SERIES Commercial, Forced Draft, Hot Water or Steam Boiler Sizes from to,8 MBH output The right fit for any commercial job The Series is built to handle any installation - businesses, institutions, apartments, and other commercial buildings Available for use with gas, oil, or combination gas/oil fired in hot water and steam models Delivered in easily handled sections for convenience on the job site Series Features Cast iron sectional heat exchanger and push nipples Vertical flue design Easily assembled with short individual draw rods Optional tankless heater for domestic hot water Top or rear vent connections Side cleanout plates Optional Return Temperature Control (RTC) Ten sizes ranging from to,85 MBH output See back side for specifications VelocityBoilerWorks.com Philadelphia PA
Ten reasons why you need the Series commercial boiler. Optimum for large installations Available in ten sizes from,000 to,85,000 BTU/hr output.. Gas, oil or combination gas/oil fired Customer s preference in the choice of fuels for economy and availability may be an important part of the purchase decision.. Hot water or steam The Series has been designed to meet a wide variety of installations.. Tankless heater available for domestic hot water Convenient for small spaces or difficult installations that preclude a separate water heater. Finned copper coil heats water fast, and piping is easier to install. 5. Cast iron construction Cast iron heat exchanger sections and push nipples provide long life. Cast iron resists the effect of petroleum-based chemicals such as corrosion inhibitors, pump lubricants and antifreeze. Cast iron push nipples are important because they expand and contract at the same rate as the sections they join, which provides integrity to the entire assembly. 6. Convenient delivery in sections Delivery is available in easily handled sections that can be maneuvered through doorways and down stairs making this boiler ideal for installs where the boiler room is not readily accessible. 7. Easy assembly Once in place, the sections are easily assembled using a /-inch drive ratchet with a -/6-inch-deep socket and a wrench. Short draw rods pass through the sections reinforced lugs, resulting in fast, strain-free assembly. 8. Versatile venting options The Series is a forced draft boiler that eliminates the need for high chimneys or draft inducers. Uniquely, the boiler can be vented from either the top or rear for maximum installation flexibility. Rear outlet venting requires only 6-/ feet of vertical clearance from floor to ceiling. 9. Hassle-free maintenance All regular maintenance access areas are located on the left side, allowing the Series to be installed 9 inches from the right sidewall. Removable jacket panels and flue cover plates simplify access to the heating surfaces. 0. It s a! Satisfied customers are our goal. So, all boilers employ the latest technology for performance and safety. We offer a wide range of products to meet each customer s individual needs, and we offer competitive pricing, attractive warranties and optional extended coverage.
Top or rear flue outlet with adjustable lock-type damper includes tapping for outlet pressure readings Front mounted controls for easy adjustment and maintenance Left side jacket panels and cleanouts for easy access to all flue surfaces Tankless heater for domestic hot water Cast iron vertical flue design with pinned heating surface achieves maximum heat transfer Rear cover includes flame observation port and plugged tapping for over-fire draft readings Reinforced lugs and individual draw rods for easy assembly Wet base construction for improved circulation Burner mounting plate with flame observation port Your choice of a Beckett gas or oil burner Cast iron nipples ensure integrity of section assembly Standard Equipment All Boilers Sections unassembled, flush insulated jacket, burner mounting plate, burner adapter plate, rear flue damper (top outlet optional), flue canopy, rear observation port cover, target wall (S-0), and miscellaneous plugs, bushings and fittings. Steam Trim 5 PSI safety valve, L0A pressuretrol, gauge glass assembly, steam gauge. Water Trim 0 PSI safety relief valve, L006A high limit, pressure temperature gauge. Oil Boilers Flange mounted flame retention oil burner furnished with stage fuel unit, primary control and dual oil valves. Gas Boilers Flange mounted gas burner with standard controls meeting the latest UL requirements, dual gas valves and electronic ignition. Optional Equipment Top outlet flue damper, tankless heaters, 50 PSI relief valves (water), and combustion and hydronic controls to meet ASME CSD-.
Series Specifications MODEL HORSE- POWER GROSS OUTPUT (MBH) SQ. FT. STEAM AHRI NET RATING MBH STEAM MBH WATER OIL (GPH) BURNER INPUT GAS (MBH) THERMAL EFFICIENCY % WATER THERMAL EFFICIENCY % STEAM WATER CONTENT (GAL.) WEIGHT w/water (LBS.) GAS OIL GAS OIL STEAM WATER STEAM WATER VENT COLLAR DIA. (IN.) -0 0. 07 57 97.05 8 8.7 8. 80.0 8.5.5 66.0 9 68 7-0. 7 7 5 0.0 59 8.7 8. 80. 8. 5.0 75.0 8 995 7-05 8.9 6 98 76 55 5.50 79 8.7 8. 80. 8. 6.5 8.0 8 7 8-06.8 797 9 598 69 6.90 990 8.7 8. 80. 8.5 70.0 9.0 557 79 8-07 8.0 97 99 70 85 8.0 7 8.7 8. 80. 8.6 78.5 0.0 90 6 8-08.5 087 96 85 95 9.0 58 8.7 8. 80. 8.6 87.0.0 0 50 0-09 9. 6 6 995 8.0 6 8.7 8. 80. 8.7 95.5 0.0 676 880 0-0 5.0 505 788 9 09.00 867 8.7 8. 80. 8.7 0.0 9.0 08 57 0-50.5 690 59 0 70.60 09 8.7 8. 80. 8.7.5 8.0 6-55. 85 598 6 60 6.00 0 8.7 8. 80. 8.7.0 7.0 79 50. Trim suffix S = Steam Boiler W = Water Boiler Fuel suffix N = Natural Gas O = Oil. I=B=R net ratings shown are based on piping and pick-up allowances which vary from. to.89 for steam and.5 for water. Consult manufacturer for installations having unusual piping and pick-up requirements, such as intermittent system operation, extensive piping systems, etc. The I=B=R burner capacity in GPH is based on oil having a heat value of 0,000 BTU per gallon.. Firebox volume does not include added volume of 8 extended burner mounting plate (BMP). If 8 BMP is specified (refer to Figure ), add 0.7 cu. ft. to volume listed above.. Boiler ratings are based on.5% CO (oil) and 9.7% CO (natural gas), +.0 (inches) water column pressure at boiler flue outlet. Ratings shown above apply at altitudes up to 000 feet on oil and,000 feet on gas. For altitudes above those indicated, the ratings should be reduced at the rate of % for each 000 feet above sea level. Maximum Allowable Working Pressure: Steam Boiler 5 PSI, Water Boiler 80 PSI (US) - 5 PSI (Canada) Standard Safety (Relief) Valve Set Pressure: Steam Boiler 5 PSI, Water Boiler 0 PSI Beckett Gas Burners (Natural Gas) Crown Min. Inlet Gas Boiler Burner Rate STD. Motor Pressure Train Model Model Control Voltage H.P. (in W.C.) Size -0 CG0.S On/Off 0/60/ /. -0 CG0.S On/Off 0/60/ /.6-05 CG0.5S On/Off 0/60/ /. -/ -06 CG0.6S On/Off 0/60/ /. -/ -07 CG5.S Lo/Hi/Lo 0/60/ /.0 -/ -08 CG5.S Lo/Hi/Lo 0/60/ /. -/ -09 CG5.S Lo/Hi/Lo 0/60/ /. -/ -0 CG5.S Lo/Hi/Lo 0/60/ /.9 -/ - CG5.S Lo/Hi/Lo 0/60/ /.9 -/ - CG50.S Lo/Hi/Lo 08-0/60/.9 -/ Beckett Oil Burners Crown Boiler Boiler Burner Rate STD. Motor Model Model Control Voltage H.P. -0 CF500 On/Off 0/60/ / -0 CF800 On/Off 0/60/ / -05 CF800 On/Off 0/60/ / -06 CF00 Lo/Hi/Lo 0/60/ / -07 CF00 Lo/Hi/Lo 0/60/ / -08 CF00 Lo/Hi/Lo 0/60/ / -09 CF00A Lo/Hi/Lo 0/60/ / -0 CF00A Lo/Hi/Lo 0/60/ / - CF500 Lo/Hi/Lo 0/60/ - CF500 Lo/Hi/Lo 0/60/ Minimum gas pressures shown are for standard burners only. See manual for minimum gas pressure when other size gas trains are used. AVAILABLE FROM Specifications are subject to change without notice. CRN: A50.C S - 0/6 PN 9805
8 Series Dimensions (in inches) MAXIMUM FLUTE BURNER BECKETT APPROX. NUMBER NUMBER NUMBER OF OUTLET MOUNTING K.D. BLR. OF OF STEAM HEATERS DIAMETER PLATE WIDTH CF OIL CG GAS SHIPPING MODEL SECTIONS B RISERS C D E F G H H WEIGHT LB. -0 8-/ 9-/8 7 8 9-/ 0-7/8 6-0 -/ 8 -/8 7 8 -/ -5/8 675-05 5 0-/ 5-/8 8 8 -/ -5/8 987-06 6 6-/ 0 8-/8 8 0-5/8-5/8 7-07 7 -/ 6 -/8 8 0-5/8 8-5/8 589-08 8 8-/ -/8 0 0-5/8 8-5/8 90-09 9 5-/ 8 7-/8 0 -/8 9-/8 8-0 0 60-/ 5 0-/8 0 -/8 9-/8 6-66-/ 60 -/8-5/8 9-/8 95-7-/ 66 0 6-/8-5/8 9-/ 5 8 B 8 SAFETY/RELIEF VALVE C BREECHING PRESSURE SENSING; /8-6 PLUGGED (REAR OUTLET) 6 (TYP) F O.D. COLLAR (STD. REAR OUTLET) TOP VIEW BREECHING PRESSURE SENSING; /8-6 PLUGGED (TOP OUTLET) BREECHING PRESSURE SENSING; /8-6 PLUGGED (REAR OUTLET) 9 D INSULATED JACKET COMBINATION 8 F O.D. COLLAR (OPTIONAL TOP OUTLET) COMBINATION ASME DATA TEMPERATURE CONTROL REAR FLUE OUTLET W/ DAMPER NWL HIGH PRESSURE LIMIT CONTROL/MR RATING ASME DATA HIGH PRESSURE LIMIT CONTROL/MR OPERATING LIMIT OPERATING LIMIT REAR OBSERVATION PORT COVER OVER-FIRE PRESSURE SENSING; NPT PLUGGED 8 7 8 6 8 REMOVABLE SIDE PANELS Tankless Heater Ratings in GPM NUMBER OF TANKLESS HEATERS INSTALLED MODEL -0 6.75-0 7.5-05 7.5-06 7.5 5-07 7.5 5-08 7.5 5-09 7.5 5.5-0 7.5 5.5-7.5 5.5-7.5 5.5 0 Continuous draw heated from 0 F to 0 F with 00 F boiler water. TANKLESS HEATERS ( E MAXIMUM ALLOWABLE) 6 (TYP) LEFT SIDE VIEW (STEAM) IN IN G H BURNER MOUNTING PLATE 57 TWO HEATER MANIFOLD MM#67 LWCO LOWEST PERMISSIBLE WATER LEVEL PLATE (STEAM ONLY) FLOOR IN OUT 6 STD. FOUR HEATER MANIFOLD 6 5 8 FRONT VIEW (STEAM) GUAGE GLASS SET Multi-Heater Manifold THREE HEATER MANIFOLD OUT STEAM GUAGE RATING FLAME OBSERVATION PORT TEMPERATURE/ PRESSURE GUAGE ( PLACES) OUT 5 (TYP) MIN FOR JACKET REMOVAL FRONT VIEW (WATER) INSTALLER/ SERVICE PROBE TYPE LOW WATER CUT-OFF l Not supplied as standard equipment ITEMS DESCRIPTION -/ Copper Elbow -/ x -/ x -/ Copper Tee x -/ x -/ Copper Tee x x -/ Copper Tee 5 -/ Copper x MIP Adapter. It is important that tankless heater sections be correctly located in the boiler. Refer to installation manual.. Pressure drop across each T- tankless heater = 5.5 PSI at 7.5 GPM flow rate.. Locate heater control in heater identified as
Burner Mounting Plates and Adapter Plates BECKETT ( CF SERIES) BURNER ADAPTER PLATE I.D. B C MODEL PART NO. NO. DIA. DIA. REF. -0 THRU -05 000 90 -/ 0 7-/6-06 THRU -08 00 9 6-/8 0 7-/6-09 THRU - 00 9 6-/ 0 7-/6 BECKETT ( CG SERIES) BURNER ADAPTER PLATE I.D. B C MODEL PART NO. NO. DIA. DIA. REF. -0 THRU -06 000 90 -/ 0 7-/6-07 THRU -08 00 9 6-/8 0 7-/6-09 THRU - 00 9 7-/ 0 7-/6-00 9 8-/8 0 7-/6 Note:. A burner adapter plate is needed for each boiler. Control Tappings TAPPING SIZE LOCATION (IN.) STEAM WATER A Supply Supply B Plug (-0 thru -06) Supply (-07 thru -) Plug C Blow-Off Valve Return D Return Plug (-0 thru -) Return (-) E Plug Blow-Off / Drain Valve F Plug Plug G -/ Safety Valve / Surface Skim Tap Relief Valve J Plug Plug J Float L.W.C.O. Plug K / Plug Probe L.W.C.O. M / Operating Pressure Limit Control Operating Temperature Limit Control N / Hi Pressure Hi Temperature Limit Control / Manual Reset Limit Control/Manual Reset P / Gauge Glass/#67 L.W.C.O. Plug Q / Steam Gauge (Bush to / ) Temperature/Pressure Gauge (Bush to / ) S / Tankless Heater Control Tankless Heater Control T / Firing Rate Pressure Control Firing Rate Temperature Control B DIA BOLT CIRCLE C (REF) J A J B 8 P T DIA HOLE N M G IDENTIFICATION NUMBER STANDARD BURNER ADAPTER PLATE STANDARD 8 EXTENDED FRONT VIEW SIDE VIEWS CAST IRON BURNER MOUNTING PLATES S P J Q K J Series Minimum Piping Recommendations Water Boiler Impact of System Piping Many hot water systems are zoned. Some also use mixing valves to control the water temperature in the system. These features can cause the flow through the boiler to vary dramatically, depending on the status of the zones or mixing valves. In addition, the large water content of many commercial systems has the potential to subject the boiler to operation with low return temperatures for an extended period of time. These factors can shorten the life of a boiler due to thermal shock or flue gas condensation. Crown s Recommendations On the following pages, provides three basic recommendations for near-boiler piping that are intended to maximize the life expectancy of the boiler by protecting it from flue gas condensation and thermal shock. Each protects the boiler by making sure that both of the following conditions are met: n The flow through the boiler is high enough to ensure a temperature rise of less than 0 F F FRONT VIEW E BACK VIEW n The return temperature does not fall below 5 F for an extended period of time. RTC Return Temperature Control Piping Recommendation makes use of s optional RTC (Return Temperature Control). This control provides an economical and effective way of protecting the boiler from thermal shock and condensation. It can be incorporated into most hot water systems with minimal modifications to the system design and operation. When this option is used on multiple Series s, one RTC is required for each boiler. The RTC is also available with an outdoor reset option. This provides additional energy savings by modulating system water temperature to match the building load requirements. D C
Series Minimum Piping Recommendations Water Boiler Recommendation is used when the load is constant and not varied due to mixing or multiple zones. Use when: n system return water is not less than 5 F for prolonged periods of time n system flow does not impact flow through the boiler x NIPPLE AND BELL REDUCER -0 THRU - (W/0 F DROP) -0 THRU - (W/0 F DROP) - (W/0 F DROP) A HEADER B BRANCH Recommendation is a primary-secondary piping method that maintains a constant flow through the boiler by using a secondary boiler circulator. This arrangement isolates the boiler from flow variations but does not safe-guard against cold return water temperatures. Use when: n system return water is not less than 5 F for prolonged periods of time n system flow does not impact flow through the boiler (i.e. zoning, mixing) CIRCULATOR SYSTEM PUMP MAX D TEES x NIPPLE AND BELL REDUCER CIRCULATOR SYSTEM PUM PIPE SIZING AND NOTES FOR RECOMMENDATIONS AND PIPING SIZE (IN) PIPING HEADER BRANCH SIZE (IN) () () (A) (QTY.) SIZE (B) 0 F 0 F 0 F 0 F 0 F 0 F MODEL DROP DROP DROP DROP DROP DROP -0 -/ -/ -0 -/ MAX -/ D SYSTEM PUMP -05 -/ -/ TEES -06 -/ -/ -/ -/ -07 -/ -/ -08 -/ CIRCULATOR (BY OTHERS - SEE -/ NOTE 5) -09-0 -/ (SEE NOTE ) -/ - -/ -/ - -/ -/ (). All piping is schedule 0.. Pipe sizes listed are based on a 0 F or 0 F differential (temperature drop). Select one to match application.. When specified return piping is less than, install x nipple and appropriate size bell reducer directly into boiler return tapping as shown.. Drain valve ball valve preferable, gate valve acceptable alternative (supplied by others). Minimum valve size per ASME code is / NPT. x NIPPLE AND BELL REDUCER CIRCULATOR SYSTEM PUMP -0 THRU - (W/0 F DROP) -0 THRU - (W/0 F DROP) B BRANCH -0 THRU - (W/0 F DROP) -0 THRU - (W/0 F DROP) - (W/0 F DROP) MAX D TEES D HEADER A RE
Recommendation is used when the return water temperature goes below 5 F for prolonged periods of time. This is also primary-secondary piping, but includes the addition of a -way valve, return water sensor and boiler-mounted RTC Return Temperature Control. PIPE SIZING AND NOTES FOR RECOMMENDATION DIVERTING VALVE & ACTUATOR CIRCULATOR -0 THRU - (W/0 F DROP) -0 THRU - (W/0 F DROP) PIPING SIZE (IN) SYSTEM PIPING HEADER BRANCH SIZE (IN) () () (A) (QTY.) SIZE (B) 0 F 0 F 0 F 0 F 0 F 0 F MODEL DROP DROP DROP DROP DROP DROP -0 -/ -/ -0 -/ -/ -05 -/ -/ -06 -/ -/ -/ -/ -07 -/ -/ -08 -/ -/ -09-0 -/ -/ - -/ -/ - -/ -/ () SYSTEM PUMP MAX D TEES D SEE NOTE 5 SEE NOTE 6 x NIPPLE AND BELL REDUCER SENSOR (SEE NOTE 7) DIVERTING VALVE & ACTUATOR CIRCULATOR SYSTEM PUMP B BRANCH - (W/0 F DROP) TEES D HEADER A SENSOR (SEE NOTE 7). All piping is schedule 0.. Pipe sizes listed are based on a 0 F or 0 F differential (temperature drop). Select one to match application.. When specified return piping is less than, install x nipple and appropriate size bell reducer directly into boiler return tapping as shown.. Drain valve ball valve preferable, gate valve acceptable alternative (supplied by others). Minimum valve size per ASME code is / NPT. 5. Maximum linear feet of pipe from -way bypass port to sensor location = feet. Bypass line shall be the same diameter as return A. 6. Minimum linear feet of pipe from point of mixing (where bypass meets return line) to sensor location = feet. 7. Install special x nipple with / NPT side tapping closest to boiler. Where applicable, use bell reducer to adapt to recommended return pipe size. 8. Proper boiler circulator sizing is listed in RTC literature. MAX D SEE NOTE 5 SEE NOTE 6 Series Minimum Piping Recommendations Steam Boiler 8 MIN. B 8 MIN. RISER (SEE NOTE 5) (SEE NOTE 5) B RISER (SEE NOTE 5) (SEE NOTE 5) 8 MIN. B RISER (SEE NOTE 5) (SEE NOTE 5) (SEE NOTE 5) MIN. (SEE NOTE 5) MIN. (SEE NOTE 5) SEE NOTE MIN. WATER LINE HEADER SEE NOTE TO BLOW-OFF/ WATER LINE HEADER EQUALIZER (SEE NOTE TO ) BLOW-OFF/ CLOSE NIPPLEQUALIZER SEE NOTE WATER LINE HEADER HARTFORD LOOP CLOSE NIPPLE TO BLOW-OFF/ -0 THRU -06-07 THRU - (REQ D ON GRAVITY EQUALIZER (SEE NOTE HARTFORD ) LOOP SYSTEM) -0 THRU -06-07 THRU - (REQ D ON GRAVITY CLOSE NIPPLE SYSTEM) HARTFORD LOOP -07 THRU - (REQ D ON GRAVITY (WET ) - SYSTEM) (WET ) - -0 THRU -06 RISER PIPING SIZE (IN) SPACING (IN) RISER HEADER (QTY.) & EQUALIZER MODEL SIZE () () () () B -0 () -/ -0 () -05 () -06 () -/ -/ -07 () 6 -/ -/ 6-08 () 6 -/ -/ -09 () 6 -/ -/ 8-0 () 6 5 - () 6 60 - () 6 0 6. All piping is schedule 0.. To prevent condensate from being trapped in header, do not reduce equalizer elbow at header connection.. Drain/blowoff valve ball valve preferable, gate valve acceptable alternative (supplied by others). Mininim valve size per ASME code is / NPT -0/-05; NPT -06/-0; -/ NPT -/-. Increasing the valve size will improve the blowdown operation In all cases, piping connection blowoff valve to boiler should be full size to the point of discharge.. For pumped return systems, see Series installation manual. - (WET )