Montrose House Lancaster Road Cressex Business Park High Wycombe Buckinghamshire HP12 3PY Contact: Mr D McKenna Tel:+ 44 (0)1494 452713 E-Mail: david.mckenna@buildcheck.co.uk Website: www.buildcheck.co.uk oratory locations: below s covered by the organisation and their relevant activities details Activity code Address Unit 3 Lincoln Business Centre Lincoln Road High Wycombe Bucks HP12 3RD United Kingdom Local contact Mr D McKenna Thermal transmittance (U value) by calculation Calculations of heat flows & temperatures in thermal bridges Weather tightness tests Window and door security tests Smoke control tests activities performed away from the locations listed above: details Activity code At any suitable customer premises Building air leakage test Sound insulation tests including precompletion testing for dwellings and rooms for residential purpose for The Building Regulations 2010. Approved Document E (2003 Edition incorporating 2004, 2010, 2013 and 2015 amendments). Assessment Manager: PJ1 Page 1 of 6
DETAIL OF ACCREDITATION ACOUSTICS Buildings - elements such as partitions, walls, floors, Field of airborne sound insulation, ie Level Difference and related factors Sound insulation tests including pre-completion testing for dwellings and rooms for residential purpose for The Building Regulations 2010. Approved Document E (2003 Edition incorporating 2004, 2010, 2013 and 2015 amendments). Buildings - floors Field of impact sound insulation of floors between rooms, ie Impact Sound Pressure Level and related factors Sound insulation tests including pre-completion testing for dwellings and rooms for residential purpose for The Building Regulations 2010. Approved Document E (2003 Edition incorporating 2004, 2010, 2013 and 2015 amendments). BUILDINGS Physical Tests Building Air Leakage Test BS EN 13829:2001 ATTMA Technical Standard 1:2006 ATTMA TSL1:2010 ATTMA TSL2:2010 ATTMA TSL1:2016 DOORS, WINDOWS, SHUTTERS and GLAZING PRODUCTS Thermal transmittance (U-value) BS EN ISO 10077-1:2006 BS EN ISO 10077-2:2012 BS EN 673:2011 Annex J Calculations of heat flows & temperatures in thermal bridges EN ISO 10211-1:1995 EN ISO 10211-2:1995 Determination of sound insulation of windows Annex B Assessment Manager: PJ1 Page 2 of 6
WINDOWS and DOORS Air permeability BS EN 1026:2016 Watertightness BS EN 1027:2000 BS EN 1027: 2016 Resistance to wind load BS EN 12211:2016 Weathertightness BS 6375-1:2015 WINDOWS Operating forces BS 6375-2:2009 BS EN 12046-1:2003 Static torsion BS 6375-2:2009 BS EN 14609:2004 Racking BS 6375-2:2009 BS EN 14608:2004 Soft and heavy body impact BS 6375-2:2009 BS EN 13049:2003 Load bearing capacity of safety devices BS 6375-2:2009 BS EN 14609:2004 As modified by in-house procedure TP09 DOORS Operating forces BS 6375-2:2009 BS EN 12046-2:2000 BS EN 12217:2003 Vertical load BS 6375-2:2009 BS EN 947:1999 Static torsion BS 6375-2:2009 BS EN 948:1999 Soft and heavy body impact BS 6375-2:2009 BS EN 13049:2003 BS EN 949:1999 Assessment Manager: PJ1 Page 3 of 6
DOORS (cont d) Hard body impact BS 6375-2:2009 BS EN 950:1999 Load bearing capacity of safety devices BS 6375-2:2009 BS EN 948:1999 as modified by Documented In-House Method No TP09 DOOR AND SHUTTER ASSEMBLIES Smoke control BS EN 1634-3:2004 (ambient temperature test only) EXTERNAL DOORSETS - single and double leaf - single swing - hinged - sliding - folding sliding - inward and outward opening - with or without integral side panels and fanlights - manual test - mechanical test Manual cutting test Soft body impact test Hard body impact test Security hardware and cylinder test - Part 1 - Part 2 PAS 24:2012 Letter plate fixings BS EN 13724:2002 Clause 6.6.5.1 (withdrawn) as modified by PAS 24:2012 Assessment Manager: PJ1 Page 4 of 6
WINDOWS: SINGULAR and MULTILIGHT - top hung (open out), side hung (open in and open out), bottom hung (open in), butt hinged - top and side hung (open out), projected - top hung fully reversible - tilt and turn and turn and tilt - vertical sliding - fixed and dummy vents - double opening (French windows) - manual test - mechanical test PAS 24:2012 DOORSETS - single and double leaf - single and double swing - hinged - sliding (single and multitrack) - pivot - folding sliding (single and multi-track) - stable - with or without integral side panels and fanlights - manual test - mechanical test Manual cutting test Soft body impact test Hard body impact test Security hardware and cylinder test - Part 1 & Part 2 PAS 24:2016 WINDOWS: SINGULAR and MULTILIGHT - top hung, side hung, bottom hung, butt hinged - top and side hung projected - top hung and side hung fully reversible - tilt and turn and turn and tilt - vertical and horizontal sliding - fixed and fixed casements (dummy vents) - parallel opening - double opening (French windows) - vertical and horizontal pivot - manual test - mechanical test PAS 24:2016 END Assessment Manager: PJ1 Page 5 of 6
Accreditation for the purpose of Notified Body activity taking into account EA 2/17 Directive / Regulation Conformity Assessment Procedure / Module / Article Category of Products or Individual Products Essential Requirements: Product Specification / Properties / Standards The Construction Products Regulation (EU) No 305/2011 Annex V - Testing oratory (AVCP) System 3 99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) : - Windows (with or without related hardware) (any other) EN 14351-1:2006+A1:2010 Annex V - Testing oratory (AVCP) System 3 99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) : - Doors and gates (with or without related hardware) (other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes). EN 14351-1:2006+A1:2010 END Assessment Manager: PJ1 Page 6 of 6