RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

Similar documents
Analog Room Pressure Monitor RPC Series

0-10 V Wall & Duct Humidistat Installation Instructions

Accuracy by Design Products for the HVAC Professional

Water Detection Controllers

Duct and Rough Service Carbon Monoxide Sensor

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

ELECTRONIC HUMIDISTAT: H270

Hygro/hygrothermal transducers (hygrometric)

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

Humidity Controller Specification and Installation Instructions. Model HRO20

Hygro/hygrothermal transducers (hygrometric)

CMT MANUAL 6. NMC SENSORS

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

HUMIDISTATS and Electronic humidity controls

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

TCI-W-U Series Wall Mounted Controller Installation and Operation Manual IOM-525

Installation Manual. esense Duct (Disp) Figure 1 The esense Duct with and without display

BC-HTO RELIABLE SENSING TECHNOLOGY

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

for relative humidity and temperature

Beck. The differential pressure transmitter for air

INSTALLATION & USER MANUAL

Model Smart Digital Humidistat

Sensors Product Overview. Reliable And Accurate Honeywell Sensors

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

Oxygen (O2) Single-Point Gas Detection System

QPM21 Series Duct CO 2 and Air Quality Sensors

Power and Energy Management Solutions

250mm dia straight pipe length SP4 SP3. Air volume

ELECTRONIC HUMIDISTAT: H200

Read and save these instructions. VAPOR-LOGIC 3. Microprocessor-based humidifier control system Installation and operation manual

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

TER Active Room Temperature Sensor (Controller),

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Warranty Registration

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

SINGLE CHANNEL SYSTEM TWO CHANNEL SYSTEM

CLEANROOM MONITOR CR3A Network - Installation Instructions

RF Programmable Room Thermostat Installation Instructions

Outside Humidity and Temperature Sensor

TM-3100 Series Room Temperature Sensor

Room air quality sensors

Room Air Quality Sensors

805QS Pressure Switch-Transmitter

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Duct Air Quality Sensors

Snifter ATEX22 VERSION. User Manual. Distributor

Vapor-logic3 Humidifier Control System

LC2200 Level Controller Installation and Maintenance Instructions

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

SAFETY INFORMATION AND WARNINGS

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Safety, Installation, and Operation Manual

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

W43A Humidistat. Features and Benefits

TrueAlarm Analog Sensing

Cambridge Engineering, Inc. 24 S-Series Technical Manual

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Carbon Monoxide Transmitter

TrueAlarm Analog Sensing

ETAF Series VDC Fan output LCD Fan Coil Thermostat

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

HTO-45 HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL

F AN-ASPIRATED RADIATION SHIELD

T-32-TS Touchscreen Thermostat. Installation Manual

for relative humidity and temperature with calibration certificates

A99B Series Temperature Sensors

DMFPM-2R MULTIFUNCTIONAL

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

VH7200 Humidistat Series For Humidification & Dehumidification Control For Commercial HVAC Applications (Issue Date January 22, R7)

SE7200 Series Installation Guide

DAWN Electronics, Inc.

for relative humidity and temperature

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Sintrol Snifter A1+ Manual. Version 1.2.2

HVAC Sensors Catalogue

Two-Channel Gas Controller

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

F AN-ASPIRATED RADIATION SHIELD

GCS Multipoint Carbon Dioxide Gas Concentration Sampler

Sensor Selection Guide. Sensing for Building Applications

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

Transcription:

RH & T Sensors & Humidistats RH-DT Duct Mount RH & T Sensors Description RH-DT Duct Mount RH & T Sensors The RH-DT Duct Mounted Humidity and Temperature Sensors offer the latest technology for high accuracy RH measurement. Units can be ordered with an optional direct resistive temperature output (where this option is required, the type of temperature element MUST be specified at the time of ordering). The RH-DT01 is also available with additional outputs for enthalpy and dewpoint (RH-DT01-EN). Non-standard temperature output ranges can be specified at time of order.

Features High stability and reliability Built-in circuitry diagnostics ±2% and ±3% Accuracy versions 4-20mA or 0-10Vdc outputs (link selectable) Direct thermistor temperature options available Specification RH accuracy: Temp. accuracy: RH element long term stability: Ambient range: Power supply: RH-DT01 ±2% (10 to 90%RH) RH-DT02 ±3% (20 to 80%RH) ±0.3 C <0.5% RH p.a. 10 to +50 C 4-20mA 20-35Vdc for 500Ω loop resistance 0-10Vdc 17 to 34Vdc, 14 to 26Vac (4.7kΩ min.) Standard 4-20mA or 0-10Vdc RH & temperature Output: Output ranges: Humidity 0 to 100% Temperature 20 to +50 C as standard,others available on request Protection: Dimensions: Weight: Technical Overview IP65 Housing 57 x 90mm diameter Probe 210 x 19mm diameter 220g The RH-DT duct mounted humidity & temperature sensors offer the latest technology for high accuracy RH measurement. Units can be ordered with an optional direct resistive temperature output (where this option is required, the type of temperature element MUST be specified at the time of ordering). The RH-DT01 is also available with additional outputs for enthalpy and dewpoint (RH-DT01-EN). Nonstandard temperature output ranges can be specified at time of order.

Installation 1. Antistatic precautions must be observed when handling these sensors. The PCB contains circuitry that can be damaged by static discharge. Transmitters should only be fitted to a system after airflow calibration has been carried out and preferably following full fan running of at least several days, in order that the main contaminants have been removed from the stagnant system. 2. Select a location in the duct where dust & contaminants are at a minimum (i.e. after filters etc.) and which will give a representative sample of the prevailing air condition. 3. If the sensor is to be mounted outside, it is recommended that the unit be mounted with the cable entry at the bottom. If the cable is fed from above then into the cable gland at the bottom, it is recommended that a rain loop be placed in the cable before entry into the sensor. 4. Drill two holes at 85mm centres, fix the IP65 housing to the duct with appropriate screws. Making sure to align the holes in the probe so they point into the air flow. The housing is designed to make it easy for an electric screwdriver to be used if desired. 5. Remove the front cover by twisting the lid and separating from the main body. 6. Feed the cable through the waterproof gland and terminate the cores at the terminal block. Leaving some slack inside the unit, tighten the cable gland onto the cable to ensure water tightness. 7. Replace the lid after the electrical connections have been made.

RH & T Sensors & Humidistats RH-OS Outside RH & T Sensors Description RH-OS Outside RH & T Sensors The RH-OS Outside Mounted Humidity and Temperature Sensors offer the latest technology for high accuracy RH measurement. Units can be ordered with an optional direct resistive temperature output (where this option is required, the type of temperature element MUST be specified at the time of ordering). The RH-OS01 is also available with additional outputs for enthalpy and dewpoint (RH-OS01-EN). Non-standard temperature output ranges can be specified at time of order. Features Radiation shield High stability and reliability Built-in circuitry diagnostics ±2% and ±3% Accuracy versions 4-20mA or 0-10Vdc outputs (link selectable) Direct thermistor temperature options available

Specification RH accuracy: RH-OS01 ±2% (10 to 90%RH) RH-OS02 ±3% (20 to 80%RH) ±0.3 C Temp. accuracy: RH element long term stability: < 0.5% RH p.a. Ambient range: 10 to +50 C Power supply: 4-20mA 20-35Vdc for 500Ω loop resistance Output: 0-10Vdc 17 to 34Vdc, 14 to 26Vac (4.7kΩ min.) Standard 4-20mA or 0-10Vdc RH & temperature Output ranges: Humidity 0 to 100% Temperature 20 to +50 C as standard, others available on request Protection: IP65 Dimensions: Housing 57 x 90mm diameter Shield 200 x 118mm diameter Weight: 1.14kg Technical Overview The RH-OS outside mounted humidity & temperature sensors offer the latest technology for high accuracy RH measurement. The sensor is supplied with a radiation shield, this provides the necessary protection of solar radiation and precipitation. Units can be ordered with an optional direct resistive temperature output (where this option is required, the type of temperature element MUST be specified at the time of ordering). The RH-OS01 is also available with additional outputs for enthalpy and dewpoint (RH-OS01-EN). Non-standard temperature output ranges can be specified at time of order. Installation 1. Fix the radiation shield to a suitable mast using the U bolts supplied. 2. When mounting the sensor outside it is recommended that a rain loop be placed in the cable before entry into the sensor. 3. Remove the front cover by twisting the lid and separating from the main body. 4. Feed the cable through the waterproof gland and terminate the cores at the terminal block. Leaving some slack inside the unit, tighten the cable gland onto the cable to ensure water tightness. 5. Replace the lid after the electrical connections have been made. 6. Ensure that the supply voltage is within the specified tolerances. 7. Allow 3 minutes before checking functionality. 8. Allow 30 minutes before carrying out pre-commissioning checks. Note Standard units are factory set for 4-20mA outputs.

RH & T Sensors & Humidistats RH-SH-xD Duct Humidistats Description RH-SH-xD Duct Humidistats RH-SH Humidistats are designed for the on/off control of humidification and dehumidification equipment, or the initiation of alarms or override controls. High quality sensing elements ensure accurate measurement and switching differential. Features Suitable for swimming pool applications

Specification Case construction: ABS Operating range: 30-100% RH Differential (per stage): 4% RH Stage differential: 2 to 15% RH Switch rating: Duct 15(8)A @ 240Vac Room 5(0.2)A @ 250Vac Cable entry: 20mm gland PG11 thread (not supplied) Protection: RH-SH-xD IP65 RH-SH-1DE IP20 Dimensions: Housing 108 x 72 x 72mm Probe 19mm dia. x 225mm long Weight: 300g Technical Overview The RH-SD-1D range of humidistat s are designed for duct mounting for the ON/OFF control of humidification and dehumidification equipment, or the initiation of alarms or override controls. High quality sensing elements ensure accurate measurement and switching differential. Installation 1. The RH-SH-1D should only be installed by a competent, suitably trained technician, experienced in installation with hazardous voltages. (>50Vac & <1000Vac or >75Vdc & 1500Vdc) 2. Ensure that all power is disconnected before carrying out any work on the RH- SH-1D. 3. Select a location in the duct where dust & contaminants are at a minimum (i.e. after filters etc.) and which will give a representative sample of the prevailing air condition. 4. If the sensor is to be mounted outside, it is recommended that the unit be mounted with the cable entry at the bottom. If the cable is fed from above then into the cable gland at the bottom, it is recommended that a rain loop be placed in the cable before entry into the sensor. 5. Remove the front cover, and separate from the main body. 6. Feed the cable through the waterproof gland and terminate the cores at the terminal block. Leaving some slack inside the unit, tighten the cable gland onto the cable to ensure watertightness. 7. Replace the lid after the electrical connections have been made. Warning The measurement location of the humidity controller should be selected so that no water can condense on or in the device. This applies particularly for operation with voltage higher than 48V. Failure to comply with this can result in damage to the controller.

RH & T Sensors & Humidistats RH-SH-xR Room Humidistats Description RH-SH-xR Room Humidistats RH-SH Humidistats are designed for the on/off control of humidification and dehumidification equipment, or the initiation of alarms or override controls. High quality sensing elements ensure accurate measurement and switching differential. Features Single or 2-stage versions available Specification Case construction: ABS Operating range: 30-100% RH Differential (per stage): 4% RH Stage differential: 2 to 15% RH Switch rating: Duct 15(8)A @ 240Vac Room 5(0.2)A @ 250Vac

Cable entry: Protection: Dimensions: Weight: 20mm gland PG11 thread (not supplied) IP20 Housing 115 x 35 x 70mm 300g Technical Overview The RH-SH-xR range of humidistat s are designed for wall mounting for the ON/OFF control of humidification and dehumidification equipment, or the initiation of alarms or override controls. High quality sensing elements ensure accurate measurement and switching differential. Installation 1. The RH-SH-xR should only be installed by a competent, suitably trained technician, experienced in installation with hazardous voltages. (>50Vac & <1000Vac or >75Vdc & 1500Vdc) 2. Ensure that all power is disconnected before carrying out any work on the RH- SH-xR. 3. Select a location in the occupied space where contaminants are at a minimum, and which will give a representative sample of the prevailing condition. 4. Undo the tamperproof screw at the bottom of the housing and gently pull the front panel from the base. 5. Using the base as a template mark the hole centres and fix to the wall with suitable screws. 6. Feed cable through the knockout in the base of the housing and terminate the cores at the terminal block, leaving some slack inside the unit. 7. Replace the housing to the base plate, and fit the tamperproof screw at the bottom of the base plate. Warning The measurement location of the humidity controller should be selected so that no water can condense on or in the device. This applies particularly for operation with voltage higher than 48V. Failure to comply with this can result in damage to the controller.

RH & T Sensors & Humidistats RH-SP Space Mount RH & T Sensors Description RH-SP Space Mount RH & T Sensors The RH-SP Space Mounted Humidity and Temperature Sensors offer the latest technology for high accuracy RH measurement. Units can be ordered with an optional integral LCD display for temperature and RH. The RH-SP01 is also available with additional outputs for enthalpy and dewpoint (RH-SP01-EN). Non-standard temperature output ranges can be specified at time of order. Features High stability and reliability Two part terminals for ease of connection Built-in circuitry diagnostics Three line fully configurable LCD display option

Specification RH accuracy: RH-SP01 ±2% (10 to 90%RH) RH-SP02 ±3% (20 to 80%RH) ±0.3 C Temp. accuracy: RH element long term stability: < 0.5% RH p.a. Ambient range: 10 to +50 C Power supply: 4-20mA 20-35Vdc for 500Ω loop resistance Output: 0-10Vdc 17 to 34Vdc, 14 to 26Vac (4.7kΩ min.) Standard 4-20mA or 0-10Vdc RH & temperature Output ranges: Humidity 0 to 100% Temperature 0 to 40 C as standard, others available on request Protection: IP20 Dimensions: 85 x 85 x 27mm Weight: 100g Technical Overview The RH-SP space mounted humidity & temperature sensors offer the latest technology for high accuracy RH measurement. The RH-SP01 is also available with additional outputs for enthalpy and dewpoint (RH-SP01-EN). Non-standard temperature output ranges can be specified at time of order. Installation Antistatic precautions must be observed when handling these sensors. The PCB contains circuitry that can be damaged by static discharge. 1. Select a location on a wall of the controlled space which will give a representative sample of the prevailing room condition. Avoid sitting the sensor in direct sunlight. 2. Undo the tamperproof screw at the bottom of the housing and gently pull the front panel from the base. 3. Using the base as a template mark the hole centres and fix to the wall using suitable screws. Alternatively the base plate can be mounted onto a conduit box or a standard recess back box. 4. Feed the cable through the 22mm knockout in the housing base and terminate as required. 5. Set jumpers as required. 5. Leaving some slack inside the housing replace the front panel to the base plate. 6. Fit the tamperproof screw (if required) through the lug at the bottom of the base plate. 7. Ensure that the supply voltage is within the specified tolerances. 8. Allow 3 minutes before checking functionality. 10. Allow 30 minutes before carrying out pre-commissioning checks. Note: Standard units are factory set for 4-20mA outputs.

RH & T Sensors & Humidistats RH-WL Wall Mount RH & T Sensors Description RH-WL Wall Mount RH & T Sensors The RH-WL Wall Mounted Humidity and Temperature Sensors offer the latest technology for high accuracy RH measurement. Units can be ordered with an optional direct resistive temperature output (where this option is required, the type of temperature element MUST be specified at the time of ordering). The RH-WL01 is also available with additional outputs for enthalpy and dewpoint (RH-WL01-EN). Non-standard temperature output ranges can be specified at time of order.

Features High stability and reliability Built-in circuitry diagnostics ±2% and ±3% Accuracy versions 4-20mA or 0-10Vdc outputs (link selectable) Direct thermistor temperature options available Specification RH accuracy: RH-WL01 ±2% (10 to 90%RH) RH-WL02 ±3% (20 to 80%RH) Temp. accuracy: ±0.3 C RH element long term stability: < 0.5% RH p.a. Ambient range: 10 to +50 C Power supply: 4-20mA 20-35Vdc for 500Ω loop resistance Output: 0-10Vdc 17 to 34Vdc, 14 to 26Vac (4.7kΩ min.) Standard 4-20mA or 0-10Vdc RH & temperature Output ranges: Humidity 0 to 100% Temperature 20 to +50 C as standard, others available on request Protection: IP54 Dimensions: Housing 57 x 90mm diameter Probe 90 x 19mm diameter Weight: 180g Technical Overview The RH-WL wall mounted humidity & temperature sensors offer the latest technology for high accuracy RH measurement. Units can be ordered with an optional direct resistive temperature output (where this option is required, the type of temperature element MUST be specified at the time of ordering). The RH-WL01 is also available with additional outputs for enthalpy and dewpoint (RH-WL01-EN). Nonstandard temperature output ranges can be specified at time of order.

Installation Antistatic precautions must be observed when handling these sensors. The PCB contains circuitry that can be damaged by static discharge. 1. Select a location in the occupied space, or externally where contaminants are at a minimum, and which will give a representative sample of the prevailing room condition. 2. If the sensor is to be mounted outside, it is recommended that the unit be mounted with the cable entry at the bottom. If the cable is fed from above then into the cable gland at the bottom, it is recommended that a rain loop be placed in the cable before entry into the sensor. 3. Drill two holes at 85mm centres, fix the IP65 housing to the wall with appropriate screws. The housing is designed to make it easy for an electric screwdriver to be used if desired. 4. Remove the front cover by twisting the lid and separating from the main body. 5. Feed the cable through the waterproof gland and terminate the cores at the terminal block. Leaving some slack inside the unit, tighten the cable gland onto the cable to ensure water tightness. 6. Replace the lid after the electrical connections have been made. 7. Ensure that the supply voltage is within the specified tolerances. 8. Allow 3 minutes before checking functionality. 9. Allow 30 minutes before carrying out pre-commissioning checks. Note: Standard units are factory set for 4-20Ma

RH & T Sensors & Humidistats RH-1000 Space RH & T - New Space Housing Description RH-1000 Space RH & T - New Space Housing Completely revised for the new 1000 series space housing, and using the latest high accuracy RH & T element, the new RH-1000 offers new options such as setpoint adjustment, momentary switch and fan speed selection, together with a multi-line backlit LCD display. A 0-10Vdc override status input option is also available, allowing occupancy indication on the display. 0-10Vdc or 4-20mA (loop or externally powered) outputs for temperature and RH are available as standard, with optional 0-5Vdc. A custom output range for temperature can be requested, between 0 C and +50 C. A directly connected passive thermistor temperature output is also available, as an alternative to the standard active temperature output. Features Designed to be aesthetically pleasing Blends into the fabric of any building Developed using customer feedback and involvement Specification Active Outputs: Voltage 0-10Vdc @ 4k7Ω min, 0-5Vdc @ 4k7Ω min (optional) Current 4-20mA @ 250Ω min

Optional Passive Outputs: Thermistor Any thermistor type* Setpoint 2-wire 1kΩ to 11kΩ, linear Override VFC Fan Speed 3 position Resistive, 5 position Resistive Output Ranges: RH 0-100% Temperature 0 C to +40 C as standard (others available on request: Range of 0 C and +50 C) Power Supply: 0-10Vdc 12-26Vac or 16-26Vdc @ 60mA max 4-20mA 20-26Vdc only @ 70mA max 4-20mA 20-26Vdc only @ 70mA max Temp. Accuracies: ±0.5 C (between +20 C and +40 C) Ambient: Temperature 0 C to 50 C RH 0 to 95% RH, non-condensing Housing material: ABS (flame retardant) Dimensions: 115 x 85 x 28mm Weight: 180g Technical Overview The RH-1000 uses the latest high accuracy RH & T element, and offers options such as set point adjust, momentary switch and fan speed selection, together with a multiline backlit LCD display. A 0-10Vdc override status input option is also available, allowing occupancy indication on the display. 0-10Vdc or 4-20mA (loop or externally powered) outputs for temperature and RH are available as standard, with optional 0-5Vdc. A custom output range for temperature can be requested, between 0 C and +50 C. A directly connected passive thermistor temperature output is also available, as an alternative to the standard active temperature output. Installation 1. Select a location on a wall of the controlled space which will give a representative sample of the prevailing room condition. Avoid sitting the sensor in direct sunlight, on an outside wall or near heat sources. An idea mounting height is 1.5m from the floor. 2. Undo the tamperproof screw at the bottom of the housing. 3. To remove the front panel from the base, twist a screwdriver as below and pull gently the front panel from the base. 4. Using the base as a template mark the hole centres and fix to the wall with suitable screws. Alternatively the base plate can be mounted on to a conduit box or standard recessed back box. The base plate is suitable for EU & North America fixings. 5. Feed cable through the hole in the base plate of the housing and terminate the cores at the terminal block as required. Leaving some slack inside the unit. 6. Replace the housing to the base plate. 7. Fit the tamperproof screw (if required) through the lug at the bottom of the base plate.