AGUAdensT TM 100% commercial condensing D.H.W. commercial water heaters from 70 to 280 kw AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Similar documents
AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

MYdens T 5WARRANTY 1:20. Ti TITANIUM. commercial gas condensing boilers. boilers from 60 to 280 kw AISI 316 YEARS WORKING PRESSURE HEAT EXCHANGER

MADE IN ITALY. Quality makes the difference. For 50 years. Product Guide

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

1 VICTRIX ZEUS Superior kw I features

ENERGY TOP. Condensing boiler solutions

white blue cobalt bordeaux light oak (rovere)

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Ciao Green Condensing Wall-Hung Boilers

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

Exclusive Green E Condensing Wall-Hung Boilers

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

SPECIFICATIONS - NIKE

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

CONDEXA PRO EXCELLENCE AND VERSATILITY

The iqe Boiler Range. Combination and System T Boilers.

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Bluehelix Tech RRT Wall-hung condensing boiler with Ferroli Thermobalance heat cell

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

Mynute Green Condensing Wall-Hung Boilers

Condensing, pre-mixed, wall-hung gas boilers with water tank

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

USERS MANUAL FOR GAS BOILERS

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A

MODULAR GAS CONDENSING UNIT EQUIPPED WITH PRIMARY RING and premix modulating Low NO x. from 100 to 900 kw and in battery up to 8 units

Rapid. Suspended Warm Air Heater. Caring for the environment!

Power X High Power Condensing Wall-Hung Boilers

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

The mechatronics of EVE 05

C Tahiti. condensing

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

Since 1983 Nuova COTERM has developed a wide range of water heaters.

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Power X High Power Condensing Wall-Hung Boilers

THE PERFECT CONDENSATION

CITY OPEN - CITY BOX from 25 to 35 kw

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Seradens Super Seradens Super Plus

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

Sirius FS. Working towards a cleaner future

CONDENSING HIGH EFFICIENCY BOILERS

COND SYSTEM Condensation boiler outdoor / indoor combined with indoor heaters

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

GAS-FIRED FLOOR-STANDING BOILERS

GAS ABSORPTION HEAT PUMP

ACCUMULATION OF EUROPEAN CLASS

White paper: New Ecodesign rules and energy labelling for space and water heaters

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

PCH/new Series. High performance, total flexibility

Tower Green HE Hybrid

BWA. CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Compact HRE Boiler Range. The smart choice for heating and hot water

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

CAMUS. two-pass counter flow fire tube commercial boilers. for hydronic heating and hot water supply TURNDOWN RATIO! HYDRONICS LTD. Rev.

LOW NOx MODULATING GAS BURNERS

CAST IRON ATMOSPHERIC BOILERS

WHE 2.24 / WHE 2.24 FF

Installation, Operating and Servicing Instructions

STOKVIS R40 EVOLUTION RANGE. High Efficiency Fully Condensing Ultra Low NOx Wall Mounted Gas Fired Boilers

TABLE OF CONTENTS BRADFORD WHITE BOILERS

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

KDE. PRESSURIZED STAINLESS STEEL CONDENSING BOILER FROM 124 kw TO 2160 kw

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Ideasandformsinevolution

Wall hung combination

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Bluehelix Tech Wall-hung premix condensing boilers, only heating or instant combi operation

SGE Condensing Gas - Solar Water Heater

HIGH OUTPUT. Skin design RANGE

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

Sirius WH. Working towards a cleaner future

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

HIGH EFFICIENCY COMMERCIAL BOILERS

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

Gas condensing boiler UltraGas

PRODUCT GUIDE 2018/19 ACV HEATING AND HOT WATER SPECIALISTS

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER

FORMENTERA KC - KRB - KR

Installation, Operating and Servicing Instructions

Transcription:

MADE IN ITALY commercial condensing D.H.W. up to 11 bar WORKING PRESSURE AISI 316 Ti TITANIUM D.H.W. 0% CONDENSING AGUAdensT TM commercial water heaters from to 80 kw

TTM CONDENSING HOT WATER THE NEW GENERATION OF COMMERCIAL GAS CONDENSING WATER HEATERS AGUAdens T from to 80 kw is the new range of modulating commercial gas condensing water heaters, completely patented and assembled by Cosmogas. INNOVATIVE DESIGN, COMPACT, POWERFUL, LIGHTWEIGHT AGUAdens T are designed to be space-saving ; thanks to their vertical structure they allow to save space in both new and to renovate thermal power plants. They supply water in continuous up to 1 l/min ( t 5 C). Thanks to their lightness they are easy to carry and to place inside thermal power plants. MONOBLOCK MODULARITY AND CONTINUITY Each commercial water heater is composed of 1 to 4 R.V.C. kw heat exchangers: a monoblock system that optimises the supplied output according to real D.H.W. needs ensuring maximum efficiency. The presence of more heat exchangers always guarantees continuity of service in case of maintenances or breakdowns. AISI 316 Ti (Titanium) STAINLESS STEEL HEAT EXCHANGER The only primary heat exchanger able to work in direct contact with chlorinated mains water. Each R.V.C. heat exchanger is made without weld joints and it is able to bear a working pressure up to 11 bar. ECOLOGIC PREMIX BURNER The whole range of commercial water heaters is equipped with ecologic premix burners made of Fecralloy metal fibre. MAXIMUM EFFICIENCY EVEN WITH SMALL FLOWS -way motorized valves are available among accessories. They allow high seasonal efficiency in systems characterized by frequent and high output variations. AGUAdens floor standing 180 - - 80 kw

AGUAdens T TM Why choose AGUAdens T: Savings and efficiency Condensing technology Total flame modulation Certified efficiency up to 7% Suitable water flow to heat exchangers with optional -way motorized valves Cascade sequence control and heat exchanger rotation Comfort Silent Easy installation and maintenance Reduced size and weight Construction quality Modern, innovative and attractive design AISI 316 Ti stainless steel R.V.C. heat exchanger Turndown ratio up to 1:0 Ecology Fecralloy fibre premix burner Reduced gas emissions in the atmosphere CO<15 ppm and NOx<15 ppm floor standing - 0-115 - 1 kw up to 11 bar WORKING PRESSURE AISI 316 Ti TITANIUM D.H.W. 0% CONDENSING 3

A HEART OF TITANIUM PATENTED AISI 316 Ti (TITANIUM) STAINLESS STEEL R.V.C. PRIMARY HEAT EXCHANGER PATENTED EXCLUSIVE DESIGN - R.V.C. heat exchanger, heart of AGUAdens T system, is the result of research and intensive testing together with Cosmogas experience that, for years, has been designing and patented heating and domestic hot water production systems. EXCEPTIONAL RESISTANCE AGAINST CORROSION - The 3 series of AISI 316 Ti (TITANIUM) stainless steel round tubes, which the R.V.C. heat exchanger is made of, are fasten without weld joints to keep stainless steel characteristics unaltered and to grant the highest resistance against corrosion from mains water that sometimes contains a high percentage of chlorine, necessary for the purifying treatment. HIGH EFFICIENCY - R.V.C. has been designed to reach an optimal exchange along the entire length of the exchanger and to grant an exceptional efficiency up to 7% with savings up to 30%. R.V.C. - TECHNOLOGY MADE IN COSMOGAS The R.V.C. heat exchanger is made of 3 series of round tubes (18 and 16 mm diameter), to avoid clogging and to grant: LARGE WATER FLOW GREAT EXCHANGE SURFACE LOW PRESSURE DROPS HIGH WORKING PRESSURE (up to 11 bar) 4

AGUAdens T TM ECOLOGIC PREMIX BURNER Ecologic premix commercial water heaters have a constant air/gas ratio in each point of the turndown range of the burner, decreasing polluting emissions and optimising efficiency. The premix burner is made of Fecralloy a special metal fibre and has a round shape. Cosmogas ecologic premix burner spreads short and perfectly nourished flames. ADVANTAGES: High-efficiency combustion Low polluting emissions (CO<15 ppm and NOx<15 ppm) Natural gas and LPG operating THE ONLY PRIMARY HEAT EXCHANGER ABLE TO WORK IN DIRECT CONTACT WITH MAINS WATER Cosmogas is the only manufacturer who can offer a Titanium primary heat exchanger that can be directly supplied by mains water guaranteeing a great resistance to the corrosion and the aggressiveness of chlorinated waters. Thanks to low inlet temperatures the R.V.C. exalts the condensing effect and supplies D.H.W. even at high temperatures, maximizing savings and reducing to minimum the thermal inertia PREMIX BURNER COSMOMIX PATENTED PREMIX SYSTEM The innovating premix system employed in AGUAdens T condensing commercial water heaters allows an exceptional turndown ratio of 1:0 (AGUAdens 80 T) The variable circulation of the fluid allows a flue gas/water upstream thermal exchange, this sets up a high efficiency that quickly leads to flue gas condensing. During the operating, input cold water is distributed on Ø16 and Ø18 mm round tubes series. The advantage of such a system is to utilise the condensing effect and get better outputs. 5

COSMOGAS SYSTEM WORKS ALWAYS IN CONDENSING MODE EFFICIENCY ALWAYS GUARANTEED IN CONTINUOUS AND PEAK PERIODS The innovative design of AGUAdens T, instantaneous commercial water heater, combined with AGUAtank, storage tank constitutes a perfect semi-rapid system that can provide hot water exactly when needed. AGUAdens T, produces continuous D.H.W. which adds to AGUAtank storage, allows the production of D.H.W. availability during peak periods. All advantages of a commercial instantaneous water heater combined with all the benefits of the storage to meet any water need. AGUADENS T + AGUATANK SYSTEM PERFECT SEMI-RAPID To optimise AGUAdens T performance, Cosmogas has designed AGUAtank, an inertial D.H.W. storage tank (1-00 - 300-0 - 7-00 litres capacity) in this way the system always guarantees: D.H.W. constant and stable temperature even in case of small withdrawals Higher availability of domestic hot water during peak period withdrawals Limited ignitions of the burner in presence of small withdrawals, protecting the environment and guaranteeing a further saving The system satisfies both peak periods and continuous D.H.W. needs. 6

CONDENSING D.H.W. THE ACTUAL ENERGY SAVER AGUAdens T TM New energy saving legislation and modern residential and commercial building insulation techniques, have significantly reduced heating needs, and it s going to decrease. With the diffusion of high performance showers, cascade showers, Jacuzzis, wellness and fitness centres, hot water usage is increasing as much as fuel consumption for its production. If we consider that hot water is used 365 days a year and at all latitudes, to save upon hot water production has become a priority, above all in tertiary sector with high water needs. ALL THE ADVANTAGES OF DIRECT EXCHANGE: AGUADENS T WORKS ALWAYS IN CONDENSING MODE If we compare any D.H.W. production system, from the traditional semi-rapid one to that with both internal and external heat exchanger it can be noticed that thermal exchange always happens in two phases: hot water heating in the primary heat exchanger of the water heater and further thermal exchange between the water of the primary circuit and the sanitary water (fig. 1, ). When AGUAdens T is connected to AGUAtank, D.H.W. heating directly happens inside the primary heat exchanger (fig. 3). Therefore there are no inserted heat exchangers and the exchanged output is always the one given by AGUAdens T. This sets very fast charging and recovery times. For all these reasons AGUAtank storage tanks coupled to AGUAdens T are % smaller on average than capacities of storage tanks with coil or tank in tank, etc.. TRADITIONAL SEMI-RAPID SYSTEM No condensing Reduced efficiency due to double thermal exchange pumps to be installed Higher thermal loss A lot of ground space occupied 1 WATER TANK WITH INTERNAL HEAT EXCHANGER SYSTEM No condensing High recovery times Efficiency of the system bound to coil surface A lot of ground space occupied ADVANTAGES OF COSMOGAS SEMI-RAPID SYSTEM 3 It works always in condensing mode D.H.W. direct heating D.H.W. production uses all the power of AGUAdens T 1 connection and 1 pump only Reduced volume of the storage tank Reduced recovery times Less ground space occupied AGUAtank AGUAdens T 7

EFFICIENCY AND VERSATILITY SUITABLE FOR NEW AND RENEWAL OF THERMAL POWER PLANTS In many utilities, D.H.W. production systems consist of big storage tanks that, as well as promote proliferation of bacteria, they occupy a lot of ground space and are characterized by relevant energy loss and waste. According to actual needs of users, Cosmogas semi-rapid system, always allows the choice of proper balance between output and storage. AGUAdens T + AGUAtank semi-rapid system guarantees high performances even with extremely reduced storage (1 lt x kw) and thanks to its multi-burner setting, it can heat only the water needed without any waste, reducing consumption to the minimum. D.H.W. PRODUCTION ( t 5 ).000 lt/ AGUAtank 300 lt AGUAdens T 80 kw WHEREVER THERE IS THE NEED FOR A LOT OF D.H.W. AGUAdens T + AGUAtank semi-rapid system is simply perfect for any industrial or tertiary installation with high domestic hot water needs: Hotels Campings Flat buildings Restaurants and Cafeterias Schools Sport centres Wellness centres Hospitals Car washes Slaughterhouses Distilleries Tanneries Factories Farms COVER-BOX T SAFE AGAINST BAD WEATHER The AGUAdens T is available for use outdoors with the additional COVER-BOX T, the CE certified, fireproof, weather resistant cover made of anodized aluminium that provides an IP X5D electric protection degree. Its reduced size and elegant design make its placement easy. Possibility of remote control via 885IF 0-V interface. 8

AGUAdens T TM EXAMPLES OF APPLICATION WITH RENEWABLE ENERGY CONDENSING SEMI-RAPID SYSTEM WITH SOLAR PRE-HEATING 9 9 9 0 16 1 1 3 13 18 4 6 5 6 Max 1 metro 5 7 19 8 18 15 17 11 CONDENSING SEMI-RAPID SYSTEM WITH HEAT PUMP INTEGRATION 3 1 3 13 18 1 4 6 5 9 9 9 14 4 3 5 7 Max 1 metro 1 17 19 8 11 18 1 - AGUAdens T commercial water heater - Circulating pump 3 - D.H.W. supply from AGUAdens T 4 - Gas inlet 5 - AGUAdens T cold water inlet 6 - AGUAtank storage tank 7 - AGUAtank filling pump 8 - AGUAtank temperature sensor 9 - Sanitary users - Hydraulic safety group 11 - Cold water inlet 1 - Shut-off valve 13 - Safety kit 14 - Technical water storage tank 15 - Filling and safety solar group 16 - Solar panel 17 - Condensate drain 18 - Expansion vessel 19 - Pouring-off pump 0 - Solar control board 1 - Plate exchanger - 4 tubes heat pump 3 - Fan-coils 4 - Safety valve 5 - Thermostatic mixer The examples reported are merely indicative 9

STANDARD DETAILS THAT MAKE THE DIFFERENCE STANDARD CONDENSATE ACIDITY NEUTRALIZER Condensing water produced during the combustion process react to combustion products turning into acid water. To put down acidity, each AGUAdens T commercial water heater is standard equipped with a condensate acidity neutralizer, sized to restore the ph to tolerable values Content: kg of limestone CONDENSATE BLOCKED DRAIN SWITCH A special inner condensate cup, collects condensate and makes it flow freely to the drain; in the condensate cup is connected a blocked drain switch that cuts off the commercial water heater if the level of condensate exceeds the permitted limit. STANDARD WATER FLOW METER AGAINST SMALL FLOWS Each heat exchanger inside AGUAdens T is equipped with a standard flow meter to guarantee a more accurate management of the flows and to make the system operate in a more efficient way. STANDARD AIR FILTER AGUAdens T is equipped with a standard air filter to protect the burner, the combustion chamber and the heat exchanger from dust and impurities, ensuring a better efficiency of the combustion circuit. INTEGRATED FLUE BACK PREVENTER Each burner, inside AGUAdens T, has been standard equipped with a flue back preventer, on the combustion circuit, to prevent the possible flue gas recirculation among different exchangers, in case of cascade sequence installations.

AGUAdens T TM OPERATING SCHEMES 3 7 8 1 19 6 3 4 5 0 9 11 7 9 11 15 8 7 9 11 7 9 11 7 8 8 8 18 6 6 6 6 5 31 5 31 5 31 5 31 4 1 13 14 30 1 1 13 14 4 1 13 14 4 1 13 14 16 9 17 1 7 6 4 5 3 0 19 3 8 9 11 7 8 9 11 15 8 7 18 6 6 31 31 5 5 14 14 4 1 30 1 13 1 13 16 9 17 1 - Manager thermal unit - Air intake 3 - Flue gas outlet 4 - Dependent thermal unit 5 - Fecralloy metal fibre premix burner 6 - Fan 7 - Gas valve 8 - Hot water supply and safety temperature switch 9 - -way motorized valve - Water flow meter 11 - Cold water temperature sensor 1 - Flue gas temperature sensor 13 - High limit flue gas temperature switch 14 - Thermal unit condensate drain 15 - Water pressure sensor 16 - Blocked drain switch 17 - Condensate drain siphon 18 - Condensate acidity neutralizer 19 - Condensate drain 0 - Drain cock 1 - Cold water inlet - D.H.W. supply 3 - D.H.W. temperature sensor 4 - D.H.W. supply manifold 5 - Cold water manifold 6 - Automatic air vent cock 7 - Gas inlet 8 - Air filter 9 - Flue gas outlet pipe 30 - Blocked flue pressure switch 31 - Flue back preventer IT GETS THROUGH A 65 cm WIDE DOOR AGUAdens T represents the best balance between power, weight and size. Being extremely compact it gets through a 65 cm wide door, allowing easy access into thermal power plant. Thanks to its light weight it is possible to easily handle it even in case of difficult installations. ADJUSTABLE FEET FOR PROPER ALIGNMENT AGUAdens T is equipped with a series of adjustable feet for proper alignment of the commercial water heater. The height of the feet varies from 0 to mm. 11

EVERYTHING UNDER CONTROL STANDARD CONTROL DEVICE FOR PERFECT OPERATING OF THE INSTALLATION The control board of the commercial water heater allows the management of: Sanitary circuit pump Output proper modulation Pump unlock system Auto diagnostic of all components and functions: visualization of errors and lockouts, temperature sensors, ionisation current, fan rotation speed, water flow rate, water pressure Antifreeze device Low water flow protection Low water pressure protection Flue blocked pressure switch Condensate blocked drain switch AGUADENS CONNECTION TO AGUATANK 1 - Commercial water heater AGUAdens T - 0 T - 115 T - 1 T - Safety Kit 3 - Circulating pump 4 - Condensate acidity neutralizer 5 - Hot water tank drain 6 - Cold water inlet 7 - Safety valve 8 - Hot water tank expansion vessel 9 - D.H.W. supply - Anodic protection 11 - AGUAtank hot water tank 1 - Condensate drain The examples reported are merely indicative 1

TELE MANAGEMENT AND MODBUS PROTOCOL AGUAdens T TM AGUAdens T can be equipped with: 885IF (optional) interface that allows the control of boilers through 0-V analog signal or MODBUS digital signal or dedicated interface, that can be integrated to all devices with LonWorks or BACnet protocol Suitable for commercial, industrial and apartment solutions. The installer or service company can then configure, monitor and remotely control the entire operation of the commercial water heater, helping to reduce energy consumption and at the same time lowering the cost and frequency of maintenance. SIMPLE AND INTUITIVE CONTROL PANEL Control panel with digital back-lighting display for an easy and intuitive visualization of parameters, boiler phases, error messages, with electronic temperature control. Display back-lighting turns off after 5 minutes of inactivity (SAVE ENERGY). SANITARY CIRCUIT PUMP REGULATION AGUAdens T control board, besides the handling of the sanitary circuit pump, allows the visualization of the water flow in l/min and sets the correct water speed according to the hardness (see page 16), preserving the integrity of the heat exchanger and the perfect efficiency of the system. EASY ELECTRIC CONNECTIONS AGUAdens T is equipped with a pre-wired terminal box with connectors and clear symbols, ready for an easy connection to each installation component like sensors, pumps and control boards. Next to the terminal box there is the 885IF interface set up that allows a 0-V input. 13

UP TO 535 l/min D.H.W. AGUAdens T CASCADE SEQUENCE 885HC SEQUENCER UP TO 4 AGUAdens 80 T - AGUAdens 80 T water heaters can be connected in cascade sequence up to 4 units to achieve a maximum power of 1176 kw. One unit operates as Manager and the other as Dependents modulating to get the requested output. 000 0 896 380 1880 MINIMUM GROUND SPACE - can1300 be connected 0 0 with to each other in cascade sequence a0minimum distance of cm. They have been designed to have access to both front and rear side, to facilitate any type of maintenance. 000 15 0 MAXIMUM D.H.W. SUPPLY - 4 units in cascade sequence provide up to 535 l/min at t 30 C domestic hot water. 0 896 0 380 15 184 0 CASCADE SEQUENCE 184 0 CONTROL 0 AGUAdens 80 T cascade sequence is controlled by a 885HC sequencer that manages the rotation and the sequence. Each water heater must be equipped with a 885IF interface. AGUAdens 80 T cascade sequence is possible through a simple daisy0 chain wiring 0 connection. Safet kit 0 433 0 3 0 17,5 17,5 14 1190 11 3 184 0 1580 0 11 1530 Depending on local code, it is useful to install a safety kit on each unit. 184 0 0 3 SAFETY KIT

AGUAdens T TM WIDE RANGE OF ACCESSORIES ON DEMAND Each AGUAdens T gas condensing water heater can be equipped with one or more of the following accessories on demand: AISI 316L stainless steel safety kit complete with shut-off gas valve(suitable for D.H.W.) Variable inverter pump Polypropylene flue gas outlets SAFETY KIT COMPLETE WITH SAFETY DEVICES UP TO 1 kw STAINLESS STEEL AISI 316L E A - D.H.W. supply 1"1/ B - Gas inlet 1" C - Cold water inlet 1"1/ D - Condensate drain Ø8 mm E - Safety kit complete with shut-off valve B A C D SAFETY KIT COMPLETE WITH SAFETY DEVICES UP TO 80 kw STAINLESS STEEL AISI 316L E B A C D A - D.H.W. supply DN 65 PN 16 B - Gas inlet 1"1/4 C - Cold water inlet DN 65 PN 16 D - Condensate drain Ø8 mm E - Safety kit complete with shut-off valve SAME FLUE SYSTEM FOR AGUADENS T AND MYDENS T UNI 1158 legislation allows the connection of two appliances with similar characteristics in the same flue system even if they serve different installations. It is therefore possible to combine a condensing water heater AGUAdens T to a condensing boiler MYdens T connecting them in the same flue system. In this way both appliances can be dimensioned according to real domestic hot water needs (AGUAdens T) and heating needs (MYdens T) optimising performances and exalting the condensing effect in both installations. AGUAtank AGUAdens T MYdens T 15

GUARANTEED EFFICIENCY WATER SPEED AND ANTI LIMESTONE FUNCTION To maintain the maximum efficiency of AGUAdens T water heater it is fundamental to guarantee a certain speed of the inlet water inside the R.V.C. heat exchanger. To assure this a load pump is needed to regulate the correct water flow according to inlet water hardness, as shown in the diagram below. The control panel allows the visualization of water flow in l/min and sets the correct speed according to the hardness. For instance if mains water supplies AGUAdens 80 T with a hardness equal to about 5 f, the water heater will demand a minimum water flow of 13,5 m 3 /h. DIAGRAM FOR PUMP SELECTION ACCORDING TO WATER HARDNESS Water hardness (ppm) T 0T-115T-1T 180T-T 80T MINIMUM FLOW MAXIMUM FLOW HARD WATER over 31 f (308 ppm) SOFT WATER from 13 to 31 f (137 to 308 ppm) Water flow (m 3 /h) 16

AGUAdens T TM VARIABLE CIRCULATION MODULATING PUMP WITH STAINLESS STEEL BODY AGUAdens T advanced electronics allow the commercial water heater to direct manage the inverter pump, with stainless steel body, of the primary circuit (available on demand) that combined with -way motorized valves guarantees the perfect balance between heat output and heat input, maximizing gas condensing. MAGNA 1 3-0 (Grundfos) INVERTER PUMP MAGNA 1 - (Grundfos) INVERTER PUMP Up to 1 kw (on demand) From 180 to 80 kw (on demand) H [m] MAGNA 3-0 N, Hz eta [%] H [m] MAGNA1 - F N, Hz eta [%] Liquido pompato = Acqua Liquido pompato = Acqua Temperat. liquido = C Temperat. liquido = C Densità = 983. kg/m³ Densità = 983. kg/m³ 13 11 0 % 1 11 9 90 90 % 0 8 80 9 90 7 80 % 8 80 6 7 5 % 6 5 4 % 4 3 % 30 3 30 % 0 0 1 31 % 1 P1 [W] 0 0 1 3 4 5 6 7 8 9 11 Q [m³/h] 0 P1 [W] 0 0 4 6 8 1 14 16 18 0 4 Q [m³/h] 0 180 4 1 0 1 3 300 0 80 00 1 0 0 0 0 PRESSURE DROPS AGUAdens T Pressure drops (kpa) A = AGUAdens T B = AGUAdens 0 T and AGUAdens 115 T C = AGUAdens 1 T D = AGUAdens 180 T and AGUAdens T E = AGUAdens 80 T Water flow (m 3 /h) 17

AGUAdens T TECHNICAL DATA TECHNICAL FEATURES AGUADENS UM T 0T 115T Type (Flue exhaust/air intake type) B3; Category IIH3P IIH3P IIH3P CE-type Certificate (PIN) 0476CR17 0476CR17 0476CR17 Minimum/Maximum heat input kw 14,7/69,9 1,0/99,0 1,0/115,6 Maximum output (80/) P kw 67,9 95,6 111,7 Efficiency at 0% load (80/) % 97 97 97 Minimum output (80/) kw 14,1 11,5 11,5 Efficiency at minimum output (80/) % 96 96 96 Minimum/Maximum output (/30) kw 15,6/74,0 1,8/4,7 1,8/1,3 Efficiency at minimum/maximum output (/30) % 6/6 7/6 6/6 Chimney loss burner on (80/) % 1 1 1 Chimney loss burner on at minimum output heat % 0,5 0,5 0,5 Chimney loss burner off % 0,1 0,1 0,1 Casing loss burner on/off % 0,05/0,1 0,05/0,1 0,05/0,1 Loss at no load % 0,05 0,05 0,05 Gas supply pressure G0/G5 mbar 0/5 0/5 0/5 G30/G31 mbar 30/37 30/37 30/37 Gas supply minimum/maximum pressure G0 mbar /45 /45 /45 Main exchanger water content It 7,57 1,68 1,68 Minimum operating water flow rate with motorised valve l/h 160 160 160 Minimum operating water flow rate without motorised valve l/h 160 3 3 D.H.W. adjustment range C 0-80 0-80 0-80 Maximum temperature for safety intervention C 95 95 95 PMS maximum pressure bar 11 11 11 Minimum pressure bar 1 1 1 Rated power supply voltage/frequency V/Hz 30/ 30/ 30/ Absorbed electrical power W 1 0 0 Degree of electrical protection IP0 IP0 IP0 Burner electrical power W 1 0 0 Air intake and flue exhaust duct diameter (split) mm 80 1 1 Max. air intake and flue exhaust duct length (split) m Equivalent length of one curve m 4 4 4 Weighted CO (0% O) G0 ppm 15 15 15 Weighted NOx (0% O) (EN 483 class 5) G0 ppm 15 15 15 G0 % 8,5 / 8,7 8,5 / 8,7 8,5 / 8,7 CO (%) at minimum / maximum output heat G5 % 8,3 / 8,8 8,3 / 8,8 8,3 / 8,8 G30 %,1 /,6,1 /,6,1 /,6 G31 % 9,8 /, 9,8 /, 9,8 /, G0 % 5,8 / 4,9 5,8 / 4,9 5,8 / 4,9 O (%) at minimum / maximum output heat G5 % 5,8 / 4,9 5,8 / 4,9 5,8 / 4,9 G30 % 5,9 / 5,1 5,9 / 5,1 5,9 / 5,1 G31 % 6,0 / 5,4 6,0 / 5,4 6,0 / 5,4 Maximum flue gas recirculation in case of wind % Minimum/Maximum flue gas temperature at appliance outlet C 30/90 30/90 30/90 Δt temperature fumes/return (at 0% of the load) (80/) C 16 16 17 Δt temperature fumes/return (at 30% of the load) (37/30) C 1 1 1 Flue gas mass flow rate kg/h 115 163 190 Flue gas mass flow rate at minimum output heat kg/h 5,4 0,7 0,7 Head available at exhaust Pa 1 1 1 Maximum combustion air temperature C Maximum CO content in combustion air % 0,9 0,9 0,9 Maximum over-heating flue gas temperature C 9 9 9 Max. admissible vacuum in the flue exhaust/intake system Pa Maximum condensate flow rate l/h 8,7 1,0 14,4 Condensate average degree of acidity PH 4 4 4 Operating ambient temperature C 0 ; + 0 ; + 0 ; + Boiler weight (empty) kg 98 14 14 18

AGUAdens T TM AGUAdens T TENDERING SPECIFICATIONS 1T 180T T 80T C43 ; C53 ; C63; C83 IIH3P IIH3P IIH3P IIH3P 0476CR17 0476CR17 0476CR17 0476CR17 14,7/1,0 14,7/173,4 14,7/,0 14,7/80,0 135,8 168, 03,7 71,6 97 97 97 97 14,1 14,1 14,1 14,1 96 96 96 96 15,6/148,0 15,6/183,3 15,6/,0 15,6/96,0 6/6 6/6 6/6 6/6 1 1 1 1 0,5 0,5 0,5 0,5 0,1 0,1 0,1 0,1 0,05/0,1 0,05/0,1 0,05/0,1 0,05/0,1 0,05 0,05 0,05 0,05 0/5 0/5 0/5 0/5 30/37 30/37 30/37 30/37 /45 /45 /45 /45 15,14,,71 30,8 160 160 160 160 3 48 48 6480 0-80 0-80 0-80 0-80 95 95 95 95 11 11 11 11 1 1 1 1 30/ 30/ 30/ 30/ 300 430 430 590 IP0 IP0 IP0 IP0 300 430 430 591 1 1 1 1 4 4 4 4 15 15 15 15 15 15 15 15 8,5 / 8,7 8,5 / 8,7 8,5 / 8,7 8,5 / 8,7 8,3 / 8,8 8,3 / 8,8 8,3 / 8,8 8,3 / 8,8,1 /,6,1 /,6,1 /,6,1 /,6 9,8 /, 9,8 /, 9,8 /, 9,8 /, 5,8 / 4,9 5,8 / 4,9 5,8 / 4,9 5,8 / 4,9 5,8 / 4,9 5,8 / 4,9 5,8 / 4,9 5,8 / 4,9 5,9 / 5,1 5,9 / 5,1 5,9 / 5,1 5,9 / 5,1 6,0 / 5,4 6,0 / 5,4 6,0 / 5,4 6,0 / 5,4 30/90 30/90 30/90 30/90 17 17 17 17 1 1 1 1 30 84 345 4 5,4 5,4 5,4 5,4 1 1 1 1 0,9 0,9 0,9 0,9 9 9 9 9 17,4 1,5 6,1 34,8 4 4 4 4 0 ; + 0 ; + 0 ; + 0 ; + 147 11 11 49 Modular, D.H.W. only production, commercial gas condensing water heater for indoor installation - Type COSMOGAS AGUAdens T - Vertical water heater height mm floor dimensions 0 x 0 mm - Maximum heat output (80/) kw - Maximum heat output (/30) kw - Minimum heat output (80/) kw - Minimum heat output (/30) kw - Maximum heat input Q kw - Minimum heat input kw - Efficiency at 0% load (80/) % - Efficiency at maximum heat output (/30) % - Efficiency at minimum heat output (80/) % - Efficiency at minimum heat output (/30) % - Efficiency at 30% partial load % - Turndown ratio 1: - R.V.C. (Radial Variable Circulation) water tubes heat exchangers made of AISI 316 Ti (Titanium) stainless steel, without weld joints - Maximum working pressure 11 bar - Managing, rotation and cascade sequence control of each heat exchanger (thermal unit) - Forced draught and sealed chamber or open chamber - Patented air/gas ratio and combustion control - Ecologic total modulation premix burner made of metal fibre - Class 5 (low polluting emissions: Nitrogen Oxides (NOx) = 15 p.p.m. - Carbon Monoxide (CO) = 15 p.p.m.) - Electronic ignition and ionization flame control - Electronic modulating fan, total modulation of the flame and P.I.D. temperature control - Modulating pneumatic gas valve - High limit supply temperature switch - Supply temperature range 0-80 C - Anti-smell siphon for condensate drain complete with flexible hose - Water heater water pressure switch - Blocked flue pressure switch - Water flow meter - Drain cock - Power supply = 30 V, Hz - Bipolar main power switch - Electric protection rating = IP 0 - Connection to outdoor sensor to control self-adaptive supply temperature - Hot water storage tank temperature sensor - Antifreeze device - Visualization of supply, outdoor, water heater, sanitary circuit if connected to a hot water tank, auto-diagnostic of all components and function, PC serial connection for diagnostic - Backlit digital display - Remote control set up - Black painted plate casing complete with window to access the condensate acidity neutralizer (standard) On demand: - -way motorized valves to adjust the water flow on each thermal element 19

SIZE AND CONNECTIONS AGUAdens T AGUAdens T - 0 T - 115 T - 1 T FRONT VIEW 1 3 D.H.W. supply 1 1/ Cold water inlet 1 1/ Air intake Ø80 mm ( T) Ø1 mm (0 T - 115 T - 1 T) SIDE VIEW 4 5 6 - REAR VIEW Flue gas outlet Ø80 mm ( T) Ø1 mm (0 T - 115 T - 1 T) Gas inlet 1 Condensate drain Ø8 mm AGUAdens 180 T - T - 80 T FRONT VIEW 1 - D.H.W. supply DN 65, PN 16 - Cold water inlet DN 65, PN 16 SIDE VIEW 3 - Air intake Ø1 mm 4 - Flue gas outlet Ø1 mm 5 - Gas inlet 1 1/4 6 - Condensate drain Ø8 mm 0 REAR VIEW

AGUAdens T TM ERP PRODUCT FICHE (a) Supplier s name or trade mark COSMOGAS AGUADENS (b) Supplier s model identifier T 0T 115T 1T 180T T 80T (c) Load profile XXL (1) 3XL () 3XL () 3XL () 3XL () 4XL (3) 4XL (3) (d) Water heating energy efficiency class A - - - - - - (e) Water heating energy efficiency ηwh % 85,6 84,1 83,6 83,1 83,8 83,5 83, (f) Daily electricity consumption Qelec kwh 0,19 0,35 0,37 0,36 0,39 0,51 0,54 (f) Annual electricity consumption AEC kwh 4 77 81 79 85 11 118 (f) Daily fuel consumption Qfuel kwh 8,17 54,734 55,01 55,356 54,81 1,778 111,111 (f) Annual fuel consumption AFC GJ 43 43 44 43 88 88 (g) Other load profiles - - - - - - - (g) Water heating energy efficiency * % - - - - - - - (g) Daily electricity consumption * kwh - - - - - - - (g) Annual electricity consumption * kwh - - - - - - - (g) Daily fuel consumption * kwh - - - - - - - (g) Annual fuel consumption * GJ - - - - - - - (h) Thermostat temperature settings of the water heater C (i) Sound power level indoors LWA db (j) The water heater is able to work only during off-peak hours NO NO NO NO NO NO NO (k) Any specific precautions that shall be taken when the water heater is assembled, installed or maintained. Read the installation, use and maintenance manual of the water heater. (l) Smart control N/A N/A N/A N/A N/A N/A N/A Emissions of nitrogen oxides NOx mg/kwh 0 0 0 0 0 0 0 According commission delegated regulation (EU) No 81/013 and No 814/013; (1) with tank AGUATANK 1; () with tank AGUATANK 300; (3) with tank AGUATANK 7; * Refers to other load profiles (g); N/A = Not applicable; ACQUACALDA.TECH - THE CALCULATING SYSTEM FOR REAL D.H.W. NEEDS Cosmogas has set acquacalda.tech a program to calculate the real hot water needs both for the domestic that for the tertiary sector. A useful work tool for technicians and a valuable support to designers, to define domestic hot water specific needs to each user such as hotels, camping sites, apartment buildings, gymnasiums, football fields. To speed up and optimize the drafting of estimates and tendering specifications of Cosmogas products, it provides: Technical report Tendering specifications Installation schemes in dwg format Installation schemes in pdf format Based upon the legislation: UNI 918 - hot and cold water supply and distribution installations - design, installation and testing - the software binds the legislation to the experience of Cosmogas that has been handling with D.H.W. for years. The application acquacalda.tech is not a simple product configurator, but a real work tool that determines the real hot water needs in most demanding users. In fact the software, after calculating the needs for different users, selects the most suitable Cosmogas Solution. 1

TECHNICAL DATA SIZE AND CONNECTIONS AGUAtank AGUATANK TECHNOCAL DATA UM 1 00 300 0 7 00 Capacity l 1 00 300 0 7 00 Heating fluid/heated fluid Water Water Water Water Water Water Lower auxiliary heat exchanger On demand Auxiliary coil material Tinned copper Auxiliary coil thickness mm 1 1 1 1 1 1 Auxiliary exchanger surface m 1,53 1,53 1,53 1,53 1,53 1,53 Vessel and connections material Fe 3 Steel Vessel thickness mm 3 3 3 3 4 4 Glass lining temperature C 800 800 800 800 800 800 External cover material/color PVC/White Cap material/color ABS/Black Insulation material PUR PUR PUR PUR VLIES VLIES Insulation thickness mm 0 0 Kboll (UNI TS 11300-) W/K 1,34 1,51 1,68,5,80 3, Standing loss W 56 61 94 116 145 D.H.W. operating maximum pressure bar 6 6 6 6 6 6 Hydraulic test bar 1 1 1 1 1 1 Operating maximum temperature C 95 95 95 95 95 95 Anodic protection Magnesium Magnesium Magnesium Magnesium Electronic Electronic Anodic protection connection diameter 1 1/ 1 1/ 1 1/ 1 1/ 1/ 1/ Anodic protection diameter and length mm 35x0 3x0 3x4 3x6 3x375 3x375 Empty/Full weight kg 51/01 59/59 75/375 4/4 168/918 180/1180 AGUAtank DIMENSIONS COMPLETE WITH INSULATION AND CONNECTIONS 1 3 1 3 1 1 1 1 A B E 4 5 90 UPPER VIEW E F 1 - Inlet/supply connections (1 1/ per 1 litres) - Temperature sensor connection 1/ 3 - Thermometer (1 litres excluded) 4 - Drain connection 1 1/4 (7 and 00 litres only) 5 - Anodic protection (magnesium up to 0 litres, electronic for 7 and 00 litres) AGUAtank 1 No. 6 connections Ø1 1/ AGUAtank 00/300 No. 6 connections Ø AGUAtank 0/7/00 No. 8 connections Ø 1 1 1 1 B C D A 1 1 1 4 B 1 C D up to 300 litres up to 0 litres Dimensions Mod. 1 00 300 0 7 00 A 1.185 1.335 1.5 1.800.0.0 B 0 0 6 7 9 990 C D 300 300 300 300 300 300 E F 45 45 45 45 45 0 45 0 AGUAtank TENDERING SPECIFICATIONS Vertical, floor standing, hot water storage tank, for technical and domestic hot water made of Fe 3 steel and internal glass lined treatment - Type COSMOGAS AGUAtank - Capacity litres - Insulation: mm PUR expanded polyurethane (1 to 0 litre models) or 0 mm VLIES (7 and 00 litre models) - External cover: white sky - Connection No.: 6 connections 1 1/ (1 litre model), 6 connections (00 and 300 litre model), 8 connections (0, 7 and 00 litre models) to guarantee a constant and silent supply even at great flows. Pre-equipped for finned copper coil exchanger connection (on demand) - Inspection flange - Magnesium anodic protection - Electric resistance connection (on demand) - No. 4 temperature sensor connections - Thermometer connection - Energy Label: B (1 to 300 litres models), C (0 to 00 litres models)

AGUAdens T TM OPERATING CONDITIONS: AGUAtank storage temperature C and dimensioned storage 1 litre per kw. AGUAdens T + AGUAtank D.H.W. PERFORMANCE 3 MODEL Cold water inlet temperature C Hot water supply temperature C Produced water in l/min (storage temperature at C) min 0 min 30 min min min min AGUAdens 115 T + AGUAtank 1 litres AGUAdens 1 T + AGUAtank 1 litres AGUAdens 0 T + AGUAtank 1 litres 5 C 588 775 737 739 986 1399 19 184 1886 59 09 3045 946 303 4197,5 56,8 55, 57,3 80,3 666 649 8 84 161 1596 186 180 558 543 351 3518 47,3 47,3 66,3 66,9 993 134 189 131 1789 1804 478 394 459 3394 615 3613 3499 36 00 6,9 5,8 5,4 4,9 4,1 1139 11 153 1511 085 069 849 849 3031 3016 4174 4186 6,3 5,9 5,0 4,5 499 5 615 63 9 141 1561 1635 1918 1978 8 638 35,5 36,8 47,3, 854 873 88 1133 1564 19 035 137 73 346 98 31 6,3 5,9 5,0 4,5 457 553 553 575 5 88 1364 1381 1467 1851 1718 175 358 998 31,5,5 41,4 44,6 57,3 399 413 478 5 967 15 114 1308 1535 1618 1951 111 8,4 30,1 36,8,1 77 959 967 1 178 13 17 1796 191 45 034 581 64 804 3571 6,9 5,8 5,4 4,9 4,1 683 714 846 907 151 1317 1583 19 1818 1919 319 51 6,3 5,9 5,0 4,5 374 430 44 4 548 890 61 15 0 14 16 169 1768 1930 33 5,8 31,5 33,1 36,5 44,6 333 349 391 41 806 859 994 90 179 1369 1596 1759 3,7 5,5 30,1 33,4 63 746 774 835 994 1148 1376 1436 1565 1886 1664 007 099 94 778 6,9 5,8 5,4 4,9 4,1 569 4 69 755 4 1114 195 144 1515 164 1897 093 6,3 5,9 5,0 4,5 316 35 369 398 448 753 868 91 15 1178 1190 1384 1473 1633 1908 1,8 5,8 7,6 30,9 36,5 535 6 645 7 813 971 116 1197 134 1543 18 164 1749 1941 73 6,9 5,8 5,4 4,9 4,1 5 C 5 C C C C 15 C 15 C 15 C Continuous water flow l/min AGUAtank recovery time min AGUAdens T + AGUAtank 00 litres AGUAdens 80 T + AGUAtank 300 litres AGUAdens 180 T + AGUAtank 00 litres 5 C 961 181 13 1478 1973 435 3345 330 3771 5183 3909 59 536 64 8394 73,7 3, 0,3 114,7 1,5 94 71 1436 1684 814 791 3844 43 4534 4511 65 35 86,0 86,0,4 133,8 1698 313 6 64 3578 317 4377 433 4918 6789 4646 6441 6 711 9999 5,0 4,3 4,0 4,9 4,1 1954 1931 6 30 3674 3651 48 5697 5394 5371 7456 8373 4,7 4,3 3,7 4,5 81 833 5 163 111 171 745 3 31 39 4465 576 64,5 66,9 86,0 0,3 1466 1 1885 66 756 8 35 473 46 4178 535 680 4,7 4,3 3,7 4,5 747 915 917 1149 19 1894 389 4 933 3 30 3863 397 4717 5996 57,3 73,7 75,3 89, 114,7 656 68 798 1688 1776 135 616 70 871 3473 41 51,6 54,7 66,9 80,3 130 165 16 041 556 467 316 3175 385 4849 3614 41 4680 59 714 5,0 4,3 4,0 4,9 4,1 117 19 1466 1813 04 33 804 3418 336 3418 414 4 4,7 4,3 3,7 4,5 611 71 734 9 96 1549 1858 1938 0 880 488 3005 314 3859 4663 46,9 57,3, 73,0 89, 547 577 653 84 17 13 1747 180 67 49 84 3518 43,0 46,3 54,7 66,9 80 185 1336 16 1988 019 43 5 319 377 957 3578 3744 4589 5555 5,0 4,3 4,0 4,9 4,1 977 0 1511 1837 1966 94 849 697 89 3389 4186 4,7 4,3 3,7 4,5 517 58 61 796 897 1311 150 1615 031 356 5 459 618 365 3816 39,7 46,9, 61,7 73,0 914 51 1113 1413 166 18 1989 117 648 3086 98 3 3883 4545 5,0 4,3 4,0 4,9 4,1 5 C 5 C C C C 15 C 15 C 15 C

61330 - Maggio 017 - WITH THE AIM OF CONSTANTLY DEVELOPING AND IMPROVING IT S PRODUCTS, COSMOGAS RESERVES THE RIGHT TO MODIFY, UPDATE AND IMPROVE, AT ANY TIME, THIS FOLDER. Massimiliano Pieraccini COSMOGAS International Certifications COSMOGAS srl Via L. da Vinci, 16 414 MELDOLA (FC) ITALY Tel. +39 0543.49.83. Fax +39 0543.49.83.9 www.cosmogas.com info@cosmogas.com EU Ukraine Boilers designed, patented and manufactured by us Eurasian Union USA USA Canada Contact us Copyright COSMOGAS - ALL RIGHTS RESERVED AUTHORIZED DEALER PURCHASE ORDERS - export@cosmogas.com SPARE PARTS - export@cosmogas.com