Installation Instructions

Similar documents
Pet Immune SAW PIR Motion Sensor

Motion Detector. Installation and Usage Guide. Need help? Visit protectamerica.com/chat

Caddx Installation Instructions Package

1125 PIR Motion Detector

NetworX NX-548E Receiver Installation Instructions

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

1126 Series Ceiling Mount PIR Motion Detector

Installation Instructions

Q3200 Smart Home Alarm. Kit Content and Installation Guide

Q3000 Smart Home Alarm. Kit Content and Installation Guide

EWP2WIRELESS MOTION DETECTOR

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

DD205RF/TX Detector Installation Sheet

KwêBeams Effective wire free outdoor early warning system

Commercial Series TriTech+ Motion Detector with Anti-mask

FTP-1000 Touchpad/Display Installation Manual

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

Wireless Occupancy Sensor, Ceiling Mount (WOS2-CM)

Wireless Devices. This chapter introduces the suite of DSC wireless sensors and devices used with the Impassa and other series of DSC alarm systems

Home Doorway Alert Kit

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

Commercial Series TriTech Motion Detector. Reference Guide

DI601AM Outdoor PIR/AM Detector Installation Sheet

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

HX-80NRAM. High Mount Outdoor Detector

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

Wireless External Alarm

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

BATTERY POWERED DETECTOR/ TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTXDCB INSTRUCTIONS

powered by Note: This manual applies to several packages. As such, some parts and some steps may not pertain to the package that you purchased.

HSA % wirefree security alarm system. Installation Programming Operating. Helpline Intelligent Security & Fire Ltd

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

Bosch Smart Home. Motion Detector Instruction Manual

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

English. Italiano. Português. Françias. Español

Wireless Occupancy Sensor, Wall Mount with Photosensor (WOS2-WM)

Pella Insynctive Product Guide

Supervised Security System Owner's Guide

other ambient light sources. Before installation, make sure to read this instruction manual carefully for safe and effective product operation.

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

LUX Hardwired - Installation Notes

Wireless Sensors. Security anywhere. Interlogix wireless sensors deliver highly accurate detection and easy installation for multiple applications.

l High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor.

D-TECT 3 IP. GJD260 IP Motion Detector

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Installation Instructions

ALMDT-2000 INFRARED MOTION SENSOR

Simple Instructions for the WisePIR

PET IMMUNE PIR MOTION DETECTOR

Home & Yard Alert Long Range System Home & Yard Alert Extended Long Range System

Wireless Sensors. Security unplugged. Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications.

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

Detector switch - Dual Tech

READ ME FIRST DIY WIRELESS ALERT. Add-on Alert Sensor. For Swann Wireless Alert systems. Instruction Manual

INSTRUCTION MANUAL FOR: WIRELESS SECURITY STARTER KIT MODEL NO: SWSKIT

Wireless Driveway and Intruder Alert

HSD-200Z Z-Wave Motion Sensor

Flash 3 times per 3 seconds: Under voltage indication, please

Motion Detector User Guide

D-TECT Dual Tech. GJD360 Triple Technology External Detector

SZ-PIR04N ZigBee Motion Detector Installation Guide

Wireless High Bay Sensor (WHS100) Installation Instructions

CONTENTS. La Crosse Technology, Ltd. Page 1

ALSET-2000 WIRELESS SECURITY SYSTEM

WIRELESS THERMO-HYGROMETER Instructions manual Cat. No. WS9070IT+

Campers Alert TM Portable System Hunters Alert TM Portable System

TRUST WIRELESS ALARM SYSTEM 200S

Detector switch - Dual Tech SCS

CONTENTS. La Crosse Technology, Ltd. Page 1

ADT Home Security Starter Kit. Setup Guide

status AW1 Plus WiFi Alarm System User Manual

Total Connect Box. User manual

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Premium 8 Zone Wireless Alarm Kit

>WIRELESS> ALARM SYSTEM CR200

PIR Occupancy & Motion Sensor

Description. Optex Incorporated

Supervised Security System Owner s Manual

Honeywell Temperature & Humidity Sensor with LCD

Wireless Rain Gauge with Rainfall Memory and Digital Clock MODEL: RGR382

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

D-Tect 2 GJD300 Quad PIR Movement Detector

Immunity. P/N: ver.b

Active Infrared Multi Beam Sensors

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

D-TECT 2 IP. GJD230 IP Motion Detector

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Wireless Alarm system s manual

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. COMPOSITE FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES

Active Infrared Multi Beam Sensors. R Series

DS860 Surface or Corner Mount TriTech PIR/Microwave Detector

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM WS-500X CONTENTS REV: 0.2 ERP P/N: ERP 机型 :SS21W2R-AU-EDP09940A-V1

Transcription:

Indoor/Outdoor PIR Motion Sensors 466-1534G August 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Indoor/Outdoor PIR Motion Sensors Installation Instructions for model numbers: 60-639-95R (indoor) 60-639-95R-OD (outdoor) 60-639-43-EUR (indoor, not investigated for use by UL) 60-639-43-ERT-OD (outdoor, not investigated for use by UL) Passive-infrared (PIR) motion sensors detect movement within a specific area by sensing the infrared energy emitted from a body as it moves across the sensor s field of view, causing a temperature change in the sensor s zones. When the sensor detects this motion, it transmits an alarm signal to the control panel. Use the indoor sensors to protect large areas and open floor plans or as backup protection for door/window sensors. Use the outdoor sensors to identify motion in a protected outdoor area. Detected motion in this protected area can sound chimes or turn on outside lights. Do not use the outdoor sensors for intrusion protection. Features include: 35 by 40 ft. (10.7 x 12.2 m) coverage area for standard and optional pet alley lenses; masking kit to block portions of the coverage area; three-minute transmitter lockout time after an alarm to extend battery life; cover-activated tamper (an optional wall-activated tamper is provided); supervisory signal transmitted every 64 minutes to the control panel; sensor low battery reports (trouble) to the control panel; and field-selectable sensitivity options. Indoor sensor installation Use the following installation guidelines: If possible, mount the sensor within 100 ft. (30.5 m) of the panel. While the transmitter may have a range of 500 ft. (152.4 m) or more out in the open, the environment at the installation site can have a significant effect on transmitter range. Position the sensor to protect an area where an intruder is most likely to walk across the detection pattern. (Figure 1). Mount the sensor between 5 and 8 ft. (1.5 and 2.4 m) from the floor (Figure 2). We recommend a height of 7. (2.3 m). Higher mounting provides better range, and lower mounting provides better protection close to the sensor. See Pet alley lens on page 3. Figure 2. Top view 20 ft. 6 m Detection pattern 10 ft. 3 m 0 ft. 0 m 10 ft. 3 m 20 ft. 6 m Side view with mounting height of 7. (2.3 m) 8 ft. (2.4 m) 4 ft. (1.2 m) 0 ft. (0 m) 3 3 Figure 1. Overhead detection pattern Side view with mounting height of () 8 ft. (2.4 m) 4 ft. (1.2 m) 0 ft. (0 m) 3 Side view with pet alley lens and flush mount 8 ft. (2.4 m) 4 ft. (1.2 m) 0 ft. (0 m) 3

2 Indoor/Outdoor PIR Motion Sensors Mount the sensor on a rigid surface that is free of vibrations. Do not aim the sensor at windows, fireplaces, air conditioners, area heaters, or forced air heating vents. Do not place it in direct sunlight. Sudden changes in temperature may trigger a false alarm. Do not mount the sensor near duct work or other large metallic surfaces that may affect the RF signals (see Testing on page 4). Verify actual transmitter range for each installation. Mount the sensor permanently on a flat wall or in a corner. Do not set it on a shelf. Mount the sensor on an insulated, outside wall facing in. Position the sensor so it faces a solid reference point, such as a wall. Close all windows in an area with an armed motion sensor. A pet will trigger a motion sensor. See Pet alley lens on page 3 to use a motion sensor when pets are present. You can flush-mount, incline-mount, or corner-mount the sensor depending on the lens used. Use the optional swivel mount (part number 60-737) for difficult mounting locations (Figure 3). Note: The wall-tamper switch cannot be used when you mount the sensor in a corner or on the swivel mount. To mount the sensor, do the following: 1. To remove the mounting plate, depress the button on the top of the sensor (Figure 4) and pull the mounting plate away from the sensor. Figure 4. Tabs Sensor parts Sensor cover Lens Battery Figure 3. Mounting options Flush mount Inclined mount Mounting plate Tamper switch Sensor body 2. Punch out the mounting holes applicable for your installation (Figure 5). Use the lower-side holes for corner mounting, or the lower-back holes for surface-mounting with the standard lens. For applications with pets, use the upper mounting holes and the optional pet alley lens. Figure 5. Mounting plate knockouts Corner mount Swivel mount Pet alley lens knockouts Pet alley lens knockouts Wall tamper knockout Standard lens knockouts 3. If you want wall-tamper functionality, remove the walltamper knockout (Figure 5). 4. Mark the location of the required holes on the mounting surface. 5. Use wall anchors and screws to secure the mounting plate in place. Attach the sensor to the mounting plate. 6. Test the sensor in place (see Testing on page 4), then screw the housing screw (the smallest screw provided) into the hole at the top of the mounting plate.

3 Lens replacement To change the lens, do the following: 1. Depress the button on the top of the sensor and pull the sensor from the mounting plate. 2. Depress the two tabs on the top and the one tab on the bottom of the sensor body and slide the cover off (Figure 4 on page 2). 3. To remove the lens, gently place pressure on the lens from the outside of the lens. 4. Align the new lens s notches with the tabs in the cover. Install the new lens with the smooth side facing out and the grooved side facing in. 5. Slide the cover on the sensor and attach the sensor to the mounting plate. Pet alley lens The optional pet alley lens (part number 60-709) provides protection in installations where pets move about freely. See Figure 2 on page 1 for the coverage pattern. Follow these guidelines for installations with the pet alley lens: Mount the sensor 3 to (0.9 x ) high. For best results, install the sensor higher than the highest point the pet might reach in the detection area. If the detection area contains furniture or other objects that the pet can climb or jump on, either remove these objects, mount the sensor a safe distance above these objects, or mask these areas. Be sure to flush-mount or corner-mount the sensor with the back of the sensor parallel to the walls. Do not use the inclined-mount position because this will tilt the sensor s field of view downward. Position the sensor so that is has a clear line of sight across the protected room. Sensitivity settings The sensor is set to standard sensitivity at the factory. This sensitivity is preferred for most applications and provides the best immunity to false alarms. To change the sensitivity setting, do the following: 1. Depress the button on the top of the sensor and pull the sensor from the mounting plate (Figure 4 on page 2). 2. Depress the two tabs on the top and the one tab on the bottom of the sensor body and slide the cover off (Figure 4 on page 2). 3. Looking at the front of the sensor, locate the sensitivity pins under the battery on the right side (Figure 6). Figure 6. CAUTION: Sensitivity pins High sensitivity should only be used in extremely quiet environments where thermal transients are not expected. Standard High 4. To change to high sensitivity, move the shorting jumper to the pair of pins that are closer to the top of the sensor (Figure 6). Note: If the shorting jumper is not used or is placed incorrectly, the sensor defaults to standard sensitivity. 5. Walk test the sensor (see Testing) to verify sensitivity. Slide the cover on the sensor and attach the sensor to the mounting plate.

4 Indoor/Outdoor PIR Motion Sensors Outdoor sensor installation Use the following guidelines for outdoor installations: Use the outdoor sensors for outdoor applications with a temperature of 10 to 120 F (12 to 49 C). Do not use outdoor sensors for intrusion protection because any human, pet, or heated mechanical motion such as an automobile can activate the sensor. Follow the indoor sensor installation guidelines (see Indoor sensor installation on page 1), except for the last four items. Do not aim the sensor at objects that may be heated excessively by the sun, such as blacktop or dark-colored objects. The sensor housing is water-resistant, but not water-proof. Mount the sensor underneath eaves or porch coverings to prevent exposure to rain, ice, and direct sunlight. To mount the sensor, do the following: 1. Determine the mounting location for the sensor. Leave at least 4 in. (10 cm) of room above the wall mount plate to attach the sensor. 2. Use the supplied screws and anchors to attach the wallmount plate with the opening for the swivel mount facing downward. 3. To attach the sensor assembly to the wall-mount plate, screw the sensor assembly up into the opening in the wallmount plate. 4. To remove the sensor for testing or battery replacement, slide the front cover of the sensor upward until you can remove the sensor. Filter installation A 1 in. (2.5 cm) piece of lens material is included with the outdoor sensors. The filter reduces the sensors sensitivity to white light sources (sunlight and head lights) and infrared sources. Install the filter when you experience unwanted sensor activations due to these sources. To install the filter, do the following: 1. Slide the front cover upward untill you can remove the sensor from its enclosure (Figure 4 on page 2). 2. Depress the button on top of the sensor to remove the mounting plate. 3. Depress the two tabs on the top and the one tab on the bottom of the sensor and slide the cover off. 4. Place the sensor on its back and drop the filter into the lens chamber covering the sensor s detector. 5. Replace the cover, making sure the filter remains in the lens chamber and does not interfere with the attachment of the cover. 6. Replace the sensor s mounting plate and install the sensor in its enclosure. Programming Refer to the panel installation instructions for information on programming the sensor into the panel. Testing Testing the sensor includes a walk test, an environment test, and a final test with the control panel. Walk test Walk test the unit from both directions to determine the pattern boundaries. The edge of the coverage pattern is determined by the first flash of the LED. This may change slightly depending on the sensitivity setting. To walk test the sensor, do the following: 1. Remove the sensor from the mounting plate to activate the tamper switch and remount the sensor on the mounting plate to start the 60-second walk test mode. 2. Walk across the coverage pattern to determine the coverage area, indicated by the LED activation. Each activation extends walk test mode for an additional 60 seconds. After 60 seconds without motion, walk test mode and the LED will no longer activate when motion is detected. When walk test mode has ended, an alarm can be transmitted only after three minutes have passed since the previous alarm. This three-minute lockout time reduces unnecessary RF transmissions in high traffic areas and extends battery life. Note: Excessive use of walk test mode may reduce battery life. Use only for initial setup and maintenance testing. Environment test For indoor sensors, turn on all heating or air conditioning sources that are normally active during the protection period. Stand away from the sensor outside the coverage pattern and watch for alarms. For outdoor sensors, verify that the sensor s coverage area does not extend into undesired areas that might cause unwanted activations. These areas include undesired human, pet, and automobile motion. Coverage masks After you complete the walk test and environment test, you can use the masking labels provided to block detection of problem areas. The masking labels are cut to match the corresponding lens segments. To mask coverage areas, do the following: 1. Determine which detection zone/lens segment needs a masking label. 2. Peel the appropriate mask label from its backing and apply it to the inside of the lens segment to be blocked. Final test Do a final test to verify radio signal integrity and confirm control panel programming and response. To test the sensor with the control panel, do the following: 1. Remove the sensor from the mounting plate to activate the tamper switch and the sensor s walk test mode. 2. Replace the sensor on the mounting plate. 3. Place the control panel in sensor test mode. Walk across the sensor s detection pattern until the sensor s LED turns on. Stop your motion. 4. Listen for the appropriate system response. If the system does not respond properly, see Troubleshooting on page 5.

5 Maintenance Test the sensor at least once a year to verify proper range and coverage. Instruct the end user to put the sensor in walk test mode and walk through the end of the coverage pattern to verify proper detection. Battery replacement When you replace the batteries, observe proper polarity (as shown in the battery compartment) to avoid damage to the sensor. CAUTION: Replace only with two AA 1.5 V alkaline batteries. Dispose of used batteries according to the manufacturer s instructions and local government authorities. To replace the batteries, do the following: 1. Remove the sensor from the mounting plate and slide the cover off the sensor to reveal the battery compartment. 2. Remove the batteries and replace with the new ones. Be sure to observe polarity. As you look at the battery compartment, on the left side the positive end is down and on the right side the positive end is up (Figure 4 on page 2). 3. Wait at least three minutes after installing the batteries before you activate walk test mode. Troubleshooting If the system doesn t respond correctly when the sensor is activated, follow these guidelines: Check sensor programming (refer to the panel s programming instructions) and reprogram the sensor if necessary. Move the sensor to another location and test for correct response. To relocate the sensor, do the following: 1. Test the sensor a few inches from the original position. 2. Increase the distance and retest until you find an acceptable location. 3. Mount the sensor in the new location. If no location is acceptable, do the following: 1. Test a known good sensor at the same location. 2. If the system does not respond, avoid mounting a sensor at that location. 3. If the replacement sensor functions, return the problem sensor for repair.

6 Indoor/Outdoor PIR Motion Sensors Specifications Compatibility Power source Typical battery life Transmitter frequency Operating temperature Indoor sensor Outdoor sensor Storage temperature Maximum relative humidity Dimensions (L x W x H) Concord, Concord Express, International Concord, Simon, Euro Simon, Quik Bridge 1 and 2 Channel Receiver, Quik Bridge Euro Repeater SAW, Quik Bridge International Loop Receiver, SuperBus 2000 RF Receiver, SuperBus 2000 433 MHz Receiver 2 AA 1.5 V alkaline batteries 2 to 4 years at 68 F (20 C) not verified by UL 319.5 MHz 32 to 120 F (0 to 49 C) 10 to 120 F (12 to 49 C) -30 to 140 F (-34 to 60 C) 90% relative humidity noncondensing 2.9 x 2.4 x 1.9 in. (74 x 61 x 48 mm) Sensor models 60-639-43-EUR and 60-639-EUR-OD are approved for use in the following countries: Austria Denmark France Germany Ireland Italy Netherlands Portugal Spain Sweden Product identification: Model/type Category Brand Manufacturer: EU representative: Manufacturers Declaration of Conformity 60-639-43-EUR and 60-639-43-EUR-OD Indoor and outdoor PIR motion sensors GE Security GE Security 1275 Red Fox Road Arden Hills, MN 55112 GE Security, B.V. Kelvinstraat 7 6003 DH Weert The Netherlands Concerning R&TTE A sample of the product Mike Product Services KTL Arnhem has been tested by: Standards used: I-ETS 3000 220 (10.1993) EN50130-4 (1995) EN50130-4/A1 (1998) EN60950, 1992 (A1, A2, A3, A4, A11) IEC950, 2nd ed. (A1, A2, A3, A4) Test report: T14152-1-02SM 98639220 98639250 Means of conformity We declare under our sole responsibility that this product is in conformity with Directive 93/68/EEC (CE Marking) and complies to the essential requirements of 1999/5/EC (R&TTE) based on test results using (non)-harmonized standards in accordance with the Directives mentioned. Technical support Toll-free: 888.GESECURity (888.437.3287 in the US, including Alaska and Hawaii; Puerto Rico; Canada). Outside the toll-free area: Contact your local dealer. www.gesecurity.com