LIFECARE PLV-100. by Bryce Younger

Similar documents
Achieva. Ve nt i l at or with Flow Acceleration Limit and Apnea Backup. User s Manual

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

Servo i. CRC 335 University of South Alabama Cardiorespiratory Care

Oxylog 2000 plus Pocket Guide Software version 1.n

NIPPY junior+ Quick Reference Guide

PRODUCT SPECIFICATIONS VENTILATOR Aeros-4600

O-Two Self-Study Guide. eseries Transport Ventilator Control and Function Keys and Connections

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

CLINICAL MANUAL REF JH 6/7/10 CLINICAL MANUAL

SPECIFICATION FOR MULTIPARAMETER MONITOR

Oxylog VE300 Emergency & Transport Ventilation

Quick start guide. English

Quick setup guide. English

Oxylog VE300 Emergency & Transport Ventilation

Oxylog VE300 Emergency & Transport Ventilation

USER Manual JR 10/02/06

Checkout Procedure Manual

INSTRUCTION MANUAL FOR THE NIPPY 3+ POSITIVE PRESSURE VENTILATOR This book must be kept with the machine

INSTRUCTION MANUAL FOR THE NIPPY 3+ POSITIVE PRESSURE VENTILATOR This book must be kept with the machine

Cost-effective way to tailor anesthesia

INSTRUCTION MANUAL FOR THE NIPPY JUNIOR PAEDIATRIC VENTILATOR

Quick start guide. BiPAP AVAPS

End-Tidal CO2 User Guide CAPNO3 T NIBP. SpO2. Ver Charmcare Co., Ltd.

SPT & PRO PROVIDER MATERIALS

4L & PRO PROVIDER MATERIALS

5580 S. Nogales Highway Tucson, AZ Phone: (800) Fax: (520) ANAPOD Instructions For Use

How to use Medi-Therm III hyper/hypothermia system

Adjusting the Pulse Flow Setting

RQE Series Temperature Controllers

CARAT II. User's Manual Ventilator. as of device software Quality makes the Difference

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

User guide User guide English

4. ALIGNMENT AND ADJUSTMENTS

Neonatal Ventilator NV8

Puritan Bennett 980 Ventilator System Planning for Training Checklist

Cl inician Training Packet

Vitalmax 4000 CL Product Specifications

7-Day Electronic Timer Model CDN Operating Instructions

Quick start guide. BiPAP AVAPS

User guide User guide English

TX6831 Data Sheet. Features. Benefits

Humidification & Filtration

K9 Heat Alarm Owners Manual HA-1520

P1195 DUAL TOURNIQUET MONITOR

Operating Functions Temperature Parameters

SOFTWARE VERSION 8.5 FAQs

Theory of Operation: M9/D & M11/D

NQ Series Portable Chillers

MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual

OWNERS MANUAL MODEL 451 (-101 & -201)

Document No

Carina Guidelines. The Carina Guidelines are not a replacement or substitute for the Instructions for Use.

PYROSELF Innovative Snow Sensor and Controller for 2 x 24A loads outputs. Installation and Operating manual

Operating Manual for the Impact-III Veterinary MultiMonitor from Vetronic Services

ACC RADIO CONTROL SYSTEM. Rev A 12/23/14

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

CONTENTS. III. OPERATING INSTRUCTIONS... pg 7 LOADING DISPOSABLE SET (Figure 4)... pg 9. IV. INDICATORS AND ALARMS... pg 10

AT10.1 Series Microprocessor-Controlled Float Battery Charger (single phase input)

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

NexSysLink. 2 CAN Display Operation Manual. CAN Instruments Product Family

NOTE: Key can be programmed to unlock driver's door only, using the following procedure:

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

WIRING DIAGRAM. This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900

Smoke & Carbon Monoxide Alarms

SFC-200 SERIES LED FIRE ALARM PANEL

Fast Track Troubleshooting

Mobile climate solutions

Professional Operator s Manual

MODEL MW200 MODEL MW600 AIR DRYER

INSTRUCTIONS FOR CONTINUED AIRWORTHINESS

FDF Foam Pump Controllers Features

Adult and paediatric ventilators. Quick Setup Guide. English

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

LEONI baby ventilator service manual

Restek s Electronic Leak Detector

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER

Patient/Family Education Teaching Protocol HeartMate II Left Ventricular Assist System

Important user information

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

USER MANUAL PORTABLE OXYGEN CONCENTRATOR SAVE THESE INSTRUCTIONS

Instruction manual. W440 AIS Sart Sniffer

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

Service Manual. Infant Flow SiPAP. Model M675. Copyright 2005, VIASYS Healthcare Respiratory Care

AFA 500 FUME HOOD ALARMS

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS

Mobile climate solutions

CG Series Digital Temperature Controller OPERATIONS MANUAL

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

Suction Pump F-30.xx

DC200 Digital Dispenser Operating Manual

HUG.ai 1/24/06 9:33:34 AM HUG.ai 1/24/06 9:33:34 AM C M Y CM MY CY CMY K

ConchaTherm Neptune Heated Humidifier User s Manual /07 English (EN)

VA301C CONTROLLER WITH BACnet OPTION

Warmette Blanket Cabinet Warmette Dual Cabinet. User Manual

ELECTRONIC GUN SAFE USER MANUAL. Models: SLSFE61GN - SLSFE63GN

CONTENTS Introduction and Characteristics. 1 Fire Alarm System Assembly Diagram.. 2 Fire Alarm Signal Flow Chart.. 2 Panel Descriptions 3 Standard

Brivis Service Manual

C2 Compact Range Installation & Programming Manual

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

Transcription:

LIFECARE PLV-100 by Bryce Younger 1

Classification Electrically powered microprocessor controlled Volume-control, time cycled Rotary drive piston Modes Modes Control A/C SIMV 2

Modes Control Assist/Control SIMV - machine "looks" for a patient inspiratory effort 6 seconds before the next scheduled mandatory breath. Tidal Volume - LED display volume setting 50-3000 ml. 3

Controls Rate - LED display set rate 2-30 BPM. I:E Ratio display Flashes if inverse Ratio is set. Flowrate - LED display of flowrate 10-120 LPM. Flashes when insufficient. Sensitivity Less or more 4

Controls (cont.) Airway Pressure Limit (10-100 cm/h2o) Vents excess pressure and sounds audible alarm simultaneously. Inspiration ends. Flow Rate LED window. Power Switch (ON/OFF/RECHARGE) Internal and external battery will be charged as long as line cord is plugged into wall outlet, regardless of switch position. 5

Alarms Low Pressure (2-50 cm/h2o) Delayed audible alarm activated when proximal airway pressure falls below low pressure alarm setting. Green LED lamp lights immediately when proximal airway pressure falls below alarm setting (audible delayed 15 seconds in A/C and SIMV modes. In SIMV mode, if proximal airway pressure does not exceed Low Pressure setting during a machine breath, audible alarm activated immediately at the end of the machine breath. Serves as disconnect alarm). Apnea Alarm same as Low Pressure in SIMV during machine breath. Power Failure Audible alarm when "ON" and no power applied. 6

Alarms (cont.) Microprocessor Failure Machine monitored internally and locks motor out if failure conditions sensed. Patient able to breathe through machine. During ventilator malfunctions (Pressure transducer failure and piston system failure), an audible "fast beep" alarm will sound. 7

Alarms (cont.) Low Internal Battery If voltage of internal battery falls below 9.5 volts, audible alarm sounds and "Internal Battery" lamp will flash on and off. Low External Battery same as for internal battery. "External Battery" lamp will flash on and off. Reverse External Battery Connection If battery leads reversed on external battery connection, an audible alarm will sound (even in OFF position) until the external battery is disconnected. No damage will occur to the unit or external battery. Switch to Battery When power source switches automatically to internal or external battery, a 3 second audible alarm will sound to alert the operator that limited operation time remains. 8

Front Panel Increase Inspiratory Flow Red indicator lamp flashes when set inspiratory flow is insufficient to meet other set parameters. Machine will increase flow over set value and flash red light. AC Power Source Green indicator light Internal DC Power Source Amber indicator light External DC Power Source 9

Assist/Spontaneous LED Green indicator light indicates an assisted breath in A/C mode and indicates spontaneous breaths in SIMV mode. Assisted and Spontaneous breaths will register on the BPM Display. 10

Front Panel (cont.) Patient BPM Digital Display In Control mode, indicates BPM set. In Assist/Control mode displays total number of breaths. In SIMV mode displays total number of machine and spontaneous breaths. Updated every 4 breaths or whenever rate knob changed. I:E Ratio Digital Display - blinks during inverse ratio or readings over 1: 9.99 (Off during SIMV). Inspiratory Flow Rate Digital Display - displays peak 11

Tidal Volume Digital Display - displays tidal volume set. Pressure Gauge - displays pressure at proximal airway. 12

On Start-Up Diagnostic Check On Start-Up When PLV turned on, performs 5 second self check. During check Digital read 88's Vt displays 0.0 (in case of pressure transducer failure, Vt displays 1.0). If test detects error, 2.0 will be displayed in Vt display and audible alarm sounds - Do Not Use. 13