COMPANY OVERVIEW Company Overview Commencing operations in 1999, Incite Fire has quickly become a leading supplier quality fire detection products and

Similar documents
Certificate of Conformity Certificate num. Registration date Version Valid until Number Issue date

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Solution F2. Fire Alarm Control Panels one step ahead.

Electronics Ltd. Life Safety System Specialists

The EN54 Part 2 & 4 Fire System

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Wireless Fire & Security Solutions. Fire Product Showcase

ZXSe Range Data Sheet

The EN54 Part 2, 4 and 13 Fire System

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Advanced FireAlarm Panel 1-4Loop

DCS-100. intelligent damper control & monitoring system

Vigilant MX4428 Fire Alarm System

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Different types of Fire Alarm System

Touch Screen 1 loop Addressable Fire Alarm Panel

Solution F1. Fire Control Panels the new generation

SUPREMATouch. Modular Fire & Gas Detection System

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

SUPREMATouch. Modular Fire & Gas Detection System

Addressable and Conventional Fire Protection

An introduction to... Sigma

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

ID2000. intelligent fire alarm panel

Intelligent Security & Fire Ltd

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

World Class Leaders in Fire Detection Since PRODUCTCATALOGUE Fire Detection Solutions

Hochiki Devices. It also highlights any specific requirements and technical information.

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

INTELLIGENT FIRE ALARM CONTROL PANEL

Fire and Smoke Control Systems

Syncro AS. Analogue Addressable Fire Control Panel. Product Manual

MINERVA MZX125 Digital Addressable Fire Detection System

IGD.CO.UK

Fire control panels FC726 FC726-XA

The Kentec driver connects to the Kentec Syncro range of fire detection panels. Available for Commander and ObSys.

The supplier and installer of the system should be approved by the local civil defence authority.

ID3000 intelligent. fire alarm panel

ID3000 intelligent. fire alarm panel

APPLICATION NOTE. Document Type. Application Note. Document Title. Date January Version DS0167/Iss 2. ESP Technical Summary

Addressable Fire Alarm Control Panel

HART XL High Sensitivity Smoke Detection

CODESEC FIRE ALARM SYSTEMS. security technologies

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

ID50series. intelligent fire alarm panels

Intelligent Security & Fire Ltd

Consultant Specification AGILE Wireless Fire Detection System

EMERGENCY LIGHTING SYSTEM

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

A Guide To BS Understanding the selection, spacing and siting of detectors

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Fire Detection - Addressable

2004 AUSTRALIAN STANDARDS UPDATE

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

Wireless Fire & Security Solutions. Fire Product Showcase

ACP10 & ACP50 Security Systems

Evolution Analogue Addressable Fire System

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

Integrated Security Solutions

Intelligent addressable fire alarm control panel

On the job around the clock 24/7: Fire detection systems

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

Flopurge TS. Operation Manual

Reliably Advanced Extinguishing Control

Saxon Range 1-8 Zone Convertional Control Panels

System 800 Addressable Fire Detection & Alarm System

VIGILANT MX1-Au Fire detection and alarm system Engineer s Specification

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

TrueAlarm Fire Alarm Controls

Flostop TS D7E and A8E. Operation Manual

Conventional Fire Detection

Emergi-Lite Orbis detectors

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

Fire detection and alarm

Fire control panel detect 3004 plus and accessories

Intelligent Addressable Fire Alarm System

Precept Marine Control Panel Application Guide

Fire Signalling. Signalling Solutions

MINERVA MZX125. Digital Addressable Fire Detection System

IQ8Control C Fire Alarm Panel

Intelligent Security & Fire Ltd

SYSTEM 3400 ANALOGUE ADDRESSABLE FIRE DETECTION. (with Devices) Operating Manual Version 3.3X Issue 2 September 1996

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Transcription:

FIRE DETECTION AND WARNING EQUIPMENT 1300 INCITE www.incitefire.com.au Version 6.0 2018

COMPANY OVERVIEW Company Overview Commencing operations in 1999, Incite Fire has quickly become a leading supplier quality fire detection products and ancillaries. Incite Fire supplies Hochiki fire panels and detectors, gas panels and detectors, fire extinguishing and mimic panels, Securiton aspirated smoke detection, QE90 emergency warning evacuation systems and a range of ancillaries including door holders, sounders, BOSCH speakers, STI call points and guards, Potter sprinkler monitors, extinguishers and fire blankets as well as specialised HFT and Greenstar conduits. Sydney Panel Assembly / Customisation Operation Incite Fire have offices in Sydney, Melbourne, Brisbane and distributors in South Australia and Western Australia. Incite Fire also have a manufacturing/assembly factory located in Sydney. Incite Fire Sydney Office Products Conventional Incite Fire stock complete range of Hochiki detectors, as well as a selection of conventional panels which can be customised to suit your requirements. Analogue Incite Fire is national distributor of Kentec (Hochiki) fire panels, Hochiki addressable detectors and field modules. SECURITON Incite Fire are pleased to announce y are now distributing Securiton range of ASD products throughout Australia. Aspirating smoke detectors from Securiton provide precise and reliable early warning detection systems against fires. Securiton have a complete range of models that quickly identify presence of smoke. These cover a wide range of applications and are cost effective. Warning Systems Incite Fire supplies OWS warning systems and accessories to suit your requirements, as well as EWIS panels to suit any site specifications. Ancillaries Incite Fire have a comprehensive range of ancillary devices including KAC manual call points, a selection of speakers, sounders and strobes. We also stock a range of magnetic door holders to suit many different applications including new brass and chrome finish door holders more prestigious application. Special Application A selection of detection equipment special applications including Spectrex flame detectors, and firewire. Also available is intrinsically safe equipment and detectors suitable marine applications. Miscellaneous For convenience we also stock a selection of tools, fixings, enclosures & cable. For furr inmation Call: 1300 INCITE (462483) Or visit us at: www.incitefire.com.au 2

CONTENTS ANALOGUE WIRELESS CONVENTIONAL ANCILLARIES WARNING SYSTEMS ASPIRATING SYSTEM SPECIAL APPLICATIONS EMERGENCY LIGHTING SELECTRO CHARTS Taktis systems 4-7 Syncro systems 8 Syncro selector 9 Syncro system diagram 10-11 Syncro add ons and options 12-16 Syncro and Taktis detectors and devices 17-25 Firenet system, detectors and devices 26-31 Wireless detectors and devices 32-35 Conventional system 36-37 Conventional add ons and options 38-39 Conventional detectors and devices 40-46 Extinguishant systems 47 Signs, warning signs and labels 48 Keys 49 Manual call points 50-51 Protective products 52-53 Magnetic door holders, remote indicators and power supplies 54 Testing equipment 55-56 EWIS panels, tone generators and amplifiers 57 Speakers and horns 58-59 Sounders and strobes 60-61 Securiton detectors, sensors, modules, software, accessories 62-67 Pipe, fittings and Blazer 68 Marine panels and detectors 69-72 Intrinsically safe detectors 73-75 Stat X, rmal probes and heat wire 76 Flame detectors and Firebeam 77-79 Exit Signs, emergency lighting, batteries, accessories 80-89 Detector selector charts 90-93 Catalogue Disclaimer 1.1 The inmation contained in this catalogue is obtained from various manufacturers of products. We are merely passing inmation to you. We do not guarantee that inmation is correct. Prior to making a decision to purchase you should confirm details of product with an alternative source directly. 1.2 Product descriptions and specifications are subject to change at any time, without notice. 1.3 We do not guarantee that any particular product will be available sale. The availability sale of products described in this catalogue depends on manufacturer and is beyond our control. This catalogue is not an offer of sale. 3

TAKTIS ANALOGUE PANELS Taktis Analogue Addressable 2-16 Loop Control Panels TAKTIS-S1 TAKTIS FIRE PANEL (H) 585 x (W) 420 x (D) 167 TAKTIS-S2 TAKTIS FIRE PANEL (H) 710 x (W) 500 x (D) 167 TAKTIS-S3 TAKTIS FIRE PANEL (H) 1065 x (W) 560 x (D) 239 The Taktis product range combines very latest hardware and software to produce a control and indication system, which is powerful and sophisticated, yet simple to use and understand. The large graphical touch screen provides a clear, uncluttered and intuitive interface so end user requires minimal training. Available in 4 slot and 8 slot variants, with each slot supporting a 2 loop detection card, Taktis fire control panel ranges from 2 to 16 detection loops. The generous quantity of sounder circuits, relays and inputs provided as standard can be furr increased by addition of one or more Taktis I/O plug in expansion cards. The Taktis Network Card allows networking of up to 128 panels and repeaters meaning that Taktis can provide reassurance to all building owners/ operators wher responsible a small system or a large complex. Taktis Vision panels can be connected to Taktis network to provide a fully functional repeater in a compact enclosure. 2 to 8 loop or 2 to 16 loop versions 500 milliamp loop current 4 programmable sounder circuits each rated at 2.5 Amps 5.25 Amp or 10.25 Amp power supply options 3 programmable inputs 5 programmable relay outputs Up to 512 programmable I/O via optional plug in and serially connected expansion cards Hard wired fire and fault routing inputs and outputs Modular electronics Over 4000 sub address points per panel COINCIDENCE, OR and AND operators in cause and effects Option to invert inputs and outputs Powerful, standard configuration templates Network up to 128 panels Configurable via USB port to PC or memory stick The remote management features offered by Virtual Resource can result in reduced fault calls, improved technical support, efficient and proven maintenance, reduction of unwanted alarms, a full audit trail and improved overall service to end user. 4 AFP : 2968

TAKTIS ANALOGUE PANELS TAKTIS-VISION-N Taktis touch screen repeater Robust, full colour, 7 800 x 480 touch screen graphical display The large, full colour graphical display with touch screen functionality, delivers inmation on status of fire alarm system to single or multiple locations. Full indication of all inmation displayed at fire control panel Configurable Fire Alarm Repeater 24V DC Taktis Vision repeaters can be configured to offer full display and control to replicate functionality of fire control panel or to operate as a simple, display only device applications where access to control fire alarm system would be inappropriate. Automatic display brightness adjustment Silenceable internal buzzer Connections Via: Control panel RS485 bus Option to connect to control panel network Low current, 24V DC powered TAKTIS-KAU2044 Taktis Fan Controller (Master Module) Select your ASE Bracket TAKTIS-KAU2060 Taktis Fan Controller (Slave Module) EVAC-SD-FACIA TAKTIS OWS Control TAKTIS-KAU2045 Taktis Ancillary Module TAKTIS-SECRDU SECURITON Control Display TAKTIS-KAU2046 Taktis LED Module TAKTIS-BBS1 Battery Box (H) 230 x (W) 420 x (D) 167 TAKTIS-BBS3 Battery Box (H) 395 x (W) 560 x (D) 239 TAKTIS-K772 16 Channel I/O Board TAKTIS-K792 8 Way Conventional Zone Board TAKTIS-K791 8 Way Relay Board TAKTIS-K793 4 Way Sounder Board 5

TAKTIS ANALOGUE PANELS HOCHIKI SYSTEM (2-16 LOOP TAKTIS PANEL) HIGH INTEGRITY CONFIGURABLE NETWORK TAKTIS 2-8 Loop Analogue Addressable Control Panel (if fitted) LOOP 1 LOOP 2 Each loop is capable of hosting up to: 127 devices, plus 127 Sounder Bases LOOP 3 - LOOP 8 Control Panel is manufactured by Hochiki Group Company, Kentec Electronics Ltd. and distributed by Incite Fire Pty Ltd. TAKTIS DISPLAY Taktis utilises a full colour, 7 800x480 touch screen graphical display to provide a clear, simple and intuitive user interface. 80 character zone location and 80 character device messages allow a clear, concise description of each detection device location to be configured. COMING SOON TAKTIS VIRTUAL RESOURCE VR VAULT TAKTIS DISPLAY - FUNCTION BUTTONS Up to 24 customer specific function buttons may be configured to provide control, disablement and engineering functions. TAKTIS VISION VR ACCESS - Access data from all your systems - Secure document vault Configurable Fire Alarm Repeater 24 Vdc The functions buttons can be configured to be eir available or hidden each log in profile. VR SERVICE - Complete service management utility with automated data transfer VR PRINT Media Gateway - Eliminates need panel mounted printers COMING SOON Cloud Servers GSM IP Dial-Up TAKTIS 2 16 Loop Analogue Addressable Control Panel 6

TAKTIS ANALOGUE PANELS TAKTIS 2 8 Loop Analogue Addressable Control Panel (if fitted) LOOP 3 -LOOP 16 LOOP 2 Each loop is capable of hosting up to: 127 detectors, plus 127 Sounder Bases LOOP 1 USER ACCESS Access to Taktis menu and control functions is provided by a unique 6 digit pass code or by optional enable control key switch. Up to 64 individual login accounts can be configured, with different profiles and access permissions. EVENT LOG A 10,000 entry event log records all system activity to 1 second resolution. The log is held in secure memory and is retained when power is removed from Taktis. Powerful filtering allows log to be sorted by event type, between dates, by zone, by panel and by address. Using Loop Explorer 2 configuration program, event log can be downloaded and stored as a comma separated values (csv) mat. Up to 128 Panels/Repeaters can be added to network 1/0 Cards Plug in slots TAKTIS-K772 TAKTIS-K791 TAKTIS-K792 TAKTIS-K793 16 Channel I/O Board 8 Way Relay Board 8 Way Conventional Zone Board 4 Way Sounder Board COMING SOON RS485 bus TAKTIS VISION Configurable Fire Alarm Repeater 24 Vdc TAKTIS 2 16 Loop Analogue Addressable Control Panel 7

SYNCRO AS 1-2 LOOP SYSTEMS Syncro AS Key Features Analogue Addressable Fire Control Panels (1 or 2 Loops) 1. Accomodation mode: Accomodation mode is an automatic function that provides a local warning to occupants and allows a time frame to clear smoke from detector. This function helps prevent false alarms, fire brigade call outs and ir associated costs. 2. Conventional detector connectivity. 3. Seamless wireless connectivity, including detectors, sounders, inputs and outputs 4. LED mimics,diagramatic mimics and LCDs: Up to 32 devices (Including Syncro View,Ident and Matrix) can be fitted to each panel on RS485 serial interface. 5. Networking: Up to 64 panels can be addded to a network 6. Building Management Interface: Syncro allows a BMS interface so you can initiate a BMS solution. ActivFire listed AFP-2761 The Syncro AS addressable control panel is designed to meet requirements of AS7240.2, AS7240.4 Approved to AS7240.2 and AS7240.4 Available in 1 or 2 loops and networkable up to 64 panels with up to 500 zones per network ( perfect solution small and large solutions) 127 devices per loop / Up to 800 sub addresses LCD display & 16 zone LED indication AFP : 2761 Compatible with Hochiki ESP detectors and modules Open protocol, non-proprietary software System enabled with 003 key Optional OWS available - 20,40,60,120 Optional fan control available Capable of driving a high number of loop powered sounders Base cabinet size 385W x 520H x 110D (mm) Range of cabinet sizes available Or Features Standard or deep cabinet options 16 zonal LED indicators 5 preconfigured digital inputs Easily configured using Loop Explorer software Up to 32 RS485 expansion modules per panel 8 Available in 1 or 2 loops and networkable up to 64 panels with up to 500 zones per network ( perfect solution small and large projects) The Syncro AS is capable of driving a full loop of 127 sounders @ 85dB Housed in same installer friendly and attractively styled enclosure as Sigma CP (conventional) and Sigma XT (extinguishant) range of control panels, Syncro AS combines compact and practical styling with programming power and connectivity normally associated with much larger systems Config Features Comprehensive day/night mode facility Programmable one touch test mode Powerful and versatile cause & effect programming Cause and effect wizard including: Cause and effect action Disablement configuration Test mode configuration New Features Accomodation Mode AAF Non latching detectors Non fire attributes: Detector options system control only

SYNCRO SELECTOR Build Your Own Syncro 1 or 2 Loop Panel SYNCRO-Cabinet Size + Loop + Option = Syncro Ordering Code (see below example) SYNCRO-M32C which is an M3 cabinet,2 loop panel with ASE Romtec Cabinet Size Loop M2 (1) 1 Loop (2) 2 Loop (3) 1 Loop Network (4) 2 Loop Network Includes: - Tamper door - MCP - 3Amp P/S Cabinet Size Loops Options M3 (1) 1 Loop (2) 2 Loop (3) 1 Loop Network (4) 2 Loop Network (A) Blank (B) 20 Watt OWS and Controls (C) ASE Romtec (D) ASE Romtec, 20 Watt OWS & Controls (E) ASE Tyco Cabinet Size Loops Options D3 (1) 1 Loop (2) 2 Loop (3) 1 Loop Network (4) 2 Loop Network (A) Blank (B) 20 Watt OWS and Controls (C) ASE Romtec (D) ASE Romtec, 20 Watt OWS & controls (E) ASE Tyco (F) 60 Watt OWS & controls (G) ASE Romtec, 60 Watt OWS & controls Cabinet Size Loops Options D4 (1) 1 Loop (2) 2 Loop (3) 1 Loop Network (4) 2 Loop Network (A) Blank (B) 20 Watt OWS and Controls (C) ASE Romtec (D) ASE Romtec, 20 Watt OWS & controls (E) ASE Tyco (F) 60 watt OWS & controls (G) ASE Romtec, 60 Watt OWS & controls (H) ASE Tyco, 20 Watt OWS & controls (I) ASE Tyco, 60 Watt OWS & controls Includes: - Tamper door - MCP - 3Amp P/S Includes: - Tamper door - MCP - 5Amp P/S Includes: - Tamper door - MCP - 5Amp P/S Customised SYNCRO Panel Options available on request : Fan Controls ANC Controls Relay Cards Or Cabinet Sizes 9

SYNCRO AS 1-2 LOOP SYSTEMS High Integrity Configurable Network 1. Hotel Mode: This function helps prevent false alarms, fire brigade call outs and ir asscoiated costs. LOOP 2 LOOP 1 Accomodation Mode: is an automatic function that provides a local warning to occupants and allows a time frame to clear smoke from detector. (if fitted) 1. Accomodation Mode: SYNCRO AS Network card required 1-2 Loop Analogue Addressable Control Panel (1) ACCOMODATION MODE Speakers EVAC-SD-OWC 6. Building Management Systems Solutions Occupant Warning Control Syncro allows a BMS interface so you can initiate a BMS solution EVAC-SD-20,40,60 Evacuation Module BMS Network card required SYNCRO AS 1-2 Loop Analogue Addressable Control Panel 10

SYNCRO AS 1-2 LOOP SYSTEMS 2 & 3. Wireless and Conventional connectivity 2. Seamless Firewave wireless solution. Including detection, sounders, inputs and outputs (3) 3. Abiltiy to link conventional detectors LOOP 1 (if fitted) LOOP 2 SYNCRO AS Network card required SYNCRO MATRIX Fire Alarm Mimic Display System 24V DC or 230V AC 1-2 Loop Analogue Addressable Control Panel SYNCRO INDENT Programmed LED Indication Panels (2) 24V DC or 230V AC Wireless Solution ANALOGUE SENSORS AND DEVICES 4. Graphics, mimics and repeaters SYNCRO VIEW A mixture of up to 32 devices (including Syncro View, Ident and Matrix) can be fitted to each panel on RS485 serial interface. The maximum number of Syncro View panels on a single RS485 serial interface is 15. SYNCRO GUIDE Graphical User Interface Fire Detection Equipment Local LCD Repeater Syncro-K555 Network card required SYNCRO-K545 4 Way Conventional Zone Board 5. Networking Up to 64 Panels can be added to network 24V DC or 230V AC SYNCRO-K546 Monitored Output Board RS485 SYNCRO-KAU 2016 Fan Control Module SYNCRO AS 1-2 Loop Analogue Addressable Control Panel 24V DC SYNCRO-K556 ANC Control Module SYNCRO-K560 16 Channel I/O Board 24V DC 24V DC SYNCRO-K547 8 Way Relay Board 24V DC 11

SYNCRO MIMIC PANELS Syncro Matrix Intelligent Mimic Display System Up to 504 LED s can be controlled from any Syncro AS panel The Syncro Matrix system uses flexible, fibre optics light to illuminate areas on a floor plan, laid over a high resolution grid. Full colour printing This unique system dispenses completely with wiring and enables indicators to be moved, removed or added on site without need wiring modifications. Syncro Matrix-CP-M2 Matrix CP Mimic panel in M2 cabinet ( Max 24 zones) Syncro Matrix-CP-M3 Matrix CP Mimic panel in M3 cabinet ( Max 56 zones) Syncro Matrix-CP-S4 Matrix CP Mimic panel in S cabinet ( Max 88 zones) Syncro View Available in a range of standard enclosures to suit any application Bespoke sized units can be made upon request Choice of Red, Green or Yellow LED s Available with or without controls Same look and feel as Syncro range Syncro Matrix can easily be upgraded on site with minimal cost and eft Local LCD Control Panel repeater Up to 15 annunciators can be connected to each Syncro AS fire control panel. The large, graphic liquid crystal display and high brightness LED indicators duplicate indications on Syncro fire alarm control panel at up to 15 additional locations via a simple, two-wire serial data connection. Large liquid crystal display (240 x 64 pixels) High brightness LED indications Internal sounder Replicates all Syncro panel controls Simple, two-wire serial connection Small, Syncro style enclosure Syncro Ident Programmable LED Indication Panel 8 and 24 LED versions available as standard The compact, slimline enclosure is unobtrusive and is ideal mounting in locations where a larger control and indication unit would be unsuitable. Large versions available to special order Each indication has a dedicated field customised text to provide a concise description of indication. Multiple Syncro Ident panels can be connected to Syncro serial bus to provide a diverse range of indications at multiple locations. Programmable flashing or steady states Up to 16 x 24 way Syncro Ident can be connected to each fire panel Red, yellow or green indications/ options Common Fire, Fault and Disabled indication Customisable label identification tags 12

SYNCRO ADD ONS AND OPTIONS Industrial Cabinet Stainless Steel Cabinet Various sizes available to suit application Various sizes available to suit application 1.6mm thick zinc coated steel 1.6mm thick 316 stainless steel Powdercoated finish Polycarbonate viewing window Polycarbonate viewing window Protection rating IP 66 Protection rating IP 66 Optional 003 keyed lock any cabinet M2/M3 3 point locking on larger cabinets Polyurethane gasket foamed in place Guttered door opening Occupant Warning Control (OWC) Fits standard Syncro AS & Sigma cabinet carrier plate EVAC-SD-OWC Secure access to control via standard 003 Key switch Alarm and fault indicators High quality inbuilt panel microphone Compatible with Evactron 20,40,60,120 OWS AMPS Compatible with Tyco TGen50 OWS AMPS Quick and easy to fit Fan Control Module (SFCM) Contains 3 x AS1668 controls The Incite SyncroAS fan control module (SFCM) has been designed to enable ease of interface to building services providing smoke control in an installation. The SFCM manual controls will only operate when enable keyswitch on SyncroAS panel is in enable position. The SCFM contains 3 of 1668 control and status indicators, a general fire trip and isolate, and a lamp test button. Connects directly to SyncroAS RS485 data bus Auto - fan on and fan off modes Configurable through SyncroAS control panel or via a PC with Loop Explorer software Provides seamless fan control integration with SyncroAS panels Interfaces SyncroAS control panel to duct detectors ANC Control Controls enabled by keyswitch on Syncro AS panel Enables ease of interfacing to building services providing manual control & indication in an installation. SYNCRO-KAU2016 SYNCRO-KAU2017 4 push button controls, 8 LED indicators & 3 clean contact relays Simple 4 wire connection to Syncro AS panel, 2 power, 2 RS485 The ANC control may be mixed on RS485 bus with or expansion/control devices 13

SYNCRO ADD ONS AND OPTIONS KM-HS-M2 KM-HS-M3 19 Rack Mount Available M2 and M3 size cabinets KM -HS-M2 19 Hinged surround M2 cabinet 9RU KM-HS-M3 19 Hinged surround M3 cabinet 13RU Also suits Sigma series panels KM-ASE-RT Houses complete panel rack mounting Fully hinged to swing out complete panel Robust fully welded steel construction Epoxy powder coated to match panel colour Ideal QE90 combination panel Mounting inmation 19 IP rated enclosure ASE Brackets Available ROMTEC and CENTAUR Light grey satin finish to suit or modules Fits neatly into viewing aperture Suitable use in M3 and M4 size cabinets Mounts ASE to be flush KM-ASE-CT Sigma-M2-DocBox Sigma-M3-DocBox Doc Boxes (A4 and A3 size) Matches design and colour scheme standard Sigma and Syncro control panel range Anor addition to range, document box is designed to compliment design and colour of Sigma and Syncro range of control panels. The document box will hold up to 100 sheets of A4 documents or log books. The DocBox also doubles up as a key box providing 7 (M2) or 14 (M3) easily accessible key hooks inside enclosure. Easy to install / Key lockable Designed versatility Holds A4 size documents and Log books The document box also doubles as a key box providing 7 (M2) or 14 (M3) easily accessible key hooks inside (M2) 385W x 310H x 90D (mm) (M3) 385W x 520H x 110D (mm) 14

SYNCRO ADD ONS AND OPTIONS Syncro 4 way conventional detection zone module 4 monitored detection zone inputs To furr enhance versatility of Syncro fire alarm system, four conventional detection circuits can be connected with up to 30 detectors per circuit. Volt free fire contact Conventional control panels can be replaced with this simple module and existing conventional systems can be interfaced directly to modern analogue addressable control systems and networks. 2 monitored sounder outputs Local power supply fault input RS485 comms connection to Syncro Fire Alarm Panel Individual fault and operated indications Syncro 16 channel I/O board (Input/Output) 16 channels To add more I/O capability to extensive options already offered by Syncro control panel, up to thirty two, 16 channel I/O boards may be connected. The 16 channel boards may be mixed on RS485 bus with 8 way sounder boards, 6 way sounder boards or 4 way conventional detection zone boards to provide a very flexible system of I/O s to satisfy any requirement. Outputs open collector transistor Simple 2 wire connection to control panel Up to 32 boards supported per panel (512 Input/Output Channels) Full cause and effects on all inputs and outputs Syncro AS loop expansion card 400ma loop current per loop fitted Syncro-K586 Fitted with short circuit isolators as standard Syncro 8 way relay card These boards have 8 voltage free changeover relay contacts, each of which can be individually programmed To furr enhance versatility of Syncro AS fire alarm system, additional relay output capability can be added with Syncro relay boards. Syncro-K560 Each channel configurable as input or output The Syncro AS system can be expanded to 2 loops giving panel support an additional 127 (Hochiki) devices. Syncro-K545 Syncro-K547 Up to 32 of se boards can be connected to dedicated RS485 bus The relay boards may be mixed on RS485 bus with or expansion/control boards 15

SYNCRO SOFTWARE SYNCRO-K556 Modem Communication Module Communications module View devices near calibration limits The SYNCRO-K556 communications module enables service companies to interrogate control panels remotely via a telephone link. The module mounts on existing pillars in control panel and is supplied with all wiring and connections to enable speedy installation and commissioning. Offer value added service to customers Once connected to control panel via Loop Explorer software, users can upload configuration data and event logs or take control of system via virtual panel interface. Retrieve configuration The flexibility of Syncro system can be furr enhanced by connecting control panels and repeaters toger using a high integrity network. Check software version to see if updates are available Avoid unnecessary call outs Simple to install Dongle protected access, customers security Up to 64 nodes High integrity protocol Fully secure against short or open circuit faults Simple 2-wire loop connection A simple 2-wire connection between each panel allows events to be transmitted to or parts of system to provide indication or control on a system wide basis. Supports open ended networks retrofit applications Using Loop Explorer configuration programme, up to 64 nodes can be programmed to respond in a variety of ways to any system events as required. Network wide test and disablement functions This flexibility extends comprehensive cause and effect programming capability of Syncro control panels to entire network allowing actions, test modes or disablements to be started from any point. Graphic User Interface Fire Detection Equipment Syncro fire control panels can send data to, and be controlled by, Guide system providing a single point of co-ordination all alarms. The powerful 32 bit programme features a standard Windows look and feel and runs under Windows 2000, XP, Vista or Windows 7 Professional. The system is highly configurable in terms of style of presentation so that end user can be presented with maps, text, photographs, audio or a combination of all as required. User profiles allow system manager to control facilities available to each individual system user. 16 Dial in and observe reported faults Assist commissioning from remote location Syncro networking Syncro-Guide Retrieve event log The communications module is simple to install and requires a PSTN telephone line. This allows panel controls to be operated as if user was standing at panel. Syncro-K555 Plan maintenance visits Repeaters share network connection Network wide cause and effect logic Flexible configuration options Panels configurable to act on network events or not as required Hochiki panels supported on single network Choice of text, graphic, event list display when an event occurs Versatile event analysis Total history archive Easy to programme Secure system Cost effective compared to or systems Simple to use Unlimited map linking & zoom facility Support 100 s of graphics Display and control multiple panels Event history explore and export facility to text or HTML documents

SYNCRO & TAKTIS DETECTORS AND DEVICES A photoelectric Smoke Sensor incorporating Hochiki s unique High Permance Chamber, allows sensor threshold level to be increased, improving signal to noise ratio and reducing susceptibility to false alarms. High Permance Chamber ALK-ASN Twin alarm LEDs allow 360 viewing Locking mechanism (sensor to base) Variable sensitivity Electronically addressed Compatible Bases: YBN-R/3(WHT), YBO-BS(WHT), YBO-BSB(WHT), YBN-R/3-R/SCI Approval: AS7240.7 A multi-sensor incorporating a rmal element and a High Permance photoelectric Smoke Chamber. Has three modes controlled from Control Panel, allowing eir optical or rmal element or a rmally enhanced optical detector. High Permance chamber ACA-ASN User selectable modes Incorporates optical and heat elements Twin alarm LEDs allow 360 viewing Pulsing/non-pulsing controlled from panel Variable sensitivity Electronically addressed Compatible Bases: YBN-R/3(WHT), YBO-BS(WHT), YBO-BSB(WHT), YBN-R/3-R/SCI Approvals: AS7240.5 and AS7240.7 A multi-heat Sensor incorporating a variable Fixed Temperature heat element and a Rate Of Rise heat element, both controlled from Control Panel allowing eir rmal element or both elements simultaneously to be active in making fire decision. User selectable modes ACB-ASN Incorporates Fixed Temperature and Rate of Rise Heat elements Twin alarm LEDs allow 360 viewing Electronically Addressed Compatible Bases: YBN-R/3(WHT), YBO-BS(WHT), YBO-BSB(WHT), YBN-R/3-R/SCI AS7240.5 Classes A1,AIR,AIS,B,BR,BS,C,CR,CS, Fixed and ROR An IP67 Rated Waterproof Multi-Heat Sensor which can be used externally and is supplied with its own fixing base which is used to fix sensor. Flying leads from sensor connect directly to loop via waterproof connectors. User selectable modes ACB-ASNW Incorporates fixed temperature and rate of rise heat elements Twin alarm LEDs allow 360 viewing Pulsing/non-pulsing controlled from panel Electronically addressed IP67 rated Supplied with fixing base AS7240.5 Classes A1,AIR,AIS,B,BR,BS,C,CR,CS, Fixed and ROR 17

SYNCRO & TAKTIS DETECTORS AND DEVICES YBN-R/3(WHT) YBN-R/3(RED) YBN-R/3(BLK) A Common Mounting Base which is fully compatible with ALK-ASN, ACA-ASN and ACBASN sensors. Supplied with square cable clamps secure and reliable cable termination and is also capable of driving a remote LED if required. Electronics free (Red version YBO-R/3(RED) use with CHQWS2 Wall Sounder and CHQ-WSB Wall Sounder Beacon) Rugged wiring contacts Stainless steel contacts Takes 2.5mm 4 cables Slim profile only 8mm Facility remote indicator Quick connection via square cable clamps Available in RED use with CHQWS2 Wall Sounder and CHQ-WSB Wall Sounder Beacon YBN-R/3(WHT)-SCI Model YBN-R/3(SCI) is a sensor mounting base featuring an integral short-circuit isolator which will detect and isolate short-circuits on loop. When a short-circuit is detected during power up unit will drop power to rest of loop. The YBN-R/3(WHT)-SCI is compatible with Hochiki Analogue sensors, beacons, sounders and indicators and does not require a loop address. A remote fire LED facility is provided when a sensor is attached to base. Features integral SCI Easy to fit Slim profile Matches standard base colours NOTE: A fitted sensor will still be powered when this device is isolating. CHQ-WS2 An Addressable Loop-Powered Wall Sounder providing 8 volume levels and 51 tones with a maximum output of up to 102 db(a) (±2dB(A)) with low current consumption. Loop powered Special bases available: YBO-R/3(RED), YBO-R/ SCI(RED), YBO-R/3(WHT) and YBO-R/SCI(WHTSNDR). Single loop address addressed via TCH-B200 hand held programmer Variable sound output 90 ~ 102 db(a) (±2 db(a)) output at 1m Fits Hochiki standard or isolator base Wearproof kit available 51 User-selectable tones (all tones EN54-3 compatible) Auto-shutdown mode available Please ensure control panel compatibility CHQ-WSB An Addressable Loop-Powered Wall Sounder Beacon as per CHQ-WS2 but additionally featuring an integral beacon within horn which utilises high intensity LED technology. As per CHQ-WS2 plus: Special bases available: YBO-R/3(RED), YBO-R/ SCI(RED), YBO-R/3(WHT) and YBO-R/SCI(WHTSNDR). Independent control of sounder and beacon Variable flash frequency High intensity LED technology Auto-shutdown mode available can be set independently sounder or beacon Please ensure control panel compatibility 18

SYNCRO & TAKTIS DETECTORS AND DEVICES A Wearproof Back Box and gasket set CHQ-WS2 Wall Sounder and CHQ-WSB Wall Sounder Beacon, increases IP Rating of Sounder to IP65 external use. Designed CHQ-WS2 and CHQWSB WS2-WPK Increases sounder IP rating from IP21 to IP65 (external use) Easy to install An Addressable Loop-Powered Base Sounder, providing 13 volume levels and 51 tones with a maximum output of up to 98 db(a) (±2dB(A)) with low current consumption. The unit is designed to fit eir YBN-R/3 or YBO-R/ SCI Bases. Loop powered YBO-BS(WHT) Single loop address addressed automatically by control panel or via TCH-B200 hand held programmer 50 98 db(a) (+2dB(A)) output at 1m Fits Hochiki standard or isolator base and supports ESP sensors, beacons and remote indicator 51 User-selectable tones (all tones EN54-3 compatible) An Addressable Loop-Powered Base Sounder Beacon, providing 13 volume levels and 51 tones with a maximumoutput of up to 98 db(a) (±2dB(A)) with low current consumption. The unit is designed to fit eir YBN-R/3 or YBO-R/SCI Bases. Loop powered YBO-BSB(WHT) Single loop address, addressed by eir Control Panel or TCH-B200 50 98dB(A) (±2dB(A)) output at 1m Fits Hochiki standard or isolator base and supports ESP sensors, beacons and remote indicator 51 User-selectable tones (all tones EN54-3 compatible) Beacon and sounder can be controlled An Addressable Loop-Powered Beacon, with high-intensity LEDs and a Fresnel lens design which produces a highly visible flash. The casing exactly matches Hochiki Analogue Sensor range in shape and colour providing seamless integration. High Intensity LED technology CHQ-AB(WHT) 1 Hz flash frequency Addressable via TCH-B200 Up to 127 devices per loop Choice of 3 lens colours (red, amber and blue An Addressable Loop-Powered Remote Indicator, with high-intensity LEDs and a Fresnel lens design which produces a highly visible signal. The casing exactly matches Hochiki Analogue Sensor range in shape and colour providing seamless integration. The unit also features two monitored inputs. High Intensity LED technology CHQ-ARI(WHT) Addressable via TCH-B200 Up to 127 devices per loop 19

SYNCRO & TAKTIS DETECTORS AND DEVICES CHQ-CB CHQ-WB A Mains Relay Controller providing a single, mains rated relay output control of such devices as dampers, extractors or plant and equipment shutdown. The monitored input can be used local power supply fault monitoring or as a general purpose input. Also available as a DIN Rail mountable version. Loop-powered CHQ-MRC(SCI) An Addressable Loop-Powered Ceiling Beacon, with a high intensity LED and a custom designed free-m optic which produces a highly visible flash. Coverage diameters include 5m, 7.5m, 10m and 15m diameter. The unit is designed to fit YBN-R/3, YBN-R/3(SCI), YBOBS or YBO-R/SCI(RED), and is available in red or white LEDs. An Addressable Loop-Powered Wall Beacon, with a high intensity LED and a custom designed free-m optic which produces a highly visible flash. Coverage diameters include 5m, 7.5m, 10m and 15m diameter. The unit is designed to fit YBN-R/3, YBN-R/3(SCI), YBOBS or YBO-R/SCI(RED), and is available in red or white LEDs. Both models feature an integral short-circuit isolator. Loop Powered Single loop address via TCH-B200 High Intensity LED technology 0.5/1 Hz flash frequency Choice of 2 LED colours (red and white) Approved to AS7240.23 Category C Operating voltage 17-41 Vdc Loop Powered Single loop address via TCH-B200 High Intensity LED technology 0.5/1 Hz flash frequency Choice of 2 LED colours (red and white) Approved to AS7240.23 Category W Operating voltage 17-41 Vdc Single loop address Single mains rated relay contact Relay contact rated at 250Va.c. @ 5 amp (resistive) & 48Vd.c. @ 2 amp (resistive) Auxiliary monitored input Screw terminals & flying leads easy cable termination DIN rail version available Both models feature an integral shortcircuit isolator CHQ-DIM(SCI) A Dual Input Module designed to interface to a variety of inputs such as door contacts, sprinkler flow/door switches and plant equipment. Also available as a DIN Rail mountable version. Both models feature an integral short-circuit isolator. Loop powered Single loop address Two independent inputs monitoring of volt-free contacts Each input can be configured to monitor eir normally open or normally closed contacts DIN rail version available Both models feature an integral short-circuit isolator CHQ-PCM A Plant Control Module with four independent change-over relay outputs, with N/O and N/C volt free contacts and four inputs. These outputs can be driven separately by fire alarm control panel and can be used control of devices such as dampers or plant and equipment shutdown. Also available as a DIN Rail mountable version. Both models feature an integral shortcircuit isolator. 20 Single loop address Loop powered 4 change-over relay outputs 4 independent inputs monitoring of volt-free contacts E ach input can be configured to monitor eir normally open or normally closed contacts DIN Rail version available Both models feature an integral Short-Circuit Isolator

SYNCRO & TAKTIS DETECTORS AND DEVICES A Dual Relay Controller designed to provide two general-purpose relay outputs, each output can be controlled independently and used to control dampers, plant and equipment shutdown. The monitored input can be used local power supply fault monitoring or as a general-purpose input. Also available as a DIN rail mountable version. Loop powered Both models feature an integral short-circuit isolator. CHQ-DRC(SCI) Single loop address Two independently controlled changeover relays Relays contact rated at 30Vd.c. at 1 amp Auxiliary monitored input DIN rail version available Both models feature an integral shortcircuit isolator A Dual Zone Module designed to allow up to 60 conventional detectors (30 per zone) to be interfaced to Hochiki s analogue addressable system. Also available as a DIN Rail mountable version. Both models feature an integral shortcircuit isolator. Single loop address CHQ-DZM(SCI) Supports two independent zones of conventional detectors Both zones fully monitored Short/ Open Circuit Requires an auxiliary 24Vd.c. supply DIN rail version available Both models feature an integral short-circuit isolator A Dual Sounder Controller, which has been designed to provide two sounder outputs (that can be driven separately) with full fault monitoring. The monitored input can be used local power supply fault monitoring or as a general-purpose input. Features an integral short-circuit isolator. Single loop address CHQ-DSC(SCI) Two independent sounder circuits Each circuit fully monitored Open and Short Circuit faults Each alarm circuit fused at 1 amp Auxiliary monitored Input Outputs are synchronised and can be driven continuously or intermittently 24Vd.c. auxiliary power required Features an integral short-circuit isolator A Single Zone Monitor designed to allow up to 6 conventional detectors to be interfaced to Hochiki s analogue addressable system. Also available as a DIN Rail mountable version. Both models feature an integral short-circuit isolator. Loop powered CHQ-SZM(SCI) Up to 6 Conventional Detectors Single loop address Remote LED output Fully monitored Short and Open Circuit faults DIN rail version available Both models feature an integral short circuit isolator 21

SYNCRO & TAKTIS DETECTORS AND DEVICES CHQ-POM A Powered Output Module designed to supply a nominal 24 V dc at various, userselectable current levels from 2 to 32 ma (in increments of 2mA). The unit is small enough to be added to or third-party devices reby allowing a range of equipment to be added to analogue loop. Supplies a nominal 24 V dc at various current levels, 2 ma to 32 ma in increments of 2 ma The unit also features two monitored inputs. User-selectable current output Includes two monitored inputs Small design, provides simple connectivity to analogue loop third-party devices Colour-coded flying leads simple installation Addressed with TCH-B200 hand held programmer CHQ-SIM A Single Input Module designed to allow a single monitored input to be connected to analogue loop. This provides a compact, low-cost option where installation of larger CHQ Smart-Fix range of modules might be difficult. Includes a single monitored input Small design simple provision of a monitored input onto an analogue loop Flying leads easy installation Addressed with TCH-B200 hand held programmer Please ensure control panel compatibility CHQ-ADAPTOR 22 The CHQ-ADAPTOR is designed to allow Smart-Fix range of CHQ Modules to be housed in existing enclosures originally designed first generation CHQ-OEM Modules by modifying footprint of unit. Allows PCB component of a CHQ Module to be housed in an enclosure Footprint matches older enclosure sizes

SYNCRO & TAKTIS DETECTORS AND DEVICES Addressable manual call point Fast Response HCP-E-ADD Status LED Addressed using handheld programmer Complete with back box Wearproof addressable manual call point Fast Response HCP-E-ADD-WP Status LED Addressed using handheld programmer Complete with back box IP rated IP67 Alarm Acknowledgement Facility. Used to allow local alarm investigation prior to signalling full alarm outputs. Fully compatible with Syncro AS range SYNCRO AAF Meets AS7240.2 requirements Acknowledge time settings 30 or 60 seconds Investigate time between 30 to 180sec in 30 sec intervals Button to acknowledge false alarm Loop powered - no external power required Fits standard Australian mounting block A hand held address programmer designed to address range of detectors and or addressable devices such as YBO-BS(WHT) base sounder. Designed to be light, robust and easy to use it operates from a single PP3 size 9v battery which can provide up to 8000 operations. Lightweight design TCH-B200 Quick and reliable addressing Up to 8000 address settings from one battery TCH-200 : Includes CO detection. 23

SYNCRO & TAKTIS DETECTORS AND DEVICES CHQ-BACKBOX The CHQ-Backbox is designed installations where CHQ range of modules - CHQDIM(SCI), CHQ-SZM(SCI), CHQ-DZM(SCI), CHQDSC(SCI), CHQ-MRC(SCI), CHQ-DRC(SCI) and CHQ-PCM - require mounting within a glanded enclosure. MBB-1 Provides glanded cable connections Robust design Compatible with all CHQ modules Splashproof Base Backbox providing a splash proof and secure fixing Hochiki analogue and conventional marine approved range of sensors and detectors and ir associated bases. Provides an aestically pleasing solution where surface fixed devices are required. The housing supports four 20mm glanded entries cabling access. 4 glanded cable entry holes (glands not supplied) Colour matched Approved detector and base range Provides moisture and dust resistant fitting Ideal bulkhead fitting Suitable marine use YBO-BS-COV(W) SMB-1 Protective Cap. A protective cap which can be fitted to YBO-R/SCI(WHT) isolator base, YBOBS(WHT) or YBO-BSB(WHT) sounder bases when se devices are being used without a detector fitted. Protects wiring terminals on isolator bases and base sounders An IP66 rated, grey (RAL7035) enclosure designed use with Hochiki range of Modules. Supplied with a transparent black lid as standard. Used in conjunction with SMB-ADAPTOR this enclosure can house any of PCB assemblies from Hochiki Smart-Fix module range Quick-release screws Easy to fit Available in ivory or white Polyurethane gasket provides IP66 protection Corrosion free, resistant to most alkaline and acid Temperature resistance to +70 C, Impact resistant, and Nonflammable 32 knock-outs Dimensions L 254 x W 180 x H 90 24

SYNCRO & TAKTIS DETECTORS AND DEVICES An IP66 rated, grey (RAL7035) enclosure designed use with Hochiki range of DIN Modules. Supplied with a transparent black lid as standard. The unit is supplied with a DIN rail section (plus fixings) and will accept up to six Hochiki DIN rail modules, side-by-side. Designed to house up to 6 Hochiki DIN rail Modules SMB-2 Quick-release screws Polyurethane gasket provides IP66 protection Corrosion free, resistant to most alkaline and acid Temperature resistance to +70 C Impact resistant, and non-flammable 32 knock-outs Supplied with DIN rail and fixings Dimensions L 254 x W 180 x H 160 An IP66 rated, grey (RAL7035) enclosure designed use with Hochiki range of DIN rail modules. Supplied with a transparent black lid as standard. The unit is supplied with a DIN rail section (plus fixings) and will accept up to four Hochiki DIN rail modules, side-by-side. Designed to house up to 4 Hochiki DIN rail Modules SMB-3 Polyurethane gasket provides IP66 protection Corrosion free, resistant to most alkaline and acid Temperature resistance to +70 C 20 knock-outs Supplied with DIN rail and fixings Dimensions L 180 x W 110 x H 165 A Duct Probe Housing associated with analogue ALK-ASN detectors and to be mounted on outside of an air duct purpose of monitoring air within duct. (shown with sensor fitted not supplied). Allows air duct sampling using standard detector or sensor. Test hole on cover. Simple installation/ maintenance. Sensitive flow indication Installer-friendly connection of cables. DH-98-ASA 25

FIRENET SYSTEMS Firenet Overview Addressable Panels Fully compatible with Hochiki addressable detector range. High resolution LCD with large characters & backlighting. High level interface to VESDAnet. Site programmable using Microsoft Windows compatible configuration editor Digifire Windows compatible graphical PC interface. Simple to operate LCD menu with on screen prompts. Easy installation operation and maintenance. Keyswitch to enable controls. Features Programmability Fully monitored inputs/outputs ancillary equipment Voltage free solid state outputs which are fully programmable Utilises Hochiki programmable loop input/output devices Each I/O and/or loop device has 40 characters of text description All input devices can be allocated to a specific zone with a 40 character text description Up to 999 zones allowed in system Digifire Graphical PC interface FireNet Full monitoring and control from graphical user interface (GUI) Simple operation Menu driven with clear prompts user Operator controls through touch keys and numeric keypad Fire fighters controls clearly identified Full system control can be replicated at any location using multiple displays FIRENET - 2S - 1 loop, size 2, ASE FIRENET- 3-2 loop, size 3, ASE Capacity 1922 loops of 127 Hochiki analogue/addressable devices High level interface to VESDAnet 1000 events logged, comprising of alarms, faults, isolates & history Dimensions FireNet-2 cabinet 660H x 500W x 170D Optional battery box 225H x 500W x 170D FireNet-3 cabinet 974H x 560W x 225D Optional battery box 487H x 560W x 225D AFP Approval Listing No:1373 AS compliance Complies with AS 1603.4 & AS 4428.1 HRE Compatible The FIRENET is compatible with Hochiki HRE protocol used previously with AB3000, F9000 & F10000 Fire Panels by inclusion of supplementary HRE loop card FN-MIMIC FN-REPEATER FIRENET MIMIC PANEL - NIB TYPE FIRENET SURFACE MOUNT REPEATER PANEL 2 line LCD display Full size backlit LCD display Scroll only Full Control or scroll only Surface mount with silver finish fascia DIGIFIRE The operator is able to fully monitor and control system from graphical user interface (GUI) in accordance with pre-defined password controlled levels of access. The program provides a series of interlinked maps such as overall site plan and individual floor plans detailing location and status of fire alarm detectors. Maps can be generated using tools provided, or imported and manipulated within system. Fire System components such as detectors, panel cards and loops - displayed in m of icons - change ir status in accordance with real time state of fire alarm system. 26 V-PANEL The FireNet Virtual Panel (Vpanel ) is a software application program that allows you to access, view and control your FireNet alarm panel from any Microsoft Windows based computer. Connected to FireNet alarm system (via a RS232 port) Vpanel program provides a dynamic display identical in appearance and operation to display and controls on FireNet panel.

FIRENET DETECTOR AND DEVICES A Photoelectric Smoke Sensor incorporating Hochiki s unique High Permance Chamber which allows sensor threshold level to be increased, reby improving signal to noise ratio and reducing susceptibility to false alarms. High Permance chamber ALK-AS Twin fire LEDs allow 360 viewing Locking mechanism (sensor to base) Variable sensitivity Electronically addressed Compatible bases: YBN-R/2NA, YBOBS, YBO-BSB, YBO-R/SCI Approval: AS7240.7 A Multi-Sensor incorporating a rmal element and a High Permance photoelectric smoke chamber. High Permance chamber ACA-E Incorporates Optical & Heat elements Twin fire LEDs allow 360 viewing Variable sensitivity Electronically Addressed via TCH-B200 handheld programmer Compatible bases: YBN-R/2NA, YBOBS, YBO-BSB, YBO-R/SCI Approval: AS1603.1 & AS1603.2 A Multi-Heat Sensor incorporating a variable Fixed Temperature heat element and a Rate Of Rise heat element, both controlled from Control Panel allowing eir rmal element or both elements simultaneously to be active in making fire decision. User selectable modes Incorporates Fixed Temperature and Rate Of Rise Heat elements ACB-AS Twin fire LEDs allow 360 viewing Electronically Addressed Compatible bases: YBN-R/2NA, YBO-BS, YBO-BSB, YBO-R/SCI Approval: AS1603.1. Type A, B, C and D An IP67 Rated Waterproof Multi-Heat Sensor which can be used externally and is supplied with its own fixing base which is used to fix sensor. Flying leads from sensor connect directly to loop via waterproof connectors (Not supplied). User selectable modes ACB-ASW Incorporates Fixed Temperature and Rate Of Rise Heat elements Twin fire LEDs allow 360 viewing Electronically addressed IP67 rated Supplied with fixing base Approval: AS1603.1 Type A, B, C and D A Common Mounting Base which is fully compatible with ALK-AS, ACA-ASN and ACB-AS sensors. Supplied with square cable clamps secure and reliable cable termination and is also capable of driving a remote LED if required. Electronics free / Stainless steel contacts (Red version YBO-R/3(RED) use with CHQWS2 Wall Sounder and CHQ-WSB Wall Sounder Beacon) Facility remote indicator YBN-R/2NA Takes 2.5mm2 cables Slim profile only 8mm Rugged wiring contacts Quick connection via square cable clamps Available in RED use with CHQ-WS2 Wall Sounder and CHQ-WSB Wall Sounder Beacon 27

FIRENET DETECTOR AND DEVICES YBN-R/3(SCI) YBO-BS A Loop Isolator Base which is fully compatible with Hochiki analogue Sensors, Beacons, Sounders and Indicators. The unit incorporates an amber LED to show when it is isolating a section of loop. (Red version YBO-R/ SCI(RED) use with CHQ-WS2 Wall Sounder & CHQ-WSB Wall Sounder Beacon) or rmal element or both to be active in making fire decision. Detects short circuits on loop An Addressable Loop-Powered Base Sounder, providing 13 volume levels and 51 tones with a maximum output of up to 98 db(a) (±2dB(A)) with low current consumption. The unit is designed to fit eir YBN-R/3 or YBO-R/SCI Bases. Loop powered Status LED Connection of up to 127 per loop Quick connection via square cable clamps Available in RED use with CHQ-WS2 Wall Sounder & CHQ-WSB Wall Sounder Beacon Single loop address addressed via TCH-B200 hand held programmer 50 98 db(a) (+2dB(A)) output at 1m Fits Hochiki standard or isolator base and supports ESP sensors, beacons and remote indicator 51 User-selectable tones (all tones EN54-3 compatible) CHQ-AB An Addressable Loop-Powered Beacon, with high-intensity LEDs and a Fresnel lens design which produces a highly visible flash. The casing exactly matches Hochiki Analogue Sensor range in shape and colour providing seamless integration. High Intensity LED technology 1 Hz flash frequency Addressable via TCH-B200 Up to 127 devices per loop Choice of 3 lens colours (red, amber and blue) CHQ-DSC(SCI) A Dual Sounder Controller, which has been designed to provide two sounder outputs (that can be driven separately) with full fault monitoring. The monitored input can be used local power supply fault monitoring or as a general-purpose input. Features an integral short-circuit isolator. Single loop address Two independent sounder circuits Each circuit fully monitored Open and Short Circuit faults Each alarm circuit fused at 1 amp Auxiliary monitored Input Outputs are synchronised and can be driven continuously or intermittently 24VD.C. auxiliary power required Features an integral short-circuit isolator CHQ-DRC(SCI) 28 A Dual Relay Controller designed to provide two general-purpose relay outputs, each output can be controlled independently and used to control dampers, plant and equipment shutdown. The monitored input can be used local power supply fault monitoring or as a general-purpose input. Also available as a DIN Rail mountable version. Loop powered Both models feature an integral short-circuit isolator. DIN rail version available Single loop address Two independently controlled changeover relays Relays contact rated at 30Vd.c. at 1 amp Auxiliary monitored input Both models feature an integral shortcircuit isolator