration dryers for energy efficient compressed air quality

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

AlfaNova the first fusion-bonded plate heat exchanger. A product brochure for AlfaNova within Industrial Refrigeration

Spray Rinse & Steam Handling

Centeral Station Air Handling Unit

BINDER Scientific Product Catalog

Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS

Transcription:

CONDAIR ESCO Live steam humidifier with 100% steam tight rotary valve Humidification and Evaporative Cooling

Patented precision nozzles ensure condensate-free steam Inner nozzles draw steam from the middle of the distribution pipe where it is at its hottest and driest. This guarantees that droplets aren t released into the air handling system. The nozzles are made of robust stainless steel. They are reliable and durable with no fear of leaks. Standard connection Standardised flange connections enable simple and safe connection to a steam network. Rotary disk valve is completely leak proof once closed The ceramic rotary valve is completely steam tight once closed and won t allow steam leakage to penetrate into the lance or duct. Its design also provides 0-100% modulation delivering very close humidity control. Primary and secondary condensate drain Condair ESCO Live steam humidifier

Steam distribution system Condair ESCO steam distribution systems with ready fitted connections are built in a modular fashion. With no need for thread sealants on site, they are easy to install and leak-free. Condair ESCO Model: GGG40 Steam connection unit in tried and tested cast iron GGG40 material. Condair ESCO Model: AISI304 Steam connection unit in stainless steel AISI304 for special requirements on the steam circuit. Condair ESCO humidifiers set the standard for live steam humidification. Innovative technology and quality construction provide unrivalled performance. The system can deliver up to 1,000kg/hr of pure, dry steam to an air handling unit or duct using a building s existing steam network of up to 4bar. It is ideal for use in hospitals, laboratories and manufacturing facilities where there is a ready supply of steam.

The Condair ESCO ceramic rotary disk valve in open position The Condair ESCO ceramic rotary disk valve in closed position

Rotary disk valve is completely steam tight when closed and offers 0-100% modulation The Condair ESCO s ceramic rotary disc valve provides 0-100% modulation and eliminates the problems associated with vertical stroke valves. Due to this, the valve is capable of accurately delivering a linear output throughout the entire regulating range. When closed, the valve is absolutely steam tight and prevents any steam from penetrating the steam lance when the unit is switched off. This avoids unwanted condensation occurring after steam leakage. Minimal torque and optimum reliability Unlike vertical stroke valves that need to push against the pressure of the steam supply to open, the Condair ESCO s rotary valve requires minimal torque to turn the valve and direct power transmission. This design is energy efficient and guarantees optimum reliability. It also allows the actuator to be compact. Removable particle strainer Ceramic rotary disk valve Drive shaft Condensation separation chamber Primary condensate drain

Dry steam distribution with short evaporation distance Short evaporation distances are crucial for reliable and hygienic steam humidification. The steam should never come into contact with components within the air handling unit. This would result in wetting, corrosion and hygiene risks. Condensate-free steam with patented humidification nozzles Dry steam delivery is guaranteed by the tiny nozzles that are located inside the Condair ESCO s steam lance. The steam is only taken from the centre of the lance, where it is at its hottest and driest. This provides a very short evaporation distance following release into the airstream. As condensation only gathers around the internal walls of the steam lance, these tiny nozzles prevent condensation from being introduced to the duct. The condensation that does form inside the lance is safely channelled away by the secondary condensate drain. Instant humidification This innovative system eliminates the need to pre-heat the lance with an exterior steam jacket to avoid condensation. Heated steam lances can add up to 4 C to a duct and by removing this element, the Condair ESCO saves energy. Also, live steam humidifiers with jacketed steam lances need to reach temperature before steam can be released into the lance. The Condair ESCO will start to release condensationfree dry steam on start-up, saving time and offering excellent control. Patented inner nozzles Customised solution The ESCO humidification system offers a choice of steam distribution pipes, depending on the required absorption distance and duct dimensions. Condair ESCO DL40 With one, two or three horizontal steam distributors the DL40 is flexible and can be adjusted to suit the duct. Model: Condair ESCO DL40 Condair ESCO DR73 For high steam duties or short evaporation distances the DR73 is ideal. The steam distribution system is designed specifically for each project. With nozzles on both sides of the steam pipe, distribution is uniform across the entire duct. Model: Condair ESCO DR73

System overview Series DL40 with single pipe distribution Series DL40 with double pipe distribution Series DL40 with triple pipe distribution Series DR73 with vertical pipe distribution Technical data Series DL40 Size of valve Steam pressure (bar) Steam capacity max. (kg/h) Width of air duct max. (mm) Esco 5 0.2 4.0 bar 127 4,000 Esco 10 0.2 4.0 bar 250 4,000 Esco 20 0.2 4.0 bar 500 4,000 Esco 10 0.2 4.0 bar 250 10,000 DR73 Esco 20 0.2 4.0 bar 500 10,000 Esco 30 0.2 4.0 bar 2,000 10,000 Condair plc - the new name for JS Humidifiers Artex Avenue, Rustington, Littlehampton, West Sussex, BN16 3LN, UK Tel: +44 (0)1903 850200 - uk.sales@condair.com - www.condair.co.uk 10/2014