Rittal roof-mounted fans

Similar documents
Rittal roof-mounted fans Efficiency on top

Energy Efficient Enclosure Climate Control

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

ClimaSys Resistance heaters Selection guide

Life insurance for your electronics

Power Isolation Solutions. Arc Flash Prevention Starts Here

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection

Protection for the Industry that Powers the Planet

316 Stainless Steel TS 8 Enclosure. The most rugged TS 8 yet

Extreme industrial environments Air/water heat exchangers (roof-mounted, wall-mounted) Recooling system

electronics Protection

Scha tschra Hei u g E c sure heater R sista ces chauffa tes Scha e astverwar i ge. Risca dat re a tic de sa Resiste cia ca efact ra 3105 XXX

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

Eldon Product Overview

Everyone talks about the future, but Rittal helps shape it and that includes. Modern cooling units with excellent efficiency and perfect interface

Optimise wire processing A comprehensive range of products for the workshop

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Interface and EOL Modules 8

WHITE PAPER: Cooling Industrial Enclosures with Filter Fans

SELECTION GUIDE. Industrial Thermoregulation. Products for panels and enclosures

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

Product Management, Rev 3 December 2009

Thermal control. Overview. Adjustable thermostats. Double-adjustable thermostat. Different installation methods. The new quick-fixing systems:

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Food & Beverage Buyer s Guide

Cooling unit Mechanical control

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities.

More Precision. thicknesssensor // The sensor for precise thickness measurements

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Thermal Management Products & Accessories for Enclosures

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue

Thermal management for your cabinets!

Heaters, Thermostats and Hygrostats

Power. Average noise level (DIN EN ISO 4871)

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

USER GUIDE. RLH Auxiliary Fan Kit. Description. The leader in rugged fiber optic technology. ENCLOSURE TEMPERATURE CONTROL. RLH Industries, Inc.

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Control solutions Biofloor

Climate Control Quick Reference

Stego accessories for cabinets

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs

CMD420 / CMD421 Series

Frequently asked questions: Intelligent Transmitter Series

OEM Alpha Thermostat direct Analog

Thermostats. Innovative solutions for the toughest requirements

NEW GENERATION. Efficient use of valuable space INCUBATORS

Safe Enclosure Cooling

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

SIVACON sicube 8MF system cubicles 16/2 Introduction 16/3 8MF system cubicles 16/4 Preconfigured cubicles

Bulletin 1608N MiniDySC Dynamic Sag Corrector

Recalibrate the way you look at gas detection

Enclosure Heaters and Fan Heaters

Enclosure cooling unit

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Betriebsanleitung / Operation manual. Druckwächtereinheit QUINGUARD / Pressurization Controller QUINGUARD

RE-PR3-E-27 3-Phase Panel Mount 27kW

WHITE PAPER: Thermal Management Solutions

Product data sheet AIRWIN additional modules Accessories AIRWIN

EXPELS MORE AIR FROM AN ENCLOSURE

1.7. Insulation fault evaluators EDS460/490 EDS461/491

COOL COMBINATION EQUIPMENT PROTECTION SOLUTIONS INDUSTRIAL ENVIRONMENTS

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

Loadstar AC/DC Systems

Air Shower TECHNICAL DATA

GasGard 100 Control System

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

Engineering Guideline. pac- Carriers Type Universal

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

Product Description. Options. Fan Voltage. Electrical Connections Technical Data - Key Characteristics

Table of Content

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Advantages / Characteristics

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Key-Operated Switch GMA 41 / GMA 44 SW. Operation Manual

Speed and Frequency Seite 1 von 7

Contents. External and internal tight cabinets, heating and cooling systems. IP55 outdoor distribution cabinets 1-4

Washing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan

THERMASREG TR 040 THERMASREG TR 060

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan

LiqTec, V GRUNDFOS INSTRUCTIONS

configurable safety and programmable logic SLATE Integrated Combustion Equipment Management The revolutionary integration of

p u m p s Technology. Innovation. Commitment. M A C E R A T O R E n h a n c e y o u r l i f e

Burner control unit BCU 370

Halyester Totally insulated enclosure system. Degree of protection up to IP66. Product Aid. Multifunctional Enclosure Systems for all Environments

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

On the job around the clock 24/7: Fire detection systems

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

CONVENIENT FEATURES ...MORE PERFORMANCE LESS... SPACE ENERGY NOISE G-TEC BELT-DRIVEN ROTARY SCREW AIR STATION. 7.5 to 22 kw 8 to 13 bar

for relative humidity and temperature

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

CR 027 PTC Fan Heater W

Transcription:

Rittal roof-mounted fans

2 Climate control/roof-mounted fans

The whole is more than the sum of its parts The same is true of Rittal The System. Keeping this in mind, we have bundled our innovative enclosure, power distribution, climate control and IT infrastructure products together into a single system platform. Complemented by our extensive range of software tools and global service, we create unique added value for trade and industry that include production plants, test equipment, facility management and data centers. In accordance with our simple principle, Faster better everywhere, we are able to optimally combine innovative products and efficient service. Faster with our Rittal The System. range of modular solutions, which guarantees fast planning, assembly, conversion and commissioning with its system compatibility. Better by quickly translating market trends into products. In this way, our innovative strength helps you to secure competitive advantages. Everywhere thanks to global networking: 13 production facilities with almost 250,000 m 2 production space worldwide 58 subsidiaries Around 90 warehouse facilities with more than 180,000 pallet locations and over 260,000 m2 storage space worldwide Climate control/roof-mounted fans 3

Roof-mounted fans One system for all sizes Simply top Just one mounting cut-out for all output categories 9.8 x 10.2 inches (250 x 258 mm) Optimum efficiency, due to sophisticated air routing with minimal pressure losses Innovative clamping attachment maintains ingress protection (IP) ratings 4 Climate control/roof-mounted fans

Climate control/roof-mounted fans 5

6 Climate control/roof-mounted fans

Roof-mounted fans Easy locking with innovative clamping attachment Simple to fit and maintain Innovative clamping attachment allows optional flexible locking from the outside or inside Easy electrical connection via plug terminal Good accessibility permits fast filter mat changes High protection category IP 55 as standard, due to a sophisticated labyrinth system and high-quality foamed-in seal International approvals and easy accessibility Large output range with high efficieny Passive variant without fan for natural convection Air throughput range from 294 589 cfm (500 1,000 m³/h) At an air throughput of 589 cfm (1,000 m³/h), EC fans ensure maximum energy efficiency Climate control/roof-mounted fans 7

Roof-mounted fan, roof vent Accessories for climate control Page 10 Color: RAL 7035 Protection category IP to IEC 60 529: IP 22 without filter mat IP 55 including filter mat Supply includes: Complete unit ready to install, including filter mat Note: For energy-efficient operation of the fans, we recommend the use of thermostats or temperature displays The specified air throughput, unimpeded airflow, is without a filter mat Air throughput 294 512 cfm (500 800 m 3 /h) Model No. Packs of 3138.000 3139.100 3139.110 3140.100 3140.110 3140.140 Rated operating voltage V, ~, Hz - 230, 1~, 50/60 115, 1~, 50/60 230, 1~, 50/60 115, 1~, 50/60 Air throughput, unimpeded air flow cfm (m 3 /h) - 294/323 (500/550) 294/323 (500/550) 471/530 (800/900) 471/518 (800/880) 400, 3~, 50/60 460, 3~, 60 471/512 (800/870) Rated current A - 0.23 / 0.29 0.47 / 0.59 0.45 / 0.6 0.93 / 1.23 0.19 / 0.22 Pre-fuse A - 6 6 6 6 - Motor circuit-breaker A - - - - - 6.3...10 Power consumption W - 52 / 65 53 / 66 102 / 135 105 / 140 98 / 130 Width inches (mm) 15.7 (400) 15.7 (400) 15.7 (400) 15.7 (400) 15.7 (400) 15.7 (400) Height inches (mm) 5.2 (133) 5.2 (133) 5.2 (133) 5.2 (133) 5.2 (133) 5.2 (133) Depth inches (mm) 15.7 (400) 15.7 (400) 15.7 (400) 15.7 (400) 15.7 (400) 15.7 (400) Max. installation depth inches (mm) 1.1 (27) 1.8 (30) 1.8 (30) 1.8 (30) 1.8 (30) 1.8 (30) Required mounting cut-out inches (mm) Fan 10.2 x 10.2 (258 x 258) without fan motor 10.2 x 10.2 (258 x 258) Radial, capacity motor 10.2 x 10.2 (258 x 258) Radial, capacity motor 10.2 x 10.2 (258 x 258) Radial, capacity motor 10.2 x 10.2 (258 x 258) Radial, capacity motor 10.2 x 10.2 (258 x 258) Radial, rotary current motor Operating temperature range F (C) (-30 C...+55 C) (-30 C...+55 C) (30 C...+55 C) (30 C...+55 C) (30 C...+55 C) (30 C...+55 C) Storage temperature range F (C) Accessories -40 F...+150 F (-40 C...+70 C) -40 F...+150 F (-40 C...+70 C) -40 F...+150 F- (40 C...+70 C) -40 F...+150 F (40 C...+70 C) -40 F...+150 F (-40 C...+70 C) -40 F...+150 F (-40 C...+70 C) Outlet filter 1 pc(s). 3243.200 3243.200 3243.200 3243.200 3243.200 3243.200 Spare filter mats 12 pc(s). 3174.100 3174.100 3174.100 3174.100 3174.100 3174.100 307 Enclosure internal thermostat 1 pc(s). - 3110.000 3110.000 3110.000 3110.000 3110.000 315 Digital enclosure internal temperature display and thermostat 1 pc(s). - 3114.200 3114.200 3114.200 3114.200 3114.200 315 Hygrostat 1 pc(s). - 3118.000 3118.000 3118.000 3118.000 3118.000 316 Cat. 34, 308 8 Climate control/roof-mounted fans

Roof-mounted fan, roof vent Accessories for climate control Page 10 Energy-efficient and powerful design of the roof-mounted fans. The fan may be activated via control interface with external temperature-dependent speed control Color: RAL 7035 Protection category IP to IEC 60 529: IP 22 without filter mat IP 55 including filter mat Supply includes: Complete unit ready to install, including filter mat Note: For even more efficient operation or for monitoring the fans, we recommend the use of the EC speed controls The specified air throughput, unimpeded airflow, is without a filter mat Air throughput, unimpeded air flow 589 cfm (1000 m 3 /h), with EC technology Model No. Packs of 3140.500 3140.510 Control interface Rated operating voltage V, ~, Hz 200-240, 1~, 50/60 100-130, 1~, 50/60 Air throughput, unimpeded air flow cfm (m 3 /h) 589 (1000) 589 (1000) Rated current A 1.2 1.9 Pre-fuse A 6 6 Power consumption W 148 125 Width inches (mm) 15.7 (400) 15.7 (400) Height inches (mm) 5.2 (133) 5.2 (133) Depth inches (mm) 15.7 (400) 15.7 (400) Max. installation depth inches (mm) 1.8 (30) 1.8 (30) Required mounting cut-out inches (mm) 10.2 x 10.2 (258 x 258) 10.2 x 10.2 (258 x 258) Fan Radial, EC motor Radial, EC motor Operating temperature range F (C) (-30 C...+55 C) (-30 C...+55 C) Storage temperature range F (C) -40 F...+158 F (-40 C...+70 C) -40 F...+158 F (-40 C...+70 C) Accessories Outlet filter 1 pc(s). 3243.200 3243.200 Spare filter mats 12 pc(s). 3174.100 3174.100 307 EC speed control Cat. 34, 308 1 pc(s). 3235.440 3235.440 316 1 pc(s). 3235.450 3235.450 317 Enclosure internal thermostat 1 pc(s). 3110.000 3110.000 315 Digital enclosure internal temperature display and thermostat 1 pc(s). 3114.200 3114.200 315 Hygrostat 1 pc(s). 3118.000 3118.000 316 Climate control/roof-mounted fans 9

Accessories Spare filter mats Made of chopped-fibre mat with a progressive structure. Temperature-resistant to 100 C, self-extinguishing category F1 to DIN 53 438. Dust laden air side: Open structure. Clean-air side: Closed structure. Reliable filtering of virtually all types of dust from a particle size of 10 μm Design for roof-mounted fans To fit Model No. 3138.../3139.../3140... Material Chemical fibres Width in. (mm) 10.4 (264) Height in. (mm) 3.7 (95) Depth in. (mm) 0.67 (17) Filter class to DIN EN 779 G3 Packs of 12 pc(s) Model No. 3174.100 EC speed control Control unit for EC fan-and-filter units Temperature-dependent speed control for EC fan-and-filter units to reduce noise and save energy. The function of the fan can also be monitored. Functions: Activation and monitoring of up to 4 EC fan-andfilter units For mounting on a 35 mm support rail EN 50 022 External temperature sensor to record the actual temperature Status LED to display the operating status Alarm relay for reporting overtemperature, fan defect, cable break and sensor failure Supply includes: NTC sensor, length 1.80 m To fit Model No. 3240.500/3241.500/ 3243.500/3244.500/ 3245.XXX/3140.500/ 3140.510 Rated operating voltage V 100-250 Setting range 41 F...+131 F +5 C...+55 C Model No. 3235.440 EC speed control Sensor for speed control NTC sensor for temperature-dependent speed control of EC fan-and-filter units to reduce noise and save energy. Activation and power supply via an EC fan-and-filter unit. Technical specifications: Control characteristic: fixed setpoint at 35 C, with linear control range between +35 C (maximum speed 100%) and +20 C (minimum speed 10%) Protection category IP to IEC 60 529: IP 40 Supply includes: External sensor with connection cable (length 3 m) To fit Model No. 3240.500/3241.500/ 3243.500/3244.500/ 3245.XXX/3140.500/ 3140.510 Rated operating voltage V 100-250 Setting range 41 F...+131 F +5 C...+55 C Model No. 3235.440 Digital enclosure internal temperature display and thermostat For installation in the enclosure door or wall. Technical specifications: Three-digit, 7-segment display Option of switching between C/ F Includes 1800 mm long NTC sensor Two relay outputs as change-over contact and normally open contact (max. contact load 230 V, 6 A) Freely selectable switching difference Rated operating voltage V, ~, Hz 100-230, 1~, 50/60 24-60 (DC) Installation depth in (mm) 3.94 (100) Approvals Setting range Operating temperature range UR 41 F...+131 F +5 C...+55 C 41 F...+131 F +5 C...+55 C Model No. 3114.200 10 Climate control/roof-mounted fans

Accessories Enclosure internal thermostat Especially suitable for controlling fan-and-filter units, heaters and heat exchangers, this thermostat can also be used as a signal generator for monitoring the enclosure internal temperature. Benefits: Time-saving connection technique using a terminal strip with a screw connection from the outside. Flexible mounting on a vertical or horizontal 35 mm support rail to EN 50 022, and snap fastening in the TS/SE enclosure section or on the mounting plate using the supplied adaptor Technical specifications: Bi-metal controller as a temperature-sensitive element with thermal feedback. Contact population: Single-pole change-over contact as a quick-break contact. Hygrostat The hygrostat switches on the heater and/or fan when a preset relative humidity in the enclosure is exceeded. In this way, the relative humidity is raised above the dew point, and condensation on assemblies or electronic components is avoided. Benefits: Time-saving connection technique using a terminal strip with a screw connection from the outside. Flexible mounting on a vertical or horizontal 35 mm support rail to EN 50 022, and snap fastening in the TS/SE enclosure section or on the mounting plate using the supplied adaptor Technical specifications: Contact population: Single-pole change-over contact as a quick-break contact. Permissible contact load: Category 5 3 (heating) AC 10 (4) A (inductive load at cos Ф = 0.6) / category 5 4 (cooling) AC 5 (4) A (inductive load at cos Ф = 0.6) / DC = max. 30 W Switching difference: approx. 1 K ± 0.8 K Color: RAL 7035 Width in (mm) 2.80 (71) Height in (mm) 2.80 (71) Depth in (mm) 0.14 (33.5) Rated operating voltage V, ~ Setting range 24 48-60 115, 1~ 230, 1~ 24 (DC) 48-60 (DC) 41 F...+140 F (+5 C...+60 C) Model No. 3110.000 Permissible contact load: AC ~ 5 (0.2) A (inductive load at cos Ф = 0.6) / DC = max. 20 W Setting range: 50 100% relative humidity Switching difference: approx. 4% Color: RAL 7035 Width in (mm) 2.80 (71) Height in (mm) 2.80 (71) Depth in (mm) 0.14 (33.5) Rated operating voltage V, ~ Setting range 24-230, 1~ 12-75 (DC) 41 F...+140 F (+5 C...+60 C) Model No. 3118.000 Conversion table for roof-mounted fans Air throughput, unimpeded air flow without fan 323 cfm (500 m³/h) 530 cfm (800 m³/h) 589 cfm (1000 m³/h) new 3138.000 old 8801.380 3148.007 230 V new 3139.100 3140.100 3140.500 old 3149.007 3149.420 3149.820 115 V new 3139.110 3140.110 3140.510 old 3169.007 3149.410 3149.810 400 V new 3140.140 old 3149.440 3149.840 Spare filter mats new 3174.100 old 3174.000 3174.000 3174.000 3174.000 133 400 258 400 258 Climate control/roof-mounted fans 11

Enclosures Power Distribution Climate Control IT Infrastructure Software & Services For more information scan the code at the left or visit www.rittalenclosures.com/fans-filters Rittal Corporation Woodfield Corporate Center 425 North Martingale Road, Suite 400 Schaumburg, Illinois 60173 USA Phone: 937-399-0500 Toll-free: 800-477-4000 Email: rittal@rittal.us Online: www.rittal.us Rittal Systems Ltd. 6485 Ordan Drive Mississauga, Ontario L5T 1X2 Canada Phone: 905-795-0777 Toll-free: 800-399-0748 E-Mail: marketing@rittal.ca Online: www.rittal.ca US330 4/17 Rittal Mexico Dr. Roberto Gayol 1219 1B Col. Del Valle Sur, 03100 Mexico, D.F. Phone: (+52) (55) 5559-5369 Toll-free: 01 800 8 Rittal (748.825) E-Mail: info@rittal.com.mx Website: www.rittal.com.mx