B - BEST O - ORIGINAL. R - Renown. N - Name. I n H e a t e r s

Similar documents
There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

Fired heaters for refineries and petrochemical plants. Presentation of our Projects

GROUP PRESENTATION 2016

Revamp Fired Heaters to Increase Capacity Use these guidelines to ensure a successful project

HOW TO BOOST THE PERFORMANCE OF FIRED HEATERS

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.

Trends for Radiant Tube Heated Strip Lines

Zeeco, Inc. Doc. No Tulsa, Ok Cover Page GLSF-14 Free-Jet and RWSF-4 Radiant Wall Burners. Range Fuels Soperton Plant, LLC

PROVIDING PROCESS EQUIPMENT SOLUTIONS TO CUSTOMERS FOR OVER 160 YEARS

Fired Heaters Key to Efficient Operation of Refineries and Petrochemicals

Beneficial Use of Landfill Gas for Leachate Evaporation and Power Generation

When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units.

PACKAGED COMMERCIAL WATERTUBE BOILERS

25 Years IBS GmbH. Innovative and taylormade burner systems

Madhu Honap HONEYWELL THERMAL SOLUTIONS INTRODUCTION

Burners Flares Incinerators Vapor Combustion

FURNACES & OVENS LEADING INNOVATORS IN THERMAL TECHNOLOGY TO THE OIL & GAS, CHEMICAL AND POWER INDUSTRIES ASSET INTEGRITY PARTNER

Heurtey Petrochem Manufacturing

A TRUE GAME CHANGER - The Vortex Heat Recovery Center CONDENSING EFFICIENCIES FOR TRADITIONAL BOILERS & HEATERS

Glossary. Carbon Dioxide (CO 2

Kolmetz Handbook of Process Equipment Design REFINERY FURNACE DESIGN, SIZING AND TROUBLESHOOTING (ENGINEERING DESIGN GUIDELINE

Fuel-Fired Vertical Tubeless Boilers

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer

FUEL-FIRED VERTICAL TUBELESS BOILERS

FOR THE PETROLEUM AND RELATED INDUSTRIES

INTEC Engineering GmbH Energy systems

Originators of the Flexible Water Tube design

Image_engl_08:Image-engl-RZ :55 Uhr Seite 1. INTEC Engineering GmbH Energy systems

clearfire Large capacity condensing boilers 4,000 to 12,000 MBTU/hr

BUDERUS. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. BUDERUS. G Cast Iron Commercial Boilers

Efficiency and Design Improvements in Multiple Hearth & Fluid Bed Incinerators

Thermal Fluid Heaters

Appendix A. Glossary of Common Terms

A M E M B E R O F T H E K E N D A L L G R O U P

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations.

INDUSTRIAL WATERTUBE BOILERS

Boiler Basics. Design and operation

G215 G315 Cast Iron Residential Boilers

WHAT IS A BOILER? BOILER IS AN EQUIPMENT WHICH PRODUCES STEAM AT THE REQUIRED PRESSURE AND TEMPERATURE. BOILER DESIGN, MANUFACTURE & INSTALLATION ARE

Helical Coil Heaters. Hot Oil Heaters Booster Heaters. CEI Enterprises

Originators of the Flexible Water Tube design

Development of Boiler Design

Energy Conservation. Chapter 16

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal

OIL AND GAS INDUSTRY

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

PUSHING THE LIMITS OF WHAT IS POSSIBLE

HEATEC PRODUCTS AND SERVICES FOR THE FOOD INDUSTRY

The Ultimate in Direct Contact Water Heating. by Thermal Engineering of Arizona, Inc. An Inc. 500 Company

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS

Boiler Draft Equipment

Overview of Gas Range Types

Process Simulation and Optimization of Cryogenic Operations Using Multi-Stream Brazed Aluminum Exchangers

REFERENCE SYLLABUS. For FIRED PROCESS HEATER OPERATOR S. CERTIFICATE of COMPETENCY EXAMINATION AB-239. Edition 3, Revision 1, Issued

GAS CONDENSING TECHNOLOGY

RHC GAS FIRED HEATING COILS

Amec Foster Wheeler- Fired Heater Division

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Indiana WX Oil Furnace Inspection Guide

Module 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments

SECTION HEATING BOILERS

Shell Martinez Refinery Callidus CUBL Burners

Originators of the Flexible Water Tube design

THE WORLD S FIRST FLAMELESS CRUDE HEATER

Brooders. Better Brooding for Your Chicks... Since 1924

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

NOx REDUCTION EXPERIENCE ON NATURAL GAS FIRED TURBO FURNACES

HTP s history of developing new and innovative products has allowed the company to grow over 18 % annually for the last 10 years.

Raypak Residential Products

2x58 MW Coal Fired Power Plant at Mauritius

Process Heat Equipment & Combustion Field Services Guide

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

INNOVATIVE CERAMIC PROCESS ENGINEERING

Exchangers. Air-cooled Heat. Exchangers

LOW-NOX BURNER RETROFIT CHALLENGE

The WCGH High Efficiency Commercial Water Heater with Storage Tank

IN THE PULP AND PAPER INDUSTRY

ecodry Figure 1 - Process Diagram ecodry B General Process Description

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

Packaged Marine Design Thermal Fluid (Hot Oil) Heaters

Efficient Steam System Design

HYDROCARBONENGINEERING June June 2015

Heat Recovery Units. Heat Recovery 1

Copper-Fin GAS-FIRED BOILERS

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

SPECIALIST FOR HEAT-EXCHANGER, FIN TUBES AND BOILER CLEANING SYSTEMS

DIRECT FIRED HOT WATER BOILER Atmospheric Gas Fired T Models 300,000 to 6,800,000 BTU Gas Fired

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Mechanical Engineering Department Sheet (1)

Zeeco recently had the opportunity

Downsizing after Retrofit

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

Copper-Fin GAS-FIRED WATER HEATERS

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

HEATEC PRODUCTS AND SERVICES THAT EXCEED YOUR EXPECTATIONS

A. Product Data: Include rated capacities, furnished specialties and accessories.

Water and ground source heat pumps 61WG kw. Heating

ENERGY OPTIMIZATION IN THE MAA GAS PROCESSING FACILITIES

Energy recovery from exhaust gases using Heat Pipe technology

INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207

Transcription:

B - BEST O - ORIGINAL R - Renown N - Name I n H e a t e r s

Comprehensive, Cost-Effective and Super-Efficient The Born Range of Products and Services Specialist Furnaces Hydrocracking Steam Reforming Sulfur Recovery Units EDC Cracking Furnaces Platformer Heaters High Temperature Pyrolysis Ethylene Cracking Furnaces Waste Heat Recovery Units for Turbine Exhaust Steam Superheaters Vacuum Units MTBE Feedstock Reformers Ammonia Reformers Hydrogen Reformers Cylindrical Heaters Helical Coil Radiant & Convection Twin Vertical Coil Radiant Vertical Tube Radiant & Convection Segmented Vertical Tube Radiant & Convection Helical Coil Radiant Vertical Tube Radiant Segmented Vertical Tube Radiant Box Type Heaters Horizontal Tube-Hipframe-Radiant Convection Vertical Tube Multi-Cell Twin Cell Horizontal Tube-Radiant Convection Horizontal Tube-Flat Roof-Radiant Convection Centre Tube Double Fired Multi-cell Vertical & Horizontal Tube Ancillary Equipment & Service Erecting & Commissioning Supervision Procurement & Inspection Services Consulting Services for Increased Efficiency Supply of Spare Parts Fuel Saving, De-Bottlenecking & Revamping Existing Furnaces Sootblower Selection & Economizer Section Cleaning Engineering Studies Air Preheat Systems Burner Management Systems Burner Selection & Control Systems Noise Attenuation Plenum Chambers NOx and SOX Reduction Services and Equipment Piping and Control Valves with Tie-ins Around The Heaters Computerized Piping Stress Analysis Computerized Structural Mechanical Analysis The best heaters are Born

Versatile!... The Popular Born Prefab... The Born Prefab heater is a tough, versatile unit that is shipped in completely assembled modules. It is available either with horizontal tubes or vertical tubes. The prefabricated and preassembled heater was developed in response to a demand for a process heater which could be shipped as a single entity or in modules or sections ready for field assembly. Units are available in sizes ranging from 200,000 BTU/hr to 500,000,000 BTU/hr. The unique feature of the Born Prefab heater is that it arrives at the job-site as completely preassembled units. This feature reduces field construction costs to the absolute minimum while at the same time giving quality process heater operation and efficiency. This unit has a true radiant tube section, thus assuring controlled radiant heat absorption, while the convection section insures high thermal efficiency. Design of the Born Prefab heater enables the natural flow of combustion gases upward from the burners with no obstructions, resulting in very low pressure drops so that adequate draft can be obtained with very short stack lengths. This Born design is based on over 90 years experience in designing and constructing heaters for the petroleum industry. This construction feature also allows an extremely accurate and sensitive control of the temperature of the outgoing fluid. Actual recorder charts of many furnaces now in operation show that the outlet temperature can be maintained within ½ of 1 degree Fahrenheit. The heater structure is a steel frame and will support the entire weight of the refractory walls, tubes, headers, breeching and stack. The stack is a self-supporting steel stack superimposed on the heater structure. All shielded walls are lined with insulating refractories tied to the steelwork. These are either ceramic fiber refractories or insulating castables. The elevated air-cooled floor is insulate and reinforced for ample beam strength. The interior area of the breaching, including explosion doors, is insulated. Access doors are provided for the combustion chamber, the breeching and stack. The famous Born Prefab heater eliminates field construction and offers top efficiency any time, any place, any size. Maximum efficiencies are obtainable with the Born Prefab heater. Flow of oil through the convection section of the heater is countercurrent to the hot flue gas, the coldest oil entering at the top of the heater and the hot oil passing out of the section at the bottom. With this type of process, the coldest oil absorbs the last available heat from the stack gas, which results in higher efficiencies. The special design and construction of the Born Prefab heater keeps the oil or other fluid being heated in the maximum temperature zone for a relatively short period of time. Heaters are not made they are Born

Useful Table and Charts Method of Estimating Temperatures Deg. C Deg. F Dark Blood or Black Red 532 990 Dark Red 566 1050 Dark Cherry 677 1250 Bright Cherry 745 1375 Light Red 816 50 Orange 899 1650 Light Orange 940 1725 Yellow 997 1825 Light Yellow 1080 1975 White 1204 2200 Dazzling White 00 2732 Gross and Net Heating Values of Simple Fuels Gross Heating Value Net Heating Value Fuel Symbol BTU/ft 2 BTU/lb BTU/ft 2 BTU/lb Carbon C 14,093 14,093 Hydrogen H 2 325.0 61,100 275.0 51,623 Carbon Monoxide CO 321.8 4,347 321.8 4,347 Sulfur S 3,982 3,892 Methane CH 4 1013.2 23,879 913.1 21,520 Ethane C 2 H 6 1792.0 22,320 1641.0 20,442 Propane C 3 H 8 2590.0 21,661 2385.0 19,944 Normal Butane n-c 4 H 10 3370.0 21,308 3113.0 19,680 Acetylene C 2 H 2 03.0 21,572 1453.0 20,840 Hydrogen Sulfide H 2 S 672.0 7,479 633.0 6,930 Determination of Furnace Efficiency with Born Nomograph DATA REQUIRED: By Orsat analysis determine percentage of CO 2 and O 2 in stack gases and stack temperature F Directions: Connect CO 2 and O 2 with a straight edge. The straight edge will fall over reference points on lines 2,3,4,5 and 6. Line 2 indicates the latent heat loss due to burning of H 2 in fuel and also shows Hydrogen/Carbon ratio by weight of fuel. The straight edge must fall on the proper H/C point on line 2 for the particular fuel being burned. Line 5 shows the sensible heat loss to the stack in terms of percent/100 F of stack temperature. Line 6 indicates the percent excess air in the sample tested. Example: 0.6 sp.gr. Natural Gas H/C = 0.31 (N 2 and CO 2 free) Orsat Data: CO 2 = 9.2% O 2 = 5.2% Stack Temp.: 810 F - 60 F Ambient Temp. = 750 Rise Stack Loss: Latent Heat 8.75% Sensible Heat 2.39 x 7.5 = 17.95% Total Loss: (Gross Heat Basis) 17.95 + 8.75 = 26.70% Total Loss: (Net Heat Basis) = 17.95 x 100 = 19.65% (100-8.75) Radiation Loss: to be added Furnace efficiency on either the gross or net heat basis is determined by subtracting the above losses from 100%. Note: The nomograph may also be utilized in the same manner if only the percentage of O 2 in the stack gas is known, provided the H/C ratio is known, or calculated. Average HIC rations are as follows: Natural Gas 0.31-0.33 Refinery Gas 0.25-0.28 12 API Fuel Oil 0.117 Coal 0.05-0.07

Vertical Cylindrical Heaters These heaters can have either helical coils or serpentine coils depending on your specific requirements and most suitable design solution to meet them. The type of heater offered is carefully selected to feature low capital cost, high efficiency, close control and trouble free operation. Reformers Born manufactures steam reformers utilizing technology supplied by companies such as Haldor Topsoe, etc. They can be down fired or side fired depending on your requirements and the technology to be used. The tubes are spun cast alloys. Refractory linings are suitable for high temperatures and include ceramic fiber modules. UOP Platform Heaters This platform heater was fully modularized and delivered to the site by barge. The four radiant cells are complete with U tube assemblies, manifolds, burners and refractories and the convection section and stack were fully modularized. To reduce the expense of these high cost capital items, Born source the materials worldwide. The barge took the platformer to the quayside local to the refinery. It was then transported to the foundations prepared for it and was lifted straight into position. Heaters With Air Pre-Heat System This air preheat system preheats the combustion air to increase overall efficiency by means of an air heater which utilizes the hot flue gases. The cool flue gases are then passed through an induced draft fan and exhausted to a stack and the combustion air is supplied via a forced draft fan. These units can be either recuperative or regenerative type. More and more heaters are Born everyday

Unequaled Service plus Facilities... Quality Control Complete service facilities supplied by Born for over 90 years assures our Clients of experienced personnel when service issues arise. Quality control The Born organization comprises of a design department, engineering department, drafting department, consulting engineers, project management teams, procurement staff, Quality Assurance staff, Quality Control department as well as a full marketing and sales team. All our personnel are fully trained to ensure that every heater is designed, supplied and delivered in accordance with our high-quality standards and the contract requirements. Fabricating Born Inc. has its own fabrication facility in Tulsa, OK. Born Inc. can also fabricate heaters in qualified approved fabrication shops that are selected on a contract by contract basis considering final destination, contract size and any particular Client requirements. Wherever Born heaters are fabricated all work is undertaken under the direct supervision of Born engineers and Quality Control personnel. Engineering A full staff of highly-trained mechanical, structural, and process engineers are available to serve you in any heater issues that may arise. Research Continuous research in the field, laboratory and engineering departments of the company keep the Born heater a leader in the heater field. Heaters are not made they are Born

Born is the world s leading authority in fired heater technology. It has been so for over 90 years since the inspirational pioneering work of the founder of the company, Dr. Sidney Born. He was born in 1889, received his Ph.D. in 1913, and went on to develop a new thermal oil cracking process which launched his reputation into the petro-chemical industry. Born Inc. is a family run business through three generations of the Born family. The current CEO is Dr. Sidney L. Born the grandson of the founder. Born s continued concentration on process heaters and furnaces for a petro-chemical industry is the real strength of the company. It engineers, manufactures, inspects, installs, commissions and provides ongoing advice and maintenance. Our reputation is second to none. The Benefits of Born ª Low Initial Cost. You will benefit from over 90 years of experience during which we have become the market leaders in designing the most economical heaters to your specifications. Our designs coupled with our worldwide procurement result in our being able to provide efficient competitive heaters without sacrificing quality. ª High Efficiency. Born heaters are designed to fit your specific requirements and achieve the very highest efficiencies obtainable. Where inlet temperatures are low enough, these high efficiencies can be achieved by the proper design of the convection section. In other cases, heaters are designed which recover heat from gas turbine exhaust or other available high temperature gases. Born has designed many heaters utilizing air preheat and have one of the only installations in the world with a single air preheater servicing two different heater services. Born has been the leader in designing heaters to save on the rising fuel costs long before the energy crisis became a common phrase. ª Low Operating Cost. The counter-current flow of a Born heater reduce fuel costs while providing high efficiencies. Careful design and construction details keep operating costs low in a Born heater. Heat recovery units are installed in all types of services, including recovery heat, process preheat and air preheat. ª Lower Maintenance Cost. Born heaters offer the lowest maintenance and upkeep costs in the heater due to their proven efficient design and material selection. ª Use Less Space: Easily Serviced. The compact design of Born Heaters, especially the vertical tube heater, offers high efficiency units where space is critical. Construction design of the heaters allows easy, quick servicing. The highly-trained Born technicians are available for any on-site services you may require. ª Maximum Utilization of Fuel for Combustion. Born engineers are specialists in selecting the proper number, size and arrangements of burners for the very best combustion efficiency. This can be accomplished by floor firing, end firing, or side firing depending on the type of fuel to be burned. ª Environmentally Sensitive. Born can supply heaters conforming to the most stringent environmental control standards, including noise, NOx and SOx, etc. The impossible is achievable with a Born heater

20.9 20 BORN 20.9 20 19 19 18 18 17 16 00 1000 17 16 Percent CO 2 by Volume 13 12 11 10 9 8 7 6 5 4 3 14 13.20 3 4 5.10 6. 7.20 8.25.30 9.35.40 10.45.50 11.60.70 12.80.90 1.00. L H =Latent Heat loss from H 2 Percent Heat Developed 0 12.05 32 60 80 90 100 110 120 130 135 140 145 0 5 Dew Point of Combustion Products of Dry Fuel & Air 50 40 30 25 20 14 13 12 11 10 9 8 7 W G = lb of Gas per 10,000 BTU in Fuel Burned 10.0 9.0 8.0 7.0 6.0 5.0 4.5 4.0 3.5 3.0 500 400 350 300 250 200 0 140 130 120 110 100 90 Gass Loss Percent per 100 F W G C P = Thermal Capper 10,000 BTU in Fuel 2.5 2.0 80 70 100A E = Percent Excess Air 60 55 50 45 40 35 30 25 13 12 11 10 9 8 7 6 5 4 3 Percent O 2 by Volume 2.30 2.40.50.60 160 1.00 0 0 1 2 3 4 5 6 7 20 10 6 5 0 The Impossible is achievable with a Born heater

100 90 80 70 60 Gas Combustion Chart 50 Percentage of Net Heating Value Contained in Flue Gas (Basis 60 F) 40 30 25 20 Excess Air (%) 10 9 8 7 6 5 100 50 25 0 250 300 400 500 600 800 1000 00 2000 2500 Temperature of Flue Gas ( F) Heaters are not made they are Born

100 90 80 70 60 Fuel Oil Combustion Chart 50 40 Percentage of Net Heating Value Contained in Flue Gas (Basis 60 F) 30 25 20 Excess Air (%) 10 9 8 7 6 5 4 100 50 25 0 3 200 250 300 400 500 600 800 1000 00 2000 2500 Temperature of Flue Gas ( F) More and more heaters are Born everyday

Born Born Inc. P.O. Box 102 Tulsa, OK 74101-0102 USA Tel: 1-918-582-2186 Fax: 1-918-582-5163 E-mail: info@borninc.com www.borninc.com