AED Alarm System Model Operations Manual

Similar documents
Exit Stopper. STI-6400 Series

Addendum for STI-6406 with Dual Access Control

Exit Stopper. STI-6400 Series

MD12-1 Vehicle Loop Detector

HOME SECURITY MICROPROCESSOR CENTRAL UNIT HOME 5 USER S MANUAL

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

Wireless D.I.Y. Alarm Kit

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

Protective Cabinet STI-7534, STI-7535 and STI-7535AED

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

SA3. 6 Zone Wirefree Alarm System. Installation & Operating Manual 0 # ESC ENTER ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)


D7053. Installation Instructions Multiplex Input/Output Module

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

OWNER'S MANUAL T0140. Contents Page #

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

2-ZONE EASYFIT INTRUDER ALARM

Sentry 4 Zone Alarm Panel User Manual

IDM4 CARAVAN ALARM. Operating instructions

INSTRUCTION MANUAL C-4010 SCAN HERE

Installation and Operation Guide EXTERNAL SIREN

2-ZONE EASYFIT INTRUDER ALARM

ELECTRONIC SOUNDER STROBE Model : AVD-C407

V-MUL-033(A0) RADIOLINK BASE

What to Expect with Your Installation. Tools Needed. 30 inches PA G E. To register your fan, please visit: 11 PA G E

MULTIGUARD MULTIGUARD USERS MANUAL TYPE S3/240W 26/01/2010

Installation Instructions

SMARTWALK DEMENTIA WANDERING SYSTEM

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

Owner s Manual. Digital Thermostat

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

This document applies for optional accessories for the DSP70-C1 kit To read attentively and to conserve for further consultation

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

WIRING DIAGRAM AND INSTRUCTIONS

ALARM OUTPUT MODULE. Product #7736

Premier Hazard STC Instructions

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

Installation & Operations Manual

CAR BURGLAR ALARM K3504

Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

Wireless Alarm system s manual

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

DS160/161 Request To Exit PIR sensors Installation Instructions

Please read and save these instructions. Should you have any questions or difficulty installing your fan, call us first!

ED4000 & ED5000 SERIES EXIT DEVICES with M61 ALARM OPTION and ED40AK & ED50AK ALARM RETROFIT KIT

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

Voice Dialer. Manual E-921CPQ E-921KPQ

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

SA3. 6 Zone Wirefree Alarm System. Installation & Operating Manual ESC ENTER ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 FIRE TAMPER

SERVICE MANUAL REFRIGERATION

Ceiling Fan Installation Instructions

QA16 Addressable System

Operating Guide. English Version 3.3

Wall Mounted Mini Split Heat Pump Air Conditioner

2000 Series Sensors Installation Guide

All-In-One Wireless Security System V1.0. Model #: MG-6060

Single Station Remote Alarm

Independent Zone Control (I.Z.C.)

CONTENTS. 1 INTRODUCTION 2 Planning the installation 2 Nexus 8 installation example 3

Ceiling Fan Installation Instructions

3DIR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3DIR52XXD

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

INSTRUCTION MANUAL WT 498S Radio Controlled Alarm Clock with Temperature and Calendar

CONTROL DEVICE SLIDETRONIC HD

Interface and EOL Modules 8

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

Auto Dialer. Manual E-921APQ E-921GPQ

GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150. User Manual

SECURITY FOG GENERATOR MANUAL MODEL NO. : GS903

other ambient light sources. Before installation, make sure to read this instruction manual carefully for safe and effective product operation.

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Isco 3700ZR Sampler. Manual Set

Your Pope Simple Set Automatic Tap Timer

THE GUARDIAN III OWNER S MANUAL. Stops Rangetop Fires Instantly. For Installation, Operation and Maintenance

INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL FOR. Remote Control Car Alarm with Impact Sensor, Mini-Battery Backup Siren & Engine Immobiliser

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

3VNR52/42XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3VNR52XXD / 3VNR42XXD

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

D7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector

Your GardenMate Easy Dial Automatic Tap Timer

Conventional Fire Alarm System 2014 V1.2

JA-63 PROFI Alarm System MGK55402

6 Assembling the Blades

United Kingdom. Smart Thermostat 230 V Relay Installations. Guide for Professional Installers

FEC400 Series. Installation Manual

CHEAT SHEET: SPECTRA V2.1

Long-Range Barrier Sensors

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

5AZR56XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5AZR56XX

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

Ceiling Fan Installation Instructions

Installation and ZONES: Operation Manual. Model: ON STI-34108

Protocol Station Remote Alarm

Transcription:

AED Alarm System Model 200900 Operations Manual Printed In the USA 2005

Table of Content Section 1 o Features Alarm volume Alarm settings Mechanical door switch External alarm connection Low battery chirp Section 2 o Standard Features Key Switch Mechanical switch External Alarm Relay Wiring Choice of alarm activation options Section 3 o Optional Accessories Strobe Reed switch Section 4 o Alarm activation settings 1. Alarm activates when door is opened, shuts off when door is closed. 2. Alarm activates when door is opened, shuts off with key only. 3. Activates for 30 seconds when door is opened. 4. Activates for 3 minutes when door is opened. Section 5 o Battery Standby Full operation Changing Battery Section 6 o Trouble Shooting Guide -1- Section 6 MMP MODEL 200900 ALARM SYSTEM TROUBLE SHOOTING GUIDE 1) KEYED SWITCH IS IN THE ( ON ) POSITION 2) ALARM SWITCH ON FRONT OF ALARM IS SWITCHED TO THE (ALARM) POSITION. SEE PICTURE ON FRONT COVER. 3) OPTION SWITCH 1 IS IN THE (DOWN) POSITION AND 2, 3, AND 4 ARE IN (UP) POSITION. PG. 7, SECTION 4, OPTION 1. 4) CHECK JACK PLUGS ARE PUSHED IN AND SECURE. PG. 4, FIGURE 2-1. 5) CHECK CONNECTION ON STROBE (IF SO FITTED ) THAT IT IS PUSHED IN AND SECURE. PG. 6 SECTION 3, FIGURE 3-1. AT THIS POINT THE ALARM SHOULD SOUND WHEN DOOR IS OPENED AND SHUT OFF WHEN DOOR IS CLOSED. IF THE ALARM SOUNDS AS SOON AS THE KEYED SWITCH IS TURNED TO THE (ON) POSITION WITH THE DOOR CLOSED. FIRST CHECK #3 FROM ABOVE LIST. ALSO CHECK TO SEE THAT THE RUBBER BUMPER IS MAKING CONTACT WITH THE MECH. SWITCH. (THE RUBBER BUMPER IS LOCATED ON THE INSIDE OF THE DOOR AND SHOULD BE CENTERED IN THE RECTANGLE WERE MECH. SWITCH MEETS THE DOOR IN THE CLOSED POSITION. ) IF THE ALARM DOES NOT SOUND WHEN DOOR IS OPENED. CHECK ITEMS 1-5 IN THE ABOVE LIST AND ALSO TRY A NEW BATTERY. IF THESE INSTRUCTIONS DO NOT GET THE ALARM OPERATING, PLEASE CONTACT YOUR DISTRIBUTOR. -10-

Battery Section 5 Features Section 1 o Standby The battery life of the alarm is determined by the state of the alarm. When the alarm is in standby, the buzzer and strobe off, the alarm will function in standby for two full years with out needing a battery change. It is still recommended to change battery twice a year o Full operation When the unit is activated and the strobe and buzzer are functioning, the unit will function for a full two hours. Note: The battery should be changed every time the unit is activated to ensure full life expectance. o Changing the Battery The battery can be changed while the unit is still mounted, or after the unit has been removed. In either case the battery is accessed from the front of the unit by removing the two Phillips head screws and lifting the battery cover off as shown in Figure 5-1 o Alarm volume The alarm has a very high decibel level (85-120 db). The decibel level will vary with the life of the battery. See section 5 for more information on battery life and when to change. o Alarm setting Alarm has the option to be activated in four different settings. See Section 4 for more details on how to set alarm. 1. Alarm activated when door is opened, shuts off when door is closed. 2. Alarm activated when door is opened, shut off with key only. 3. Activates for 30 seconds, when door is opened. 4. Activates for 3 minutes, when door is opened. o External alarm relay wiring The optional relay wiring is used to connect the alarm to an external security monitoring system. See section 2 for more details. Remove screw Remove screw o Mechanical door switch The mechanical door switch is used to activate the unit when the door is opened and deactivate the unit when the door is closed. See section 2 for more details. Figure 5-1 Note: The battery is to be replaced with an industrial 9v Alkaline battery. -9 - o Low battery chirp Alarm has a low battery chirp to warn when battery is low. When chirp is heard change the battery as soon as possible. See section 5 for battery details and instructions. - 2 -

Section 2 Standard Features o Key Switch The Key Switch is attached to the right side of the unit as indicated in Figure 2-1. 3. Alarm activates for 30sec after door is opened. To obtain this setting Dip switches 1, 2 and 3 will need to be in the down position while switch 4 is up, see Figure 4-3. Key Switch Down Figure 4-3 Strobe 4. Alarm activates for 3 minutes after door is opened To obtain this setting Dip switches 1, 2, and 4 will need to be in the down position and switch 3 in the up position, see Figure 4-4. Figure 2-1 Note: If the Key Switch is attached and turned on, without any of the switches attached, the unit will be armed and activate. The unit requires a switch to be deactivated when armed. Down UP -3 - Figure 4-4 -8-

Section 4 1. Alarm is activated when door is opened, shuts off when door is closed. To obtain setting #1 Dip switch 1 will need to be down and the rest up, see in Figure 4-1 Down Section 2 o Mechanical door switch The mechanical door switch is used to activate the alarm when the door is opened, deactivate the unit when the door is closed. Mechanical door switch is attached to the cabinet and connects to the left side of alarm. See Figure 2-1 Figure 4-1 2. Door is open unit is activated until reset/turned off with the key switch Setting #2 can be accomplished by putting all of the DIP switches in the up position see in Figure 4-2 Figure 2-1 Not shown to scale Figure 4-2 -7- -4-

Section 2 o External alarm relay wiring The relay wiring is used for connecting the alarm to an external security system. Wires are connected by inserting them into the upper slots of the connector as seen in figure 2-2. They can be removed by pressing a small flat blade screwdriver into the bottom slot that corresponds with the wire needing to be removed see figure 2-2. Section 3 Optional accessories o Strobe The strobe is used as a visual indication of the alarm being activated. The strobe is powered by the alarm and only requires to be connection to the right side of the alarm see figure 3-1. When the alarm is in the off position the strobe will still activate when the door is open. The strobe can be purchased at the same time as the alarm or added after. Insert Wire Here N/C N/O Strobe COM Press Here Figure 2-2 Figure 3-1 Reed switch The reed switch is used in place of the mechanical switch. It activates the alarm when the magnetic field is broken. This option is available at an additional cost. -5- -6-