JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

JENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD ARJONS DR., SUITE C P.O. BOX LINKOU-117

1 4 DIN Dissolved Oxygen Controller

203RE ph v 1.0 Instructions

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

Model Q45P/R. ph/orp Monitor...

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Model Q45P/R. ph/orp Monitor...

Use this Specification Template to develop a specification to be used for requesting a quote or defining a job work description.

UDC100 Universal Digital Controller Specifications

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

UDC 700 Universal Digital Controllers and Indicator Specifications

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Dual Input ph/orp Analyzer

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

Dual Input ph/conductivity Analyzer

HT4700 Heating Jacket Instruction Manual

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

Rosemount 372. HF Resistant ph sensor. Quick Start Guide LIQ-QSG-372 Rev. C June 2017

99 Washington Street Melrose, MA Phone Toll Free Visit us at

RATIO:GUARD Model E-1S EC Monitor

Process & TeMPerATUre UniversAl input DigiTAl MeTers

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

User s Guide. CN606 / 612 AC Series & CN606 / 612 DC Series CONTRONAUTICS INCORPORATED. Table of Contents.

Inductive. Range. S410/IND Electrodeless Conductivity Sensors

Operating Instructions. For. Alarm Control Module. Model SSR 500

MS200/300/400 Hotplate Magnetic Stirrer Instruction Manual

Instruction Manual Model A

Model OEM-2 INSTRUCTIONS FOR USE

Nov 08 PRODUCT SPECIFICATION SHEET

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX (951) Growmate Growmate Plus

A2CM2 Dual Wire Continuous Resistance Monitor

Dual Input Toroidal Analyzer

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Temperature Controllers

INSTALLATION INSTRUCTIONS

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Table of Contents SECTION PAGE

Global Water Instrumentation, Inc.

INSTALLATION INSTRUCTIONS

Ohm Metrics. Instruction Manual. Continuous Workstation Monitors Model CM1600. T r a n s f o r m i n g T e c h n o l o g i e s, L L C

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Alarm Tone Generator Model AG17

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

INSTALLATION INSTRUCTIONS

eed quality electronic design USER s MANUAL

Duct Humidity/Temp Sensor

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

OPERATING MANUAL BFS-MP SERIES FREEZING STAGES

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Warranty Registration

Electronic Flow Switches

The next generation thermometer from the global leader

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

MEAS CAL ALARM WASH CONF APT4000 TC

Instruments. for hydroponics & horticulture 2016

I/A Series 716C 1/16 DIN Temperature Controller

USER GUIDE. RLH Auxiliary Fan Kit. Description. The leader in rugged fiber optic technology. ENCLOSURE TEMPERATURE CONTROL. RLH Industries, Inc.

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

DIGITAL INDICATOR JIR-301-M

GAS MONITOR Model Model

QAS-101 SERIES SINGLE CHANNEL CONTROLLERS

Specification , July 2015

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

Toroidal Conductivity Transmitters Series APT4000 Specifications

WH EN IGH T T C LO SED

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Model 96VTR ¼ DIN Process Controller

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM FX SERIES FLOW SWITCH WITH ADDITIONAL TEMPERATURE SWITCH. Manual Number: FXTX2116-1

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

High Pressure Conductivity Monitor

Figure 1 DirectLine DL423 Sensor. Description, continued

ph/orp-7500 ph/orp Transmitting controller Operation manual

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

Instruction Manual for HX-DX and HX-DXHP Heat Exchangers 3 / 2017

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

M3050 Detector Operator s Manual

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

Dual Laser InfraRed (IR) Thermometer

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. DIGITAL CHILLING INCUBATOR MODELS MD5-600, MD5-602, AND MD5-604

Hydrazine Analyzer Series 2171 Specifications

Concise catalogue Water-Industry

VEHICLE EXHAUST DETECTOR

Microprocessor Based 16 Channel Temperature Scanners (Product Code 7.2 To 7.3) MSI-16-H

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

MICRO GROW GREENHOUSE SYSTEMS, INC

ECA-DIN. Users Manual. Current and Voltage Alarms. March 2018

FUSE PANEL Technical Practice N N/L9 10/10 GMT NEBS Level 3 Certified

Excellence through Versatility

Transcription:

OPERATION MANUAL THE JENCO MODEL 3677 1/8 DIN ph/orp CONTROLLER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISON INSTRUMENTS

GENERAL INTRODUCTION The model 3677 is a precise instrument for the measurement and control of ph and mv (ORP). Two output relays are provided in the model 3677 for ON\OFF control. The isolated 4-20 ma output current of the model 3677 covers the input range of 0 to 14 ph and 0 to 1400 mv. A front panel programmable HIGH\LOW ALARM relay is provided in the model 3677. A large LCD display is used for readability under bright ambient conditions. The model 3677 is housed in a rugged 1/8 DIN plastic case, allowing it to fit into standard panel cut-outs as well as the most commonly available industrial weatherproof and environmental housings. INITIAL INSPECTION Carefully unpack the instrument and accessories. Inspect for damage in shipment. If any damage is found, NOTIFY YOUR JENCO REPRESENTATIVE IMMEDIATELY. All packing materials should be saved until satisfactory operation is confirmed. 1

TEMPERATURE COMPENSATION The model 3677 is designed to be used with a PT-100 RTD temperature probe for automatic temperature compensation, ATC, operations. The alpha value of the PT-100 element is 0.00385. A precision 0.1% resistor can be connected across the ATC input terminals to simulate a fixed process temperature. Temperature in 0 10 20 25 30 40 50 60 70 80 90 100 Table 1 2 Resistor value in Ohms 100.00 103.90 107.79 109.73 111.67 115.54 119.40 123.24 127.07 130.89 134.78 138.50

REAR PANEL CONNECTION PROCEDURE (REFER TO FIGURE 1 AND FIGURE 2) 1. Connect the AC line to the rear terminal of the instrument. The instrument can be powered by 115VAC or 230VAC, 50/60Hz. Make sure that the EARTH terminal is connected to the earth of AC power line. 2. Connect the proper load to the output relays. Be sure that the load does not exceed the relay rating, 5 Amp at 115VAC and 2.5 Amp at 230VAC for RESISTIVE load only. 3. Set the ph/mv switch to the position for ph or mv operations. (REFER TO FIGURE 3) 4. Load connections Connect the proper load to 4-20 ma output terminals. Make sure that the load impedance is less than 550 Ohms and the common mode voltage does not exceed 500 VDC. (Output terminals : OUT + and OUT - ) 3

5. Electrode connections 1) Combination ph (mv) electrodes Connect the ph (mv) electrode cable to the ph/mv electrode input connector. 2) Separate ph (mv) electrodes Connect the working electrode to the ph/mv electrode input connector. Connect the reference electrode to the Reference input terminal. 6. Temperature compensation input connections 1) ATC mode Connect the automatic temperature compensation, ATC, probe to the ATC input terminals, T-T. 2) A precision 0.1% resistor can be connected across the ATC terminals to simulate a fixed process temperature. (REFER TO TABLE 1) 4

FIGURE 1 FRONT PANEL FORMAT 5

FIGURE 2 REAR PANEL FORMAT 6

FIGURE 3 ph/orp SWITCH SETTING 7

MOUNTING PROCEDURE 1. Make a cutout on any panel, with a thickness of 1/16 inch (1.5 mm) to 3/8 inch (9.5 mm). (REFER TO FIGURE 4) 2. Remove the mounting brackets assembly from the panel meter and insert the panel meter into the cutout. (REFER TO FIGURE 5) 3. Replace the mounting brackets assembly onto the panel meter and fasten the mounting screws to secure the panel meter to the mounting panel. (REFER TO FIGURE 6) 8

9

FIGURE 5 PANEL METER WITH MOUNTING BRACKET AND SCREW 10

FIGURE 6 MOUNTING METHOD 11

ph CALIBRATION (REFER TO REAR PANEL CONNECTION PROCEDURE AND TEMPERATURE COMPENSATION SECTIONS) 1. Rinse the ph electrode and ATC probe with distilled water. 2. Measure the temperature of the buffer 7 solution with a precision thermometer. 3. Immerse the ph electrode and ATC/TEMP probe in buffer 7. Allow sufficient time for the electrode and ATC probe to reach temperature equilibrium with the buffer 7. 4. Adjust the STAND control for the instrument to display the buffer value corresponding to the temperature measured in 2. (REFER TO TABLE 2) 5. Remove the ph electrode and ATC probe from buffer 7 and rinse with distilled water. 6. Measure the temperature of a second buffer with a precision thermometer. 7. Immerse the ph electrode and ATC probe in the second buffer. Allow sufficient time for the ph electrode and ATC probe to reach temperature equilibrium with the second buffer. For accurate ph measurements, the second buffer should be close in ph and temperature values to process under test. In practice, ph buffers 4 and 10 are commonly used. 8. Adjust the SLOPE control for the instrument to display the buffer value corresponding to the temperature measure in 6. (REFER TO TABLE 2) 9. Remove the ph electrode and ATC probe from the second buffer and rinse with distilled water. The instrument is dual point calibrated and ready for measurement. 12

TEMPERATURE COEFFICIENT OF THE ph BUFFERS BUFFERS 10.01 7.00 4.01 0 5 10 15 20 25 30 35 40 45 50 55 60 10.32 10.25 10.18 10.12 10.06 10.01 9.97 9.93 9.89 9.86 9.83 9.80 9.78 7.11 7.08 7.06 7.03 7.01 7.00 6.98 6.98 6.97 6.97 6.97 6.97 6.98 4.00 4.00 4.00 4.00 4.00 4.01 4.02 4.02 4.03 4.04 4.06 4.07 4.10 TABLE 2 13

ISOLATION VOLTAGE The differential voltage between the outputs and the load should mot exceed the maximum values. Exceeding maximum values may cause permanent damage to the instrument and load. 1. Relay output The maximum isolation voltage of the relay output contacts is 1500VDC. The voltage differential between the relay output contacts and the load should not exceed 1500 VDC. 2. Current output The maximum isolation voltage of the 4-20 ma output is 500 VDC. The voltage differential between the 4-20 ma output and the load should not exceed 500 VDC. CONTROLLER OUTPUT FEATURES OF THE MODEL 3677 The output of the model 3677 consists of two alarm relays and an isolated 4-20 ma output. The operation of the 3677 is described in the following sections.(refer TO FIGURE 1, FIGURE 2) 14

CONTROLLER INPUT RANGE 1. Relay outputs ph mv 2. Current output ph mv 0 to 14.00 ph 1999mV 0 to 14.00 ph 0 to 14.00 mv ALARM RELAY AND LED LAMP FORMATS 1. HIGH ALARM set point 1) Press the HIGH ALARM SET POINT switch. The instrument will indicate the alarm set point value. The alarm set point value can be adjusted by the HIGH ALARM SET POINT control. 2) Release the HIGH ALARM SET POINT switch. The instrument will indicate the measured process value. 3) The HIGH ALARM SET POINT LED will be ON and the HIGH ALARM output relay will be energized when the measured value is greater than the alarm set point value. The HIGH ALARM SET POINT LED will be OFF and the HIGH ALARM output relay will be de-energized when the measured value is 15

less than the alarm set point value. 2. LOW ALARM set point 1) Press the LOW ALARM SET POINT switch. The instrument will indicate the alarm set point value. The alarm set point value can be adjusted by the LOW ALARM SET POINT control. 2) Release the LOW ALARM SET POINT switch. The instrument will indicate the measured process value. 3) The LOW ALARM SET POINT LED will be ON and the LOW ALARM output relay will be energized when the measured value is less than the alarm set point value. The LOW ALARM SET POINT LED will be OFF and the LOW ALARM output relay will be de-energized when the measured value is greater than the alarm set point value. 3. Set point hysteresis The hysteresis of the model 3677 is factory set to 0.1 ph ( 10 mv). FOR HIGH ALARM set points, the trigger ON point is 0.1 ph (10 mv) above the set point values and the trigger OFF point is 0.1 ph (10 mv) below the set point values. FOR LOW ALARM set points, the trigger ON point is 0.1 ph (10 mv) below the set point values and the trigger OFF point is 0.1 ph (10 mv) above the set point values. 16

ISOLATED 4-20 ma OUTPUT 1. ph mode output The 4-20 ma output is 4 ma at 0 ph and 20 ma at 14 ph. The ph value can be obtained by measuring the output current, A, based on the following equation. (REFER TO FIGURE 7) ph = (A-4) (14/16) Example : A = 12 ma for ph = 7.00 2. mv mode output The 4-20 ma output is 4 ma at 0 mv and 20 ma at 1400 mv. The mv value can be obtained by measuring the output current, A, based on the following equation (REFER TO FIGURE 7) mv = (A-4) (1400/16) Example : A = 12 ma for mv = 700 17

FIGURE 7 18

WARRANTY Jenco Instruments, Ltd. Warrants this product to be free from significant deviations in material and workmanship for a period of 1 year from date of purchase. If repair or adjustment is necessary and has not been the result of abuse or misuse, within the year period, please return-freight-prepaid and the correction of the defect will be made without charge. If you purchased the item from our Jenco distributors and it is under warranty, please contact them to notify us of the situation. Jenco Service Department alone will determine if the product problem is due to deviations or customer misuse. Out-of warranty products will be repaired on a charge basis. RETURN OF ITEMS Authorization must be obtained from one of our representatives before returning items for any reason. When applying for authorization, please have the model and serial number handy, including data regarding the reason for return. For your protection, items must be carefully packed to prevent damage in shipment and insured against possible damage or loss. Jenco will not be responsible for damage resulting from careless or insufficient packing. A fee will be charged on all unauthorized returns. 19

NOTE: Jenco Instruments, Inc reserves the right to make improvements in design, construction, and appearance of our products without notice. JENCO INSTRUMENTS, INC. 7968 Arjons Drive, Suite C San Diego, CA 92126 USA TEL: 858-578-2828 FAX: 858-578-2886 E-MAIL: jencoi@ix.netcom.com JENCO ELECTRONICS, LTD. PO. BOX LINKOU 117 TAIPEI, TAIWAN TEL: 02 601-6191 FAX: 02 601-7206 E-MAIL: jencoe@ms2.hinet.net SHANGHAI JENCO ELECTRONICS, LTD. 18 Wang Dong Zhong Road Sijing Town,Songjiang SHANGHAI,CHINA TEL: (86-021)5761-9599 FAX: (86-021)5761-9598 E-MAIL: jenco@public.sta.net.cn Homepage: http://www.jenco.com.cn 20