HEAT TROL ELITE SERIES HWE-Single Stage, HWE-MOV, HWE-Mulit Stage Hot Water Reset Control for Light Commercial and Residential Applications Provides q

Similar documents
INSTALLATION AND OPERATION INSTRUCTIONS RESET CONTROLS FOR STEAM HEATING SYSTEMS

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

INSTALLATION/OPERATING INSTRUCTIONS SEQUENCING PANELS

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

- Essay Control Functions and Benefits

- Data Brochure Boiler Control 274

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

New Versa IC Platform

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

SYX660 Commissioning Guide V Page 1 of 55

Digital Precise Air Control - DPAC

- Data Brochure Steam Control 279

HEAT-TIMER CORP. 20 NEW DUTCH LANE FAIRFIELD, NEW JERSEY TEL. (973) FAX (973) Model MPC OUTPUT LED'S OUTPUT RELAYS

Job Name Control Systems Description Date

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Service Manual Models:

OJ Waterline control system

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

Hydronic & HVAC Control Systems

B-40/B-41 Modulating Temperature Controller

Better Design, Better Control, Better Systems.

DAY/TIME Button: Selects hour, minute and day setting.

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

HVAC Controls Upgrades: Requirement Details ( )

Service Manual Models:

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Feature Summary. I. System

Service Manual. w/con X US Interface Models: WARNING

THERMOSTATS 126. MECHANICAL THERMOSTATS 1C20 / 1C21 / 1C26 / 1E30 / 1E56 / 1F56... Wiring Diagrams / Configuration

Service Manual. w/con X US Interface Models: Series: & WARNING

HEAT PUMP PROGRAMMABLE THERMOSTAT

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic

Service Manual Models:

prestige Control Application Supplement - Type 5 MCBA WARNING

Service Manual. w/con X US Interface Models: Beginning with Serial # WARNING

prestige Control Application Supplement - TriMax

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION

Lyric T6 & T6R Smart Thermostat

prestige Control Application Supplement WARNING

HVAC Controls Upgrades: Requirement Details ( )

DHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override

Programmable Load Controller USER S GUIDE

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

OPTIMUM APPLIED SYSTEMS,

Smart Temp. Model

INSTALLATION/OPERATING INSTRUCTIONS HEAT-TROL Elite Series. HWE-Motorized Valve

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

DAY/TIME Button: Selects hour, minute and day setting.

prestige Control Application Supplement - Type 5 MCBA WARNING

Installation and Advanced Programming Instructions. HP8211-1RJ and HP8321-1RJ Heat Pump Thermostats

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Installation & Operation Manual

- Data Brochure D 260. Boiler Control /09

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

Service Manual Models: Series 100 & 101

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road

Heating Control Danfoss Link & Connect Thermostats

- Data Brochure Boiler Control 264e

T6984 A,D,E Electronic Floating Control Thermostats

HWE-SS DIGI-El i t e Hydronic Single-Stage Boiler Control

Document # R01

Wireless sensor transmitters should be installed within 200 to 500 feet of the RC2100 Controller.

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

Service Manual Models: 1.0, 1.3, and 1.5

WLM3 the 3 rd generation of the OJ Waterline TM Control Systems. Industry leading intelligence, control SLIDE OJ Electronics

Service Manual Models:

WWSD. Power. DHW Demand. Maximum. Supply. Minimum Boiler DHW. Zone 1 / Cooling. Pump / Vlv. System Pump. UnOccupied. of full output NRTL/C LR 58223

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

- Data Brochure Boiler Control 268

Set & $ave. Model Programmable Thermostat. installation and operation manual

WARNING Important Safety Information

Project Name: Location: Engineer: Contractor: I. GENERAL

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling

Service Manual Models: 1.0, 1.3, and 1.5

DX-9100 Applications from Engineering Services

CONTENTS. Installation Guide. VT7200 Series

4 Wiring Brochure Wiring and

AirTrak. Digital Control System. User Manual. Touchscreen Systems

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Programmable Thermostat

prestige Control Application Supplement - ACVMax

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

Product Manual SZ1022/SZ1031/SZ1035/

prestige Control Application Supplement - TriMax

- Data Brochure Universal Reset Module 423

Programmable Load Management Thermostat

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

SYX66x Commissioning Guide V Page 1 of 61

Control Application. Supplement - ACVMax

HIGH EFFICIENCY COMMERCIAL BOILERS

1F Day 5/1/1 Day Non-Programmable. W/ Economizer Max. Stage Heat/Cool 1/1 1/2 2/2 2/3 3/1 3/2 4/2 4/3

HIGH EFFICIENCY COMMERCIAL BOILERS. Thermal Efficiency RIDE THE LOCHINVAR WAVE. Registered under U.S. Patent #9,746,176

Product Manual SZ2161. Description The SZ2161 is a microprocessor-based controller designed for water source heat pump plant control applications.

Transcription:

SIGNAL REPEATER RC2100 WI-CON Wireless Heating Control for Steam and Hot Water Boilers No sensor wiring required Intelligent sensing algorithm saves energy Low limit control and alarm alert operator of problems Uses spread spectrum wireless technology to provide control in multi-tenant steam or hot water heating applications Cycles boiler based on wireless outdoor air sensor value and the averaged input of up to 12 wireless indoor space sensors Wireless outdoor air sensor can be installed without penetrating the building, allowing sensor location to be optimized Wireless indoor sensors can be easily relocated for fine tuning and balancing of system Two temperature setpoints (day/night) Individual sensors can be selected to be included or excluded in the averaging calculation Adjustable time delay for control output Manual/auto system switch Built-in real time clock Selectable external clock input Optional wireless clock/ems interface Low battery and lost sensor alarms Space temperature low limit alarm and control output One or more signal repeaters can be added to system if longer signal is desired WIRELESS RC2100 PRICING RC-2100* $4,094.00 Additional Indoor Space Sensor $280.00 (each) Signal Repeater RR1552A $1,200.00 (each) *Includes the control, 1 outdoor sensor and 4 indoor space sensors INDOOR SPACE SENSOR OUTDOOR AIR SENSOR 130

HEAT TROL ELITE SERIES HWE-Single Stage, HWE-MOV, HWE-Mulit Stage Hot Water Reset Control for Light Commercial and Residential Applications Provides quick and accurate system status at the press of a button Indicates pump and boiler status at a glance 1 / 2 inch LED Display flashes to indicate sensor problems Accepts an optional thermostat or switch signal to control system Provides domestic hot water priority Monitors boiler loop temperature Temperatures displayed in 1 degree increments Adjustable outdoor system start point (can be disabled) Control settings are stored if power is lost Dry contact for remote enable/disable Adjustable minimum water temperature in HWE-Single Stage and HWE Multi Stage models Adjustable maximum water temperature adjustment for HWE-MOV HEAT-TROL PRICING HWE Multi Stage* $1,026.00 HWE MOV* $678.00 HWE Single Stage* $594.00 *Includes sensors 131 1029-37 W. Adams St., Chicago, IL 60607 Phone: (312) 733-1033 www.mid-lakes.com Toll Free: 888-733-2700 Fax: (312) 733-1721

EPU-CH PRICING Heat Timer EPU-CH Control* $3,474.00 *Includes sensors EPU-CH Outdoor/Indoor Heating Controls for Steam Boilers Effectively regulates ambient indoor temperatures according to outdoor temperatures by automatically cycling boiler operation Runs on cycle concept, meaning that as outdoor temperatures fall, the heating system runs longer keeping the ambient indoor temperatures constant A reliable, easily installed weatherhead sensor monitors outdoor temperature and can be run up to 500 from the panel A heating system sensor to signal the panel that heat has been circulated to all parts of the building. This sensor is strapped onto a system return pipe and can be run up to 500 from the panel Time clock to provide three different heat levels: Day or normal heat levels for when the building is occupied and active Night or save heat levels for when the building is empty or inactive Morning warm up to quickly return the building to comfortable temperatures after the night or save period Separate day and night adjustable outdoor temperature cutoff set points Separate day and night heat adjustments Easy to read lights show what the status of the panel is at all times Thermal lockout prevents a new cycle from starting if there is sufficient heat circulating in the building Lights indicate heating system sensor status Controls follow the weather: (see chart) The chart shows the approximate number of minutes of heat per hour after heat has been established. C on the chart refers to continuous operation. The standard cycle is one hour. However, 30 minute cycles are available on special order. If you use a 30 minute cycle, divide all figures in the chart by half. RUN TIME IN MINUTES BASED ON A 60 MIN CYCLE Outdoor Temperature Heat Adjustment -20-15 -10-5 0 5 10 15 20 25 30 35 40 45 50 A 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 B 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 C 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 D 46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 E 50 48 46 44 42 40 38 36 34 32 30 28 26 24 22 F C 52 50 48 46 44 42 40 38 36 34 32 30 28 26 G C C C 52 50 48 46 44 42 40 38 36 34 32 30 H C C C C C 52 50 48 46 44 42 40 38 36 34 I C C C C C C C 52 50 48 46 44 42 40 38 J C C C C C C C C C 52 50 48 46 44 42 132 C = constant run

MPC PLATINUM Cycling and Sequencing Controls for Steam Heating Systems Microprocessor based control to manage a steam boiler or a two way steam valve in steam heating applications based on system temperature and outdoor temperature Designed to utilize either a steam boiler or district steam Multiple day (normal) and night (save) schedules to reduce steam consumption Built in 7-day programmable save mode with 4 on settings and 4 off settings per day to customize operation Boost and vari-boost to bring building quickly to comfortable temperatures after night (save) period Vari-boost with early shut down allows office buildings to switch to night (save) mode earlier than scheduled, taking into consideration residual heat and outdoor temps Output relay and multiple auxiliary outputs Adaptable to energy management systems Digital display for all system settings Settings are stored and will not be lost if power is lost Optional remote communication add-on with modem or internet connection package Use existing sensors and/or wireless sensors Connect as many as 64 sensors to the panel Thermal lockout helps eliminate short cycling Day (normal) and night (save) modes Built in prove and system relay (combustion air and end switch) connections Manual shift allows for a temporary override Fast cycle for troubleshooting allows control to cycle on seconds rather than minutes Can connect to a Multi Mod or SEQ sequencing control Bypass allows installers and contractors to test and override the control settings when needed MPC PRICING MPC Platinum* $4,798.00 *Includes strap-on sensors and relays 133 1029-37 W. Adams St., Chicago, IL 60607 Phone: (312) 733-1033 www.mid-lakes.com Toll Free: 888-733-2700 Fax: (312) 733-1721

HWR PLATINUM SERIES Reset and Sequencing Controls for Hydronic Heating Systems HWR Platinum To control a single boiler or motorized valve operating with either a 2,3 or 4 way valve or by direct ON/OFF boiler action Adjustable outdoor temperature cutoff Multiple setback schedules Optimum start/stop Adjustable reset ratios Digital display Auxiliary clock HWR-Q Platinum To sequence up to 8 boiler stages by direct boiler action Adjustable outdoor temperature cutoff Multiple setback schedules Optimum start/stop Adjustable reset ratios Digital display Up to 8 stages of control 8 on/off boilers 4 low/hi fire boilers Automatic or manual rotation of lead stage Domestic hot water priority mode HWR CONTROL PRICING NOTES HWR-Q Platinum w/ SEQ12 To sequence up to 12 boiler stages utilizing model HWR-Q Platinum and output panel SEQ operating together by direct boiler action Adjustable outdoor temperature cutoff Multiple setback schedules Optimum start/stop Adjustable reset ratios Digital display Auxiliary clock Up to 12 stages of control 12 on/off boilers 6 lo/hi fire boilers Automatic, manual rotation of lead stage Domestic hot water priority mode Individual override switches (on/auto/off) 2 N.O. contacts per stage (2 N.O. & 1 N.C. on 8th stage) HWR-Q Platinum w/seq24 To sequence up to 24 boiler stages utilizing model HWR-Q Platinum and output panel SEQ operating together by direct boiler action Up to 24 stages of control 24 on/off boilers 12 lo/hi fire boilers All other specs same as HWR-Q Platinum w/seq12 HWR Platinum $3,372.00 Relays and sensors included HWR-Q Platinum $3,704.00 Relays and sensors included HWR-Q Platinum w/seq 12 $5,812.00 Stage Relays not included HWR-Q Platinum w/seq 24 $8,464.00 Stage Relays not included *Includes strap-on sensors 134

SEQ SEQUENCING SET POINT CONTROL For On/Off, 2 thru 12 Stage or Hi-Lo Units for Heating or Cooling Applications Sequences up to 12 stages for temperature, pressure or humidity systems Only one sensors Digital display of all system settings Automatic rotation among stages Built in multi stage control System output is active when any stage is active Remote shutdown and remote temperature set point control Built in outdoor reset with adjustable reset ratios SEQ PRICING Pricing SEQ-6 Sequencer* $1,618.00 SEQ-12 Sequencer* $2,108.00 *Does not include sensors or stage relays Lead Lag Control for up to 12 Stages 135 1029-37 W. Adams St., Chicago, IL 60607 Phone: (312) 733-1033 www.mid-lakes.com Toll Free: 888-733-2700 Fax: (312) 733-1721

Lead lag Control for up to 4 Stages MULTI MOD Modulating Set Point Control for Boilers and Chillers Sequences up to 4 fully modulating stages for temperature or pressure systems Controls 0-5, 0-10, 4-20 ma, or 135 modulating motors Only one sensor Digital display of all system settings Automatic rotation among stages Outdoor reset capability Connects to energy management systems Monitors stage status System output is active when any stage is active MULTI MOD PRICING Multi Mod* $5,442.00 *Does not include sensors 136