AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Similar documents
WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

AFUE 95% Heating Input 50,000 to 200,000 Btuh

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

MERIT SERIES Downflow

ELITE SERIES Downflow - High Efficiency Blower Motor

13 GEP A L P - 1 A

8+* Bulletin No November 1997

SERIES 19A. mith PRESSURIZED WET BASE

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

INSTALLATION INSTRUCTIONS

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

RGE 13 A T - 1 A

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

SECTION HEATING BOILERS

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

High efficiency, cast-iron gas boiler

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

G315/6 Cast Iron Boiler

SERIES II OIL-FIRED CAST IRON HOT WATER BOILER

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

Suggested Specifications Prestige Excellence 110

G315/5 Cast Iron Boiler

G515/7 Cast Iron Boiler

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G615/11 Cast Iron Boiler

Peerless Boilers. Series MI. Residential Gas Boilers

DIVISION FINNED WATER-TUBE WATER HEATERS

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

DIVISION FINNED WATER-TUBE BOILERS

MERIT Series R-410A - Upflow / Horizontal

Product Data BW9 WATER BOILER SERIES B

MERIT SERIES Downflow

FINNED WATER-TUBE POOL HEATERS

MERIT Series R-410A - Upflow / Horizontal

DIVISION FINNED WATER-TUBE BOILERS

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

BC Series II OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR US AND CANADIAN SALES

DIVISION FINNED WATER-TUBE WATER HEATERS

Raypak Residential Products

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

DIVISION FINNED WATER-TUBE BOILERS

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Utica Boilers MAC Submittal

Revitalize Building Mechanical Systems (4619)

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Burner Comparisons. Typical Competitor s Burner

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

FINNED WATER-TUBE POOL HEATERS

Heating system service plans that provide total peace of mind.

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

High Capacity Instantaneous Steam Fired Water Heater

Gas Valve. Combustion Air Intake. Supply Air Blower AM30. Typical Applications

Columbia Boiler Company

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

mith Mills 4500A Smith Mills 4500A 4500A-3R OIL, GAS OR COMBINATION GAS/OIL COMMERCIAL BOILER/BURNER CAST IRON

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

MERIT SERIES Up Flow / Horizontal

A. Product Data: Include rated capacities, furnished specialties and accessories.

Replacement parts EG/PEG

mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Design and Construction Standards SECTION PLUMBING EQUIPMENT

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

83.5 % UP TO 95 % 86.5 % High to Mid-Efficiency Residential & Commercial Heating Solutions. Boilers and Indirect Water Heaters

TriFire High Efficiency Oil Fired Hot Water Boiler

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

DOMESTIC WATER HEATER OIL FIRED

Indiana WX Oil Furnace Inspection Guide

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Date: Project #: Engineer: Prepared By: Bid Date:

DIVISION FINNED WATER-TUBE BOILERS

G34M Bulletin #69/ August 2003

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

TECHNICAL SPECIFICATIONS

BETTER HOME COMFORT AND PEACE OF MIND STARTS WITH THE BEST SERVICE PLANS.

VICTORYVSPH THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY.

SECTION WATER HEATERS

ADF/ADFH 300 and 500

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50

High Efficiency 3-Pass Oil Fired Hot Water Boiler

UTICA BOILER. SSV Submittal. Project Name: Project Location: Contractor:

Transcription:

WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION COWB3-3 Series COWB3 = Oil-Fired Hot Water Boiler Number of Sections FEATURES CONTENTS Circulating Pump Flow Rate...6 Dimensions...5 Features... Installation Clearances...5 Model Number Identification... Optional Accessories...4 Specifications...4 WARRANTY Cast iron boiler assembly - Limited twenty-year warranty in residential applications only. All other covered components - Limited five-year warranty in residential applications. Refer to Lennox Equipment Limited Warranty certificate included with equipment for details.

FEATURES APPROVALS Annual Fuel Utilization Efficiencies are based on US Department of Energy test procedures and Federal Trade Commission labeling regulations. Units are certified by AHRI. Boilers also carry listings and approvals by CSA. Boiler heat exchanger assemblies are constructed and hydrostatically tested in accordance with American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Section IV Standards for cast iron heating boilers. APPLICATIONS Oil-fired hot water boilers are available in six sizes with heating inputs of 05,000 to 45,000 Btuh. AFUE of up to 85.% Boilers may be used in a wide variety of applications including radiant floor heating, baseboard heating and zoned heating systems. Compact size allows easy installation in a basement or utility room. All units are completely factory assembled with all controls installed and wired. HEATING SYSTEM Beckett Oil Burner Smooth operating, high-pressure atomizing type burner blends oil and air for maximum efficiency. Heavy-duty permament split capacitor (PSC) motor drives quiet operating blower wheel and fuel pump. Flame retention head is designed to agitate and mix oil and air for complete combustion and highest efficiency. Burner has 0,000 volt ignition transformer and ceramic glazed electrodes which provide a safe, continuous flame. Equipped with a factory installed cadmium sulfide cell flame detector and primary safety control that provides complete shutdown in case of flame failure. Interrupted-duty primary control features 5 second prepurge and limited recycle and limited reset controls. All burner parts are easily removed for servicing. Burner is certified according to ANSI Standard 96.6. Burner is factory installed in the unit, wired and tested. Burner is shipped with nozzles for dual input/output firing rate. See Specifications tables for ratings. Field installation of nozzle is required. Burner mounted swing door allows complete access to combustion chamber and burner end cone for set-up, maintenance and cleaning. Eliminates complete burner removal. Solenoid delay oil valve ensures positive fuel shut-off and eliminates after-drip. Also provides improved burner operation, cleaner combustion and quiet operation. Cast Iron Boiler Assembly Boiler sections and push nipples are constructed of long life cast iron. Boiler sections and push nipples expand and contract together, providing positive watertight seal. Thermal pin design increases heat transfer efficiency. Wet base design allows water circulation over complete heat exchanger surface for maximum heat transfer. Boiler components are easily accessible for cleaning and servicing. Target wall of combustion chamber is constructed of vacuum formed refractory ceramic fiber allowing maximum high temperatures for more complete combustion and higher efficiencies. Peephole in the cast iron burner swing door allows flame inspection. Jacket attaches directly to cast iron heat exchanger for increased stability when handling product. Water Circulating Pump (Not Furnished in Canada) Heavy duty pump is constructed of cast iron. Bronze isolation ball type valves on inlet and outlet of pump eliminate need to drain system if pump servicing is required. Pump motor is impedance protected. Motor and impeller is removeable as a single unit for servicing. Pump is shipped wired to boiler ready for field installation in a supply side pumping mode. Relief Valve Furnished as standard for field installation in rear of cabinet. Valve provides for pressure relief of heating system in case of abnormal operating conditions. Valve opens at 30 psig and is approved by ASME. Brass Drain Valve 3/4 in. brass drain valve is furnished for field installation in drain outlet on front of cabinet. See dimension drawing for location. COWB3 / Page

FEATURES HEATING SYSTEM (continued) Optional Accessories Tankless Hot Water Coil Tankless water heater coil supplies a moderate amount of instantaneous hot water for kitchen, bath and laundry usage. Limit control is factory wired for field installation on tankless coil control well to maximize hot water heating performance for instantaneous heating. Raised coil port extends through jacket to allow easy servicing and inspection of tankless coil without removing panels. Water line connections are furnished on side of boiler cabinet. See dimension drawing. VENTING Barometric Draft Control Furnished as standard equipment for field installation in flue pipe. Flue Brush Furnished with unit for cleaning flue passageways. CONTROLS High Limit and Circulator Relay Control Factory installed, immersion type limit control gives protection against abnormal operating conditions. Control monitors water temperature and delays burner start-up until any residual heat has been utilized first. Thermal purge logic measures rate of temperature change inside the boiler and delays burner firing accordingly. Maximizes efficiency by operating burner only when needed. Operation with optional Tankless Hot Water Coil - Low Limit Control seeks maximum temperature to satisfy domestic hot water call bypassing thermal purge logic. Limit control is adjustable from 40 F to 40 F. Circulator relay operates pump during thermostat demand. Display LEDs - Three, seven segment LEDs display alpha-numeric information related to diagnostics as well as system operation and status. Diagnostic codes are held in non-volatile memory, immune from power interruptions.factory installed on front of cabinet. Combination Temperature/Pressure Gauge Located on top of unit cabinet. Monitors system for safe and reliable operation. Optional Accessories Thermostat See Thermostat bulletins in Controls section and Lennox Price Book for a complete list of thermostats. CABINET Constructed of heavy gauge steel with a baked-on enamel paint finish. Cabinet is fully insulated with fiberglass insulation, keeping cabinet surface temperatures low. Controls are shipped factory installed on cabinet. Top and front cabinet access allows easy cleaning and servicing of unit. COWB3 / Page 3

SPECIFICATIONS Oil Heating Performance Model No. COWB3-3 COWB3-4 COWB3-5 Input - Btuh Low Fire Nozzle 05,000 75,000 45,000 High Fire Nozzle 40,000 0,000 - - - Output - Btuh Low Fire Nozzle 9,000 5,000 0,000 High Fire Nozzle 0,000 79,000 - - - Net AHRI I=B=R rating - Btuh Low Fire Nozzle 80,000 3,000 83,000 High Fire Nozzle 04,000 56,000 - - - 3 AFUE Low Fire Nozzle 85.% 85.0% 84.3% High Fire Nozzle 84.0% 84.0% - - - Boiler Number of boiler sections 3 4 5 4 Nozzle Ratings Net boiler heating surface - sq. ft. 8.54 5.6 3.78 Boiler capacity - U.S. gallons 9.6.6 3.7 U.S. gallons/min. Low Fire Nozzle 0.75.5.75 High Fire Nozzle.00.50 - - - Oil Burner Pump Factory setting 00 psi stage stage stage Connections in. Oil piping size N.P.T. /4 /4 /4 Flue size diameter 6 6 6 Water supply size N.P.T. -/4 -/4 -/4 Water return size N.P.T. -/4 -/4 -/4 Drain connection size N.P.T. 3/4 3/4 3/4 Shipping Data - lbs. ( package) 49 575 673 Electrical characteristics OPTIONAL ACCESSORIES See Lennox Price Book For Complete Listing of Optional Accessories 5 Tankless Water Heater NOTE - Circulating pump is not furnished in Canada and must be field supplied. 0 volts - 60 hertz - phase (less than amps) Catalog Number 7M0 7M0 7M0 U.S. gallons/min. Low Fire Nozzle 3.00 3.50 4.00 Heating capacity based on 3% CO with 0.0 in. w.g. draft over fire and # smoke or less. High Fire Nozzle 3.5 3.75 4.5 Net AHRI ratings indicate the amount of equivalent direct radiation each boiler will produce under normal conditions and thermostatic control. Ratings based on an allowance of.5 in accordance with the factors shown on the I=B=R Standard as published by The Hydronics Institute. Selection of boiler size should be based on Net I=B=R Rating being equal to or greater than the calculated heat loss of the building. 3 Annual Fuel Utilization Efficiency based on U.S. DOE test procedures and FTC labeling regulations. 4 Based on 40,000 Btuh per gallon. 5 Water heated from 40 F to 40 F with 00 F boiler water temperature, intermittent draw. COWB3 / Page 4

DIMENSIONS - INCHES (MM) 0-/ (5) TEMP./ PRESSURE GAUGE 3-3/4 (349) A B 6 (5) LIMIT CONTROL WATER OUTLET INLET OUTLET OPTIONAL TANKLESS COIL WATER HEATER CONNECTIONS RELIEF VALVE OUTLET 36 (94) WATER RETURN FRONT VIEW OIL BURNER DRAIN VALVE (Furnished) RIGHT SIDE VIEW BACK VIEW Model No. A B in. mm in. mm COWB3-3 4-/ 368 8 03 COWB3-4 7-3/4 45 9-5/8 44 COWB3-5 533 -/ 9 INSTALLATION CLEARANCES Side Side with optional tankless coil Rear Top Top (Service) Front Front (Service) 6 inches (5 mm) 8 inches (457 mm) 6 inches (5 mm) 6 inches (5 mm) 8 inches (457 mm) 8 inches (457 mm) 4 inches (60 mm) Floor *Non-Combustible Flue Pipe to Combustible 8 inches (457 mm) NOTE - If boiler is installed in a confined space, two ventilation openings must be provided into the space; one at least inches (305 mm) from the top and one at least inches (305 mm) from the bottom. Each opening should have a minimum free area of in. (645 mm) per 000 Btu per hour (0.93 kw per hour) (inside air) of the total input rating of all equipment in confined area. For applications with outside air, each opening should have a minimum free area of in. (645 mm) per 4000 Btu per hour (.7 kw per hour) for vertical ducts and 000 Btu per hour (0.59 kw per hour) for horizontal ducts to the outside. NOTE - In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA 54/ANSI-Z3.) or applicable provisions of local building codes. In Canada flue sizing must conform to the methods outlined in National Standard of Canada CAN/CSA-B49.. Clearance for installation on combustible floor if combustible flooring base (field supplied) is installed between the boiler and the combustible floor. COWB3 / Page 5

CIRCULATING PUMP FLOW RATE TOTAL HEAD-FEET 0.0 0.3 0.6 0.9..5.8..4.7 3.0 3.3 3.6 3.9 4. 4.5 4.8 5. 5.4 6 4.8 003B 4 005 4. 3 006 4 006B * 5 007 3.6 6 008 0 8 6 5 4 3 6 00 CIRCULATORS FLOW-M3/H 3.0.4.8 TOTAL HEAD-METERS 4. 0.6 0 0.0 0 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 3 4 FLOW-GPM *007 Pump furnished with all boilers. COWB3 / Page 6

REVISIONS Section New Description Added circulator pump flow rate chart. C US Visit us at www.lennox.com For the latest technical information, www.lennoxpros.com Contact us at -800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 08 Lennox Industries, Inc.