Installation Instructions. Replacement of Control Console, Part No , Safety and Installation Requirements

Similar documents
Installation Instructions VITOTRONIC 200

Operating Instructions and User s Information Manual for use by engineers and heating contractors VITOTRONIC 100 IMPORTANT

Installation Instructions VITOTRONIC 300

Technical Data Manual

Technical Data Manual Model Nos. and pricing: see Price List

Technical Data Manual Model Nos. and pricing: see Price List

Start-up/Service Instructions for use by heating contractor. VITOCELL r 300-V VITOCELL r 300-B IMPORTANT

Installation and Service Instructions SM1 SOLAR CONTROL MODULE IMPORTANT. Read and save these instructions for future reference.

Application Guide. Vitodens 100-W B1HA/B1KA Residential Boiler

Installation Instructions for use by heating contractor. VITOCELL r 300-H CAUTION IMPORTANT. Read and save these instructions for future reference.

COMBUSTION AIR SYSTEM

Installation, Operating and Service Instructions for use by heating contractor. VITOCELL r 300-W CAUTION IMPORTANT

Installation and Operating Instruction Supplement Use in conjunction with the original technical literature supplied by Riello. Riello Burner WARNING

Communication. Versatronik 581 & 581D LON Communication Gateway. Technical, Installation and Configuration Information. Cautionary Statement

Installation Instructions for use by heating contractor. VITOCELL r 100-B CAUTION IMPORTANT. Read and save these instructions for future reference.

Installation Instructions for use by heating contractor. VITOCELL r 100-V CAUTION IMPORTANT. Read and save these instructions for future reference.

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Application Guide. Vitodens 222-F B2TB Residential Boiler

Installation Instructions

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

VITOSOL. Solar hot water heating systems Flat plate and vacuum tube solar collectors

Operating Instructions and User s Information Manual VITOROND 200 WARNING WARNING IMPORTANT. Read and save these instructions for future reference.

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

COMBUSTION AIR SYSTEM Model: CAS-3

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

SC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS

8-SERIES (S,W) OIL FIRED BOILER ELECTRICAL WIRING DIAGRAMS

SC-9 Controller INSTALLATION AND OPERATING INSTRUCTIONS. SC-9 Applications CONTENTS

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

INSTALLATION INSTRUCTIONS

Control Panel Checklist

Service Instructions for use by heating contractor VITOROND 200 IMPORTANT. Read and save these instructions for future reference.

Installation, Service and Operating Instructions. Viessmann AirflowPLUS IMPORTANT. Read and save these instructions for future reference.

Installation and Service Instructions for use by heating contractor. VITOTRONIC r 200 VITOTRONIC r 300-K IMPORTANT

Q - Series Boiler. Troubleshooting Manual

JS. Bosch Remote Control

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

Technical Data Manual Model Nos. and pricing: see Price List

INSTALLATION INSTRUCTIONS

Technical Data Manual Model Nos. and pricing: see Price List

Installation Instructions for use by heating contractor. VITODENS r 222-F IMPORTANT. Read and save these instructions for future reference.

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

SYSTEM CONTROL KIT Model: CK-41P

TT /97 WARNING WARNING WARNING INSTALLATION INSTRUCTIONS

Installation & Operation Manual NCB-E Condensing Combi-Boilers

Installation Instructions for use by heating contractor

Energy Manager INSTALLATION INSTRUCTIONS. Keep these instructions with the boiler at all times for future reference

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

INSTALLATION INSTRUCTIONS

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION. Glass Panel Doors (select models) CAUTION

Operating Instructions for use by heating contractor. VITOTRONIC r 100 VITOTRONIC r 300-K IMPORTANT

Leading Word on Lag Modules

ETN-24-SUPER-SF Series

25M01A-100 to 25M01A-199 HSI Single Stage Combination Gas Valve

Installation and Service Instructions VITODENS 100-W IMPORTANT. Read and save these instructions for future reference. for use by heating contractor

Product Support Bulletin

SWEATMISER ANTI-SWEAT HEATER CONTROLLER. Table of Contents

HX Field Replacement Kit

Summer Breeze Heater Service Manual

Service Instructions for use by heating contractor

VITOSOL r DHW SOLAR PACK

be liable for any other loss or damage, whether direct, indirect, incidental or consequential.

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

CONDENSATE PUMP INSTALLATION MANUAL OFFICE PRO 10

INSTALLATION INSTRUCTIONS

Installation Instructions for Kay Chemical / Power Soak Dual Dispenser Pump (01/02/03)

Installation. Leveling

Installation Instructions for use by heating contractor

Ion Gateway Cellular Gateway and Wireless Sensors

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Installation Instructions for use by heating contractor. Vitodens Common Venting System IMPORTANT

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

Sacksafoam Heli-Case Operations Manual - Version A Issue Date: April 2017 PLEASE READ BEFORE USING

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

Installation and Service Instructions. VITOTRONIC r 100 IMPORTANT. Read and save these instructions for future reference.

INSTALLATION INSTRUCTIONS

3 Completely loosen the blue thumb screws on either side of the fuser. 4 Grasp the ends and pull straight up to remove the fuser.

Operator: Save these instructions for future use!

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

VIESMANN. Installation instructions VITODENS 200-W. for contractors

DEMA 830 Laundry Master TM Installation Instructions

PACKAGED UNITS KITS AND ACCESSORIES. 7/2011 Supersedes 5/2011

Operating Instructions VITOCROSSAL 300 WARNING WARNING IMPORTANT. Read and save these instructions for future reference. for use by heating contractor

Freeze Prevention Kit Spare part for models: 1210 ES/ESC, C1050ES, C 950 ES, 940ES, 830ES, 2400 ES, 2700 ESC, Evolution 500, Integra 500

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

11.4 Component Assembly Diagrams and Parts Lists Case Assembly

Heater for BRP Commander. Caution: Before using this product, read this manual and follow all safety instructions. Owner s Manual

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

E-Z Zone Pack 3+1 And 5+1 Boiler Manifold System

Heater Upgrade Instructions

Service Bulletin

Transcription:

Installation Instructions for use by heating contractor Replacement of Control Console, Part No. 7826 987, 7826 988 for Vitodens 100-WB1A Please file in Service Binder Safety and Installation Requirements Please ensure that these instructions are read and understood before commencing installation. Failure to comply with the instructions listed below can cause product/property damage, severe personal injury, and/or loss of life. Working on the equipment The installation, adjustment, service, and maintenance of this product must be done by a licensed professional heating contractor who is qualified and experienced in the installation, service, and maintenance of hot water boilers. There are no user serviceable parts on the boiler, burner, or control. Ensure main power supply to equipment, the heating system, and all external controls has been deactivated. Close main gas supply valve. Take precautions in both instances to avoid accidental activation of power during service work. It is not permissible to perform service work on any component parts ensuring safe operation of the heating system. When replacing parts, use original Viessmann or Viessmann approved replacement parts. Ensure that thevitodens 100 Service Instructions are referenced. Remove front cover panel and expose control C A 1. Remove the screw at the top of boiler. 2. Press down on springs at bottom of boiler and remove the front enclosure panel. 3. Flip control console down. D B 7826 988 II CA 03/2009

Removing the control unit 1.Flip control unit down and out towards you. The control unit is held in place with a spring loaded clip A. A 2.Slide unit to the left to remove. IMPORTANT The control unit has labels and stickers containing important information. Read and follow their respective instructions. 3.Tilt down the control to remove back cover (shield). 4.Release tabs on both sides of the console. 5. Expose wiring connectors. 2

Removing the control unit (continued) 6. Remove connectors. 7.Cut cable tie from the base. 8. Remove complete control console from the base (left side first). 3

Installation 1. Install new control (starting from right side). 2. Reconnect all wiring harnesses (connectors are numbered which correspond to the numbers printed on the circuit board). 3.Use two cable ties (field supplied) to secure the harness to the control base. 4. Reinstall back cover (shield). 4

Installation (continued) 5. Reinstall front cover panel. 6. Verify DIP switch settings. S1 Factory default settings for S1 DIP switch 1 Dip switch S1 DIP switch settings - S1 Dip switch number Setting Explanation 1 OFF Pump is ON during call for heat. After call for heat (RT-Terminal) is satisfied pump post-purges for 12 minutes. After DHW/external heat demand (ST-Terminal) is satisfied, pump post-purges for 1.5 minutes. ON Pump operates continuously 2 OFF Do not adjust 3 OFF Do not adjust 4 OFF Do not adjust 5

Reinstalling the control unit 1. Hook in control unit. 2. Flip control upward and lock into position. CAUTION Electrical cables may become damaged if in contact with hot components. When running and securing connecting cables on site, ensure that the maximum permissible temperatures of the cables are not exceeded. Reinstalling the front cover panel 1.Hook in front cover panel. 2.Press in bottom portion of front cover panel until it locks into position. 3.Fasten with screw at the top part of the boiler. IMPORTANT Read and follow, where applicable, the safety instructions of all labels and stickers attached to boiler surfaces. Do not remove any of these instructions. Contact Viessmann if any replacement labels are required. 6

Wiring diagram External Connections (Field Wiring) PUMP DHW PUMP 7

Viessmann Manufacturing Company (U.S.) Inc. 45 Access Road Warwick, Rhode Island 02886 USA 1-800-288-0667 Fax (401) 732-0590 www.viessmann-us.com info@viessmann-us.com Viessmann Manufacturing Company Inc. 750 McMurray Road Waterloo, Ontario N2V 2G5 Canada 1-800-387-7373 Fax (519) 885-0887 www.viessmann.ca info@viessmann.ca 7826 988 II v1.0 Technical information subject to change without notice. Printed on environmentally friendly (recycled and recyclable) paper. 8