The following translation is for informative purposes only. The legally binding text is found in the Boverket s Code of Statutes (www.boverket.se).

Similar documents
The Swedish National Board of Housing, Building and Planning s general recommendations on the analytical design of a building s fire protection, BBRAD

FIRE DEPARTMENT - RULES FOR FIRE PROTECTION IN AUSTRIA

Short Term Accommodations Fire Code Requirements

Fire damper DESIGN GENERAL FIRE CELL DIVISION DISTRIBUTION OF RESPONSIBILITIES FIRE PROTECTION DOCUMENTATION HAGAB FIRE DAMPER DESIGN

Element C3.5 Means of Escape

ADMINISTRATIVE ORDER # CERTIFICATES OF USE AND OCCUPANCY FOR EXISTING BUILDINGS

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

Retain. Retain. Retain. Board Advisory. Board Advisory. Retain. Disposition. (Statute, Rule, FBC, Industry)

CHAPTER 7 ALTERATIONS LEVEL

5123: information. The graphic plan shall include, but may not be limited to: (a) A primary and secondary means of exit from each floor;

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

Florida Building Code 2010

Fire Safety Audit: Part B - Questionnaire (Questionnaire Devised By Mr.R.R.Nair) Yes No x

Sprinkler Permit Applications

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

Agency for Health Care Administration

Fire protection documentation. CFPA-E Guideline No 13:2015 F

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

ICC CODE CORNER 2015 International Fire Code

Chapter Nursing Homes

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #2

CHILD CARE CENTER INSPECTION CHECKLIST 06C

Environmental Planning and Assessment Amendment (Smoke Alarms) Regulation 2006

Agency for Health Care Administration

Life Safety - Means of Egress/Exits NFPA 101

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101):

[NOTE: Proposed additions to existing code language are highlighted in yellow.]

First Published in the Wichita Eagle on DELINEATED 10/02/2010 ORDINANCE NO.

Emergency Planning for Institutional Facilities

INITIAL FIRE SAFETY ASSESSMENT

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

Approved Document for New Zealand Building Code Warning Systems Clause F7 Third Edition

Residential Care Facilities Requirements

Agency for Health Care Administration

Family Foster Home Fire Safety Evaluation Checklist Instructions

Short-Term & Accessory Short-Term Rental Safety Certification

Fire Management Guide

Item Referenced and Amendments Building 1 Building 2 Analysis, Review and Remarks. Page 1 of 15

Report on First Revisions with Statement June 2014 NFPA 101

New Fire Safety Order

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

Amend Base Code. Amend Base Code. Amend Base Code. Disposition. (Statute, Rule, FBC, Industry) Y/N

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

Fire Safety Risk Assessment for Treowen, Wonastow, Monmouth, NP25 4DL

Design Guidelines Fire Safety in New and Refurbished Buildings

SECTION 915 CARBON MONOXIDE DETECTION

97 FCV 006 Page 2 of 16 EXPLANATORY MATERIAL

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

INITIAL FIRE SAFETY ASSESSMENT

Fire and Life Safety GUIDE

SPECIAL AMUSEMENT OCCUPANCIES HAUNTED HOUSE, SCARE HOUSE OR MAZE

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS

SAF-BCF SECOND REVISIONS WITH STATEMENTS

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

FIRE SAFETY PLAN ADMINISTERED BY: DEPARTMENT OF ENVIRONMENTAL HEALTH AND SAFETY

p. vi, References p. v, Contents p. 7, References pp. 7-8, References p. 5, Contents p. 7, References p. 9, Definitions p. 13, 1.2.

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Washoe County Department of Social Services

Fire Risk Assessment 2017

ORDINANCE NO NOW, THEREFORE, BE IT ENACTED BY THE CITY COUNCIL OF THE CITY OF FAIRBANKS, ALASKA, as follows:

EMERGENCY EVACUATION PLAN

Iowa (2) Delete section and insert in lieu thereof the following new section:

SELF PRESERVATION SOCIETY By Jim Creak

MULTI-LEVEL & COVERED BOOTH CONDITIONS

2018 NICET Code Transition Changes

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

Agency for Health Care Administration

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

Fire precautions in dwellings

INITIAL FIRE SAFETY ASSESSMENT

THE MAURITIUS FIRE AND RESCUE SERVICE ACT. Regulations made by the Minister under sections 18, 19 and 27 of the Mauritius Fire and Rescue Service Act

Large Family Daycare Guideline

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

Compliance Document for New Zealand Building Code Clause F7 Warning Systems Third edition

Renovation Program. Renovation Program GENERAL

APPLICATION FOR Large Family Day Care Permit

During the holiday season, electrical fires are one of the leading causes of damage to residential structures. Specific causes included:

Dear Customer. Section Old F8 January 2017 Amendment 4. Replace with new title page and document history pages 1 2B

Agency for Health Care Administration

Tudor House, Kingsway Business Park Oldfield Road, Hampton, Middlesex, TW12 2HD Phone: +44 (0) Website: EQUALITY ACT 2010

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

DEPARTMENT OF CONSUMER AND INDUSTRY SERVICES DIVISION OF ADULT FOSTER CARE LICENSING ADULT FOSTER CARE FACILITIES

INITIAL FIRE ASSESSMENT REPORT (FAR)

BCAC Egress Work Group

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

Building Standards Advisory Promoting construction of safe, healthy, habitable buildings

Chapter BUILDING CODE*

COMMISSIONING OF LIFE SAFETY AND FIRE PROTECTION SYSTEMS: WHAT, WHERE AND HOW?

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

New Facilities. Minimum Requirements

Residential Based Care Facility Guidelines

Transcription:

The Swedish National Board of Housing, Building and Planning s mandatory provisions and general recommendations for temporary accommodation facilities, ATA BFS 2016:5 The following translation is for informative purposes only. The legally binding text is found in the Boverket s Code of Statutes (www.boverket.se). Chapter 1. General Section 1 This statute contains mandatory provisions and general recommendations to Chapter 1, Section 3 b and Chapter 3, Section 28 of the Planning and Building Ordinance (2011: 338), PBO, about adjustments and deviations from the requirements of the Planning and Building Act (2010: 900), PBA, PBO and Boverket s Building Regulations mandatory provisions and general recommendations (2011: 26), BBR. The general recommendations contain general guidance on the application of the above mentioned provisions. The general recommendations are preceded by the words and are printed using smaller, indented text. The statute contains mandatory provisions and general recommendations on adjustments and deviations from the requirements on new construction, reconstruction and other alterations to buildings for temporary accommodation facilities. Adjustments and deviations pursuant to this statute applies in addition to the rules on alteration and relocation of buildings Unless otherwise stated in this statute, other adjustments and deviations are allowed according to Chapter 3, Section 28, PBO, with respect to the nature, extent and duration of the measure. Limited time refers to a few years, no more than the period for which it is possible to get a temporary building permit, i.e. 10 years. The nature of the measure refers to both the occupancy type and the building type. The extent of the measure refers to the size of the occupancy, based on the number of people present in the building and the size of the building. The duration of the measure refers to the time a building is intended to be used as a temporary accommodation facility. Adjustments and deviations can be made to a larger extent if the nature of the measure is of a simpler nature, the extent is small and the duration is short. If the measure in nature, extent and duration is more similar to a permanent accommodation, less adjustments and deviations should be made. If other adjustments and deviations than those specified in this statute are made from the requirement of safety in case of fire, verification should be performed in the manner shown in the Swedish National Board of Housing, Building and Planning s general recommendations (2011:27) on analytical design of a building s fire protection. Section 2 The following definitions are used in this statute kitchen for personal use refers to kitchen, pantry or similar where the residents have the possibility to cook, bedroom refers to rooms intended for the main daily rest. Konsoliderad version (fulltext) 1 (7)

general recommendations for temporary accommodation facilities, ATA Bedroom corresponds to room for sleep and rest in Sections 1, 3, 6 and 7 BBR and guest room, hotel room or suite in occupancy class 4 and residential room in occupancy class 3B in Section 5 BBR. Chapter 2. Safety in case of fire General Mandatory provisions and general recommendations to Section 5:12 BBR Section 1 The adjustments and deviations made in relation to the mandatory provisions and general recommendations regarding safety in case of fire in Section 5 BBR shall be documented in the fire protection documentation. Adjustments and deviations should be summarized in a separate section of the documentation. to Section 5:21 BBR The fire protection should be designed as temporary housing in occupancy class 4 or shared lodging in occupancy class 3B. The fire protection rules for occupancy class 3A or 5B may be used if appropriate with regard to the nature, extent and duration of the measure. to Section 5:2513 BBR Design of interconnected smoke alarm devices can be verified pursuant to SS-EN 14604:2005/AC:2008. to Section 5:53 BBR Rooms with very low fire load that connect to an escape route can be part of the escape route fire compartment. Examples of rooms with very low fire load can be single toilets. Mandatory provisions to Section 5:7 BBR Section 2 Adjustments and deviations from the requirements for the possibility of rescue responses in Section 5:7 BBR are not allowed. Occupancy class 4 to Section 5:22 BBR Buildings in occupancy class 4 with two storeys can be constructed in building class Br2. Mandatory provisions and general recommendations to Section 5:31 BBR Section 3 If bedrooms in occupancy class 4 are intended to be used by more than 10 persons, additional fire protection measures shall be taken. 2 (7)

general recommen-dations for temporary accommodation facilities, ATA Examples of additional fire protection measures can be emergency lighting and exit signs inside the bedroom and access to two separate escape routes that lead directly to a secure location. The more people that are intended to use the bedroom, the more additional measures should be taken. Bedrooms intended for more than 10 persons should be easy to overview. Hazards such as kitchen for personal use should not be present. Mandatory provisions and general recommendations to Section 5:323 BBR Section 4 One of the escape routes from bedrooms in occupancy class 4 may be replaced with access to a window if the window sill is no more than 2.0 meters above the ground level outside and the evacuation can take place in a satisfactory manner, the window is intended for evacuation only from the bedroom it is located in, the room is not intended for use by people with limited mobility or orientation capacity, and the window is provided with an exit sign. Each window should provide an escape route for a maximum of 10 people. The window should also meet the general recommendations to Section 5:323, first paragraph BBR. Exit signs in bedrooms do not have to be illuminated or backlit to Section 5:334 and 5:335 BBR In tents, caravans and similar buildings in occupancy class 4, escape routes can have a lower height and width than those recommended in Section 5:334 BBR. Original doors and opening devices for these buildings may normally be used as an escape route. For a maximum of 10 people, a zipper and similar opening devices in tents can be accepted if there are at least two exits. to Section 5:354 BBR In buildings with up to two storeys in occupancy class 4 intended for a maximum of 20 people, devices for early detection and warning in case of fire may consist of interconnected smoke alarm devices. For buildings only in ground level that have direct access to the outside from every bedroom, the requirement for early detection and warning in case of fire can be met with interconnected smoke alarm devices without being supplemented with manually activated evacuation alarms. The interconnected smoke alarm devices should be installed in all bedrooms, in common areas, and near kitchen areas. to Section 5:544 BBR Separating structures around bedrooms in buildings with up to two storeys in occupancy class 4 can be constructed with a minimum fire resistance class of EI 30. to Section 5:521 and 5:62 BBR For tents, caravans and similar buildings in occupancy class 4 intended for a maximum of 6 people, a surface finish of at least class E can be used for interior finishes of walls and ceilings, and as roof covering. 3 (7)

general recommendations for temporary accommodation facilities, ATA For tents, caravans and similar buildings in occupancy class 4 intended for more than 6 people, roof covering can consist of either Class B roof (t2) or the same reaction to fire class that applies to internal roof surfaces. to Section 5:61 BBR Occupancy class 3B Buildings in occupancy class 4 in up to two storeys can be placed with a minimum distance of 5 meters between each other, if the exterior walls of both buildings are designed in fire resistance class EI 30 or one of the building s wall is designed in fire resistance class EI 60. Glass partitions without fire resistance rating in opposing exterior walls should be limited to a maximum of 4 m 2 per wall. Tents, caravans and similar buildings in occupancy class 4 can be placed at a minimum distance of 5 meters between each other without requirements for separating structures. to Section 5:353 BBR If the occupancy within a group of residential rooms in occupancy class 3B is equipped with residential sprinklers, devices for early detection and warning in case of fire may consist of interconnected smoke alarm devices. The interconnected smoke alarm devices should be installed in all bedrooms, in the common areas, and near kitchen areas. Alternatively, the devices for warning in case of fire may consist of evacuation alarm activated by residential sprinkler system, and smoke alarm devices. Fire detectors should be installed to the same extent as defined above, but are not required to be interconnected. to Section 5:543 BBR Occupancy class 3A A group of residential rooms in occupancy class 3B should consist of rooms that in total are intended for a maximum of 8 people. Kitchen for personal use should be equipped with a stove guard if the number of residents exceeds 6 people in a group of residential rooms. Design of a stove guard can be verified according to SS-EN 50615: 2015. Mandatory provisions to Section 5 BBR Section 5 If the fire protection is designed corresponding to occupancy class 3A, no adjustments and deviations are allowed. Chapter 3. Protection with regard to hygiene, health and the environment Room height to Section 3:31 BBR In bedrooms for a maximum of 6 people, the room height should not be lower than 2.10 meters. In bedrooms for more than 6 people, the room height should not be lower than 2.40 meters. In bedrooms in tents, caravans and similar buildings, a lower ceiling height can be allowed. In rooms intended for a larger number of people, such as larger residence areas, the room height should not be lower than 2.70 meters. 4 (7)

general recommen-dations for temporary accommodation facilities, ATA Access to daylight Mandatory provisions and general recommendations to Section 6:322 BBR Section 1 Bedrooms shall be designed and oriented so that access to direct daylight is possible. Other rooms where people are present other than occasionally shall allow access to direct or indirect daylight if it is reasonable with regard to the conditions of the building and the intended use of the rooms. Examples of rooms that pursuant to the second paragraph of the provision do not need to have access to direct daylight can be rooms for socializing and leisure activities. to Section 6:33 BBR Air Windows are not required to have a view that provides the opportunity to follow the daylight and seasonal variations. Mandatory provisions to Section 6:21 BBR Section 2 Adjustments and deviations from the requirements for air quality in Section 6:21 BBR are not allowed. Thermal climate to Section 6:42 BBR The requirement for thermal comfort can be assumed to be satisfied if the building is designed so that the air temperature during the day in the occupied zone does not fall below 20 C and does not exceed 26 C for longer periods, and if the floor temperature does not fall below 16 C. The building envelope and heating should be designed so that cold radiation, hot radiation and thermal draughts are limited. Alternatively, the occupied zone can be defined so that the effect of cold radiation, hot radiation and thermal draughts are restricted. Mandatory provisions and general recommendations to Section 6:43 BBR Section 3 The requirement for thermal comfort need not be met by using the building s fixed heating installations if the requirement can be achieved in other ways. Moisture safety In tents, caravans and similar buildings, fixed heating installations can be supplemented or replaced by portable equipment. Mandatory provisions to Section 6:5323 BBR Section 4 For areas under cantilevered bottom floor, deviations from the inspection requirement in Section 6: 5323 BBR are allowed. 5 (7)

general recommendations for temporary accommodation facilities, ATA Water Mandatory provisions to Section 6:622 BBR Section 5 Adjustments and deviations from the requirements for protection against microbial growth in Section 6:622 BBR are not allowed. Chapter 4. Safety in use Child safety Mandatory provisions to Section 8 BBR Section 1 In areas where children can be expected to be present, adjustments and deviations from the requirements for child safety in Section 8 BBR are not allowed. Roof safety Mandatory provisions and general recommendations to Section 8:24 BBR Section 2 Access arrangements to roofs, fixed safety equipment for movement on the roof and safety devices against falls from roofs do not need to be installed if these purposes can be achieved in other ways. Examples of alternative design are the use of construction lift or other portable equipment. Chapter 5. Protection against noise Mandatory provisions and general recommendations to Chapter 3, Section 13 PBO Section 1 In bedrooms, adjustments and deviations from the requirements for protection against noise in Chapter 3, Section 13 PBO are not allowed. In other areas deviations and adjustments are allowed. In bedrooms, the values for guest rooms in hotels pursuant to sound class C in SS-EN 25268:2007 should be achieved. Alternatively, values for room for sleep and rest in residences in accordance with section 7:21 BBR can be used. Chapter 6. Good effect of design, colour and material to Chapter 8, Section 1, 2 PBA Adjustments and deviations can normally be made from the requirement in Chapter 8, Section 1, 2 PBA regarding good shape-, colour- and material effect. 6 (7)

general recommen-dations for temporary accommodation facilities, ATA Chapter 7. Accessibility and usability for individuals with reduced mobility or sense of direction Mandatory provisions to Section 3:113 BBR Section 1 The dimensions of a manual or small electric wheelchair for indoor use (indoor wheelchair) can be used for design of the ground storey and the other storeys intended to be accessible. Mandatory provisions to Section 3:142 and 3:1421 BBR Section 2 For storeys other than the ground storey, adjustments and deviations are allowed from the requirements for accessible and usable entrance and circulation spaces in Section 3:142 BBR and for firm and smooth walking surfaces in the entrance and circulations spaces in Section 3:1421 BBR. Mandatory provisions to Section 3:1422 3:1424 BBR Section 3 Adjustments and deviations from the requirements on the design of ramps in Section 3:1422 BBR, contrasts and markings in Section 3:1423 BBR and lighting for orientation in buildings in Section 3:1424 BBR are not allowed. Mandatory provisions to Section 3:143 BBR Section 4 For storeys other than the ground storey, adjustments and deviations from the requirements for accessible and usable doors and gates in Section 3:143 BBR are allowed. This statute is effective from 1 July 2016. 7 (7)