SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

Similar documents
SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

R-410A. NJ-10 thru -20, 4-Pipe Ton, 60 Hertz TABLE OF CONTENTS LIST OF TABLES LIST OF FIGURES

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

R-410A. NJ-10 thru -20, 4-Pipe Ton, 60 Hertz TABLE OF CONTENTS LIST OF TABLES LIST OF FIGURES

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

ACCESSORY KIT INSTALLATION INSTRUCTIONS

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

C13-Series Engineering Guide

VertiCool Aurora Engineering Guide

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

INSTALLATION INSTRUCTION

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

MODELS K2EU060A, K4EU090A, & K3EU120A

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

INSTALLATION INSTRUCTION

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

INSTALLATION INSTRUCTION

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

SPLIT-SYSTEM EVAPORATOR BLOWER (AIR COOLED) INSTALLATION INSTRUCTION Supersedes: Nothing N4C-0500

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

COMMERCIAL AIR HANDLER

ACCESSORY INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY 10, 16, 26, 36 & 72

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

VariCool VAV Engineering Guide

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

INSTALLATION INSTRUCTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION


Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

COMMERCIAL AIR HANDLER

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 60 HZ MODELS: EF-10 & FF-10

technical guide Water-Cooled Self-Contained Units

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: F6FP DESCRIPTION FEATURES UTG-B-0409

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

INSTALLATION INSTRUCTION

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

INSTALLATION MANUAL (AIR COOLED) SPLIT-SYSTEM AIR CONDITIONER MODEL: LA120 NOTES, CAUTIONS AND WARNINGS SAVE THIS MANUAL B-0203

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Split System Heat Pumps

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Water-Cooled Self-Contained Units

INSTALLATION MANUAL AFFINITY SERIES SINGLE PACKAGE AIR CONDITIONERS ELECTRIC/ELECTRIC, AIR-COOLED. MODELS: D1EB036 thru Thru 5 Ton (10 SEER)

INSTALLATION MANUAL SINGLE PIECE STANDARD ECM AIR HANDLERS MODELS: AHX61 SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Commercial High-Efficiency Condensing Units

SPLIT-SYSTEM CONDENSING UNITS. "HRC" Series SEER. Models H*RC018 thru H*RC060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

RSG16**S1M. Split System Air Conditioner 16 SEER

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

Submittal Summary Page

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

MODELS B1PA024, 030 AND 036

APPLICATION DATA SHEET

INSTALLATION MANUAL COMMERCIAL SPLIT SYSTEM COOLING UNITS 4 PIPE SYSTEMS 15 THROUGH 20 NOMINAL TON HB B-0804

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM HEAT PUMP FOUR PIPE SYSTEM DESCRIPTION E*FB180 & 240 F*EH180 & & 20 NOMINAL TONS INDOOR UNIT

Vertical Upflow Horizontal Left Air Handlers

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

CoolSpot Engineering Guide

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

36,000-62,000 BTUH Nominal Capacity

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

R-410A AFFINITY SERIES

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Product Data. 40RUA/40RUS 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units FEATURES/BENEFITS. Indoor air quality features

Bosch BVA Series Air Handler

Transcription:

SUBMITTAL DATA SHEET SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE JOB NAME: LOCATION: PURCHASER: ORDER NO: ENGINEER: SUBMITTED TO: FOR: REF: APPROVAL: CONSTRUCTION: SUBMITTED BY: DATE: UNIT DESIGNATION: SCHEDULE NO. MODEL NO. PRODUCT DATA Cooling Performance Total Capacity............... MBH Sensible Capacity............ MBH Evaporator Pressure at Saturation................. PSIG Evaporator Temperature at Saturation................... F Total Supply Air.............. CFM Temp. of air Entering Evaporator Coil......... / F DB/WB Heating Performance Refer to field-installed accessories on reverse side. Supply Air Blower Performance Total Supply Air.............. CFM Total Resistance External To Unit................... IWG Blower Speed................ RPM Blower Output Requirement.... BHP Motor Rating................. HP Power Input Requirement....... KW Electrical Data Power Supply.................. / / Total Unit Ampacity......... AMPS Minimum Wire Size.......... AWG (Copper Conductors) Maximum Fuse Size Dual Element............. AMPS Unit Weight Total Operating Weight....... LBS (Including field-installed accessories) FEATURES R-410A REFRIGERANT POWDER PAINT FOR DURABILITY INHERENTLY PROTECTED FAN MOTORS SINGLE AND DUAL REFRIGERATION CIRCUITS (SINGLE ON NH AND DUAL ON NJ MODELS) PROVISIONS FOR HOT GAS BYPASS CSA APPROVAL 2 AND 4 FILTER RACK (4 FILTERS FIELD SUPPLIED) ELECTRIC HEAT (FIELD INSTALLED) HOT WATER HEATING COILS (FIELD INSTALLED) STEAM HEATING COILS (FIELD INSTALLED) FACTORY SELECTABLE MOTOR AND DRIVE OPTIONS ADJUSTABLE TXV S CAN BE APPLIED VERTICALLY OR HORIZONTALLY SINGLE POINT POWER CONNECTION ONE YEAR LIMITED PARTS WARRANTY ON COMPLETE UNIT 5 YEAR LIMITED WARRANTY ON ELECTRIC HEATING ELEMENTS DESIGNED TO OPERATE WITH COOLING ONLY UNITS OR HEAT PUMPS NH/NJ-20 INDOOR UNIT Johnson Controls Unitary Products 506447-CSD-A-0209

Corner Weights & Center of Gravity NH/NJ Units Model Options Weight (lbs.) Center of Gravity (in.) 4 Point Load Location (lbs.) 6 Point Load Location (lbs.) Shipping Operating X Y A B C D A B C D E F Vertical Airflow NH-07 Std. Mtr. and Drv. 357 381 30 30 102 102 88 88 68 68 68 59 59 59 High Static Mtr. and Drv. 357 385 30 30 103 103 89 89 69 69 69 60 60 60 NH/NJ-10 Std. Mtr. and Drv. 422 468 30 30 125 125 109 109 84 84 84 72 72 72 High Static Mtr. and Drv. 422 492 31 29 123 132 123 115 81 85 89 83 79 76 NH/NJ-15 Std. Mtr. and Drv. 560 632 36 36 139 167 178 148 90 101 115 122 108 96 High Static Mtr. and Drv. 560 661 36 35.5 143 172 189 157 93 104 118 130 114 102 NH/NJ-20 Std. Mtr. and Drv. 715 816 32 48 186 212 223 195 121 132 145 152 139 127 High Static Mtr. and Drv. 715 854 32 47 190 217 238 208 124 135 148 162 148 136 Horizontal Airflow NH-07 Std. Mtr. and Drv. 357 381 15 30 102 102 88 88 68 68 68 59 59 59 High Static Mtr. and Drv. 357 385 15 30 103 103 89 89 69 69 69 60 60 60 NH/NJ-10 Std. Mtr. and Drv. 422 468 15 30 125 125 109 109 84 84 84 72 72 72 High Static Mtr. and Drv. 422 492 15.5 29 123 132 123 115 81 85 89 83 79 76 NH/NJ-15 Std. Mtr. and Drv. 560 632 18 36 139 167 178 148 90 101 115 122 108 96 High Static Mtr. and Drv. 560 661 18 35.5 143 172 189 157 93 104 118 130 114 102 NH/NJ-20 Std. Mtr. and Drv. 715 816 16 48 186 212 223 195 121 132 145 152 139 127 High Static Mtr. and Drv. 715 854 16 47 190 217 238 208 124 135 148 162 148 136 LEFT A B A B C LEFT A B A B C FRONT WIDTH CG REAR FRONT WIDTH CG REAR DIM Y DIM Y F D E D C F D E D C DIM X LENGTH RIGHT VERTICAL POSITION DIM X LENGTH RIGHT HORIZONTAL POSITION 2 Johnson Controls Unitary Products

UNIT DIMENSIONS NH-07/-10 & NJ-10 TOP VIEW 15.63 20.19 18.60 17.62 5.10 5.08 13.44 15.90 ELECTRIC HEAT CONNECTION ELECTRIC HEAT CONNECTION 4.68 4.68 18.44 TOP VIEW - BLOWER OUTLET NH-07 INDOOR 18.44 TOP VIEW - BLOWER OUTLET NH/NJ-10 INDOOR FRONT AND SIDE VIEW 9.06 30.00 2.59 5.09 Ø 1.09 KNOCKOUT POWER ACCESS Ø 0.88 KNOCKOUT CONTROLS ACCESS 66.09 65.00 35.00 SYSTEM 2 7.43 6.44 5.54 4.16 FIELD PIPING CONNECTIONS 20.34 12.23 SYSTEM 1* 9.84 10.1411.87 53.44 DRAIN CONNECTION 3/4 PVC PIPE CONNECTIONS 6.54 1.42 56.16 FRONT VIEW - RETURN AIR NH-07 / -10 & NJ-10 INDOOR RIGHT SIDE VIEW - DRAIN PIPING/CONTROLS *SYSTEM 1 USED FOR 2-PIPE DIMENSIONS *SEE UNITS PHYSICAL DATA TABLE FOR PIPING AND ELECTRICAL SIZE CONNECTIONS Johnson Controls Unitary Products 3

UNIT DIMENSIONS (CONT.) NH/NJ-15 TOP VIEW 21.58 26.46 3.44 18.91 ELECTRIC HEAT CONNECTION 10.23 24.71 TOP VIEW - BLOWER OUTLET NH/NJ-15 INDOOR FRONT AND SIDE VIEW 9.06 33.00 2.59 5.09 Ø 1.09 KNOCKOUT POWER ACCESS Ø 0.88 KNOCKOUT CONTROLS ACCESS 76.09 75.00 27.34 4 SYSTEM 2 7.43 6.44 5.54 4.16 FIELD PIPING CONNECTIONS 71.94 74.66 FRONT VIEW - RETURN AIR NH/NJ-15 INDOOR SYSTEM 1* DRAIN CONNECTION 3/4 PVC PIPE CONNECTIONS RIGHT SIDE VIEW - DRAIN PIPING/CONTROLS *SYSTEM 1 USED FOR 2-PIPE DIMENSIONS *SEE UNITS PHYSICAL DATA TABLE FOR PIPING AND ELECTRICAL SIZE CONNECTIONS 6.54 1.42 9.84 10.1411.87 12.23 4 Johnson Controls Unitary Products

UNIT DIMENSIONS (CONT.) NH/NJ-20 TOP VIEW 18.63 54.65 18.63 25.37 23.62 4.94 5.11 ELECTRIC HEAT CONNECTION 15.90 ELECTRIC HEAT CONNECTION 5.56 23.47 TOP VIEW - BLOWER OUTLET NH/NJ-20 INDOOR FRONT AND SIDE VIEW 9.06 30.00 2.59 5.09 Ø 1.09 KNOCKOUT POWER ACCESS Ø 0.88 KNOCKOUT CONTROLS ACCESS 66.10 65.00 20.34 35.00 SYSTEM 2 7.43 6.44 5.54 4.16 FIELD PIPING CONNECTIONS 95.94 98.66 FRONT VIEW - RETURN AIR NH/NJ-20 INDOOR 45.97 *SEE UNITS PHYSICAL DATA TABLE FOR PIPING AND ELECTRICAL SIZE CONNECTIONS SYSTEM 1* DRAIN CONNECTION 3/4 PVC PIPE CONNECTIONS 6.54 1.42 9.84 10.1411.87 RIGHT SIDE VIEW - DRAIN PIPING/CONTROLS *SYSTEM 1 USED FOR 2-PIPE DIMENSIONS 12.23 Johnson Controls Unitary Products 5

HORIZONTAL VIEW 30.00 35.00 30.00 60.00 61.09 TYPICAL NH-07, -10, -20 and NJ-10, -20 HORIZONTAL CONFIGURATION 33.00 4 33.00 66.00 67.09 TYPICAL NH/NJ-15 HORIZONTAL CONFIGURATION [ 6 Johnson Controls Unitary Products

PHYSICAL DATA MODEL NH-07 NH-10 NJ-10 NH-15 NJ-15 NH-20 NJ-20 DIMENSIONS (inches) Length 56.0 56.0 56.0 74.5 74.5 98.5 98.5 Width 30.0 30.0 30.0 33.0 33.0 30.0 30.0 Height 65.0 65.0 65.0 75.0 75.0 65.0 65.0 SYSTEM DATA No. Refrigeration Circuits 1 1 2 1 2 1 2 Suction Line OD (in.) 1 1/8 1 3/8 1 1/8 1 5/8 1 1/8 1 5/8 1 3/8 Liquid Line OD (in.) 5/8 7/8 5/8 7/8 5/8 7/8 7/8 Power Wiring Knockout 1 1 1 1 1 1 1 Control Wiring Knockout 7/8 7/8 7/8 7/8 7/8 7/8 7/8 Electric Heat Wiring Knockout 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 Drain Line Fitting PVC Stub 3/4 3/4 3/4 3/4 3/4 3/4 3/4 BLOWER OUTLET Number 1 1 1 1 1 2 2 Width 13.4 15.9 15.9 18.9 18.9 15.9 15.9 Length 15.6 18.6 18.6 21.6 21.6 18.6 18.6 RETURN AIR INLET Width 20.3 20.3 20.3 27.3 27.3 20.3 20.3 Length 53.4 53.4 53.4 71.9 71.9 95.9 95.9 Minimum Clearances Top with Supply Air Opening 1 24 Front with Return Air Opening 24 Right Side with access for Piping, Power & Control Wiring Connections 2 24 Left Side 24 Rear 3 N/A Bottom 4 N/A 1. This dimension will vary if an electric heater, a supply air plenum or a base is used. 2. This dimension is required for normal installation and service. 3. Although no clearance is required for service and operation, some clearance may be required for routing the power and control wiring. 4. Allow enough clearance to trap the condensate drain line. Note: If the coil has to be removed, the blower section can be unbolted and set aside and the coil can be lifted out the top of the evaporator section. FIELD-INSTALLED ACCESSORIES STEAM COIL MODEL...................................... Steam Pressure........................ PSIG Capacity.............................. MBH Steam Rate............................ LBS/HR Entering Air Temperature................. F ELECTRIC HEAT.......................... KW HOT WATER COIL........................................ Capacity.............................. MBH Entering Water Temperature............... F Water Flow Rate........................ GPM Entering Air Temperature................. F Water Pressure Drop.................... PSI * Units with electric heat have a single source power supply. Refer to PRODUCT DATA on front side for electrical data. FACTORY-INSTALLED OPTIONS TECHNICOATED COIL..................................... NOTES: Johnson Controls Unitary Products 7

Subject to change without notice. Printed in U.S.A. Copyright 2009 by Johnson Controls, Inc. All rights reserved. 506447-CSD-A-0209 Supersedes: Nothing Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069