Twin radial blower DRG 730

Similar documents
Twin radial blower DRG 1200

Twin radial blower DRG 1200 with oval resistor, 12 and 24 Volt versions

TDS 20 R / TDS 30 R / TDS 50 R

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

TTV 4500 / TTV 4500 HP / TTV 7000

More Precision. indusensor // Linear inductive displacement sensors

INSTRUCTION MANUAL MNBX14

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

MANUAL Oil Level Sensor

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

SINAMICS G130. Cabinet design and EMC. Operating instructions 03/2011 SINAMICS

FACTORY AUTOMATION. Instruction Manual NBB20-L2-E2B-C-V1 NBN40-L2-E2B-C-V1 Inductive Sensor

en Inverter FU 4/5. Operator s Manual

INSTRUCTION MANUAL (English version) Water still

MANUAL Overflow sensor NVF-104/34-PF

UV Flame Supervision System

User manual UV Flash Dry C1

HD Kompakt Service Manual

LC3000 Level Controller Installation and Maintenance Instructions

X99 Series. Dental Handpiece. Instruction For Use

WHIRLPOOL AUSTRALASIA CONSUMER SERVICES

Audible warning devices for external alarm

Installation and assembly instructions. for standard configuration radial blowers

electronics Protection

Thermo-Sealer. Manual Heat Sealer. User Manual

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX. RG CPAP 24 V mit Powermodul 24V sensorless

CIR Carbon Infrared Emitter. Operating instructions

Rules for Intruder Alarm Systems

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

UV - flame detector dual fuel burners for intermittent burner operations

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

Installation and operating instructions KEMPER KHS-Timer-Set Figure and Figure

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Analog Melting Point Apparatus

Test Unit GTL 100 for Fire Detectors

C Note! LGI16... Burner Controls. Building Technologies

SINAMICS G130. Cabinet design and EMC. Operating Instructions 05/2010 SINAMICS

Instruction manual ASPIMAX 16

Instruction Manual Suppository Penetration Tester. Type PM 30

IH 025 VOLCANO. Portable Induction Heater. smart mounting

Procedure for the Approval of New Fire Detection and Alarm Technologies

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

Product Data Sheet 4114 N/17HH-218. The engineer's choice

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory)

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Operating instructions

K 5.80 M ( ) Caution! Do not use the unit without first having read the operating instructions.

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX 2218 F/2TDH4P

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

Whole Room Dryer WRD, WRD/110

Model KBWF 240 Growth chambers with light and humidity

Low-noise fans are not a product of chance

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

AHU INSTALLATION & OPERATION MANUAL

Model KBWF 720 Growth chambers with light and humidity

More Precision. indusensor // Linear inductive displacement sensors

TP /4-A-F-A-BQQE 400D 50HZ

OPERATING INSTRUCTIONS WPSI12. Portable Soldering Station & TCP12. Soldering Tool. Weller Tech Sheet Product Code: Issue A 24/05/05

Vacuum generators VADM/VADMI

Component. Maintenance. Manual Z SERIES. Evaporator Assembly

Installation Instructions Component Systems Professional Line

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

ANNEALING FURNACE MODEL 414 User Maintenance Manual/Handbook

EN , EN , DALI 102/207, SELV Output, KS C 7655 Safety Certification Approved RoHS Compliant. Dim. Method

RE-PR3-E-27 3-Phase Panel Mount 27kW

Operator s Manual. IP-100 Immersion Probe Cooler

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

User instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

User manual. Fjordblink Birth Pool and Water Supply Unit.

Rules for Classification and Construction Additional Rules and Guidelines

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Installation Instructions. Mira LED Light System

HXL. Operating instructions

Operation Manual. Control TJ-HRC

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

Sip Vacuum Cleaner 1400/35 Wet & Dry

Sewage Pumps. KS - Channel Type Pumps W, WTS - Vortex Type Pumps

SCHMIDT LED Measured Value Display MD Instructions for Use

More Precision. indusensor // Linear inductive displacement sensors

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Water Bath SWB1 SWB2 SWB3 SWB1D SWB2D SWB3D. Instructions for use Version 2.0. water bath SWB2D. mains on on. press to set. set. off.

KHM800 Professional 800w haze machine

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

OPERATING MANUAL. ba75825e03 12/2015 LR 925/01 LR 925/01-P LR 925/01(-P) ULTRAPURE WATER CONDUCTIVITY MEASURING CELL

Forced draught gas burner

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

Operator Guide. Publication No. OI /97-Eng. KODAK Automixer II Plus

USER MANUAL TRAINER 201

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

CLIMA CANAL HYBRID CLIMA CANAL. Low Water Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING LOW TEMPERATURE SYSTEM / HEATING

Transcription:

1/7 Twin radial blower DRG 730 Content: 1 Part numbers 2 Safety advises 3 Usage 4 Design 5 Function 6 Technical data 7 Dimensions 8 Installation 9 Characteristic curve 10 Validation A U R O R A Konrad G. Schulz GmbH & Co. KG Tel.: 0 62 84 / 92 02-0 info@aurora-eos.com www.aurora-eos.com The information on this document and the copyrights are ownership of AURORA Konrad G. Schulz GmbH & Co. KG, Joachim Schulz Str. 4, D-69427 Mudau. Transmission or duplication of this document or the utilization of the contents are not allowed without the agreement of AURORA Konrad G. Schulz GmbH & Co. KG otherwise it is explicit allowed. Violation will be prosecuted. All rights of patents, industrial designs and trademarks are reserved. Please pay attention to ISO 16016. - we reserve the right to make technical modifications - established: 06.11.08 KH checked: 27.03.13 CK approved: 27.03.13 CK date/name date/name date/name a) 17385 21.07.11 KH b) 19627 29.01.13 KH c) 19850 27.03.13 KH d

2/7 1. Part numbers 131-301-0000 DRG 730 12V basic version 131-301-0001 DRG 730 12V 1-speed standard 131-301-0002 DRG 730 12V 2-speed standard 131-301-0003 DRG 730 12V 3-speed standard 131-302-0000 DRG 730 24V basic version 131-302-0001 DRG 730 24V 1-speed standard 131-302-0002 DRG 730 24V 2-speed standard 131-302-0003 DRG 730 24V 3-speed standard 131-302-0200 DRG 730 24V 4-speed standard (not available anymore) More versions are available, upon request. This technical Information is valid for all versions of the twin radial blower DRG 730. 2. Safety advises The blower is principle maintenance- and service-free. If there is maintenance work to do, make sure it is to be carried out only when the motor is not running. In order to avoid injuries, the blower is to be separated from the current circuit. Make sure that maintenance work is only carried out by specialised personnel. Do not reach into the blower and never stick objects into it. Please do not get into contact with the resistor on the blower, if it has not completely cooled down. Advice for installation and maintenance work: The rules for the prevention of accidents as well as other recognises technical and labour medical security regulations must be observed. 3. Usage The twin radial blowers DRG 730 can be delivered as a basic version, a 2-speed version, 2-speed-version, or 3-speed version. The twin radial blower DRG 730 is used for powerful usage in heaters, A/C units and ventilation systems. 4. Design 4.1 Parts The twin radial blower consists of the following parts - motor, radial wheels, inner rings = fan unit - basic plate, half bowl, outer rings, motor holder - resistor with micro-temperature-fuse MTF, clip (for multilevel-versions) - cable set (for multilevel-versions)

3/7 4.2 Material All housing parts and radial wheels are made out of plastic granulate polyamide PA6, 35% glass-fibrereinforcement. This material is listed to UL concerning burning behaviour, has a high temperature-resistant and because of the glass-fibre-reinforcement a high stability. 4.3 Blower speed control The different blower speed are achieved using a resistor. The resistor is a cemented ceramic resistor. The blower is protected from overload and a possible burning danger with a micro-temperature- fuse (MTF) installed at the resistor. Wiring diagram blower for a 3-speed version Wiring diagram blower for a 4-speed version CAUTION! For the third blower speed level a fuse of 15A at 24V and/or 30A for 12V has to be set by the customer. 4.4 Cable set The used wires are unscreened low tensions wires with thin-wall isolation for road vehicles. FLRY with colour marking of wires according to DIN IEC 304.

4/7 5. Function The air enters axial into the fan wheel, then the air will be radial turned round and leaves on the area vertical to the suction direction. Note: the blower carbon brush is a wearing part. If the carbon brushes are outworn, defective or contaminated, the motor will not run or not in a suitable way. At any service interval (depending on usage situation) the blower function has to be checked and the blower has to be changed, if necessary. The check of the blower in a disconnected state: optical check on - physical damage on the housing, the air grille or the fan wheel - contamination, dust, corrosion and other, that impair the function stiffness Then a function check is recommended abnormal noises uneven running fluctuating current consumption a decrease of air flow rate blower don t run under voltage any more If one or more of these impairments apply, the blower function is not given any more and the blower has to be replaced. During check pay attention to the necessary safety advises (chapter 1) 6. Technical data DRG730 nominal voltage 12V/24V test voltage 13V/26V air discharge flow 730 m 3 /h acceptable ambient temperature -40 C to +85 C range weight ca. 1,8 kg isolation class B according to EN60335-1 speed 1 speed 2 speed 3 V air in m 3 /h 300 540 770 Pel in W 75 160 265 Lp in db(a) 55 66 73 cable colours: BN minus WH slow 1.speed RD medium 2.speed BK fast 3.speed

7. Dimensions DRG 730: Technical Information 5/7 8. Installation hole pattern for DRG 730:

6/7 Installation instructions: For reliable operation of the DRG, the maximum fan bracing of 1 mm are not exceeded. Provision shall be made for a suitably flat mounting surface. to illustrate: 9. Characteristic curve

10. Conducted validation tests for DRG-family (motors) 7/7 Test method Standard basis AU standard Short description Validation power measuring 963-38T-0010 evaluation air characteristic curve characteristics OK Sound intensity level test DIN IEC 651 963-38T-0011 sound intensity level free-blowing OK dust test 963-38T-0003 function at dust influence 1000h operation OK vibration test according to DIN IEC 68 963-38T-0007 vibration test 30...100Hz / max 8g OK IVECO 18-2105 10-200Hz/5g OK salt spray test DIN 50021 963-38T-0016 corrosion resistance 72h OK electr. Function test start-up test over voltage 32V 60 min OK polarity test OK Insulation test/electric strength 500V OK 963-38T-0012 run behaviour with resistor OK balance quality DIN ISO 1940 blower balanced OK temperature test storage DIN IEC 68 storage 95h /2h OK temperature test operation DIN IEC 68 72h at 85 C OK temperature test operation DIN IEC 68 500h at 80 C thermal shock test IVECO 18-2105 10 cycles 2h at -30 C/2h at 80 C OK temperature cycling test DIN IEC 68 35 cycles 8h between -40/+80 C OK climate test humidity constant DIN IEC 68 55 C at 95% air humidity 21 days OK climate test humidity cyclical DIN IEC 68 12 cycles of 24h at 10-80 C / 95% humidity OK cold test DIN IEC 68 function + storage at -40 C/72h OK arctic test MAN LH 259001 function + storage at -46 C OK EMC tests 2006/28 EC directive emitted interference / interference resistance OK electrostatic sensitive device tests MAN LH 259 001 electrostatic discharge OK lifetime test 963-38T-0008 Continuous operation, free-blowing at 13/26V max. load ca. 5000 h laboratory conditions