The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range

Similar documents
Introduction. Our boilers are among the most efficient available, designed to be easy to install, reliable and economical.

Duo-tec combi, Megaflo system and Solo heat only boilers. Range guide

Bermuda BBU HE!?VG!CPKSB? FGEF CD AGCLAW >90%!?AI!MGJCP 4LGR UGRF 5?JMP #GKCLQGML %GPCDPMLR

Baxi 600, 400 & 200 boilers. Range guide

Baxi Bermuda high efficiency Back Boiler Unit with Valor Dimension Firefront

INDEPENDENT COMBINATION & SYSTEM BOILERS.

The Main Heating Range Guide. The Main Heating range of affordable combi, system and heat only boilers, cylinders and water heaters.

Contacts: Potterton. For latest prices and delivery to your door visit MyTub Ltd

Baxi Combi HE Range. Baxi Combi HE. Keeping Britain Warm

A homeowner s guide to the Baxi Neta-tec Combi

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Compact HRE Boiler Range. The smart choice for heating and hot water

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

thermocompact High performance system boiler range

DOMESTIC BOILER RANGE & ACCESSORIES.

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

turbomax plus High performance combination boiler range

Compact HRE and ECO RF Boiler Range. The smart choice for heating and hot water

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

Sirius FS. Working towards a cleaner future

The iqe Boiler Range. Combination and System T Boilers.

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER

ecotec plus New high efficiency condensing combination and system boiler ranges

Stored Water District Heating Interface Units. Heat Interface Units

DOMESTIC BOILER RANGE & ACCESSORIES FROM IDEAL BOILERS.

Installation and Service Manual. Gold Heat Condensing Central Heating Boiler

ecomax pro High efficiency condensing boiler range for traditional systems

Compact HE. High efficiency combi boiler. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

aquaplus High performance combination boiler with integrated power store

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

Installation & Servicing Instructions

DOMESTIC BOILER RANGE & ACCESSORIES FROM IDEAL BOILERS.

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

Baxi Bermuda BBU 15 HE. Installation & Servicing Instructions. Condensing Back Boiler Unit

NEW BUILD YOUR COMPLETE SOLUTION.

Product Guide Gas-fired and solar thermal. heating and hot water solutions NEW. Greenstar Comfort controls

Installation and Service Manual. Promax SL Condensing Central Heating Boiler

Sirius WH. Working towards a cleaner future

SEDBUK & HARP. the complete range of oil and gas fired condensing boilers. Warmflow Boilers HIGH EFFICIENCY

EcoBlue Combi Installation and Service Manual. Gas Fired Wall Mounted Condensing Combination Boiler. Model Range (09/14)

Baxi Megaflo System HE IE Range. Installation & Servicing Instructions. Gas Fired Wall Mounted Condensing Boiler

Installation and Service Manual. Mega o System Gas Fired Wall Mounted Condensing System Boiler

Installation and Service Manual. Promax System Condensing System Boiler

Compact 24 SE. Standard efficiency combi boiler. Users Instructions. Installation & Servicing Instructions. GC No

Installation and Service Manual. Duo-tec Combi LPG. Gas Fired Wall Mounted Condensing Combination Boiler

Neta-tec Plus Combi GA Range. Installation & Servicing Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

This is a Wall Mounted Powered Flue Condensing Combination Boiler Gas Fired Central Heating Unit.

Performa System 12e, 18e, 24e & 28e

Platinum Combi HE A Range. Installation & Servicing Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy

Installation and Service Manual. Titanium Combi Condensing Combination Boiler

Installation and Service Manual. Platinum Combi Gas Fired Wall Mounted Condensing Combination Boiler

Installation & Service Instructions. Promax SL Range. Condensing Central Heating Boiler. You can rely on

WALL-HUNG SYSTEM & UNVENTED CYLINDERS

Installation & Service Instructions. Promax SL Range. Supplied by HeatingSpares247.com. Condensing Central Heating Boiler.

ecotec plus 937 Power store high efficiency combination boiler

MICROGENUS HE WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILER. minimum space HIGH EFFICIENCY

Installation & Service Instructions. Gold FSB 30 HE. Floor Standing Condensing Boiler. You can rely on

1 VICTRIX ZEUS Superior kw I features

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Compact. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Installation and Service Manual. Promax Combi Condensing Combination Boiler

This is a Wall Mounted Powered Flue Condensing Combination Boiler Gas Fired Central Heating Unit.

Megaflo System HE A Range. Installation & Servicing Instructions. Gas Fired Wall Mounted Condensing Boiler

Installation & Service Instructions. Heatmax Combi HE Range. Condensing Combination Boiler

Megaflo 2 System Compact GA Range. Installation & Servicing Instructions. Gas Fired Wall Mounted Condensing System Boiler

Platinum Combi HE A Range. Installation & Servicing Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Alpha CD13R,18R and 24R

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

Duo-tec 2 Combi GA Range. Installation & Servicing Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

HomeCare

CBX 24, 32 & 38 SBX 30

Our Boiler Family Our Boiler Family

Installation and Service Manual Combi. Condensing Combination Boiler

kw Btu/h Metres Feet l/min. Gal/min C C

Gold Combi 24, 28 & 33 HE. Installation & Service Instructions

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

Light commercial products. High output boilers Cascade systems

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

Combined electric boiler and domestic hot water store

PRODUCT CATALOGUE Issue 3 SYSTEM BOILERS COMBI BOILERS FLOOR STANDING BOILERS WATER HEATERS SPARE PARTS AFTER SALES SERVICE TRAINING

30 SD & 45 SD CONDENSING BOILERS

Combi Eco Range. Installation & Service Instructions

Linea ONE. High efficiency combi boiler. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

CNTENTS. 1Introduction

System Eco Elite Range. Installation & Service Instructions

Bosch Group. 15SBi / 24SBi. WALL MOUNTED BOILERS FOR CENTRAL HEATING and Indirect supply of domestic hot water

Baxi Combi 80 Maxflue

Domestic heating solutions

Installation & Service Manual. Main Eco Elite System Condensing Central Heating Boiler

New Zealand Sales Hotline: Sales Fax:

Installation & Service Instructions Suprima HE Condensing Central Heating Boiler

Residential Heating Boilers

Promax System HE Plus Range. Installation & Service Instructions

Unvented water heating

Performa 24 Eco HE. Installation & Service Instructions. Condensing Combination Boiler

Transcription:

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range Install warmth, efficiency & peace of mind

Contents Solo HE A 1 Megaflo System HE A IE 4 Bermuda BBU HE 7 Flue Options 10 The GA range of combi and system boilers from Baxi 14 Baxi Neta - tec Combi GA and Baxi Neta - tec Plus Combi GA 17 Baxi Megaflo System Compact GA 20 Accessories and controls 23 Flue options 25

Solo HE A Baxi Solo HE A boilers have always been popular with both installers and homeowners alike. The simple contemporary lines and soft curves are bound to appeal to customers, as will the beautifully simple controls that make it easy to use. Its clean, compact design makes it perfect where space is limited. It may be small in size, but it s big in performance, with an extended range of models now available, making it the perfect heating only choice for any size property. >90% SEDBUK 2005 Band A (>90%) Key features & benefits: 5-year parts and labour warranty* giving customers complete peace of mind through heateam SEDBUK 2005 Band A (>90%) rated An Energy Saving Trust recommended product Available in five outputs 12kW, 15kW, 18kW, 24kW and 30kW, this modulating boiler fits most size systems Lightweight, compact design for flexible siting Can be installed on a fully TRV system Suitable for use with open vented or sealed heating systems Simple controls for easy operation No pump overrun required, meaning this boiler will directly replace any existing heat only boiler *Subject to registration and an annual service 1

Solo HE A Return pipe connection (behind) Flow switch Heat exchanger Flow pipe connection Wiring terminal Burner Airbox Gas valve (behind) Fan protection thermostat Fan assembly Condensate trap PCB housing Megaflo Eco SystemFit The Baxi Solo HE A is compatible with the Heatrae Sadia Megaflo Eco SystemFit cylinder Available in 125-300 litre capacities Supplied with primary expansion vessel and programmable thermostat with timed Domestic Hot Water (DHW) Control Up to 70% quicker to install Lifetime cylinder guarantee For further details on the Megaflo range, please call 01603 420220 or visit www.heatraesadia.com Fully modulating outputs SEDBUK 2005 Band A (>90%) Ultra low NOx emissions class 5 - helping to protect the environment Can be located in unventilated cupboards or compartments 2

Technical specifications 5mm Min 390mm 5mm Min Baxi Solo HE Series: Wall mounted high efficiency boilers 12 HE A 15 HE A 18 HE A 24 HE A 30 HE A Sales codes 5120295 5117783 5120296 5117784 5117785 200mm Min CONTROLS Concealed User Controls Yes Yes Yes Yes Yes User Adjustable CH Temperature Yes Yes Yes Yes Yes LED Status/Fault Diagnosis Display Yes Yes Yes Yes Yes GAS Gas Supply Pipe Size mm 15 15 15 15 15 600mm Natural Gas Yes Yes Yes Yes Yes LPG (Butane/Propane) No No No No No Nominal Inlet Supply Pressure mbar 20 20 20 20 20 Maximum Gas Rate m 3 /hr 1.34 1.64 1.94 2.31 2.95 Heat Input Central Heating kw Max Gross 13.3 16.9 20.2 24.5 33.8 kw Max Net 12.0 15.2 18.2 22.1 30.4 Heat Output CH Non Condensing kw Max 11.8 15.2 17.8 22 30.2 50mm Min Heat Output CH Condensing kw Max 12.8 16.5 19.3 23.8 32.6 Seasonal Efficiency % 90.5 91.3 90.4 90.9 90.9 SEDBUK Rating Band A A A A A NOx Class 5 5 5 5 5 NO x Levels mg/kwh 13.1 29.0 11.7 37.0 48.0 ELECTRICAL Electrical Supply Volts/Hz 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz Permanent Live Required No No No No No Electrical Cable Required 3 core x 0.75mm 2 Atleast1.5 Power Consumption Watts 80 80 80 80 80 External Fuse Rating Amps 3 3 3 3 3 Internal Fuse Rating Amps 3.15 3.15 3.15 3.15 3.15 Ingress Protection Rating IPX2 IPX2 IPX2 IPX2 IPX2 (without electro-mechanical timer fitted) Integral 'Boiler Only' Frost Thermostat No No No No No Pump Overrun No No No No No 500mm Min MECHANICAL & HYDRAULIC For Servicing Purposes Compartment Ventilation Required None None None None None Flow & Return Pipe Size mm 22 22 22 22 22 Condensate Discharge Pipe Connection mm 21.5 21.5 21.5 21.5 21.5 Bypass Required No No No No No Vertical Pipe Route Within Case CH System Inhibitor Required Yes Yes Yes Yes Yes CONCENTRIC FLUE SYSTEM 298mm Outside Diameter mm 110 110 110 110 110 5mm Min Standard Horizontal Flue Kit Length mm 850 850 850 850 850 In Operation Max Equivalent Length Horizontal m 4 plus Terminal Max Equivalent Length Vertical m 4 plus Terminal Equivalent Length per 135 Bend m 0.5 0.5 0.5 0.5 0.5 Equivalent Length per 93 Bend m 1 1 1 1 1 TWIN PIPE FLUE SYSTEM Diameters mm 80/80 80/80 80/80 80/80 80/80 Max Equivalent Length Horizontal (parallel pipes) m 75 75 75 75 75 Max Equivalent Length Vertical (parallel pipes) m 75 75 75 75 75 Equivalent Length per 135 Bend m 1.3 Air & 2.6 Flue Equivalent Length per 90 Bend m 4.8 Air & 9.6 Flue WEIGHTS Max Installer Lift Weight kg 26 26 26 26 26 Gross Packaged Boiler Weight kg 36.2 36.2 36.2 36.2 36.2 3

Megaflo System HE A IE The Baxi Megaflo System HE A is designed for fully pumped sealed systems - and because it s fully modulating, it s the perfect choice for a wide range of applications. The Baxi Megaflo System HE A is a sealed system boiler and can be installed with an unvented cylinder for mains pressure hot water at each hot tap in the house. It s ideal for fitting in unventilated cupboards, and comes with a wall mounting frame and integral isolating valves for easy pre-plumbing and flushing of the system prior to fitting. >90% SEDBUK 2005 Band A (>90%) Key features & benefits: 5-year parts and labour warranty* giving customers complete peace of mind through heateam SEDBUK 2005 Band A (>90%) rated An Energy Saving Trust recommended product Available in five outputs; 15kW, 18kW, 24kW, 28kW and 32kW, this modulating boiler fits most size systems. Supplied with pre-plumbing jig for easier and labour saving installation Integral automatic bypass, suitable for systems incorporating TRVs to every radiator Comprehensive range of flue options for quick installation Built in frost thermostat for flexible siting *Subject to registration and an annual service. Terms & Conditions apply. For full details visit www.baxi.co.uk/warranty 4

Megaflo System HE A IE Igniter Stainless steel heat exchanger Combustion box cover and burner Expansion vessel Spark electrode Air/gas collector Venturi Flame sensing electrode Fan assembly Gas valve Pump Condensate trap (behind) Pressure relief valve PCB housing Pressure gauge Megaflo Eco Unvented Cylinder The Baxi Megaflo System HE A is compatible with the Heatrae Sadia Megaflo Eco unvented cylinder Available in 70-300 litre options in both direct and indirect models Patented cold water inlet diffuser minimises mixing of cold and hot water High performance 'coil in coil' heat exchanger Lifetime transferable cylinder guarantee For further details on the Megaflo range, please call 01603 420220 or visit www.heatraesadia.com Fully modulating outputs SEDBUK 2005 Band A (>90%) Ultra low NOx emissions class 5 - helping to protect the environment Can be located in unventilated cupboards or compartments 5

Technical specifications 5mm Min 450mm Min For Servicing Purposes 5mm Min In Operation 450mm 345mm 5mm Min 200mm Min (300mm Min if using 80/125mm flueing system) 780mm 150mm Min* * This is the MINIMUM recommended dimension. Greater clearance will aid installation and maintenance At least 1.5 Baxi Megaflo System HE A: Wall mounted high efficiency boilers 15 HE A 18 HEA 24 HEA 28 HEA 32 HEA Sales code 5121343 5121344 5118063 5118648 5121345 CONTROLS Concealed User Controls Yes Yes Yes Yes Yes On/Off Switch with Reset Yes Yes Yes Yes Yes User Adjustable CH Temperature Yes Yes Yes Yes Yes LED Temp/Status/Fault Diagnosis Display GAS 2 digits & 3 LEDs Gas Supply Pipe Size mm 22 22 22 22 22 Natural Gas Yes Yes Yes Yes Yes Nominal Inlet Supply Pressure mbar 20 20 20 20 20 Max Gas Rate NG m 3 /hr/kg/hr 1.69 1.95 2.61 3.10 3.48 Heat Input Central Heating kw Max Gross 17.1 20.5 27.4 32.1 36.4 kw Max Net 15.4 18.5 24.7 28.9 32.8 kw Min Gross 4.4 4.8 7.8 10.8 10.8 kw Min Net 4.0 4.3 7 9.7 9.7 Heat Output CH Non Condensing (70 Mean) kw Max 15 18 24 28 32 kw Min 3.9 4.2 6.8 9.4 9.4 Heat Output CH Condensing (40 Mean) kw Max 16.2 19.4 25.9 30.3 34.4 kw Min 4.2 4.5 7.4 10.2 10.2 Seasonal Efficiency NG % 91.2 91.2 91.2 91.2 91.2 SEDBUK Rating Band A A A A A NOx Class 5 5 5 5 5 NO x Levels mg/kwhr 27.5 31.7 22.3 21.8 26.8 ELECTRICAL Electrical Supply Volts/Hz 230V/50Hz Permanent Live Required Yes Yes Yes Yes Yes Fitted Electrical Cable 1m x 3 core x 0.75mm 2 Power Consumption Watts 130 140 150 160 160 External Fuse Rating Amps 3 3 3 3 3 Internal Fuse Rating Amps F2L F2L F2L F2L F2L Ingress Protection Rating IPX5D IPX5D IPX5D IPX5D IPX5D (without electro-mechanical timer fitted) 24 hour Pump Exercise Yes Yes Yes Yes Yes Pump Overrun Yes Yes Yes Yes Yes Integral 'Boiler Only' Frost Thermostat Yes Yes Yes Yes Yes MECHANICAL & HYDRAULIC Compartment Ventilation Requirement None None None None None Pre-plumbing/Wall Mounting Jig Yes Yes Yes Yes Yes Flow / Return Pipe Size mm 22 22 22 22 22 Condensate Discharge Pipe Size mm 21.5 21.5 21.5 21.5 21.5 Integral Automatic Bypass Yes Yes Yes Yes Yes Safety Discharge Pressure bar 3 3 3 3 3 Integral Expansion Vessel litres 8 8 8 10 10 Maximum Capacity of CH System litres 125 125 125 125 125 CH System Inhibitor Required Yes Yes Yes Yes Yes CONCENTRIC FLUE SYSTEM Standard Telescopic Horizontal Flue Kit Length mm 315-500 315-500 315-500 315-500 315-500 Max Equivalent Length Horizontal/Vertical (60/100mm) m 10 10 10 10 10 Max Equivalent Length Vertical Horizontal/Vertical (80/125m) m 20 20 20 20 20 Equivalent Length per 135 Bend m 0.5 0.5 0.5 0.5 0.5 Equivalent Length per 93 Bend m 1 1 1 1 1 TWIN PIPE FLUE SYSTEM Diameters mm 80/80 80/80 80/80 80/80 80/80 Max Equivalent Length Horizontal/Vertical (parallel pipes) m 15/15 15/15 15/15 15/15 15/15 Equivalent Length per 135 Bend m 0.25 0.25 0.25 0.25 0.25 Equivalent Length per 91.5 Bend m 0.5 0.5 0.5 0.5 0.5 WEIGHTS Max Installation Lift Weight kg 38.6 38.6 39.2 41 41 Gross Packaged Boiler Weight kg 43.6 43.6 44.2 46 46 6

Bermuda BBU HE The original Baxi Bermuda Back Boiler Unit (BBU), launched in 1966, was so practical and reliable that Baxi installations accounted for 80% of the back boilers installed in the UK & Ireland. Times changed and so did boilers, but with the introduction of our innovative Baxi Bermuda BBU HE we continue our tradition of back boiler expertise. As the only high efficiency BBU in the UK, it s the easiest way to replace an existing BBU. >90% SEDBUK 2005 Band A (>90%) Key features & benefits: 2-year parts and labour warranty* giving customers complete peace of mind through heateam SEDBUK 2005 Band A (>90%) rated An Energy Saving Trust recommended product 15kW heat output; modulating boiler adapts to heat demand ensuring optimum performance at all times Built in condensate pump and no pump overrun required, to ease installation Factory set to enable easy boiler commissioning Single piece flexible concentric flue; eliminates the need to provide flue inspection access Room sealed appliance; eliminating the need for air vents in the room Simple to use external boiler controls located on the dedicated TM firefront Quiet in operation *Subject to registration and an annual service 7

630mm min height inside builders opening 595mm (Reg alia refront ONLY - 575mm ) Technical specifications Baxi Bermuda BBU HE Baxi SalesBermuda code BBU HE 710153301 CONTROLS Concealed User Controls Yes User Adjustable CH Temperature Factory Preset LED Status/Fault Diagnosis Display Yes GAS Gas Supply Pipe Size mm 15mm compression Natural Gas Yes LPG (Butane/Propane) No Nominal Inlet Supply Pressure m 3 /hr 20 Maximum Gas Rate 1.63 Heat Input Central Heating kw Max Gross 17.1 kw Max Net 15.38 Heat Output CH Non Condensing kw Max 15 Heat Output CH Condensing kw Max 15.7 % 90.1 SEDBUK Rating Band A NOx Class 5 NOx Levels mg/kwh 31 ELECTRICAL Electrical Supply Volts/Hz 230/50Hz Permanent Live Required Yes Electrical Cable Required 4 core wire Power Consumption Watts 112 External Fuse Rating Amps 3 Internal Fuse Rating Amps 3.15 Ingress Protection Rating IPXO Pump Overrun Not not required MECHANICAL & HYDRAULIC Compartment Ventilation Required No Flow & Return Pipe Size mm 22 male copper Condensate Discharge Pipe Connection mm 10 Bypass Required Yes (pressure operated) Vertical Pipe Route No no inverted pipework permitted CH System Inhibitor Required Yes CONCENTRIC FLUE SYSTEM Outside Diameter mm 100 Max Equivalent Length Vertical m 10 or 1012.5 WEIGHTS Max Installer Lift Weight kg 27 Gross Packaged Boiler Weight kg 28 ACCESSORIES Right Hand Plumb Kit 720111701 Site requirements Boiler dimensions Connections & Fittings Flue Sampling Point W W (Width) = 430mm including connections & fittings Air Vent D (Depth) = 330mm including flue sampling point Site requirements 630mm min SURROUNDOR FINISHED WALL FACE HEARTH LEVEL Builders Opening Fireplace Opening 490mm 560mm min Connections & Fittings Solid, non combustible hearth tosupport the boiler, as speci ed in BS 5871. 450mm min 400mm min (with spacer) 486mm min (Regalia ONLY) D H H (Height) = 550mm including air vent 1 To accommodate the firefront without the need for additional spacers, there must be a gap of at least 95mm from the surround or finished face to the front of the boiler. 2 If necessary this gap can be increased by the use of spacer kits. Each spacer increases the effective depth of the opening by up to 50mm. Alternatively a 2 If range necessary of rebated this gap fire can surrounds be increased are available. by the use of spacer kits. Each spacer increases the effective depth of the opening by up to 50mm. Alternatively a 3 range When of surveys rebated highlight fire surrounds that space are is available. restricted versus minimum site requirements, the use of rebated surrounds is recommended. 8

Fire and accessories technical specifications FIRES All measurements givenininmmm Model Fire only Boiler & Fire Fascia Height Fascia Width Fascia Depth Engine Depth Spacer Depth Dimension TM Regalia BBU FireFront + 05847A1 720331401 720 600 45 144 50 * Dimension TM Innova BBU FireFront 0584711 720331301 632 542 38 144 50 Dimension TM Classica Brass BBU FireFront + 0584721 720330701 615 512 51 144 50 Dimension TM Classica Pewter BBU FireFront + 0584701 720330801 615 512 51 144 50 Dimension TM Dream Gold BBU FireFront + 05847C1 720331001 636 518 79 144 50 Dimension TM Dream Chrome BBU FireFront + 05847D1 720331101 636 518 79 144 50 Dimension TM Lyrica BBU FireFront + 0584511 720331601 612 510 74 144 50 FIRES ACCESSORIES All measurements givenininmmm Model Part Number Height Width Depth Rebate Classica, Lyrica, Nano & Innova Spacer Kit 5135632 610 503 50 NA Regalia Spacer Kit 5135633 715 586 50 NA Dream Spacer Kit 5135634 625 504 50 NA Right Hand Plumb Kit 720111701 NA NA NA NA BBU Wall Fascia 05847H1 750 650 157 NA > 10m Concentric Flexible Flue 710143901 Dimension 100mm (complete with terminal) Flue Pull Cone # 720111801 Dimension 100mm (complete with terminal) + This fire is floor standing only. This fire can be wall mounted or floor standing. For use with the Innova fire # The flue pull cone must be used for pulling the concentric flexible flue down the chimney. The flue pull cone can then be retained for future installations * The 3D diagram to the left displays the key components of the Baxi Bermuda BBU HE. 1. Automatic Air Vent 2. Flue Connection 3. Spark Generator (located behind PCB) 4. Spark & Sensing Electrodes (located behind PCB) 5. Heat Exchanger (located behind PCB) 6. User Interface Connector 7. Control Wiring Connector 8. Condensate Sump 9. Gas Cock 10. Condensate Pump 11. Fan 12. Drain 13. Return Connection 14. Air Sampling Point 15. Flue Sampling Point 16. Flow Connection 17. Condensate Outlet 18. PCB Control Box 19. Boiler Control (cover open) 9

Flue Options Flue Options 1. Baxi Boilers can be fitted with flue systems as illustrated. 2. The standard flue is suitable only for horizontal termination applications. 3. Maximum permissible equivalent flue lengths for Platinum Combi HE A, Duo-tec Combi HE A, Megaflo system HE A are: Group A Group G Horizontal Concentric 10 metres 20 metres Vertical Concentric 10 metres 20 metres Horizontal Twin pipe 15 metres Vertical Twin Pipe 15 metres Maximum permissible equivalent flue lengths for Solo HE A are: Horizontal Concentric 4 metres Vertical Concentric 4 metres Horizontal Twin pipe 75 metres (parallel pipes) Vertical Twin Pipe 75 metres (parallel pipes) 4. Any additional in line bends in the flue system must be taken into consideration. Their equivalent lengths for Platinum Combi HE A, Duo-tec Combi HE A, Megaflo system HE A and Solo HE A are: Group A Group G Concentric Pipes 135 bend 0.5 metres 93 bend 1 metre The elbow supplied with the standard horizontal telescopic flue kit is not included in any equivalent length calculations for Platinum Combi HE A, Duo-tec Combi HE A, Megaflo system HE A are: Group A Group G Twin Flue Pipe 135 bend 0.25 metres 91.5 bend 0.50 metres The elbow supplied with the standard horizontal telescopic flue kit is not included in any equivalent lenth calculations for Solo HE are: Twin Flue Pipe 135 bend (air duct) 1.3 metres 135 bend (flue duct) 2.6 metres 91.5 bend (air duct) 4.8 metres 91.5 bend (flue duct) 9.6 metres The elbow supplied with the boiler is not included in any equivalent length calculations. 5. The illustrations show examples of permissible flue systems. 6. Instructions for guidance and fitting are included in each kit, where appropriate. GROUP A Concentric Horizontal Flue System 60/100mm diameter for use with Platinum Combi HE A, Duo-tec Combi HE A and Megaflo HE A Standard Horizontal Telescopic Flue inc Elbow 315mm - 500mm 60/100mm 5118069 Standard Horizontal Flue inc Elbow 685mm 60/100mm 5118489 Not illustrated Telescopic Internal Flue Kit 100mm 5119654 Flue Extension 1000mm 100mm 5111074 Flue Bend 93 degree 100mm 5111075 Flue Bend (Pair) 135 degree 100mm 5111085 Flue Bend 135 degree 100mm 5111076 Not illustrated Flue Internal Fixing Kit / Wall Liner 100mm 5111067 Not illustrated Pipe Support Painted white 100mm 5111080 Not illustrated Flue Terminal Deflector 60mm 5111068 Not illustrated Low Profile Flue Elbow 93 degree 100mm 720550801 NOTE: The 3 degree fall back on concentric flues can be reduced to 1.5 degree providing the flue system is adequately clamped in accordance with the installation instructions. GROUP A Concentric Vertical Flue System 60/100mm diameter for use with Platinum Combi HE A, Duo-tec Combi HE A and Megaflo HE A Vertical Flue Terminal 100mm 5118576 Flue Extension 1000mm 100mm 5111074 Flue Bend (Pair) 135 degree 100mm 5111085 Flue Bend 93 degree 100mm 5111075 Not illustrated Pipe Support Painted White 100mm 5111080 Pitched Roof Flashing 25/50 degree 125mm 5122151 Flat Roof Flashing 125mm 246144 Not illustrated Roof Cover Plate 125mm 246143 10

Flue Options GROUP B Concentric Horizontal Flue System 70/110mm diameter for use with Solo HE A Standard Horizontal Flue inc Elbow 850mm 110mm 236921 Horizontal Flue / Wall Terminal 850mm 110mm 243013BAX Vertical Flue Adaptor (Boiler) 110mm 5106888 Flue Extension 1000mm 110mm 241695 Flue Extension 500mm 110mm 241694 Flue Extension 250m 110mm 241692 Flue Bend 93 degree 110mm 241687 Flue Bend (Pair) 135 degree 110mm 241689 Not illustrated Pipe Support 110mm 243014BAX Not illustrated Flue Terminal Deflector 248167 NOTE: The 3 degree fall back on concentric flues can be reduced to 1.5 degree providing the flue system is adequately clamped in accordance with the installation instructions. GROUP B Concentric Vertical Flue System 70/110mm diameter for use with Solo HE A Vertical Roof Terminal 70/110mm 242802 Vertical Flue Adaptor (Boiler) 110mm 5106888 Flue Extension 1000mm 110mm 241695 Flue Extension 500mm 110mm 241694 Flue Extension 250m 110mm 241692 Flue Bend 93 degree 110mm 241687 Flue Bend (Pair) 135 degree 110mm 241689 Not illustrated Pipe Support 110mm 243014BAX Pitched Roof Flashing 25/50 degree 125mm 243015 Flat Roof Flashing 125mm 243016BAX Not illustrated Roof Cover Plate 243131 GROUP G Concentric Horizontal Flue System 80/125mm diameter for use with Platinum Combi HE A, Duo-tec Combi HE A and Megaflo HE A Horizontal Flue inc Boiler & Terminal Adaptor 125mm 5118580 Flue Extension 1000mm 125mm 5118584 Flue Bend 91.5 degree 125mm 5118588 Flue Bend (Pair) 135 degree 125mm 5118597 Not illustrated Pipe Support Painted white 125mm 5118610 11

Flue Options GROUP G Concentric Vertical Flue System 80/125mm diameter for use with Platinum Combi HE A, Duo-tec Combi HE A and Megaflo HE A Vertical Flue Terminal 125mm 5111078 Not illustrated Flue Vertical Adaptor 100/125mm 5111070 Flue Extension 1000mm 125mm 5118584 Flue Bend 91.5 degree 125mm 5118588 Flue Bend (Pair) 135 degree 125mm 5118597 Not illustrated Pipe Support 125mm 5118610 Pitched Roof Flashing 25/50 degree 125mm 5122151 Flat Roof Flashing 125mm 246144 Not illustrated Roof Cover Plate 125mm 246143 GROUP K Plume Displacement Kits 60/100mm diameter for use with Platinum Combi HE A, Duo-tec Combi HE A and Megaflo HE A Plume Displacement Kit inc Elbow & Clips 100mm 5118638 Plume Displacement Kit Extension inc Clip 1000mm 60mm 5121368 Plume Displacement Kit Bend 93 degree 60mm 5121369 Plume Displacement Kit Bend (Pair) 135 degree 60mm 5121370 GROUP L Plume Displacement Kits 70/110mm diameter for use with Solo HE A Plume Displacement Kit inc Elbow & Clips 110mm 5121371 Plume Displacement Kit Extension & Clip 1000mm 70mm 5121372 Plume Displacement Kit Bend 93 degree 70mm 5121373 Plume Displacement Kit Bend (Pair) 135 degree 70mm 5121374 12

Stockist: Available from all Heatmerchants branches nationwide Email: enquiries@heatmerchants.ie Warranty Support: Contact your local Heatmerchants branch for assistance Works Installer loyalty Scheme: Find out more on Works2gether.ie Potterton Myson Ireland Ltd. Unit F6, Calmount Park, Calmount Road, Ballymount, Dublin 12, Ireland T 00353 (0) 1 459 0870 F 00353 (0) 1 459 0880 E sales@potterton-myson.ie W www.potterton-myson.ie MYSON