Air Conditioning. Technical Data EEDEN AZQS-BV1

Similar documents
Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

Air Conditioning. Technical Data EEDEN RXS-F8

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

Air Conditioners Technical Data

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

Heating. Technical Data EEDEN ERRQ-AY1

Air Conditioners Technical Data

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F

Air Conditioners Technical Data

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

Air Conditioners Technical Data

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXG-JW

Air Conditioning. Technical Data. 4-way blow ceiling mounted cassette EEDEN ACQ-C

Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB

Air Conditioners. Technical Data RZQG-L

Air Conditioners Technical Data

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K

Air Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C

Air Conditioners Heating & Cooling

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Air Conditioning. Technical Data. Low temperature hydrobox for VRV EEDEN HXY-A

Pure comfort & design

Air Conditioning. Technical Data. Small concealed ceiling unit EEDEN FDBQ-B

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3

Pure comfort & design

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

Air Conditioning Technical Data RZAG-MV1

Air Conditioners Heating & Cooling

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air conditioners Heating & Cooling

Air Conditioning Technical Data RZASG-MV1

Pure comfort & design

Air conditioners Heating & Cooling

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

Daikin Sensira. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Fan Coil Units. Technical Data FWC-BT/BF

where innovation meets creativity

Air conditioners, heating & cooling for the retailmarket and offices

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air Purifiers. Technical Data MC70L

Air Conditioners Heating & Cooling

Air Conditioners. Technical Data FTY-H

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

Daikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

Air Conditioners Heating & Cooling

Daikin leads the way:

Pure comfort & design

Remote control infrared ARC433B76 ARC433A8 ARC433B69

Air Conditioners Heating & Cooling

Air conditioners Heating & Cooling

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

EWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor

Air Conditioners Heating & Cooling

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

Air Conditioning Technical Data AZAS-MY1

Air Conditioning. Technical Data. VRV IV S-series heat pump EEDEN16-200_2 RXYSQ-TV1

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

Air Conditioners Heating & Cooling

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

Air conditioners Heating & Cooling

DAIKIN Air Handling Unit Modular

Air Conditioners. Technical Data FTXS-G

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

VZ Chiller series. Water cooled inverter chiller. The highest peak in chiller technology

Air conditioners, heating & cooling for shops,restaurants and offices

for your home FLXS-B Flexi type unit air to air heat pumps

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB

Air conditioners Heating & Cooling

Our mission: beating the winter cold

emura Form. function. redefined.

w w w. d a i k i n. e u ATXS-E

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

Concealed ceiling units

AIR CONDITIONERS, HEATING & COOLING for your home

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

EWAD-TZB. Screw inverter chiller. High efficiency chiller for comfort and process cooling

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN ABQ-B

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CW1

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN ABQ-A

Air Conditioning. Technical Data. VRV IV S-series compact heat pump EEDEN RXYSCQ-TV1

Air conditioners Cooling only

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

for small rooms in multi application

EEDEN technical data ERHQ AA

Daikin air conditioners for your home, shops, restaurants and offices

EWAT-B. Multi scroll chiller with R-32 refrigerant. First air cooled chiller with environmental friendly R-32 refrigerant

High temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water

DAIKIN EMURA. FORM. FUNCTION. REDEFINED. THE NEW INDOOR AIR CONDITIONING UNIT FROM DAIKIN.

Transcription:

Air Conditioning Technical Data EEDEN14-131 AZQS-BV1

TABLE OF CONTENTS AZQS-BV1 1 Features............................................................. 2 2 Specifications....................................................... 3 Nominal Capacity And Nominal Input................................ 3 Nominal Capacity And Nominal Input................................ 3 Nominal Capacity And Nominal Input................................ 3 Nominal Capacity And Nominal Input................................ 4 Technical Specifications............................................. 4 Electrical Specifications.............................................. 6 3 Electrical data....................................................... 7 4 Options.............................................................. 8 5 Combination table.................................................. 9 6 Capacity tables.................................................... 10 Cooling Capacity Tables............................................ 10 Heating Capacity Tables............................................ 14 Capacity Correction Factor.......................................... 18 7 Dimensional drawings............................................ 19 8 Centre of gravity................................................... 21 9 Piping diagrams................................................... 23 10 Wiring diagrams................................................... 24 Wiring Diagrams - Single Phase................................... 24 11 Sound data......................................................... 26 Sound Power Spectrum............................................. 26 Sound Pressure Spectrum - Cooling................................ 27 Sound Pressure Spectrum - Heating................................ 28 Sound Pressure Spectrum Quiet Mode............................. 29 12 Installation.......................................................... 30 Installation Method.................................................. 30 13 Operation range................................................... 32 Split - Sky Air AZQS-BV1 1

k i n - r o t o - i d l t p uz 1 Features Outdoor Unit AZQS-BV1 S U 1 V B S Q O AS Daikin outdoor units are neat, sturdy and can easily be mounted on a roof or terrace or simply placed against an outside wall Outdoor units are fitted with either a swing or scroll compressor, renowned for low noise and high energy efficiency Outdoor units for pair application Seasonal efficiency, optimized for all seasons. Seasonal efficiency gives an indication on how efficient an air conditioner operates over an entire heating or cooling season. 1 Inverter Auto coolingheating changeover 2 Split - Sky Air AZQS-BV1

2 Specifications Outdoor Unit AZQS-BV1 2-1 Nominal Capacity And Nominal Input *ACQ71C/AZQS71BV1 ACQ100C/AZQS100BV1 ACQ125C/AZQS125BV1 Cooling capacity Nom. kw 6.8 9.5 12.1 Heating capacity Nom. kw 7.50 10.80 13.5 Seasonal efficiency Cooling Energy label B B - (according to Pdesign kw 6.33 9.50 - EN14825) SEER 4.65 4.65 - Annual energy consumption kwh 476 716 - Heating (Average Energy label A A - climate) Pdesign kw 6.33 7.60 - SCOP 3.80 3.80 - Annual energy consumption kwh 2,332 2,800 - Nominal efficiency EER 3.31 3.21 3.01 (cooling at 35 /27 COP 3.61 3.61 3.41 nominal load, heating Annual energy consumption kwh 1,027 1,480 2,010 at 7 /20 nominal load) Energy label Cooling A A B Heating A A B 3 2 Notes (1) EER/COP according to Eurovent 2012 2-2 Nominal Capacity And Nominal Input ABQ71B/AZQS71BV1 Cooling capacity Nom. kw 6.8 (3) Heating capacity Nom. kw 7.5 (4) Seasonal efficiency Cooling Energy label B (according to Pdesign kw 6.80 EN14825) SEER 4.65 Annual energy consumption kwh 512 Heating (Average Energy label A climate) Pdesign kw 6.33 SCOP 3.41 Annual energy consumption kwh 2,599 Nominal efficiency EER 3.01 (cooling at 35 /27 COP 3.61 nominal load, heating Annual energy consumption kwh 1,130 at 7 /20 nominal load) Energy label Cooling B Heating A Notes (1) EER/COP according to Eurovent 2012 2-3 Nominal Capacity And Nominal Input ABQ125A/AZQS125BV1 ABQ140A/AZQS140BV1 Cooling capacity Nom. kw 12.1 13.0 Heating capacity Nom. kw 13.5 15.5 Seasonal efficiency Cooling Energy label - (according to Pdesign kw - EN14825) SEER - Annual energy consumption kwh - Heating (Average Energy label - climate) Pdesign kw - SCOP - Annual energy consumption kwh - Split - Sky Air AZQS-BV1 3

2 Specifications Outdoor Unit AZQS-BV1 2 2-3 Nominal Capacity And Nominal Input ABQ125A/AZQS125BV1 ABQ140A/AZQS140BV1 Nominal efficiency (cooling at 35 /27 nominal load, heating at 7 /20 nominal load) Notes EER 2.91 3.01 COP 3.41 Annual energy consumption kwh 2,079 2,159 Energy label Cooling C B Heating B (1) EER/COP according to Eurovent 2012 2-4 Nominal Capacity And Nominal Input AHQ71C/AZQS71BV1 AHQ100C/AZQS100BV1 AHQ125C/AZQS125BV1 AHQ140C/AZQS140BV1 Cooling capacity Nom. kw 6.8 9.5 12.1 13.0 Heating capacity Nom. kw 7.5 10.8 13.5 15.5 Seasonal efficiency Cooling Energy label B - (according to Pdesign kw 6.80 9.50 - EN14825) SEER 4.65 4.60 - Annual energy consumption kwh 511 723 - Heating (Average Energy label A - climate) Pdesign kw 6.33 7.60 - SCOP 3.80 - Annual energy consumption kwh 2,332 2,800 - Nominal efficiency EER 3.03 2.62 2.63 3.01 (cooling at 35 /27 COP 3.05 3.41 3.61 3.41 nominal load, heating Annual energy consumption kwh 1,120 1,810 2,300 2,159 at 7 /20 nominal load) Energy label Cooling B D B Heating D B A B Notes (1) EER/COP according to Eurovent 2012 2-5 Technical Specifications AZQS71BV1 AZQS100BV1 AZQS125BV1 AZQS140BV1 Capacity control Method Inverter controlled Casing Colour - Ivory white Material - Painted galvanized steel plate Dimensions Unit Height mm 770 990 1,430 Width mm 900 940 Depth mm 320 Packed unit Height mm 900 1,170 1,610 Width mm 980 1,015 Depth mm 420 422 Weight Unit kg 67 81 102 Packed unit kg 71 88 108 Heat exchanger Length mm 857 - Rows Quantity 2 - Fin pitch mm 1.4 - Passes Quantity 8 - Face area m² 0.641 - Stages Quantity 34 - Empty tubeplate Quantity 0 - hole Tube type Hi-XSS (8) - Fin Type WF fin Treatment Anti-corrosion treatment (PE) 4 Split - Sky Air AZQS-BV1

2 Specifications Outdoor Unit AZQS-BV1 2-5 Technical Specifications AZQS71BV1 AZQS100BV1 AZQS125BV1 AZQS140BV1 Compressor Quantity 1 Model 2YC63DXD - Type Hermetically sealed swing compressor Output W 1,700.0 - Starting method Inverter driven - Fan Type Propeller fan Discharge direction Horizontal Quantity 1 2 Air flow rate Cooling Nom. m³/min 52.0 76 77 83 Super m³/min - low cfm - Heating Nom. m³/min 48.0 83 62 Super m³/min - low cfm - Fan motor Quantity 1 2 Model KFD-325-70-8A Brushless DC motor Output W 70 200 94 Drive Direct drive Speed Steps 8 - Cooling Nom. rpm 800 - Super low rpm - Heating Nom. rpm 745 - Super low rpm - Sound power level Cooling Nom. dba 64 70 71 70 Sound pressure level Cooling Nom. dba 48 53 54 53 Silent operation dba 43 - Heating Nom. dba 50 57 58 54 Night quiet mode Level 1 dba - 49 Operation range Cooling Ambien Min. CDB -5.0 t Max. CDB 46.0 Heating Ambien Min. CWB -15.0 t Max. CWB 15.5 Refrigerant Type R-410A Charge kg 2.75 2.9 4.0 Control Expansion valve (electronic type) GWP 1,975 Circuits Quantity 1 Refrigerant oil Type FVC50K Charged volume l 0.75 0.9 1.35 3 2 Split - Sky Air AZQS-BV1 5

2 Specifications Outdoor Unit AZQS-BV1 2 2-5 Technical Specifications AZQS71BV1 AZQS100BV1 AZQS125BV1 AZQS140BV1 Piping connections Liquid Quantity 1 Type Flare connection OD mm 9.52 Gas Quantity 1 Type Flare connection OD mm 15.9 Drain Quantity 3 5 Type Hole ID mm - OD mm 26 Piping length OU - IU Min. m 5 Max. m 30 50 System Equival ent m 40 70 Chargel ess m 30 Additional refrigerant charge kg/m See installation manual Level difference IU - OU Max. m 15.0 30.0 IU - IU Max. m - 0.5 Heat insulation Both liquid and gas pipes Defrost method Pressure equalising Reversed cycle Defrost control Sensor for outdoor heat exchanger temperature Safety devices Item 01 High pressure switch 02 Fan motor thermal protection 03 Fuse 2-6 Electrical Specifications AZQS71BV1 AZQS100BV1 AZQS125BV1 AZQS140BV1 Power supply Name V1 Phase 1~ Frequency Hz 50 Voltage V 220-240 Voltage range Min. % -10 Max. % 10 Current Nominal running Cooling A 16.20 - current (RLA) Zmax List Complies to EN6100-3- Complies to EN61000-3-12 3 Recommended fuses A 20 32 Current - 50Hz Maximum fuse amps (MFA) A 20 - Current - 60Hz Maximum fuse amps (MFA) A - Wiring connections For power supply Remark - See installation manual outdoor unit For connection with Remark - See installation manual outdoor unit indoor Power supply intake Outdoor unit only Notes (1) See separate drawings for electrical data (2) Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current \>16A and 75A per phase (3) PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (4) European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and 75A per phase. (5) Short-circuit power (6) RLA is based on following conditions: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB (7) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). 6 Split - Sky Air AZQS-BV1

3 Electrical data 3-1 Electrical Data Outdoor Unit AZQS-BV1 3 3 Split - Sky Air AZQS-BV1 7

4 Options 4-1 Options Outdoor Unit AZQS-BV1 4 8 Split - Sky Air AZQS-BV1

5 Combination table 5-1 Combination Table Outdoor Unit AZQS-BV1 3 5 Split - Sky Air AZQS-BV1 9

6 Capacity tables 6-1 Cooling Capacity Tables 6 10 Split - Sky Air AZQS-BV1

6 Capacity tables 6-1 Cooling Capacity Tables 3 6 Split - Sky Air AZQS-BV1 11

6 Capacity tables 6-1 Cooling Capacity Tables 6 12 Split - Sky Air AZQS-BV1

6 Capacity tables 6-1 Cooling Capacity Tables 3 6 Split - Sky Air AZQS-BV1 13

6 Capacity tables 6-2 Heating Capacity Tables 6 14 Split - Sky Air AZQS-BV1

6 Capacity tables 6-2 Heating Capacity Tables 3 6 Split - Sky Air AZQS-BV1 15

6 Capacity tables 6-2 Heating Capacity Tables 6 16 Split - Sky Air AZQS-BV1

6 Capacity tables 6-2 Heating Capacity Tables 3 6 Split - Sky Air AZQS-BV1 17

6 Capacity tables 6-3 Capacity Correction Factor 6 18 Split - Sky Air AZQS-BV1

7 Dimensional drawings 7-1 Dimensional Drawings 3 7 Split - Sky Air AZQS-BV1 19

7 Dimensional drawings 7-1 Dimensional Drawings 7 20 Split - Sky Air AZQS-BV1

8 Centre of gravity 8-1 Centre of Gravity Outdoor Unit AZQS-BV1 3 8 Split - Sky Air AZQS-BV1 21

8 Centre of gravity 8-1 Centre of Gravity Outdoor Unit AZQS-BV1 8 22 Split - Sky Air AZQS-BV1

9 Piping diagrams 9-1 Piping Diagrams Outdoor Unit AZQS-BV1 3 9 Split - Sky Air AZQS-BV1 23

10 Wiring diagrams 10-1 Wiring Diagrams - Single Phase 10 24 Split - Sky Air AZQS-BV1

10 Wiring diagrams 10-1 Wiring Diagrams - Single Phase 3 10 Split - Sky Air AZQS-BV1 25

11 Sound data 11-1 Sound Power Spectrum 11 26 Split - Sky Air AZQS-BV1

11 Sound data 11-2 Sound Pressure Spectrum - Cooling 3 11 Split - Sky Air AZQS-BV1 27

11 Sound data 11-3 Sound Pressure Spectrum - Heating 11 28 Split - Sky Air AZQS-BV1

11 Sound data 11-4 Sound Pressure Spectrum Quiet Mode 3 11 Split - Sky Air AZQS-BV1 29

12 Installation 12-1 Installation Method Outdoor Unit AZQS-BV1 12 30 Split - Sky Air AZQS-BV1

12 Installation 12-1 Installation Method Outdoor Unit AZQS-BV1 3 12 Split - Sky Air AZQS-BV1 31

13 Operation range 13-1 Operation Range Outdoor Unit AZQS-BV1 AZQS-BV1 (Cooling) 13 Outdoor temp. ( CDB) Operation range Allowable range of operation (pull-down) Outdoor temp. ( CWB) Allowable range of operation (warming-up) (Heating) Operation range Indoor temp. ( CWB) Indoor temp. ( CDB) Notes: 1 Depending on operation and installation conditions, the indoor unit can change over to freeze-up operation (indoor de-icing). 2 To reduce the freeze-up operation (indoor de-icing) frequency, it is recommended to install the outdoor unit in a location not exposed to wind. 3 In case of high humidity conditions (>92%) in this operation area, an RZQG model should be used instead of an RZQSG model. This to avoid freeze-up of the outdoor unit. 3D076504 32 Split - Sky Air AZQS-BV1

Daikin Europe N.V. participates in the Eurovent Certification programme for Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. BARCODE Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende EEDEN14-131 12/13 Copyright Daikin The present publication supersedes EEDEN13-131