Service instructions. FM443 solar module. Function module. For contractors. Read carefully prior to commissioning or service

Similar documents
Operating instructions

Operating instructions

FM458/CMC 930. Strategy module. Service instructions. For contractors. Read carefully prior to commissioning or service.

Operating instructions

Installation and service instructions

Operating instructions

Operating Instructions

Servicing instructions for heating contractors

Installation and servicing instructions

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

Operating Instructions

Room-temperature (economy/night) unit TR 212 E

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

Installation and Service Instructions SM1 SOLAR CONTROL MODULE IMPORTANT. Read and save these instructions for future reference.

FR 10 INSTALLATION & USER INSTRUCTIONS INTELLIGENT ROOM THERMOSTAT

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

Boiler controller S-Tronic Plus

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

O CRC100. Comfort Room Controller (2015/01) en

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

R. Boiler Energy Management System FW 200. Operating Instructions for the User (2010/05)

Installation instructions. Advanced Weather Compensation Controller. Sense II O UK/IE (2015/10)

RT 10 RT 10 INSTALLATION, USER INSTRUCTIONS & CUSTOMER CARE GUIDE. Order no

O CRC200. Comfort Room Controller. Installation instructions for contractors (2015/02)

Boiler controller Lambdatronic S 3200

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions

BM Programming Module. For the heating engineer Installation instructions

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Operating instructions Oil condensing boiler

VIESMANN. Installation instructions. Mixer extension kit. for contractors. Mixer extension kit. For one heating circuit with mixer

Service Instructions for use by heating contractor

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

/2010 US/CA

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

Operating instructions

INSTRUCTION FOR THE USER THC V E OIL BLU

AGS 5/5E, AGS 10/10E INSTALLATION AND SERVICING INSTRUCTIONS SOLAR PUMP STATIONS FOR SEALED SOLAR HEATING SYSTEMS AND INDIRECT FED DOMESTIC HOT WATER

COnDEnSInG BOIlERS TAU UNIT OIL USER parameters manual

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

Installation instructions

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

VIESMANN. Operating instructions VITODENS 100-W. for the system user

Operating instructions

EN Z Subject to change due to technical improvements! Operating instructions

E-COMBI EVO E-SYSTEM EVO

GREENSOURCE HYDROLIGHT AND HYDROCOMFORT

Greenstar Xtra. Installation instructions. Passive flue gas heat recovery device. For use with Greenstar CDi Compact, Si Compact and i combi boilers

Operating instruction. Remote control station WCM-FS /

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

Logamatic 4000 Modular Control System Control Units and Extended Functions

Mixer module VR 61. Operating and Installation Manual. Mixer module for VRC 430 / VRC 430f

VIESMANN. Operating instructions VITODENS 111-W. for the system user

Heating and D.h.w. Controller RVL482 Basic Documentation

G2484. Installation. - Control panel (in the panel front, on the inner wall, or on a DIN rail)

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

Connecting cable. Installation instructions (2018/04) US

ST 53.1 User s manual

Condensing Boiler RS100 Controller Training Program

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

VIESMANN. Operating instructions VITOTRONIC 200. for the system user

SUN EQUINOX HEATING SYSTEMS

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

multimatic Operating instructions Operating instructions For the operator AT, BE (de), CH (de), DE VRC 700f/4 Publisher/manufacturer Vaillant GmbH

Greenstar System Filter

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

Installation instructions. Pump Group. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)

Operating instructions THETA control unit for heating contractors. ROTEX control unit: - THETA 23R - THETA RS - THETA HEM1

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

Installation and maintenance instructions

For the operator/for the heating engineer. Operating and Installation Manual VRC 430. Weather compensator VRC 430

USER MANUAL. OPTIMA 312 ES960C circuit board

for contractors Vitosolic 100 Type SD1 For applicability, see the last page Please keep safe.

Operating instructions. For the operator. Operating instructions VRT 350. Room temperature-controlled controller GB, IE

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

CondenseSure Siphon INSTALLATION INSTRUCTIONS UK/IE GREENSTAR EXTERNAL 500ML SIPHON

Operating instructions

Greenstar 12i/24i System

Operating instructions

OPERATING MANUAL Enertronic Control System 2

Operating instructions

BWL air heat pumps BWS brine heat pumps

Operating instructions

USER'S INFORMATION MANUAL

User Manual for model

VIESMANN. Installation instructions. Extension EA1. Safety instructions. for contractors. Part no

Transcription:

Service instructions Function module FM443 solar module For contractors Read carefully prior to commissioning or service 6 720 615 516-03/2008 GB/IE

Contents 1 Safety........................................ 3 1.1 About these instructions......................... 3 1.2 Correct use.................................. 3 1.3 Standards and guidelines/directives.................. 3 1.4 Symbol key.................................. 4 1.5 Please observe these notes........................ 4 1.6 Disposal................................... 6 2 Product description.............................. 7 2.1 Inputs and outputs connection.................... 9 2.2 Installation in Logamatic 4000 control units..............11 2.3 Switch positions..............................12 3 The FM443 functions.............................15 3.1 Integration of the FM443 function module into the control unit..15 3.2 Changing operating mode.........................18 3.3 Solar consumer "1" solar circuit 1..................20 3.4 Buffer integration..............................22 3.5 Solar circuit heat meter..........................26 3.6 Pump function secondary circuit pump...............30 3.7 Heating up the pre-heat stage......................36 3.8 Solar consumer "2" solar circuit 2..................38 4 Relay test.....................................41 5 Fault log......................................43 6 Fault.........................................44 7 Monitor data...................................47 7.1 Solar consumer "1" solar circuit 1..................48 7.2 Buffer bypass circuit............................49 7.3 Solar circuit heat meter..........................50 7.4 Solar consumer "2" solar circuit 2..................51 8 Sensor curve...................................54 9 Index.........................................55 2 FM443 function module - Subject to technical modifications.

Safety 1 1 Safety 1.1 About these instructions This chapter contains general safety instructions, which you should observe during service work on the FM443 function module. Also closely observe the further safety instructions, which you can find in other chapters of these service instructions. Carefully read the safety instructions before commencing the work described below. Severe injury and even death, as well as damage to property and environmental damage, may follow if you ignore safety instructions. 1.2 Correct use You can fit the FM443 function module into control units that are part of the Logamatic 4000 control system. For the system to operate perfectly you will require control unit software version 4.17 or higher. 1.3 Standards and guidelines/directives The design and operation of this product conform to European Directives and the supplementary national requirements. Its conformity is demonstrated by the CE designation. You can view the Declaration of Conformity on the internet at www.buderus.de/konfo or request a copy from your local Buderus sales office. FM443 function module - Subject to technical modifications. 3

1 Safety 1.4 Symbol key Two levels of danger are identified and signalled by the following terms: RISK TO LIFE WARNING! Identifies possible risks associated with a product that might lead to serious injury or death if appropriate care is not taken. RISK OF INJURY/ SYSTEM DAMAGE CAUTION! Indicates a potentially dangerous situation which could lead to minor or moderately serious injuries or to damage to property. USER INFORMATION User tips for the optimum utilisation and setting of the appliance plus useful information. 1.5 Please observe these notes The FM443 function module has been designed and built in accordance with currently recognised standards and safety requirements. However, damage to property resulting from inappropriate service work cannot be completely prevented. 4 FM443 function module - Subject to technical modifications.

Safety 1 Read these service instructions thoroughly before commencing any service work on the function module FM443. RISK TO LIFE WARNING! from electric shock. The installation, electrical wiring, commissioning, electrical connection, as well as maintenance and repairs must only be carried out by a competent contractor who adheres to all current technical regulations and requirements. Observe all local regulations. RISK TO LIFE WARNING! from electric shock. Ensure that all electrical work is carried out by an authorised electrician. Before opening the control unit: Isolate all poles of the mains power supply and secure against unintentional reconnection. RISK TO LIFE from electric shock. WARNING! The risk of short circuits through unintentional loosening of the cores at the terminals between the 230 V and the low voltage must be prevented. Therefore, mutually secure the cores of each cable (e.g. with cable ties) or strip off only a very short piece of outer insulation. FM443 function module - Subject to technical modifications. 5

1 Safety RISK OF INJURY/ SYSTEM DAMAGE CAUTION! from operator error. Operator errors can result in injury and/or damage to property. Ensure that children never operate the appliance unsupervised or play with it. Ensure that only personnel able to operate the appliance correctly have access to it. DAMAGE TO THE DEVICE CAUTION! from electrostatic discharge (ESD). Before unpacking the module touch a radiator or a earthed metal water pipe to discharge any electrostatic charge in your body. USER INFORMATION Ensure that a regulation isolator is available to disconnect all poles from the mains power supply. If no isolator is available, you must fit one. USER INFORMATION Only use original Buderus spare parts. Losses caused by the use of parts not supplied by Buderus are excluded from the Buderus warranty. 1.6 Disposal Electronic components must not be disposed of with general domestic waste. Dispose of old modules correctly through an authorised disposal site. 6 FM443 function module - Subject to technical modifications.

Product description 2 2 Product description USER INFORMATION Before installing the FM443 function module, check the software version of the controller module (CM431) and MEC2 programming unit (version 4.17 or higher). Your local Buderus sales office will advise you further. You can fit only one of the FM443 function modules into one control unit of the Logamatic 4000 control system. The main function of the FM443 function module is to link a solar thermal system with one or two solar consumers (e.g. cylinders) to an existing control unit. Installing the FM443 function module makes the following functions or connection options available: Changing operating mode Integrating solar consumer "1" (e.g. DHW cylinder) Buffer bypass circuit for central heating backup Cylinder in series circuit Integrating solar heat meter (WMZ) available from Buderus as an accessory Integrating solar consumer "2" (e.g. swimming pool) Termal disinfection of the pre-heat stage Monitoring the daily heat-up of the pre-heat stage in compliance with DVGW Code of Practice 552 FM443 function module - Subject to technical modifications. 7

2 Product description 6 7 8 9 5 4 10 11 3 2 1 Fig. 1 Front panel FM443 function module 1 Switch (solar circuit 1) 2 LED "Diverter valve" in case of buffer bypass circuit (central heating backup via cylinder) 3 LED "Diverter valve" in case of buffer bypass circuit (no central heating backup via cylinder) 4 Solar circuit pump 1* 5 Cylinder 1 maximum temperature 6 "Module fault" LED (red) general module fault 7 Maximum collector temperature 8 Secondary solar circuit pump 2 or transfer or transfer pump active* 9 Solar circuit pump 2 or diverter valve 2 in solar circuit 2* position 10 Diverter valve in place of solar circuit 1 11 Switch (solar circuit selection) * LED constantly ON: Pump running (100 %) LED "flickers": Pump modulates LED OFF: Pump OFF 8 FM443 function module - Subject to technical modifications.

Product description 2 2.1 Inputs and outputs connection The low voltage terminals and the 230 V outputs are available at the rear top of the FM443 function module. Coloured labels with inscriptions matching the appropriate plugs are fitted to the strips. Plugs are colour-coded and inscribed. Designation Description Mains Power supply PSS2 Solar circuit pump 2 SU Diverter valve (cylinder 1/cylinder 2) PS2 Secondary solar circuit pump 2 Buffer bypass switching: SPB Diverter valve PSS1 Solar circuit pump 1 Tab. 1 Connections 230 V FM443 function module - Subject to technical modifications. 9

2 Product description USER INFORMATION Ensure that you connect the FPB sensors correctly and install them in their correct positions depending on the type of system circuits (buffer bypass or cylinders in series). FPB WMZ Sensor Tab. 2 Designation FR FP FR FV ZV FSS2 FSS FSK Low voltage connections Description Buffer bypass switching: Return temperature sensor Buffer bypass circuit: Buffer temperature sensor Earth connection Solar circuit return temperature sensor for heat metering Solar circuit flow temperature sensor for heat metering Solar circuit volume flow meter for heat metering Temperature sensor for solar consumer 2 Temperature sensor for solar consumer 1 Collector temperature sensor 10 FM443 function module - Subject to technical modifications.

Product description 2 2.2 Installation in Logamatic 4000 control units USER INFORMATION Position the FM443 function module as far to the right as possible in the control unit. This ensures that the heating circuits are allocated logically. The heating circuit modules should be inserted in the control unit starting from the left. Install the FM443 function module into any vacant slot of the control unit series 4000 (e.g. slot 1 4 in Logamatic 43xx). Optional slot allocation in the different control units 412x 4211 43xx 1, 2 1, 2 1, 2, 3, 4 Tab. 3 Optional slot allocation FM443 function module - Subject to technical modifications. 11

2 Product description 2.3 Switch positions SYSTEM DAMAGE CAUTION! If the switch is set to "manual" for a lengthy period, this can damage the solar thermal system or even destroy system components. Ensure that you use manual mode only for short periods. The various positions of the switch have different effects on the solar circuits or the two solar consumers. USER INFORMATION The switches should normally be in the "AUT" position. 12 FM443 function module - Subject to technical modifications.

Product description 2 2.3.1 Switch (solar circuit 1) USER INFORMATION If the switch is not in automatic mode, a message to that effect appears on the MEC2 control unit, and the "Module fault" LED on the module illuminates. Position Effect Solar circuit 1 (solar circuit pump 1) and the bypass (diverter valve) are switched off. This setting should only be used for new installations, or when carrying out maintenance or servicing. Solar circuit 1 and the bypass are in automatic mode this is the standard setting. Manual mode is enabled. Solar circuit pump 1 is switched on. The bypass is not being controlled. Tab. 4 Switch positions If manual mode is enabled: An undesirable heat transfer from a hot cylinder to a cold collector array can occur. An undesirable heat transfer from a cold collector array to an already hot cylinder can occur the cylinder temperature drops, so that reheating must start, for example. Collector protection is disabled. Cylinder protection is disabled. Collector frost protection is disabled. FM443 function module - Subject to technical modifications. 13

2 Product description 2.3.2 Switch (solar circuit selection) USER INFORMATION If the switch is not in automatic mode, a message to that effect appears on the MEC2 control unit, and the "Module fault" LED on the module illuminates. Position Effect Solar circuit selection is switched off. This setting should only be used for new installations, or when carrying out maintenance or servicing. Automatic changeover to heating solar consumers by the FM443 function module (solar module) is enabled this is the standard setting. When there is appropriate solar yield, only solar consumer "2" (solar circuit 2) is heated. Automatic changeover is disabled. When there is appropriate solar yield, only solar consumer "1" (solar circuit 1) is heated. Automatic changeover is disabled. Tab. 5 Switch positions 14 FM443 function module - Subject to technical modifications.

The FM443 functions 3 3 The FM443 functions The following sections explain how to utilise and set the various functions via the MEC2 programming unit. 3.1 Integration of the FM443 function module into the control unit SERVICE LEVEL Gen. parameters Calling up the service level The relevant service instructions for your Logamatic 4xxx control unit explain in detail how to operate the MEC2 programming unit. The following provides a brief overview of the MEC2 operation. The MEC2 programming unit offers two control levels (level 1 with closed flap and level 2 with open flap) plus one service level (accessible via password). Various main menus are offered at the service level, giving access to sub-menus, where you can change the settings of the control units. Fig. 2 MEC2 programming unit 1 1 Display 2 Rotary selector 3 Function keys 2 3 To reach the service level, press the following key combination (password), until "SERVICE LEVEL Gen. parameters" appears on the display. FM443 function module - Subject to technical modifications. 15

3 The FM443 functions Integrating the FM443 function module at the MEC2 level After you have installed the FM443 function module ( installation instructions "Modules for 4xxx control units") your control unit will detect it automatically when it is switched on. USER INFORMATION If the FM443 function module is not recognised automatically, you will need to manually install it once via the MEC2 programming unit. Manual integration of FM443 function module at the MEC2 level Call up the service level. Turn the rotary selector until "SERVICE LEVEL Module selection" appears on the display. SERVICE LEVEL Module selection Press "Display" to select the main menu "MODULE SELECTION". MODULE SELECTION Slot A Boiler module ZM434 The display shows "MODULE SELECTION Slot A". 16 FM443 function module - Subject to technical modifications.

The FM443 functions 3 Turn the rotary selector to the position (slot) where the FM443 function module is installed. The FM443 function module should be installed in e.g. slot 2. Hold "Display" down (the text on the bottom line begins to flash), and turn the rotary selector until the FM443 function module appears on the display. Release the "Display" key. Press "Back". MODULE SELECTION Slot 2 Solar panel FM443 The FM443 function module (solar panel) is installed in slot 2. Press "Back" three times or close the flap to reach operating level 1. FM443 function module - Subject to technical modifications. 17

3 The FM443 functions 3.2 Changing operating mode You can change the solar control unit operating mode. The operating modes are as follows: Manual ON ("Day mode" key) Manual OFF ("Night mode" key) Automatic operation ("AUT" key) USER INFORMATION Collector protection is ensured with the "Manual ON" operating mode ("Day mode key). USER INFORMATION When the flap on the MEC2 programming unit is closed, it generally indicates the heating circuit to which the MEC2 programming unit is assigned. If the MEC2 programming unit is not assigned to any heating circuit, then the lowest installed heating circuit is always indicated. For further details, please see the technical documentation for your control unit. Open the flap of the MEC2 programming unit. Press and hold down "heating circuit". Turn the rotary selector until "Heating circuit selection solar" appears on the display. Release the "Heating circuit" key. 18 FM443 function module - Subject to technical modifications.

The FM443 functions 3 Different operating modes Press manual ON ("day mode" key) to set the solar control unit to "permanent on". Press the "AUT" key to set the solar control to automatic. Press manual OFF ("night mode" key) to switch off the solar control unit. Operating mode Input range Automatic OFF ON Factory setting Automatic Manual ON No control functions are involved when the circuit is running in this mode; however, the solar thermal system will cut out if either the collector array or the cylinder(s) exceed(s) the maximum permissible temperatures. In Const. operation: An undesirable heat transfer from a hot cylinder to a cold collector array can occur. An undesirable heat transfer from a cold collector array to an already hot cylinder can occur the cylinder temperature drops, so that reheating must start, for example. FM443 function module - Subject to technical modifications. 19

3 The FM443 functions 3.3 Solar consumer "1" solar circuit 1 You can link an initial consumer (e.g. cylinder) into the control unit via the FM443 function module. USER INFORMATION Only connect one DHW cylinder for DHW heating as solar consumer "1". 3.3.1 Setting the maximum cylinder temperature Call up the service level. Turn the rotary selector until "SERVICE LEVEL Solar" appears on the display. Press "Display" to select the main menu "SOLAR DATA". Turn rotary selector until "SOLAR DATA Max. temperature Cylinder 1" appears on the display. SOLAR DATA Max. temperature Cylinder 1 60 C Hold down "Display" and turn the rotary selector. You can now set the maximum cylinder temperature. Input range Factory setting Max. temperature Cylinder 1 30 C 90 C 60 C 20 FM443 function module - Subject to technical modifications.

The FM443 functions 3 3.3.2 Setting cylinder temperature setback (optimisation function) Call up the service level. Turn the rotary selector until "SERVICE LEVEL Solar" appears on the display. Press "Display" to select the main menu "SOLAR". Turn rotary selector until "SOLAR DATA Solar cylinder 1 setback to" appears on the display. SOLAR DATA Solar cylinder 1 setback to none Hold down "Display" and turn the rotary selector. You can now adjust the cylinder temperature setback. USER INFORMATION The FM443 function module offers an optimisation function for increasing the solar yield. Subject to the solar yield, the reheat temperature can be reduced to the value set here. Set back cylinder 1 to Input range none 30 C 54 C Factory setting none FM443 function module - Subject to technical modifications. 21

3 The FM443 functions 3.4 Buffer integration With this parameter you determine how the buffer cylinder if installed is to be integrated into the system. The buffer can be linked up as follows: None: in other words none is installed (factory setting), Buffer bypass, Dual-purpose (cylinder) SP1, Dual-purpose (cylinder) SP2. USER INFORMATION If a buffer bypass circuit is installed in the system, enable the "bypass" function using the MEC2 programming unit. If you have enabled this function, enter the corresponding start and stop differentials. 3.4.1 Selecting the buffer integration Call up the service level. Turn the rotary selector until "SERVICE LEVEL Solar" appears on the display. Press "Display" to select the main menu "Solar". 22 FM443 function module - Subject to technical modifications.

The FM443 functions 3 Turn the rotary selector until "SOLAR DATA Buffer Integration none" appears on the display. SOLAR DATA Buffer Integration none Hold down "Display" and turn the rotary selector. Now you can select the form of buffer cylinder integration. Buffer integration Input range none buffer bypass dual-purpose SP1 dual-purpose SP2 Factory setting none No buffer integration If you set the integration to "none", then the module assumes that no buffer cylinder is to be taken into consideration. Buffer bypass If "Buffer bypass" is selected as the method of integration, then the module assumes that the solar thermal system is also to be used for central heating backup, and that the buffer cylinder is to be integrated as a return temperature raising facility for a standard heat source. Buffer integration as dual-purpose cylinder If "Dual-purpose SP1/SP 2" is selected as the method of integration, the module assumes that not only the solar thermal system transfers its energy to the buffer cylinder but also the standard heat source, leaving the system to be wholly or partially supplied by the buffer cylinder. For this you can differentiate between cylinder 1 or cylinder 2 acting as the dual-purpose cylinder. FM443 function module - Subject to technical modifications. 23

3 The FM443 functions 3.4.2 Setting the buffer and bypass throughput The buffer bypass control unit regulates the changeover of the three-way valve SPB subject to the temperature differential between the buffer cylinder (FPB-FP sensor) and the system return (sensor FPB-FR). Buffer receives throughput: Volume flow through the buffer cylinder Bypass receives throughput: Volume flow passes the buffer by (straight into the boiler return or the low loss header) The volume flow will be routed through the buffer cylinder when the temperature inside the buffer cylinder is greater than the temperature in the system return by the level specified under "Buffer receives throughput from ΔT". The throughput will be routed through the buffer cylinder as long as the temperature differential between the buffer cylinder and the system return does not fall below the value selected for "Bypass receives throughput from ΔT". If the actual differential falls below this selected value, then the bypass will be changed over for as long as the changeover threshold "Buffer receives throughput from ΔT" is not reached again. USER INFORMATION The changeover threshold for the bypass receiving the throughput must always be smaller than the changeover threshold for the buffer receiving the throughput. At the menu level "SOLAR DATA" you can select the changeover threshold for buffer and bypass receiving the throughput, subject to the buffer bypass circuit having been enabled. 24 FM443 function module - Subject to technical modifications.

The FM443 functions 3 Turn rotary selector one click clockwise until "SOLAR DATA Flow to th/store from ΔT" appears on the display. SOLAR DATA Flow to th/store from ΔT 10K Hold down "Display" and turn the rotary selector. Now you can select the changeover temperature differential for the buffer receives throughput. Input range Factory setting Buffer receives throughput from ΔT 7K 20K 10K Turn rotary selector one click clockwise until "SOLAR DATA Flow to bypass from ΔT" appears on the display. SOLAR DATA Flow to bypass from ΔT 5K Hold down "Display" and turn the rotary selector. Now you can select the changeover temperature differential for the bypass receives throughput. Input range Factory setting Bypass receives throughput from ΔT 5K 15K 5K FM443 function module - Subject to technical modifications. 25

3 The FM443 functions 3.5 Solar circuit heat meter If there is a heat meter set installed in the solar circuit, you can display its values on the MEC2 programming unit display. This differentiates between the heat yield for the first and second solar consumer. The heat volume in the second solar consumer is calculated using the pump runtime. USER INFORMATION You can only use this function in conjunction with the heat meter set. This set is available from Buderus as an accessory. USER INFORMATION Ensure that you connect the WMZ sensor correctly ( Tab. 2, page 10). Enable the "heat meter" function. If you have enabled this function ("yes"), you must set the corresponding glycol content in the solar circuit. 26 FM443 function module - Subject to technical modifications.

The FM443 functions 3 3.5.1 Enabling heat metering Call up the service level. Turn the rotary selector until "SERVICE LEVEL Solar" appears on the display. Press "Display" to select the main menu "SOLAR DATA". Turn the rotary selector until "SOLAR DATA Heat meter" appears on the display. SOLAR DATA Heat meter yes Hold down "Display" and turn the rotary selector. You can now enable heat volume recording. Heat meter Input range yes no Factory setting no FM443 function module - Subject to technical modifications. 27

3 The FM443 functions 3.5.2 Setting glycol content If you have enabled heat metering, you must set the glycol content in the "SOLAR DATA" menu level. Turn rotary selector one click clockwise until "SOLAR DATA Glycol content" appears on the display. SOLAR DATA Glycol content 50% Hold down "Display" and turn the rotary selector. You can now set the glycol content. USER INFORMATION If a solar circuit uses glycol water, you must test the glycol content with a hydrometer. The solar yield is calculated using the specific heat capacity of the medium in the solar circuit and the volume flow. Input range Glycol content 0% 30 % 40 % 50 % Factory setting 50 % 28 FM443 function module - Subject to technical modifications.

The FM443 functions 3 3.5.3 Enabling the statistic function Call up the service level. Turn the rotary selector until "SERVICE LEVEL Gen. parameters" appears on the display. Press "Display" to call up the main menu "GENERAL PARAM.". Turn the rotary selector until "GENERAL PARAM. Heat yield no display" appears on the display. GENERAL PARAM. Heat yield no display Hold down "Display" and turn the rotary selector. Now you can select the display for solar data for the statistic function. Heat yield Input range none burner* solar * only for single stage floorstanding boiler without EMS Factory setting none FM443 function module - Subject to technical modifications. 29

3 The FM443 functions 3.6 Pump function secondary circuit pump The solar module is equipped with a pump output that, subject to application, can be assigned to different functions. The pump can be integrated with the following functions: None: in other words none is installed (factory setting), Sec. cylinder 2 (secondary circuit pump cylinder 2), Transfer (heating the pre-heat stage), Transfer pump (cylinder in series circuit). 3.6.1 Selecting the buffer integration Call up the service level. Turn the rotary selector until "SERVICE LEVEL Solar" appears on the display. Press "Display" to call up the main menu "Solar". Turn the rotary selector until "SOLAR DATA Pump function none" appears on the display. SOLAR DATA Pump function none Hold down "Display" and turn the rotary selector. Now you can select the pump function. 30 FM443 function module - Subject to technical modifications.

The FM443 functions 3 Pump function Input range none Sec. cylinder 2 Transfer Transfer pump Factory setting none No pump function If you select "none" as the pump function, the module assumes that no pump is connected. Consequently, this output will not be controlled by the FM443 function module. Sec. cylinder 2 If you select "Sec. cylinder 2" as the pump function, the pump connected there will operate as a secondary circuit pump for heating the second solar consumer, i.e. the second consumer is operated via a heat exchanger. FM443 function module - Subject to technical modifications. 31

3 The FM443 functions Transfer If you select "transfer" as the pump function, the pump connected there will heat the solar pre-heat stage, if required, once per day to 60 C or to the termal disinfection temperature in accordance with the DVGW Code of Practice 552, to prevent the growth of legionella bacteria. FB PS2 FSS Fig. 3 Transfer in a circuit with a solar cylinder 32 FM443 function module - Subject to technical modifications.

The FM443 functions 3 Transfer pump If you select "Transfer pump" as the pump function, the pump connected there is designed to transfer the energy between the solar cylinder and the cylinder heated by the boiler in a cylinder in series circuit. In other words, as soon as the solar cylinder is hotter than the cylinder heated by the boiler, pump PS2 starts and the energy is transferred from one to the other. In addition this pump is used, if required, to heat the solar cylinder, i.e. the solar pre-heat stage, once per day to 60 C or to the termal disinfection temperature to prevent the growth of legionella bacteria, in accordance with the DVGW Code of Practice 552. Fig. 4 Transfer for cylinder in series circuit FM443 function module - Subject to technical modifications. 33

3 The FM443 functions 3.6.2 Select transfer pump start Transfer starts when the FSS solar sensor captures a temperature higher by the value selected here than that captured at the FB DHW sensor. Call up the service level. Turn the rotary selector until "SERVICE LEVEL Solar" appears on the display. Press "Display" to select the main menu "Solar". Turn the rotary selector until "SOLAR DATA Transfer pump Start 10K" appears on the display. SOLAR DATA Transfer pump Start 10K Hold down "Display" and turn the rotary selector. Now you can select the start temperature differential for the transfer pump. Input range Factory setting Transfer pump Start 2 K 10 K 5 K 34 FM443 function module - Subject to technical modifications.

The FM443 functions 3 3.6.3 Select transfer pump stop Transfer stops when the temperature captured by the FSS solar sensor comes close to the temperature captured by the FB DHW sensor. Call up the service level. Turn the rotary selector until "SERVICE LEVEL Solar" appears on the display. Press "Display" to select the main menu "Solar". Turn the rotary selector until "SOLAR DATA Transfer pump Stop 5K" appears on the display. SOLAR DATA Transfer pump Stop 5K Hold down "Display" and turn the rotary selector. Now you can select the start temperature differential for the transfer pump. Input range Factory setting Transfer pump Stop 2K 10 K 5K FM443 function module - Subject to technical modifications. 35

3 The FM443 functions 3.7 Heating up the pre-heat stage There in an option, subject to the pump function "Transfer" or "Transfer pump" being selected, to heat up the solar pre-heat stage, i.e. the lower half of a dual-mode cylinder or the solar cylinder in a cylinder in series circuit via the boiler, as part of the termal disinfection and or the daily heat-up to 60 C to prevent the growth of legionella bacteria. The following settings are possible: OFF: In other words, no heat-up of the pre-heat stage (factory setting) Termal disinfection: The pre-heat stage will only be heated up during termal disinfection. Heat-up: The pre-heat stage is only heated as part of the daily heat-up to 60 C. Termal disinfection + heat-up: The pre-heat stage is heated up as part of termal disinfection and during the daily heat-up to 60 C. 3.7.1 Solar cylinder 1 heating Call up the service level. Turn the rotary selector until "SERVICE LEVEL Solar" appears on the display. Press "Display" to select the main menu "SOLAR". 36 FM443 function module - Subject to technical modifications.

The FM443 functions 3 Turn rotary selector until "SOLAR DATA Solar cylinder 1 Heating OFF" appears on the display. SOLAR DATA Solar cylinder 1 Heating Off Hold down "Display" and turn the rotary selector. Now you can adjust the heat-up of the pre-heat stage. USER INFORMATION The settings for daily heat-up and termal disinfection are made at the DHW function ( Control unit service instructions). Solar cylinder 1 Heating Input range OFF Therm. disinfect Heat-up Disinfect+heat-up Factory setting none FM443 function module - Subject to technical modifications. 37

3 The FM443 functions 3.8 Solar consumer "2" solar circuit 2 If you want to connect a second solar consumer (e.g. swimming pool or buffer cylinder) via the FM443 function module to the control unit, enable the function "consumer 2". The second consumer can be heated using a diverter valve or a separate pump. 3.8.1 Enabling second solar consumer Call up the service level. Turn the rotary selector until "SERVICE LEVEL Solar" appears on the display. Press "Display" to select the main menu "SOLAR DATA". Turn the rotary selector until "SOLAR DATA Consumer 2" appears on the display. SOLAR DATA Consumer 2 none Hold down "Display" and turn the rotary selector. You can now enable the second consumer. Consumer 2 Input range None Three-way valve Sep. pump Factory setting none 38 FM443 function module - Subject to technical modifications.

The FM443 functions 3 3.8.2 Setting changeover options If you have enabled solar consumer 2, set the changeover in the "SOLAR DATA" menu level. Turn the rotary selector until "SOLAR DATA Change over" appears on the display. SOLAR DATA Change over automatic Hold down "Display" and turn the rotary selector. You can now set the various changeover options. Change over Input range automatic always cylinder 1 always cylinder 2 Factory setting automatic FM443 function module - Subject to technical modifications. 39

3 The FM443 functions 3.8.3 Setting the maximum cylinder temperature If you have enabled solar consumer 2, set the maximum cylinder temperature in the "SOLAR DATA" menu level. Turn rotary selector until "SOLAR DATA Max. temperature Cylinder 2" appears on the display. SOLAR DATA Max. temperature Cylinder 2 60 C Hold down "Display" and turn the rotary selector. You can now set the maximum cylinder temperature. Input range Factory setting Max. temperature Cylinder 2 20 C 90 C 60 C 40 FM443 function module - Subject to technical modifications.

Relay test 4 4 Relay test With the "Relay test" menu, you can check whether the external components (e.g. pumps) are correctly connected. SYSTEM DAMAGE CAUTION! Proper system functioning is not guaranteed while a relay test is being carried out. The control unit disables all functions. Leave this function at the end of the relay test to prevent system damage. Relay test If you have selected the "Relay test solar" function, you can individually switch on/off the pumps connected to the FM443 function module. If the "Relay test" function is enabled: An undesirable heat transfer from a hot cylinder to a cold collector array can occur. An undesirable heat transfer from a cold collector array to an already hot cylinder can occur the cylinder temperature drops, so that reheating must start, for example. Collector protection is disabled. Cylinder protection is disabled. Collector frost protection is disabled. FM443 function module - Subject to technical modifications. 41

4 Relay test Call up the service level. Turn the rotary selector until "SERVICE LEVEL Relay test" appears on the display. Press "Display" to select the main menu "Relay test". RELAY TEST "RELAY TEST Boiler" appears on the display. Boiler Turn the rotary selector until "RELAY TEST Solar" appears on the display. Press "Display" to select the sub-menu "RELAY TEST Solar". You can test the following relays to see if they function properly (on/off): Diverter valve Bypass Pri. pump SP1 Pri. pump SP2 Sec. pump SP2 42 FM443 function module - Subject to technical modifications.

Fault log 5 5 Fault log Using the "Fault log" menu, you can display the last four fault messages of your heating controller. Call up the service level. Turn the rotary selector until "SERVICE LEVEL Fault log" appears on the display. SERVICE LEVEL Fault log Press "Display" to select the main menu "Fault log". Fault 1 Sol.byp.RTsensor from 08:30 06.11 to 11:08 06.11 The following faults can be displayed: Collector sensor Bypass buffer sensor Bypass return sensor Heat meter flow sensor Heat meter return sensor Sensor cylinder 1, bottom Sensor cylinder 2, bottom Flow metering Setting hysteresis FM443 function module - Subject to technical modifications. 43

6 Fault 6 Fault USER INFORMATION All the faults that can arise in the interaction between the FM443 function module, the solar consumers and a heat meter are listed in the "Fault" column. The terms in the "Fault" column show the messages as they appear on the MEC2 programming unit display. Fault Buffer sensor bypass Effect on control characteristics Bypass output not being controlled. Possible causes of the fault Buffer sensor faulty. Buffer sensor not connected or incorrectly connected. FM443 or control unit faulty. Remedy Check sensor connection to FM443 function module (FPB-FP). Check sensor on bypass for breaks or incorrect position. Return sensor bypass Bypass output not being controlled. Return sensor faulty. Return sensor not connected or incorrectly connected. FM443 or control unit faulty. Check, for example, the fuse. Check sensor connection to FM443 function module (FPB-FR). Check sensor on bypass for breaks or incorrect position. Check, for example, the fuse. 44 FM443 function module - Subject to technical modifications.

Fault 6 Fault Heat meter flow sensor Heat meter return sensor Collector sensor Sensor cylinder 1, bottom Effect on control characteristics Heat yield is not captured. Heat yield is not captured. Cylinders 1 and 2 are not being heated with solar energy. Cylinder 1 not being heated with solar energy. Possible causes of the fault Flow sensor faulty. Flow sensor not connected or incorrectly connected. FM443 or control unit faulty. Return sensor faulty. Return sensor not connected or incorrectly connected. FM443 or control unit faulty. Collector sensor not connected or incorrectly connected. FM443 or control unit faulty. Cylinder 1 sensor faulty. Remedy Check sensor connection to FM443 function module (WMZ-FV). Check sensor on solar thermal system flow for breaks or incorrect position. Check, for example, the fuse. Check sensor connection to FM443 function module (WMZ-FR). Check sensor on solar thermal system return for breaks or incorrect position. Check, for example, the fuse. Collector sensor faulty. Check collector sensor for breaks or incorrect position. Cylinder 1 sensor not connected or incorrectly connected. FM443 or control unit faulty. Check, for example, the fuse. Check the sensor on cylinder 1 for breaks or incorrect position. Check, for example, the fuse. FM443 function module - Subject to technical modifications. 45

6 Fault Fault Sensor cylinder 2, bottom Effect on control characteristics Cylinder 2 not being heated with solar energy. Possible causes of the fault Cylinder 2 sensor faulty. Cylinder 2 sensor not connected or incorrectly connected. Remedy Check the sensor on cylinder 2 for breaks or incorrect position. Check, for example, the fuse. Hysteresis setting Flow metering FM443 or control unit faulty. FM443 function The values set by the module is switched off. user are not coherent. Heat yield is not captured. The start threshold is lower than the stop threshold, either for cylinder 1, 2 or the bypass. Flow meter faulty or incorrectly connected. FM443 function module faulty. Hydraulics are faulty. Check the settings of the FM443 function module with the MEC2 programming unit. Is the flow meter correctly connected to the FM443 function module? Check that the solar module is functioning correctly. Replace the FM443 function module if required. 46 FM443 function module - Subject to technical modifications.

Monitor data 7 7 Monitor data Using the main menu "Monitor", you can scan current values (monitor data) from the solar control unit. Call up the service level. Turn the rotary selector until "SERVICE LEVEL Monitor" appears on the display. Press "Display" to select the main menu "MONITOR". MONITOR "MONITOR Boiler" appears on the display. Boiler Turn the rotary selector until "MONITOR Solar" appears on the display. Press "Display" to select the sub-menu "MONITOR solar". Once inside the sub-menu, you can scan the current values and system conditions. FM443 function module - Subject to technical modifications. 47

7 Monitor data 7.1 Solar consumer "1" solar circuit 1 7.1.1 Collector temperature operating mode MONITOR SOLAR Collector 110 C Cylinder 1 blocked The display shows the current collector temperature and the operating mode of cylinder 1. Cylinder 1 Display options Blocked Idle Low flow High flow Manual ON Blocked Cylinder 1 is not being heated because: the collector temperature is too high or the cylinder temperature is too high or cylinder 1 is switched off or another cylinder is currently being heated or there is a fault in the FM443 function module. Idle The solar energy produced by the collector is insufficient to heat cylinder 1. LOW FLOW Cylinder 1 is heated with a large temperature differential (low flow rate). HIGH FLOW Cylinder 1 is heated with a small temperature differential (high flow rate). 48 FM443 function module - Subject to technical modifications.

Monitor data 7 Manual on The control unit is in "manual ON" operating mode. This means that solar circuit pump 1 operates at 100 %. All control functions on the FM443 function module are disabled, except the maximum collector temperature control. 7.1.2 Temperatures in cylinder 1, status of solar circuit pump 1 MONITOR SOLAR SP1 centre 30 C SP1 bottom 15 C Pump SP1 50% The display shows the current temperatures in cylinder 1 and the status of solar circuit pump 1. "SP1 centre" = DHW heating temperature "SP1 bottom" = Solar cylinder temperature, bottom "Pump SP1" = Modulation factor of solar circuit pump 1 7.1.3 Solar yield MONITOR SOLAR Solar yield 1 20000 kwh Current 450 W The display shows the total and current solar yield of solar circuit 1. 7.2 Buffer bypass circuit MONITOR SOLAR Bypass Off Buffer 60 C Return flow 30 C The display shows the status of the three-way valve (buffer bypass circuit) as well as the temperatures of the buffer cylinder and heating return. Bypass Display options Off Direct Cylinder FM443 function module - Subject to technical modifications. 49

7 Monitor data Off The buffer bypass circuit is switched off or was not enabled by the MEC2 programming unit. The corresponding outputs are not being controlled by the solar control unit. In this case, the diverter valve setting depends on the type of valve used. Check that the diverter valve was correctly installed. Direct The heating system return temperature is higher than the temperature in the lower section of the buffer or combi cylinder. The heating return is fed directly into the boiler. The diverter valve is in the "Bypass" setting. Cylinder The heating system return temperature is lower than the temperature in the buffer cylinder or the lower section of the combi cylinder. The heating return is fed through the diverter valve for preheating via the buffer or combi cylinder. 7.3 Solar circuit heat meter MONITOR SOLAR Volume 900 l/h Flow 90 C Return flow 30 C The display shows the current flow captured by the flow meter (heat meter set) as well as the corresponding flow and return temperatures on the solar circuit. 50 FM443 function module - Subject to technical modifications.

Monitor data 7 7.4 Solar consumer "2" solar circuit 2 7.4.1 Collector temperature, operating mode MONITOR SOLAR Collector 110 C Cylinder 2 blocked The display shows the current collector temperature and the operating mode of cylinder 2. Cylinder 2 Display options Blocked Idle High flow Changeover check Manual ON Blocked Cylinder 2 is not being heated because: the collector temperature is too high or the cylinder temperature is too high or cylinder 2 is switched off or another cylinder is currently being heated or there is a fault in the FM443 function module. Idle The solar energy produced by the collector is insufficient to heat cylinder 2. HIGH FLOW Cylinder 1 is heated with a small temperature differential (high flow rate). FM443 function module - Subject to technical modifications. 51

7 Monitor data Changeover check The conditions for a "changeover check" are: solar consumer "2" is being heated and solar consumer "1" has been shut down (the required temperature differential for heating the cylinder is not present). Once these conditions have been met, the solar control unit checks whether heating of solar consumer "1" is possible (this consumer has priority). This check repeats at regular intervals (factory setting = 30 minutes), until solar consumer "1" can be heated again. Manual on The control system is in "manual ON" operating mode. This means that solar circuit 2 is being controlled. All control functions on the FM443 function module are disabled, except the maximum collector temperature control. 52 FM443 function module - Subject to technical modifications.

Monitor data 7 7.4.2 Temperatures in cylinder 2, status of solar circuit pump 2 or diverter valve and secondary pump of solar heating circuit 2 MONITOR SOLAR SP2 bottom 30 C 3-way valve Off Sec. pump SP2 Off As an example, the display shows the current temperature in cylinder 2 and the operating modes of the pumps and valves. "SP2 bottom" = Temperature solar cylinder 2, bottom "3-way valve" = Diverter valve status "SecPump SP2" = Secondary solar circuit pump 2 Three-way valve Pri. pump SP2 Sec. pump SP2 Display options SP1 (cylinder 1) SP2 (cylinder 2) OFF on/off on/off 7.4.3 Solar yield MONITOR SOLAR Solar yield 2 20000 kwh Current 450 W The display shows the total and current solar yield of solar circuit 2. FM443 function module - Subject to technical modifications. 53

8 Sensor curve 8 Sensor curve Isolate the system before taking any readings. Troubleshooting Remove the sensor terminals. Check the resistance at the sensor lead ends using an ohmmeter. Check the sensor temperature with a thermometer. Using the diagram you can check whether temperature and resistance correlate. Collector sensor (FSK) curve Fig. 5 Collector sensor (FSK) curve 54 FM443 function module - Subject to technical modifications.

Index 9 9 Index A Automatic mode.......... 18, 19 B Blocked............... 48, 51 Buffer bypass circuit........ 9, 10 Buffer receives throughput..... 24, 25 Bypass cylinder............. 50 Bypass direct.............. 50 Bypass off................ 50 Bypass receives throughput.... 24, 25 C Changeover check........... 52 Changeover options.......... 39 Collector temperature........ 48, 51 Cylinder in series circuit...... 30, 33 Cylinder temperature setback..... 21 D Disposal.................. 6 Domestic hot water heating....... 20 F FP sensor.............. 10, 44 FPB sensor............... 10 FR sensor.............. 10, 44 FV sensor................ 10 G Glycol content.............. 28 H Heat metering enabling........ 27 HIGH FLOW............ 48, 51 I Idle................. 48, 53 Integration FM443 function module....... 15, 16 L LOW FLOW............... 48 M Manual OFF............. 18, 19 Manual ON.......... 18, 19, 49 Maximum cylinder temperature..... 20 Maximum cylinder temperature setting 40 Monitor data solar........... 47 O Operating mode changing...... 18 P Pri. pump SP2.............. 53 R Relay test................ 42 S Sec. pump SP2............. 53 Sensor curve.............. 54 Service level.............. 15 Solar circuit heat meter......... 26 Solar consumer "1"........... 20 Solar consumer "2"........... 38 Solar module arrangement....... 11 Solar yield.............. 49, 53 SP1................... 53 SP2................... 53 Switch.................. 12 V Version..................7 W WMZ sensor.............. 45 FM443 function module - Subject to technical modifications. 55

Buderus Cotswold Way, Warndon, Worcester WR4 9SW Customer service: 0870 421 5933 Technical support: 0870 421 5944 Fax: 01905 753130 www.buderus.co.uk C & F Quadrant Ltd. Unit L40 Cherry Orchard Industrial Estate Cherry Orchard, Dublin 10 Tel.: 01.6305700 Fax.: 01.6305706 / 01.6305715 www.cfquadrant.ie E-mail: sales@cfquadrant.ie In the UK and IE, Buderus is a brand name of Bosch Thermotechnology Ltd. Bosch Thermotechnik GmbH Sophienstrasse 30-32 D-35576 Wetzlar www.buderus.de info@buderus.de