RADIANT HEATING INDIRECT HEATING DIRECT HEATING VELOCI PERFORMANCE PRODUCTS

Similar documents
Flame115 Radiant. Flame115 Specifications. Flame115 Accessories

FORCED AIR SPACE HEATERS

User s Manual and Operating Instructions

User s Manual and Operating Instructions

Service Parts, Kits and Accessories

BM2 patent NEW INFRARED OIL HEATER FIRE 45

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

WINTER SALE Karcher Pump 7 year Warranty HUBINGSPRESSUREWASHERS.COM

User s Manual and Operating Instructions

User s Manual and Operating Instructions

1. GENERAL SAFETY RULES

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

User s Manual & Operating Instructions

CLIMATE CONTROL PRODUCT GUIDE

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

Quest Power Electric Heat EHS 31 Pro

BASEBOARD MICATHERMIC HEATER

PORTABLE HEATERS FOR PROFESSIONAL use

HI Industrial Utility Heater HI Soleus Air International

MS-600 DESICCANT DEHUMIDIFIER

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

User s Manual & Operating Instructions Model Number MH-150NGT-GFA-A

PORTABLE HEATERS FOR PROFESSIONAL USE

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

REFERENCE INFORMATION

INFRARED RADIANT HEATERS

DIRECT FIRED INFRARED PORTABLE HEATER OPERATING INSTRUCTIONS AND OWNER S MANUAL HEATSTAR WARNING :

User s Manual & Operating Instructions

Owner s Manual Phoenix FireBird

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

Click Here To View Item at

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

Tradesman Tradesman K Norseman Workman Sun Blast Premier Foreman Torches. New

Quest Power Electric Heat EHS 62 Pro

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International

Arcotherm Heaters by Cantherm HEATER CATALOGUE

INFRARED RADIANT TUBE HEATER RSTP15C NATURAL GAS RSTP17C

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

OWNERS MANUAL INDIRECT OIL-FIRED HEATERS Models K150-FAI, K275-FAI TABLE OF CONTENTS HEATER SPECIFICATIONS... 2

ELECTRIC HEATERS. Fireball Electric Heaters. 10,200btu HEAT OUTPUT. heating. 30,706btu HEAT OUTPUT. 9,600btu. sales hotline

SELF-CONTAINED POWER MISTER

TECHNICAL SPECIFICATIONS

Corn Flame Energy Corn Stove Model 3000

e Heater/Exhaust Fan/Light User s Guide

5) Do not start or stop the unit by inserting or pulling out the power plug.

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

Ransome Direct Fired Vaporizers VAPORIZERS & HEATERS RH240 RH50, RH80 & RH120. Direct-Fired LP-Gas Vaporizer. RH200 thru RH1000

ASSEMBLY INSTRUCTIONS

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

SUNCOURT RADON FAN MODEL: RDN04 & RDN04-3, RDK04 & RDK04-3 INSTALLATION INSTRUCTIONS

INDUSTRIAL HEATING CATALOG

LUMINOUS A PATIO HEATER LIKE NO OTHER

TRADESMAN FORCED AIR LP/NG HEATERS

ASSEMBLY INSTRUCTIONS

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Mi-T-M carries a full line of portable heaters, built in the same quality tradition you ve come to expect from us.

Operating Instructions

Quest PowerHeat HFC 100 Pro

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

IN020 Rev F Page 1 of 8

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

HEATING HEATING HEATING. Call for rates and reservations

DH-Direct Fired Poultry Farm Diesel Heater

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

ANNUAL HVAC SERVICE AGREEMENT

USER MANUAL. Bottled Water Dispenser SAVE FOR FUTURE USE. Model #

1800(L) Construction Heater

TECHNICAL SPECIFICATIONS

INSTALLATION AND OPERATING MANUAL

Owner's Manual and Instructions

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

DH Series Portable Industrial Unit Blower Air Heaters

Owner s Manual Phoenix Aquadry TX 200

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

Model Numbers MH-16-TTC / MH-32-TTC / MH-47-TTC

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

Installation & Maintenance Instructions

WARNING. PROPANE FORCED AIR HEATER User s Manual & Operating Instructions. Safety Information

GALE FORCE VAF-16R. Ventilation Manual

Repeat procedures for other side.

Single stage operation oil burner

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

1 HP Air Mover. Owner s Manual

55-Gallon Dispenser Package

User s Manual & Operating Instructions Model Numbers MH-40-GFA / MH-60V-GFA-A / MH-125V-GFA-A / MH-150V-GFA-A

Construction Heater. Installation and Maintenance Manual

Installation & Maintenance Manual

Transcription:

VELOCI PERFORMANCE PRODUCTS P 952.746.4825 866.686.4020 F 952.746.4829 866.686.4021 E orders@velociperformance.com www.velociperformance.com RADIANT HEATING INDIRECT HEATING DIRECT HEATING

Flame115 Made Radiant Heaters Are characterized by the absence of moving air, the flame generated by the burner heats the front plate which reaches high temperatures and projects heat outward. Our infrared diesel heaters also have an embedded burner with dedicated fan for a cleaner combustion. This helps to burn and stop all combustion residues, guaranteeing a clean combustion and 99.9% efficiency. Their versatile use allows them to heat objects and spaces more efficiently than traditional heat sources. The Innovation Of The Flame115 Infrared Heater Lies in the elimination of the refractory material cone that surrounds the conical combustion chamber that s typical of other competitor s units. Our heater features a metallic forced air insulation pocket between the combustion chamber and the external protection cone. The cooling air is blown through the pocket by the burner fan. This innovative technology over comes the well-known problem of the fragility and brittleness of the ceramic cone. CSA Approved Directional Cone Locking Mechanism Low Noise Level Built-In Oil Burner With Gear Pump Electronic Flame Control Unit With Metal Casing Screw-on Fuel Gauge AISI 309 L Stainless Steel Cone Shockproof Polythene Fuel Tank Fuel Tank Drain Plug Only 92 lbs. Extendable Sliding Floor Shield Remote Thermostat Plug Patented Triple Cone Design 8 Reinforced Plastic Wheels Flame115 Radiant 48.7019 06VA203 Infrared Portable Heater Flame115 Specifications Measurement Rating Max Power BTU\H 115,160 Fuel Consumption US GAL\H 0.85 Power Supply V, PH, HZ Fan Motor Power Made Radiant Heaters Are characterized by the absence of moving air, the flame generated by the burner heats the front plate which reaches high temperatures and projects heat outward. Our infrared diesel heaters also have an embedded burner with dedicated fan for a cleaner combustion. This helps to burn and stop all combustion residues, guaranteeing a clean combustion and 99.9% efficiency. Their versatile use allows them to heat objects and spaces more efficiently than traditional heat sources. The Innovation Of The Fire155 Infrared Heater Lies in the elimination of the refractory material cone that surrounds the conical combustion chamber that s typical of other competitor s units. Our heater features a metallic forced air insulation pocket between the combustion chamber and the external protection cone. The cooling air is blown through the pocket by the burner fan. This innovative technology over comes the well-known problem of the fragility and brittleness of the ceramic cone. Built-In Oil Burner With Gear Pump Electronic Flame Control Unit With Metal Casing Low Noise Level CSA Approved Patented Triple Cone Design Fuel Lines Wire-Mesh Protected Shockproof Polythene Fuel Tank Thermostat Plug AISI 430 Stainless Steel Combustion Chamber Screw-On Fuel Gauge Fuel Tank Drain Plug Directional Cone Locking Mechanism Single Point Lift Bail 12 Reinforced Plastic Wheels Floor Protection Sliding Shield Fire155 Radiant 48.7001 06VA201 Infrared Portable Heater Fire155 Specifications Measurement Rating Max Power BTU\H 154,237 Fuel Consumption US GAL\H 1.11 120,1,60 Power Supply V, PH, HZ 120, 1, 60 HP (RPM) 1/4 (3,300) Fan Motor Power HP (RPM) 1/4 (3,300) Current Rating AMPS 2.15 Current Rating AMPS 4.1 Tank Capacity US GAL 11.35 Tank Capacity US GAL 17.2 Run Time HOUR 13.4 Run Time HOUR 16 Weight LBS 92 Weight LBS 161 Machine Dim. 36x20x32 Machine Dim. 60x28x42 Shipping Dim. 27x22x28 Shipping Dim. 41x28x42 Cont. 20 /40 /40 HC QTY 84/180/180 Cont. 20 /40 /40 HC QTY 26/56/56 Flame115 Accessories 4 Fire155 48.7101 02AC582 20 F/140 F Thermostat w/ 30 Cable 48.7102 02AC583 Fuel Level Gauge Fire155 Accessories 48.7101 02AC582 20 F/140 F Thermostat w/ 30 Cable & 90 Plug 48.7102 02AC583 Fuel Level Gauge 48.7103 02AC513 Pre-Heated Oil Filter 48.7104 02AC597 Single Fuel Line Kit 5

Blaze Made Blaze Diesel indirect-fired portable heaters with embedded burner with combustion air obtained from the main ventilation fan. The Blaze heaters feature a heat exchanger that contains the flame and expels fumes throughout a chimney connected to the outside. Being indirect-fired, they can be operated indoors and can also be ducted. Four Pass Heat Exchanger Technology The new fourpass heat exchanger technology allows exhaust gases to increase heat exchange with the cooling air and obtain maximum thermal efficiency. Our heaters are the most efficient in the industry. Firestorm Made Firestorm400 Heavy duty diesel indirect-fired portable heaters with embedded burner and dedicated fan for combustion air. The Firestorm heaters feature a heat exchanger that contains the flame and expells fumes throughout a chimney connected to the outside. Being indriect-fired, they can be operated indoors and can also be ducted. Four Pass Heat Exchanger Technology The new fourpass heat exchanger technology allows exhaust gases to increase heat exchange with the cooling air and obtain maximum thermal efficiency. Our heaters are the most efficient in the industry. Approved For Construction Overheating Thermostat Controllable By The Thermostat, Humidistat Or Timer Electronic Flame Control Unit Fuel Tank Drain Plug Hydrocarbon-Resistent Fuel Lines 10 Pneumatic Wheels Blaze Indirect Series 48.7002 02EC202 Blaze100 48.7003 02EC203 Blaze200 w/ Pre-Heat Filter Can Be Controlled By The Thermostat, Humidistat Or Timer Electronic Flame Control Unit Screw On Fuel Tank Cap Anti-shock frame with foldable handle Built-In Oil Burner With Gear Pump Hydrocarbon-Resistent Fuel Lines Fuel Tank Drain Plug 16 Pneumatic Wheels Firestorm400 HC Specifications Measurement Rating Heat Input 2nd Stage BTU/H 411,905 Heat Input 1st Stage BTU/H 272,189 Heat Output 2nd Stage BTU/H 354,239 48.7004 02EC204 Blaze300 w/ Pre-Heat Filter Blaze Accessories Blaze Specifications Blaze100 Blaze200 Blaze300 Firestorm400 HC Indirect Heat Output 1st Stage BTU/H 231,360 Fuel Consumption 2nd Stage US Gal/H 2.97 Measurement Rating Rating Rating 48.7009 02EC260-MT Firestorm400 HC Fuel Consumption 1st Stage US Gal/H 1.96 48.7105 02AC508 Blaze200 & 300 Fuel Level Gauge Heat Input BTU/H 112,141 204,873 293,982 Airflow CFM 3,250 48.7106 02AC556 Fuel Tank Filter 48.7107 02AC511 4 Lifting Brackets 48.7108 02AC597 Single Fuel Line Kit 48.7109 02AC501 Blaze100 12 One Way Duct Adapter Heat Output BTU/H 94,759 183,362 258,704 Fuel Consumption US GAL/H 0.81 1.48 2.17 Heated Airflow CFM 1,020 1,530 2,530 Temperature Rise (@64 F) F 95 136 126 Firestorm400 HC Accessories 48.7114 02AC582 48.7116 02AC632 External Fuel Tank Connection Kit w/ Deaerator (Tiger Loop) Temp. Rise (@64 F) 2nd Stage F 132 Temp. Rise (@64 F) 1st Stage F 108 Power Supply V,PH,Hz 120,1,60 Fan Motor Power HP (RPM) 1 (1,700) 48.7110 02AC502 Blaze200 14 One Way Duct Adapter Power Supply V, PH, HZ 120,1, 60 120, 1, 60 120, 1, 60 48.7118 02AC562 12 x 20 Flexible Air Duct (Three Way) Burner Motor Power HP (RPM) 1/4 (3,300) 48.7111 02AC503 Blaze300 16 One Way Duct Adapter Fan Motor Power HP (RPM) 1/4 (3,300) 5/8 (3,300) 1 (1,700) 48.7120 02AC564 16 x 20 Flexible Air Duct (Two Way) Current Rating AMPS 13 48.7112 02AC546 Blaze200 12 Two Way Duct Adapter Current Rating AMPS 4.05 7.65 11.80 48.7123 02AC511 4 Lifting Brackets Max Length Duct 1-Way/2-Way Ft 100/60 48.7113 02AC505 Blaze300 12 Two Way Duct Adapter Max Length Flex. Duct (1-Way) FT 25 50 75 48.7128 02AC597 Single Fuel Line Kit Max Length Air Inlet Duct Ft 30 48.7114 02AC582 Max Length Flex. Duct (2-Way) FT - - 25 35 48.7177 02AC213 20 x 20 Air Inlet Duct Max Length Fresh Air Intake Ft 15 48.7115 02AC512 External Fuel Tank Connection Kit Flue Size IN 6 6 6 48.7179 02AC504 20 One Way Duct Adapter Flue Size In 6 48.7116 02AC632 External Fuel Tank Connection Kit w/ Deaerator (Tiger Loop) Tank Capacity US GAL 11 17.2 27.7 48.7180 02AC506 16 x 16 Two Way Duct Adapter Tank Capacity US Gal 57 48.7117 02AC513 Blaze100 Pre-Heated Oil Filter Run Time HOUR 14 14 13 48.7184 02AC558 20 Air Inlet Duct Adapter Run Time 2nd Stage - 1st Stage Hr 29-19 48.7118 02AC562 12 x 20 Flexible Air Duct Weight LBS 120 207 275 48.7185 02AC564 16 x 20 Flexible Air Duct Weight LBS 456 48.7119 02AC563 14 x 20 Flexible Air Duct Machine Dim. 50x20x31 57x22x37 69x28x42 48.7186 02AC566 20 x 20 Flexible Air Duct (One Way) Machine Dim. 85x34x54 48.7120 02AC564 16 x 20 Flexible Air Duct Shipping Dim. 46x20x29 52x21x38 67x25x42 48.7198 02AC579 12 x 12 x 12 Three Way Duct Adapter Shipping Dim. 86x30x52 48.7174 02AC507 Blaze100 Fuel Level Gauge Cont. 20 /40 /40 HC QTY 54/132/132 38/82/82 24/52/52 48.7206 02AC510 Fuel Level Gauge Cont. 20 /40 /40 HC Qty 7/16/31 6 7

Inferno Made Inferno Large indirect-fired portable heaters with external burner (gas or diesel). The Inferno heaters are suitable for high volume spaces and can run on diesel or gas (LPG or natural gas), depending on the burner and can be equipped with an axial or a centrifugal fan. Centrifugal fans are very quiet, ensures greater pressure and is particularly recommended for installations with ducts. Blast Made Blast Diesel direct-fired portable heaters with embedded burner with combustion air obtained from the main air fan. The Blast heaters generate hot air and the combustion residues produced by the burner are expelled with the hot air and contribute to its heating. They transform all of the nominal input power (from the fuel) into heat, 100% efficiency. They are the most economical models available in terms for upfront cost and consumption. On the other hand, they can be used only in well ventilated rooms and where indirect-fired heaters are not required by law. Inferno Series Approved For Construction 16 Pneumatic Wheels Electric Control Panel Ventilation Only Mode Controllable By The Thermostat, Humidistat Or Timer Electronic Flame Control Unit Lifting Brackets AISI 430 stainless steel combustion chamber Casing with double steel protection 48.7010 02AG204-MT Inferno700C 48.7011 - - Inferno700C w/ Oil Burner 48.7012 - - Inferno700C w/ Gas Burner TBD - - Inferno90C TBD - - Inferno900C w/ Oil Burner TBD - - Inferno900C w/ Gas Burner Inferno Accessories Inferno Specifications Inferno700C Inferno900C Measurement Rating Rating Heat Input BTU/H 700,000 900,000 Heat Output BTU/H 595,000 765,000 Heated Airflow CFM 7,420 8,830 Fuel Consumption US GAL/H 5.04 6.48 Fuel Consumption NG CFH 685 881 Min. Supply Pressure NG In. Min. 7in W.C. Min. 7in W.C. Blast Direct Series 48.7005 02GE204 Blast250 48.7006 02GE207 Blast360 48.7007 02GE206 Blast600 w/ Pre-Heat Filter Can Be Controlled By The Thermostat, Humidistat Or Timer Electronic Flame Control Unit Screw On Fuel Tank Cap AISI 430 Stainless Steel Combustion Chamber Built-In Oil Burner With Gear Pump Hydrocarbon-Resistent Fuel Lines Fuel Tank Drain Plug 10 Pneumatic Wheels 48.7177 02AC213 20 x 20 Air Inlet Duct Fuel Consumption LP CFH 275 353 48.7022 TBD Blast400 48.7178 02AC327 42 Gallon Fuel Tank (Inferno700C) 48.7181 02AC518 24 One Way Duct Adapter (Inferno700C) Min. Supply Pressure LP In. Min. 8in W.C. Min. 8in W.C. Max Air Temperature F 250 250 Blast Accessories Blast Specifications Blast250 Blast360 Blast400 Blast600 48.7182 02AC521 20 x 20 Two Way Duct Adapter Power Supply V, PH, HZ 220,1,60 220,1,60 48.7121 02AC508 Fuel Level Gauge Measurement Rating Rating Rating Rating 48.7183 02AC535 Air Intake Adapter Fan Motor Power HP (RPM) 3 (1,700) 4 (1,700) 48.7122 02AC556 Fuel Tank Filter Max Power BTU/H 238,947 361,439 361,439 599,524 48.7187 02AC550 200W Pre-Heated Oil Filter Burner Motor Power HP (RPM) 1/4 (3,300) 1/4 (3,300) 48.7123 02AC511 4 Lifting Brackets Fuel Consumption US GAL/H 1.72 2.6 2.6 4.32 48.7190 02AC541 & 02AC550 Oil Burner w/ Pre-Heater Filter (Inferno700C) 48.7191 02AC544 Gas Burner (Inferno700C) Current Rating AMPS 13.5 15 Max Length Duct 1-Way Ft. 300 300 48.7124 02AC512 External Fuel Tank Connection Kit 48.7125 02AC632 External Fuel Tank Connection Kit w/ Deaerator (Tiger Loop) Heated Airflow CFM 1,460 1,795 1,795 2,800 Power Supply V, PH, HZ 120,1, 60 120, 1, 60 120,1,60 120,1,60 48.7194 02AC287 3 Stainless Chimney Max Length Duct 2-Way Ft. 150 150 48.7126 02AC513 200 W Pre-Heated Oil Filter Fan Motor Power HP (RPM) 5/8 (3,300) 5/8 (3,300) 1 (1,700) 1 (1,700) 48.7195 02AC290 Stainless Chimney Elbow Max Length Duct 3-Way Ft. 75 75 48.7127 02AC582 Current Rating AMPS 5.1 6 7.5 11.1 48.7196 02AC284 Stainless Chimney Cap Max Length Duct 4-Way Ft. 40 40 48.7128 02AC597 Single Fuel Line Kit Tank Capacity US GAL 17.2 27.7 27.7 35.6 48.7197 02AC573 Chimney Support Flue Pipe In. 8 8 48.7145 02AC575-1 Blast360 1/4 Pre-Heated Oil Filter Run Time HOUR 10 11 10 8 48.7199 02AC328 55 Gallon Fuel Tank Weight LBS 562 815 48.7146 T20357 Blast 360 2.00 GPH 80 W Nozzle Weight LBS 128 142 190 243 48.7200 02AC428 Fuel Tank Kit 48.7202 02AC542 & 02AC550 48.7203 02AC519 Oil Burner w/ Pre-Heated Filter (Inferno900C) 24 One Way Duct Adapter (Inferno900C) Machine Dim. 100x49x35 109x56x32 Shipping Dim. 79x29x51 90x32x57 Cont. 20 /40 /40 HC QTY 8/16/28 7/15/15 48.7147 E50441 Blast 360 Pressure Switch 48.7148 T20443-1 Blast 360 BFA01-R4 Pump 48.7173 T20304 Blast 250 1.25 GPH 80 S Nozzle Machine Dim. 48x22x34 57x23x36 56x29x43 69x29x44 Shipping Dim. 52x21x38 52x21x38 67x25x42 67x25x42 Cont, 20 /40 /40 HC QTY 38/82/82 28/58/58 24/52/52 24/52/52 8 9

Blast/N Made Blast/N Gas (propane or natural gas) direct-fired portable heaters with embedded burner with a combustion air obtained from the main ventilation fan. The Blast/N heaters generate hot air and the combustion residues produced by the burner are expelled with the hot air and contribute to its heating. They transform all of nominal input power (from the fuel) into heat, 100% efficiency. They are the most economical models available in terms of upfront cost and consumption. These heaters should be used only in well-ventilated areas. Flame115 Replacements 48.7129 E10698 Pump - Motor Coupling 48.7131 I40339 450 mm Micropipe (Pressurized Supply) 48.7135 E40125 Brahma TGRD Control Box 48.7136 E10248 Ignition Electrode 48.7158 E50328 Photo Eye 48.7168 T20118 Danfoss BFA01 Solenoid Spool 48.7169 T20117 Danfoss Solenoid Valve 48.7188 M20204 Axle Clip 48.7208 - - M5 mm x 16 mm Heat Shield Wing Knob 48.7212 C10714 M8x20 Tilt Adjustment Knob 48.7213 I40347 360 mm x 1/4 F Upper Fuel Line Fire155 Replacements 48.7103 02AC513 Pre-Heated Oil Filter 48.7104 02AC597 Single Fuel Line Kit 48.7129 E10698 Pump - Motor Coupling 48.7130 G02076 1,000 mm Ignitor Cable Connect 48.7131 I40339 450 mm Micropipe (Pressurized Supply) 48.7132 T20363 80 W - 0.85 GPH Nozzle 48.7133 T20450 Danfoss BFP21 R3 Pump 48.7134 G11018 Turbo Disc 48.7149 E11233 20 µf Capacitor 48.7151 E40124 Brahma TGRD 91 Control Box 48.7153 E10215 Ignition Electrode Approved For Construction Overheating Thermostat Controllable By The Thermostat, Humidistat Or Timer Electronic Flame Control Unit Fuel Tank Drain Plug AISI 430 stainless steel combustion chamber Hydrocarbon-Resistent Fuel Lines 10 Pneumatic Wheels Blast/N Specifications Blast/N250 Blast/N400 Measurement Rating Rating 48.7214 C30729 Fuel Line Clip 48.7215 I30414 Fuel Filter 48.7216 I40327 Lower Fuel Line 48.7217 I40348 Fuel Return Line 48.7218 C10513-N Wheel Axle Cover 48.7219 T20375 Delavan 80 W - 0.65 GPH Fuel Nozzle 48.7220 G02089 Ignition Electrode Cable 48.7221 E10769 100 W x 120 V x 60 Hz Motor & Capacitor 48.7222 E10769-1 Capacitor 48.7223 T20448 Danfoss BFA01 Fuel Pump Blaze Replacements 48.7135 E40125 Blaze100 Brahma TGRD Control Box 48.7136 E10248 Blaze100 Ignition Electrode 48.7137 T20361 Blaze100 0.55 GPH - 80 W Nozzle 48.7138 T20429-1 Blaze100 Danfoss BFA01 Pump 48.7155 T20206 Filter Cartridge 48.7158 E50328 Photo Eye 48.7160 E10677-110 200 W Motor w/ Capacitor 48.7162 T20201 1/4 Fuel Oil Filter 48.7165 T20234 Oil Filter Kit 48.7168 T20118 Danfoss BFA 01 Solenoid Sppol 48.7169 T20117 Danfoss Solenoid Valve 48.7170 E10930 Brahma Transformer 48.7176 T20212 Oil Filter Housing 48.7188 M20204 Axle Clip 48.7208 - - M5 mm x 16 mm Heat Shield Wing Knob 48.7210 G06322 M8 x 25 Tilt Adjustment Knob 48.7218 C10513-N Wheel Axle Cover Blaze Replacements Cont. Blast/N Direct Series Max Power NG/LP BTU/H 254,683 402,767 Feul Consumption NG CFH 242 381 48.7139 T20355 Blaze100 1.10 GPH - 80 W Nozzle 48.7140 T20410-1 Blaze200 Danfoss BFP Pump 48.7157 G02078 Blaze100, 200 & 300 90 Cable Connect 48.7158 E50328 Blaze100, 200 & 300 Photo Eye 48.7023 03GA201 Blast/N250 Fuel Consumption LP CFH 89 145 48.7141 E11249 Blaze300 Capacitor 80 µf 48.7159 I40192 Blaze100, 200 & 300 Micropipe 48.7008 03GA202 Blast/N400 Heated Airflow CFM 2,766 4,120 48.7142 E10514 Blaze300 K2 Coupling 48.7160 E10677-110 Blaze100 200 W Motor w/ Condenser Temperature Rise (@64 F) F 86 103 48.7143 E10704-110 Blaze300 750 W Motor w/ Capacitor 48.7161 E10678-110 Blaze200 450W Motor w/ Capacitor Blast/N Accessories Max Length Flex. Duct Ft 50 50 48.7144 T20411-1 Blaze300 Danfoss BFPC21 Pump 48.7163 T20239 Blaze200 & 300 Pre-Heated Filter 1/4" Max Air Static Press. Avail. PA 150 140 48.7149 E11233 Blaze100 Capacitor 20 µf 48.7164 T20241 Blaze200 & 300 O-Ring Kit for Filter 48.7120 02AC564 Blast/N250 16 x 20 Flexible Air Duct 48.7127 02AC582 48.7186 02AC566 Blast/N400 20 x 20 Flexible Air Duct Power Supply V, PH, HZ 120,1,60 120,1,60 Fan Motor Power HP (RPM) 5/8 (3,300) 1 (1,700) Current Rating AMPS 5 8.5 48.7150 E11230 Blaze200 Capacitor 40 µf 48.7151 E40124 Blaze200 & 300 120 V Brahma TGRD Control Box 48.7152 E10513 Blaze100 & 200 K1 Coupling 48.7165 T20234 Blaze100 O-Ring Kit for Filter 48.7166 E50440 Blaze100 200 & 300 Pressure Switch 48.7167 E11125 Blaze200 Relay Finder 65.31 AC 48.7189 02AC589 Blast/N400 20 Duct Adapter Weight LBS 139 233 48.7153 E10215 Blaze200 & 300 Electrode 48.7171 G01077 Blaze100 200 & 300 Turbo Disc TBD 02AC592 Blast/N250 16 Duct Adapter Machine Dim. 46x32x22 61x35x39 48.7154 T20242 Blaze100, 200 & 300 Filter Cartridge 48.7172 T20356 Blaze300 1.50 GPH - 80 W Nozzle Shipping Dim. 43x22x30 58x25x33 48.7155 T20206 Blaze100 Filter Cartridge 48.7192 02AC285 Blaze SS Chimney Duct 150mm x 1 meter Cont. 20 /40 /40 HC QTY 60/129/129 26/54/81 48.7156 E10313 Blaze200 & 300 6 x 30 20 A Fuse 48.7193 02AC282 Blaze SS Chimney Cap 150mm 10 11

Portable Heaters Warranty PAYMENT: Standard terms are 50% of the sales order is due upon receipt of the goods. Net 30 days on the remaining balance. A second invoice will be sent out detailing this. A service charge of 1.5 % per month may be assessed on invoices over 30 days. SHIPPING: Freight will be pre-paid by Veloci Performance Products for all purchase orders of two machines or more. In the case of shipping one machine, Veloci Performance Products will pre-pay and add to the total of the invoice. PRICING: Veloci Performance Products reserves the right to change discounts and/or prices without notice. Trade discounts are based upon unit and dollar volume and are inclusive of warranty allowance. A surcharge may be added to individual orders in response to foreign currency exchange rate fluctuations. - Price list effective April 1st, 2016 - Subject to change without notice - All prices F.O.B. Savage, Minnesota - The price in effect at time of shipment will apply. - Pricing discrepancies must be filed within 30 days of invoice RETURNS: - Return for credit must be requested within 30 days of shipment & pre-approved by Veloci Performance Products - All returns must be sent freight paid. - A return authorization number and invoice copy must accompany all returns. - Please note that a 20% restocking charge will be assessed. SHIPPING DISCREPANCIES: Discrepancies must be submitted within 48 hours of receipt of goods. Possession of this catalog or any other Veloci Performance Products. material should not be construed as an offer to sell. STATEMENT OF WARRANTY LIMITED WARRANTY ON MTM HEAT PRODUCTS Veloci Performance Products warrants that its products will be free from defects in material and workmanship under normal use for the period of one (1) year. Proof of Purchase must be provided at the time warranty service is requested. Therefore, you should keep your sales slip or invoice from the original purchase. Exclusions: This warranty does not cover freight damage, freezing damage, normal wear and tear from ordinary use, or damage caused by misapplication, fault, negligence, alterations, improper installation or improper maintenance and service by you or any third party that affects the performance or reliability of the product. Failure to perform normal and routine maintenance on the heater, damage related to insects, birds, or animals of any kind and damage due to weather conditions will not be not covered. This warranty does not include wear items, such as, filters, vanes, nozzles and rotors. In addition, the Limited Warranty does not cover damage to the finish, such as, scratches, dents, discoloration, rust or other weather damage after purchase. Normal use does not include use in excess of recommended maximum speeds, flows, pressures, vacuums and temperatures, or use requiring handling of fluids not compatible with components and materials noted in Veloci Performance Products products catalog, technical literature, and instructions. All Transportation costs for the return of the damaged equipment or components will be the responsibility of the purchaser. If defective Veloci Performance Products will repair or replace the defective part or equipment and return the item freight prepaid. If the item is not defective or operating normally, the item will be returned freight collect. This limited warranty is the exclusive warranty Veloci Performance Products makes no other warranty, express or implied, included but not limited to any warranty of merchantability or fitness for a particular purpose. Veloci Performance Products obligations under this warranty is, at Veloci Performance Products option during the limited warranty period, to either repair the defective part or equipment or replace with a new part or equipment upon return of the entire product to the Veloci Performance Products. This is the exclusive remedy for any breach of warranty. In no event shall Veloci Performance Products be liable for any special, indirect, incidental, punitive or consequential damages of any kind, whether for breach of any warranty, for negligence on the basis of strict liability, or otherwise. Some states do not allow the exclusion or limitation on how long a warranty lasts, so the above exclusion and limitations may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state For Service or Warranty, contact Customer Service Veloci Performance Products, 12800 South Highway 13 Suite 500, Savage, MN 55378 866.686.4020 / 952.746.4825 / Fax 866.686.4021 Monday - Friday 8:00 a.m. - 5:00 p.m. CST 09 12 13