Refrigerant Dryers DRY with PDP Indicator

Similar documents
CDX Refrigerant dryers

Refrigeration dryers DW 2-504

Refrigeration dryers DW 2-504

REFRIGERATION DRYERS OP 05 - OP 190

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

CHAPTER 1 INTRODUCTION

Refrigerant air dryers. FD series ( l/s, cfm)

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Refrigerated Air Dryers. Catalogue

Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Brazed Plate Heat Exchanger for CO Applications

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

A study on retrofit methodologies for legacy air-conditioning systems to reduce their impact on global warming and ozone depletion

March 10, 2016 San Joaquin Valley RETA Meeting

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A 11 - A 12 - A 13 - A 14 (R410A)

REFRIGERATED AIR DRYERS

Ammonia. Background on ammonia as a refrigerant

DEEPAK PALIWAL, S.P.S.RAJPUT

Development of centrifugal chiller and heat pump using low GWP refrigerant

Transcritical CO2 Bottle Cooler Development

Design of LPG Refrigeration System

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

Design and Operation of a Conditioning Energy Recovery Ventilator (CERV) for Passive Houses

GTX Series Thermal Xchange Cycling Refrigeration Dryers GREAT LAKES AIR ANDARD ELECTRONIC DRAIN 5 -YEAR WARRANTY F PRESSURE DEWPOINT

Refrigeration Air Dryers ADQ. Capacity: m 3 /h

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

Evaluation of HCFC Alternative Refrigerants

REFRIGERATED AIR DRYERS

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp)

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Study of R161 Refrigerant for Residential Airconditioning

Chapter 10. Refrigeration and Heat Pump Systems

F-H Refrigerated Dryers

Refrigeration Dryers TH-TI Series

Energy-Saving Refrigeration Dryers SECOTEC

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

A Comparison Between Refrigerants Used In Air Conditioning

REFRIGERATION AIR DRYERSDW DW 2-420

Energy Saving Refrigerated Air Dryers SRC Cycling Dryers

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Campbell Soup Company Extends Use of CO2 Systems Into Their Operations

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

DRYPOInt RA. Drying. The concept determines the efficiency. DRYPOINT RA, the most economic way to dry compressed air

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Refrigerated Air Dryers VF Series. DHT Series. Non-Cycling 10-2,000 scfm scfm

QUINCY QPNC SERIES NON-CYCLING QUINCY QRHT SERIES HIGH TEMP

High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A. Hitachi Appliances, Inc.

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Atlas Copco. Refrigerant Air Dryers FX Hz

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series

Above & Beyond. Refrigerated Compressed Air Dryers

Experimental Investigation on R 290 and R 600a In a Vapor Compression Refrigeration

Gary Parker Refrigerants Product Manager

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Thermodynamic Cycle Analysis of Mobile Air Conditioning System Using HFO-1234yf as an Alternative Replacement of HFC-134a

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp)

Boreas DV DV AB / WB

R-407A R-448A R-449A

Owners Manual Refrigerated Air Dryer MHT SERIES

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

Commercial Refrigeration

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

Energy-Saving Refrigeration Dryers SECOTEC

compact BOOSTER RACK TRANSCRITICAL CO 2 Cooling capacity LT: from 2 to 130 kw Cooling capacity MT: from 20 to 300 kw

The analysis proceeded by adopting the ASHRAE guideline for conventional HVAC chiller applications. This guideline is summarized in Table II.

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

HFCs or the Old Refrigerants - what is the best Choice?

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Combination Dryer HYBRITEC

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

Energy Use in Refrigeration Systems

Refrigerated Compressed Air Dryers

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Zero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons.

ThermoStar Refrigeration Air Dryers

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

Refrigeration Cycle Demonstration Unit R633

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Development and Handling of Hydrocarbon Air-conditioners The Godrej Experience

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

JJMIE Jordan Journal of Mechanical and Industrial Engineering

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

Transcription:

Refrigerant Dryers DRY with PDP Indicator

Refrigerant dryers range From 333 lt./min up to 21.000 lt./min PDP: 5 C at reference conditions Whole range with the PDP indicator Max. working pressure: 16 bar (A0-A4) Max. working pressure: 13 bar (A5-A14) DRY 20-130 DRY 165-530 DRY 690-1260

Flow chart 1. Refrigerant compressor 2. Refrigerant condenser 3. Fan 4. Refrigerant filter 5. Capillary tube 6. Air/refrig. heat exchanger 7. Liquid separator 8. Hot gas by-pass valve 9. Air/air exchanger 10.Condensate separator 11.Automatic Condensate discharge

Technical Data

Lay-out: DRY 20-130 Instrumental panel Bypass valve Air Air exchanger Air Refrigerant evaporator Condensate separator Automatic condensate discharge Compressor Refrigeration condenser + motor fan Expansion capillary

Lay-out: DRY 165-530 Bypass valve Control panel Air-Air exchanger Refrigeration condenser + motor fan Air-Refrigerant evaporator Condensate separator Refrigerant Compressor

Lay-out: DRY 690-1260 Air-Air exchanger Air-Refrigerant evaporator Condensate separator Bypass valve Control panel Refrigeration condenser + motor fan Refrigerant Compressor Refrigerant filter

Key customer benefits Heat exchanger with a high efficient thermal change. Integrated separator with a low pressure drop DRY 690-1260 range: Rotary compressor designed for R410A is highly efficient and performance = energy saving Intelligent capacitive drain, discharge only water, not compressed air = energy saving; noise free Safety and reliable control panel. Easy access to all the electric components

Heat Exchanger A0-A4 Brazed Plate A5-A14 Aluminium Block Exchanger Air/Air Out - Refrigerant Air/Refrigerant Higher efficiency ( thermal exchange ) Integrated separator Low pressure drop Air Inlet Air Outlet In - Refrigerant Condensate Separator All models include an air-to-air heat exchanger as standard, which prevents condensation forming on the outside of the pipe system.

Condensate Discharge The collected water is discharged by an intelligent system. Discharge only water, NOT compressed air = Energy saving Noise-free, no acoustic impact = Health & Environmental protection Standard device for the whole range

Control Panel A11 - A14 A15 - A20 a) green indicator of voltage running b) red indicator alarm for: high pressure refrigerant gas ( safety pressure switch failed ) fan motor protection ( thermal protection activated ) a) b) a) c) b) c) red indicator alarm for condensate discharger

Standard remote contacts Ref. 1 Remote Start / Stop A11 A20 Ref. 2 One free contact for a Remote General Alarm A11 A20 ( fan alarm; min/max pressure switch ) Ref. 3. One free contact for a Remote Drain Alarm A15 A20

PDP Indicator for DRY 20-1260 Introducing the new Electronic Controller on the dryer range will allow you to see various information about the status of the dryer : alarm, under voltage, fan running, general alarms.

PDP Indicator for DRY 20-1260 The new Controller displays the Pressure Dew Point ( A0-A20) and controls the Condensing Temperature ( A3-A10) through the start/stop of the fan by the use of two NTC type temperature probes ( one for the PDP value and one for the cycles of the fan ). The new device will be not connected to the Schrader Valve anymore, it will consider the condensing temperature instead of the condensing pressure; but basically the principle doesn t change. Reader temperature A0-A2 (there is not the fan pressure switch) Controllers temperature A3-A10 (remove the fan pressure switch) Reader temperature A11-A20 (keep the fan pressure switch)

PDP Indicator for DRY 20-1260 More sales argument, matching the market requirements with improved look & feel PDP Allarm Refrigerant compressor is running ( it will be always light on because our compressors always runs ) Fan is running PDP Alarm means ( not flashing ): High PDP Low PDP = freezing problems

PDP Indicator for DRY 20-1260 Leds & pictograms meaning: For the range A3-A10: A0-A2 & A11-A20: failure alarm P1 High/Low temp. alarm H1 / L1 SE Service A0-A10: after 2000 Hrs. under voltage A11-A20: after 4000 Hrs. under voltage The service timing, can be reset

Free contacts on request DRY 165-1260 Free Contacts ( A5-A20 on request ) with a dedicated part number Three probes connected to the PDP device for a remote: High refrigerant temperature alarm out of refrigerant compressor High/Low temperature alarm high/low PDP Fan probe alarm there is a sensor problem about the Fan probe (A5-A20) (A5-A20) (A5-A10) High refrigerant temp. alarm high temp. (PDP) alarm low temp. (PDP) alarm fan probe alarm x x x non-blocking non-discriminatory ( just a red light ) but on the controller could appear the type of the alarm (A1-A2-P1/2)

Option DRY 20-130 BY- PASS VALVE + FILTER SUPPORT By-pass valve FILTERS NOT included in the kit

Option DRY 20-130 FILTER SUPPORT Copper tubes FILTERS NOT included in the kit

Typical installation with filters 1. Compressor 2. G filter 3. C filter 4. V filter 5. Refrigerant dryer Vertical Receiver is always recommended

Benefits VS Features Reliable Control test cells, experience team in refrigeration, audit, SQA team, internal Quality Control, etc. Easy access and maintenance = lower maintenance cost Easy access to the control panel, Simple lay-out, Intelligent condensate drain discharge as standard for the whole range Discharge only water, NOT compressed air = Energy saving Noise-free = Health & Environmental protection

Refrigerant gas R410A DRY 690-1260

HFCs (hydrofluorocarbons): Refrigerant gas type These hydrofluorocarbons contain no chlorine and therefore have ZERO Ozone Depletion Potential (ODP) and in consequence are not controlled by the Montreal Protocol. Examples are R410A, R134a, R404A. Gas R134a A0-A4 Gas R404A A5-A10 Gas R410A A11-A14

Customer key benefits What s New?... the new Rotary Refrig. Compressor Improved energy efficiency, operating savings Better energy efficiency = reduced energy cost Longer life time, reduced leakages risks, little vibration Rotary compressor designed for R410A is highly efficient thanks a good Coefficient of Performance ( COP ). Integrated liquid separator prevents liquid knock and risk of cracks at liquid separator pipe.

Low GWP (Global Warming Potential): according to EN 378-1 2008-A1:2009 Customer key benefits Refrigerant GWP R134a 1300 R404A 3260 R410A 1720 GWP is the measure of how much a given mass of greenhouse gas is estimated to contribute to global warming. The GWP of the R410A is 50% less than R404A.

Only Quality Air Solution keep your air distribution in optimal shape