R Series Remote Annunciators and Expander Installation and Operation Guide

Similar documents
R-Series Remote Annunciators and Expanders Installation and Operation Guide

RMS/RPX Reader. User Manual

KM300 Carbon Monoxide Detection System Installation Manual

TruVision Bullet IR Camera Pocket Guide

TruVision Bullet IR Camera Pocket Guide

FTP-1000 Touchpad/Display Installation Manual

KFP-CF Series Operation Manual

Installation Manual. Wiegand Interface Unit Four-State (WIU-4) North America T F Asia T F

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

SIGA-CC1 Single Input Signal Module Installation Sheet

ZP2 Series Operation Manual

Installation Instructions Model SSD-C-REM

1X-F Series Installation Manual

Remote Booster Power Supply Technical Reference Manual

ANNUNCIATOR FIXED MODULE

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

GE Security. Challenger V8 & V9. User Manual

IFS Fiber Module Installation & Operation Instructions

io64 Intelligent Life Safety System

EST3X User Guide P/N EN REV 1.0 ISS 10MAY11

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

4100U City and Relay Cards Installation Instructions

QS1 Technical Reference Manual P/N REV 05 REB 14FEB13

D1255RB/D1256RB/D1257RB

IFS Fiber Module Installation & Operation Instructions

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

FEC403EN Installation Manual

IFS Fiber Module Installation & Operation Instructions

IFS SFP Tranceivers User Manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

UNC100 Integra Manual

KFP-AF Series Fire Alarm Control Panel Installation Manual

KTD-348 Crosspoint 32 Matrix Video Switcher

VS1 Intelligent Life Safety System

IFS Fiber Module Installation & Operation Instructions

Advisor Advanced User Guide

IFS Fiber Module Installation & Operation Instructions

GE Security. ATS1250/ door DGP / 4-lift DGP. Installation guide

ATS Control Panel Manager's manual Version 2.1, 10/2006

System Accessories, LCD Annunciators

OPERATION / INSTALLATION

FiRe mobile-2 Operation Manual

20 Light Remote Annunciator

Installation Instructions. Fire Command Center/Fire Alarm Annunciators D1256/D1257

Transition 500-PIV Series Multi-Technology Readers Installation Manual

QS1 Technical Reference Manual P/N REV 05 REB 14FEB13

LifeAlarm Fire Alarm Control Panels

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

QSC Technical Reference Manual P/N REV 05 REB 14FEB13

EXTINGUISHING AGENT RELEASE MODULE

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Fire Command Keypad. XR5 User s Guide

IFS Fiber Module Installation & Operation

Installation Manual. Wiegand Interface Unit Two-State (WIU-2) North America T F Asia T F

Panel Remote Annunciators Installation Instructions

Independent Zone Control (I.Z.C.)

KTR-11 Face/Badge Reader. Installation Manual

Booster Power Supply Manual

Operator s Manual Part: InfoAlarm Product: 4100U, 4100ES Rev. B

Section 8 System Operation

Section 9 System Operation

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

FMR Installation Instructions. Addressable Fire System Controller

21-light Remote Annunciator. Owner s Manual

LifeAlarm Fire Alarm Controls

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

Series RSM Room Status Monitor. Specifications - Installation and Operating Instructions 5-13/32 [137.16] 8 [203.20] 4-5/8 [117.

NX-181xx NetworX Voice keypad with touch buttons User Manual

user manual Document No , Revision 03 November 2015

180 Degree Ceiling Mounted Occupancy Sensors

Wireless Weather Station. Table of Contents

Print Specification. Publication. Instructions. Specific requirements. General requirements

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

FIRE FIRE. 4100U Fire Alarm. Operator's Manual. Technical Manuals Online! -

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Two-Channel Gas Controller

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Pioneer-R16 Gas Monitor Operator s Manual

Installation, Operating and Maintenance Manual

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

Addressable NAC Output Module D327A

Beacon 110 Gas Monitor Operator s Manual

NetworX NX-548E Receiver Installation Instructions

1. Introduction. 1.1 Features

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

SYSTEM 3400 ANALOGUE ADDRESSABLE FIRE DETECTION. (with Devices) Operating Manual Version 3.3X Issue 2 September 1996

Network Display Unit Installation Instructions

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

SmartTerminal. Installation Commissioning & Operation. Our aim is to provide Consistently Excellent Service in the eyes of our customers MAN1536-6

Product Data Sheet. Remote Terminals. Features:

Oxygen (O2) Single-Point Gas Detection System

4 & 8-POINT ANNUNCIATORS Instruction Manual

Towel Warmer MAKE EVERYDAY A SPA DAY

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Transcription:

GE Security R Series Remote Annunciators and Expander Installation and Operation Guide P/N 3100969 REV 1.0 ISS 15JUL08

Copyright Copyright 2008 GE Security, Inc. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without prior written consent from GE Security, Inc., except where specifically permitted under U.S. and international copyright law. Document number: 3100969 Revision: 00.15 Disclaimer The information in this document is subject to change without notice. GE Security, Inc. ( GE Security ) assumes no responsibility for inaccuracies or omissions and specifically disclaims any liabilities, losses, or risks, personal or otherwise, incurred as a consequence, directly or indirectly, of the use or application of any of the contents of this document. For the latest documentation, contact your local supplier or visit us online at www.gesecurity.com. This publication may contain examples of screen captures and reports used in daily operations. Examples may include fictitious names of individuals and companies. Any similarity to names and addresses of actual businesses or persons is entirely coincidental. Trademarks and patents GE and the GE monogram are registered trademarks of General Electric Company. The R Series Remote Annunciators and Expander name and logo are registered trademarks of GE Security. Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products. Intended use Use this product only for the purpose it was designed for; refer to the data sheet and user documentation for details. For the latest product information, contact your local supplier or visit us online at www.gesecurity.com. FCC compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. You are cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. European Union directives The European directive Waste Electrical and Electronic Equipment (WEEE) aims to minimize the impact of electrical and electronic equipment waste on the environment and human health. For proper treatment, recovery, and recycling, you can return the equipment marked with this symbol to your local supplier upon the purchase of equivalent new equipment, or dispose of it in designated collection points. Further information can be found on the following website: www.recyclethis.info. European representative for manufacture (EMC): GE Security B.V., Kelvinstraat 7, 6003 DH Weert, The Netherlands.

Content Introduction to the R Series 1 Installation features and controls 1 Installing annunciators and expanders 3 Wiring diagrams 6 Troubleshooting 8 Specifications 9 Operating the LCD models 10 Operating the LED models 12 Reading LCD displays 14 System Normal screen 14 Event Message screen 14 Details screen 15 Entering a password 16 Message priorities 17 Index 19 R Series Remote Annunciators and Expander Installation and Operation Guide i

Introduction to the R Series The R Series Remote Annunciators and Expander provide remote annunciation for fire alarm systems. The annunciators offer LCD or LED annunciation, and can include common controls. The expander uses LEDs. The R Series includes three annunciator models and one expander model. One or two expanders can be connected to any of the annunciator models. Figure 1 shows the four models in the R Series. Table 1 lists the features of each model. Table 2 is a complete list of all models and accessories in the series. Figure 1: Models in the R Series Power Fire Alarm Supervisory Ground Fault Trouble Controls Enabled Ack/Silence Power Fire Alarm Supervisory Ground Fault Trouble Controls Enabled Ack/Silence Reset Signal Silence Drill Lamp Test Lamp Test RLCD RLCD-C Power Fire Alarm Supervisory Ground Fault Trouble Controls Enabled Ack/Silence Reset Signal Silence Drill Lamp Test RLED-C RLED24 Table 1: Features of the models Model LCD Display Zone LEDs Common controls System LEDs Buzzer RLCD, RLCD-R, RLCDF Yes No No Yes Yes RLCD-C, RLCD-CR, RLCD-CF Yes No Yes Yes Yes RLED-C, RLED-CR, RLED-CF No 16 pairs Yes Yes Yes RLED24, RLED24R No 24 pairs No No No R Series Remote Annunciators and Expander Installation and Operation Guide 1

Introduction to the R Series The annunciators and expanders can be mounted on a standard 4- inch square electrical box, using the included mounting ring. They can also be surface mounted in locking steel enclosures. The annunciators communicate with the FACP on the RS-485 data riser. This can be configured for Class A or Class B communication. The annunciators do not provide ground fault isolation. The annunciators are stand-alone units that can be powered by the FACP or by an approved power supply. Models with common controls can use a separate, remote key switch to enable or disable the common controls. Table 2: R Series models and accessories Model number Description Model number Description RLCD Remote Annunciator: LCD text annunciator without common controls. English. RA-ENC1 One-position enclosure for Remote Annunciator. RLCD-R RLCDF RLCD-C RLCD-CR RLCD-CF RLED-C RLED-CR RLED-CF RLED24 RLED24R Remote Annunciator: LCD text annunciator without common controls. English. Red. Remote Annunciator: LCD text annunciator without common controls. French. Remote Annunciator:LCD text annunciator with common controls. English. Remote Annunciator:LCD text annunciator with common controls. English. Red. Remote Annunciator:LCD text annunciator with common controls. French. Remote Annunciator: 16-pair LED zone annunciator with common controls. English. Remote Annunciator: 16-pair LED zone annunciator with common controls. English. Red. Remote Annunciator: 16-pair LED zone annunciator with common controls. French. Remote Expander: 24-pair LED zone expander with expander cable and zone card insert. Remote Expander: 24-pair LED zone expander with expander cable and zone card insert. Red. RA-ENC2 RA-ENC3 RKEY RA-LED16ZC RA-LED24ZC Part number Two-position enclosure for Remote Annunciator and one Remote Expander, including one interconnection cable. Three-position enclosure for Remote Annunciator and two Remote Expanders, including two interconnection cables. Remote key switch on plate for enabling or disabling common controls (Lock/Unlock). Zone card insert for RLED-C, RLED-CR, and RLED-CF. Zone card insert for RLED24, RLED24R. Description 27193-16 Electrical box, surface mount, white, singlegang. 7300073 24-inch expander cable assembly, includes cable and hardware. 7120313-01 12-inch expander cable (cable only). 7120313-02 24-inch expander cable (cable only). 2 R Series Remote Annunciators and Expander Installation and Operation Guide

Installation features and controls Figure 2: Annunciator rear view showing terminals and controls Mounting slot DIP switch CH1 (+) IN RS-485 riser terminals CH1 (-) IN CH1 (+) OUT CH1 (-) OUT CH2 (+) IN CH2 (-) IN (-) (+) N/C V (-) V (+) Remote key switch terminals Power terminals CH2 (+) OUT CH2 (-) OUT 24V (+) IN 24V (-) IN F E D C OUT Expander cable terminals 24V (+) OUT B Communication LEDs TX RX 24V (-) OUT A Figure 3: Expander rear view showing terminals Mounting slot V (-) V (-) V (+) V (+) Expander cable terminals IN F E D C B F E D C B OUT Expander cable terminals A A Table 3: DIP switch settings Switch S1 to S5 S6 Description and values Network address. The annunciator network address (in binary). The factory setting is for address 2. See Table 4 for examples. Network baud rate. OFF = 9600 baud (factory default setting) ON = 38,400 baud S7 to S8 Not used R Series Remote Annunciators and Expander Installation and Operation Guide 1

Installation features and controls Table 4: Examples of DIP switch address settings Address Settings Address Settings 1 ON 1 2 3 4 5 6 7 8 5 ON 1 2 3 4 5 6 7 8 2 ON 1 2 3 4 5 6 7 8 6 ON 1 2 3 4 5 6 7 8 3 ON 1 2 3 4 5 6 7 8 7 ON 1 2 3 4 5 6 7 8 4 ON 1 2 3 4 5 6 7 8 8 ON 1 2 3 4 5 6 7 8 2 R Series Remote Annunciators and Expander Installation and Operation Guide

Installing annunciators and expanders Installing annunciators and expanders For correct operation, the annunciator must be configured with a unique network address, must have the correct baud rate setting, and must be in communication with the FACP. If you are installing a Remote Annunciator and Remote Expanders in enclosures RA-ENC2 or RA-ENC3, you must install the expanders first. Refer to the installation sheets for the enclosures for the correct sequence of steps. If you are installing Remote Annunciators and Remote Expanders using separate electrical boxes, the wire runs between the boxes must be enclosed in conduit. If you are installing a remote key switch, the switch must be located within the enclosure, or within 20 feet (6.1 m) of the enclosure with the cabling installed in conduit. To install an annunciator: 1. Secure the mounting ring to the electrical box, as shown in Figure 4. 2. Use the DIP switch to set the correct network address and baud rate. See Table 3 for DIP switch settings. 3. Connect the RS-485 riser to the appropriate annunciator terminals, as per Figure 5 (Class A) or Figure 6 (Class B). Tip: Leave enough wire to remove and position the annunciator when setting the DIP switch. 4. Attach the expander cable to the annunciator, if applicable. See Figure 7. 5. Attach the remote key switch wiring to the annunciator, if applicable. See Figure 8. 6. Tilt the annunciator up and slide the mounting slot onto the onto the top flange of the mounting ring. 7. Tilt the annunciator down and push the bottom of the annunciator over the stud-nut, as shown in Figure 4. 8. Secure the bottom of the annunciator to the mounting ring using the captive screw. 9. Cover the screw hole with the product label plate. R Series Remote Annunciators and Expander Installation and Operation Guide 3

Installing annunciators and expanders To install an expander: 1. Complete and insert the zone card (labeling sheet) into the expander. 2. Secure the mounting ring to the electrical box, as shown in Figure 4. 3. Connect the expander cable to the expander. Attach an expander cable for interconnection to a second expander, if applicable. See Figure 7. 4. Tilt the expander up and slide the mounting slot onto the top flange of the mounting ring. 5. Tilt the expander down and push the bottom of the annunciator over the stud-nut, as shown in Figure 4. 6. Secure the bottom of the annunciator to the mounting ring using the captive screw. 7. Cover the screw hole with the product label plate. 8. Repeat steps 1 through 7 for a second expander, if applicable. 4 R Series Remote Annunciators and Expander Installation and Operation Guide

Installing annunciators and expanders Figure 4: Installing the mounting ring, annunciator, and expander RS-485 RISER ANNUNCIATOR EXPANDER CABLE EXPANDER MOUNTING RING ELECTRICAL BOX R Series Remote Annunciators and Expander Installation and Operation Guide 5

Wiring diagrams Wiring diagrams All wiring is supervised and power-limited, unless otherwise noted. Figure 5: Class A wiring FACP RS-485 CH1 + CH1 CH2 + CH2 LISTED 24 VDC SUPPLY 24 VDC + 24 VDC Annunciator CH1 (+) IN CH1 ( ) IN CH1 (+) OUT CH1 ( ) OUT CH2 (+) IN CH2 ( ) IN CH2 (+) OUT CH2 ( ) OUT 24V (+) IN 24V ( ) IN 24V (+) OUT 24V ( ) OUT GROUND Annunciator CH1 (+) IN CH1 ( ) IN CH1 (+) OUT CH1 ( ) OUT CH2 (+) IN CH2 ( ) IN CH2 (+) OUT CH2 ( ) OUT 24V (+) IN 24V ( ) IN 24V (+) OUT 24V ( ) OUT GROUND Figure 6: Class B wiring FACP RS-485 CH1 + CH1 LISTED 24 VDC SUPPLY 24 VDC + 24 VDC Annunciator CH1 (+) IN CH1 ( ) IN CH1 (+) OUT CH1 ( ) OUT CH2 (+) IN CH2 ( ) IN CH2 (+) OUT CH2 ( ) OUT 24V (+) IN 24V ( ) IN 24V (+) OUT 24V ( ) OUT GROUND Annunciator CH1 (+) IN CH1 ( ) IN CH1 (+) OUT CH1 ( ) OUT CH2 (+) IN CH2 ( ) IN CH2 (+) OUT CH2 ( ) OUT 24V (+) IN 24V ( ) IN 24V (+) OUT 24V ( ) OUT GROUND 6 R Series Remote Annunciators and Expander Installation and Operation Guide

Wiring diagrams Figure 7: Expander wiring Annunciator First Expander Second Expander OUT IN OUT IN OUT V ( ) V ( ) V ( ) V ( ) V ( ) V (+) V (+) V (+) V (+) V (+) F F F F F E E E E E D D D D D C C C C C B B B B B A A A A A Figure 8: Remote key switch wiring Annunciator KEYSWITCH ( ) KEYSWITCH (+) RKey TB1-1 TB1-2 Note: Remote key switch wiring is not supervised. The key switch must be located within 20 feet (6.1 m) of the annunciator and installed in conduit. R Series Remote Annunciators and Expander Installation and Operation Guide 7

Troubleshooting Troubleshooting When an R Series annunciator is operating correctly, the Trouble LED follows the panel s Trouble LED. Annunciators with LCD displays show the same trouble messages as the panel. See the topic Reading LCD displays on page 14 for details about message displays. The following table summarizes symptoms and solutions for common installation and operation problems. Table 5: R Series troubleshooting Problem Panel detail display: Annunciator 000 Communication Fault Cause Communication wiring has an open fault Communication wiring polarity is reversed Annunciator has no power Annunciator address DIP switches are set incorrectly (on the annunciator shown in the panel message) Annunciator network baud rate DIP switch is set incorrectly (for normal operation use 9600 baud) Annunciator LCD and LEDs are inoperative Annunciator control switches don t work Annunciator has no power Remote key switch is in the locked or disabled position Password entry may be required (see Entering a password on page 16) Lamp test During a lamp test the annunciators with LCDs show the version of annunciator firmware currently loaded 8 R Series Remote Annunciators and Expander Installation and Operation Guide

Specifications Specifications Operating voltage Standby current 24 VDC, continuous. Do not use FACP accessory power outputs that are interrupted when the panel is reset. Supply must be UL/ULC Listed for use with fire protective signaling systems and have a rating designation of Regulated 24 DC or Regulated 24 FWR. RLCD, RLCD-R: 98 ma RLCDF: 98 ma RLCD-C, RLCD-CR: 99 ma RLCD-CF: 99 ma RLED-C, RLED-CR: 28 ma RLED-CF: 28 ma RLED24, RLED24R: 6 ma Alarm current RLCD, RLCD-R: 113 ma RLCDF: 113 ma RLCD-C, RLCD-CR: 115 ma RLCD-CF: 115 ma RLED-C, RLED-CR: 62 ma RLED-CF: 62 ma RLED24, RLED24R: 34 ma RS-485 communications Class A or Class B, 9600 baud Data wiring 18 to 14 AWG (1.0 to 2.5 sq mm) twisted pair (6 twists per foot minimum). Maximum wire run is 4,000 ft. (1,219 m) Remote key switch circuit Ground fault impedance Power wiring Display area Dimensions (H x W x D) Mounting Operating environment 5 VDC at 1 ma, power-limited, unsupervised 0 Ω 18 to 14 AWG (1.0 to 2.5 sq. mm) 4 lines of 20 characters each 5-5/8 x 8-1/2 x 1-1/2 in. (14.3 x 21.4 x 3.8 cm) North American 4-inch square electrical box or listed enclosure (see Error! Not a valid result for table.) Temperature: 32 to 120 F (0 to 49 C) Humidity: 0 to 93% RH, noncondensing at 90 F (32 C) R Series Remote Annunciators and Expander Installation and Operation Guide 9

Operating the LCD models Operating the LCD models Figure 9: Controls and indicators for: RLCD, RLCD-R, RLCDF 1 2 3 4 Power Fire Alarm Supervisory Ground Fault Trouble Controls Enabled Ack/Silence Reset Signal Silence Drill Lamp Test 5 6 7 8 9 10 11 12 13 14 15 Figure 10: Controls and indicators for: RLCD-C, RLCD-CR, RLCD-CF 1 Power Fire Alarm Supervisory Ground Fault Trouble Controls Enabled Ack/Silence 5 6 7 8 9 10 11 2 3 4 Lamp Test 15 10 R Series Remote Annunciators and Expander Installation and Operation Guide

Operating the LCD models Table 6: Controls and indicators for the RLCD, RLCD-R, RLCDF, RLCD-C, RLCD-CR, and RLCD-CF No. Item Description 1 LCD display Displays system status, event messages, and event message details 2 Up cursor button Scrolls up through the messages in the event message queue. Scrolls up through characters for password entry. 3 Down cursor button Scrolls down through the messages in the event message queue. Scrolls down through characters for password entry. 4 Enter button Displays message details for the current message. Enters the password character selected. 5 Power LED Green LED that indicates the annunciator is energized 6 Fire Alarm LED Red LED that indicates an active fire alarm state (flashing = new fire alarm event, steady = all current fire alarm events have been acknowledged) 7 Supervisory LED Yellow LED that indicates an active supervisory state (flashing = new supervisory event, steady = all current supervisory events have been acknowledged) 8 Ground Fault LED Yellow LED that indicates a ground fault somewhere in the system 9 Trouble LED Yellow LED that indicates an active trouble state (flashing = new trouble event, steady = all current trouble events have been acknowledged) 10 Controls Enabled LED Yellow LED that indicates the controls in that group are enabled at the annunciator. Enabling the controls requires the level 2 password or the enable controls key. 11 Ack/Silence LED-button Silences the panel buzzer and acknowledges all current events. The LED next to the button indicates the function is active. Requires the level 2 password or the enable controls key to operate. 12 Reset LED-button Restores the system to the normal state, provided that no inputs are latched in the active state. The LED next to the button indicates the reset function is active. Requires the level 2 password or enable controls key to operate. 13 Signal Silence LED-button Turns off (silences) all active audible and common alarm output devices, and if configured, all visible devices. Pressing the button again turns them back on. The LED next to the button indicates the function is active. Requires the level 2 password or the enable controls key to operate. 14 Drill LED-button Turns on all audible and common alarm output devices, and if configured, all visible devices. Pressing the button again turns them back off. The LED next to the button indicates the function is active. Requires the level 2 password to operate. note they ve got to press and hold for 2 seconds before this takes effect 15 Lamp Test LED-button Turns on all LEDs and displays a test pattern on the LCD. The test runs for ten seconds. The LED next to the button indicates the lamp test is running. R Series Remote Annunciators and Expander Installation and Operation Guide 11

Operating the LED models Operating the LED models Figure 11: Controls and indicators for: RLED-C, RLED-CR, RLED-CF 1 2 3 4 Power Fire Alarm Supervisory Ground Fault Trouble Controls Enabled Ack/Silence Reset Signal Silence Drill Lamp Test 5 6 7 8 9 10 11 12 13 14 15 Figure 12: Controls and indicators for the RLED24 and RLED24R 1 2 3 4 12 R Series Remote Annunciators and Expander Installation and Operation Guide

Operating the LED models Table 7: Controls and indicators for the RLED-C, RLED-CR, RLED-CF, RLED24, and RLED24R No. Item Description 1 Active LED Red LED that indicates the zone or device is in the alarm state 2 Trouble LED Yellow LED that indicates the zone or device is in the trouble state 3 Zone description label Zone or device description 4 Supervisory zones The last four zones can be configured as alarm or supervisory. For these zones, the top LED is a red/yellow bicolor LED. Red = fire alarm event. Yellow = supervisory or monitor event. 5 Power LED Green LED that indicates the annunciator is energized 6 Fire Alarm LED Red LED that indicates an active fire alarm state (flashing = new fire alarm event, steady = all current fire alarm events have been acknowledged) 7 Supervisory LED Yellow LED that indicates an active supervisory state (flashing = new supervisory event, steady = all current supervisory events have been acknowledged) 8 Ground Fault LED Yellow LED that indicates a ground fault somewhere in the system 9 Trouble LED Yellow LED that indicates an active trouble state (flashing = new trouble event, steady = all current trouble events have been acknowledged) 10 Controls Enabled LED Yellow LED that indicates the controls in that group are enabled at the annunciator. Enabling the controls requires the level 2 password or the enable controls key. 11 Ack/Silence LED-button Silences the panel buzzer and acknowledges all current events. The LED next to the button indicates the function is active. Requires the level 2 password or the enable controls key to operate. 12 Reset LED-button Restores the system to the normal state, provided that no inputs are latched in the active state. The LED next to the button indicates the reset function is active. Requires the level 2 password or enable controls key to operate. 13 Signal Silence LED-button Turns off (silences) all active audible and common alarm output devices, and if configured, all visible devices. Pressing the button again turns them back on. The LED next to the button indicates the function is active. Requires the level 2 password or the enable controls key to operate. 14 Drill LED-button Turns on all audible and common alarm output devices, and if configured, all visible devices. Pressing the button again turns them back off. The LED next to the button indicates the function is active. Requires the level 2 password to operate. note they ve got to press and hold for 2 seconds before this takes effect 15 Lamp Test LED-button Turns on all LEDs and displays a test pattern on the LCD. The test runs for ten seconds. The LED next to the button indicates the lamp test is running. R Series Remote Annunciators and Expander Installation and Operation Guide 13

Reading LCD displays Reading LCD displays In addition to the system status LEDs, two annunciator models include an LCD display that can show the system status, event messages, or event message details. The display can also be used to enter a password that enables the common control buttons. System Normal screen The LCD display shows the System Normal screen when the control panel is in the normal (quiescent) state. HH:MM:SS MM/DD/YY Your Building System is Normal 1 2 1 Time and date: The system time in 24-hour format and the system date in MM/DD/YY or DD/MM/YY format, depending on the market place. 2 Banner lines: Your facility name (if programmed) and the message System Normal. Event Message screen The LCD display shows the Event Message screen when the control panel enters the fire alarm, supervisory, monitor, trouble, disablement, or test state. Use the up and down cursor buttons to scroll through the messages in the queue. HH:MM:SS AXXX DXXX NNN SSSSSSSSSS RRR MESSAGE LINE 1 XXXXX MESSAGE LINE 2 XXXXX 1 2 3 1 Time and points: The system time in 24-hour format, the number of active points (Annn), and the number of disabled points (Dnnn) currently in the system. 2 Event status: The event number (NNN), the event type (SSSSSSSSSS), and the event status (RRR). The event number is the position of the event in the queue. The event type is alarm, supervisory, trouble, or monitor. The event status is Act for active, or Rst for restored. 3. Event message: The first and second lines of the event message. 14 R Series Remote Annunciators and Expander Installation and Operation Guide

Reading LCD displays Example screen 13:47:00 A003 D000 001 ZONE ALARM ACT East Wing Hallway South Entrance Details screen Pressing the Enter button while an event message is selected displays the Details screen. The system displays this screen as long as you are pressing the Enter button or using the up and down cursor buttons. The system returns to the Event Message screen after approximately 20 seconds of inactivity. You can also toggle between the Event Message and Details screens by pressing and releasing the Enter button. DETAILS P:XX C:XX D:XXX 1 2 DEVICE MESSAGE LINE1 DEVICE MESSAGE LINE2 3 The Details screen provides details about the zone or device that generated the selected event message. If the selected event message is for a zone, the Details display screen shows which devices in the zone are active. 1 Scrolling symbols: The symbols at the right of the screen title line show whether there are more detail messages before or after the current message. Use the up and down cursor buttons to scroll through the detail messages or devices in the zone. The up or down symbols disappear when you reach the start or end of the list (or when there are no off-normal devices). 2 Device address: The panel (P), card (C), and device number (D) that constitute the complete device address for the device generating the event message. 3 Device message lines: If programmed, the device message for the device that generated the event message. This is usually a location description. Example DETAILS P:01 C:01 D:001 East Wing Hallway South Entrance R Series Remote Annunciators and Expander Installation and Operation Guide 15

Entering a password Entering a password When the Controls Enabled LED is off, you need to enter your level 2 password to enable the controls. When you press any of the control buttons, the system displays the Enter Password screen. ENTER PASSWORD?--- SCROLL=+/-NUMBER ENTER =NEXT DIGIT 1 2 3 1 Title line: This is constant text. 2 Password: You use the up and down cursor buttons to scroll through the digits in each position of the password. Each number appears on this line, but is masked as soon as you press the Enter button. 3. Instruction lines: These lines prompt you to press the up and down cursor buttons to select a number, or the Enter button to select a number and move to the next position. To enter a password: 1. Press any of the control buttons. The system displays the Enter Password screen, with the cursor in the first position of the four-digit password field. 2. Press the up or down cursor button to scroll through the numbers until the correct number appears. 3. Press the Enter button to enter that number and move to the next position. When you press Enter, the system masks the number you just entered with an asterisk. 4. Repeat steps 2 and 3 until you ve entered all four digits of the password. If you make a mistake, pressing Enter before filling all four positions will cancel the operation, and return you to the System Normal screen. If you enter an invalid password, the system displays an error message and returns you to the Enter Password screen. 16 R Series Remote Annunciators and Expander Installation and Operation Guide

Message priorities Message priorities Event messages are stored in a single list or queue. Within the queue they are sorted into priority according to the event type and the order of event occurrence. The priority of event types is shown in the following lists. US market place 1. Fire alarm events 2. Supervisory events and Trouble events 3. Other (monitor) events Canadian market place 1. Fire alarm events 2. Supervisory events 3. Trouble events 4. Other (monitor) events European market place 1. Fire alarm events 2. Supervisory events 3. Trouble events 4. Other (monitor) events R Series Remote Annunciators and Expander Installation and Operation Guide 17

Index A accessories available, 2 Ack/Silence LED-button, 11, 13 Act, 14 Active LED, 13 active points, 14 alarm current, 9 annunciators features, 1 installation, 3, 5 models, 1 models and accessories, 2 rear view, 1 arrows, 15 B banner lines, 14 baud rate, 1, 3 C C:XX, 15 card address, 15 Class A, 2, 6 Class B, 2, 6 common controls, 2 communication baud rate, 1 FACP, 2 LEDs, 1 configuration, 1 contrast adjustment, 1 controls common, 2 configuration, 1 passwords, 16 RLCD, 10 RLCD-C, 10 RLCD-CF, 10 RLCD-CR, 10 RLCDF, 10 RLCD-R, 10 RLED24, 12 RLED24R, 12 RLED-C, 12 RLED-CF, 12 RLED-CR, 12 Controls Enabled LED, 11, 13, 16 current, 9 D D:XXX, 15 data wiring, 9 date, 14 description labels, 13 Details screen, 15 device address, 15 description, 13 message, 15 dimensions, 9 DIP switch, 1, 3 disabled points, 14 down cursor button, 11 Drill LED-button, 11, 13 E electrical boxes, 2, 5, 9 enclosures, 2, 3 Enter button, 11 Enter Password screen, 16 entering passwords, 16 event message priorities, 17 Event Message screen, 14 event messages, 15 events, 14 expanders cable terminals, 1 cables, 3, 4 features, 1 installation, 3, 4, 5 models and accessories, 2 rear view, 1 wiring diagrams, 7 F fire alarm events, 17 Fire Alarm LED, 11, 13 G ground fault isolation, 2 Ground Fault LED, 11, 13 H humidity, 9 I indicators RLCD, 10 RLCD-C, 10 RLCD-CF, 10 RLCD-CR, 10 RLCDF, 10 RLCD-R, 10 RLED24, 12 RLED24R, 12 RLED-C, 12 RLED-CF, 12 R Series Remote Annunciators and Expander Installation and Operation Guide 19

Index indicators (continued) RLED-CR, 12 installation, 3 L Lamp Test LED-button, 11, 13 LCD display A999, 14 Act, 14 active points, 14 banner lines, 14 C:XX, 15 D:XXX, 15 D999, 14 Details screen, 15 device address, 15 device messages, 15 disabled points, 14 Enter Password screen, 16 event message, 15 Event Message screen, 14 event status, 14 location, 11 location messages, 15 message lines, 14 P:XX, 15 points, 14 reading, 14 Rst, 14 scrolling symbols, 15 System Normal screen, 14 time, 14 time and date, 14 location message, 15 M message lines, 14 message priorities, 17 models available, 2 monitor events, 17 mounting, 2, 9 mounting rings, 2, 3, 4, 5 mounting slots, 1 N network address, 1, 3 O operating voltage, 9 other events, 17 P P:XX, 15 panel address, 15 passwords, 16 PCD address, 15 Power LED, 11, 13 power supplies, 2 power wiring, 9 priorities, 17 R remote key switch, 2, 1, 3, 7 Reset LED-button, 11, 13 RLCD controls and indicators, 10 RLCD-C controls and indicators, 10 RLCD-CF controls and indicators, 10 RLCD-CR controls and indicators, 10 RLCDF controls and indicators, 10 RLCD-R controls and indicators, 10 RLED24 controls and indicators, 12 RLED24R controls and indicators, 12 RLED-C controls and indicators, 12 RLED-CF controls and indicators, 12 RLED-CR controls and indicators, 12 RS-485 riser, 2 RS-485 riser terminals, 1 Rst, 14 S scrolling symbols, 15 Signal Silence LED-button, 11, 13 specifications, 9 standby current, 9 supervisory events, 17 Supervisory LED, 11, 13 supervisory zones, 13 System Normal screen, 14 T temperature, 9 time, 14 trouble events, 17 Trouble LED, 11, 13 U up cursor button, 11 W wire specifications, 9 wiring diagrams, 6 topic, 6, 7 Z zone card inserts, 2, 4 zone description, 13 20 R Series Remote Annunciators and Expander Installation and Operation Guide