Programmable Security Light Switch

Similar documents
18W Round LED Wall/Ceiling Light with Microwave Sensor

12W Round LED Wall/Ceiling Light with Microwave Sensor

Digital Room Thermostat with Night Set-back

360º Surface Mount Ceiling PIR Light Controller

360 Surface Mount Ceiling PIR Light Controller

360 Ceiling PIR Light Controller

Emergency Assist Alarm Kit Single Zone

5W LED Energy Saver PIR Bulkhead

60W Multi PIR Bulkhead

Surface Mount Wall PIR Light Controller. Model: PDWM1500. Installation & Operating Instructions

High Frequency Sensor

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

Model: MLSA360N. Installation & Operating Instructions. 360º Night Eye PIR Light Controller

30W LED PIR FLOODLIGHT. Model: LEDX30PIRB Model: LEDX30PIRWH

Installation & Operating Instructions

Cat. No TPT44. Installation & Operating Instructions

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS

Model: PDSM1500. Installation & Operating Instructions 360º Surface Mount Ceiling PIR Light Controller

Cylinder/Pipe Thermostat Cat. No. TRT044. Operating & Installation Instructions

Battery Powered Electronic Programmable Room Thermostat

DOOR & WINDOW ALARM INSTALLATION & OPERATING. Cat No. TG232W INSTRUCTIONS

Model: PDFM1500. Installation & Operating Instructions 360º Flush Mount Ceiling PIR Light Controller

CHIME RECEIVER INSTALLATION & OPERATING. Cat No. TLRXC1 INSTRUCTIONS

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS

Battery Powered Electronic Room Thermostat Cat. No. TRT033

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

TIMEGUARD WEATHERSAFE OUTDOOR POWER RANGE INSTALLATION & OPERATING INSTRUCTIONS

Electronic Room Thermostat Cat. No. TRT030

Electronic Frost Thermostat

BATTERY POWERED DETECTOR/ TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTXDCB INSTRUCTIONS

Professional, Rewireable, Linkable LED Lighting

Compact Movement Activated Sensor Installation Instructions

"Options" Sensor Module

Electronic Dual Cylinder Thermostat Installation Instructions

Electronic Dual Cylinder Thermostat User Instructions

Electronic Room Thermostat

Blender. Instruction manual. Model Modèle Modell Modello Modelo Malli: CR836/DR825

Illuminating. Solutions. for Energy Saving. Featuring the latest PIR Lighting solutions from Timeguard.

GI1DPC/B User Guide. Mains tungsten GLS filament or halogen lamp Min 60W Max 300W. Linear fluorescent

Lighten. the Load! MASTERS. SUPPLY! Timeguard s range of Fused Spur Timeswitches. Savings! LIGHTING. Countdown. On Demand! ALSO INSIDE THIS ISSUE

User Guide PLEASE READ BEFORE USE AND KEEP FOR FUTURE REFERENCE.

Safety! Seasonal INSIDE THIS ISSUE. Small and Powerful LED lighting Energy Saving without compromise.

60 WATT SQUARE WALL LAMP WITH P.I.R. MOVEMENT SENSOR INSTRUCTIONS

SENSA MRE DDM MR

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

Varenummer: Version:

Direct Dim Microwave Presence/Absence Detector

Performance To extend the performance and life of your jet stream generator ensure that you replace the anti-scale cartridge regularly.

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

Lantern Receiver E-997 INSTALLER GUIDE. SF-LA-BC-RX-W.qxd 13/04/ :36 Page 1

Colorado SCR. Electric Towel Radiator Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Steam generator. Two year guarantee. Ironing system

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

. w. POWERHOUSE n MOTION DETECTOR MODEL PR511 OWNER S MANUAL

CR2003 ROBERTS. 3 band Auto set PLL Synthesised Clock Radio. Sound for Generations. Please read this manual before use

User's Instructions. Alpha CB50

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

ROBERTS. FM / MW dual alarm clock radio with instant time set. Please read this manual before use

Low Level Thermal Electric Radiator. Installation and Operation Guide. Models. Type Wattage No. of Fins Size (HxWxD) (mm) Net Weight (kg)

Turbo steam iron steam/spray/shot

irad Wireless Controller

Comfigrip iron steam/spray/shot

SWITCHLITE MRE SLDM ADJ

SH3020 USER INSTRUCTIONS

Heated Display. Instruction manual. Model: CW147 / CW148

Model: Touch-RS. 1 Touch-RS

Water tank The water tank can be re-filled at any time during ironing.

Autofill counter top water boiler

PH1000T PH1500T PH2000T

Built-in Conventional Oven

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

KYROS INSTRUCTIONS MANUAL MOUNTING, INSTALLATION, STARTING AND OPERATION TOWEL RAIL

AVANT DGS. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Classic Electric Stove

Installation and User Guide. Electro-mechanical 24 hour timeswitch for controlling hot water and heating (Including Factory Replacement Units FRU)

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

LED Lighting. Solutions

Analogue Dimming Microwave Presence/Absence Detector

SHORT WAVE INFRARED PANEL DRYER

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Heat Shade. Instruction manual. Model Modèle Modell Modello Modelo Malli: DR573/DR574/DR575/DR576/DR577/DR578/DR579/ DL492/DL493/GC882/GC883

Model: GF256-A. Waffle Maker. Instruction manual

Your Blast Vac Pro. Your Blast Vac Pro

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

PTC Ceramic Heater. Instruction Manual THE SCIENCE BEHIND HEAT

QUALITY SPACE HEATERS

ESCTDEB. Electronic Dual Cylinder Thermostat* User and Installation Instructions. Patent pending

User Instruction Manual

Imperial Electric Fires

User Manual THR870CUK Programmable Thermostat

Electronic Thermostat With RF

Premium Coffee Maker With Integrated Grinder

Super. Bright. Lumens! Super. Slim!

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

Contact Details. Please note that some of the contact details on this PDF document may not be current.

iheat 25c iheat 30c iheat 35c

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

Transcription:

Programmable Security Light Switch Model: ZV210 (Single) Model: ZV215 (Double) Installation & Operating Instructions

1 1. General Information These instructions should be read carefully and retained for further reference and maintenance. 2. Safety Before installation or maintenance, ensure the mains supply to the light switch is switched off and the circuit supply fuses are removed or the circuit breaker turned off. It is recommended that a qualified electrician is consulted or used for the installation of this light switch and install in accordance with the current IEE wiring and Building Regulations. Check that the total load on the circuit including when this light switch is fitted does not exceed the rating of the circuit cable, fuse or circuit breaker.

2 3. Technical Specifications 230V AC 50 Hz This time switch is of class II construction and must not be earthed Switch Rating: Incandescent Lighting: 40W (min lamp size) 300W (max total load) Low Energy CFL: 20W LED Lighting: 20W The LED switching capabilities of this product can be increased to 200W by the addition of the Timeguard ZV900 Automatic switch load controller sold separately Minimum Depth of Wall Box: 25mm Operating Temperature: 0 C to +40 C The ZV215 double security switch will replace any conventional double or two way switch. For single switches, use the ZV210 only.

3 Manual ON/OFF switch CE Compliant Dimensions (H x W x D): 85 x 85 x 38mm Notes: Not suitable for use with Discharge Lighting This product can be used both as a normal light switch and as a security switch. When set in the security mode it will turn the lights on when it gets dark, and turn them off again for a chosen period of time up to eight hours later. This product requires to be permanently powered which is achieved through the switched Live. As such, some LED and CFL lamps may glow or flash whilst this product is in the Off status. This glow/flash can be eliminated by adding the Timeguard ZV900 Automatic switch load controller to the circuit. The ZV900 is sold separately.

late Manual ON/OFF switch (Doubles as Security Switch on ZV210) Right Hand Security Switch (ZV215 only) LED window (lights when set in security mode) Light sensing window 4 Combined security switch and hours on adjuster 8 6 2 4 early Light level adjuster Sliding cover Concealed panel NOTE: On the ZV215 DOUBLE the right hand switch (red dot) acts as the security mode.

5 4. Connections ZV215 Double Security Light Switch Security switch ON/OFF and Two Way (L1) Common (COM) 1 4 2 5 3 6 Two Way only (L2) ZV210 Single Security Light Switch Normal Switch ON/OFF and Two Way (L1) Common (COM) Two Way only (L2) ON/OFF and Two Way (L1) Common (COM) Two Way only (L2) 1 2 3

late 5. Security Function 2 early 6 8 6 4 Figure 1 ZV210 Switch Open Figure 2 Switch Closed

7 Testing Ensure that the light switch is in the OFF position. Slide down the front of the cover to expose the security controls (See Figure 1). Turn the light level adjuster fully towards the early symbol, and then turn the hours on dial clockwise until the LED window glows. Emulate darkness by covering the Light sensing window, the light will automatically turn ON after a period of up to two minutes. To revert to a normal light switch, turn the hours on dial fully anti-clockwise, lining up the dot.

8 Setting up Ensure that the light switch is in the OFF position. Slide down the front of the cover to expose the security controls. Turn the hours on dial to indicate how many hours you wish the light to remain on for, and check the LED window is glowing. Slide the cover back up. The security mode is now set and the light will automatically turn on at dusk and remain on for the number of hours you have selected. This programme will repeat itself every 24 hours. Note: If you wish to use the security switch as a normal light switch simply turn the hours on dial fully anticlockwise, lining up the dot. If you then wish to use it as a security switch again please follow the above instructions.

9 Adjustment If you find that the light switches on when it is too dark, turn the light level adjuster towards early and if the light is in operation when it is too light turn the adjuster too late. Notes: The security switch has a built-in delay function to ensure that momentary changes in the light do not switch it on. The hours shown on the dial are only approximate guides, do not expect great accuracy. Once the switch has turned on and the programme has turned OFF after the required number of hours, it is important not to allow artificial light to fall on it, followed by a period of darkness. This will fool the switch into thinking it is dark again and it will operate. Care should therefore be taken to prevent light falling onto the switch, e.g. table lamps.

10 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515. Note: A proof of purchase is required in all cases. For all eligible replacements (where agreed by Timeguard) the customer is responsible for all shipping/postage charges outside of the UK. All shipping costs are to be paid in advance before a replacement is sent out.

If you experience problems, do not immediately return the unit to the store. Telephone the Timeguard Customer Helpline; HELPLINE 020 8450 0515 or email helpline@timeguard.com Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query. For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.com www.timeguard.com 67-058-13 (Issue 4) Zerofour April 2017