Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Similar documents
COMMERCIAL VENTILATION

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

SINGLE-ROOM ENERGY RECOVERY VENTILATORS

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

KOMFORT EC DB Suspended heat recovery air handling units

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

Residential Heat & Energy Recovery

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Caution: The fans must not be used in bath or shower enclosures.

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Destratification Fan Units DRF-VK & DRF-VKM & DRF-OV

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

Limited Lifetime core warranty. 5-year warranty on balance of unit.

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

Description of components and operating logic of the unit MICRA Ventilation system arrangement example based on the unit MICRA 60...

TECHNICAL SPECIFICATIONS

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

5 year fan housing and motor warranty

Series VENTS VUT R WH ЕС

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Put the V back in HVAC

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Outside Air Requirements... SOLVED!

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

HEAT RECOVERY VENTILATOR

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

Ventilation Solutions IAQ Canada

ENERGY SAVING VENTILATION GEO VENTS GEOTHERMAL SYSTEMS

DES CHAMPS PRODUCTS 85% 4,400 CFM

Tuning up ventilation systems

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

VERTICAL FAN COIL UNITS

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Light commercial models

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS

Product Catalog Commercial Solutions US Edition

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products

SINGLE-ROOM VENTILATION. for schools and public spaces

Product Catalog Commercial Solutions US Edition

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

HEAT RECOVERY VENTILATOR

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.)

Domestic & Commercial Fans

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

IAQ VENTILATION SOLUTIONS

Heat Recovery Ventilators models:

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

SER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

TR Series - The Ultimate ERV

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

SAFETY AND INSTALLATION MANUAL MODEL 8100

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

IAQ VENTILATION SOLUTIONS

USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.

50% 80% 7 Years. Filter. Ventilation Solutions IAQ Canada. Ventilate. of our time is spend indoors. Limited warranty on motors

Energy Recovery Ventilators

Heat or Energy Recovery Ventilation System

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

ENERGY RECOVERY VENTILATOR

Address of your installer

Tech to Tech May 07 HRV s & ERV s

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

10-year industry best core warranty. 5-year warranty on balance of unit.

Indoor Air Quality Product Brochure.

TEVHR. Heat Recovery Ventilator

INDOOR AIR QUALITY KITS AND ACCESSORIES /2014. Supersedes 06/2014

PHRV(R) Series. Heat Recovery Ventilator PHRV 140 PHRV 150 PHRV 200 PHRVR 155 PHRVR 160 PHRVR 205 PHRVR 210 PHRVR 305

SHR & VHR Models. SHR & VHR Series. Installation Manual. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST

FOR MODELS: VENMAR 1.3, 1.8 & 2.6 HE VENMAR 3055 & 5585 COMPACT vänee 1000, 2000 & 3000 HE

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Offices. Conference halls. Kindergartens Libraries. Restaurants. Schools. Sport halls. Shops

Ventilation Solutions IAQ Canada

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

INDOOR AIR QUALITY KITS AND ACCESSORIES /12 Supersedes 05/12

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704

READ AND SAVE THESE INSTRUCTIONS

Heat Recovery Energy Recovery Total Recovery Ventilators. Balanced Ventilation for Residential and Commercial Buildings. Advancing Ventilation

WHHR Midi & Midi Lite

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

Transcription:

Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5 Centralized Recovery Ventilators VUT 200 H mini...............................................................6 Brig HRV 120, 170............................................................8 Brig HRV 200, 300...........................................................10 Frigate HRV 60S, ERV 60S.....................................................12 Frigate HRV 120S, ERV 120S...................................................14 Frigate HRV 100DS, ERV 100DS, TRV 100DS, HRV 1DS, ERV 1DS, TRV 1DS.....16 Decentralised Recovery Ventilators TwinFresh S-60, S-60-2.......................................................18 TwinFresh R-, R--2.......................................................20 MICRA 60...................................................................22 Optional remote controls........................................................24 Quick Selection Table...........................................................26 2 VENTS. Air handling units 04-2014

VentsUS.com Select the correct Recovery Ventilation type (Heat Recovery Ventilation) HRV IIf you use a heating system more often than air conditioning, you need an HRV. Heat recovery systems have been designed to recover the heat contained in the extract air. Heat energy Latent energy (humidity) ERV (Energy Recovery Ventilation) If you use air conditioning more often than heating, an ERV is recommended. The enthalpic core of the ERV transfers heat and moisture from the intake air to the extract air. The air brought into the living area is cooled and the humidity is reduced for maximum comfort. The load on your air conditioner drops and you save on cooling costs. TRV (Twin Recovery Ventilation) TRV has the benefits of both HRV and ERV. You save heating in winter and air conditioning costs in summer. Moreover, you enjoy air with balanced humidity for maximum comfort. Select the ventilator model If your home is up to: Area of house Sq. Ft. HRV ERV TRV 1200 60S 60S 2000 100DS 100DS 100DS VUT 200 mini, 2400 120, 120S 120S 3000 1S 1S 1DS 3400 170 4000 200 6000 300 What is the difference? HRV Heat transfer Frostproof core Energy efficient rate ERV Heat transfer Humidity transfer Over dry and moisture damage prevention More energy efficient rate vs. HRV TRV Heat transfer Humidity transfer Over dry and moisture damage prevention Frostproof core Most energy efficient rate vs. HRV&ERV Aluminum or plastic core Enthalpic core Aluminum & Enthalpic core Fits to cold climate area Fits to hot and humid climate areas Fits to all climate areas Improve indoor air quality Provide fresh air Pre-heat intake air in winter time Pre-cool intake air in summer time Save on heating & air conditioning costs Washable filters Deliver fresh outdoor air Drives out harmful indoor pollutants VENTS. Air handling units 04-2014 3

How do HRV, ERV and TRV Systems work? HRV (Heat Recovery Ventilation) The fresh incoming air absorbs the heat from the air being extracted. This fresh warm air is then circulated back into the home or building. Intake air Extract air Dust, CO 2 and other pollutants Humidity Heat Energy Exhaust Air Static Plate (Plastic or metal) Recovery Heat Energy Outside Air Supply air Exhaust air Condensed Moisture Drain Pan ERV (Energy Recovery Ventilation) In the winter months the core captures the humidity of the extract air and circulates it back into the home or building. In summer the humidity is captured and exhausted outside. No drain pan is required. Intake air Extract air Supply air Dust, CO 2 and other pollutants Humidity Heat Energy Exhaust Air Static Plate (Paper) Recovery Heat Energy Return Humidity Outside Air Exhaust air TRV (Twin Recovery Ventilation) Drain Pan is not needed! Contains both HRV and ERV recovery cores inside. Both HRV and ERV cores of the Twin Recovery Ventilators provide "sensible" heat transfer. The HRV core makes Twin Recovery Ventilators suitable for cold climate zones and the ERV core increases the unit s efficiency by extra moisture transfer. Intake air Exhaust air Supply air Extract air 4 VENTS. Air handling units 04-2014

VentsUS.com Types of installation Independent System installation In this application the ductworks are used to supply fresh air to bedrooms and living areas and extract stale air from the bathroom, kitchen and laundry room. Exhaust at the source and supply in the return This application uses a separate duct system to extract air from the bathroom, kitchen and laundry room. The fresh air is dumped into the return air duct of the forced air system and is distributed in the house together with supply air. Exhaust and supply combined VENTS. Air handling units 04-2014 5

Centralized Recovery Ventilators VUT 200 H mini A Heat Recovery Ventilator is a complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of contaminated air. The HRV ventilators utilize the sensible energy in the heat recovery core. The special polymer core transfers heat from the extract air stream to the intake air stream so you save on energy costs. Features Efficient recovery ventilation Cross flow core with recuperation efficiency up to 80% Silent operation Replaceable filters Simple installation and maintenance Compact size Defrost system Casing Steel casing is covered with high-quality multilayer aluminium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened. Filter Washable G4 air filters in exhaust and supply air streams. Heat recovery core Specially designed aluminum plate core ensures excellent heat recovery efficiency. Whenever heat recovery is not required, the heat recovery block can be easily replaced by a "summer" block. The ventilator is also equipped with a drain pan for condensate drainage. Defrost system To protect the heat recovery core, the freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat recovery core, then the supply fan switches on and the ventilator continues operating under rated conditions. Motors German made high-efficient motor combined with backward inclined impeller delivers exceptionally powerful airflow and high static pressure. Built-in Thermal Overheating Protection with Automatic Restart makes the motor operation secure and reliable. Permanently lubricated ball bearings inside the motor provide long (40000 hours) trouble- and maintenance-free operation. Fans The ventilator is equipped with supply and exhaust centrifugal fans with backward inclined blades and built-in thermal overheating protection with automatic restart. The electric motors and the impellers are dynamically balanced in two planes. Control The ventilator comes with a thyristor speed control. Mounting The unit can be mounted in most positions and in most spaces. Please refer to installation manual for instructions and details. Warranty 5 year warranty Extract air Intake air Supply air Exhaust air 6 VENTS. Air handling units 04-2014

VentsUS.com Performance VUT 200 H mini Volts 120V, 60Hz Max. Max. Amps RPM Airflow CFM 0" 0,125" 0,25" 0,5" 0,75" 1.0" 1.25" 1.5" Heat recovery core efficiency, % 207 1.8 3040 125 123 119 106 89 69 44 14 < 80% 4'' Duct Dia. Flow Rate, [L/s] 0 10 20 30 40 60 70 Static Pressure [in. WG] 1.2 1.0 0.8 0.6 0.4 VUT 200 mini 300 2 200 1 100 Static Pressure [Pa] 0.2 0.0 0 0 20 40 60 80 100 120 140 160 Flow Rate, [CFM] Dimensions Accessories 10 15/16 15 13/16 Ø 4" Air disk valve 23 5/8 Backdraft Dampers Clamps VENTS. Air handling units 04-2014 4 7

Brig HRV 120, 170 A Heat Recovery Ventilator is a complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air. Features Efficient recovery ventilation Cross flow core with recuperation efficiency up to 80% Silent operation Replaceable filters Simple installation and maintenance Compact size Defrost system Casing Steel casing is covered with high-quality multilayer aluminium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened. Filter Washable G4 air filters in exhaust and supply air streams. Optional supply: anti grease filter. Heat recovery core Specially designed polymer plate core ensures excellent heat recovery efficiency. Whenever heat recovery is not required, the heat recovery block can be easily replaced by a "summer" block. The ventilator is also equipped with a drain pan for condensate drainage. Defrost system To protect the heat recovery core, the freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat recovery core, then the supply fan switches on and the ventilator continues operating under rated conditions. Motors German made high-efficient motor combined with backward inclined impeller delivers exceptionally powerful airflow and high static pressure. Built-in thermal overheating protection with automatic restart makes the motor operation secure and reliable. Permanently lubricated ball bearings inside the motor provide long (40000 hours) trouble- and maintenance-free operation. Fans The ventilator is equipped with supply and exhaust centrifugal fans with backward inclined blades and built-in thermal overheating protection with automatic restart. The electric motors and the impellers are dynamically balanced in two planes. Control The ventilator is equipped with 3-step switch on it's side panel to choose STANDBY, LOW or MEDIUM mode for continuous operation. The unit can be equipped with wide range of additional controls (page 24) to switch boost on demand. Mounting The unit can be mounted in most positions and in most spaces. Please refer to installation manual for instructions and details. Warranty 5 year warranty Extract air Intake air Supply air Exhaust air 8 VENTS. Air handling units 04-2014

VentsUS.com Performance HRV 120 HRV 170 Volts 120V, 60Hz 120V, 60Hz Max. Max. Amps RPM 0,1" (25Pa) 135 1.1 2590 177 (84) 207 1.83 3040 193 (91) 0,2" (Pa) 160 (76) 178 (84) 0,3" (75Pa) 147 (69) 167 (79) 0,4" (100Pa) 131 (62) 153 (72) 0,5" (125Pa) 118 (56) 143 (67) Airflow CFM (L/s) 0,6" (1Pa) 105 () 133 (63) 0,7" (175Pa) 92 (43) 123 (58) 0,8" (200Pa) 77 (36) 113 (53) 0,9" (225Pa) 62 (29) 103 (49) 1,0" (2Pa) 45 (21) 91 (43) 1,2" (300Pa) - - 69 (33) 1,4" (3Pa) - - 40 (19) Heat recovery core efficiency, % Duct Dia. < 80% 6'' < 80% 6'' Sensible efficiency(%) at 56 cfm 80 cfm 160 cfm 120 cfm HRV 120 74 69 59 63 Sensible efficiency(%) at 62 cfm 89 cfm 178 cfm 133 cfm HRV 170 74 68 58 62 Flow Rate, [L/s] 0 10 20 30 40 60 70 80 90 Flow Rate, [L/s] 0 10 20 30 40 60 70 80 90 Static Pressure [in. WG] 1.0 0.8 0.6 0.4 HRV 120 2 200 1 100 Static Pressure [Pa] Static Pressure [in. WG] 1.4 1.2 1.0 0.8 0.6 0.4 HRV 170 3 300 2 200 1 100 Static Pressure [Pa] 0.2 0.2 0.0 0 0 40 80 120 160 200 Flow Rate, [CFM] 0.0 0 0 40 80 120 160 200 Flow Rate, [CFM] 208 134 131 128 HRV 120 203 198 193 HRV 170 Dimensions Accessories Ø 6" 19 11/16 " 19 3/4 " Air disk valve 9 3/4 " 25 9/16 " Backdraft Dampers Clamps VENTS. Air handling units 04-2014 4 9

Brig HRV 200, 300 A Heat Recovery Ventilator is a complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air. Features Multizonal efficient recovery ventilation Cross flow core with recuperation efficiency up to 80% Silent operation Replaceable filters Simple installation and maintenance Compatible with 6 and 8 air ducts Electronic defrost protection Casing Steel casing is covered with high-quality multilayer aluminium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened. Filter Washable G4 air filters in exhaust and supply air streams. Optional supply: anti grease aluminum filter. Heat recovery core Specially designed polymer plate core ensure the top heat recovery efficiency. Whenever heat recovery is not required for unit operation the heat exchanger block can be easily replaced by a summer block. The unit is also equipped with the drain pan for condensate. Defrost system To protect the heat recovery core, the freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat recovery core, then the supply fan switches on and the ventilator continues operating under rated conditions. Motors German made high-efficient motor combined with backward inclined impeller delivers exceptionally powerful airflow and high static pressure. Built-in thermal overheating protection with automatic restart makes the motor operation secure and reliable. Permanently lubricated ball bearings inside the motor provide long (40000 hours) trouble- and maintenance-free operation. Fans The ventilator is equipped with supply and exhaust centrifugal fans with backward inclined blades and built-in thermal overheating protection with automatic restart. The electric motors and the impellers are dynamically balanced in two planes. Control The ventilator is equipped with 3-step switch on it's side panel to choose STANDBY, LOW or MEDIUM mode for continuous operation. The unit can be equipped with wide range of additional controls (page 24) to switch boost on demand. Mounting The unit can be mounted in most positions and in most spaces. Please refer to installation manual for instructions and details. Warranty 5 year warranty Extract air Intake air Intake air Extract air Supply air Exhaust air Exhaust air Supply air HRV 200 HRV 300 10 VENTS. Air handling units 04-2014

VentsUS.com Performance HRV 200 HRV 300 Volts 120V, 60Hz 120V, 60Hz Max. Max. Amps RPM 0,1" (25Pa) 224 1.9 3040 234 (110) 465 3.9 20 390 (184) 0,2" (Pa) 226 (107) 380 (179) 0,3" (75Pa) 218 (103) 365 (172) 0,4" (100Pa) 203 (96) 340 (160) 0,5" (125Pa) 191 (90) 315 (149) 0,6" (1Pa) 178 (84) 287 (135) Airflow CFM (L/s) 0,7" (175Pa) 164 (77) 258 (122) 0,8" (200Pa) 152 (72) 233 (110) 0,9" (225Pa) 138 (65) 208 (98) 1,0" (2Pa) 123 (58) 184 (87) 1,2" (300Pa) 86 (41) 137 (65) 1,4" (3Pa) 42 (20) 97 (46) 1,6" (400Pa) 1,8" (4Pa) Heat recovery core efficiency, % Duct Dia. - - < 80% 6'' 55 (26) 22 (10) < 80% 8'' Sensible efficiency(%) at 79 cfm 113 cfm 226 cfm 169 cfm HRV 200 77 71 57 67 Sensible efficiency(%) at 133 cfm 190 cfm 380 cfm 285 cfm HRV 300 70 65 52 59 1.6 Flow Rate, [L/s] 0 20 40 60 80 100 2.0 Flow Rate, [L/s] 0 20 40 60 80 100 120 140 160 180 Static Pressure [in. WG] 1.4 1.2 1.0 0.8 0.6 0.4 HRV 200 3 300 2 200 1 100 Static Pressure [Pa] Static Pressure [in. WG] 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 HRV 300 4 400 3 300 2 200 1 100 Static Pressure [Pa] 0.2 0.2 0.0 0 0 100 1 200 2 Flow Rate, [CFM] 0.0 0 0 100 1 200 2 300 3 400 Flow Rate, [CFM] 467 223 220 217 HRV 200 463 459 455 HRV 300 Dimensions Accessories Ø 6" 177 3/16 15/16 " Ø 8" 17 5/16 " 23 11/16 5/8 " 25 11/16 " 11 3/4 " 12 3/4 " Air disk valve 28 7/16 3/8 " 36 3/4 " HRV 200 HRV 300 Backdraft Dampers Clamps VENTS. Air handling units 04-2014 4 11

Frigate HRV 60S, ERV 60S Both Heat and Energy Recovery Ventilators are the complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air. Features Effective energy-saving solution Efficient recovery ventilation Cross flow core with recuperation efficiency up to 80% Heat recovery (HRV) or Energy Recovery (ERV) Silent operation Replaceable filters Ceiling installation Simple installation and maintenance Compact size Casing Steel casing is covered with high-quality multilayer aluminium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened. Filter Washable G4 air filters in exhaust and supply air streams. Optional supply: anti grease aluminum filter. Heat recovery core The aluminum cross-flow core (HRV 60s) ensures efficient heat recovery and the enthalpic core (ERV 60s) provides both heat&energy recovery. Defrost system To protect the heat recovery core, the freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat recovery core, then the supply fan switches on and the ventilator continues operating under rated conditions. Motor German made high-efficient motor combined with backward inclined impeller delivers exceptionally powerful airflow and high static pressure. Built-in thermal overheating protection with automatic restart makes the motor operation secure and reliable. Permanently lubricated ball bearings inside the motor provide long (40000 hours) trouble- and maintenance-free operation. Fans The ventilator is equipped with supply and exhaust centrifugal fans with forward inclined blades and built-in thermal overheating protection with automatic restart. The electric motors and the impellers are dynamically balanced in two planes. Control The ventilator is supplied with a thyristor speed control. The unit can be equipped with wide range of additional controls (page 24) to switch boost on demand. Mounting The unit is mounted suspended to the ceiling with special belts. Please refer to installation manual for instructions and details. Warranty 5 year warranty Intake air Exhaust air Extract air Supply air 12 VENTS. Air handling units 04-2014

VentsUS.com Performance HRV 60S ERV 60S Volts Max. Max. Amps 120V, 60Hz 44 0.64 RPM 0,1" (25Pa) 63 (30) 0,2" (Pa) 56 (26) Airflow CFM (L/s) 0,3" (75Pa) (24) 0,4" (100Pa) 38 (18) 0,5" (125Pa) 24 (11) 0,6" (1Pa) 9 (4) Heat recovery core efficiency, % Duct Dia. < 80% 5 Sensible efficiency(%) at 28 cfm 39 cfm 56 cfm 47 cfm HRV 60S 67 62 57 60 Sensible efficiency(%) at 28 cfm 39 cfm 56 cfm 47 cfm ERV 60S 69 64 59 62 Flow Rate, [L/s] 0 5 10 15 20 25 30 0.7 Static Pressure [in. WG] 0.6 0.5 0.4 0.3 0.2 HRV 60S ERV 60S 1 125 100 75 Static Pressure [Pa] 0.1 25 0.0 0 10 20 30 40 60 70 Flow Rate, [CFM] 0 45 43 41 39 HRV 60S ERV 60S Dimensions Accessories Ø 5" 14 3/4 " 8 7/16 " Air disk valve 6 7/16 " 19 1/2 " Backdraft Dampers Clamps VENTS. Air handling units 04-2014 4 13

Frigate HRV 120S, ERV 120S Heat and Energy Recovery Ventilators are the complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air. Features Effective energy-saving solution Multizonal efficient recovery ventilation Cross flow core with recuperation efficiency up to 80% Heat recovery (HRV) or Energy Recovery (ERV) Silent operation Replaceable filters Ceiling installation Simple installation and maintenance Casing Steel casing is covered with high-quality multilayer aluminium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened. Filter Washable G4 air filters in exhaust and supply air streams. Optional supply: anti grease aluminum filter. Heat recovery core Aluminum cross-flow core (HRV 120s) ensures efficient heat recovery and enthalpic core (ERV 120s) provides both heat&energy recovery. Defrost system To protect the heat recovery core, the freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat recovery core, then the supply fan switches on and the ventilator continues operating under rated conditions. Motors German made high-efficient motor combined with backward inclined impeller delivers exceptionally powerful airflow and high static pressure. Built-in thermal overheating protection with automatic restart makes the motor operation secure and reliable. Permanently lubricated ball bearings inside the motor provide long (40000 hours) trouble- and maintenance-free operation. Fans The unit is equipped with supply and exhaust centrifugal fans with backward curved blades and build-in thermal overheating protection with automatic restart. The electric motors and the impellers are dynamically balanced in two planes. Control The ventilator is designed for permanent low speed operation. High speed can be turned on and off with the external switch. Both low and high speed are adjustable. The ventilator's speed is controlled with a 3-step speed switch located on the ventilator's side panel: LOW mode - minimum speed, MED mode - medium speed. In STANDBY mode the ventilator is controlled from the remote controller SAS 908 (optional supply). Mounting The unit is mounted suspended to the ceiling with special belts. Please refer to installation manual for instructions and details. Warranty 5 year warranty Intake air Exhaust air Extract air Supply air 14 VENTS. Air handling units 04-2014

VentsUS.com Performance HRV 120S ERV 120S Volts 120V, 60Hz Max. Max. Amps RPM 142 1.23 2460 0,1" (25Pa) 1 (71) 0,2" (Pa) 143 (67) 0,3" (75Pa) 137 (65) 0,4" (100Pa) 127 (60) Airflow CFM (L/s) 0,5" (125Pa) 116 (55) 0,6" (1Pa) 104 (49) 0,7" (175Pa) 91 (43) 0,8" (200Pa) 78 (37) 0,9" (225Pa) 64 (30) 1,0" (2Pa) 49 (23) 1,2" (300Pa) 18 (8) Heat recovery core efficiency, % Duct Dia. < 80% 5'' Sensible efficiency(%) at cfm 71 cfm 143 cfm 107 cfm HRV 120S 57 53 40 46 Sensible efficiency(%) at cfm 71 cfm 143 cfm 107 cfm ERV 120S 61 57 44 Flow Rate, [L/s] 0 10 20 30 40 60 70 Static Pressure [in. WG] 1.2 1.0 0.8 0.6 0.4 HRV 120S ERV 120S high 300 2 200 1 100 Static Pressure [Pa] 0.2 low 0.0 0 0 20 40 60 80 100 120 140 160 Flow Rate, [CFM] 1 125 100 75 low high HRV 120S ERV 120S Dimensions Accessories Ø 5" 20" 8 1/4 Air disk valve 9 15/16 " 21" Backdraft Dampers Clamps VENTS. Air handling units 04-2014 4 15

Frigate HRV 100DS, ERV 100DS, TRV 100DS, HRV 1DS, ERV 1DS, TRV 1DS All Heat, Energy and Total Recovery Ventilators are the complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air. Features Effective energy-saving solution Multizonal efficient recovery ventilation Enhanced output capacity Double cross flow cores with recuperation efficiency up to 90% Increased Heat (HRV) and (ERV) Energy Recovery Advantages of HRV and ERV in one unit Silent operation Replaceable filters Ceiling installation Casing Steel casing is covered with high-quality multilayer aluminium and zinc alloy to prevent corrosion. The casing is equipped with switch to turn the ventilator off when the service panel is opened. Filter Washable G4 air filters in exhaust and supply air streams. Optional supply: anti grease aluminum filter. Heat recovery core Two aluminum cross-flow cores (HRV 100Ds and HRV 1Ds) ensure the most efficient heat recovery. Two enthalpic cores (ERV 100Ds and ERV 1Ds) provide both heat&energy recovery. Unique combination of aluminum and enthalpic cores attains the best heat&energy recovery efficiency. Defrost system To protect the heat recovery core, the freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat recovery core, then the supply fan switches on and the ventilator continues operating under rated conditions. Motor German made high-efficient motor combined with backward inclined impeller delivers exceptionally powerful airflow and high static pressure. Built-in Thermal Overheating Protection with Automatic Restart makes the motor operation secure and reliable. Permanently lubricated ball bearings inside the motor provide long (40000 hours) trouble- and maintenance-free operation. Fans The ventilator is equipped with supply and exhaust centrifugal fans with backward inclined blades and built-in thermal overheating protection with automatic restart. The electric motors and the impellers are dynamically balanced in two planes. Control The ventilator is designed for permanent low speed operation. High speed can be turned on and off with the external switch. Both low and high speed are adjustable. The ventilator's speed is controlled with a 3-step speed switch located on the ventilator's side panel: LOW mode - minimum speed, MED mode - medium speed. In STANDBY mode the ventilator is controlled from the remote controller SAS 908 (optional supply). Mounting The unit is mounted suspended to the ceiling with special belts. Please refer to installation manual for instructions and details. Warranty 5-year warranty Intake air Sensible efficiency(%) at 40 cfm 57 cfm 115 cfm 86 cfm Exhaust air HRV 100DS 75 73 61 65 ERV 100DS 78 76 64 69 TRV 100DS 77 75 63 67 Sensible efficiency(%) at 52 cfm 74 cfm 148 cfm 111 cfm HRV 1DS 71 68 58 62 ERV 1DS 75 72 62 66 Supply air TRV 1DS 74 71 61 65 Extract air 16 VENTS. Air handling units 04-2014

VentsUS.com Performance HRV 100DS ERV 100DS TRV 100DS HRV 1DS ERV 1DS TRV 1DS Volts 120V, 60Hz 120V, 60Hz Max. Max. Amps RPM 139 1.2 3040 215 1.83 3040 0,1" (25Pa) 120 (57) 1 (71) 0,2" (Pa) 115 (54) 148 (70) 0,3" (75Pa) 109 (51) 144 (68) 0,4" (100Pa) 98 (46) 136 (64) 0,5" (125Pa) 88 (42) 128 (60) Airflow CFM (L/s) 0,6" (1Pa) 77 (36) 120 (57) 0,7" (175Pa) 65 (31) 111 (52) 0,8" (200Pa) 52 (25) 101 (48) 0,9" (225Pa) 38 (18) 91 (43) 1,0" (2Pa) 24 (11) 79 (37) 1,2" (300Pa) 1,4" (3Pa) Heat recovery core efficiency, % Duct Dia. - - < 90% 5 53 (25) 23 (11) < 90% 5 Flow Rate, [L/s] 0 10 20 30 40 60 Flow Rate, [L/s] 0 10 20 30 40 60 70 Static Pressure [in. WG] 1.0 0.8 0.6 0.4 HRV 100DS ERV 100DS TRV 100DS high 2 225 200 175 1 125 100 75 Static Pressure [Pa] Static Pressure [in. WG] 1.4 1.2 1.0 0.8 0.6 0.4 HRV 1DS ERV 1DS TRV 1DS high 3 300 2 200 1 100 Static Pressure [Pa] 0.2 low 25 0.2 low 0.0 0 20 40 60 80 100 120 Flow Rate, [CFM] 0 0.0 0 20 40 60 80 100 120 140 160 Flow Rate, [CFM] 0 1 230 125 100 75 low high HRV 100DS ERV 100DS TRV 100DS 190 1 110 70 low high HRV 1DS ERV 1DS TRV 1 DS Dimensions Accessories Ø 5" 20 3/8 " 8 1/4 " Air disk valve 12 11/16 " 30 3/16 " Backdraft Dampers Clamps VENTS. Air handling units 04-2014 4 17

Single Room TOTAL Recovery Ventilators TwinFresh S-60, S-60-2 Benefits No need to pay for air ducts No need to pay for grilles No need to pay for installation of complicated ventilation duct system Extremely high ERV core efficiency up to 91% Features: The ventilator with a square air duct is specially designed for easy mounting in new construction. Efficient supply and exhaust single room ventilation High-tech polymer ceramic energy accumulator with regenerating efficiency up to 91% EC-motor Integrated automation with four operating patterns Silent operation (0.5 0.81 Sones) Easy installation Air purification with two built-in G3 filters Rated for continuous operation The Single Room Total Recovery ventilator TwinFresh S is an easy and effective solution for rooms and smaller areas. Front grille (1) Modern design of the front grille makes it look great in any interior. Easy access for filter cleaning or replacement. The front grille is made of high quality snow-white ABS plastic. Air filtration (2) Two G3 built-in filters provide fresh air free of dust, pollen, insects. Motor (3) 1 2 The latest EC-motor technology ensures low energy costs.the motor has integrated overheating protection and ball bearings for longer service life. Polymer ceramic energy accumulator (regenerator) (4) The ventilator includes a high-tech polymer ceramic energy accumulator with regenerating efficiency up to 91%. 3 4 5 Control and operating modes The automation system has four operating patterns: 1. Ventilation mode (extract or supply mode) at low speed with air capacity 20.6 CFM; 2. Ventilation mode (extract or supply mode) at high speed with air capacity 34.1 CFM; 3. Reverse mode (regeneration) at low speed with air capacity 20.6 CFM; 4. Reverse mode (regeneration) at high speed with air capacity 34.1 CFM The required operation mode is selected using the control panel supplied with the model TwinFresh SA. The control panel for the model TwinFresh S is available upon separate order. Exterior Protection (5) The exterior is constructed of aluminum covered with a special polymer coating to ensure long-lasting protection from the elements. A grill protects water and foreign objects from entering the unit. Supply/ extract mode Reverse mode On High speed Low speed Off Supplied with TwinFresh SA only 18 VENTS. Air handling units 04-2014

VentsUS.com How the TwinFresh S Works CYCLE I. Warm stale air is extracted from the room passing through the ceramic accumulator, which captures up to 91% of the thermal energy of the air being extracted. As the accumulator gets heated, the ventilator switches to air supply mode. CYCLE II. As the fresh outside air passes the opposite way through the accumula- 14 o F 68 o F 68 o F 70 sec. AIR EXTRACT CYCLE I 68 o F tor, it absorbs the heat and moisture which was extracted from the room air that was exhausted. As the temperature of the accumulator decreases, the fan switches back to extraction mode and the cycle starts all over again. The ventilator changes its operation mode for supply or extract ventilation every 70 seconds. This time 14 o F interval can be adjusted during installation from 30 to 120 seconds. 14 o F AIR SUPPLY 70 sec. 68 o F CYCLE II Technical data 14 o F TwinFresh S Speed Voltage [V] Power [W] Air capacity [CFM] Rotation speed [min -1 ] Sones 1 2,4 20.6 11 0.5 120/60 Hz 2 3,0 34.1 2100 0.81 Ingress protection rating IP 45 *In reverse mode the stated air capacity is shared for both directions Overall dimensions [inch] Accessories TwinFresh S-60 10" 6 7/16" Replaceable front grilles 10 1/16" 18 11/16" 11 5/8" RV TwinFresh S alumat Grey metallic RV TwinFresh S alu Natural brushed aluminium 2 13/16" RV TwinFresh S gold Natural gold painted aluminium RV TwinFresh S chrome Natural mirror aluminium 10 13/16" TwinFresh S-60-2 12 3/8" 6 7/16" 4 3/4" - 13" 12 3/8" 8 11/16" 10 13/16" Control panel KVS Power transformer TRF 110/12-6 (6 W) TRF 110/12-12 (12 W) VENTS. Air handling units 04-2014 19

TwinFresh R-, R--2 Benefits No need to pay for air ducts No need to pay for grilles No need to pay for installation of complicated ventilation duct system Extremely high ERV core efficiency up to 91% Features: The ventilator with a round duct is specially designed for easy mounting in refurbished and reconstructed ready-built buildings. Efficient supply and exhaust single room ventilation High-tech ceramic energy accumulator with regenerating efficiency up to 91% EC-motor Integrated automation with four operating patterns Silent operation (0.5 0.81 Sones) Easy installation Air purification with two built-in G3 filters Rated for continuous operation 1 2 The Single Room Total Recovery ventilator TwinFresh R is an easy and effective solution for rooms and smaller areas. Front grille (1) Modern design of the front grille makes it look great in any interior. The grille is fitted with a thermal actuator and automatic louvre shutters that are opened during operation of the ventilator and are closed during standby. The front grille is made of high quality snow-white ABS plastic. Air filtration (2) Two G3 built-in filters provide fresh air free of dust, pollen, insects. Motor (3) 4 The latest EC-motor technology ensures low energy costs. The motor has integrated overheating protection and ball bearings for longer service life. Polymer ceramic energy accumulator (regenerator) (4) 3 5 The ventilator includes a high-tech polymer ceramic energy accumulator with regenerating efficiency up to 91%. Control and operating modes The automation system has four operating patterns: 1. Ventilation mode (extract or supply mode) at low speed with air capacity 14.7 CFM; 2. Ventilation mode (extract or supply mode) at high speed with air capacity 29.4 CFM; 3. Reverse mode (regeneration) at low speed with air capacity 14.7 CFM; 4. Reverse mode (regeneration) at high speed with air capacity 29.4 CFM The required operation mode is selected using the control panel supplied with the model TwinFresh RA. The control panel for the model TwinFresh R is available upon separate order. Exterior Protection (5) Supply/ extract mode Reverse mode High speed Low speed The exterior is constructed of aluminum covered with a special polymer coating to ensure long-lasting protection from the elements. A grill protects water and foreign objects from entering the unit. Supplied with TwinFresh RA only On Off 20 VENTS. Air handling units 04-2014

VentsUS.com How the TwinFresh R Works 68 o F 70 AIR EXTRACT CYCLE I CYCLE I. Warm stale air is extracted from the room passing through the ceramic accumulator, which captures up to 91% of the thermal energy of the air being ex- 14 o F sec. tracted. As the accumulator gets heated, the ventilator switches to air supply mode. CYCLE II. As the fresh outside air passes the opposite way through the accumula- 68 o F 68 o F tor, it absorbs the heat and moisture which was extracted from the room air that was exhausted. As the temperature of the accumulator decreases, the fan switches back to extraction mode and the cycle starts all over again. The ventilator changes 14 o F its operation mode for supply or extract ventilation every 70 seconds. This time interval can be adjusted during installation from 30 to 120 seconds. 14 o F AIR SUPPLY 70 sec. 68 o F CYCLE II Technical data 14 o F TwinFresh R Speed Voltage [V] Power [W] Air capacity [CFM] Rotation speed [min -1 ] Sones 1 1,4 14.7 570 0.5 120/60 Hz 2 3,0 29.4 1100 0.81 Ingress protection rating IP 45 *In reverse mode the stated air capacity is shared for both directions Overall dimensions [inch] Accessories 10" 6 1/8" TwinFresh R- 9 13/16" - 18 1/2" 101 3/16" Rectangular plastic grille MV 125 VDs Angle mounting kit NP 60х204-0021 2 13/16" 8 3/8" TwinFresh R--2 6 1/8" 9 5/8" Round plastic grille MV 1 bvs Stainless steel outer hood MV 152 bvs N 4 3/4" - 13 3/8" 9 3/4" 8 7/16" 8 3/8" Control panel KVR Power transformer TRF 110/12-6 (6 W) TRF 110/12-12 (12 W) VENTS. Air handling units 04-2014 21

Single room HRV MICRA 60 Micra 60 is the single room heat recovery ventilator for larger rooms and areas, including apartments and small commercial spaces. No need to connect air ducts. A great solution for simple and efficient ventilation in retrofits. Features Efficient heat recovery ventilation for separate rooms Up to 90% energy recovery efficiency. EC-motor Three operating modes Silent operation (0.38 1.0 Sones) Air cleaning with two G4 built-in filters Easy mounting Suitable for continuous operation 2 1 Casing (1) Polymer coated metal casing decorated with mirror stainless steel and internally filled with 9/16" thermal and sound insulating layer. Modern unit design makes it match well with any interior. The removable front panel provides easy access for filter cleaning or replacement. Air is supplied to the room and exhausted outside through two 5" air ducts. Air filtration (2) Two G4 built-in filters provide cleaning of supply and extract air. The filters serve to ensure supply of fresh air free of dust, pollen and insects and protect the unit from soiling. 3 Motor (3) Axial fans are powered by energy-efficient EC-motors. The motors are equipped with built-in thermal overheating protection and ball bearings for longer service life. Heat recovery core (4) The ventilator is equipped with a high-tech plate counter-flow aluminium heat recovery core reaching up to a 78% recovery efficiency. Using the MICRA in both cooling and heating seasons results in considerable energy savings. 4 5 Freeze protection The MICRA includes special thermostats that prevent any condensate from freezing. Control unit (5) The unit is powered through an integrated pulser unit with a wide range of supply voltage from 100 V to 240 V and frequency from to 60 Hz. The power unit has integrated protection for various emergencies including short circuit, overload, voltage jumps, reverse polarity in output circuits. Control and operation modes Automatic system enables three operation modes: 1. Supply and exhaust ventilation at minimum air capacity 17.7 CFM and minimum noise level 0.38 Sones. 2. Supply and exhaust ventilation at medium air capacity 26.5 CFM and minimum noise level 0.42 Sones. 3. Supply and exhaust ventilation at medium air capacity 35.3 CFM and minimum noise level 1.0 Sones. 22 VENTS. Air handling units 04-2014

VentsUS.com How it Works Fresh air from outside moves through the filter and core. Warm stale air from the room moves through the filter and core and then is exhausted outside. The thermal energy of the extracted warm inside air is transferred to the fresh outside air that is being drawn in. The intake and extract air flows are fully separated. Supply filter Extract filter Supply air Heat recovery core Extract air Technical data Speed Voltage Micra 60 Power [W] Current [A] Air capacity [CFM] Rotation speed [min -1 ] Sones 1 4,2 0,02 17,7 1165 0.38 2 100-240 V -60 Hz 9,6 0,04 26,5 1720 0.42 3 15,4 0,07 35,3 2685 1.0 Ingress protection rating IP 22 Overall dimensions [inch] Accessories dimensions [inch] 7 3/8" 7 5/16" 14" 15 1/4" 4 3/4" 15 1/2" 2 5/16" О 4 7/8" Mounting set MK MICRA 60: two air ducts PVC19 11/16 long; one outer metal twin hood. 5 1/8" 20 3/8" 20 11/16" 5 1/8" Mounting metal master plate MP MICRA 60. Used to fix air ducts in required position and to align the unit branch pipes and air ducts precisely. The master plate is installed during general construction stage. VENTS. Air handling units 04-2014 23

Optional remote controls TRANSMITTER CO 2 Thermostat SAS908PIT The modulating digital thermostat is designed to select one of three fan speeds. As the thermostat is off the unit is switched to STANDBY mode. The product also provides proportional-integral temperature regulation of fancoil dampers, equipment for zonal heating in commercial applications and transfers air conditioning control signals. CO 2 transmitter For offices or other public places. Provides high speed ventilation when CO 2 level exceeds selected setting. Ventilator Important Base module Low Voltage is 24 Volt AC. Do not connect external power sources to the ventilator! 2 Wire conrtol Devices (Low Woltage) OFF 60 10 ON 20% 30% 40% 40 20 10 % 30 OFF OFF MAX CRANK TIMER TOGGLE SWITCH HUMIDITY CONTROL Crank Timer Location: bathroom or kitchen area to bring on high speed ventilation as required Crank Timer 60 min Toggle switch Important Base module Low Voltage is 24 Volt AC. Do not connect external power sources to the ventilator! Remote dehumidistat Location: kitchen and bathroom, SPA or swimming pool (anywhere humidity is a concern). Provides high speed ventilaion when humidity level selected setting. SPEED CONTROL Speed control LOW STANDBY MED Each unit is equipped with one three-key speed switch to select low speed or medium speed. In STANDBY mode the unit is waiting to response to external signal. All double-wire devices switch the units to maximum speed irrespective of the switch position. 24 VENTS. Air handling units 04-2014

20% 10 % OFF 30% MAX 40 60 OFF 30 CRANK TIMER 20 ON OFF VentsUS.com Electrical accessories compatibility Thermostat SAS908PIT Remote dehumidistat CO 2 transmitter Crank Timer Toggle switch Speed control RS 1-400 Four position switch Control unit 40% CO 2 TRANSMITTER 10 HUMIDITY CONTROL TOGGLE SWITCH Vents VUT 200 mini Vents Brig HRV 120 Vents Brig HRV 170 Vents Brig HRV 200 Vents Brig HRV 300 Vents Frigate HRV 60S Vents Frigate ERV 60S Vents Frigate HRV 120S Vents Frigate ERV 120S Vents Frigate HRV 100 DS Vents Frigate ERV 100 DS Vents Frigate TRV 100 DS Vents Frigate HRV 1 DS Vents Frigate ERV 1 DS Vents Frigate TRV 1 DS TwinFresh R TwinFresh S Micra 60 VENTS. Air handling units 04-2014 25

Quick Selection Table Heat Recovery Ventilators (HRV) Area of house Sq. Ft Up To 1200 Up To 2000 Up To 2400 Up To 3000 Up To 3400 Up To 4000 Up To 6000 HRV 60S HRV 100DS VUT 200 mini HRV 120S HRV 120 HRV 1DS HRV 170 HRV 200 HRV 300 (HRV) Duct Dia. 5'' 5'' 4'' 5'' 6'' 5'' 6'' 6'' 8'' Max. 44 139 207 142 135 215 207 465 224 Airflow CFM (L/s) 56 (26) 115 (54) 125 143 (67) 160 (76) 148 (70) 178 (84) 226 (107) 380 (179) Efficiency of heat exchanger, % < 80% < 90% < 80% < 80% < 80% < 90% < 80% < 80% < 80% Energy Recovery Ventilators (ERV)/Total Recovery Ventilators (TRV) Area of house Sq. Ft Up To 1200 Up To 2000 Up To 2400 Up To 3000 ERV 60S ERV 100DS HRV 120S ERV 1DS (ERV) TRV 100DS TRV 1DS (TRV) Duct Dia. 5'' 5'' 5'' 5'' Max. 44 139 142 215 Airflow CFM (L/s) 56 (26) 115 (54) 143 (67) 148 (70) Efficiency of heat exchanger, % < 80% < 90% < 80% < 90% Certification 26 VENTS. Air handling units 04-2014

Tel: 1-888-640-0925 Tel: 513-348-3853 Fax: 513-268-4597 sales@ventsus.com VentsUS.com 11013 Kenwood Road Cincinnati, Ohio 45242 04/2014