If you are a beginner please feel free to contact us at any time regarding our electroplating course for beginners.

Similar documents
Buehler Cast N Vac 1000 Embedding System

AUXIE - 1S ELECTROPOLISHING UNIT, MODEL E796 HOW IT WORKS SAFETY PRECAUTIONS

Getting the most out of your cookware

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

Marley Ultra Quiet Fan

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

Instructions for the Use and Care and Installation of ORW6XA ORW9XA. Wall Canopy Rangehoods

ANTIBACTERIAL HAND VAC WITH UV LIGHT

489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power

Instructions for the Use and Care and Installation of ORC97G ORC98G. Glass Canopy Rangehoods

HHP-300 EXTRACTOR 120V

SERVICING INFORMATION

VT-DESOL2 DESOLDERING STATION DESOLDEERSTATION STATION DE DESSOUDAGE ENTLÖTSTATION USER MANUAL GEBRUIKERSHANDLEIDING MANUEL D'UTILISATION

Filabot EX6 Extruder. Operation Manual. CAUTION! Read Carefully. Filabot Vermont, USA, Earth

Operation Manual R205BV, R209BV

MERCHANT POPCORN MACHINE SERVICE MANUAL

Owners Manual MINI-CLASSIC II. Pure Water. Water Distiller

Application Instructions

Dissolved Oxygen Sensors

HOW TO USE YOUR 2000 RANGE L.P.G. COOKER OR HOB UNIT

CHAPTER 1 SAFETY SUMMARY CHAPTER 2 MACHINE FAMILIARIZATION CHAPTER 3 UNPACKING AND INSTALLATION CHAPTER 4 OPERATION INSTRUCTION

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

Product Description and Measurements. Thank You. Prior To Installation Steps. Waterfall Faucet Installation

ENRGY CURB APPLICATION GUIDE FOR TPO ROOFING SYSTEMS

Leica EM ACE600 Carbon & Iridium Coating System

Carbon Heating Film. Failure to follow these instructions may result in fire, electrical shock, property damage, personal injury, or death.

SHOT BLAST CABINET USER INSTRUCTIONS. Model No: CSB20B. Part No: GC05/13

ANTIBACTERIAL HAND VAC

WINDSHIELD REPAIR MANUAL SUPER CINCH

The plating industry

1. Plug electric cord to appropriate 110V 220V electrical outlet. Push the off/on switch to fill position.

User Guide. For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final. Copyright 2014 Page of 20

Quick Start Guide LIQ-QSG-Hx438, Rev A June Rosemount Hx438. Amperometric Steam Sterilizable Dissolved Oxygen Sensors

Our Range of Quality Electrical Products

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

Congratulations with your purchase of our high quality, corrosion-free hot water cylinder (HWC).

Chicken Door User Manual

USER AND INSTALLATION INSTRUCTIONS

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies

R7521SS COLORS/FINISHES. Stainless Steel 21 15/16" 1 3/16" 8 5/64" 1 25/32" 2 1/8" 23 5/8" Max. 1 3/8" G1/2" Female

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

St. Anthony's Canossian Secondary School Sec 3NA Science (Physics) Chapter 7 Transfer of Thermal Energy. Name: ( ) Class: Sec Date:

HOW TO USE YOUR 2500 RANGE L.P.G. COOKER OR HOB UNIT

R7520SS COLORS/FINISHES. Stainless Steel 16 9/16" 7 15/16"

EASYkleen TEC BRUSH. DC Weld Electropolisher

Guide for Thin Film Evaporation Edited 7/22/13 by Stephen Albright, BJAM & Steven Palefsky

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

ASTRO PORTABLE LPG CABINET HEATER Model No. KCH

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

SAFETY AND OPERATING MANUAL

Belling. Gas Hob GHU573 - GHU573T GHU70GE - GHU70TGE - GHU70GC GHU70TGC - GHU60GC INSTALLATION AND USER INSTRUCTIONS

INTRODUCTION / TABLE OF CONTENTS

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

METRO BASIN MONO MIXER CHR

ROHL Modern Bath Lombardia/Architectural ROHL Transitional Bath Avanti COLORS/FINISHES. Polished Chrome Polished Nickel Satin Nickel

RND Soldering Station. RND W Temperature Controlled Soldering Station Instruction Manual

INSTRUCTION MANUAL W-400

INSTRUCTION MANUAL Wall mounted Cooker hood Nebel INOX 90

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

*****Important Read First*****

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

1SC-SSC Splice Connection Kit Installation Instructions

Beautifully Traditional

MODEL SW-2. Sample specifications for SW-2 SPECIFICATIONS

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine:

MODEL PR16 POWER ROTARY

Fume Free Casting Box

CHAPTER 1 SAFETY SUMMARY CHAPTER 2 MACHINE FAMILIARIZATION CHAPTER 3 UNPACKING AND INSTALLATION CHAPTER 4 OPERATION INSTRUCTION

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

MW402 Integrated Dishwasher

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Syrup Server. Thank You MODEL: SY MODEL: SY for purchasing this Syrup Server to heat and neatly dispense sticky syrups and sauces.

UF424 and UN324. Technical Service

Owners Manual. Model MINI-CLASSIC CT. Pure Water. Water Distiller

Industrial Science Seminar

21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING.

Purify your chromic acid solution at the same time that you chrome plate parts.

Beautifully Traditional

3gb53231b.fm5 Page 12 Friday, April 11, :21 PM

M07. Wunda Premium Manifold. Before you start: Check the contents THE BRAND YOU CAN TRUST

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Beautifully Traditional

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Precision in Roller Technology

Rycroft Storage & Non-Storage Calorifiers. Installation, Operation & Maintenance Manual

Nilfisk Inc Winnetka Avenue North Minneapolis, MN REV.03( ) VF80189

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Manual Centrifuges - Installation and Operation

TG-10 Wall Mount Installation and Operation Manual. High Output Ozone Generator

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø)

ESD Safe UL Approved INSTRUCTIONAL MANUAL EX V EX V TEMPERATURE CONTROLLED SOLDERING STATION

TRIO Rx. Portable Ultra- High FAC Decanter Activator Set Instruction Manual

MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL

OPERATING & SERVICE PARTS MANUAL 700ES ENERGY SMART WRAPPER SERIES C

HOW TO USE YOUR 4500 RANGE L.P.G. COOKER OR HOB UNIT

3/4 HP Model Trimmer Operating Instructions

Transcription:

COMPACT BARREL ELECTROPLATING MACHINE (MANUAL & AUTOMATIC) USER MANUAL DO NOT USE BEFORE READING THESE INSTRUCTIONS PRODUCT INTRODUCTION: This compact barrel electroplating machine is designed for cleaning, stripping, activating or coating parts by conducting an electrical current through electrochemical means. There are two types of this machine available, a manual rotating machine or a motorised (automatic) machine (6-7 RPM). This machine can also be used for barrel, tank or brash plating. ELECTROPLATING: An electroplating process involves covering a certain metal so that an adherent and a durable film of any other metal can then be applied. The process is performed in a tank containing a solution, which undergoes an electrolytic action induced by a current from a source of an electric power. The barrel electroplating machine is connected to a source of electric power and converts its energy into a direct current of up to 15 volts. Upon the immersion of the cathode and the anode into the solution, an electric current moves through the solution and thus completing the electric circuit which triggers the motion of metal ions from the solution. This results in a coating of the cathode by the atoms of the metal. At the same time an equal amount of the same metal is discharged from the anode into the solution. This process is widely used in jewellery and the electronics industry, decorating, crafts, arts, etc (Gold, Silver, Copper, Nickel, Chrome, Rhodium plating / forming etc.) IMAGES OF THE MACHINE: If you are a beginner please feel free to contact us at any time regarding our electroplating course for beginners.

Technical specification: INPUT 220V - 240VAC / 110V 120VAC OUTPUT (V) 0-15 VDC OUTPUT (A) 0 4 ADC BARREL x 1 BARREL S DIMENSIONS (MM) 120(D) X 65 ESTIMATED BARREL CAPACITY 20 (RINGS) /0.5 L/1 KG TURNING VERSION AVAILABLE MANUAL & AUTOMATIC GAUGE A FILTER x 1 (1000 McF+) TANK x 1 (200 x 90 x 90 mm) TANK VOLUME 1 L STRAPPING OPTION YES SS ANODE (cleaning, gold, silver process) YES (400 X 70 mm) x 1 WEIGHT 2.8 Kg UNIT DIMENSIONS (MM) 350(W) X 230(D) X 130(H) DELIVERY SPECIFICATIONS: Please make sure the delivery includes the following components: Barrelling machine x 1; Barrel with an aluminium mesh x 1; Plastic tank x 1; Stainless steel anode for cleaning & Gold and Silver plating processes; Instruction manual (downloadable). PREPARATION: To prepare your articles for electroplating it is important to ensure that all oil, grease, paint or other materials are removed prior to processing. The most common cause of poor quality forming/plating is insufficient preparation. It is recommended to use ultrasonic or electromagnetic cleaners, sand cabinets or alternatively vigorous brushing with soapy water may polish the compound well. In any case, use an electro cleaning process before starting any type of plating process. Also make sure that you do not touch the object with your hands after cleaning.

INSTALLATION AND OPERATION: NOTE: the thickness and quality of a coating is a complex function of electric current, voltage, temperature of the solution, time of exposure, correct position of the cathode in the tank, correct distance between the anode and the object, quality of chemicals and user s experience. The installation and operation of this unit does not require professional knowledge or specific training and it can be easily used by beginners. After making sure that you have all the necessary materials, place the unit in a suitable level position. Please do not move this machine by rotating the wheel and never touch the body when the power is on. Once the machine is properly placed on a worktop please make sure that it is installed correctly (please use the pictures as a guide): 1. Unscrew the plastic lock-nut from the open side of the barrel and take out the plastic disc with a level mark from its plastic rod. Now your barrel is in an open position and you can load it (on 1/3) with any suitable objects you wish to clean, strip, activate or plate. Please do not overload the barrel as it can damage your machine or increase plating time and do not open the other side of the barrel as it has contact with a negative source.

2. When all required objects are in the barrel put the plastic disc (lid) back on its place and fix it on the central plastic rod by the plastic nut. Now screw the lock-nut back and tighten it slightly. Please repeat the same operation each time you need to load or unload the barrel if you use the same barrel for all processes. 3. Place the anode inside the plastic tank. Make sure that the anode is placed in the tank in the correct way. 4. Place this plastic tank with the anode under the barrel so that the barrel rotates inside the tank freely, not touching each other. The plastic tank has a small gap on one wall that must be placed in the correct position between the barrel and the machine. 5. Now the anode can be connected to the positive power source by RED clamp that can be found on the back panel of the machine. 6. Also connect the barrel to a negative power source by BLACK clamp as shown on the picture below. Now your machine is ready to work.

REMEMBER: The ampere gauge shows amperes range only when the anode and barrel are in the solution and under an electric current (switched on) INSTRUCTIONS: Prepare the solution you wish to use and fill the tank up to a level mark which should be just about 10-15 mm UNDER the lock-nut. Make sure that the voltage regulator (the knob on the front panel with 0-9 digits) is in the far left position. Check that red and black clamps are connected correctly. Switch the power ON by using the potentiometer with a pointed knob. The Power indicator will be switched on. When you turn the voltage regulator to the correct position the right indicator 0-15Vdc will switch on. Note: it will be brighter on a higher voltage. When you connect all the wires and get the correct voltage (usually position 5-7 (around 1.5V per one digit on the knob) rotate the barrel by using either the handle or the motor. Note: plating time and layer quality depends on rotating speed and your experience. It is usually 5-10 RPM. When the objects have been plated you will see this inside the barrel, switch the machine OFF and take out the barrel from the tank. Then, open the plastic lid of the barrel and take the finished objects out. Then, place them into a glass or plastic container and then clean them together with the barrel in water. Now the barrel is ready to be loaded again with other objects. Pen-stick or a brush-probe may also be connected to this machine. To do that just connect the red clamp to a pen or brush and then connect the black clamp to the object that needs to be plated. You can also use this machine for a standard tank plating process. For this purpose just use any suitable plastic or glass container. Fill this container with the required solution.

Then place an anode in the solution and connect it to a positive (red) clamp. Now connect the object to be plated to a metal rod (aluminium, copper, steel) via a copper or aluminium wire and place the rod on the top of this container. Please make sure that the object is fully immersed in the solution. NOTE: the ampere gauge starts to show amperage range only from 1+ ampere. Most electrochemical processes require amperage lower than 1A. If you see that the ampere meter s coil on your machine does NOT move during the process it means that this process requires less than 1A. You can see whether your machine is under voltage using the right indicator. You can also check whether the process is in progress by checking the solution inside the barrel. You will be able to see some small bubbles around the objects being plated and the solution will be white in colour. If you still wish to increase the amperage please do the following: Add 1-2 drops of sulphuric acid to the solution (first check the solution data sheet); Increase voltage; Increase the number of the objects being plated and the area of the anode but always remember that the lower the amperage the better the result. So always try to hold the ampere gauge s coil at 0 position if the data sheet does not advise otherwise. HEALTH AND SAFETY: Always make sure that the machine is kept clean and stored in a dry place. Never keep chemicals and solutions in the tanks. All electrochemical processes are subject to two main hazardous effects: electrical injury and poisoning by solutions and their gases. To avoid electrical injury the user must not touch bare leads of the Unit with unprotected hands. Always use rubber gloves. This will also be useful to protect hands from the effect of the solutions. It will also be necessary to provide the operating area with a rubber mat to stand on. Some chemicals may be deadly poisonous and in combination often produce corrosive and poisonous gases. Therefore, all general safety measures should be undertaken when working with them including eye protection, skin protection, inhaling protection etc. Always keep children away from the work area. Ensure proper ventilation of the work area. The user should carefully follow all instructions provided by the chemicals supplier. info@technicalsupermarket.com +44 (0) 208 555 9607 www.technicalsupermarket.com