SETTING UP A VIRTUAL KEYPAD WITH A DSC POWERSERIES ALARM SYSTEM

Similar documents
SETTING UP DSC INTEGRATION THROUGH ENTRAPASS

How to define and integrate the Simplex Fire panel in EntraPass

GLOBAL. InstallatIon & operation manual

Ness acomms Install & User Manual

Ademco Vista Alarm Panel

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

Paradox Integration Module Settings Guide

Resolution Compatibles Flex GSM IGM is a GSM cellular device that provides

abode Web app Functionality

KT-100 Door Controller

BAT WIFI SKU: IPD-BAT--WIFI

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Supervisor Standard Edition

Installation Manual GalaXy G2 / G3 / GD. o Settings GalaXy o Linking with iprotect o Keymap

Configuration and Operation Manual for the Unipos

OnGuard 7.2 Resolved Issues

System Galaxy Quick Guide

Synergis Master Controller 2.2 Integration Guide for Assa Abloy IP Locks

Complete Security Solution

Honeywell Total Connect Remote Services

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

GSM RFID VOICE Alarm System

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

Laptop / PC Programming Manual

OJD ITB No Attachment E Duress Alarm Equipment Specifications

DIAMOND II. DARM Delayed Alarm Reporting/Masking. Manual Number AV Revision - A.1 September 3, 2004

WiFi GSM APP Smart Home Security System

IntesisBox BACnet/IP Server - Notifier ID3000 series

BAT LTE SKU: IPD-BAT-LTE

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

Cardax System Comparison

UNC100 Integra Manual

To activate the Net2 alarm integration software the correct check box must be ticked on the features tab in the Net2 server configuration utility.

Application Version: 2.0 and above Date Written: 03/09/2010. Copyrights , Global Security Devices, All Rights Reserved

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

Advisor Advanced Mobile Application User Manual

rvm4c Installation Guide Remote Video Module

BlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7.

User manual. KNXgal. version

Contents. Glossary

Digital MFC software V1.10

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

Grandstream Networks, Inc. GDS3710 Input/output Alarms Configuration Guide

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.

IndigoVision. GAI-Tronics Integration Module. Administrator's Guide

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

780 Keypad Demonstrator Module

Avigilon Control Center System Integration Guide

Monitoring Operator Guide. Access Control Manager Software Version

DSC PowerSeries NEO Quick Start Guide

Planning Elevator Relay Groups Programming Millenium for Windows Software

CBI-064. User Manual. Caddx to KNX-BUS Interface

PBI Manual. Paradox to KNX-BUS Interface

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad.

Complexity made simple

Moxa Proactive Monitoring User s Manual

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

NextGen Home Security. Quick Reference Guide

RMS/RPX Reader. User Manual

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide

System. For a better understanding of this product, please read this user manual thoroughly before using it.

BOSCH GV4 Alarm Panel

PC51O2-433NA v1.0 Installation Manual

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Access CONTROL. MANAGEMENT Software

E Programmble Smoke Detector Controller. Figure 1. Programmable Smoke Detector Kit

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

My Visonic SMS App User Guide

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules

System Introduction. 1.1 Specifications S E C T I O N 1

Contents. Programming Worksheets 22. Appendix A: Guidelines for Locating Smoke Detectors 27. Index 28

TR/TS40, TR/TS16, TR/TS60 Thermostat

Long Range Radio Alarm Transmitter

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

Simplex Panel Interface Guide

Configuring IndigoVision Control Center. Configuring IndigoVision Control Center

User s Information Guide R2A

SYSTEM ENHANCEMENT MODULE

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Roo232 User Guide. Revision 1.0. Copyright 2006 RoboDynamics Corp

GSM Emergency Alarm. User s Manual. For a better understanding of this porduct,please read this user manual thoroughly before using it.

Diagnostics and Monitoring System WEB Tool 2. User Manual

DS-K2600 Series. Access Controller. Quick Start Guide UD01216B-A

icontrol OpenHome Converge Panel Interface Module Installation Guide Congratulations on purchasing your Panel Interface module.

AIRPORTS. CARECALLER PowerfulSecuritySolutionsForSeriousSecurityNeeds

21-light Remote Annunciator. Owner s Manual

Model 4880 Status Output Display Module Manual

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

INSTALLATION INSTRUCTIONS and BASIC SYSTEM CONFIGURATION

CASS9000 Standalone FingerPrint Door Access System. User Manual

Synergis Master Controller 2.2 Integration Guide for Assa Abloy Aperio- Enabled Locks

S6 Titan Security System. Wi-Fi and 3G GSM

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

600 Range Dialer Installation Manual. Version 1.0

Tech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5)

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

SIMPLIFIED HOME SECURITY AND CONTROL

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

Transcription:

DN1902-0909 SETTING UP A VIRTUAL KEYPAD WITH A DSC POWERSERIES ALARM SYSTEM The purpose of this application note is to configure the EntraPass system to interface with the DSC PowerSeries tm alarm systems via the use of a virtual keypad. With EntraPass Version 4.02, you can view and use the virtual keypad to perform any commands available from a standard DSC keypad; commands such as arm, disarm and programming the alarm panel. For a card swipe disarming integration you would still need to use the traditional method of integration with alarm systems (using relays and inputs from a Kantech controller). Requirements: EntraPass Corporate Edition or EntraPass Global Edition (version 4.02 and above) installed A Corporate gateway for EntraPass Global Edition or Global Gateway with a dual gateway feature DSC PowerSeries tm alarm panel and an IT-100 module RS-232 Straight-through cable Serial port on EntraPass Corporate gateway computer Hardware Setup: To connect the IT-100 to the EntraPass system and the DSC PowerSeries tm alarm panel, follow the steps below: (For more information please refer to the DSC IT-100 manual) 1) To wire the IT-100 to the alarm panel: a. Power down the alarm panel b. Connect the IT-100 module using a 4-wire KEYBUS connection to the PowerSeries tm alarm panel. Connect the RED, BLK, YEL and GRN terminals to the KEYBUS terminals of the PowerSeries tm alarm panel. c. Power up the alarm panel. 2) To connect the IT-100 to EntraPass: a. Connect a RS-232 straight-through cable between the IT-100 serial port to the computer s serial port. A male/female RS-232 cable is needed and only the TX, RX and GND pins are used (Pins 2 2, Pin 3 3, Pin 5 5). 1 (450) 444-2030 Toll free: 1-888-222-1560 Fax: 1 (450) 444-2029 www.kantech.com 1

The IT-100 can be connected at a maximum of 98.4ft (30m) at 9600 baud rate from the EntraPass Corporate Gateway. EntraPass Setup: 1) To program the DSC Virtual Keypad, go to the Devices tab and select the Integrated Device button. a. In the Integrated Device tab, make sure the View component hierarchy button is not pressed. b. Press on the New button and in the English text box, name the device accordingly. c. In the Panel Type drown down list, select DSC PowerSeries IT-100. d. In the RS-232 tab select the communication port COM that the IT-100 is connected to. e. Save the configuration. 2) To change the name of the virtual keypad; go to the Devices tab and select the Integrated Component button. a. In the Integrated Component window, select the appropriate component in the Component drop down list. b. In the English textbox, name it accordingly. c. Save the configuration. 1 (450) 444-2030 Toll free: 1-888-222-1560 Fax: 1 (450) 444-2029 www.kantech.com 2

3) To view the status of the DSC Virtual Keypad, go to the Operation tab and select the Integrated Device button. a. Left click on the Integrated Device on the left. b. On right panel, select the DSC Virtual Keypad and right click on it with the mouse. c. Click on Full Status to view the communication status of the unit. If you do not get the same results as shown above; please verify that your EntraPass gateway is communicating with EntraPass and that your RS-232 cable is correctly inserted into the serial ports. For further troubleshooting, please contact technical support. 4) To view and use the DSC Virtual Keypad, go to the Operation tab and select the Integrated Device button. a. Left click on the Integrated Device on the left. b. On right panel, select the DSC Virtual Keypad and right click on it with the mouse. c. Select Virtual Keypad Using the mouse, you can click on any buttons on the Virtual Keypad as if you were using a standard keypad. You can also use the computer keyboard to simulate the button pressing. 1 (450) 444-2030 Toll free: 1-888-222-1560 Fax: 1 (450) 444-2029 www.kantech.com 3

5) To view a virtual keypad from a graphic, go to the Definition tab and select the Graphic button a. Choose the appropriate graphic from the Graphic drown down list. - If you do not have a graphic; you would need to create a new one. b. Click on the Click here to create, edit or modify a graphic button. c. Drag and drop the Panel component icon on the graphic screen d. Select the Keypad from the list box e. From the Keypad icon right click and select Default Double Click as Virtual Keypad f. Close the window by clicking on the X at the top. g. Save the graphic. 1 (450) 444-2030 Toll free: 1-888-222-1560 Fax: 1 (450) 444-2029 www.kantech.com 4

FUNCTIONS AVAILABLE WITH THE DSC VIRTUAL KEYPAD AND ENTRAPASS VERSION 4.02: Feature Arming via Keypad Disarming via Keypad Programming alarm panel Home arming Away arming Chime Reset Smoke Detector Fire Police Panic Zone status Language change Ready/Trouble status Time and date Arming Kantech reader Disarming Kantech reader Events from alarm panel Alarm pop ups Availability With EntraPass Version 4.02, you can view and use the virtual keypad to perform any commands available from a standard DSC keypad; commands such as arm, disarm and programming the alarm panel. Information furnished by Kantech is believed to be accurate and reliable. However, no responsibility is assumed by Kantech for its use, nor any infringements of other rights of third parties which may result from its use. No license is granted by implications or otherwise under any patent rights of Kantech. 1 (450) 444-2030 Toll free: 1-888-222-1560 Fax: 1 (450) 444-2029 www.kantech.com 5