ELECTRONIC HUMIDISTAT: H270

Similar documents
ELECTRONIC HUMIDISTAT: H200

the security screw.) Insert cable in the central hole of the base. Align the base and mark the location of the two mounting holes on the wall.

INSTALLATION & USER MANUAL

Humidity Controller Specification and Installation Instructions. Model HRO20

± 3% or better at 40%RH and 23ºC [73ºF] 0.8 mm 2 [18 AWG] minimum

Temperature Controllers

VH7200 Humidistat Series For Humidification & Dehumidification Control For Commercial HVAC Applications (Issue Date January 22, R7)

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

T7984 A,B,C Electronic Modulating Control Thermostats

EC Series Wall Unit Humidifier

OVEN INDUSTRIES, INC.

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

TCI-W-U Series Wall Mounted Controller Installation and Operation Manual IOM-525

T6984 A,D,E Electronic Floating Control Thermostats

CP CP

VT8300 Series Installation Guide 24 Vac Low Voltage

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Safety, Installation, and Operation Manual

TER Active Room Temperature Sensor (Controller),

T6984F,G Electronic Floating Control Thermostats

0-10 V Wall & Duct Humidistat Installation Instructions

OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems

Networkable Fan Coil Controller Specification and Installation Instructions

Oxygen (O2) Single-Point Gas Detection System

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

02/11/2015

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

02/11/2015

Siemens Thermostats. RDY2000BN Thermostat

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

DT968C C.T. BATH CONTROLLER

Safety & Installation Instructions

Temperature & Humidity Controllers

HAI Omni-Bus Network Installation. 5. Typical Application

RC-2000 Thermostat Installation Instructions

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

I/A Series 716C 1/16 DIN Temperature Controller

VENTURI NOZZLE SYSYTEM Specification Sheets ALL STAINLESS STEEL COMPRESSED AIR NOZZLE HUMIDIFIERS. With ON/OFF or Proportional Controls

RE-PR3-E-27 3-Phase Panel Mount 27kW

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat

Fan Coil Thermostat. Specification & Installation Instructions TFC54F3Y1. Technical Data

VT7600 Series Programmable & Non-Programmable Thermostats With Humidification & Dehumidification Strategy For Commercial HVAC Applications

T6590 Series FAN-COIL CONTROLLER

VisionPRO 8000 with Wi-Fi

Heat Link. Technical Guide

IntelliPack : 800 Series

7EF/7HF/7EC/7ES Temperature Controllers

JDDT1 - Single Stage Digital Thermostat

ET10 Series Stand-alone LCD Fan Coil Thermostat

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

T6590 Series FAN-COIL CONTROLLER FEATURES APPLICATIONS PRODUCT DATA

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Lynergy Comfort Control SCR Electric Heater Application Guide


Analog Room Pressure Monitor RPC Series

Datasheet: K-22 LO Sensor

CLEANROOM MONITOR CR3A Network - Installation Instructions

INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS

Sensors Product Overview. Reliable And Accurate Honeywell Sensors

DIGITAL METERS Large Display Temperature Meters Instruction Manual

8000 Series Programmable & Non-Programmable Thermostats for Heat/Cool Applications

DXM CONTROLS. DXM Digital Heat Pump Controllers. Application, Operation, & Maintenance. Table of Contents

UNIT DIGITAL CONTROLS APPLICATION, OPERATION & MAINTENANCE

Programmable Touchscreen Thermostats. Disconnect power before beginning installation.

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

Mark 25 Ultrapure Water Conductivity Analyzer

LuxPro Thermostats NEW MULTI-STAGE TOUCHSCREENS. Features & Programming. Mt. Laurel, NJ

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Duct and Rough Service Carbon Monoxide Sensor

UDC100 Universal Digital Controller Specifications

INTAC Microprocessor Humidifier Controller

Two-Channel Gas Controller

Installer Guide. WARNING Important Safety Information. 1 Specifications

TEMPERATURE CONTROLLER

ELECTRONIC COMMUNICATING THERMOSTAT

CXM/DXM. Application, Operation & Maintenance Instructions 97B0003N08 Revision: 01/10/05. CXM/DXM Digital Heat Pump Controllers.

TC-9102 Applications

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

TEC210x-2 Series Networked Thermostats

RES-210 (-211, -220, -221) / RES-420

EL-TSTAT-8820 Safety & Installation Instructions

Pump-Up Controller MODEL 4062

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

B-40/B-41 Modulating Temperature Controller

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE HEATPUMP 100% OUTDOOR AIR VERSION Telephone:

EC2-5x2 Series Condensing Unit Controllers

ESSEX ENGINEERING CORPORATION

Transcription:

ELECTRONIC HUMIDISTAT: H0 ONE OR TWO STAGES HUMIDITY SUPPLY OUTDOOR TEMPERATURE RESET DESCRIPTION The H0 series low voltage, microcomputerbased PI (proportional and integral) humidistats are designed for accurate humidification and/or dehumidification control in commercial applications such as: hospitals, schools, office buildings, retail stores, museums, computer rooms, etc. The H0 series is available with one or two outputs for maximum flexibility. Outputs can be of the following type: proportional, on/off, and pulse width modulation (PWM). Two additional inputs are provided in order to perform unique functions: humidity setpoint reset based on outdoor air temperature and proportional high limit override. The former function minimizes condensation on window surfaces during cold outdoor temperatures by automatically lowering the humidity setpoint as the outdoor temperature drops. The latter function improves accuracy and safety by throttling back the humidifier control output if the humidity level reaches unacceptably high levels. There are many different types of mounting configurations available. Sensing options include remote duct and room as well as integral room and duct. Setpoint adjustment can be either concealed or exposed, adding even more versatility to the product. Exposed models feature internally selectable minimum and maximum setpoint knob stops. In order to facilitate periodic recalibration, the H0 series contains a unique autocal key, which permits instant recalibration (see dimension drawing on page for location). Each humidistat is computer calibrated and factory programmed with default parameters. All control parameters (such as proportional band, stage differential, etc.) may be changed in the field with the H programming tool without having to remove the thermostat cover. The H also doubles as a diagnostic tool and indicates the status of all the inputs and outputs, and will reduce troubleshooting time by quickly identifying the specific problem. Fig. Wall mounted humidistat Features Benefits Microcomputerbased design with PI algorithm Exceptional accuracy One or two outputs Controls humidification and dehumidification equipment On/off and/or proportional outputs Greater flexibility Direct or reverse acting outputs Controls humidification and dehumidification equipment Integrated and remote sensing Larger choice of mounting options Autocal button Permits instant recalibration Concealed or exposed set point Can be used in a large variety of environments Ouput signal to digital indicating devices Increases functionality of product Optional H diagnostic tool with digital display Simplifies troubleshooting Sensor failure protection Prevent water dammage Humidity setpoint reset based on outdoor temp. Prevents window condensation in colder climates Proportional high limit override Prevents costly damage due to overhumidification CE approved Can be sold in European markets

TABLE : ORDER CODE WIRING H0 AB CD EF GH A Output no. ( controlled device ) ON/OFF ( min. time based) (PWM) VAC (PWM) VDC Analog 00 Volts DC B Output no. ( controlled device ) 0 Not installed ON/OFF ( min. time based) (PWM) Volts AC (PWM) Volts DC Analog 00 Volts DC Signal transmitter (00 VDC) (V=, V) Signal transmitter (0 VDC) (0.V= ;. V=) C Output no. and control mode Humidify Dehumidify Humidify ( no. ) and dehumidify ( no. ) Dehumidify ( no. ) and humidify ( no. ) D Main sensor location Sensor 0 Not installed None Inside humidistat ( Local ) H0 Duct mount ( stat on duct ) H0 Duct mount ( stat on wall ) H Remote wall mount H0 E Setpoint adjustment User adjustable Blind cover F Future option 0 Unused G Duct humidity supply high limit 0 Without sensor With H duct mounted humidity sensor H Outdoor temperature reset input 0 Without sensor With S duct mounted outdoor temp. sensor Example: H0 0 One SCR 0 to 0 volts humidify output and one relay dehumidify output. Humidistat and sensor are duct mount. Setpoint is user adjustable. A remote duct mounted high limit is installed in the supply. An outdoor temperature sensor is installed to reset the humidity setpoint. Resolution: 0. % for retransmit only See sensor specications for dimensions of sensors Note: the complete order code includes the sensor that will be shipped with the humidistat. Single transformer INPUT HUMIDITY SIGNAL OUTDOOR RESET 0 Vdc 0 ON/OFF OUTPUTS Fig.: Wiring diagram with single transformer Multiple transformers INPUT HUMIDITY SIGNAL OUTDOOR RESET 0 Vdc 0 Fig.: Wiring diagram with multiple transformers Note: both of the above wiring diagrams show how to wire output of type,, and (switched vac). For outputs of type and (vdc out) refer to wiring diagrams and on next page. or VALVE or VALVE S TEMPERATURE SENSOR or VALVE or VALVE S TEMPERATURE SENSOR

PROPORTIONNAL OUTPUT PROPORTIONNAL AND TRANSMITTER OUTPUT 0 to 0 Vdc ELECTRONIC MOTOR or "SCR" 0 to Vdc 0 to 0 Vdc TRANSMITTER DDC SYSTEM or METER 0 to 0 Vdc ELECTRONIC MOTOR or "SCR" 0 to 0 Vdc ELECTRONIC MOTOR or "SCR" INPUT N/A N/A INPUT SENSOR OUTDOOR TEMP. SENSOR 0 Vdc 0 Fig.: Wiring diagram with two analog outputs 0 Vdc 0 Fig.: Wiring diagram with one analog and one transmitter output APPLICATION EXAMPLE: Steam humidification system controlled by a 0 to 0 Vdc valve wired to output #. Remote humidity display using 0 to Vdc signal is wired to output #. The humidity sensor is located in the return air duct. A proportional high limit humidity sensor is installed in the supply duct. An outdoor temperature sensor is installed in the fresh air duct. Humidistat model number: H00 Fig.: Application example

TABLE : HUMIDISTAT ACCESSORIES H0 H0 H H0 S H Internal humidity sensor for H0 humidistat and for H0 remote wall sensor. Duct humidity sensor to mount directly onto the back of any H0 humidistat. Duct humidity sensor to mount directly onto the supply or return of the ventilation duct. Wall humidity sensor to mount in any remote location. Outdoor temperature sensor to lower the setpoint in cold season. Programming tool for troubleshooting, viewing and modifying humidistat parameters. 0000 Replacement lexan (cover sticker) for H0 humidistat. 000 Humidistat replacement base with connector (H0 internal humidity sensor not included). H0 INTERNAL SENSOR H0 DUCT SENSOR H REMOTE DUCT SENSOR This humidity sensor can be mounted directly on 000 humidistat base. H0 REMOTE WALL SENSOR This humidity sensor can be mounted directly onto the back of any H0 humidistat, with the supplied hardware. This transforms the humidistat into a ductmounted humidistat. S OUTDOOR TEMPERATURE SENSOR This humidity sensor can be mounted directly onto the supply or return of the ventilation duct. The H0 may be located on the wall with humidity sensing from the remote H sensor location. H PROGRAMMING TOOL This humidity sensor can be wall mounted in any remote location. The humidistat may be located on the duct or other location, with humidity sensing from the H0 sensor location. This outdoor temperature sensor is used to lower the humidity setpoint to prevent condensation on windows and structures. It is usually installed in the fresh air duct. This tool is used to change humidistat parameters. It is also useful for troubleshooting. Just plug it in the humidistat through the casing. See page for more details. WARNING: All H0 humidistats are intended to control equipment under normal operating conditions. Where failure or malfunction of H0 series humidistats could lead to an abnormal operating condition that could cause personal injury or damage to the equipment or other property, other devices (limit or safety controls) or systems (alarm or supervisory) intended to warn of, or protect against, failure or malfunction of H0 humidistats must be incorporated into and maintained as part of the control system.

CONTROL SCHEMATIC: HUMIDIFICATION SET POINT DEHUMIDIFICATION d d HUMIDIFICATION DEHUMIDIFICATION % % % % Fig. Control schematic pb db pb = proportionnal band d = differential between output # and # db = dead band between humidification and dehumidification FIGURE : HUMIDITY SETPOINT RESET BY OUTSIDE TEMPERATURE OUTSIDE AIR TEMPERATURE HUMIDITY SETPOINT RESET BY OUTSIDE TEMPERATURE F F F 0 F 0 F re = % HT = F LT = 0 F USER SETPOINT % % %RH Note: re, HT, LT parameters can be changed with C programming tool The H0 humidistat has an optional outdoor temperature sensor. This sensor is used to reset the humidity setpoint during the cold season to minimize condensation on windows and building structures. When the outdoor temperature falls below the selected high temperature, parameter HT ( F in the example Figure ), the humidity setpoint will start to decrease. The lowest humidity setpoint will be reached at selected low temperature, parameter LT (0 F). The setpoint decrease from original setpoint down to the lowest setpoint determined by the parameter re. In the example, Figure, re was set to, therefore the humidity setpoint dropped from % to. If you don t use the outdoor reset feature, put a jumper between terminals and (supplied with the humidistat.)

TABLE : H HUMIDISTAT PROGRAMMING TOOL CODE VALUES DEFAULT VALUE DESCRIPTION Db 0 to 0 % R.H. % R.H. Dead Band between humidification and dehumidification. SL 0 to 00 % R.H. % R.H. Supply Limitation: High humidity limit in the supply duct (H0 only) d Pb o o cc 0 to % (of proportional band) 0 =. % R.H. =. % R.H. =. % R.H. =. % R.H. =. % R.H. 0 = Humidification = Dehumidification 0 = Humidification = Dehumidification = Without integral = With integral t 0 = On/off = minutes = second t 0 = On/off = minutes = second ra 0 = C = F Differential for output #": Shift for output relative to output =.% R.H. Proportional Band "Control Code" DO NOT CHANGE "Output #" Action for output no "Output #" Action for output no "Time #" Time period for output no "Time #" Time period for output no. "Range" Temperature Scale Ca ± % Calibration ( deviation mode: DO NOT MODIFY: USE AUTOCAL PROCEDURE; FOR H00 TRANSMITTER, USE THE ZERO POTENTIOMETER ON THE TRANSMITTER. ha 0 à "Hardware assembly" Code related to thermostat model and entered at initial setup at the factory. it to = TO MINUTES 0 "Integral time" Error integration time. Lt 0 à 0 C (0 à 0 F) 0 F "Lower temperature" minimum outside temperature for setpoint reset (model H0 only) Ht 0 à 0 C (0 à 0 F) F "Higher temperature" maximum outside temperature for setpoint reset (model H0 only) re à % R.H. 0 % R.H. "Reset Minimum humidity value ( % HR ) (model H0 only) Example: re =. Humidity setpoint will be reset from selected setpoint to, from Ht to Lt AIR SUPPLY The H0 includes a high limit circuit. This allows the use of a second humidity sensor to limit the humidity in the supply air. Input signal goes to terminals # on the humidistat. High limit setpoint is preprogrammed at %. It can be readjusted using the C service tool. If you don t use the high limit feature, connect a. Meg Ω, ¼ watt resistor between terminals and 0 (supplied with the humidistat.) Remember: this high limit function is not a safety device. For critical situations, provide installation with normal protections required to ensure a safe operation. CONTROL OUTPUT LEVEL TABLE % SUPPLY HUMIDITY Example showing proportional high limit override signal in supply duct.

AUTOCAL PROCEDURE. Measure the room humidity near the Viconics humidistat with an accurate hygrometer.. Turn the humidistat set point dial to match the reading of the hygrometer.. Push and hold the Autocal button for more than seconds or until the internal red light turns On and Off. SENSOR FAILURE PROTECTION The sensor is the most sensitive part of the humidistat and also the most exposed. In the case of a sensor failure in humidification mode, the H00 will automatically assume a failsafe output of. SPECIFICATIONS Operating Conditions: C to 0 C ( F to F ) Control: to % R.H. noncondensing Sensor: to R.H. (see Note.) Resolution: ± 0. % Repeatability: 0. % Accuracy and sensor interchangeability: ± % R.H. from 0 to 00 % R.H. Range: 0 % to 0 % R.H. for to 0 C ( F to F ) Temperature effect: 0.0 % / F Outputs: Isolated Triac: 0 Vac at ½ A max.* 0 to VDC into KΩ resistance min. 0 to 0 VDC into KΩ resistance min. 0/ VDC at 0 ma max.for both outputs Power: VAC %, ; 0/0 Hz; VA Base and casing: Offwhite; self extinguishing ABS plastic * Triac outputs can only switch AC loads. Use relays when switching dc loads. Note. Humidity sensor: Solid state humidity sensor. Suitable for normal, clean air. Not to be used in corrosive or harmful environment. DIMENSIONS Wiring from top Security screw." [mm]." [mm] Cover." [mm] Fig.: Dimension drawing." [mm] Wiring from back Base." [mm] "Autocal" button (Invisible).00" [mm] Cover.0" [mm]." [mm].0" [0.mm]." [.mm] Note: Specifications and equipment are subject to change without prior notice. 0." [.mm] TABLE : SENSOR CHARACTERISTICS Voltage between black and white wire, terminals # and # OUTPUT 0 %.0 V %. V 0 %. V %. V 0 %. V %. V 0 %. V %.0 V 0 %.0 V %. V 0 %. V %. V 0 %. V %. V 0 %.0 V %. V 0 %. V %.0 V 0 %. V %. V 00 %. V Viconics Electronics Inc., Langelier Blvd, StLeonard, Quebec, Canada HP K LITH0XE0 H0.doc www.viconics.com sales@viconics.com