Not Shown Pad Cover, 6" Case, Yellow, 8" Case, Grey, 8" Case, Black, 8" Case, Black, 9" Case, Black, 10"

Similar documents
KEEP FOR FUTURE REFERENCE POWER TILTER DC-VOLTAGE READ ALL INSTRUCTIONS AND WARNINGS BEFORE OPERATING THIS LIFTER

KEEP FOR FUTURE REFERENCE FLAT LIFTER 300 DC-VOLTAGE READ ALL INSTRUCTIONS AND WARNINGS BEFORE OPERATING THIS LIFTER

KEEP FOR FUTURE REFERENCE 1 SCFM NOMINAL AIRFLOW SINGLE VACUUM SYSTEM DC-VOLTAGE POWER SYSTEM WITH MANUAL VALVE

USER MANUAL 04-0_MOD-KH1204US_H9 Objecto.indb _MOD-KH1204US_H9 Objecto.indb /06/29 15:02: /06/29 15:02:46

INSTALLATION & OPERATING INSTRUCTIONS

ELECTRIC FLAT PANEL FIREPLACE HEATER

6L PRESSURE COOKER. Instruction Manual. Model: PLA1424

1715HD, 2015HD Instructions For Use Models: ,

Application Tooling Specification Sheet

ELECTRIC STOVE HEATER Models: FS2213B

USER MANUAL 03-0_MOD-KH1203US_H5_H5.indb _MOD-KH1203US_H5_H5.indb /11/08 21:28: /11/08 21:28:13

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

Qualification Procedures for making PE 3408 Extra High Molecular Weight Polyethylene Heat Fusion Joints

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

8 lb Lightweight Vacuum Model CK LW 13/1

GRANITE COMPOSITE SINK

INSTRUCTION MANUAL PRODUCT VIEW

GARAGE VAC OWNERS MANUAL READ BEFORE OPERATING YOUR SYSTEM

MODEL MC-UL592 MC-UL594 POWER SOURCE. 230V - 240V ~ 50 Hz MAX INPUT 1400 W 1500 W NOMINAL INPUT DIMENSIONS (W x L x H)

569, 570, 571, 572 Series

IMPORTANT SAFETY INSTRUCTIONS

569, 570, 571, 572 Series

V. (Versus ) Bare Floor Vacuum

Owner's Manual. Please read this document carefully before installing and/or using your vacuum cleaning system.

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

NO VENTING REQUIRED 120V AC;

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

Diamond Whirlpool/Air pool INSTALLATION & OPERATION INSTRUCTION

568X, 587X, 588X Series

Pocket Hardmount. Preventative Maintenance.

SM088 STEAM MOP INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: SM088 G-B-R

USER S GUIDE 1425 SERIES. 2 Consumer Service. 3 Safety Instructions. 4 Product View. 4 Assembly. 5-6 Operation. 6 Maintenance and Care

1425 Series U S E R S G U I D E. 2 Thanks / Consumer Services. Safety Instructions. Product View. Product Features. Assembly.

OPERATING INSTRUCTIONS

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

Wet/Dry Vacuum Kit

JUL 17 Rev C

OWNER S MANUAL ELECTRIC FIREPLACE INSERT. Model No.: WESTERN (EF42D-45D) WARNING CAUTION

INSTALLATION INSTRUCTIONS

Tornado Operations & Maintenance Manual

Owner s Manual CPU-1QD CPU-1 CPU-1T CPU-2 CPU-2T HEAVY DUTY UPRIGHT VACUUMS. Save These Instructions

green LITTLE 1400/1425 Series COMPACT DEEP CLEANER 2 Thanks / Consumer Services Safety Instructions Product View This Guide / Features

ZD-985 Desoldering Station

Wall Mount Electric Fireplace

OPERATING INSTRUCTIONS

Decon Scrubber Owner s Manual

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

π H-2268 SANITAIRE UPRIGHT VACUUM SAFETY uline.com

REVIVAL LITE VITREOUS CHINA REVERSE TRAP TOILET

Hydraulic Crimping Heads and

3/4 HP Model Trimmer Operating Instructions

Thermal Steel Care & Maintenance Guide

Thermal Electric Wine & Beverage Chiller Model: WC-2463W. Instruction Manual

(The chances are you re never going to read me) Owner s Manual HEAVY DUTY SHD-1T.

COBRA -300H EXTRACTOR

5 Maintenance. A November

Flat Wall Mounted / Free stand Electric Fireplace. Model Numbers: S OWNER S MANUAL. Wall Hanging Mode. Freestanding Mode AC 120V / 60HZ 1500W

Xaact Spot. Xaact Hot Spot

HP310-C EXTRACTOR 120V

Revision 3. April Owner s Manual. Serial Number Here. Date of Purchase

Tornado Operations & Maintenance Manual

Ultra Lightweight Household & Commercial Vacuums

MODEL COMPRESSOR SERVICE KIT For use on Midmark Power Air Oil-less Compressor Models P21, P22 & P32

Model: PS-2 ProSense II Item # OPERATION SERVICE PARTS CARE

Revision 2. October Owner s Manual. Serial Number Here. Date of Purchase

STAINLESS STEEL UNITS

WARNING: Product view. Cleaning fluid. Carry Handle. Power Button Formula & Clean Water Tank. Dirty Water Tank. Power Cord. Quick Release Cord Wrap

WET/DRY VACUUM Models PF51, PF53, PF55, PF57

OWNER S GUIDE NV500NZV2

Easy Vac BAGLESS VACUUM

SERVICING INFORMATION

LIMITED LIFETIME WARRANTY

INSTALLATION INSTRUCTIONS

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

Daily Cleaning Instructions: KL1Plus

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION

ADVANTAGE-100H-SC EXTRACTOR

Damp Locations Wall & Ceiling Mount BEFORE YOU BEGIN

USER'S GUIDE 6585 SERIES

Owner s Guide and Installation Manual

ROTARY TUMBLER LORTONE INSTRUCTIONS AND PARTS LIST. Model 3-1.5B. Model 45C. Model 33B Cyrus Way Mukilteo, WA (425)

PORTRAIT LITE VITREOUS CHINA REVERSE TRAP TOILET

R20SC, R20E & R20ENT. Owner s Manual

DELUXE ELECTRIC POWER BRUSH

π H-7147 SANITAIRE EON QUIET CLEAN VACUUM SAFETY uline.com

Instructions CH Chrome SS Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet. Tools Required.

DISCONTINUED. Widespread Lavatory Faucet TL170DD RENESSE. Contents. Installation and Owner s Manual. English Español Français

INSTALLATION INSTRUCTIONS

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual

MC-V Vacuum Cleaner. Specifications are subject to change without notice for further improvement.

FLOOR RAMMER. Throttle Type. Blows per Minute. (L) Lever Inches 609 mm

ACRYLIC CLAWFOOT TUB

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

A GUIDE TO LOOKING AFTER YOUR WINDOWS AND DOORS

Installation Guide. Pedicure Spa D K-163, K-1006, K-1011, K-1012

ELECTRIC FIREPLACE WITH MANTEL MODEL WS-Q-03 OWNERS MANUAL

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6

Transcription:

S O NSTRUCTONS Model LJ6VH Models N4000 N5000 N6000 Models N4300 N5300 N6300 Models N4950 N5450 N6450 Models N5450CS N5000CS Rev. 6.5 / 02-13 nstruction Sheet 32612AM NA 1. 90510 Handle, Metal 2. 90520AM Plunger Assembly, Metal (for LJ6VH, N4950, N5450, N5450CS, N6450) 90154AM Plunger Assembly, ABS (for N4000, N4300, N5000, N5300, N6000,N6300) 3. 49486T Vacuum Pad, 8" Dia., Flat (G0695) 49506T Vacuum Pad, 9" Dia., Flat (G0725) 49520T Vacuum Pad, 9" Dia., Concave (VPCS9) 49586T Vacuum Pad, 10" Dia., Concave (G0750) 4. 90500 Valve Block with Release Lever & Guard 5. 51506 Valve Guard 6. 60024 Air Filter 7. 10002 Screw, 1/4-20 x 1/2" 8. 61552 Check Ball 9. 61514 O-Ring 10. 10008 Screw, 10-32 x 3/8" 11. Red Line 12. 90151 Handle / Valve Assembly, ABS 13. 61151 Check Valve Retainer 14. 51100 Check Valve 15. Valve Release Lever 16. Release Tab 17. 90115 Handle, Vertical 18. 49416T Vacuum Pad, 6" Dia. (LJ6) 19. 10006 Screw, 10-32 x 5/16" Not Shown 29312 Pad Cover, 6" 29330 Case, Yellow, 8" 29335 Case, Grey, 8" 29334 Case, Black, 8" 29338 Case, Black, 9" 29342 Case, Black, 10" N4000 N5000 N5000CS N6000 LJ6VH N4300 N5300 N6300 N4950 N5450 N5450CS N6450 SPECFCATONS Product Description Hand cups use vacuum to lift and carry loads, as follows: A manual pump removes air from between the rubber pad and the contact surface; a red line on the pump's plunger serves as a vacuum indicator; a check valve allows the user to repump the cup without removing it from the contact surface; and a release mechanism allows the cup to disengage completely. Model Pad Nominal Dia. Max. Load Capacity* LJ6VH LJ6 6" [15 cm] 70 lbs [32 kg] N4000, N4300, N4950 G0695 8" [20 cm] 125 lbs [57 kg] N5000, N5300, N5450 G0725 9" [23 cm] 150 lbs [68 kg] N5450CS, N5000CS VPCS9 9" [23 cm] 150 lbs [68 kg] N6000, N6300, N6450 G0750 10" [25 cm] 175 lbs [79 kg] *Maximum Load Capacity includes a 3:1 safety factor and requires the following: attachment on clean, smooth, nonporous flat surfaces; a minimum vacuum level of 17½" Hg [-59 kpa]; and a friction coefficient of 1. This rating is based on tests of new hand cups attached to the upper, horizontal surface of static objects in ideal conditions. Many factors can reduce the capacity, including: lifting a load when the cup is attached to a vertical or inclined surface; or lifting a load that applies leverage to the cup. See www.powrgrip.com for more information. Load and Environmental Conditions Use the cup on clean, relatively smooth, nonporous surfaces, at temperatures from 10 to 120 Fahrenheit [-12 to 49 Celsius]. Moisture or contaminants can reduce the slip resistance of the cup. The red-line indicator may not perform reliably at elevations above 5000 feet [1524 meters]; see Service. OPERATON To Attach 1) Position the hand cup on the contact surface so the red line will be visible if it should appear while lifting the load. CAUTON: Test the cup for staining or deformation of load surfaces with light colors or soft coatings. 2) Pump the plunger until the cup attaches completely. When the red line is hidden, vacuum is sufficient for lifting. 3) Check the plunger frequently to make sure the cup remains securely attached. f the red line appears while lifting, set down the load immediately and pump the plunger until the red line is hidden again (see WARNNGS). To Release 1) Set the load on a secure support. 2) Pull one of the release tabs (on 6" [15 cm] cups) or press the valve release lever (on other cups) until the cup disengages completely. CAUTON: Remove the cup when not in use. MANTENANCE Service Since aging and wear reduce the capacity of the rubber pad, it should be replaced at least once every 2 years or whenever damage is discovered (see nspection). f the hand cup does not function normally, the cup face may be dirty or the cup may require service. First clean the cup face according to the directions to follow. f the condition persists, contact an authorized dealer or visit www.powrgrip.com for assistance. Cleaning 1) Remove the air filter from the cup face. 2) Use a clean sponge or lint-free cloth to apply soapy water or another mild cleanser to the cup face; see WARNNGS and www.powrgrip.com for more information. CAUTON: To prevent liquid from contaminating the pump, hold the cup face-down or cover the suction hole in the filter recess. 3) Wipe all residue from the cup face. 4) Allow the cup to dry and reinstall the air filter. nspection Examine and test the cup regularly to make sure it does not exhibit the following faults: cuts or damage to sealing edges of rubber pad. cracks or dents in handle or pump. reappearance of red line soon after attaching cup. sluggishness or dramatic changes in pump action. excessive glaze or stiffness of rubber pad. air filter missing from cup face. Correct any faults before using the cup (see Service). Storage Store the cup in clean, dry condition within its protective carrying case. WARNNGS Failure to observe WARNNGS could damage the hand cup or the load, or cause injury to the user. Do not use the cup to lift loads that exceed the Maximum Load Capacity or the effective capacity (see SPECFCATONS). Do not use the cup to support a person. Do not place the cup face against surfaces which could damage the sealing edges. Avoid conditions that could cause the cup to slip or to disengage prematurely, such as: contaminants, cuts or scratches in the cup face or contact surface; applying the cup to porous materials; or applying pressure against the cup edge. Do not use the cup to lift when the red line is visible. f the red line reappears frequently, discontinue use and see Service. Do not allow anything to interfere with free movement of the plunger while the cup is attached. Do not touch the release tabs (on 6" [15 cm] cups) or the valve release lever (on other cups) while lifting. Do not attach 10" [25 cm] diameter cups to thin, fragile materials. Do not use harsh chemicals (such as solvents or gasoline) or unauthorized rubber cleaners and conditioners to clean the cup. 908 West Main - P.O. Box 368 800.548.7341 406.628.8354 (fax) Laurel, MT 59044 U.S.A. 406.628.8231 www.powrgrip.com SYSTEM CE 9001 :2 008 T FC TON S S Products are manufactured under an SO 9001 quality management system R A

S Guide to Maintenance, Troubleshooting, and Repair N4000, N4100, N5000, N6000, N4000TS, N5000CS, N6000NBP ABS HANDLE HAND CUPS General Maintenance For maximum reliability, NSPECT THE HAND CUP REGULARLY: Make sure the air filter is in place; if not, discontinue use until the filter is replaced. Examine the plunger and handle for cracks or other damage. Examine the face of the vacuum pad for excessive glaze (a polished, glossy appearance) and for cuts or roughness on the sealing edges. Periodically test the cup for excessive leakage, sluggishness in plunger action or radical changes in the number of strokes needed to keep the red line hidden. f the cup does not function normally, review the Troubleshooting Guide (overleaf) to determine what corrective action is needed. THE ORGNAL & TRUSTED NAME N VACUUM LFTNG EQUPMENT To CLEAN THE VACUUM PAD, remove the air filter from the pad face. Use a clean sponge or lint-free cloth to apply soapy water or another mild cleanser to the cup face. Never use solvents or rubber conditioners as a cleaning agent (see WARNNGS). To prevent liquid from contaminating the pump during cleaning, hold the cup face-down or cover the suction inlet in the filter recess. For 8" [20 cm] pads, be careful not to dampen the felt strip at the pad s edge. Wipe all residue from the pad face and allow the cup to dry. Then reinstall the air filter. O 908 West Main - P.O. Box 368 Laurel, Montana 59044 U.S.A. 406.628.8231 (phone) 406.628.8354 (fax) 9001 SYSTEM CE R :2 008 T FC S Rev. 0.8/ 03-14 800.548.7341 www.wpg.com A TON S Products are manufactured under an SO 9001 quality management system Wood's Powr-Grip products are sold through authorized dealers. ABS Troubleshooter 1LTS nspecting and Testing the Cup for Leakage To NSPECT THE SEALNG EDGES of the vacuum pad for roughness or foreign material, slowly draw your finger along the entire length of the sealing edges. Examine the sealing edges for cuts by bending the edge of the pad face towards you to create a hump, turning the hand cup as necessary. f cuts or cracks are present in a sealing edge, a V-shaped gap will appear. Any pad that exhibits a gap or excessive roughness in a sealing edge must be replaced. To LEAK-TEST THE HAND CUP, attach it to a clean, smooth, scratch-free piece of glass or metal for approximately 2 hours. The red line on the plunger serves as a vacuum indicator: f the red line does not appear during the test period, the cup is usable; if the red line does appear, perform general maintenance and repeat the test. f the problem persists, check the Troubleshooting Guide (overleaf) to identify possible causes and appropriate corrective actions. f these measures do not restore the cup to normal performance, contact the Wood s Powr-Grip Customer Service department or an authorized dealer for assistance. Environmental conditions can affect product performance and longevity; consult the product instructions on www.wpg.com or contact a Technical Sales Representative for more information. Based on product information at time of publication. 32621

PARTS AND ASSEMBLY 1 90151 Handle / Release Valve Assembly 2 90154AM Plunger Assembly 90158AM Plunger Assembly, High Elevation (for N4100) 90524AM Plunger Assembly, with Audio Alarm (WBP) 3 49486T Vacuum Pad, 8" [20 cm] Dia., Flat (G0695) 49488T Vacuum Pad, 8" [20 cm] Dia., Textured Surface (G0695TS) 49506T Vacuum Pad, 9" [23 cm] Dia., Flat (G0725) 49520T Vacuum Pad, 9" [23 m] Dia., Concave (VPCS9) 49586T Vacuum Pad, 10" [25 cm] Dia., Concave (G0750) 4 61151 Check Valve Retainer 5 51100 Check Valve 6 60024 Air Filter 7 10002 Handle Screws (6) 8 Red Line 9 Valve Release Lever Not Shown 29330 8" [20 cm] Case 29335 8" [20 cm] Case, Grey 29338 9" [23 cm] Case 29342 10" [25 cm] Case 28502 Plunger Lube TROUBLESHOOTNG GUDE PROBLEM CAUSE CORRECTON Slow leakage Severe leakage Jammed or sluggish pump Pad slips when attached More than 10 strokes needed to apply Cuts on sealing edge Dirt or lint inside pump Dry pump Scratches inside handle (between midpoint and closed end) Release valve pad contamination Contaminated pad face Severe contamination Gouges or cuts on sealing edge Broken handle or release valve Dry pump Obstructed valve stem Severe contamination Contaminated load surface Contaminated pad face Excessive glaze or wear on pad face Any of the above Dirt or lubricant on check valve Replace vacuum pad. Wipe inside of handle with a soft cloth. Check for contamination on U-cup or button. Apply a light coating of plunger lube inside handle. Replace handle. Open release valve and blow valve pad clean with air hose. Clean vacuum pad. Clean plunger assembly and inside of handle. Replace vacuum pad. Replace handle / release valve assembly. Apply a light coating of plunger lube inside handle. Remove obstruction (through suction inlet behind air filter). Clean plunger assembly and inside of handle. Wipe surface clean. f necessary, wash and allow to dry. Clean vacuum pad. Replace vacuum pad (at least once every two years). Perform general maintenance. Remove, clean and reinstall plunger assembly, retainer and check valve as directed in Disassembly and Assembly sections (on facing page).

Disassembly Procedures Remove Plunger Assembly from Handle Grasp the head of the plunger assembly and pull it straight out from the handle. Be careful to keep the plunger assembly clean and free from contaminants. t is advisable to cover the plunger assembly with a clean, lint-free towel when it is not in the handle. Remove Handle from Vacuum Pad Remove the 6 handle screws, and separate the handle from the pad. Carefully remove the valve stem from the rubber nipple on the pad by gently pulling on the handle and twisting it back and forth. Remove Retainer and Check Valve from Handle Being careful not to scratch the inside of the handle, remove the retainer and check valve using a hooked scribe or similar tool. With a soft, lint-free cloth, carefully clean these parts, as well as the plunger assembly, paying particular attention to the U-cup and button. Wrap a small dowel or rod with a soft, lintfree cloth and gently wipe the inside of the handle, to make sure it is clean and dry (lubricant-free). Assembly Procedures nspect Handle and Reinstall Check Valve and Retainer Carefully examine the inside of the handle for scratches and contaminants, using a flashlight for illumination. Scratches between the mid-point and the closed end of the handle can cause leakage. Scratches near the open end of the handle rarely present a problem. Make sure that no lubricant remains inside the handle. Drop the check valve inside the handle so that it lays flat against the closed end. Using a dowel or other tool that will not scratch the sides of the handle, push the retainer all the way into the handle to hold the check valve securely in place. Attach Handle to Vacuum Pad Apply a light coating of plunger lube to the valve stem of the handle, and insert the valve stem into the pad nipple. Place the handle on the pad so its nipple fits through the large hole in the base plate near the closed end of the handle. Align the screw holes and reinstall the handle screws. Reinsert Plunger Assembly into Handle Apply lubricant all the way around the exposed surface of the U-cup, while being careful to keep lubricant off the button. Plunger lube is recommended and available in appropriate quantities by contacting Wood s Powr-Grip Customer Service. Do not use improper lubricants in the handle. While making certain the button, check valve and retainer remain free of lubricant, insert the U-cup end of the plunger assembly into the handle. Push the plunger assembly until it begins to tighten; then seat the plunger assembly with one strong, swift motion. Operate the plunger to spread the lubricant, thoroughly coating the outside of the U-cup by twisting the plunger as it moves. Now the cup is assembled and ready for testing.

WARNNGS Wood s Powr-Grip has taken great care to produce the most reliable vacuum-operated handling device available. Nevertheless, mistreatment or misuse may damage a hand cup or otherwise create conditions which could cause the hand cup to fail, resulting in an unexpected release. The following warnings are offered to help users avoid most potential hazards. Failure to observe WARNNGS could damage the cup or the load, or cause injury to the user. Do not use the cup with loads that exceed the load capacity. Do not use the cup to support a person. Do not place the pad face against surfaces which could damage the sealing edges. Avoid conditions that could cause the cup to slip or to disengage prematurely, such as: contaminants, cuts or scratches in the pad face or load surface; applying the cup to porous materials; or applying pressure against the pad edge. Do not use the cup to lift when the red line is visible. f the red line reappears frequently, discontinue use and follow the instructions for general maintenance and testing. Do not allow anything to interfere with free movement of the plunger while the cup is attached. This could prevent the red line from warning the user of vacuum loss. Do not touch the valve release lever while lifting. Do not attach 10" [25 cm] diameter cups (models N6000 and N6000NBP) to thin, fragile materials. Do not use harsh chemicals (such as solvents or gasoline) or unauthorized rubber cleaners and conditioners to clean the cup. See www.wpg.com for more information.