Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

Similar documents
DEEPAK PALIWAL, S.P.S.RAJPUT

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

International Journal of Multidisciplinary Research and Modern Education (IJMRME) ISSN (Online): (

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

CHAPTER 1 INTRODUCTION

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

Experimental study of R600a and R436a to replace R134a in a domestic refrigerator and freezer

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

International Engineering Research Journal (IERJ) Special Issue Page , June 2016, ISSN

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

Study of Behavior of Refrigerant Mixtures in Domestic Refrigerator- Practical Research

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

HFC/HC BLEND FOR CAR CLIMATE CONTROL WITH MINERAL OIL AS LUBRICANT

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

EXPERIMENTAL INVESTIGATION OF A REFRIGERATOR BY USING ALTERNATIVE ECO FRIENDLY REFRIGERANTS (R600A & HC MIXTURE)

International Journal of Advance Engineering and Research Development

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

Department of MCE, Islamic University of Technology 2. Abstract

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

Experimental investigation on the performance of air conditioner using R32 Refrigerant

Eco-Friendly Refrigerants as Substitutes for HFC134a - a Review Deepak Paliwal

Assessment of LPG as a possible alternative to R-12 in domestic refrigerators

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Performance Prediction of Domestic Refrigeration System using R436A Refrigerant as alternative Refrigerant to R134a with ANN

Design of LPG Refrigeration System

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

A Review Paper on Comparative Study of Household- Refrigerator with Alternative Low Global Warming Potential Refrigerants

Pure Butane as Refrigerant in Domestic Refrigerator Freezer

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

ENERGY PERFORMANCE ASSESSMENT OF R134A/LPG BLEND AS REPLACEMENT OF R134A IN VAPOR COMPRESSION REFRIGERATION SYSTEM

JJMIE Jordan Journal of Mechanical and Industrial Engineering

CHAPTER 1 INTRODUCTION

Experimental Investigation on R 290 and R 600a In a Vapor Compression Refrigeration

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

THERMODYNAMIC AND THERMOPHYSICAL ASSESSMENT OF HYDROCARBONS APPLICATION IN HOUSEHOULD REFRIGERATOR

A Review on selecting an Eco-friendly Refrigerant alternate to R134a in Domestic Refrigerators

Enhancement of COP using Nanoadditives in Domestic Refrigerator

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Refrigerants Retrofit as Alternative for R12 and R134a in Household Refrigerators

Oyelami S., Bolaji B. O.

Design and Fabrication of Liquefied Petroleum Gas Refrigeration System and Comparison with Domestic Refrigerator

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

R134a Refrigerant in Vapour Compression Cycle: A Review Paper

FABRICATION OF REFRIGERANT FLOW RATE WITH SPIRALLY COILED CAPILLARY TUBE

International Journal of Informative & Futuristic Research ISSN (Online):

LPG Refrigerator. October 2017 IJIRT Volume 4 Issue 5 ISSN:

η second law = Second law efficiency

A Comparison Between Refrigerants Used In Air Conditioning

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

BUTANE, ISOBUTANE AND THEIR MIXTURES AS AN ALTERANTIVES TO R-134a IN DOMESTIC REFRIGERATOR

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

Experimental performance evaluation of vapour compression refrigeration system without nano particles

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

VCR SYSTEM USING R-600a/ POE OIL/MINERAL OIL/NANO-SiO 2 AS WORKING FLUID: AN EXPERIMENTAL INVESTIGATION

ADVANCES in NATURAL and APPLIED SCIENCES

PERFORMANCE OF A VERY LOW TEMPERATURE REFRIGERATION SYSTEM OPERATING WITH NATURAL FLUIDS

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

Sarthak Thakar, 2 R.P.Prajapati 1

ENERGY, EXERGY AND SUSTAINABILITY ANALYSIS OF TWO-STAGE VAPOUR COMPRESSION REFRIGERATION SYSTEM

EXPERIMENTAL ANALYSIS OF MICROCHANNEL CONDENSER USING R134a AND DROP IN SUBSTITUTE HYDROCARBON MIXTURE OF R290 AND R600a

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

STUDY AND PERFORMANCE ANALYSIS OF ECO-FRIENDLY REFRIGERANT FOR RETROFITTING R22 IN RESPECT TO BANGLADESH

IJESRT. (I2OR), Publication Impact Factor: (ISRA), Journal Impact Factor: 2.114

Experimental Investigation of COP Using Hydro Carbon Refrigerant in a Domestic Refrigerator

Performance Investigation of Domestic Refrigerator Using Pure Hydrocarbons and Blends of Hydrocarbons as Refrigerants

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Transcription:

IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 14, Issue 1 Ver. V (Jan. - Feb. 2017), PP 75-82 www.iosrjournals.org Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a Dr. Deepak Paliwal (Mechanical Engineering Department, S. V. Polytechnic College Bhopal, India) Abstract: Refrigerant R134a base systems has higher GWP value that's why the conversion of same into ecofriendly system is the major concern for refrigeration industry. This investigation focuses on mixture ratio of pure hydrocarbon R290 and R600a used in 200 liter domestic refrigeration system by certain changes in mass ratio of refrigerants. In the present work, first of all the effect of mass ratio of HCM refrigerants on the performance of the system was investigated. HCM of R600a/R290 (60/40 by wt. %) gave better performance than that of HCM R600a/R290 (70/30 by wt. %), R600a/R290 (50/50 by wt. %) and R134a. The mass ratio of HCM (R600a/ R290) refrigerants was optimized for the performance parameter with respect to evaporating temperature. The COP of R600a/R290 (60/40 by wt. %) mixture was higher than that of R600a/R290 (50/50 by wt. %) by 21.9% and 17.6% at -5 0 C and 5 0 C evaporative temperature respectively. COP decreased as propane mass fraction in HCM increased above 40%. Keywords: Refrigerant, R134a, Pull down, COP, R600a/R290, HCM. I. Introduction Refrigeration goes back to ancient times where storage of ice, evaporation of water, and other evaporative processes were prevailing. More specifically, refrigeration is that branch of science which deals with the process of decreasing and maintaining the temperature of any space or material below the temperature of the atmosphere[1]. According to ASHRAE, it is defined as the science of providing and maintaining temperature below that of surroundings [2]. For the past half century, CFCs have been used extensively in the refrigeration sector. (CFCs) and hydrochlorofluorocarbons (HCFCs) became the most dominant types of refrigerants due to their properties of non- corrosiveness, non-flammability, non-toxicity and non-irritability[3]. The problems occurred, when in 1974, Molina and Rowland, reported and published their ozone depletion hypothesis in which they claimed that the chlorine element catalytically destroyed the ozone layer in the stratosphere [4]. Since the advent of the Montreal Protocol, however, Refrigeration sector has been find out solution for ozone depleting substances. Alternative to CFCs refrigerants are HFC-152a, HFC-134a, MP66/39, HC-290/600a etc. These days, the concern for the greenhouse warming has never been greater. HFC-134a is non-flammable and has zero ozone depletion potential but serious GWP[5]. Thus, in 1997 the Kyoto Protocol was signed by many nations calling for the reduction in emissions of greenhouse gases including HFCs. There has been much resistance in adopting HFC134a for refrigeration equipment by some environmental groups. European countries are uses hydrocarbon in pure or mixed form on their refrigerator in early of 2000. Hydrocarbon refrigerants are flammable[6]. They have zero ozone depletion potential and a greenhouse warming potential approaching zero. Many researchers have reported performance evaluation of hydrocarbon mixtures by both experimental and simulation methods [1-5]. India and China are the largest refrigerator demanding countries in the world, have been quite active in the application of hydrocarbons in domestic refrigerators. The assessment of alternative refrigerants is a difficult task[7]. Several criteria must be considered while selecting alternative refrigerants. The experimental work carried out in this area is also extensive. Many drop-in tests are being carried out to check the performance of replacement refrigerant in existing machines, designed for CFCs, HFCs and HCFCs[8]. II. Literature survey Y. S. Lee et al.[9] did an experiment and tested Iso-butane in domestic refrigerator. The compressor input power varies from 230 and 300 W, while the refrigerant charged was about 150 g. It was found that the COP lie between 0.8-3.5 in freezing application. This study focused only on the performance of a VCR system with R600a as the alternative refrigerants. B. Tashtoush et al. [10] conducted an experiment with the aim to analyze hydrocarbons (R600/R290/R134a) at various quantities in R12 domestic refrigerator. The results shows that Butane/Propane/R134a mixtures provide excellent performance parameters, such as COP of refrigerators, compression power, volumetric efficiency, condenser duty, compressor discharge pressure and temperature, relative to a 210 g charge of R12. S. Joseph Shekhar et al. [11] had performed experimental analysis on a 165 liter, CFC-12 based domestic refrigerator retrofitted with eco-friendly refrigerant mixture of HFC134a / HC290 / HC600a without changing the mineral oil. The system had been running successfully for more than 12 months, DOI: 10.9790/1684-1401057582 www.iosrjournals.org 75 Page

Experimental Evaluation of Refrigerant Mixtures As Substitutes For Hfc134a thus it was observed that the new mixture was compatible with mineral oil. The improvement in theoretical analysis of COP and actual COP were found out from 3 to 12% and 3 to 8%, respectively. M. Fatouh et al. [12] had used LPG i.e. mixture of 60% propane and 40% commercial butane for drop-in replacement of HFC134a, in a single evaporator domestic refrigerator with a volume of 10 ft 3. Highest actual COP, lowest on-time ratio and lowered electric consumption were achieved in LPG refrigerator than that of R134a by 7.6%, 14.3% and 10.8%, respectively. Hence, it can be concluded that the proposed LPG shown to be an appropriate and long-term alternative refrigerant to replace R134a in the existing refrigerator. K.Senthil Kumar et al. [13] experimentally tested HC mixture (30%R290 & 70%R123) and computationally replacing R12 in this work, to overcome the above said problem, in a refrigerant mixture R290 has been identified as suitable for combination with R123.. It is observed that the difference of pressure and temperature characteristics disappears as the R290 mass fraction is increased from 10% to 30% with R123 and the curve almost matches the R12 curve, which symbolized that mixture 7/3 can exhibits similar properties and could be used as a substitute for CFC-12. M. Mohanraj et al. [14] studied that domestic refrigerator uses HFC134a as refrigerant, due to its excellent thermodynamics and thermal- physical properties. But, HFC134a has high global warming potential (GWP) of 1300. This paper presents experimental results of an energy-efficient hydrocarbons (HC) mixture consisting of 45% HC290 and 55% HC600a as a drop-in substitute for HFC134a as various mass charges of 40 g, 50 g, 70 g and 90 g in domestic refrigerators. The results practically showed that the 70 g mixture as barrier of COP, lower power consumption, lower pull-down time and lower discharging temperature than HFC134a. The miscibility of synthetic oil with HC refrigerant mixture was also found to be good. K. Mani et al. [15] done an experiment and analyzed that the performance study on a VCR system with the new refrigerant mixture R290/R600a as a drop-in replacement was with CFC-12 and HFC134a. Experimental results showed that the refrigerant effect of R290/R600a (68/32 by wt. %) mixture was higher than that of R12 in the range of 19.9% to 50.1% at the lower evaporating temperature and in the range of 21.2 to 28.5% at the higher evaporating temperatures, respectively. COP of R290/R600a mixture increased from 3.9% to 25.1% at lower evaporating temperatures than that of R12 and COP of R290/R600a mixture increased from 11.8% to 17.6% at higher evaporating temperatures to than that of R12. The refrigerant R134a showed slightly lower coefficient of performance than R12. The R290/R600a (68/32 by wt. %) mixture can be considered as a drop-in replacement refrigerant for CFC-12 and HFC134a refrigerants. III. Experimental setup An experimental set-up for vapor compression refrigeration system was designed to investigate the performance of R134a, R600a, R600a/R290 (70/30 by wt. %), R600a/R290 (60/40 by wt %) and R600a/R290 (50/50 by wt %) mixture refrigerants. Fig.1 shows actual view of the experimental set-up and Fig.2 shows line diagram. The system was a 200 liter domestic refrigerator ( with deep freezing capacity ) that was originally designed for 150g R134a mass of refrigerant. It consists of two loops, the main loop consist of a compressor, a condenser, a filter-drier, a expansion device and a calorimeter, and second loop consisted of a evaporator instead of calorimeter with all other main equipments. Hermetically sealed reciprocating compressor recommended for R134a refrigerant of 200 liter refrigerator (with deep freezing capacity) was used in the system. A force convection air - cooled condenser was used. Capillary tube of 10 feet length, and 0.036 inches diameter was used as expansion device in the system. Refrigerating effects of the system calculated by a calorimeter connected in the main loop. It consisted of a cooling coil of 25 feet length and 5/16 inches diameter, temperature measuring device, a electric heater by motor and a stirrer rotted for maintaining equal temperature in the calorimeter. All these devices were properly placed in a insulated plastic container having 10 liter ethylene glycol. The calorimeter was fitted with an electric heater and a dimmerstat (attached with wattmeter) to calculate R.E. (heat gain by heater will be equal to heat removed by evaporator coil). All these 9 thermocouples in the accuracy range of -50 ºC to 80 ºC with ± 0.1 ºC were fitted at inlet and outlet of all the major components. A drier was used after condenser to absorb moisture present in the refrigerant. In two pressure gauges, one is compound pressure gauge which is measured from -30 psi to 500 psi and one normal pressure gauge which is measured form -30 psi to 150 psi with ± 1 psi accuracy fitted at compressor discharge and suction side, respectively. Compressor power consumption was measured by a wattmeter with an accuracy of ± 0.5%. Energy consumption by the heating coils (inside calorimeter) was measured by a wattmeter with an accuracy of ± 0.5 %. Energy supply meter also used to calculate total energy consumption in KW/hr. DOI: 10.9790/1684-1401057582 www.iosrjournals.org 76 Page

Experimental Evaluation of Refrigerant Mixtures As Substitutes For Hfc134a Figure 1: Actual view of experimental set-up for VCR system. Figure 2: Line diagram of the experimental set-up for VCR system. IV. Experimental procedure The system was evacuated up to the negative pressure -20 psi to eliminate impurities, moisture and other foreign materials present inside the system by using vacuum pump, which might affect the accuracy of the experimental set-up. Then the refrigerator was charged in different mass fraction with the help of electronic weight m/c and charging valves. Initially we used 250g R134a refrigerant to calculate values for base line test. After that 125g HCM in different mass fractions we used to find out best refrigerant for the system. In all, measurements are taken when the system reached steady state condition (calorimeter temperature was maintained for 10 minutes at measured value temperature with the help of dimmerstat). Temperatures were recorded after every 10 minute interval in 0 C by 9 thermocouples, which are placed in all major equipments. Pressure at suction and discharge side of the compressor were also measured by two pressure gauges, after every 10 minute interval. To calculate pull down test system was cooled up from atmospheric temperature to desired temperature. R.E. at particular evaporating temperature was found by maintaining calorimeter, at that temperature with the help of heating device. In this process, wattmeter attached with calorimeter gave R.E. and wattmeter attached with compressor gave power consumption. The process was repeated for every refrigerants which were tested at all measured evaporating temperature. DOI: 10.9790/1684-1401057582 www.iosrjournals.org 77 Page

Calorimeter Temperature C Experimental Evaluation of Refrigerant Mixtures As Substitutes For Hfc134a V. Result and Discussion Experimental results obtained from pull down test with respect to time in minutes and performance parameters such as refrigerant effect, energy consumption, COP etc. with respect to evaporating temperature were analyzed for 125 g HCM R600a/R290 (50/50 by wt%), R600a/R290 (60/40 by wt %), R600a/R290 (70/30 by wt. %) and compared these with 250 g R134a refrigerant to optimize mass ratio of the HCM refrigerant for the system. Experiments were conducted at ambient temperature of 30 ºC. 1. Pull down characteristics - Fig.3 shows the variation of calorimeter temperature with respect to time. The temperature of ethylene glycol (10 liter) was reduced from 20 ºC for a period of 60 minute (continuous running test). The tests were conducted for different lengths of the capillary and refrigerants. In the entire range of operation minimum temperature was obtained for HCM 50/50. It is due to the fact that with increase in propane mass fraction, refrigerant mass flow rate increases M. Fatouh et al. [16]. It was observed that of continuous running test for 60 minutes on VCR system, the lowest temperature in calorimeter was measured to be -5.8 ºC for refrigerant 125 g of R600a/R290 (50/50 by wt.%). The second lowest temperature was observed to be -5.2 ºC for 125 g of R600a/R290 (60/40 by wt. %). Calorimeter temperature of 250 g R134a was found to be - 4.5 ºC in 60 minutes continuous running test. Results indicated that the cooling rate increased with the increase of mass percentage of R290 in refrigerant mixtures due to higher cooling capacity of R290 than other refrigerants. The nature of the graphs is similar as reported by Chao-Chieh Yu et al. [17]. 20 15 10 5 0-5 -10 0 10 20 30 40 50 60 Time in Minute Fig. 3: Variations of calorimeter temperature with respect to the time (in minutes), at 30 ºC ambient temp. (Continuous Running Test). 2. Refrigerating effect -Fig. 4 shows the effect of evaporating temperatures on the R. E. for the refrigerants 250 g R134, 125 g R600a/R290 (70/30wt.%), 125 g R600a/R290 (60/40 by wt.%) and 125 g R600a/R290 (50/50 by wt.%), at the capillary length of 10 feet. It was observed that in the tested range of evaporating temperatures, the R.E. increases with the increase in evaporating temperatures and was found to be maximum for the 125 g R600a/R290 60/40. It is due to the fact that with increase in propane mass fraction refrigerant mass flow rate increases M. Fatouh et al. [16,38]. R. E. for HCM R600a/R290 (60/40 by wt. %) was higher than that of R134a by 10% and 35.8 %,at -5 ºC and 5 ºC evaporating temperatures, respectively. The percentage increase in R. E. for R600a/R290 (60/40 by wt. %) was 13.7% and 7.7% than that of R600a/R290 (50/50 by wt. %), at -5 ºC and 5 ºC evaporating temperatures, respectively. The percentage increase in R. E. for R600a/R290 (60/40 by wt.%) was 65% and 21.3% than that of R600a/R290 (70/30 by wt.%), at -5 ºC and 5 ºC evaporating temperatures, respectively. Refrigerating effect was found to be higher for R134a at lower evaporating temperature than that of HCM 70/30 and 50/50, because mass flow rate of refrigerant is directly proposal to R. E. The nature of the graphs was similar as reported by A. S. Dalkilic et al. [18]. DOI: 10.9790/1684-1401057582 www.iosrjournals.org 78 Page

Compressor Work (W) Refrigerating Effect (W) Experimental Evaluation of Refrigerant Mixtures As Substitutes For Hfc134a 275 250 225 R600a/R290[70/30 by wt.%](m-125g) R600a/R290[60/40 by wt.%](m-125g) R600a/R290[50/50 by wt.%](m-125g) 200 175 150 125 100 75 50 Evaporating Temperature C Fig. 4 : Variations of refrigerating effect with respect to the evaporating temperature, at 30 ºC ambient temperature. 3. Compressor energy consumption - Fig.5 shows the effect of evaporating temperatures on power consumption for the refrigerants 250 g R134, 125 g R600a/R290 (70/30 by wt.%), 125 g R600a/R290 (60/40 by wt.%) and 125 g R600a/R290 (50/50 by wt.%), at the capillary length of 10 feet. It was observed that the power consumption was maximum for the R134a due to its higher mass flow rate. Power consumption was minimum for the mixture R600a/R290 (70 / 30 wt. %) due to the lower mass percentage of R290 in HCM. It was evident that the energy consumption by the compressor increased slightly with change in the evaporating temperature. Energy consumption by the system with refrigerants R134a and R600a/R290 (50/50 by wt %) were higher than that of R600a/R290 (60/40 by wt.%) by 39.2% and 43.3%, and 7.14% and 9.16%, respectively at -5 ºCand 5 ºC evaporating temperatures. It is due to the fact that with increase in propane mass fraction, refrigerant mass flow rate increases. The mass flow rate is directly proportional to the compressor work. 200 180 160 140 120 100 80 Evaporating Temperature C Fig. 5: Variations of energy consumption with respect to the evaporating temperature, at 30ºC ambient temperature. DOI: 10.9790/1684-1401057582 www.iosrjournals.org 79 Page

Pressure Ratio (P1/P2) Coefficient of performance (COP) Experimental Evaluation of Refrigerant Mixtures As Substitutes For Hfc134a 4. Coefficient of performance (COP) -Fig.6 shows the effect of evaporating temperature on the COP for the refrigerants 250 g R134, 125 g R600a/R290 (70/30 by wt.%), 125 g R600a/R290 (60/40 by wt.%) and 125 g R600a/R290 (50/50 by wt.%). It was evident that the COP increases considerably with the increase of evaporating temperature except for R134. It was also observed that the COP was the highest for the refrigerant R600a/R290 (60/40 by wt.%) than that of other refrigerants. It was also observed that the COP of R600/R290 (60/40 by wt %) mixture was higher than that of R134a by 53.1% and 72.3% at -5 ºC and 5 ºC evaporating temperatures, respectively. The COP of HCM R600/R290 (60/40 by wt %) was higher than that of R600a/R290 (50/50 by wt. %) by 21.9% and 17.6% at -5 ºC and 5 ºC evaporating temperatures, respectively. The COP of HCM R600/R290 (60/40 by wt. %) was higher than that of HCM R600a/R290 (70/30 by wt.) by 59.1% and 19.3% at -5 ºC and 5 ºC evaporating temperatures, respectively. It can be seen that the COP decreases as propane mass fraction in HCM increases above 40%. The main reason behind this trend is the rate of change in specific work, which is higher than that of cooling effect. 2.50 2.25 2.00 1.75 1.50 1.25 1.00 0.75 0.50 0.25 Evaporating Temperature C Fig. 6: Variations of coefficient of performance with respect to the evaporating temperature, at 30 ºC ambient temperature. 5. Pressure ratio (P 1 /P 2 ) - The desirable property of the refrigerant is that pressure should be low due to its minimize leakages past the compressor piston. The pressure ratio was maximum for the refrigerant R134a and was minimum for HCM R600a/R290 (70/30 by wt.%) at the capillary length of 10 feet. The pressure ratio for R600a/R290 is minimum due to its lower mass flow rate. 12 11 10 9 8 7 6 5 4 Evaporative Temperature C Fig. 7: Variations of compressor pressure ratio P 1 /P 2 (Discharge / Suction). DOI: 10.9790/1684-1401057582 www.iosrjournals.org 80 Page

Compressor Discharge Temperature C Experimental Evaluation of Refrigerant Mixtures As Substitutes For Hfc134a 6. Compressor Discharge Temperature - Compressor Discharge Temperature always be higher for HFC134a refrigerant but you can see in graphs the value of discharge temperature was quit low for HCM because lower mass of refrigerants as well as better cooling tendency and lower vapor pressure of R600a in HCM than other tested refrigerants. This is also give advantage for consumption of lubricating oil also low for HCM. 70 65 60 55 50 45 40 35 30 Evaporating Temperature C Fig. 8 : Variations of compressor discharge temperature with respect to the evaporating temperatures. VI. Conclusion The lowest temperature in calorimeter was measured to be -5.8 ºC for the refrigerant of 125 g of R600a/R290 (50/50 by wt %) and the second lowest temperature was obtained to be -5.2 ºC for 125 g of R600a/R290 (60/40 by wt. %). R.E. of HCM refrigerant R600a/R290 (60/40 by wt. %) was increased by 10% and 35.8% than that of R134a, at -5 ºC and 5 ºC evaporating temperatures, respectively. Percentage increase in R.E. for R600a/R290 (60/40 by wt. %) was 13.7% and 7.7% than that of R600a/R290 (50/50 by wt. %), at -5 ºC and 5 ºC evaporating temperatures, respectively. Power consumption was maximum for R134a due to its higher mass flow rate. Power consumption was minimum for the mixture R600a/R290 (70/30 by wt. %) due to the lower mass percentage of R290 present in that. Energy consumption for the refrigerants R134a and R600a/R290 (50/50 by wt. %) was higher than that of R600a/R290 (60/40 by wt. %) by 39.2% and 43.3%, and 7.14% and 9.16%, respectively at -5 ºC and 5 ºC evaporating temperatures. COP of HCM R600/R290 (60/40 by wt. %) was higher than that of R134a by 53.1% and 72.3% at -5 ºC and 5 ºC evaporating temperatures, respectively. COP of HCM R600/R290 (60/40 by wt. %) mixture was higher than that of R600a/R290 (50/50 by wt. %) by 21.9% and 17.6% at -5 ºC and 5 ºC evaporating temperatures, respectively. COP decreased as propane mass fraction in HCM increased above 40%. The pressure ratio was the maximum for the refrigerant R134a and was in minimum for HCM R600a/R290 (70/30 by wt. %) at the capillary length of 10 feet. References [1]. Roy J. Dossat, Principles of refrigeration, 4 th edition. Pearson education (Singapore) Pte. Ltd.,2003, New Delhi. Manohar Prasad, Refrigeration and air conditioning, 2 nd edition. New Age International publishers, 2010, New Delhi. [2]. E. Halimic, D. Ross, B. Agnew, A. Anderson, and I. Potts, A comparison of the operating performance of alternative refrigerants. Applied Thermal Engineering 23 (12) (2003), 1441-1451. [3]. M. Mohanraj. S. Jayaraj, C. Muraleedharan, Environment friendly alternatives to halogenated refrigerants- a review, Int. Journal Greenhouse Gas Control 3 (2009), 108-119. [4]. M. Mohanraj. C. Muraleedharan, S Jayaraj, A review on recent developments in new refrigerant mixtures for vapor compression based refrigeration air conditioning and heat pump units Int. J Energy. Res 35 (8) (2011), 647-669. [5]. Kyoto protocol, United Nations Framework Convention on Climate Change, United Nations, New York, USA, 1997. [6]. Dr. S. Forbes Pearson, New, Natural and Alternative Refrigerants, Star refrigeration Limited, 2013 Edinburgh. [7]. D. Jung, Chong-Bo Kim, Kilhong Song, Byoungjin Park, Testing of propane / iso-butane mixture in domestic refrigerators, International Journal of Refrigeration, 23 (2000), 517-527. [8]. Y.S. Lee, C. C. Su, Experimental studies of iso-butane (R600a) as the refrigerant in domestic refrigeration system. Applied Thermal Engineering 22 (2002), 507-519. [9]. B. Tashtoush, Tahat, M., Shudeifat, M.A, Experimental study of new refrigerants mixture to replace R12 in domestic refrigerators, Applied Thermal Engineering 22 (2002), 495-506. DOI: 10.9790/1684-1401057582 www.iosrjournals.org 81 Page

Experimental Evaluation of Refrigerant Mixtures As Substitutes For Hfc134a [10]. S. J. Sekhar, D. Mohan Lal, and S. Renganarayanan, Improved energy efficiency for CFC domestic refrigerators retrofitted with ozone-friendly HFC134a/HC refrigerant mixture, International Journal of Thermal Sciences, 43 (3) (2004), 307-314. [11]. M. Fatouh, M. kafafy, Experimental evaluation of a domestic refrigerator working with LPG, Applied Thermal Engineering 26 (2006), 1593-1603. [12]. K. Senthil Kumar, K. Rajagopal, Computational and experimental investigation of low ODP and low GWP HCFC-123 and HC-290 refrigerant mixture alternate to CFC-12, Energy Conversion and Management 48 (2007),3053-3062. [13]. M. Mohanraj, S. Jayaraj and C. Muraleedharan, Improved energy efficiency for HFC 134a domestic refrigerator retrofitted with hydrocarbon mixture (HC 290 / HC 600a) as drop-in substitute, Energy for Sustainable Development 11,4 (2007), 29 33. [14]. K. Mani, V. Selladurai, Experimental analysis of a new refrigerant mixture as drop in replacement for CFC12 and HFC 134a, International Journal of Thermal Sciences 47 (2008), 1490-1495. [15]. M. Fatouh, M Kafary, Assessment of propane/commercial butane mixtures as possible alternatives to R134a in domestic refrigerators, Energy Conservation and Management 47 (2006), 2644-2658. [16]. Chao-Chieh Yu, Tun-Ping Teng, Retrofit assessment of using hydrocarbon refrigerants, Applied Thermal Engineering 66 (2014), 507-518. [17]. S. Dalkilic, S. Wongwises, A performance comparison of Vapor-compression refrigeration system using various alternative refrigerants, International Communications in Heat and Mass Transfer, 37(9),(2010) pp.1340-1349 DOI: 10.9790/1684-1401057582 www.iosrjournals.org 82 Page