PACKAGED COMMERCIAL WATERTUBE BOILERS

Similar documents
PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Originators of the Flexible Water Tube design

Development of Boiler Design

When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units.

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design

Suggested Specifications Prestige Excellence 110

AIM OF THE EXPERIMENT:- Study of boilers (fire tube, water tube) APPARATUS REQUIRED: - SL.NO NAME OF THE APPARATUS SPECIFICATION QUANTITY 01 Fire tube

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

STR-Series Indirect-Fired Air Turnover Units

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

Boiler Basics: Design & Application Differences. Presented by Steve Connor July 30, 2014

FLX FLEXTUBE. The Widest Range of Hydronic and Steam Watertube Boiler Systems 1,500 to 25,000 MBTU/HR (35-600HP)

CONTENTS. B. System Design and Performance Requirements

Solution builder. in energy management.

Revitalize Building Mechanical Systems (4619)

Section B1. Flexible Watertube Boilers TABLE OF CONTENTS

DIVISION FINNED WATER-TUBE BOILERS

B duced by combustion) to a fluid. The definition has been

SECTION WATER-TUBE BOILERS

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Fuel-Fired Vertical Tubeless Boilers

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

FUEL-FIRED VERTICAL TUBELESS BOILERS

SECTION HEATING BOILERS

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

G315/6 Cast Iron Boiler

mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

.2 Section Waste Management and Disposal..4 Section Vibration Isolation and Seismic Control Measures.

DIVISION FINNED WATER-TUBE WATER HEATERS

Installation and Operating Instructions. Precision Flextube Boilers. FTS Series STEAM BOILERS

G315/5 Cast Iron Boiler

SAMPLE SPECIFICATIONS

G515/7 Cast Iron Boiler

DIVISION FINNED WATER-TUBE WATER HEATERS

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

G615/11 Cast Iron Boiler

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Boiler. Fire tube Boiler:

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

DIVISION FINNED WATER-TUBE BOILERS

Boiler Basics. Design and operation

WATER-TUBE POOL HEATERS

FINNED WATER-TUBE POOL HEATERS

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity

Automatic Circulating Water Heaters

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION FIRE TUBE BOILERS (STEAM)

SECTION PLUMBING EQUIPMENT

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

WATER-TUBE POOL HEATERS

CHAPTER 10 STEAM AND HOT WATER BOILERS

INDUSTRIAL WATERTUBE BOILERS

MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel.

FXLF-9. High Efficiency Water Heaters and Boilers

ALDRICH COMPANY THREE PASS FIRETUBE BOILER CLASSIC SERIES OPERATING & MAINTENANCE MANUAL

Attachment A District 1000 Boiler Replacement District 10 Project # Building #

Commercial 1 Track. Unit #2: Boilers

**************************************************************************

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas

DIVISION FINNED WATER-TUBE BOILERS

BuildingName The Description of the Project P DOCUMENTS

GASEOUS HYDROGEN SYSTEMS

mith Mills 4500A Smith Mills 4500A 4500A-3R OIL, GAS OR COMBINATION GAS/OIL COMMERCIAL BOILER/BURNER CAST IRON

mith Mills 3500A Smith Mills 3500A 3500A-3 OIL, GAS OR COMBINATION GAS/LIGHT OIL COMMERCIAL BOILER/BURNER CAST IRON

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

You can view our archived webinars by going to

Rental Boiler Specifications (Nebraska Boiler)

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.

Intelligent Heating for Your Home

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

AFUE 95% Heating Input 50,000 to 200,000 Btuh

MODEL CEW OHIO SPECIAL

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

HYDRONIC SOLUTIONS. More than just hydronic boilers, we offer the most efficient integrated hydronic solutions on the market.

JE Series Cast Iron Commercial Natural Gas Steam Boiler Submittal/Specifications

GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO.

FTIIIC-10. Domestic Hot Water Heaters and Boilers

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

A. Product Data: Include rated capacities, furnished specialties and accessories.

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications

Domestic Hot Water Heaters and Boilers FTIIIC-6

Commercial Boilers and Domestic Water Heaters APG-5

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

FINNED WATER-TUBE POOL HEATERS

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS

Packaged Marine Design Thermal Fluid (Hot Oil) Heaters

SERIES 19A. mith PRESSURIZED WET BASE

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

Transcription:

PACKAGED COMMERCIAL WATERTUBE BOILERS

PACKAGED COMMERCIAL WATERTUBE BOILER American Boiler Manufacturers Association 4001 N. 9 th Street, Suite 226 Arlington, VA 22203-1900 703/522-7350 2003, American Boiler Manufacturers Association, Inc.

FOREWORD This document was originally prepared by the Packaged Commercial Watertube Boiler Manufacturers Subcommittee of the Commercial Systems Group of the American Boiler Manufacturers Association. This update has been reviewed and editorially revised by the Commercial Systems Group for re-release. The contents are offered for information and as guidance only. The ABMA does not assume responsibility or liability for consequences arising from implementation or failure to implement the information or guidance contained herein. Also, the contents of this guide should not be construed as an endorsement by ABMA of any product or manufacturer.

THE PACKAGED COMMERCIAL WATERTUBE BOILER HISTORY Since its initial design in the latter half of the Eighteenth Century, the Watertube boiler has undergone a myriad of changes, all of which were essentially driven by the demand for higher capabilities, increased safety, and longer useful life. The early part of the Nineteenth Century saw the first use of boiler drums and defined water circulation. Higher-pressure requirements that appeared in the late Nineteenth Century led industry to move away from cast and wrought iron to steel. Development continued with the elimination of brick settings, the introduction of bent tubes and multi-drum units, the application of forced circulation technology, as well as the introduction of counter flow (flue gas to water) designs to maximize heat transfer and improve efficiency. Because there was divided responsibility in this earlier arrangement the industry was ready for the introduction of the Packaged Commercial Watertube Boiler (PCWT) unit. Modern Packaged Commercial Watertube boilers are engineered, constructed, and guaranteed in material, workmanship, and performance by one firm, with one manufacturer furnishing and assuming responsibility for all components in the assembled unit, such as burner, boiler, controls and auxiliaries. PCWT boilers are usually fire tested prior to shipment. DEVELOPMENT Most packaged Watertube boilers are the lineal descendants of the basic Nineteenth Century designs modified for packaged application. It is interesting to note that essentially all of Stephen Wilcox s (of Babcock & Wilcox) original twelve design rules that were established in 1875 still apply today. They are: Proper workmanship utilizing the best methods and simplest construction; The inclusion of a drop-out area (i.e. mud drum) for steam boilers to aid in accumulating and removing waterside impurities; Steam and water capacities large enough to preclude swings in pressure and/or water level; Adequate steam release space to prevent carryover and foaming; Proper circulation to maintain the metals at uniform temperatures; The division of water space into several sections to prevent a general steam explosion in the event that one section fails; Design with excess strength; Provide an adequate furnace to ensure complete combustion within the furnace proper; Provide for cross flow of the gases to the tubes to create turbulence and maximize heat transfer;

Provide easy access for cleaning and repairing; Maximize capacity and efficiency; Include the best accessories. Many different designs have evolved over the years. In today s market, however, the following designs predominate: Serpentine tube two drum type; Stay bolted firebox type with inclined tubes and water legs; D or O type; Straight tube box header; Coil Tube steam generators. These designs employ natural circulation (except coil tube) and have been continuously refined to improve boiler life and fuel utilization efficiency, while minimizing initial cost and maintenance. Furnace heat absorption and volumetric release rates continued to increase as engineering progress provided for improvements in heat utilization, better water circulation and better distribution and flow of the products of combustion. Units are rated in evaporation rate (pounds of steam per hour) or in British thermal units per hour (Btuh) output. Smaller units may be rated in boiler horsepower, or Btuh input. In the commercial Watertube markets, the unit is shipped completely assembled on a structural steel base and often includes the fuel-burning system and control plus selected auxiliaries. Improvements in fuel burning and control equipment have enabled manufacturers to offer more compact and efficient units. Burners are matched to the various furnace configurations to ensure compatibility, maximum efficiency and complete combustion. This matching, coupled with sensitive, sophisticated control systems has resulted in a significant reduction of air pollutant emissions. Standard designs are offered for gaseous fuels and for light fuel oils. Some designs are also available for burning residual oil and solid fuels such as coal or wood. With minor modifications these units can be fired with special fuels or used in wasteheat recovery projects.

MODERN PACKAGED WATERTUBE UNITS Evolution, advancing technology and customer demands have resulted in the present day packaged Watertube boiler. The Watertube design is employed in boilers from the very smallest used for residential heating through packaged units of 33,480,000 Btuh (1000 boiler horsepower) and greater. Packaged Watertube boilers have several features that recommend them to an end user. 1. Low radiant heat loss due to the design of the package. 2. Low water capacity resulting in quicker heat-up from a cold start 3. Compact design, which means a smaller footprint in the boiler room and lower headroom requirements. 4. The design of many Watertube boilers provides for natural circulation, which allows for large temperature differentials 5. High temperature / pressure capabilities. 6. Faster response to changing loads. Fuel burning and combustion control equipment have been continuously improved. A majority of packaged Watertube units utilize forced draft fans. An increasing number of the units are equipped with modulating control systems to match the firing rate to load demands as nearly as possible. Flame safeguard control systems are generally of the programming type and are frequently microprocessor-based. Such systems may include LED displays for self-diagnosis of system problems. Flame detectors have been improved and are matched to the unit. Since the various unit components complement each other the PCWT assemblies are quite compact and can be shipped complete with several auxiliary components. The only size restrictions are common carrier shipping clearance and weight restrictions. APPLICATION Packaged Watertube boilers are available in sizes from residential use to industrial applications of 35,000 lb/hr (1000 boiler horsepower).. They can be ordered for lowpressure steam or hot water application (ASME Section IV) or for industrial use at steam pressures of 700 psig and higher (ASME Section I) They are suitable for heating, both steam or hot water, or process application. The quick-steaming ability of the Watertube boiler makes it particularly suitable for process work where, because of its low residual water content, it is not necessary to have the boiler running during off hours or on weekend, or in cases where the demand varies widely. Watertube boilers, depending on size, may be fired by atmospheric gas burners, power gas burners, mechanical or air or steam atomizing oil burners, or combination gas/oil firing. Units to fire either natural gas or fuel oil may be arranged for either manual or

automatic fuel changeover. This versatility in firing arrangements allows the customer to decide on the mode of firing desired that best suits his needs. Control systems and fuel valve trains to meet the requirements of customers or various insurance or control codes are also available. These requirements include but are not necessarily limited to: American National Standards Institute (ANSI Z21.13) American Society of Mechanical Engineers (CSD-1) National Fire Protection Association (NFPA 85 2001) Underwriters Laboratories (UL 726 and/or 795) Factory Mutual (FM) Industrial Risk Insurers (IRI) The Watertube units are frequently tested and listed or labeled by nationally recognized testing laboratories such as AGA or UL as complying with an appropriate national standard, thus minimizing the work of the application engineer in determining compliance with specifications. The boiler vessel is constructed to comply with the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Power Boilers Section I, or Heating Boilers Section IV. The ASME Code Symbol is stamped on the boiler pressure vessel after testing and inspection by an authorized third-party inspector to insure compliance with the Code. Most boilers are stamped and registered with the National Board of Boiler and Pressure Vessel Inspectors (NBBI) in compliance with jurisdictional Requirements. ECONOMICS When analyzing the costs of various types of boiler systems the following should be carefully considered: Space requirements for PCWT units are frequently less than for other types due to their compact design and low head room the design requires. Tubes are normally removable in the normal access space provided around and between boilers and with certain types of coil or serpentine tubes, Code welding may not be required in a repair situation; No special foundations are required; The manufacturer of the completely assembled packaged boiler unit usually fire tests the assembled unit prior to shipment. This procedure assures the operational testing of all components. Fire testing may be performed at the boiler factory allowing the unit to be adjusted and set to approximate the field operating conditions, thus minimizing start-up costs.

The equipment is adjusted for maximum efficiency (80 to 85%) assuring minimum fuel consumption, thus reducing life-cycle costs; Normal unit life with proper maintenance and boiler water treatment may exceed that of other heating systems, again reducing life-cycle costs; The unit is fuel-flexible it can be ordered to burn a variety of fuels or to utilize electric energy thus the most economical fuel for the time can be selected; If the unit is not ordered equipped to burn a particular fuel it can be modified at modest cost should burning an alternate fuel become economically attractive; Due to standardization complete wiring and piping diagrams are available prior to equipment purchase; thus allowing the application engineer to design the entire system properly; The unit can be located anywhere from basement to penthouse to a remote location; Modern control systems can be arranged for remote monitoring of the unit; While some direct attention to the automatically controlled unit is required, it is minimal and training programs are available for personnel affected; Factory trained service technicians are available through the local unit distributor. Reduced steaming time from a cold start. High turndown (output) ratios are available for certain sizes of boiler. ADVANTAGES OF PACKAGED WATERTUBE BOILERS 1. Low maintenance 2. High pressure capabilities 3. Small size per Btu input 4. Knockdown units available for field assembly 5. More forgiving when it comes to large temperature differentials within the system 6. Fuel flexibility 7. Standard designs 8. Factory service available 9. Fast start-up CONCLUSION Summary of Characteristics 1. The heavy steel structural base distributes weight evenly on the boiler room floor; therefore, no special foundation is needed. 2. The units include a burner designed to match the boiler available for any grade of fuel oil, gas or combination gas-oil. 3. A totally enclosed and pre-wired control cabinet is mounted on the unit containing the latest electronic programming and flame failure safety controls. This control system may be microprocessor-based and can contain self-diagnostics. Operating controls, limits, interlocks, motor

starters and similar equipment wired and ready for electric service to be connected are included. 4. The owner can select the control system, from the very simplest to the latest self-checking microprocessor that best fits his requirements. 5. Forced draft designs require minimum stack to vent combustion gases. Low stack temperatures assure high operating efficiency. 6. The unit design provides gas-tight or neutral to negative firebox operation for added safety assurance. 7. Boiler pressure vessels constructed to the ASME boiler and Pressure Vessel Code, the ASME Code Symbol is stamped on the boiler pressure vessel after testing and inspecting by an authorized third party inspector to insure compliance with the ASME Code requirements. Most such boilers are stamped and registered with the NBBI. 8. Heavy lifting attachments are provided to facilitate positioning the unit. 9. Good internal water circulation provides better heat transfer. 10. The steel outer jacket over insulation protects the unit and provides a neat appearance. When thorough consideration of the above factors is taken, the packaged Watertube boiler meets every modern requirement for the generation of steam or hot water.