Cable Connectors For Armored Cable, Flexible Metal Conduit, Interlocked AC-38 Cables, NM and SE Cable

Similar documents
Speedlock AMC Connectors...KA1. Armored Cable Connectors...KB1-KB5 Metal Clad Cable Connectors...KB1-KB5 Flexible Metal Conduit Connectors...

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

The Star Teck Extreme STE/STEX Series Connectors

North American Cable Glands

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS INSTALLATION

The Next Generation of Greenfield Connectors. Our flex System is Your Solution for Electrical Runs

NELSON HEAT TRACING SYSTEMS

AGENDA. NEC Code-Making Panel 14. Report on Proposal Meeting. January 16-21, Hilton Head, SC

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

LED Flex Tube Assembly Guide

NHR-25 Feed Hopper with Agitator

NELSON HEAT TRACING SYSTEMS

FRP HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL FRP.IOM.R1

The Next Generation of Greenfield Connectors. Our flex System is Your Solution for Electrical Runs

NELSON HEAT TRACING SYSTEMS

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

ELECTRICAL SUPPLIES NATIONAL REFRIGERATION PRODUCTS WIRE NUTS HEAT SHRINK TUBING CABLE STAPLES CABLE MARKERS

NELSON HEAT TRACING SYSTEMS

Report on Proposals June 2013 NFPA 70

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

Band Heaters. Rectangular Band Heaters, Strip, Ring and Flat Heaters. Contact Accessories, Connection Boxes, Clamping Devices

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

NELSON HEAT TRACING SYSTEMS ALT-BC STANDARD POWER CONNECTION KIT

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

AFC Cable Systems: the Cable Industry Leader for Over 80 Years

Michigan Chapter IAEI Annual Meeting Ann Arbor, Michigan Code Panel Questions December 5 th and 6 th, 2013

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Second Revision No. 601 NFPA [ Section No [Excluding

1. Building wires and cables rated 600 V and less. 2. Connectors, splices, and terminations rated 600 V and less.

SECTION BASIC ELECTRICAL MATERIALS AND METHODS. A. This Section includes basic electrical materials and methods including:

C Electrical Connection Kit

SECTION ELECTRICAL GENERAL PROVISIONS

Chapter 1 General... 5

Helically wound resistance wire coil made

Piggyback Mechanical Float Switch. Piggyback Vertical Mechanical Float Switch. Piggyback Diaphragm Switch. Accessories

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

EDS Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

SN Series - Safety Shower Heaters Tankless Water Heating Solutions

Star Teck. Teck and Tray Cable Fittings. Table of Contents

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

SECTION HVAC Fans

Hose. Propane Hose. 1 X-treme Low Temp Bobtail Hose. Large Transfer Hose. Construction Tube: Cover: Reinforcement: Temp. Range:

MaxGard. Interconnection Systems. Durability. Performance. Safety

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

Circulation Heaters Selection Guidelines

Installation Instructions


ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

WATER SUPPLY HOOK-UP DISPLAY 0-WSH-1

Engineering Submittal Data PPRTH Patio Radiant Tube Heaters.

S1L Series: Metal Bottom

PHILADELPHIA REGIONAL PORT AUTHORITY VOLUME 2 SPECIFICATIONS FOR VEHICLE PROCESSING FACILITY NAVAL BUSINESS CENTER PHILADELPHIA PA.

SUPPLEMENTAL INSTRUCTION SHEET POL S2 POINT OBSTRUCTION LIGHT SINGLE WITH ALARM

ACCESSORIES GUIDE. RobroyEnclosures.com. Market-Leading Non-Metallic Enclosure Brands

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

Electricity Unit Notes. Agriculture Mechanics I

SDEC 2017 Questions, Group 1

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Thermal Stability Systems

temperature Controllers

Engine Block Heater Service Kits (Tank Type) 30RZ/33RZ/45RZ (CSG 649 Ford Powered) Standby Generator Sets

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

Please FAX or completed form to FWE. KFC Pre-Installation Check Sheet Pre-Installation Information. I t w i l l h e l p u s h e l p y o u!

Machining: Moderate to Extensive. Pattern Shop

Circulation Heaters Selection Guidelines

UL Electrical Equipment for Measurement, Control, and Laboratory Use; Part 1: General Requirements, Second Edition

CIRCUIT BREAKER UNIT ENCLOSURES 10,000/25,000 AMPERES INTERRUPTING CAPACITY. UPC Code. Catalog Number

Installation Instructions

Installation and Maintenance Instructions

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

READ ALL DIRECTIONS CAREFULLY BEFORE BEGINNING INSTALLATION

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

Technical Specification VFD

IMPORTANT INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS. Electric Wall Panel. Owner s Manual & Installation Instructions L

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

Barnes Oil Sensor Switch

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

READ ALL DIRECTIONS CAREFULLY BEFORE BEGINNING INSTALLATION

Moon Visions Lighting

INSTALLATION INSTRUCTIONS Model FH-2071-UM Enclosure

SECTION CUSTOM FABRICATED LABORATORY EQUIPMENT. This section specifies necropsy // dissecting tables // and // animalcage

ULTRA DYNAMIC HOSE PRODUCTS HOSE & TUBING CATALOG 2018 A DIVISION OF UBBER MPANY, INC. RUBBER COMPANY, INC RUBBER COMPANY, INC.

1-866-PENNERS

WATER HEATER SOLUTIONS

Heavy Industrial/Marine MaxGard

Installation Instructions

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

Transcription:

For Armored Cable, Flexible Metal Conduit, Interlocked AC-38 Cables, NM and SE Cable To ground and secure Armored Cable, Flexible Metal Conduit and Interlocked Metal Clad Cables to boxes and enclosures. To secure NM and SE Cables to boxes and enclosures. Available with insulated throats. All center stopped. Provided with locknuts. KC-50, KC-50T, KC-51 UL Listed for metal clad, armored cable, flexible metal conduit, sheathed cable, SE cable: E-11852 KC-75, KC-75T, KC-76 UL Listed for, armored cable, flexible metal conduit, sheathed cable, SE cable: E-11852 KC-100, KC-100T, KC-125, KC-125T UL Listed for flexible metal conduit: E-11853 KC-100, KC-100T, KC-125, KC-125T UL Listed for sheathed cable: E-23237 KC-100, KC-100T, KC-125, KC-125T UL Listed for SE cable: E-11858 KC-150 through KC-400 and KC-150T through KC-400T UL Listed for flexible metal conduit: E-11853 KC-500 and KC-500T: UL and CSA Listing is not applicable A B C Type KC-50 Type KC-76 Flex Millimeters Min. - Max. Type KC-350 Type KC-500 Type KC-100 Type KC-300 Insulated Throat 1/2 28.70 (1.13) 11.18 (0.44) 47.75 (1.88) 12.70-23.11 (0.50-0.91) KC-50 KC-50T 1/2 (3/4 KO) 28.70 (1.13) 11.18 (0.44) 47.75 (1.88) 12.70-23.88 (0.50-0.94) KC-51 3/4 30.23 (1.19) 12.70 (0.50) 54.10 (2.13) 22.35-27.69 (0.88-1.09) KC-75 KC-75T 3/4 (1 KO) 30.23 (1.19) 12.70 (0.50) 54.10 (2.13) 21.34-27.69 (0.84-1.09) KC-76 1 31.75 (1.25) 14.22 (0.56) 61.98 (2.44) 26.92-35.05 (1.06-1.38) KC-100 KC-75T 1-1/4 33.27 (1.31) 14.22 (0.56) 71.37 (2.81) 32.51-41.4 (1.28-1.63) KC-125 KC-125T 1-1/2 45.97 (1.81) 19.05 (0.75) 87.38 (3.44) 35.05-50.80 (1.38-2.00) KC-150 KC-150T 2 54.10 (2.13) 22.35 (0.88) 107.95 (4.25) 54.10-63.50 (2.13-2.50) KC-200 KC-200T 2-1/2 66.80 (2.63) 22.35 (0.88) 127.00 (5.00) 61.98-76.20 (2.44-3.00) KC-250 KC-250T 3 77.72 (3.06) 26.92 (1.06) 139.70 (5.50) 74.68-88.90 (2.94-3.50) KC-300 KC-300T 3-1/2 90.42 (3.56) 31.75 (1.25) 165.10 (6.50) 94.49-101.60 (3.72-4.00) KC-350 KC-350T 4 93.73 (3.69) 31.75 (1.25) 177.80 (7.00) 103.12-112.78 (4.06-4.44) KC-400 KC-400T 5 127.00 (5.00) 38.10 (1.50) 212.85 (8.38) 134.87-139.7 (5.31-5.50) KC-500 KC-500T 380

For Armored Cable and Flexible Metal Conduit Application To ground and secure Armored Cable and Flexible Metal Conduit to boxes and enclosures. Feature Male hub threads NPS Available with insulated throat. C-5 through C-8 UL Listed for armored cable: E-11852 C-8, 24-34 through 24-300 UL Listed for flexible metal conduit: E-11853 UL Listed flexible metal conduit fittings are suitable for use in Hazardous Location under NEC 501-4(b), Class I, Division 2, and suitable as a grounding means under NEC 350-5. CSA Certified for Armored Cable: 009795 Type C-5 End Stopped Type C-8 Type 24-125 Center Stopped Type 24-150 Type 24-300 Center Stopped Body Max. Width Flex. Insulated Throat 3/8 (1/2 KO) 14.22 (0.56) 11.18 (0.44) 28.70 (1.13) 12.70-14.99 (0.50-0.59) C-5 1/2 23.88 (0.94) 12.70 (0.50) 39.62 (1.56) 19.81-23.88 (0.78-0.94) C-8 C-8T 3/4 28.7 (1.13) 12.70 (0.50) 44.45 (1.75) 23.11-27.43 (0.91-1.08) 24-34 24-34T 1 30.23 (1.19) 14.22 (0.56) 55.63 (2.19) 32.51-36.58 (1.28-1.44) 24-100 24-100T 1-1/4 31.75 (1.25) 16.00 (0.63) 63.50 (2.50) 36.58-41.4 (1.44-1.63) 24-125 24-125T 1-1/2 47.75 (1.88) 17.53 (0.69) 66.80 (2.63) 41.40-47.75 (1.63-1.88) 24-150 24-150T 2 50.80 (2.00) 19.05 (0.75) 84.07 (3.31) 55.63-60.45 (2.19-2.38) 24-200 24-200T 2-1/2 52.32 (2.06) 23.88 (0.94) 103.12 (4.06) 68.58-74.93 (2.70-2.95) 24-250 24-250T 3 57.15 (2.25) 23.88 (0.94) 117.6 (4.63) 79.50-88.90 (3.13-3.50) 24-300 24-300T 381

Cable Connectors Two Screw Clamp and 90 Squeeze Connectors For Armored Cable and Flexible Metal Conduit Application: To ground and secure Armored Cable and Flexible Metal Conduit to boxes and enclosures. Male hubs - NPS. Provided with center stop. Available with insulated throats. Also suitable for NM and SE cable. (1203) UL Listed: E-11853 Type ACV-938 Type AC-150 Type AC-200 Type ACV-50 Type AC-125 Type AC-250 Type AC-400 Insulated Throat A B C Flex 3/8 (1/2 KO) 33.27 (1.31) 20.57 (0.81) 11.18 (0.44) 9.14-16.76 (0.36-0.66) ACV-938 ACV-938T 1/2 44.45 (1.75) 26.92 (1.06) 11.18 (0.44) 19.81-24.13 (0.78-0.95) ACV-50 ACV-50T 3/4 45.97 (1.81) 28.70 (1.13) 11.18 (0.44) 23.11-25.91 (0.91-1.02) ACV-75 ACV-75T 1 52.32 (2.06) 39.62 (1.56) 14.22 (0.56) 31.75-35.05 (1.25-1.38) AC-100 AC-100T 1-1/4 71.37 (2.81) 50.80 (2.00) 14.22 (0.56) 35.81-41.4 (1.41-1.63) AC-125 AC-125T 1-1/2 96.77 (3.81) 71.37 (2.81) 14.22 (0.56) 44.45-50.8 (1.75-2.00) AC-150 AC-150T 2 120.65 (4.75) 82.55 (3.25) 17.53 (0.69) 55.63-42.93 (2.19-1.69) AC-200 AC-200T 2-1/2 158.75 (6.25) 109.47 (4.31) 22.35 (0.88) 69.85-76.20 (2.75-3.00) AC-250 AC-250T 3 184.15 (7.25) 130.30 (5.13) 25.40 (1.00) 82.55-88.9 (3.25-3.50) AC-300 AC-300T 3-1/2 260.35 (10.25) 196.85 (7.75) 31.75 (1.25) 93.98-105.66 (3.70-4.16) AC-350 AC-350T 4 330.20 (13.00) 247.65 (9.75) 31.75 (1.25) 104.39-115.82 (4.11-4.56) AC-400 AC-400T 382

Squeeze Connector For Armored Cable and Flexible Metal Conduit Application: To ground and secure Armored Cable and Flexible Metal Conduit to boxes and enclosures. Male hubs - NPS. Provided with center stop. Available with insulated throats. Also suitable for NM and SE cable. (1203) UL Listed: E-11852 Type AC-38 led RMC and IMC to Flexible Metal Conduit Female hubs - NPT. Zinc plated UL Listed: E-11853 Type CB Type AC-50 3/8 (1/2 KO) 1/2 3/4 Body 35.05 (1.38) 49.28 (1.94) 54.10 (2.13) 11.18 (0.44) 11.18 (0.44) 12.70 (0.50) Max. Width 31.75 (1.25) 42.93 (1.69) 44.45 (1.75) Flex. 13.46-15.49 (0.53-0.61) 19.81-23.88 (0.78-0.94) 23.11-26.92 (0.91-1.06) AC-38 AC-50 AC-75 Insulated Throat AC-38T AC-50T AC-75T Trade Size 1/2 3/4 1 Max. Dia. Flex Range 38.1 (1.50) 44.5 (1.75) 47.8 (1.88) 31.8 (1.25) 38.1 (1.50) 47.8 (1.88) 19.81-23.88 (0.78-0.94) 23.11-27.43 (0.91-1.08) 14.99-36.58 (0.59-1.44) CB-50 CB-75 CB-100 383

Duplex Connector For Armored Cable Application: To ground and secure two Armored Cables to boxes and enclosures. Cable stop. UL Listed for armored cables 14/2 to 10/2. Zinc plated (1203) UL Listed: 11852 CSA Standard: C22.2 No. 18 Body Max. Width Type 25-38C 3/8 (1/2 KO) 26.92 (1.06) 11.18 (0.44) 39.62 (1.56) 5.59-13.46 (0.22-0.53) 25-38C 384

For Armored Cable To ground and secure armored cable to boxes and enclosures. Cable stop. UL Listed for armored cable.. UL Listed: E-11852 A B C Type C-15L Cable Front View 3/8 (1/2 KO) 14.22 (0.56) 12.70 (0.50) 35.05 (1.38) 9.65-16.00 (0.38-0.63) C-15L Type C1Z Body Max. Width Flex. 3/8 (1/2 KO) 14.22 (0.56) 10.41 (0.41) 25.40 (1.00) 10.67-16.00 (0.42-0.63) C-1Z 385

Aluminum Sheathed For Smooth and Corrugated ALS Cable NEC: To ground and secure Aluminum Sheathed Cable to boxes and enclosures. End stopped. Furnished with locknut. NEC Certifications and Compliances UL Listed: E-11852 Fed. Spec: W-F-406E K.O. Size Inches of Clamp of Type ALS-50-525 End Stopped Cable Range Dia. over Armor Width of Clamp Min. Max. 1/2 14.22 (0.56) 11.94 (0.47) 35.05 (1.38) 9.65 (0.38) 13.46 (0.53) ALS-50-525 386

For Non-Metallic Sheathed Cable Type C-11LS - to secure non-metallic sheathed cable to boxes and enclosures. Type 806 and Type 906 Series - to secure non-metallic sheathed cable, service entrance cable and flexible cords to boxes and enclosures. Available with insulated throats. UL Listed: E-11856 UL Listed for 806, 906Z, 907, 908, 909 for NM and SE Cables UL Listed: E-11858 UL Listed for 806, 906Z for SE Cable C-11L - UL Listed E23237 for NM Cable Fed. Spec: W-F-406E Type C-11LS Type 806 Type 908 Type 909 Clamp Min. Max. Width A B C Insulated Throat 1/2 4.83 (0.19) 16.00 (0.63) 14.22 (0.56) 11.18 (0.44) 35.05 (1.38) C-11LS C-11LST 3/4 9.40 (0.37) 21.34 (0.84) 21.34 (0.84) 17.53 (0.69) 11.18 (0.44) 45.97 (1.81) 806 806T 1 10.67 (0.42) 26.67 (1.05) 26.67 (1.05) 17.53 (0.69) 14.22 (0.56) 52.32 (2.06) 906Z 906T 1-1/4 19.05 (0.75) 34.04 (1.34) 34.04 (1.34) 20.57 (0.81) 14.22 (0.56) 61.98 (2.44) 907 907T 1-1/2 23.11 (0.91) 36.83 (1.45) 39.37 (1.55) 22.35 (0.88) 16.00 (0.63) 69.85 (2.75) 908 908T 2 35.31 (1.39) 51.56 (2.03) 51.56 (2.03) 23.88 (0.94) 19.05 (0.75) 85.85 (3.38) 909 909T Longer screw to accommodate extra flexible cables. Not CSA Certified. 387

For Non-Metallic Sheathed Flat Cable To secure non-metallic sheathed flat cable, SE/SEU flat cable, and other oval (flat) non-metallic cables to boxes and enclosures. 2-screw double clamp - open throat type. Furnished with locknut. UL Listed: E-11856 CSA Certified: 11584 Fed. Spec: W-F-406E SEU Cable Range (Braid Neoprene and PVC Jacketed) Type 806F Type 908F Type 909F Clamp Range A B C Min. Max. Width 3/4 3#10 to 3#6 17.53 (0.69) 11.18 (0.44) 45.97 (1.81) 8.38 (0.33) 20.83 (0.82) 20.83 (0.82) 806F 1 3#10 to 3#2 17.53 (0.69) 14.22 (0.56) 52.32 (2.06) 7.62 (0.30) 26.92 (1.06) 26.92 (1.06) 906F 1-1/4 3#3 to 3#1/0 20.57 (0.81) 14.22 (0.56) 61.98 (2.44) 12.70 (0.50) 34.29 (1.35) 34.29 (1.35) 907F 1-1/2 3#1/0 to 3#3/0 22.35 (0.88) 16.00 (0.63) 69.85 (2.75) 14.99 (0.59) 28.19 (1.11) 39.62 (1.56) 908F 2 3#2/0 to 3#4/0 23.88 (0.94) 19.05 (0.75) 85.85 (3.38) 19.56 (0.77) 28.96 (1.14) 45.21 (1.78) 909F Longer screw to accommodate extra flexible cables. Not CSA Certified. 388